Home

Nortel Business Communications Manager 400, 48 User

image

Contents

1. Technical Bulletin Nortel Business Communications Manager 200 and Business Communications Manager 400 Technical Specifications Environmental specifications Operating temperature 32 to 104 F 0 to 40 C Operating humidity 10 to 90 relative humidity non condensing Storage temperature 67 to 158 F 55 to 70 C Storage humidity Up to 95 relative humidity Physical dimensions BCM400 BCM200 Depth 18 3 in 46 5 cm 18 3 in 46 5 cm Width 17 5 in 44 5 cm 17 5 in 44 5 cm Height 7 1 in 18 0 cm 3 5 in 9 0 cm Weight Std 35 2 Ibs Std 24 9 Ibs 15 9 Kg 11 3 Kg Redundant 46 7 Ibs 21 2 Kg Components BCM400 BCM200 Media Bay Module Bays Four Two CPU Processor Memory RAM Hard Drive Intel Celeron 1 2 GHz Intel Celeron 1 2 GHz 256 MB SDRAM 256 MB SDRAM 20 GB EIDE 20 GB EIDE System Status LEDs Power status Hard drive activity System status PCI device monitoring MSC WAN NIC 1 NIC 2 Chassis CPU temperature Fan activity _reset button The System Status Monitor Card controls and monitors fans power supply chassis temperature and OS status Mounting options Rack mount standard 19 inch rack Stand alone feet included Wall mount optional wall mount bracket available separately Power supply specifications Standard power supply Auto sensing Redundant power supply BCM400 only Auto sensing 300 Watts 350 Watts 90 264 VAC 90 264 VAC
2. group and national devi ations and CSA C22 2 No 60950 1 UL60950 1 e EU CTR12 13 3 4 21 EN 60950 with national deviations e United Kingdom EN60950 Telephony components Media Services Card BCM MSC e One 8 pin modular jack RJ 45 connection for Expansion Chassis Only on BCM400 not BCM200 e Four 3 5 mm 1 8 inch standard miniature stereo 3 conductor Safety Extra Low e Voltage SELV jacks for auxiliary ringer page relay page output and music on hold e Auxiliary ringer switch capacity of 50mA non inductive at 40 V maximum e 24 B channels with T1 interface supports DSX 1 and DS1 interfaces e LEDs Power Status In service Loop back Test Receive Alarm Receive Error Transmit Alarm Transmit Error e LEDs Transmit Receive RTS CTS DCD DSR TM e V 35 DB26 miniature connector e Cables V 35 BCM WAN Nortel Routers DB 60 cable e Utilizes two DS 30s Basic Rate Interface Media Bay Module BRIM S T e Four modular RJ 45 jacks e Supports four S T interfaces 8 B channels e T interface to connect to an NT1 device or an S interface to connect ISDN terminals e Supports ETSI and National ISDN BRI e Two LEDs Power Status e Utilizes 1 3 DS 30 Global Analog Trunk Module GATM 4 e One Amphenol male connector for analog North American UK and Australia Standard e Page Relay switch capacity of 50mA non inductive at 40 V maximum e F
3. with RJ 45 connector 10 100 Auto sensing e Full duplex support e PPPoE enabled using keycode Two port PCI card field installable e Each port can be independently configured to Frame Relay or PPP e STAC compression support e One serial sync port V 35 and one T1 port with integrated CSU and DSU connectivity N A only e Two serial ports V 35 e Two serial ports V 35 and X 21 EMEA only e Frame Relay or PPP Fragmentation e RTP Header Compression ISDN via MBMs e Up to 16 ISDN B channels e PRI or BRI optional e Dial on demand Persistent or WAN Backup e MLPPP Expansion Cabinet BCM400 and BCM1000 only e Six Media Bay Module slots e An 8 pin modular DS256 connector for the interface to the Business Communications Manager base unit 5 meter cable Depth 18 3 in 46 5 cm Width 17 5 in 44 5 cm Height 5 4 in 13 6 cm Expansion Cabinet with no Media Bay Modules 24 75 Ib 11 25 kg Expansion Cabinet with six Media Bay Modules 39 Ib 17 75 kg Depth 20 in 53 8 cm Width 17 6 in 44 6 cm Height 5 4 in 13 6 cm Expansion Cabinet with no Media Bay Modules 31 9 Ib 14 5 kg Expansion Cabinet with 6 Media Bay Modules 46 2 Ib 21 kg Standard Power Supply Auto sensing Redundant Power Supply Auto sensing 32 to 104 F 0 to 40 C 10 to 90 relative humidity non condensing 67 to 158 F 55 to 7
