Home

Rangemaster LEIHDC70BB cooker hood

image

Contents

1. LEIHDC70SC LEIHDC70BB LEIHDC70BC Instructions Manual www rangemaster co uk INDEX RECOMMENDATIONSANDSUGGESTIONS erro 3 CHARACTERISTIC n M 4 INSTALLATION ee A 5 lolum d DN ME 8 RECOMMENDATIONS AND SUGGESTIONS NThe Instructions for Use apply to several versions of this appliance Accord ingly you may find descriptions of individual features that do not apply to your specific appliance INSTALLATION The manufacturer will not be held liable for any damages resulting from in correct or improper installation The minimum safety distance between the cooker top and the extractor hood is 650 mm some models can be installed at a lower height please re fer to the paragraphs on working dimensions and installation Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood For Class appliances check that the domestic power supply guarantees adequate earthing Connect the extractor to the exhaust flue through a pipe of minimum diame ter 120 mm The route of the flue must be as short as possible Do not connect the extractor hood to exhaust ducts carrying combustion fumes boilers fireplaces etc If the extractor is used in conjunction with non electrical appliances e g gas burning appliances a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust
2. RANGEmaster Clarence Street Royal Leamington Spa Warwickshire CV31 2AD England Tel 44 0 1926 457400 Fax 44 0 1926 450526 E mail consumers rangemaster co uk www rangemaster co uk AGA RANGEMASTER GROUP PLC 4329645
3. fixing 650 min Wall marking Draw a vertical line on the supporting wall up to the ceiling or as high as practical at the centre of the area in which the hood will be installed Draw a horizontal line at 650 mm above the hob for installation without the back panel or at height H height of the visible part of the panel for installation with the back panel Place bracket 7 2 1 on the wall as shown about 1 2 mm from the ceiling or upper limit aligning the centre notch with the vertical reference line Mark the wall at the centres of the holes in the bracket Place bracket 7 2 1 on the wall as shown at X mm below the first bracket X height of the upper chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres of the holes in the bracket Place bracket 7 1 as shown 120 mm from the vertical reference line and 175 mm above the horizontal reference line Mark the centres of the holes in the bracket Repeat this operation on the other side REAR PANEL OPTIONAL The Rear Panel must be fitted before fixing the hood body and if it is to be fixed at both top and bottom must be fitted at the correct height prior to installing the bases As this operation is rather complex it should be carried out either by the kitchen installer or a qualified person who knows the final dimensions of the units For fixing at the top only proceed as follows Rest the ba
4. gas The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air USE The extractor hood has been designed exclusively for domestic use to elimi nate kitchen smells Never use the hood for purposes other than for which it has been designed Never leave high naked flames under the hood when it is in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it does not engulf the sides Deep fat fryers must be continuously monitored during use overheated oil can burst into flames Do not flamb under the range hood risk of fire This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concern ing use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appli ance MAINTENANCE Switch off or unplug the appliance from the mains supply before carrying out any maintenance work Clean and or replace the Filters after the specified time period Fire hazard Clean the hood using a damp cloth and a neutral liquid detergent The symbol X on the product or on its packaging indicates that this product may not be treated as household waste Instead it shall be handed over to the applicable c
5. the grease filters see paragraph Maintenance being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan Chimney assembly Upper chimney section Lower exhaust flue Slightly widen the two sides of the upper chimney and hook them behind the brackets 7 2 1 making sure that they are prop erly housed Secure the sides to the brackets using the 4 screws 12e 2 9 x 9 5 supplied Insert the lower flue fixing bush 17 in the top of the hood body and rotate it 90 clockwise as far as it will go Slightly widen the two sides of the chimney and hook them between the upper chimney section and the wall making sure that they are properly housed Secure the sides of the bottom section to the bushes provided using the 2 screws 12c 2 9 x 9 5 supplied On the recirculation version fit the directional grids 8a 8b in their housings making sure that the directional symbols are to wards the top and front of the hood Also make sure that they are correctly inserted in the outlet connection piece 15 USE L Light Switches the lighting system on and off M Motor Switches the extractor motor on and off V Speed Sets the operating speed of the extractor 1 Low speed used for a continuous and silent air change in the presence of light cooking vapour 2 Medium speed suitable for most operating conditions given the optimum treated air flow noise level r
