1. 4U profile 24 bay FC 2G to SATA II RAID Subsystem EonStor A24F G2224 i The A24F G2224 subsystem comes with two 2 2Gb per second Gbps Fibre channels interfaced through eight 8 SFP ports on two 2 independent I O modules with embedded bypass Thesubsystem s 4U profile rack mountable chassis houses RAID controller featuring complete RAID protection and data integrity functionality All major components are hot replaceable including its Li ION battery host I O modules and the RAID protected disk drives The subsystem provides high density array capacity with twenty four 24 drive bays for SATA II disk drives facilitates large I O transfer over its dual PCI X bus architecture and transmits block I Os over flexible caching and the dedicated RAID 6 engine The A24F combines the capabilities and block level performance of RAID storage with reliable Fibre Channel connectivity Infortrend www infortrend com Reliable Storage Based ona proven architecture designed for continuous operation with heavy access loads the EonStor A24F G2224 is ideal for environments from SAN attached storage to performance intensive applications operating within an open system and multi path framework This SAN ready subsystem meets the demands for enterprise class storagein terms of its reliable firmware ease of management fault proof hardware and on the fly scalability W Highlights e Two 2 2Gbps
2. DB9 female to DB9 male wires swapped RS 232C serial cable audio jack toDB9 for A24F G2224 single controller Agilent Fibre Channel 2 125 1 0625 GBd Small Form Pluggable Optical Transceiver LC wave length 850nm multi mode Optical FC cable LC LC MM 62 5 125 Duplex LSZH O D 1 8mmx2 1 Meter Optical FC cable LC LC MM 62 5 125 Duplex LSZH O D 1 8mmx2 5 Meters Optical FC cable LC LC MM 62 5 125 Duplex LSZH O D 1 8mmx2 10 Meters Dummy drive tray Type II bezel RS 232C serial cableand audio jack to DB9 cable for UPSstatus monitoring Slide rails for 24 to 32 deep racks Slide rails for 24 to 36 deep racks Part Number IFT 84AF22RD24E IFT 9274CD Tray IFT 9274A2DT2S1S IFT 9274A2N2S1S i927 4CP5U IFT 9274CFanMod IFT 9274CF2HIO4L IFT 9274CF2HIO4R IFT 9274HandLLCD IFT 9274CHandR IREO 27 4Cbi IFT DDRESCM5 IFT DDRESCMA IFT DDRESCMB Part Number IFT 9011 IFT 9270ASCab IFT 9270CSFP2GA01 IFT 9270CFCCab01 IFT 9270CFCCab02 IFT 9270CFCCab03 IFT 9272CDTrayDmy IFT 9270CUPSCab IFT 9274Cslider32 IFT 9274Cslider36 www infortrend com China Infortrend Technology Ltd Room 1210 West Wing Tower One Asia Pacific Infortrend Technology Inc 8F No 102 Chung Shan Rd Sec 3 Chung Ho City Taipei Hsien Taiwan Tel 886 2 2226 0126 Fax 886 2 2226 0020 sales infortrend com tw support infortrend com tw http www infortrend com tw Americas Infortrend Corporation 3150
3. 86 x 19 6 inches www infortr nd com Infortrend products are used in Mi Major Markets and Uses disk to disk backup server attached and network data storage and in major industries such as medical imaging security CCTV and digital media including Reliable Storage Networking Solution Provider video on demand stream editing and more Mi Spare Parts Description Fibre to SATARAID controller module for ES A24F G2224 subsystems noFC 2G SFP host connectors RAID6 Drive tray Type III bezel w maizecolor push buttonand Type II LED lightpipe Drive tray Type III bezel andType IILED lightpipe 2 to 1 SATA SATAII MUX conversion power MOS switch embedded HDD 2 to 1 SATA SATA II MUX conversion SCA II to SATA power MOSswitch embedded single controller subsystems Power supply module ES 4U 24 bay subsystems 405W N 1 capacity Dual fan cooling modulein a hot swappable canister Fibre Channel FG2G I O board left hand side for ES 4U 24 bay subsystems 4 xSFP ports w onboard host hub Fibre Channel FG 2G I O board right hand side for ES 4U 24 bay subsystems 4 xSFP ports w onboard host hub Left side forearm handle with anLCD panel Right side forearm handle Battery cell pack Li ION forES 4U 24 bay subsystems 512MB DDR RAMDIMM module forall EonStor subsystems 1GB DDR RAMDIMM module forall EonStor subsystems 2GB DDR RAMDIMM module forall EonStor subsystems MM Accessories Description Null modem
