Home
ASUS Z10PE-D16
Contents
1. a SI o DIMMTRIP1 O E 1 2 2 3 YG ol i Lo y TOOT Enable Disable a kei Default Z10PE D16 Series Thermaltrip setting RAID configuration utility selection 3 pin RAID SEL1 This jumper allows you to select the RAID configuration utility to use when you create disk arrays Place the jumper caps over pins 1 2 to use the third party software LSI MegaRAID software RAID Configuration Utility otherwise place the jumper caps to pins 2 3 to use the Intel Rapid Storage Technology enterprise SATA Option ROM Utility SUS OLH H H MK RAID_SEL1 E m O 1 2 2 3 Dee O o 5 pa Co Ta 2 sa 3 Party Intel 2 U mai M mi Default Z10PE D16 Series RAID setting Chapter 2 Hardware Information 8 BMC Setting 3 pin BMC ENI1 This jumper allows you to enable or disable the ASMB8
2. Cn Enam h EE LAN34_LED1 00 7 E eie k Ng i Xx Z GO Hd oo OE cf Z Ziz Zz b Tai IL LiL L I am i ii ii ee Se a K O lt O XIX X o O oO o D DDD se E LO LLL H RJ I 7 Do e Hm L om BE m LILI PINI Z10PE D16 Series LAN3 amp LAN4 LED Z The 10G LAN LED connector is only available on Z10PE D16 10G 2T e Z10PE D16 Series 2 37 8 Power Supply SMBus connector 5 pin PSUSMB1 This connector allows you to connect SMBus System Management Bus to the PSU power supply unit to read PSU information Devices communicate with an SMBus host and or other SMBus devices using the SMBus interface f ES e PSUSMB1 I2C1SCL I2C1SDA I2C1ALT GND 3 3V U ih H H HI O on I br n I e U 8E oi Z10PE D16 Series Power supply SMBus connector Z Th
3. ho KE RAPE RGF h lanadi O SMART_PSU1 2 3 Disable Default 5 ME firmware force recovery setting 3 pin ME RCVRT1 This jumper allows you to force Intel Management Engine ME boot from recovery mode when ME becomes corrupted lihai O ox NE sii i Z10PE D16 Series ME recovery setting Z10PE D16 Series ME RCVR1 1 2 2 3 Normal Enable Default recovery mode 2 29 DDR4 thermal event setting 3 pin DIMMTRIP1 This jumper allows you to enable or disable DDR4 DIMM thermal sensing event pin Ba 1
4. GND NC ia HH HLA USB 5V USB_P6 USB_P6 USB56 3 IN mg E GND 8 Hom i BP Ann anak Z10PE D16 Series USB 2 0 connector USB 5V USB_P5 USB_P5 Z10PE D16 Series 2 35 USB 3 0 connector 20 1 pin USB3 34 This connector allows you to connect a USB 3 0 module for additional USB 3 0 front or rear panel ports With an installed USB 3 0 module you can enjoy all the benefits of USB 3 0 including faster data transfer speeds of up to 5Gbps faster charging time for USB chargeable devices optimized power efficiency and backward compatibility with USB 2 0 PARA Reed ee TE i hi LH h o n 2 a 20 40 Je 2 36 Les ar a HIN IntA P1 SSRX IntA P1 SSR
5. CLKRUN SERIRQ NC GND NC LAD2 LAD1 GND NC ih H HH TPM1 PIN 1 NC 3VSB LCLK LAD3 3V LADO GND LPCPD LFRAME LREST UI mm Cio m Mm Bl HH VGA connector 10 1 pin VGA_HDR1 This connector supports the VGA High Dynamic Range interface h h h h VGA HDR1 4 DDC CLK i rk V_SYNC H_SYNC mn A DDC_DATA 3 ol GND GND S GND GND de Blue 5 Bi Green Red LJ aan N O i PIN 1 O C7 O 7 ND Ban am i oe Cn 1 Se Mr Z10PE D16 Series VGA connector 2 39 12 ATX power connectors 24 pin EATXPWR1 8 pin EATX12V1 8 pin EATX12V2 4 pin EATX12V_NVDIMM1 These connectors are for the ATX power supply plugs The power supply plugs are designed to fit these connectors in only one orientation Find
6. Analaa mala n TF Yi E BMC EN1 1 2 2 3 Ci CA Enable Disable Default z1 OPE D16 Senes BMC setting Z10PE D16 Series 2 31 2 8 Connectors 2 8 1 Rear panel connectors 1 PS 2 keyboard mouse port purple green This port is for a PS 2 keyboard or mouse 2 Video Graphics Adapter VGA port This port is for a VGA monitor or other VGA compatible devices 3 RJ 45 ports for 10G LAN of Z10PE D16 2L 10G 2T Z10PE D16 10G 2T or GbE LAN for Z10PE D16 4L These ports allows 10 Gigabit or Gigabit connection to a Local Area Network LAN through a network hub Refer to the table LAN port LED below for the LAN port LED indications 4 RJ 45 ports for LAN Z10PE D16 2L 10G 2T Z10PE D16 4L and Z10PE D16 These ports allows Gigabit connection to a LAN through a network hub Refer to the table below for the LAN port LED indications 5 RJ 45 port for iKVM This RJ 45 port functions only when you enable ASMB8 controller 6 Power on Button Press this button to turn on the system 7 Lo
