Home
Enermax PRO82+ 625
Contents
1. CB report EMC CE EN61204 3 standard FCC MIC Temperature Humidity Efficiency Cooling Dear customer Thank you for choosing this ENERMAX PRO82 power supply unit PSU Please read this manual carefully and follow its instructions before installing the PSU CABLES amp CONNECTORS 385W amp 425W 525W amp 625W 20 4 P Mainboard in combined mode 7m 24 pin configuration supports 7 latest ATX BTX PC amp dual CPU ISS EEB CEB server workstation boards 20 4 P Mainboard in split mode 24P Mainboard 24 pin configuration supports latest ATX BTX PC amp dual CPU EEB CEB server workstation boards 20 pin configuration supports former ATX systems 4 4P CPU 12V in combined mode 8 pin configuration supports dual CPU server workstation systems and some single CPU PC systems 4 4P CPU 12V in split mode 4 pin configuration supports most ATX BTX systems Please use the connector with 12V marking 6 2P 8P PCI Express in combined mode 425 525 625W 8 pin configuration supports latest extreme graphic cards which require 8pin PCI E connector 6 2P 8P PCI Express in split mode 425 525 625W 6 pin configuration supports most performance PCI E graphic cards which require 6 pin PCI E connector 6P PCI Express 1 0 For most performance PCI Express graphic card which requires 6P PCI Express power connector Some SATA drives might accept SATA or 4P Molex power Normally use e
2. Precaution Notice Only a technician authorized by ENERMAX is allowed to perform maintenance service Warranty is subject to void under unauthorized attempt to open the power case or modification of any kinds even attempted only of the power supply or its components ENERMAX will not be responsible for damages caused by following situations Opening of the PSU case and or modification of any component or cable without ENERMAX written authorization Ignoring connector s wrong insertion prevention design by attaching a connector to a device in wrong orientation Connecting too many devices to one cable unit by using additional adaptor Y cables or exceeding ENERMAX Eternity connector recommendation which may cause voltage drop to the devices and eventually damage them Usage of non genuine ENERMAX modular cables Damage caused by natural phenomena or uncontrollable forces such as lightning flooding fire earthquake etc This ENERMAX Technology Corporation product is warranted to be free from defects in material and workmanship for a period of three 3 years from the date of purchase ENERMAX Technology Corporation agrees to repair or replace the product at its own option and at no charge if during the warranty period it is returned to nearest ENERMAX Technology Corporation subsidiary agent with all shipping charges prepaid and bearing a return merchandize authorization RMA number and if inspection reveals that t
3. ector 4 or 8 pin configuration and or a 4P Molex connector if required by MB is properly connected All other needed connectors are properly connected 3 4 AC cord is properly connected to wall plug and PSU AC inlet 5 Close your PC chassis 6 Turn on the power supply by switching the I O switch to T and your system is ready PROTECTION SAFETY amp SECURITY This ENERMAX PSU features multiple protections In case of most abnormal situations the power supply will automatically turn off to avoid potential danger to itself and other PC components It is usually a malfunction of components or user s negligence to trigger off a protection event In such circumstance please check your PC devices and working environment for malfunction 1 Turn I O switch of power supply into O position or disconnect AC cord from wall plug and power supply AC inlet 2 Check PSU for temperature by simply touching it If it is very hot this can be caused by malfunction of case fans or the PSU fan itself and or wrong positioning of your PC Wait some minutes until PSU cools off Reconnect AC cord to wall plug and power supply AC inlet Turn I O switch of power supply into I position and reboot your system Check if all fans are working ee Contact technical support of the respective manufacturer of the component which you think might be the cause to the problem e g MB GPU or PSU If you have any question or need supp
