1. 3 a flr ed Nominal iohingpower w foo Ww Average illumination of the lighting EMidale 369 0 Lux eee ee Ee E standby ee mode Lamp efficiency CDA To contact our Customer Care Department or for Service please contact us on the details below
2. EVPC9 Extractor Manual for Installation Use and Maintenance C DA Important The manufacturer cannot be held responsible for injuries orlosses caused by incorrect use Please note that the manufacturer reserves the right to invalidate the guarantee supplie incorrect installation or misuse of the appliance or use in a commercial environment This appliance is not designed to be used by people including children with reduced capacity or who lack experience or knowledge about it unless they have had supervision the appliance by someone who is responsible for their safety Undernocircumstancesshouldany external covers beremovedforservicingormaintenan personnel Appliance information Please enter the details on the appliance rating plate below for reference to assist CDA Ci fault with your appliance and to register your appliance for guarantee purposes CE Declarations of Conformity Thisappliancehasbeenmanufacturedtothestricteststandardsandcomplieswithallapplic safety Electrical safety LVD and Electromagnetic interference compatibility EMC IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN DIRECTIVE 2002 96 EC At the end of its working life the product must be taken to a special local authority wi dealer providing appliance recycling services Disposing of a household appliance separa consequences for the environment and health It also enables the constituent materials energy and res
3. ed distance between the hob and extractor must be greater than 650mm then that is the distance that should be observed thisisalegal requirementand mayleadtoyourhob being disconnected from the gas supply and the installation being reported to RIDDOR The height should be measured from the top of the burners IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED WITH THE GAS HOB THE MINIMUM DISTANCE l BETWEEN THE HOB AND EXTRACTOR MUST BE AT l l l LEAST 760mm 650mmrecommended The width of any hob must not be greater than the width of the extractor installed above it Fig 5 re T A Ducting and Ventilation For best performance and lowest noise output we recommend the use of 125mm or 150mm ducting You can also use 100mm ducting but this will reduce performance Installation It is important that wall plugs and screws are selected that are suitable for the wall type you will be fixing the extractor to CDA will not be liable for any issue arising from the use of unsuitable plugs and screws The extractor is mounted to the wall using brackets and support rails To install the product onto the wall proceed as follows 1 Position the template D on the wall and mark the positions of the drill holes on the wall Note that the bottom edge of the template should be the height required above the hob Fig 6 2A 2 Drill holes suitable for the wall plugs you are using and fix the support rails E and brackets C to the wall usin
4. g suitable screws F Fig 6 2B 3 With the help of another individual lift the appliance and slot it into the support rails A as shown Fig 7 4 Secure the extractor to the top brackets C using the supplied screws E The extractor is now secured to the wall Fig 8 Installation 5 Using the chimney top support bracket as a guide mark the hole positions on the wall and ceiling at the required positions Fig 9 5A amp B drill and fit the bracket to the wall and ceiling using appropriate fixings D amp E 6 If venting the extractor outside connect the vent adaptor to the ducting pipe as shown if Fig 10 If using the extractor as a re circulation device assemble the vent diverter and connect the ducting and vent adaptor as shown in Fig 11 7 Fit the chimney sections Y and secure to the chimney support bracket C using the two provided screws X as shown in Fig 8 8 Drill and insert 2 plugs suitable for use with the wall type into the holes and fix the bracket with 2 screws 9 Fit the chimney section and secure to the mounting bracket with the supplied screws fig 12 Energy Efficiency Information Atribute Symbol Model Identification es C Annual E Consumption 119 6 Ee CC Energy Efficiency Index aa Measured airflow at Best Efficiency Qgep 347 6 m h Point Measured Pressure at Best Efficiency 244 0 aa ie Measured electric power at Best Weep 146
5. mise the risk of fire When the display flashes alternating the speed selected with the letter A or at least once a month you should remove and clean the grease filters with hot soapy water You can also wash the grease filters in a dishwasher ensuring that you place it in an upright position to prevent damage from other items in the dishwasher After rinsing and drying replace the filters After the grease filters has been replaced the electronic memory must be reset by touching key A for approximately five seconds until the letter A stops flashing To remove the grease filters follow the steps below 1 Pull open the handle on the grease filter as shown in fig 2 It will release at the handle side 2 Then lower the grease filter to remove it completely To replace the grease filters repeat the steps in reverse Please note Cleaning the grease filter in the dishwasher may lead to discolouration This is normal and does not constitute a fault with the appliance Changing the charcoal filter re circulating only When the display flashes alternating the speed selected with the letter F the charcoal filters must be replaced After the charcoal filter has been replaced the electronic memory must be reset by touching key A for approximately five seconds until the letter F stops flashing To attach a new charcoal filter first remove the grease filters as described above Then offer up the charcoal filter to body of the extracto
