Home
Kidde KN-COPP-B-LP
Contents
1. a D SIGNALING LISTED Carbon Monoxide Alarm User s Guide Models KN COB B LP and KN COPP B LP with Digital Display KN COB B LP Kidde i i l KN COPP B LP with Digital Display F Kidde e Digital Display e Peak Level Memory e 3 AA Battery Operation Ne A ATTENTION Please take a few minutes to thoroughly read this user s guide which should be saved for future reference and passed on to any subsequent owner Manual P N 21008088 Rev B 10 12 2531 7201 00 What to do When the Alarm Sounds Carbon Monoxide Alarm Procedure WARNING Activation of the CO Alarm indicates the presence of Carbon Monoxide CO which can kill you Operate the Test Reset button Call your emergency services Fire Department or 911 PHONE NUMBER Immediately move to fresh air outdoors or by an open door window Do a head count to check that all persons are accounted for Do not reenter the premises nor move away from the open door window until the emergency services responders have arrived the premises have been aired out and your alarm remains in its normal condition After following steps 1 3 if the alarm reactivates within a 24 hour period repeat steps 1 3 and call a qualified appliance technician to investigate sources of CO from fuel burning equipment and appliances and to inspect for proper operati of equipment PHONE NUMBER If problems are identified during this inspection
2. The number on the display will turn to 0 the memory will be cleared and the alarm will begin monitoring for CO The Peak Level memory is also reset when the unit loses power 7 Alarm Characteristics Carbon Monoxide Alarm Indicator When the alarm senses a dangerous level of CO the unit will emit a loud alarm pattern The alarm pattern is 4 quick beeps followed by 5 seconds of silence repeating for as long as dangerous conditions exist The red Alarm LED will flash the same pattern and the digital display where equipped will indicate CO concentrations in parts per million PPM NOTE This unit is sealed The cover is not removable Due to the loudness of the alarm we suggest that you place your fingers over the sounder opening while testing your alarm Caution Continuous exposure to the high sound level of this alarm over an extended period of time may cause hearing loss Testing To test the alarm press the Test Reset button If the unit is operating properly you will hear 4 quick beeps followed by 5 seconds of silence followed by 4 quick beeps For model KN COPP B LP with digital display The display will show three and then show 888 The red LED will flash along with the beeps Within several seconds the unit will return to monitor for CO Note You do not need to press the Test button to take a CO reading Maintenance Tips To keep your alarm in good working order you must follow these
3. To help identify the date to replace the alarm a label has been affixed to the side of the alarm Write the replace by date ten years from power up in a permanent marker on this label 2 Product Features and Specifications Temperature Operating Range 40 F 4 4 C to 100 F 37 8 C Humidity Operating range 10 95 non condensing Audible Alarm 85 dB at 10 3 4 0 5 KHz pulsing alarm Sensor Electrochemical Power 3 AA Batteries Accuracy of Digital Display Model KN COPP B Only 30 999 PPM 30 when measured in conditions of 80 F 10 F atmospheric pressure 10 and 40 3 relative humidity Display readings may vary slightly depending on changes in the ambient condition temperature humidity and the condition of the sensor Alarm Response Times 70 PPM 60 240 min 150 PPM 10 50 min 400 PPM 4 15 min 3 Installation Locations Recommended Installation Locations CO alarms should be mounted in or near bedrooms and living areas It is recommended that you install a Kidde CO alarm on each level of your home BEDROOM When choosing your installation locations make sure you can hear Recommended Locations the alarm from all sleeping areas If you install only one CO alarm in your home install it near bedrooms not in the basement or furnace room e When wall mounting place out of reach of children Under no circumstances should children be allowed to handle the CO
4. monoxide at the sensor Carbon monoxide may be present in other areas Important Warning Statements A WARNING This product is intended for use in ordi nary indoor locations of family living units It is not designed to measure compliance with Occupational Safety and Health Administration OSHA commercial or industrial standards It is not suitable for installation in hazardous locations as defined in the National Electric Code The installation of this device should not be used as a substitute for proper installation use and maintenance of fuel burning appliances including appropriate ventilation and exhaust sys tems It does not prevent CO from occurring nor can it solve an existing CO problem WARNING This device is designed to protect individuals from acute effects of carbon monoxide exposure It may not fully safeguard individuals with specific medical conditions If in doubt consult a medical practitioner Individuals with medical problems may consider using warning devices which provide audible and visual signals for carbon mon oxide concentrations under 30 PPM This carbon monoxide alarm requires a continuous supply of elec trical power it will not work without power This alarm has not been independently investigated for carbon monoxide detection below 70 PPM Contents of This User s Guide 1 Information About Carbon Monoxide Product Features and Specifications Installation Locations Installation I
