Home

3com 3Com® TP Transceiver Interface Module

image

Contents

1. LIMITED WARRANTY HARDWARE 3Com Limited 3Com warrants its hardware products to be free from defects in workmanship and materials under normal use and service for the following lengths of time from the date of purchase from 3Com or its Authorized Reseller Internetworking products One year Ethernet Stackable Hubs and Unmanaged Ethernet Fixed Port Repeaters Lifetime One Year if not registered Power supply and fans in these stackable hubs and unmanaged repeaters One Year Other hardware products One year Spare parts and spares kits 90 days If a product does not operate as warranted during the applicable warranty period 3Com shall at its option and expense repair the defective product or part deliver to Customer an equivalent product or part to replace the defective item or refund to Customer the purchase price paid for the defective product All products that are replaced will become the property of 3Com Replacement products may be new or reconditioned Any replaced or repaired product or part has a ninety 90 day warranty or the remainder of the initial warranty period whichever is longer 3Com shall not be responsible for any software firmware information or memory data of Customer contained in stored on or integrated with any products returned to 3Com pursuant to any warranty SOFTWARE 3Com warrants that the software programs licensed from it will perform in substantial conformance to the program specifi
2. the header pins facing down See Figure 1 to locate the header pins Pass the board of the Transceiver Module through the cut out in the front panel Align the socket on the Module with the pins on the Transceiver Module and push down firmly to connect With the 3C18146 Expansion Module you align the header and pins and press gently to engage the pins Turn the pair over to rest on the Transceiver Module and press firmly close to the header to complete connection Fix the mounting panel of the Transceiver Module to the module using the two screws from the blanking plate Connection Before proceeding with the installation of the module check that the host equipment is set up to take the module See the relevant How to Install and Use manual Re install the mother device into its chassis and or network Connect the Transceiver Module to the TP segment 4 Operation Link LED The Link LED on the front of the Transceiver Module lights green when a link is detected If a link is not present the LED does not light Standards The 3Com RJ45 Transceiver Module 3C12063 has been designed to comply with the following standards Functional PLS amp AUI Specification ISO 8802 3 Sect 7 amp 10 Safety UL 1950 EN 60950 CSA 22 2 950 E M C FCC Part 15 Level A EN55022 Level A VFG 243 Level B IEC 801 Parts 2 6 Environment IEC68 Operating Temperature 0 to 50 C 32 to 122 F Humidi
3. Y OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE OR BY ACCIDENT FIRE LIGHTNING OR OTHER HAZARD LIMITATION OF LIABILITY IN No EVENT WHETHER BASED IN CONTRACT OR TORT INCLUDING NEGLIGENCE SHALL 3COM BE LIABLE FOR INCIDENTAL CONSEQUENTIAL INDIRECT SPECIAL OR PUNITIVE DAMAGES OF ANY KIND OR FOR LOSS OF REVENUE LOSS OF BUSINESS OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE USE PERFORMANCE FAILURE OR INTERRUPTION OF ITS PRODUCTS EVEN IF 3COM OR ITS AUTHORIZED RESELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES NOTHING HEREIN SHALL HAVE THE EFFECT OF LIMITING OR EXCLUDING 3COM S LIABILITY FOR DEATH OR PERSONAL INJURY CAUSED BY NEGLIGENCE Some states do not allow the exclusion of implied warranties or the limitation of incidental or consequential damages for consumer products so the above limitations and exclusions may not apply to you This warranty gives you specific legal rights which may vary from state to state Nothing in this warranty shall be taken to affect your statutory rights GOVERNING LAW This Limited Warranty shall be governed by the laws of England 3Com Limited ISOLAN House Brindley Way London Road Hemel Hempstead Hertfordshire HP3 9XJ UK 44 0 442 278000 23 12 93 Page 4 How To Install And Use The TP Transceiver Interface Module 3012063 LinkBuilder This manual details the installation and use of the 3Com TP Transceiver Interf
