APC BX700U-FR uninterruptible power supply (UPS)
Contents
1. Back UPS BX700U Series by Schneider Electric Safety and General Information Inspect the package contents upon receipt Notify the carrier and dealer if there is any damage Read the following reminders before installing the UPS This UPS is intended for indoor use only Connect the UPS power cable directly to a wall outlet Do not use surge protectors or extension cords e When grounding cannot be verified disconnect the equipment from the AC power outlet before installing or connecting to other equipment Reconnect the power cord after all connections are made e Servicing of batteries should be performed by Schneider Electric IT SEIT Customer Support only When replacing battery the UPS must be OFF and its AC inlet unplugged Do not dispose of batteries in a fire The batteries may explode Do not open or mutilate batteries They contain an electrolyte that is toxic and harmful to the skin and eyes To avoid harmful injury due to energy hazard remove wrist watches and jewelry such as rings when replacing the batteries Use tools with insulated handles Replace batteries with the same number and type of batteries as originally installed in the equipment Features Q Power button Q Telephone Network port BX700UI BX700U AZ BX700U MS only Battery connector Q AC Power Inlet e Circuit breaker Battery Backup Surge Protection outlets USB port See outlet type and quantity breakdown for each model on the gr
2. The AC input is present but is no powering the load Contact SEIT Technical Support Long beep every Over temperature Protected The Back UPS has 4 seconds overheated and has shut down Unplug connected devices one at a time or wait a few hours for system to cool down the other end to a computer with access to the web ne 6 Specifications Edition in the Filter by Software Firmware drop down menu Select the appropriate operating system Follow directions to download the software Automatic Voltage Regulation Automatic Voltage Regulation boosts trims the AC voltage when it drops exceeds safe levels This allows the equipment plugged into the unit to operate during low high voltage conditions conserving the battery power in the event of a power cut The Back UPS will switch to battery power if the input voltage level becomes too low high for the Automatic Voltage Regulation to compensate or if the AC power is distorted If the Back UPS switches to battery power too frequently or too infrequently adjust the transfer voltage and sensitivity settings 1 Ensure the Back UPS is off Plug it into AC power 2 Press and hold the ON OFF button until the LED repeatedly flashes The unit is now in Program Mode 3 Release the button The LED will indicate the current setting by flashing once twice or three times per second and emitting audible beeps 4 If the button is not pressed within five seconds the Back UPS wi
3. Audible Alarm Condition On Off On line The Back UPS is supplying AC power to the connected equipment Constant Tone On Line Overload The power being used by the connected equipment has exceeded the capacity of the unit Disconnect some equipment Constant beeping Over temperature Warning The unit is overheating and will shut down if the temperature is not lowered Disconnect some of the connected equipment On 4 beeps repeated every 30 On Battery The Back UPS is supplying battery Off during 4 beeps seconds power Flashing Rapid Beeping Low Battery Warning The Back UPS has 2 every 1 2 second minutes of runtime remaining Constant tone Bad Battery Detected The battery needs to be charged or is at end of life Chirp every 2 seconds Charger Warning The Back UPS has experienced an internal problem but is still providing power to the connected equipment Contact Schneider Electric IT SEIT Technical Support off Short beep every Low Battery Shutdown During On Battery 4 seconds operation the battery power was almost completely exhausted and the Back UPS is waiting for AC power to return to normal Constant Tone On Battery Overload The connected equipment requires more power than provided by the Back UPS battery Unplug devices one at a time to remove overload If the problem is not corrected contact SEIT Technical Support Constant Tone Charger Fault Back UPS has an internal problem
