Home
        Aeon Labs Smart Energy Switch 3
         Contents
1.   The relationship between one device controlling another device is called  association  In order to control a different device  the controlling device needs to maintain a list of devices that will receive  controlling commands  These lists are called association groups and they are always related to certain events  e g  button  pressed  sensor triggers        In case the event happens all devices stored in the respective association group will receive a  common wireless command     Association Groups     1 Group 1  max  nodes in group  5     2 Group 2  max  nodes in group  5     Configuration Parameters     c  2012 Z Wave Europe GmbH  Goldbachstr  13  09337 Hohenstein Ernstthal  Germany  www zwaveeurope com    Cawove    Z Wave products are supposed to work out of the box after inclusion  however certain configuration can adapt the function better  to user needs or unlock further enhanced features     IMPORTANT  Controllers may only allow configuring signed values  In order to set values in the range 128     255 the value sent in  the application shall be the desired value minus 256  For example  to set a parameter to 200 it may be needed to set a value of  200 minus 256   minus 56  In case of a two byte value the same logic applies  Values greater than 32768 may needed to be given  as negative values too     Blinking Behavior  Parameter Number 2  Parameter Size 2  This is a double byte value  The LSB defines the total  time the device need to blink  The value if set in secon
2.  either be solid on or off  depending on if the switch is on or off  after the button was last pressed     Operating the device    The switch is operated by the local switch button or wireless via Z Wave  The click on the switch sets the switch on or off     The Aeon Labs Inline Smart Energy Switch can report wattage energy usage or kWh energy usage to a Z Wave gateway or  controller when requested  If this function is supported by the gateway controller  the energy consumption will be displayed in the  user interface of the gateway controller  Please consult the operation manual for these gateways controllers for specific  instructions     Node Information Frame    NIF The Node Information Frame is the business card of a Z Wave device  It contains information about the device type and the  technical capabilities  The inclusion and exclusion of the device is confirmed by sending out a Node Information Frame  Beside this  it may be needed for certain network operations to send out a Node Information Frame     A single click at the Inclusion Exclusion switch sends a Node Information Frame     LED Control    e The LED on this device will blink if it is currently not paired into a Z Wave network   e If the Aeon Labs Inline Smart Energy Switch was successfully included to a Z Wave network  the Status Indication LED will either  be solid on or off  depending on if the switch is on or off  after the button was pressed     Associations    A Z Wave devices control other Z Wave devices
3.  or use a Z Wave Controller  The status is shown by the  status LED at the device      c  2012 Z Wave Europe GmbH  Goldbachstr  13  09337 Hohenstein Ernstthal  Germany  www zwaveeurope com    lowa     Behavior within the Z Wave network      On factory default the device does not belong to any Z Wave network  The device needs to join an existing wireless network to  communicate with the devices of this network  This process is called Inclusion  Devices can also leave a network  This process is  called Exclusion  Both processes are initiated by the primary controller of the Z Wave network  This controller will be turned into  exclusion respective inclusion mode  Please refer to your primary controllers manual on how to turn your controller into inclusion  or exclusion mode  Only if the primary controller is in inclusion or exclusion mode  this device can join or leave the network   Leaving the network   i e  being excluded   sets the device back to factory default     If the device already belongs to a network  follow the exclusion process before including it in your network  Otherwise inclusion of  this device will fail  If the controller being included was a primary controller  it has to be reset first     To include this device with your Z Wave controller simple bring it in the inclusion mode and click the Inclusion Exclusion button at  the Aeon Labs Inline Smart Energy Switch once  If this device was successfully included to a Z Wave network  the Status Indication  LED will
4. Cawove     x     AEO SES3 EU b    Inline Smart Energy Switch    Firmware Version   2 25    Quick Start    I   This is a Z Wave actuator     Inclusion and Exclusion are confirmed by a single click on the button  If the Aeon Labs Inline Smart Energy Switch is not included  into any Z Wave network  the LED will be blinking continually The device supports secure communication   Please refer to the chapters below for detailed information about all aspects of the products usage        Product description    The Aeon Labs Inline Smart Energy Switch is a Z Wave light switch specifically used to enable Z  Wave commands and control   on off  a device that is connected to a standard Schuko Wall Outlet     It can also report immediate wattage consumption or kWh energy usage over a period of time  The wireless module is powered  from the mains supplys  In the event of power failure  non volatile memory retains all programmed information relating to the  units operating status  This device support secure communication when included by a controller that also supports secure  communication  The device will then send all commands as secure commands unless the receiving device can not accept them   Then the command is send the normal way automatically     Installation Guidelines       Z Wave switch    This device be plugged between every Standard Schuko wall outlet and the electrical appliance with maximum load of 3500W  To  switch the plugged device on or off simply push the local button once