6. atio 3 Maximum speed used for eliminating the highest cooking vapour emis sion including long periods MAINTENANCE Grease filters CLEANING METAL SELF SUPPORTING GREASE FILTERS The filters must be cleaned every 2 months of operation or more frequently for particularly heavy usage and can be washed in a dishwasher e Remove the filters one at a time by pushing them towards the back of the group and pulling down at the same time Wash the filters taking care not to bend them Allow them to dry before refitting When refitting the filters make sure that the handle is visible on the outside Activated charcoal filter Recirculation version These filters are not washable and cannot be regenerated and must be replaced approximately every 4 months of operation or more frequently with heavy usage REPLACING THE ACTIVATED CHARCOAL FILTER Remove the metal grease filters e Remove the saturated activated charcoal filter as shown A e Fit the new filters B Replace the metal grease filters Lighting LIGHT REPLACEMENT 40 W incandescent light Remove the metal terminals fixing the light cover e Slide the light cover to the right until the left hand is free Lower it slightly and slide it to the left to free it completely Unscrew the bulbs and replace them with new ones having the same characteristics Replace the lighting support in reverse order
7. ck panel on the base inserting the lower plate between the upper surface and the wall centring it on the vertical reference line Mark the centres of the two holes in the upper plate Drill 8 mm holes at all the centre points marked Insert the wall plugs 11 in the holes Fix the brackets using the 12a screws supplied Fix the back panel where present using the 12a screws supplied Mounting the hood body e Screw the two screws 12d supplied onto the brackets 7 1 Hook the hood body onto the bracket 7 1 centring it around the vertical line Use the adjusting screws 12d underneath the hood to level the hood body Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version connect the hood to the chimney using either a flexible or rigid pipe 150 or 125 mm the choice of which is left to the installer To install a y 125 mm air exhaust connection insert re ducer flange 9 on the hood body air outlet and the adapting ring 6120 125 10 on the reducer flange Fix the pipe in position using sufficient pipe clamps not sup plied Remove any activated charcoal filters RECIRCULATION VERSION AIR OUTLET Push fit the air outlet fitting 15 onto the air outlet of the hood body e Ensure that the activated charcoal filters have been inserted ELECTRICAL CONNECTION Connect the hood to the mains through a two pole switch hav ing a contact gap of at least 3 mm Remove
8. ollection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product For more detailed information about recycling of this product please contact your local city office your household waste disposal service or the shop where you purchased the product 650 mm min CHARACTERISTICS Dimensions max 760 min 560 55 90 e e 698 898 492 190 S 010 g E 2 r 58 Components Ref Q ty Product Components 1 1 Hood Body complete with Controls Light Blower Filters EL 2 Telescopic Chimney comprising 2 1 UpperSection 2 2 1 Lower Section 8a 1 Right Air Outlet Grill 8b 1 LeftAir Outlet Grill 9 1 Reducer Flange 150 120 mm 10 1 Adapting ring 120 125 mm 15 1 Air Outlet Connection 17 2 _ Lower Chimney Fixing Bush Ref Q ty Installation Components 7 1 2 Hood Body Fixing Brackets 7 231 2 Upper Chimney Section Fixing Brackets 11 8 Wall Plugs 12a 8 Screws 4 2 x 44 4 12c 6 Screws 2 9 x 9 5 12d 2 Screws M4 x 25 Q ty Documentation 1 Instruction Manual INSTALLATION Wall drilling and bracket

Download Pdf Manuals

image

Related Search

Related Contents

Samsung SGH-U300 Lietotāja rokasgrāmata  Yocto Reference Manual  manuale tecnico 2013 - Accomandita Tecnologie Speciali Energia  Spinal-Stim® Quick Instructions - Bone Growth Stimulation for  Wiley Adobe Creative Suite 4 Bible  Stratos®Pro A2... PH 取扱説明書  MANUAL DE USUARIO  REVISION HISTORY BG3R  Autómatas Premium TSX P57/ TSX DEY / DSY  