7. Eh a 8 Kol 2 SPEAKER Doko y 4 AA Eee 5 _ Gaga 5338 504JJ30 wo Bai bo aZz053222 4 00N H 1 PNTE o KaU a orvon a Ze c uu F3a3783 KJ aQ 56 96 o T O 2 CI Hc o mA p 2a ii Oo Z10PE D16 Series System panel connector 1 System power LED 3 pin PLED This 3 pin connector is for the system power LED Connect the chassis power LED cable to this connector The system power LED lights up when you turn on the system power and blinks when the system is in sleep mode 2 Message LED 2 pin MLED This 2 pin connector is for the message LED cable that connects to the front message LED The message LED is controlled by Hardware monitor to indicate an abnormal event occurance 3 System warning speaker 4 pin SPEAKER This 4 pin connector is for the chassis mounted system warning speaker The speaker allows you to hear system beeps and warnings 4 Hard disk drive activity LED 2 pin HDD LED This 2 pin connector is for the HDD Activity LED Connect the HDD Activity LED cable to this connector The HDD LED lights up or fla
8. ccceeecceceessssceeceessseeececessteeeeessseseeeeeeseas 2 34 Chapter 3 Powering Up 3 1 3 2 Starting up for the first WING mami 3 2 Powering off the computer moon 3 3 3 2 1 Using the OS shut down function 3 3 3 2 2 Using the dual function power Switch 3 3 Chapter 4 BIOS Setup 4 1 4 2 4 3 4 4 Managing and updating your BIOS oom 4 2 4 1 1 ASUS CrashFree BIOS 3 utility 4 2 4 1 2 ASUS EZ Plast Utility srne 4 3 4 1 3 BUPDATER OHY siiiinnesactiniiemnsthtohodeintnnsdctabmsiiecinnimimeauuatbenaineies 4 4 BIOS setup program oooooooo oo oom 4 6 4 2 1 BIOS menu screen oooco o Wo oom WWW Woman 4 7 42 2 Menu an an Pn NAN 4 7 42 3 an te omanneesenewnreenesinteses 4 8 4 2 4 Submenu items sr dense ss cnnrenssnsamercucenntiosianiemeiestirhannnndeinscseameonsamnoiatanss 4 8 4 2 5 Navigation KOS momen maen aa 4 8 4 2 6 General TSN ais oetrcsresrsosmncustenasosawenidtsnnesionecueshbtmeumanestismmean seme innans 4 8 4 2 7 Configuration fields scsccserat cansiaistciasiadceninstanknssnchitedsnceuinettadsenmstaneens 4 8 4 2 8 POP UP WING OW esga A 4 8 4 2 9 OCT DA a cube anon ana anamansebaB aa Bi 4 8 Man MENU na enero ee errr ee ena ren ieee aero 4 9 4 3 1 System Date Day XX XX XXXXJ ooo Wo mna 4 9 4 3 2 System Time KKM anatomi sen agitondi mna aikan mantan 4 9 Advanced an naa 4 10 4 4 1 AG PS FS casino antam akan tabah anakan ana ama 4 11 4 4 2 Ne ai 4 11 4 4 3 NCT6779D Super IO Configura
9. CSM Support Enabled This option allows you to enable or disable CSM Support Configuration options Disabled Enabled GateA20 Active Upon Request This allows you to set the GA20 option Configuration options Upon Request Always Option ROM Messages Force BIOS This allows you to set the display mode for option ROM Configuration options Force BIOS Keep Current Boot Option filter Legacy only This option allows you to control the Legacy UEFI ROMs priority Configuration options UEFI and Legacy Legacy only UEFI only Network Storage Video Legacy This option allows you to control the execution of UEFI and Legacy PXE Storage Video OpROM Configuration options UEFI Legacy Other PCI devices Legacy This item determines the OpROM execution policy for devices other than Network Storage or Video Configuration options UEFI Legacy Z10PE D16 Series 4 21 4 22 4 4 11 Trusted Computing Aptio Setup Utility Copyright C 2013 American Megatrends Inc Security Device Support Configuration Security Device Support Disabled Allows you to enable or disable the BIOS support for security device Configuration options Disabled Enabled Chapter 4 BIOS Setup 4412 USB Configuration Aptio Setup Utility Copyright C 2013 American Megatrends Inc Legacy USB Support Legacy USB Support Enabled Allows you to enable or disable Legacy USB device support Config