5. ds  The MSB defines the on off interval of the blinking  The unit is 0 1 s   Value Description  1    255 This is a double byte value  The LSB defines the total time the device need to blink  The value if set in seconds  The    MSB defines the on off interval of the blinking  The unit is 0 1 s     Current Overload Protection  Parameter Number 3  Parameter Size 1  Load will be closed when the Current  overrun  US  15 5A  other country  16 2A  and the time more than 2 minutes  O disabled  1 enabled      Value Description  0 Active Overload Protection  Default   1 Deactivate Overload Protection    Output Load Status  Parameter Number 20  Parameter Size 1  Configure the output load status after re power    on   Value Description  0 last status  Default   1 always on  2 always off    Notification on Status Change  Parameter Number 80  Parameter Size 1  Defines the automated status  notification of an associated device when status changes  O nothing  1 hail CC  2 basic CC report      Value Description   0 nothing  Default   1 hail   2 basic CC report    Configure the state of red LED  Parameter Number 81  Parameter Size 1   Value Description    0 The LED will follow the status  on off  of its load   Default   1 When the state of Switch   s load changed  The LED will follow the status  on off  of its load  but the red LED will turn off    after 5 seconds if there is no any switch action     Enables disables parameter 91 92  Parameter Number 90  Parameter Size 1      c  2012 Z Wave Eu
6. hal  Germany  www zwaveeurope com    lowe    4 Meter Report for Watt       8 Meter Report for kWh    Set 111 113 to default  Parameter Number 110  Parameter Size 1     Value Description  0 Set to default  Default     Send Interval for Reporting Group 1  Parameter Number 111  Parameter Size 4  Defines the time interval  when the defined report of Reporting Group 1 is sent out        Description    Interval  Default 720        Send Interval for Reporting Group 2  Parameter Number 112  Parameter Size 4  Defines the time interval  when the defined report of Reporting Group 2 is sent out     Description    Interval  Default 720        Send Interval for Reporting Group 3  Parameter Number 113  Parameter Size 4  Defines the time interval  when the defined report of Reporting Group 3 is sent out     Value Description    0     32000 Interval    Partner ID  Parameter Number 200  Parameter Size 1     Value Description  0 Aeon Labs Standard  Default   1 AT amp T    Enable disable Configuration Locked  Parameter Number 252  Parameter Size 1     Value Description  0 Deactivate configurationlock  Default              1 Activate configurationlock    Technical Data    Explorer Frame Support Yes     c  2012 Z Wave Europe GmbH  Goldbachstr  13  09337 Hohenstein Ernstthal  Germany  www zwaveeurope com    lowe    SDK 6 51 00       6  c  2012 Z Wave Europe GmbH  Goldbachstr  13  09337 Hohenstein Ernstthal  Germany  www zwaveeurope com    
7. rope GmbH  Goldbachstr  13  09337 Hohenstein Ernstthal  Germany  www zwaveeurope com    lowe    Value Description  0 Enabled parameter 91 92  Default        1 Disabled parameter 91 92    Minimum Change to send Report  Watt   Parameter Number 91  Parameter Size 2  The value represents  the minimum change in wattage for a Report to be sent     Value Description    0     32000 The value represents the minimum change in wattage   Default 25        Minimum Change to send Report      Parameter Number 92  Parameter Size 1  The value represents the  minimum change in wattage Percent for a report to be sent   Valid values 0 100     Description    The value represents the minimum change in wattage Percent   Default 5        Set 101 103 to default  Parameter Number 100  Parameter Size 1     Value Description  0 set to default  Default   1 nothing    Report type send in Reporting Group 1  Parameter Number 101  Parameter Size 4  Defines the type of  report sent for the Reporting Group 1     Report Type send in Reporting Group 2  Parameter Number 102  Parameter Size 4  Defines the type of  report sent for the Reporting Group 2     Value Description  2 Mutlisensor Report          4 Meter Report for Watt  8 Meter Report for kWh       Report Type send in Reporting Group 3  Parameter Number 103  Parameter Size 4  Defines the type of  report sent for the Reporting Group 3     Value Description  2       Mutlisensor Report    4  c  2012 Z Wave Europe GmbH  Goldbachstr  13  09337 Hohenstein Ernstt
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
  ダウンロード  datasheet PDF  Documentation of the ELP software  User Manual English - Velopex International  Guide d`utilisation Revacil Spa  AudioSource Amp Seven T User's Manual  Manual de Instalación y Operación VH856  users manual.indd - Ford  Worldwide Lighting W83146C24 Instructions / Assembly    Copyright © All rights reserved. 