5. alarm Placing the alarm at eye level allows for optimum monitoring of the digital display 3 Installation Locations Locations To Avoid IMPORTANT Improper location can affect the sensitive electronic com ponents in this alarm To avoid causing damage to the unit to provide op Do no Do no 4 4 C porches and garages Do no recom Do no ventila Do no Do no Do no Do no ins he sensor ins or ins men ins tion ins ins ins imum performance and to prevent unnecessary nuisance alarms all in kitchens garages or furnace rooms that may expose to substances that could damage or contaminate it all in areas where the temperature is colder than 40 F hotter than 100 F 37 8 C such as crawl spaces attics all within 5 ft of heating or cooking appliances Kidde ds 15 ft to prevent nuisance alarms all near vents flues chimneys or any forced unforced air openings all near ceiling fans doors windows or areas directly exposed to the weather all in dead air spaces such as peaks of vaulted ceilings or gabled roofs where CO may not reach the sensor in time to provide early warning all this unit near deep cell large batteries Large batteries have emissions that can cause the alarm to perform at less than optimum performance obstruct the vents located on the alarm Do not place the alarm where drapes furniture or other objects block the flo
6. e Excessive spillage or reverse venting of fuel burning appliances caused by outdoor ambient conditions such as wind direction and or veloc ity including high gusts of wind heavy air in the vent pipes cold humid air with extended periods between cycles e Negative pressure resulting from the use of exhaust fans e Simultaneous operation of several fuel burning appliances competing for limited internal air e Vent pipe connections vibrating loose from clothes dryers furnaces or water heaters e Obstructions in or unconventional vent pipe designs which can amplify the above situations e Extended operation of unvented fuel burning devices range oven fireplace etc e Temperature inversions which can trap exhaust gases near the ground e Vehicle idling in an open or closed garage or near a home To be safe know the possible sources of CO in your home Keep fuel burning appliances and their chimneys and vents in good working condition Learn the early symptoms of exposure and if you suspect CO poisoning move outside to fresh air and get emergency help Your first line of defense is an annual inspection and regular maintenance of your appliances Contact a licensed contractor or call your local utility com pany for assistance Information About Carbon Monoxide Alarms What They Can and Cannot Do CO alarms provide early warning of the presence of CO usually before a healthy adult would experience symptoms T
7. steps e Test the alarm once a week by pressing the Test Reset button e Vacuum the alarm cover once a month to remove accumulated dust e Never use detergents or solvents to clean the alarm Chemicals can permanently damage or temporarily contaminate the sensor e Avoid spraying air fresheners hair spray paint or other aerosols near the alarm e Do not paint the unit Paint will seal the vents and interfere with proper sensor operation Move the CO Alarm to a remote location to prevent possible damage or contamination of the sensor prior to performing any of the following e Staining or stripping floors or furniture painting or wall papering Aing aerosols or adhesives WARNING Reinstall the CO Alarm as soon as possible to assure continuous protection The following is a list of substances that at high levels can damage the sensor or cause temporary readings that are not CO readings e Ethylene ethanol alcohol iso propanol benzene toluene ethyl acetate hydrogen hydrogen sulfide and sulfur dioxide e Also most aerosol sprays alcohol based products paint thinner solvent adhesive hair spray after shave perfume auto exhaust cold start and some cleaning agents FCC COMPLIANCE STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference
8. 30 seconds 30 seconds respond to to CO 6 Model KN COPP B LP with digital display Operating Characteristics When the unit is first powered up the green Operate LED flashes once every 30 seconds and the digital display will show three eights indicating the alarm is in the start up mode The three eights will remain for approximately 30 seconds Then the alarm will display 0 and begin monitoring the air for CO and will continue to do so as long as it receives power This alarm will display a 0 if CO concentrations between 0 and 30 PPM have been detected within the last 15 seconds 6 Model KN COPP B LP with digital display Operating Characteristics The following table illustrates the possible digital displays describes the audible alarm patterns and the recommended actions to take Operating and Alarm Characteristics LCD Display Shows Alarm Sound Unit Status Recommendation 15 A steady display of 4 quick beeps Alarm condition Refer to What to X 2 CO concentration 5 secs silence Dangerous do When the Alarm from 30 999 Red repeating concentrations of Sounds inside front LED flashes with beep CO detected cover mc Brief 888 for None Self test when first None CO has 2211 approximately 30 powered up not been detected seconds Numbers shown for test purpose only Thre