4. per controller 1 Diagnostic LEDs on all FRUs Drive Interface Redundant and hot swappable FRUs System self diagnostics Dedicated and Global hot spare Li ION battery backup module UPS support Management Software RAIDWatch Manager software Terminal via RS 232C Telnet over Ethernet LCD keypad panel Event notification methods Number of disktrays a4 Email Serial ATA II I drive support ae Fax LAN broadcast SNMP traps Maci Unien aas Cell phone message SMS 2Gbps SFP ports 8 Single channel bandwidth Tag command queuing Multiple target IDs RAID Configurations RAID levels 0 1 0 1 3 5 6 10 30 50 60 JBOD Max 32 logical drives Max 1024 LUNs Multiple array configurations Automatic background rebuild Intelligent drive handling 200MBps Instant messages MSN ICQ OS Support Microsoft Windows NT Microsoft Windows 2000 Server Microsoft Windows 2003 Server Sun Solaris ver 8 9 Red Hat Linuxver 8 9 Enterprise ver 3 SUSE Linux ver 8 9 Input Voltage 9OAC at8A 264VAC at4A with PFC auto switching DC Ouisur 12V 24A 5V 36A 3 3V 20A Relative Humidity 5 to 95 non condensing Operating Temperature 0 C to 40 C Dimensions 4U 19 inch rackmount chassis Chassis with handles AAT VN Vex 174 4 H x 514 D mm 17 6 x 6 86 x 20 2 inches Chassis without handles 482 W x 174 4 H x 498 D mm 18 9 x 6
5. Coronado Dr Unit C Santa Clara CA 95054 USA Tel 1 408 988 5088 Fax 1 408 988 6288 sales infortrend com tsd infortrend com http www infortrend com Tel 86 10 63106168 Fax 86 10 63106188 sales infortrend com cn support infortrend com cn http www infortrend com cn Copyright 2005 by Infortrend Technology Inc All rights reserved Any information provided herein is without warranties of any kind and is subject to change by Infortrend without prior notice Infortrend offers a 3 year limited warranty on subsystems and a 1 year warranty on battery backup units FIBRE CHANNEL INDUSTRY ASSOCIATION ad X SNA EGIA k Junefield Plaza No 6 Xuanwumen Street Xuanwu District Beijing China 100052 gXICATION o S F r 3 Cc e a Japan Infortrend Japan Inc 6F Okayasu Bldg 1 7 14 Shibaura Minato ku Tokyo 105 0023 Japan TEL 81 3 5730 6551 FAX 81 3 5730 6552 sales infortrend co jp support infortrend co jp http www infortrend co jp ANo oo LISTED T E 42AG cB S D33225 Europe Infortrend Europe Ltd 5 Elmwood Crockford Lane Chineham Business Park Basingstoke Hampshire RG24 8WG UK Tel 44 1256 70 77 00 Fax 44 1256 70 78 89 sales infortrend europe com support infortrend europe com http www infortrend europe com Infortrend and the Infortrend logo are registered trademarks of Infortrend Technology Inc EonStor and RAIDWatch are registered trademarks of Infort
6. ahard disk drive power supply battery module or cooling fan can be replaced within seconds The modules are closely monitored using self diagnostic features and the help of runtime utilities such as RAIDWatch Spring screws securing latches and key locks all provide easier access to the modules A variety of configuration and monitoring methods are available either locally via the LCD keypad panel and the text mode RS 232C terminal or remotely through the Java based GUI manager All faulty conditions including RAID configuration events module failure voltage and temperature readings are instantly reported Asystem administrator can select from the following notification methods to receive reports when away fromthe installation site LAN broadcast SNMP traps email fax SMS ICQ and MSN Messenger Even the notification utility can be installed redundantly on two different machines to avoid the chance of blind time www infortrend com W Infortrend Smart Technologies Derived from more than ten years of experience in RAID storage design Infortrend s firmware features extremely compact protocol and rich varieties of algorithms to deal with the stringent requirements of storage applications The technologies enhance I O processing drive handling and system management TOSmart The IOSmart technologies consist of specific functions and configuration options that control various I O characteristics inorder to meet the ra