4. ace Module 3C12063 Please retain this manual with your other 3Com manuals for future use SQE Test Edge Connector Jumper PL1 4 PL2 is ig H s Link LED 7 MDI MDIX Pin Header Jumper s Figure 1 1 Interworking Information The 3Com LinkBuilder TP Transceiver Interface Module has been designed to the IEEE 802 3 10BaseT specification The Transceiver Module can transmit and receive Ethernet 10 Mbit sec traffic over Shielded or Unshielded Twisted Pair cable The Transceiver Module features crossover MDI MDIX switching SQE Test selection and link monitoring using the Link LED Light Emitting Diode The Transceiver Module is used to provide connectivity to twisted pair cable on the following LinkBuilder products e ECS modules 3C12076 and 3C12050 1 e MSH modules 3C18110 3C18120 3C18124 3C18146 and 3C18600 e FMS Stackable Hubs 3C16250 3C16265 3C16271 and 3C16371 e FMSII Stackable Hubs 3C16665 3C16670 3C16671 and 3C16672 LinkBuilder TP 12 3C16170 and LinkBuilder TP 8i 3C16181 hubs Repeaters 3C16170 3C16200 3C16210 and 3C16505 This product has the benefit of a lifetime warranty details of which are given on page 4 of this manual 2 Setting up the Module MDI MDIXx The PL2 component switches the TP port between MDI and MDIX MDI is the default setting and allows the Transceiver Module to be connec
5. aratus ICES 003 of the Department of Communications Cet appareil num rique respecte les limites de bruits radio lectriques applicables aux appareils num riques de Classe A prescrites dans la norme sur le mat riel brouilleur Appareils Num riques NMB 003 dict e par le ministre des Communications 3Com and LinkBuilder are registered trademarks of the 3Com Corporation Document No DUA1206 3AAA01 Revision 00 Issued November 1994 3 1994 3Com Technologies Limited Page 3
6. cations therefor for a period of ninety 90 days from the date of purchase from 3Com or its Authorized Reseller 3Com warrants the magnetic media containing software against failure during the warranty period No updates are provided 3Com s sole obligation hereunder shall be at 3Com s discretion to refund the purchase price paid by Customer for any defective software products or to replace any defective media with software which substantially conforms to 3Com s applicable published specifications Customer assumes responsibility for the selection of the appropriate applications program and associated reference materials 3Com makes no warranty that its software products will work in combination with any hardware or applications software products provided by third parties that the operation of the software products will be uninterrupted or error free or that all defects in the software products will be corrected For any third party products listed in the 3Com software product documentation or specifications as being compatible 3Com will make reasonable efforts to provide compatibility except where the non compatibility is caused by a bug or defect in the third party s product STANDARD WARRANTY SERVICE standard warranty service for hardware products may be obtained by delivering the defective product accompanied by a copy of the dated proof of purchase to 3Com s Service Center or to an Authorized 3Com Service Center during the applicabl
7. e warranty period Standard warranty service for software products may be obtained by telephoning 3Com s Service Center or an Authorized 3Com Service Center within the warranty period Products returned to 3Com s Service Center must be pre authorized by 3Com with a Return Material Authorization RMA number marked on the outside of the package and sent prepaid insured and packaged appropriately for safe shipment The repaired or replaced item will be shipped to Customer at 3Com s expense not later than thirty 30 days after receipt by 3Com WARRANTIES EXCLUSIVE IF A 3COM PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY SHALL BE REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT 3COM S OPTION THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES OR CONDITIONS EXPRESS OR IMPLIED EITHER IN FACT OR BY OPERATION OF LAW STATUTORY OR OTHERWISE INCLUDING WARRANTIES OR CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE 3COM NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE OR USE OF ITS PRODUCTS 3COM SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER S OR ANY THIRD PERSON S MISUSE NEGLECT IMPROPER INSTALLATION OR TESTING UNAUTHORIZED ATTEMPTS TO REPAIR OR AN
