APC BX1400U-FR uninterruptible power supply (UPS)
Contents
1. BX950U MS BX1400U MS BX950UI BX1400UI Q Circuit breaker Battery Backup Surge Protection outlets See outlet type Q Online LED Battery LED Back UPS BX950U FR BX1400U FR User Guide Connect the Battery 1 Connect the battery by pulling the battery connector handle down and then pushing it into the unit 2 Connect the Back UPS BX950U FR BX1400U FR power cable directly to a wall outlet Do not use surge protectors or extension cords 3 Press the ON OFF button to turn on the unit The green Power On indicator confirms that the Back UPS is on and ready to provide protection The Back UPS should charge for at least 10 hours to ensure sufficient runtime The unit is being charged whenever it is connected to AC power whether the unit is turned ON or OFF 4 Status Indicators LED Indicator The On Line LED illuminates green Audible Alarm Status Terminates Audible Alarm INone Power On IN A The Back UPS is supplying AC power to connected equipment On Battery The Back UPS is supplying battery power to battery backup outlets The On Line LED illuminates green The LED is not illuminated during the beeps The On Line LED flashes The Back UPS lgreen emits rapid beeping once every second Back UPS beeps 4 The beeping stops when times every 30 JAC power is restored or seconds the Back UPS is turned off Low Battery
2. by Schneider Electric Safety and General Information Inspect the package contents upon receipt Notify the carrier and dealer if there is any damage Read the following reminders before installing the UPS This UPS is intended for indoor use only Connect the UPS power cable directly to a wall outlet Do not use surge protectors or extension cords e When grounding cannot be verified disconnect the equipment from the AC power outlet before installing or connecting to other equipment Reconnect the power cord after all connections are made e Servicing of batteries should be performed by Schneider Electric IT SEIT Customer Support only When replacing battery the UPS must be OFF and its AC inlet unplugged Do not dispose of batteries in a fire The batteries may explode Do not open or mutilate batteries They contain an electrolyte that is toxic and harmful to the skin and eyes To avoid harmful injury due to energy hazard remove wrist watches and jewelry such as rings when replacing the batteries Use tools with insulated handles Replace batteries with the same number and type of batteries as originally installed in the equipment 3 Features Outlet Type and Quantity BX950U AZ ea BX1400U AZ a Model x6 Back UPS BX950U FR BX1400U FR BX950U GR BX1400U GR
3. Frequency on Battery 50 60 Hz 1Hz Transfer Time 8 ms typical Protection AC Surge Protection Full time 273 Joules and Filtering AC Input Resettable circuit breaker Type maintenance free 9 Ah 12 Vx1 7 2 Ah 24 V 12 Vx2 lead acid i g The battery typically lasts for two to five years Environmental factors impact battery life Elevated temperatures high humidity poor quality mains power Batter and frequent short duration discharges will shorten y Average Life battery life The battery in the Back UPS BX950U FR BX1400U FR is not user replaceable Contact SEIT Technical Support for a list of authorized service centers near you Typical Recharge Time 8 Hours Physical Net Weight 8 kg 12 kg Dimensions H x W x D 21 5 cm x 13 cm x 33 6 cm Troubleshooting and Service 1 If the problem persists contact Schneider Electric IT SEIT Customer Support through the Schneider Electric web site www apc com a Note the model number and serial number and the date of purchase The model and serial numbers are located on the rear panel of the unit and are available through the LCD display on select models b Call SEIT Customer Support and a technician will attempt to solve the problem over the phone If this is not possible the technician will issue a Returned Material Authorization Number RMA c Ifthe unit is under warranty the repairs are free d Service procedures and returns may vary internationally Refer to the Schneider Electric web
4. PowerChute Personal Edition PCPE software connect a USB cable to the data port on the UPS and the other end to a computer with access to the web On the computer go to www apc com tools download Select Software Upgrades PowerChute Personal Edition in the Filter by Software Firmware drop down menu Select the appropriate operating system Follow directions to download the software Automatic Voltage Regulation Automatic Voltage Regulation boosts trims the AC voltage when it drops exceeds safe levels This allows the equipment plugged into the unit to operate during low high voltage conditions conserving the battery power in the event of a power cut The Back UPS will switch to battery power if the input voltage level becomes too low high for the Automatic Voltage Regulation to compensate or if the AC power is distorted If the Back UPS switches to battery power too frequently or too infrequently adjust the transfer voltage and sensitivity settings 1 Ensure the Back UPS is off Plug it into AC power 2 Press and hold the ON OFF button until the LED repeatedly flashes The unit is now in Program Mode 3 Release the button The LED will indicate the current setting by flashing once twice or three times per second and emitting audible beeps 4 If the button is not pressed within five seconds the Back UPS will exit the Program Mode No load Shutdown If the UPS is operating on battery power and detects that the c