9. Service Department 1016 Corporate Park Drive Mebane NC 27302 USA together with proof of purchase date Please include a note describ ing the problem when you return the unit The replacement product will be in warranty for the remainder of the original warranty period or for six months whichever is longer Other than the cost of postage no charge will be made for replacement of the defective product In many cases the quickest way to exchange your alarm is to return it to the original place of purchase If you have questions call Kidde customer service department IMPORTANT Do not remove unit back cover Back cover removal will void warranty Your Kidde Carbon Monoxide Alarm is not a substitute for property disability life or other insurance of any kind Appropriate insurance coverage is your responsibility Consult your insurance agent Also Kidde makes no warranty express or implied written or oral including that of merchant ability or fitness for any particular purpose with respect to the battery The above warranty may not be altered except in writing signed by both parties hereto QUESTIONS OR FOR MORE INFORMATION Call our Product Support line at 1 800 880 6788 or contact us at our website at www kidde com Kidde Kidde 1016 Corporate Park Drive Mebane NC 27302
10. e and 4 quick beeps Test Reset button is None CO has then 888 5 seconds pressed not been detected silence Numbers shown for repeated once test purpose only r Steady 0 displayed None Normal DC None L dot flashing every 5 operation with seconds Green LED good batteries lashes every 30 secs sensing no CO mL Lb flashes alter One quick beep Batteries need to Replace all three AA LO nately with any every 60 seconds be replaced batteries immediately number Red LED lashes every 60 seconds c_ _ Err displayed One quick beep Unit is_in error Replace bante It Ep evr every 30 seconds condition malfunctioned and must e replaced immediately Unit will not respond to CO Press the Peak Level P utton while unit is in Display is blank Constant alarm Unit malfunction Err mode to obtain error code and call Product Support line ws cy Number from None Peak Level Memory Refer to following t U4 11 999 displayed activated Highest section for informa concentration of tion regarding Peak CO detected is Level Memory displayed cs End displayed Two quick End of unit life Replace unit imme 92 Red LED flashes beeps every diately Unit will not two times 30 seconds respond to CO every 30 seconds The problems listed above are under normal operating conditions Other Err conditions could exist If you should have any questions regarding display conditions call our Produc
11. e either wall mounted or placed on a tabletop For wall mounting follow these steps 1 Remove back mounting plate from the alarm place it in the desired location 1 8 and mark the location of the two holes needed on the wall Screw Head Distance 2 Insert the two screws provided until the from Wall screw heads are protruding approximately 1 8 from the wall If mounting in a plasterboard or drywall drill a 3 16 hole in the wall and use the plastic anchors provided 3 Hook the CO alarm over the screws and onto the keyholes in the back mounting plate of the alarm After the mounting plate is secured to the wall slide the alarm down over the mounting Wall Mount plate until it snaps into place Your CO alarm may also be placed on a tabletop If the alarm is not wall mounted be sure it is no more than three feet from the floor The alarm does not have to be within three feet from the floor to detect CO but at this height it is less likely to sustain damage from a fall Important Labels Provided Two labels have been provided that have important information on what to do in case of an alarm Add the phone number of your emergency service provider in the space provided Place one label next to the alarm after it is mounted and one label near a fresh air source such as a door or window 5 Model KN COB B LP Operating Characteristics Whenever the alarm is operating the green Power LED fla
12. have the equip ment serviced immediately Note any combustion equipment not inspected by the technician and consult the manufacturer s instruc tions or contact the manufacturer s directly for more information about CO safety and the equipment Make sure that motor vehicles are not or have not been operating in a garage attached or adja cent to the residence Never restart the source of a CO problem until it has been corrected Never ignore the sound of the alarm If the alarm is sounding pressing the test reset button will terminate the alarm If the CO condition that caused the alert in the first place continues the alarm will reactivate If the unit alarms again within six minutes it is sensing high levels of CO which can quickly become a dangerous situation Welcome Note Many times throughout this User s Guide we will refer to Carbon Monoxide as CO This Kidde carbon monoxide CO alarm is an important part of your family s home safety plan This alarm has been designed and tested to detect CO buildup in a residential environment Your alarm is for use specifically in the home As an owner of a CO alarm there are some basic facts you should know about for your protection Many people think that CO alarms operate like smoke alarms Like smoke alarms CO alarms monitor the air in your home and sound a loud alarm to warn you of trouble The way you respond to a CO alarm is quite different than a smoke alarm That