4. contact Schneider Electric IT SEIT Customer Support through the Schneider Electric web site www apc com a b C d Note the model number and serial number and the date of purchase The model and serial numbers are located on the rear panel of the unit and are available through the LCD display on select models Call SEIT Customer Support and a technician will attempt to solve the problem over the phone If this is not possible the technician will issue a Returned Material Authorization Number RMA Tf the unit is under warranty the repairs are free Service procedures and returns may vary internationally Refer to the Schneider Electric web site for country specific instructions 2 Prepare to troubleshoot the problem over the phone If this is not successful and the unit is still under warranty the Technical Support Representative will provide all necessary information to return the unit for replacement APC by Schneider Electric IT Customer Support Worldwide For country specific customer support go to the APC by Schneider Electric web site www apc com EN 990 5398 002 06 2014 2014 APC by Schneider Electric APC the APC logo Back UPS and PowerChute are owned by Schneider Electric Industries S A S or their affiliated companies All other trademarks are property of their respective owners
5. al unit back due to the assignment of asset tags and set depreciation schedules must declare such a need at first contact with an SEIT Technical Support representative SEIT will ship the replacement unit once the defective unit has been received by the repair department or cross ship upon the receipt of a valid credit card number The customer pays for shipping the unit to SEIT SEIT pays ground freight transportation costs to ship the replacement unit to the customer Input Voltage 220 240 VAC Frequency 50 60 Hz 3 Hz Auto sensing Brownout Transfer Over voltage Transfer 140 VAC typical 300 VAC typical Output UPS Capacity total 700 VA 390 W Voltage On Battery 230 Vac rms Frequency On Battery 50 60 Hz 1 Hz Transfer Time 4ms typical Protection AC Input Resettable circuit breaker Battery Type maintenance free lead acid 12V 7 2 AH Average Life The battery typically lasts for three to five years Environmental factors impact battery life Elevated temperatures high humidity poor quality mains power and frequent short duration discharges will shorten battery life The battery in the Back UPS BX700U Series is not user replaceable Contact SEIT Technical Support for a list of authorized service centers near you Typical Recharge Time 6 hours Physical Net Weight 6 0 kg Dimensions H x W x D 19 9 cm x 11 5 cm x 25 6 cm Troubleshooting and Service 1 If the problem persists
6. aphic below Outlet Type and Quantity BX700U AZ x3 Model BX700U FR Back UPS BX700U GR BX700U MS BX700UI For BX700UI and BX700U MS only IEC jumper cable for PC connection A Operational Features Install PowerChute Software To install PowerChute Personal Edition PCPE software connect a USB cable to the data port on the UPS and On the computer go to www apc com tools download Select Software Upgrades PowerChute Personal User Guide Connect the Battery 1 Connect the battery by pulling the battery connector handle down and then pushing it into the unit Connect the Back UPS BX700U FR GR AZ models power y T2 cable directly to a wall outlet Do not use surge protectors or extension cords For BX700UI and BX700U MS replace PC s input cord with the jumper cable and use PC s input cord to connect UPS Note BX700LI MS comes with an extra power cord for connection to a wall outlet Press the ON OFF button to turn on the unit The green Power On indicator confirms that the Back UPS is on and ready to provide protection The Back UPS should charge for at least 10 hours to ensure sufficient runtime The unit is being charged whenever it is connected to AC power whether the unit is turned ON or OFF 4 Status Indicators LED
7. ll exit the Program Mode No load Shutdown If the UPS is operating on battery power and detects that the connected equipment is using less than 15 W of energy for more than 15 minutes it will shut down to conserve energy When the UPS is reconnected to AC power the UPS will automatically switch on Voltage Input LED Audible Sensitvity Voltage No load Flashing Indicator Setting Range Shutdown Description Once per None Low 140 300 Disabled The Back UPS will switch to battery second power less often Once per 4beeps per Low 140 300 Enabled The Back UPS will switch to battery second second power less often Twice per None Medium 140 300 Disabled Use when the input AC power is normal second without any fluctuation in voltage levels Twice per 4beepsper Medium 140 300 Enabled Use when the input AC power is normal second second factory without any fluctuation in voltage levels default Three times None High 150 290 Disabled The Back UPS will switch to battery per second power during any small fluctuation in voltage Three times 4beepsper High 150 290 Enabled The Back UPS will switch to battery per second second power during any small fluctuation in voltage Warranty Register your product on line http warranty apc com The standard warranty is two 2 years from the date of purchase SEIT standard procedure is to replace the original unit with a factory reconditioned unit Customers who must have the origin