6. ources As a reminder of the need to dispose of household appliances sepa with a crossed out wheeled dustbin sy Please note Under no circumstances should the extractor be connected to any gas ventilation s ducting system Donot vent the extractor into an attic or loft space Only house the extractor in rooms with adequate ventilation Remember that the e whatever air is extracted needs to be replaced Do not tile the extractor in It should be removable for service or maintenance Donot use silicone sealant to secure the hood to the wall You must be able to isolate the extractor from the mains electrical supply after insta Steam cleaners must not be used when cleaning this appliance The performance of your extractor will vary depending on a number of factors Thes length of ducting room volume ventilation available and cleanliness of the filters Using your Extractor For best performance you should switch on the extractor 15 minutes before starting to approximately 15 minutes after the end of cooking Control Panel A Light key B Decrease speed key C Display D Increase speed key E Timer key To switch the extractor light on and off Touch key A To switch on the extractor Touch either key B or D The appliance will switch on at the first speed To increase the speed touch key D To switch the extractor off touch and hold key B for two seconds when the e
7. r as shown in figure 3 Repeat with the other charcoal filter Then replace the grease filters Changing the Light DO NOT CHANGE THE LIGHT BULB IMMEDIATELY AFTER USE AS THE BULB WILL BE HOT ALLOW IT TO COOL BEFORE REMOVING IT Unscrew the light bulb cover please see figure 4 Unscrew the light bulb and replace with a 12V 20W halogen light bulb Finally replace the light bulb cover Do not touch bulbs or adjacent areas during or straight after prolonged use of the lights The light is designed for use during cooking and not for general room illumination Extended use of the light can reduce the life span of the bulb Bulb replacement is not covered by the guarantee Only use bulbs recommended for your extractor Do not fit bulbs of a higher power rating Bulbs of a lower power rating may be adequate for use generally last longer and use less energy Mains Electricity Connection THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY BY A COMPETE WIRING VIA A DOUBLE POLE SWITCHED FUSED SPUR OUTLET AND PROTECTED BY A 3A Werecommend thatthe appliance is connected bya qualified electrician whoisamember comply with the I E E and local regulations The wires in the mains lead of this appliance are coloured in accordance with the Pie pee OUEN following code BLUE NEUTRAL BROWN LIVE As the colours of the wires in the mains lead for the appliance may not correspond withthe coloured markings identifying
8. the terminals connecting tothe fused spur proceed as follows The wire which is coloured blue must be connected to the terminal marked N Neutral or coloured black USE A 3 AMP FUSE The wire which is coloured brown must be connected to the terminal marked L Live or coloured red NOTE USE A 3A FUSE Assembly and electrical connection should be carried out by competent personnel When installing this product we recommend you seek the help of another individual IMPORTANT THIS APPLIANCE IS A CLASS Il APPLIANCE DOUBLE INSULATED A BE EARTHED DO NOT FIT AN EARTH LEAD TO THIS EXTRACTOR Do not mount the isolation switch behind the chimney section It is a requirement that yo extractor from the mains electrical supply after installation This appliance is intended to be connected to the mains electrical supply by means of an is and is intended to be protected by a 3A fuse The use of a 13A fuse can cause damage to thi of a fault and may also invalidate the warranty Electrical Information Mains electrical voltage 230 240Vac 50Hz Total rated power consumption 310W Troubleshooting If your extractor is not working 1 Check that the mains supply has not been switched off 2 Check that the fuse in the spur has not blown Mounting your Extractor When theextractoristobe installed abovehob theminimum distancebetweenthehobandextractormustexceed650mm If the instructions provided with your gas hob state that the requir
9. xtractor i touch key B at speed one The intensive function The extractor is equipped with an intensive function which runs for ten minutes befi selected speed To activate the intensive function touch key D at speed three The d intensive function is on The timer The extractor is equipped with a timer that allows the extractor to run for 15 minute automatically To activate the timer touch key E The display will flash a decimal point when the ti Please note The timer cannot be activated when the intensive function is on The clean air function The extractor is equipped with a clean air function that switches on the motor for te speed one To activate the clean air function touch key E for two seconds when the appliance is function touch either key B or D To switch off the clean air function touch key E TI in sections whilst the motor is running and will show the letter C during the fifty mi not running Care and Maintenance IMPORTANT DO NOT PERFORM MAINTENANCE OR CLEANING OF THE EXTRACTOR WITHOUT FIRST SWITCHING OFF THE ELECTRICITY SUPPLY Cleaning You should use a nonabrasive cleaner Any abrasive cleaner including Cif will scratch the surface and could erase the control panel markings You can clean your extractor effectively by simply using a dilute solution of water and mild detergent and drying to a shine with a clean cloth Cleaning the grease filter The grease filters should be kept clean to mini
Download Pdf Manuals
Related Search
Related Contents
and increase your customers` sales DRAGER Oxylog 2000+ Ventilator Service Manual ELI 100 Service Manual - Frank`s Hospital Workshop guide_iColorCoveMX_PC(g2). 69-2718ES-01 - Honeywell Wi-Fi Programmable Thermostats Wireless Temp and/or Humidity System Instructions DJUPFRYSA User Manual SOM-5790 Sistema de telemando para el accionamiento/parada remoto de un XBee SE Manual Copyright © All rights reserved.