13. his early warning is possible however only if your CO alarm is located installed and maintained as described in this guide 1 Information ut Carbon Monoxide Because carbon monoxide is a cumulative poison long term exposures to low levels may cause symptoms as well as short term exposures to high levels This Kidde unit has a time weighted alarm the higher the level of CO present the sooner the alarm will be triggered This CO alarm can only warn you of the presence of CO It does not prevent CO from occurring nor can it solve an existing CO problem If your unit has alarmed and you ve provided ventilation by leaving your windows and doors open the CO buildup may have dissipated by the time help responds Although your problem may appear to be temporar ily solved it s crucial that the source of the CO is determined and that the appropriate repairs are made This CO alarm is designed to act as a monitor it is not designed for use as a short term testing device to perform a quick check for the presence of CO CO alarms have limitations Like any other electronic device CO alarms are not fool proof CO alarms have a limited operational life You must test your CO alarm weekly because it could fail to operate at any time If your CO alarm fails to test properly or if its self diagnostic test reveals a malfunction immediately have the unit replaced This alarm will not monitor CO levels while in an error condition CO alar
14. in a residential installation This equipment gener ates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inter ference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected cConsult the dealer or an experienced radio TV technician for help TEN YEAR LIMITED WARRANTY Warranty Coverage The manufacturer warrants to the original consumer purchaser that this product except battery will be free of defects in material and workmanship for a period of ten 10 years from date of purchase The manufacturer s liability hereunder is limited to replacement of the product repair of the product or replacement of the product with repaired product at the discretion of the manufacturer This warranty is void if the product has been damaged by accident unreasonable use neglect tampering or other causes not arising from defects in material or workman
15. ms can only sense CO that reaches the unit s sensor It s possible that CO may be present in other areas without reaching the alarm The rate and ability that which CO reaches the alarm may be affected by e Doors or other obstructions e Fresh air from a vent an open window or other source e CO being present on one level of the home and not reach a CO alarm installed on a different level For example CO in the basement may not reach an alarm on the second level near the bedrooms For these reasons we recommend you provide complete coverage by placing a CO alarm on every level of the home Please carefully read all information in sections 2 and 3 on properly installing this CO alarm CO alarms should not be used to detect the presence of natural gas methane propane butane or other combustible fuels Instruct children never to touch or otherwise interfere with the alarm Warn children of the dangers of CO poisoning 2 Product Features and Specifications Test Reset Green Button Power LED Red Alarm LED Model KN COB B LP Green Test Reset Power LED Button Red Alarm LED Peak Level Button Digital Display Model KN COPP B LP with digital display A WARNING After ten 10 years from initial power up this alarm will beep two times every 30 seconds to indicate that it is time to replace the alarm Replace the alarm immediately It will not detect CO in this condition
16. nstructions KN COB B LP Operating Characteristics KN COPP B LP with digital display Operating Characteristics Alarm Characteristics Maintenance Oo os Oo 9 EP Ww NS Limited Warranty 1 Information About Carbon Monoxide General Carbon Monoxide Information Carbon monoxide is a colorless odorless and tasteless poison gas that can be fatal when inhaled CO inhibits the blood s capacity to carry oxygen Periodically review this user s guide and discuss your CO alarm emer gency procedure with all the members of your family Never ignore a CO alarm A true alarm is an indication of potentially dangerous levels of CO CO alarms are designed to alert you to the presence of CO before an emergency before most people would experience symptoms of CO poisoning giving you time to resolve the problem calmly Determine if anyone in the household is experiencing symptoms of CO poisoning Many cases of reported CO poisoning indicate that while victims are aware they are not well they become so disoriented they are unable to save themselves by either exiting the building or calling for assistance Also young children and household pets may be the first affected You should take extra precautions to protect high risk persons from CO exposure because they may experience ill effects from CO at levels that would not ordinarily affect a healthy adult Symptoms of CO Poisoning The following common symptoms are related to CO poisoning and sh