8. r cable can be connected to the RJ45 connector on the front of the Transceiver Module Remove the blanking plate from the unit in which you are going to install the Transceiver Module The relevant manual will tell you where to find the plate Keep the blanking plate in a safe place so that it can be replaced if the Transceiver Module is removed Page 2 Installing in a Stackable Hub or Repeater For FMS Stackables and Repeaters hold the mounting panel with the pin header side of the board down See Figure 1 to locate the pin header For FMS II Stackables hold the mounting panel with the pin header side of the board up Insert the edge connector end of the Transceiver Module into the rear of the mother device Slide the Transceiver Module in carefully to engage in the slot and push it fully home Fix the mounting panel of the Transceiver Module to the back panel using the two screws from the blanking plate Installing in an ECS or MSH Module Before you install the Transceiver Module you must remove the mother device from the network and all power sources Modules must be removed from the Chassis you do not need to power down the chassis first The 3C18146 Expansion Module must be separated from its mother module See the relevant How to Install and Use manual Position the Module on a flat surface with the 16 way socket facing up Hold the Transceiver Module by the mounting panel and board edge with
9. ted by normal twisted pair cable to an MDIX port on another hub to form an inter repeater link If MDIX is selected the Transceiver Module can be connected to a workstation or any other Data Terminal Equipment It can also be connected to another hub which is already set to MDI to form an inter repeater link See Figure 1 to locate the MDI MDIX jumper and then Figure 2 to ensure you have the correct selection PL2 PL2 cocco eocce MDIX MDI Selected Selected default Figure 2 Page 1 SQE Test The PL1 component allows you to enable or disable the SQE Test The SQE Test is used by 802 3 transceivers to confirm that the transceiver is functioning correctly The function must be disabled for operation when installed in a Repeater The function should be enabled for operation when connected to a LinkBuilder ECS Local Bridge Module 3C12050 1 The Transceiver Module is supplied with SQE Test disabled See Figure 1 to locate the SQE Test jumper and then Figure 3 to ensure you have the correct selection PL1 PL1 SQE Test SQE Test Disabled Enabled Figure 3 3 Installation Only qualified personnel should install this device Observe normal anti static precautions Use an earthed wrist band A 16 pin header and a 16 way edge connector are mounted on the Transceiver Module for connection to a Module Stackable Hub or Repeater A Twisted Pai
10. ty 10 to 90 Non Cond 5 Problems If the Link LED does not light when the Transceiver Module is installed the cause may be one of the following Both ends of the link are configured as MDI change one to MDIX Both ends of the link are configured as MDIX change one to MDI The far end device is not powered up or may be faulty Check the device The cable linking the devices is broken or incorrectly wired Change the cable Disclaimer Information in this document is subject to change without notice and does not represent a commitment on the part of 3Com 3Com reserves the right to revise or change this document without obligation of 3Com to notify any person of the revisions or changes Information contained in this document is believed to be accurate at the time of publication but no liability whatsoever can be accepted by 3Com arising out of any use of this information Radio Frequency Interference Statement This equipment has been tested with a class A computing device and has been found to comply with part 15 of FCC Rules Operation in a residential area may cause unacceptable interference to radio and TV receptions requiring the operator to take whatever steps are necessary to correct the interference This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the interference causing equipment standard entitled Digital App

Download Pdf Manuals

image

Related Search

Related Contents

Istruzioni per l`uso Logamatic SC300  ISR 12-LO / IGAR 12-LO - Mid  Visor Alarm    NannyMUD LPC  Biopac Student Lab Catalog  PARTS AND SERVICE MANUAL  DesignWare IP Family Reference Guide  janvier 2015 - Centre de Ressources Autisme  Development Manual - Tinovimba G. Motsi  

Copyright © All rights reserved.
Failed to retrieve file