4. 0 C Up to 95 relative humidity Operating temperature Operating humidity Storage temperature Storage humidity Rack mount standard 19 inch rack Stand alone feet included Wall mount optional wall mount bracket available separately Telephones and Adapters Business Series North Dimensions Loop Length With SAPS America Inches 26G sets T7100 8 1D x 7Wx3 5H 1 000 ft 2 600 ft T7208 8 1D x 7 7Wx3 5H 1 000 ft 2 600 ft T7316E 8 1D x 10 3Wx3 5H 1 000 ft 2 600 ft T24 KIM 7 7D x 3 6Wx3 4H Connects to T7316E NACU 12 5 x 12Wx2H 1 000 ft 2 600 ft e Nortel IP Phone 1120E e Nortel IP Phone 1140E e Nortel IP Phone 2007 e Nortel IP Phone 2004 e Nortel IP Phone 2002 e Nortel IP Phone 2001 e Nortel IP Phone 2033 e Nortel IP Softphone 2050 PC or Laptop T24 EKIM Enhanced KIM used as CAP max 12 positions per system max 4 EKIMs per position T24 OKIM Ordinary KIM used for answer DSS BLF unlimited per system max 4 OKIMs without power supply per position max 9 OKIMs with power supply per position e WLAN Handset 2210 e WLAN Handset 2211 e WLAN Handset 2212 e WLAN IP Telephony Manager 2245 e WLAN Applications Gateway 2246 e Nortel Mobile Voice Client 2050 e Digital Mobility Controller e Digital Mobility Basestation e Digital Mobility Repeater e Digital Mobility Handsets 7420 743x 744x 413x 414x T7406 3 handsets pe
5. 1 800 466 7835 from anywhere in North America Nortel the Nortel logo Nortel Business Made Simple and the Globemark are trade marks of Nortel Networks All other trademarks are the property of their owners Copyright 2007 Nortel Networks All rights reserved Information in this document is subject to change without notice Nortel assumes no responsibility for any errors that may appear in this document FACOLTA UON O0 TA VADO VUN MAN NN111380 022607 NORTEL gt BUSINESS MADE SIMPLE
6. 6 0 A 3 0 A 7 0 A 3 5 A 60 50 Hz 60 50 Hz Mechanical requirements NEBS GR 63 CORE compliant for Transportation and Operational Vibration per IEC 68 2 27 Package Drop Shock resistance per ISTA 1A Transportation Bounce to IEC 68 2 55 and Unpackaged Drop to ISTA Project 1A Regulatory compliance Electromagnetic emissions Radiated Air Australia AS3548 Class A North America CISPR22 Class A United Kingdom EN55022 Class A Conducted Power Leads Australia AS3548 Class A North America CISPR22 Class A United Kingdom EN55022 Class A Immunity Narrow band RF interference Radiated North America customer driven based on EN 61000 4 3 United Kingdom International EN55024 1998 Conducted North America customer driven Based on EN 61000 4 6 United Kingdom International EN55024 1998 Immunity to electrostatic discharge Indirect No functional impairment up to 8 kV Direct Mated I O ports and connectors No damage up to 4 kV Mated connector and cords No functional impairment up to 8 kV No damage up to 15 kV Network protection e Australia TS038 31 03 04 01 Digital Drop and Insert MUX Media Bay Module DDIM e One 8 pin RJ 45C modular jack e EU CTR12 13 3 4 21 e T1 trunk interface with integrated CSU e North America CALA FCC Part 68 CS 03 Issue 8 Safety and surge transient e Australia TS038 31 02 03 04 ACA TSOO1 AS NZS 3260 e NA CALA APAC IEC EN 6095041 including all
7. nection or Power Fail Transfer e One Amphenol male connector 25 pair to support 16 digital phone ports e Individual Station interfaces are current limited to 80mA e Two LEDs Power Status e Utilizes 11 4 DS 30s Global 8X16 Module 8 Caller ID trunks 16 Station Sets G8X16 e One Amphenol male connector 25 pair to support eight loop start CLASS CMS lines plus one auxiliary port for V 90 modem fax analog telephone connection or Power Fair Transfer e One Amphenol male connector 25 pair to support 16 digital phone ports e Individual Station interfaces are current limited to 80mA e Two LEDs Power Status e Utilizes 11 2 DS 30s ADID Module Analog Direct Inward Dial 4 Port or 8 Port ADID4 and ADID8 e One Amphenol male connector 25 pair to support four or eight ADID lines e Two LEDs Power Status e Utilizes 1 4 DS 30 ADID4 or 1 2 DS 30 ADID8 e Currently North America DID standard Embedded v 92 Modem e For Dial Backup or Remote Admin e V 92 56 kbps ITU standard e V 34 33 6 kbps ITU standard e RJ 11 connector e V 42 MNP 2 4 error control e V 42 MNP 5 data compression e Capable of receiving data at 56 kbps and sending data at 31 2 kbps 10 100 Ethernet LAN interface 10 100BASE T Ethernet ports on board the mainboard e Supports IEEE 802 3 Ethernet frame format e Uses Carrier Sense Multiple Access with Collision Detection CSMA CD e 100BASE TX