17. ould be discussed with ALL members of the household Mild Exposure Slight headache nausea vomiting fatigue often described as flu like symptoms Medium Exposure Severe throbbing headache drowsiness confusion fast heart rate Extreme Exposure Unconsciousness convulsions cardio respiratory failure death If you experience even mild symptoms of CO poisoning consult your doctor immediately 1 Information About Carbon Monoxide Carbon Monoxide PPM Levels model KN COPP B LP with digital display only Model KN COPP B LP is equipped with a digital display that shows levels of CO displayed in PPM parts per million Learn the difference between dangerous high mid and low levels Dangerous Levels When someone is experiencing symptoms of CO poisoning and CO read ings are generally above 100 PPM Anytime someone is experiencing the symptoms of CO poisoning this should be treated as an emergency See What to do When the Alarm Sounds inside front cover High Levels Generally above 100 PPM with no one experiencing symptoms This should be treated as an urgent situation See What to do When the Alarm Sounds inside front cover Mid Levels Generally between 50 PPM to 100 PPM This should be cause for concern and should not be ignored or dismissed See What to do When the Alarm Sounds inside front cover Low Levels Generally below 50 PPM Kidde recommends you take action to elimina
18. s because a house fire and a CO problem are two distinctly different situations If your smoke alarm were to alarm you would quickly be able to judge the level of danger you were in with your senses You can see and smell the smoke feel the heat see and possibly hear the fire burning You can also readily see if your smoke alarm is alarming in a non emergency situation Because your sense of sight smell hearing and touch give you information you can almost instantly judge what action to take if you hear your smoke alarm CO is an invisible odorless tasteless and non irritating gas completely undetectable to your senses That s why it is important to your safety that you have a CO alarm Important Warning Statements IMPORTANT This carbon monoxide alarm is designed to detect carbon monoxide from ANY source of combustion It is NOT designed to detect smoke fire or any other gas Z N WARNING Carbon monoxide alarms are not smoke alarms This carbon monoxide alarm is not a substitute for installing and maintaining an appropriate number of smoke alarms in your home This carbon monoxide alarm will not sense smoke fire or any poisonous gas other than carbon monoxide even though carbon monoxide can be generated by fire For this reason you must install smoke alarms to provide early warning of fire and to pro tect you and your family from fire and its related hazards CAUTION This alarm will only indicate the presence of carbon
19. shes every 30 seconds to indicate the unit is monitoring for CO If the alarm senses dangerous levels of CO the red Alarm LED will flash and the alarm will emit an audible alarm pattern Operating and Alarm Characteristics Function LED Display Alarm Sound Unit Status Recommendation Normal Green LED None Normal DC lone Operation flashes every 30 operation sensing seconds no CO and with good batteries Carbon ed LED flashes 4 quick beeps Alarm condition efer to What to monoxide with beeps 5 seconds Dangerous con do When the Alarm alarm silence centrations of CO Sounds inside front repeating detected cover Low ed LED flashes One quick Batteries need to be Replace all three AA battery every 60 seconds beep every replaced batteries 60 seconds Error ed LED flashes One quick Unit is in error eplace battery service every 30 seconds beep every condition If condition continues alarm 30 seconds unit has malfunc tioned Replace Error ed LED Constant Very low battery or immediately Unit will constantly on alarm unit malfunction not respond to CO Normal ed LED flashes 4 quick beeps Normal operation CO not detected Test Reset with beeps 5 seconds when Test Reset Alarm for test pur function silence button is pressed poses only repeated once End of ed LED flashes Two quick End of unit life Replace unit imme unit life two times beeps every diately Unit will not indicator every
