1. rain or snow does not fall directly on to it e Never install the sensor on metal bases and objects or do not place it inside metal covers e If possible locate the sensor on the north side of the house so that temperature measurement is not distorted by the effect of sunlight e For proper measurement it is necessary for air to flow around the sensor Temperature measurement function 1 Indoor temperature display range 0 C to 50 C 2 Expected operating indoor temperature measurement range 0 C to 40 C 3 Outdoor temperature display range 20 C to 70 C 4 Expected operating outdoor temperature measurement range 5 C to 45 C Indoor temperature measurement accuracy 1 5 C Outdoor temperature measurement accuracy 1 5 C Sampling period 12 seconds Temperature sampling is disabled when the alarm is beeping Number of remote units Max 3 units Radio frequency 433 MHz Range up to 30 m in open space 10 Power source main unit 2 x 1 5 V type AA batteries sensor 2 x 1 5 V type AAA batteries 11 Dimensions main unit 75 x 68 x 173 mm weight 153 g sensor 95 x 60 x 25 mm weight 60 g Model colours SWS 21 S silver with a pink combination on the sides SWS 21 BU blue sides a COND Fast CR a s declares that SWS 21 S BU C SWS 21 TS conform to the basic requirements and other relevant provisions of the directive 1999 5 ES The device can be operated in the EU without restrictio
2. CH key once the setting will go forward one step hold the key for 2 seconds it will run forward by 8 steps second Press DOWN CF key one time the setting will go backward for one step hold the key for 2 seconds it will run back by 8 steps second The system will exit automatically if no key is pressed within 15 seconds And the previous setting will be confirmed automatically Setting the alarm 4 Hold the SET key for 2 seconds to enter into alarm settings The settings item will flash 1 HZ The alarm setting sequence Hour gt Minute gt exit Press the UP key once the setting will move forward by one step hold the key for 2 seconds it will move forward by 8 steps second Press the DOWN CF once the setting will go backward by one step hold the key for 2 seconds it will move back by 8 steps second EN 4 Press the ALM key to confirm the setting The system will exit automatically if no key is pressed within 15 seconds And the previous setting will be confirmed automatically 8 Press the ALARM key to switch the alarm on off sequence AL1 ON AL2 OFF gt AL2 ON AL1 OFF gt AL1 AL2 gt AL1 AL2 OFF 9 The alarm will beep for 2 seconds as below a 0 10 sec one BEEP per second b 10 20 sec two BEEPS per second c 20 30 sec four BEEPS per second d after 30 sec BEEP continuously e When the alarm is beeping pre
3. SENCOR SENCOR Tat ATHY aaa ot SWS 21 USER S MANUAL NAVOD K OBSLUZE NAVOD NA OBSLUHU FELHASZNALOI KEZIKONYV INSTRUKCJA OBS UGI EN cz SK HU PL Wireless Thermometer Bezdratovy teplom r Bezdr tov teplomer Dr tn lk li h m r Termometr bezprzewodowy Operation Instruction I Main Functions 1 Six function keys SET ALARM LCD UP CH DOWN CF SNOOZE 2 Time can be set to 12 of 24 hour format 3 Temperature can be set in degrees C or F 4 Indoor temperature range 0 C to 50 C 5 Outdoor temperature range 20 C to 60 C 6 Outdoor temperature using a radio signal up to 3 channels 7 Double alarm function 8 Snooze function rings again after 5 minutes 9 DST function Daylight Saving Time Il Key Function Function SET Up CH DOWN CF SNOOZE ALARM LCD Operation a Press Switch Switch RF C F Backlight On off g display channel switchable on alarm 2 a enter into Enter 2 Hold timefalarm PYRE Jo a o into LCD a data Brightness S setting setting 5 ae one step one step a Press ati forward pack Soe e ate 3 etting d enter into 8steps 8steps 7 Hold time second second fe e fee setting forward back Pi Confirm one step One step 2 iai the Setting forward back a e 3 enter into 8steps 8steps Hold alarm s
4. econd second wees o oo setting forward back III Instruction of Operating 3 1 Reception of the DCF signal 1 Press and hold the DOWN button for 2 seconds to receive the DCF signal manually The RC symbol will flash on the display If the reception is successful the RC symbol is shown on display 2 DST is shown on display if it is in Daylight Saving Time mode Note The clock automatically scans the time signal at AM2 00 AM3 00 AM4 00 and AM5 00 EN 3 3 2 Normal modes 3 3 3 4 uF 2 3 4 Press the SET key to set the alarm mode Hold SET key to enter the settings mode Press UP CH key to switch the radio channel sequence CH1 gt CH2 gt CH3 Hold UP CH key to clear all the data of the current channel Press the DOWN CF key to switch between C F Hold LCD key for 2 seconds to adjust the LCD brightness setting total of 8 levels Press the ALM key to switch the alarm on off When the alarm is ringing click the SNOOZE key once to enter into snooze mode the alarm will ring again after 5 minutes Setting the time 1 2 3 The time setting sequence 12 24HR gt OFF SET gt ask Hold the SET key for 2 seconds to enter into time settings The settings item will flash 1 HZ Hour gt Minute gt Language gt Year gt Month gt Date gt Exit Press the SET key to confirm the setting Press the UP
5. n The declaration of conformity is a part of the user s manual or can be found at the website www sencor eu EN 6 INSTRUCTIONS AND INFORMATION REGARDING THE DISPOSAL OF USED PACKAGING MATERIALS Dispose of packaging material at a public waste disposal site DISPOSAL OF USED ELECTRICAL AND ELECTRONIC APPLIANCES The meaning of the symbol on the product its accessory or packaging indicates that this product shall not be treated as household waste Please dispose of this product at your applicable collection point for the sal recycling of electrical amp electronic equipment waste Alternatively in some states of the European Union or other European states you may return your products to your local retailer when buying an equivalent new product The correct disposal of this product will help save valuable natural resources and help in preventing the potential negative impact on the environment and human health which could be caused as a result of improper liquidation of waste Please ask your local authorities or the nearest waste collection centre for further details The improper disposal of this type of waste may fall subject to national regulations for fines For business entities in the European Union If you wish to dispose of an electrical or electronic device request the necessary information from your seller or supplier Disposal in other countries outside the European Union If you wish to dispose of this product
6. request the necessary information about the correct disposal method from local government departments or from your seller Changes to the text design and technical specifications may occur without prior notice and we reserve the right to make these changes EN 7
7. ss the SNOOZE key once to enter the snooze mode the alarm will beep again after 5 minutes press another key to exit No IV Power On and reset When you turn on the power and perform a reset the LCD will display all the indicators for 3 seconds 2 enter the normal mode is set after the Beep 2 the temperature is checked 2 the reception of the radio signal from the sensor is activated for 3 minutes V Receiving a radio signal from the outdoor sensor 5 1 Function for receiving a signal 1 After installing the battery and checking temperature it will enter radio signal reception mode automatically for 3 minutes 2 In the normal display mode hold the UP CH key for 2 seconds to delete the channel information and to re register channel 3 If there is no effective signal with same ID code received for the current channel within 1 hour the temperature of that CH will show and it will wait to re register a channel At the same time the radio signal reception is activated for 3 minutes if no valid signal appears within 3 minutes the reception of the radio signal will turn off The radio reception will be activated for 3 minutes in next hour and this will be repeated until a radio signal is received or until you hold the UP CH key EN 5 Installation location of the sensor e The cover of the external sensor is not waterproof If the sensor is located outdoors it must be located in such a location that