5. site for country specific instructions 2 Prepare to troubleshoot the problem over the phone If this is not successful and the unit is still under warranty the Technical Support Representative will provide all necessary information to return the unit for replacement Warranty Register your product on line http warranty apc com The standard warranty is two 2 years from the date of purchase SEIT standard procedure is to replace the original unit with a factory reconditioned unit Customers who must have the original unit back due to the assignment of asset tags and set depreciation schedules must declare such a need at first contact with an SEIT Technical Support representative SEIT will ship the replacement unit once the defective unit has been received by the repair department or cross ship upon the receipt of a valid credit card number The customer pays for shipping the unit to SEIT SEIT pays ground freight transportation costs to ship the replacement unit to the customer APC by Schneider Electric IT Customer Support Worldwide For country specific customer support go to the APC by Schneider Electric web site www apc com EN 990 5331 08 2014 2014 APC by Schneider Electric APC the APC logo Back UPS and PowerChute are owned by Schneider Electric Industries S A S or their affiliated companies All other trademarks are property of their respective owners
6. onnected equipment is using less than 15 W of energy for more than 15 minutes it will shut down to conserve energy When the UPS is reconnected to AC power the UPS will automatically switch on Voltage Input LED Audible Sensitivity Voltage No load Flashes Indicator Setting Range Shutdown Description Green None Low 150 280 Disabled Use this setting with equipment that is less sensitive to fluctuations in voltage or waveform distortions Green 4 beeps per Low 150 280 Enabled Use this setting with equipment that is second less sensitive to fluctuations in voltage or waveform distortions Red None Medium 155 280 Disabled Use this setting for normal operation conditions Red 4 beeps per Medium 155 280 Enabled Use this setting for normal operation second factory conditions default Green and None High 160 280 Disabled Use this setting when connected Red equipment is sensitive to voltage fluctuations or waveform distortions Greenand 4beepsper High 160 280 Enabled Use this setting when connected Red second equipment is sensitive to voltage fluctuations or waveform distortions Specification BX950U FR BX1400U FR Voltage 230 Vac nominal Tipat Frequency 50 60 Hz 3Hz auto sensing p Brownout Transfer 155 Vac typical Over voltage Transfer 280 Vac typical UPS Capacity total 950 VA 480 W 1400 VA 700 W Output Voltage On Battery 230 Vac rms step approximated sinewave
7. warning The Back UPS is supplying battery power to the battery backup outlets and the battery is near a total discharge state Replace Battery The beeping stops when IAC power is restored or the Back UPS is turned off e The Battery LED Constant tone The Back UPS is turned The battery is disconnected flashes red loff The battery needs to be charged Battery and On Line or replaced LEDs flash alternately Overload Shutdown None Constant tone The Back UPS is turned While operating on battery off power an overload condition has occurred in one or more of the battery backup outlets Sleep Mode While operating on battery power the battery is completely The Back UPS beeps once every four seconds INone e AC power is restored e AC power is not restored within 32 discharged seconds The Back UPS will awaken once e The Back UPS is AC power is restored turned off Overload Alarm Constant tone The equipment connected to the Back UPS is drawing more power than the voltage rating allows The Battery LED illuminates red Alarm stops when Inonessential equipment is disconnected from the Battery Backup outlets Specifications C On Off button and quantity breakdown for each model from the table on the left AC power inlet Battery connector e Telephone Network oO USB port port A Operational Features Install PowerChute Software To install