4. he product is defective Charges for removing or installing the product are excluded under the terms of this watranty agreement This warranty shall not apply to any product which has been subject to connection to a faulty power source alteration negligence or accident or to any product which has been installed other than in accordance with these instructions In no event shall ENERMAX Technology Corporation or its subsidiaries or agents be liable for damages for a breach of warranty in an amount exceeding the purchase price of this product If you are uncertain whether or not your ENERMAX PSU is defective please contact your dealer reseller for support Web Site http www enermax com E mail enermax enermax com tw 2008 ENERMAX Technology Corporation 15F 2 No 888 Jing Guo Road Taoyuan City 330 Taiwan R O C Tel 886 3 316 1675 Fax 886 3 346 6640 All rights reserved Actual product and accessories may differ from Illustrations Information in this manual is subject to change without prior notice Printing errors and omissions excepted All trademarks registered trademarks and or product names mentioned are the property of their respective owners Name of Parts 1 Output cable Please check Cables amp Connectors section 2 12cm fan 3 AC inlet 4 T O switch individual PSU on off switch I ON O OFF When assemble or maintain the system please remove AC cord from AC inlet or turn I O
5. ither SATA For SATA drives one of power connector to power the 4P Molex driver BUT NOT BOTH Please check For IDE SCSI drives or some AGP the drive s manual for details graphic card with traditional 4P power in socket FM FAN RPM MONITOR For 12cm fan RPM detection Normal fan speed for PRO82 is 450 2000RPM 410 COMPATIBILITY ENERMAX PRO872 series is compliant with E Intel ATX12V Power Supply Design Guide v2 3 specification and downward compatible with v2 0 v2 01 and v2 2 E ATX System Design Guide v2 2 v2 1 E BTX EEB CEB EPS12V This PSU does not support MB with ISA expansion slot which might require SV power 5V has been cancelled from Intel ATX12V v1 3 specification onwards To avoid failures and to increase lifetime of your entire PC we suggest you to make sure that E Your PC is NOT located near a radiator or any other heat producing device Your PC is NOT located near a magnetic device Y our PC is NOT located in a moist and or dusty and or vibrating environment Your PC is NOT exposed to direct sunshine Your PC is sufficiently cooled by additional fans We do not recommend using PC systems with fanless cooling because a potentially high inner temperature decreases stability and lifetime of all components inside your PC BOOTING YOUR SYSTEM Before booting your system please check that 1 Main power connector 20 or 24 pin configuration 1s properly connected 2 CPU 12V power conn
6. ort please contact your reseller or nearest ENERMAX subsidiary agent or ENERMAX headquarter service center Web Site http www enermax com E mail enermax enermax com tw Information in this document is subject to change without notice 2008 ENERMAX Technology Corporation All rights reserved Reproduction in any manner without the written permission of ENERMAX is strictly forbidden
7. switch into O position Specifications NS ca EPR385AWT EPR425AWT EPR525AWT EPR625AWT f AC 100 240 VAC 50 60Hz automatic adjustment active PFC P Max range 90 265VAC 6 2 5A 6 7 3A 7 5 3 5A 9 5 4A DC Output O J st comina ruei omines Rast Combined raea Combined ne a a a EN N ede 504 ee i Protection Circuits DC Rails Trigger Range 28 40A Over Current Protection sV 2840A 12V1 2 3 25 30A 385 425 W 30 35A 525 625 W DC Rails Trigger Range 3 7 4 1V Over Voltage Protection 57 65V 12V1 2 3 13 1 14 5V DC Rails Trigger Range DC Under Voltage 2 0 2 4V Protection 3 3 3 7V 5V 12V1 2 3 8 5 9 5V CO Diner Nolaee Activated when AC input voltage lt 80VAC Protection Over Power Protection Short Circuit Protection Over Temperature Protection Operation ambient 0 40 C 32 104 F for full rated output Storage ambient 40 70 C 40 158 F Operation to 85 relative humidity non condensing at 25 C 77 F Storage to 95 relative humidity non condensing at 50 C 122 F Power Factor gt 0 97 Active PFC 2 85 115VAC 84 88 230VAC 80 PLUS testing standard One 12cm fan 450 1500RPM 10 25 C ambient 450 2000RPM 10 40 C ambient speed auto controlled MTBF gt 100K hours under 70 of full rated load 230 VAC 50Hz input 25 C ambient MIL HDBK 217F standard Dimension Weight Safety UL cUL TUV BSMI CCC GOST
Download Pdf Manuals
Related Search
Related Contents
据付工事説明書 KeySonic KSK-8000 U Manual de instrucciones S 20 Mode d`emploi Entreprise Version 14 Builder's Choice HDX163740 Instructions / Assembly Bedienungsanleitung, Manuel, Operators manual optris CTratio BL20 – USER MANUAL ECO GATEWAY FOR EtherNet/IP™ Copyright © All rights reserved.
Failed to retrieve file