8. our loop start CLASS CMS lines plus one auxiliary port for V 90 modem fax analog telephone connection or Power Fail Transfer e Page Output 600 ohms impedance e Two LEDs Power Status e Music on hold mono input e Media Services Processor Expansion Card slots BCM400 four slots two equipped BCM200 two slots one equipped e Supports maximum of 8 DS 30s Allows 2 6 and 3 5 IP TDM Splits 16 Stn Digital Station Media Bay Module DSM 16 e One Amphenol male connector 25 pair e Individual interfaces are current connector 25 pair limited to 80 mA e16 digital phone ports e Utilizes 1 4 DS 30 Global Analog Trunk Module GATM 8 e One Amphenol male connector for analog North American UK and Australia Standard e Eight loop start CLASS CMS lines plus one auxiliary port for V 90 modem fax analog telephone connection or Power Fail Transfer e Two LEDs Power Status e Utilizes 1 2 DS 30 Fiber Expansion Media Bay Module FEM e Six fiber ports e Two LEDs Power Status e Connects up to six Norstar fiber based trunk or station modules e Utilizes 1 2 DS 30 with DIP switch set appropriately 32 Stn Digital Station Media Bay Module DSM 32 e Two Amphenol male e Individual interfaces are current connectors 25 pair limited to 80 mA e 32 digital phone ports e Two LEDs Power Status e Utilizes 1 DS 30 with DIP switch set appropriatel
9. r basestation 2 basestations per system BST Doorphone Norstar Audio Conferencing Unit NACU Station Auxiliary Power Supply SAPS 300 Watts 350 Watts ATA 2 Analog Terminal Adapter separate models for NA Europe 90 264 VAC 90 264 VAC and Australia 6 0 A 3 0 A 7 0 A 3 5 A 60 50 Hz 60 50 Hz In the United States In Europe Nortel Nortel 35 Davis Drive Maidenhead Office Park Westacott Way Research Triangle Park NC 27709 USA In Canada Nortel 195 The West Mall Toronto Ontario M9C 5K1 Canada In Caribbean and Latin America Maidenhead Berkshire SL6 3QH UK In Asia Nortel United Square 101 Thomson Road Singapore 307591 Phone 65 6287 2877 Nortel 1500 Concorde Terrace Sunrise FL 33323 USA Nortel is a recognized leader in delivering communications capabilities that enhance the human experience ignite and power global commerce and secure and protect the world s most critical information Our next generation technologies for both service providers and enterprises span access and core networks support multimedia and business critical applications and help eliminate today s barriers to efficiency speed and performance by simplifying networks and connecting people with infor mation Nortel does business in more than 150 countries For more information visit Nortel on the Web at www nortel com For more information contact your Nortel representative or call 1 800 4 NORTEL or
10. y 8 Stn Analog Station Media Bay Module GASM 8 e One Amphenol male connector 25 pair e Maximum modem connection speed 28 8 kbps e 8 analog phone ports e Loop length 26G 2600 ft 24G 4000 ft 22G 6500 ft e Disconnect Supervision 850 ms Momentary Disconnect Open Switch Interval OSI as per TIA EIA 464 e Message Waiting Indication NA 120V 600 ms On and 1000 ms Off UK reverse polarity e Analog connectivity support for Poland and Australia e Calling Line Identification CLID Name and Number NA per Bell 202 standard UK per SIN 227 224 e Two LEDs Power Status e Utilizes 1 4 DS 30 with DIP switch set appropriately Digital Trunk Media Bay Module DTM e One 8 pin RJ 45C modular jack e T1 trunk interface with integrated CSU e 24 B channels with T1 interface supports DSX 1 and DS1 interfaces e 23 B channels with North American PRI interface e LEDs Power Status In service Loop back Test Receive Alarm Receive Error Transmit Alarm Transmit Error e 30 digital channels with ETSI PRI Interface e Utilizes 1 one DS 30 e Two LEDs Power Status e Utilizes 1 DS 30 for each Norstar fiber trunk or station module connected up to 6 Global 4X16 Module 4 Caller ID trunks 16 Station sets G4x16 e One Amphenol male connector 25 pair to support four loop start CLASS CMS lines plus one auxiliary port for V 90 modem fax analog telephone con