7. bypass embedded Fibre host channels Separate I O board Max 8 host connection Supports 3Gbps SATA II disk drives backward compatible with SATA I disk drives End to end performance up to 385MBps for Sequential Reads and 315MBps for Sequential Writes in a RAID5 array Supports up to2GB DDR RAM e Supports RAID level 6 Modular passive backplane in ahigh availability architecture Highest density 4U chassis providing up to 12TBof storage capacity Optional hot swappable battery backup units BBUs Dual speed cooling fans to reducesystem noise and power consumption Ease of managementthrough an LCD keypad panel RS 232C terminal oran Ethernet link TCP IP toa PC running Java based RAIDWatch Manager e Real time event notification by various methods W Reliability In addition to RAID protection against drive failure the subsystem has ingenious means to deal with other challenges that may jeopardize data integrity For example hard disks wear down over time and drives may arrive from the manufacturer with inherent defects MediaScan and Task Scheduler are among the DrvSmart utilities designed to detect and mend these problems The subsystem is also equipped with error containment algorithms known as the SysSmart functions If a critical component fails e g a cooling module the subsystem automatically disables write back caching and assumes the conservative write through mode If the fault condition persists f
8. or an extended period of time the subsystem enters an idle state Allof these precautions help ensure safe operation and data integrity Networking Solution Provider MB Availability The EonStor A24F is powered by field proven technologies that ensure data protection and performance to meet various storage needs Data is secured by sophisticated components and advanced firmware developed through a decade of experience in RAID technology In addition to the choice of RAID levels 0 1 0 1 3 5 6 10 30 50 and60 the subsystem protects your data with various high availability algorithms ranging from predictive checking and self healing rebuilds to system self diagnostics Toensure ahigh level of availability critical components such as disk drives power supplies and cooling fans are all redundant and hot swappable Modules are integrated with the passive backplane via board to board connectors to eliminate points of failure Assisted by GUI management software system administrators can constantly monitor the operating status of all components through aconsole locally or remotely situated The subsystem guarantees data integrity with selected high MTBF components a modular fault tolerant design anda complete set of environmental monitoring and fault protection capabilities built inthe firmware MB Serviceability All critical modules are housed in separate easily retrievable canisters In the event of component failure
9. pidly increasing requirements of today s applications These functions include adaptable stripe size write policy optimizations modes Guaranteed Latency I O and automatically adjusted multi threaded predictive read ahead sorted or group writes Subsystem Characteristics High Availability Reliable Storage Networking Solution Provider DrvSmart DrvSmart is comprised of fault preventive algorithms that ensure data integrity when hard drive imperfections occur These mechanisms correct minor defects increase reaction time allow more time to prepare a rebuild and help minimize performance impact DrvSmart functions include Media Scan and Task Scheduler hot spare drive roaming SMART and manual cloning options and more SysSmart SysSmart combines enclosure monitoring and firmware management capabilities designedto minimize the chance of downtime caused by hardware failures With SysSmart Infortrend s subsystems are smartly managed and guarded against extreme operating conditions SysSmart functions include the event triggered adaptive write policy auto shutdown dual speed fan control and the various monitoring utilities and approaches included in the powerful RAIDWatch Manager software Specifications Requirements 600MHz RISC CPU 512KB L2 cache ASIC266 RAID engine DDR cache memory 512MB BBUs percontroller optional 1 LCD keypad panel Serial COM ports per controller 2 Ethernet ports
10. rend Technology Inc All other names brands products or services are trademarks or registered trademarks of their respective owners Nov 2005