10. 2 From the Shutdown Event Tracker select the option that best describes why you want to shut down the computer 3 Ensure that the Planned check box is checked 4 If necessary key in comments 5 Click OK Using Windows Server 2012 1 Press lt Ctrl gt lt Alt gt lt Del gt 2 Click on the Power icon on the lower right side of the screen 3 Select Shut down 4 In the Shutdown Event Tracker select the Other Planned option in the selection lists Otherwise select the option that best describes why you want to shut down the computer 5 Click Continue 3 2 2 Using the dual function power switch While the system is ON press the power switch for less than four seconds to put the system to sleep mode or to soft off mode depending on the BIOS setting Pressing the power switch for more than four seconds lets the system enter the soft off mode regardless of the BIOS setting Z10PE D16 Series BIOS Setup This chapter tells how to change the system settings through the BIOS Setup menus Detailed descriptions of the BIOS parameters are also provided 4 2 4 1 Managing and updating your BIOS The following utilities allow you to manage and update the motherboard Basic Input Output System BIOS setup 1 ASUS CrashFree BIOS 3 To recover the BIOS using a bootable USB flash disk drive when the BIOS file fails or gets corrupted 2 ASUS EzFlash Updates the BIOS using a USB flash disk 3 BUPDATER
11. Configuration options Auto Floppy Forced FDD Hard Disk CD ROM 4413 iSCSI Configuration Allows you to configure the iSCSi parameters Aptio Setup Utility Copyright C 2013 American Megatrends Inc iSCSI Initiator Name 4 24 Chapter 4 BIOS Setup 4 5 IntelRCSetup menu The IntelRCSetup menu items allow you to change the processor and chipset settings Aptio Setup Utility Copyright C 2013 American Megatrends Inc gt Processor Configuration Z10PE D16 Series 4 25 4 26 4 5 1 Processor Configuration Aptio Setup Utility Copyright C 2013 American Megatrends Inc gt Per Socket Configuration Per Socket Configuration Allows you to set the number of cores to enable 0 means all cores Total of 14 cores available Hyper Threading Enabled Allows you to enable or disable the Intel Hyper Threading Technology function When disabled only one thread per activated core is enabled Configuration options Disabled Enabled Execute Disable Bit Enabled XD can prevent certain classes of malicious buffer overflow attacks when combined with a supporting OS Windows Server 2003 SP1 Windows XP SP2 SuSE Linux 9 2 Redhat Enterprise 3 Update 3 Configuration options Disabled Enabled Enable Intel TXT Support Disabled Forces the XD feature log to always return 0 when disabled Configuration options Disabled Enabled VMX Enabled Enables the Vanderpool Technology Takes
12. m Enable Disable Em Use BP mit Default Z10PE D16 Series VGA setting LAN controller setting 3 pin LAN_SW1 LAN_SW2 LAN_SW3 LAN_SW4 These jumpers allow you to enable or disable the onboard LAN_SW1 LAN_SW2 for 1350 AM2 LAN SW3 LAN SW4 for X540 BT2 or 1350 BT2 LAN controllers Set to pins 1 2 to activate the Gigabit LAN feature Refer to the table below for more information about the LAN controller settings PLAN SWI LAN SW2 LAN SW3 LAN SW4 Z10PE D16 2L 10G 2T for 1350 AM2 for X540 BT2 Z10PE D16 10G 2T for X540 BT2 Z10PE D16 4L for 1350 BT2 Z10PE D16 3 PE EEE LAN swi LAN_SW2 E 1 2 26 1 2 2 3 Cd JO El mo Enable Disable Enable Disable Default Default 12 2 3 LAN_SW3 Eis C LAN Sw4 DE 5 i Enable Disable A l fa I ji Default Z10PE D16 Series LAN setting Chapter 2 Hardware Information 4 PMBus 1 2 PSU select jumper 3 pin SMART PSUT1 This jumper allows you to select PSU PMBus version Set to pins 1 2 for PMBus set to pins 2 3 for others