20. ship This warranty extends to the original consumer purchaser of the product only Warranty Disclaimers Any implied warranties arising out of this sale including but not lim ited to the implied warranties of description merchantability and fitness for a particular pur pose are limited in duration to the above warranty period In no event shall the Manufacturer be liable for loss of use of this product or for any indirect special incidental or consequential damages or costs or expenses incurred by the consumer or any other user of this product whether due to a breach of contract negligence strict liability in tort or otherwise The Manufacturer shall have no liability for any personal injury property damage or any special incidental contingent or consequential damage of any kind resulting from gas leakage fire or explosion Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you Some states do not allow the exclusion or limitation of consequential or incidental damages so the above limitations or exclusions may not apply to you Legal Remedies This warranty gives you specific legal rights and you may also have other tights that vary from state to state Warranty Performance During the above warranty period your product will be replaced with a comparable product if the defective product is returned in a postage paid package to the following address Kidde Customer
21. t Support line 6 Model KN COPP B LP with digital display Operating Characteristics Peak Level Memory model KN COPP B LP only When the Peak Level button is pressed and held the display shows the highest CO reading taken by the CO alarm since its last reset or power up In this example 120 PPM pe was the maximum amount of CO recorded since the ao Li unit was last reset Yam imlo The Peak Level display feature will display levels Sample Peak between 11 999 PPM Although the Peak Level Level Reading feature will display levels below 30 PPM these levels will not result in an alarm no matter how long the device is exposed to these levels The Peak Level feature is helpful in identifying if you have had a CO reading since resetting the alarm Concentrations of CO between 1 and 30 PPM can often occur in normal everyday conditions Concentrations of CO below 30 PPM may be an indication of a transient condition that may appear today and never reappear Some CO conditions may start out as low level leaks but could develop into CO concentrations that may become harmful If this happens the CO alarm will detect the dangerous level and alarm notifying you and others of the conditions DO NOT ignore high concentration readings above 30 PPM or a CO alarming device that is in alarm Peak Level Memory Reset Press the Peak Level button with the button still pressed press the Test Reset button for two seconds and release
22. te the source of CO See What to do When the Alarm Sounds inside front cover IMPORTANT Model KN COB B LP does not have a digital display and does not display carbon monoxide levels in PPM If the alarm sounds it should be treated as a potentially serious condition See What to do When the Alarm Sounds inside front cover Possible Sources of Carbon Monoxide Inside your home appliances used for heating and cooking are the most likely sources of CO Vehicles running in attached garages can also produce dangerous levels of CO CO can be produced when burning any fossil fuel such as gasoline pro pane natural gas oil and wood It can be produced by any fuel burning appliance that is malfunctioning improperly installed or not ventilated correctly such as e Automobiles furnaces gas ranges stoves gas clothes dryers water heaters portable fuel burning space heaters and generators fireplaces wood burning stoves and certain swimming pool heaters e Blocked chimneys or flues back drafts and changes in air pressure cor 1 Information About Carbon Monoxide roded or disconnected vent pipes loose or cracked furnace exchangers e Vehicles and other combustion engines running in an open or closed garage attached or near a home e Burning charcoal or fuel in grills and hibachis in an enclosed area Conditions That Can Produce Carbon Monoxide The following conditions can result in transient CO situations
23. w of air o the vents 4 Installation Instructions Battery Installation and Replacement To install or replace the batteries in this Kidde CO alarm please perform the following steps 1 Slide open the bottom cover to expose the battery compartment 2 If replacing batteries remove the old batteries and properly dispose of them as recommended by the battery manufacturer 3 Install the new batteries Note the polarity illustration in the battery compartment 4 Close the bottom cover Note The bot tom cover will not close if all three AA batteries are not installed When replacing the batteries use one of the following approved brands e Duracell MN1500 or MX1500 e Energizer E91 e Gold Peak 15A Battery Polarity e Golden Power GLR6A for the three AA batteries These batteries can be purchased where you bought the alarm or at a local hardware store Use of a different battery may have a detrimental effect on the alarm operation IMPORTANT Constant exposures to high or low humidity may reduce battery life A good safety measure is to replace the battery at least once a year or at the same time as you change your clocks for daylight saving time After installing or changing the batteries reinstall your alarm Test your alarm by using the Test Reset button and check that the green LED flashes once approximately every 30 seconds 4 Installation Instructions Mounting WALL This CO alarm can b