13. AST2400 Display Driver Intel Chipset Device Software Intel 1350 AM4 13507AM27 1210 X540 B1I ASPEED AST2300 ASjI2400 Display Driver Intel R C610 series Chipset SATAYAHGII Intel C610 MEI NULL HECI Driver 4 From the installation window click Next to start the installation Welcome to the InstallShield Wizard for Win2012 The InstallShield R Wizard will install Win2012 on your ick Next computer To continue click WARNING This program is protected by copyright law and 6 22 Chapter 6 Driver Installation 5 Click Install to proceed with the installation Ready to Install the Program The wizard is ready to begin installation Click Install to begin the installation If you want to review or change any of your installation settings click Back Click Cancel to exit the wizard The InstallShield Wizard has successfully installed Win2012 Click Finish to exit the wizard Z10PE D16 Series 6 23 6 24 6 7 Intel Rapid Storage Technology enterprise 4 0 installation This section provides the instructions on how to install the Intel Rapid Storage Technology enterprise 4 0 on the system You need to manually install the Intel Rapid Storage Technology enterprise 4 0 utility on a Windows operating system To install the Intel Rapid Storage Technology enterprise 4 0 utility 1 Restart the computer and then log on with Administrator privileges 2 Insert the motherboard system
14. Allows you to enable or disable the Intel LAN Configuration options Disabled Enabled LAN3 LAN4 Option ROM Support Enabled Allows you to load the Intel LAN ROM Configuration options Disabled Enabled Chapter 4 BIOS Setup 4 4 6 Serial Port Console Redirection Aptio Setup Utility Copyright C 2013 American Megatrends Inc Console Redirection COM1 COM2 Console Redirection Enabled Allows you to enable or disable the console redirection feature Configuration options Disabled Enabled Z The following item appears only when you set Console Redirection to Enabled Console Redirection Settings This item becomes configurable only when you enable the Console Redirection item The settings specify how the host computer and the remote computer which the user is using will exchange data Both computers should have the same or compatible settings Terminal Type VT UTF8 Allows you to set the terminal type VT100 ASCII char set VT100 Extends VT100 to support color function keys et VT UTF8 Uses UTF8 encoding to map Unicode chars onto 1 or more bytes ANSI Extended ASCII char set Bits per second 57600 Selects serial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds Configuration options 9600 19200 38400 57600 115200 Data Bits 8 Configuration options 7 8 Z10PE D16 Series 4 15 Parity None A p
15. GS o0 0 2 Ss sis sis s sis D sis w U QO vuo Uv o oD D oO D o O D m Ccc3 3 3 3 3 3 3 33 3 5 3 3 O 0 O oO o o Oo Oo Oo Oo o Is o Oo 5 222 see see Qe S 2 5 3 3 3 3 m 2 2 z c 2 oO S D 2 DXE Initial Program Load IPL continued on the next page 2 25 Action POST CODE TYPE DESCRIPTION DXE Core Started DXE Drver e Progress NB Execution Environment phase 6A Progress NB 90 Progress BDS stated 96 Progress POIBusEnumeraion SSS 98 Progress Gonsoleinputeonnestevent Normal boot 99 Progress AMI SuperlOstat B Progress JAmtUSBDmerlni OOS BDS Boot Devic 9D Progress AMIUSB Driveri OO Selection phase b6 Progress NVRAMcleanup o Operating system pns 2 26 Chapter 2 Hardware Information 2 1 Jumpers 1 Clear RTC RAM 3 pin CLRTC1 This jumper allows you to clear the Real Time Clock RTC RAM in CMOS You can clear the CMOS memory of date time and system setup parameters by erasing the CMOS RTC RAM data The onboard button cell battery powers the RAM data in CMOS which include system setup information such as system passwords To erase the RTC RAM 1 Turn OFF the computer and unplug the power cord 2 Move the jumper cap from the default pins 1 2 to pins 2 3 Keep the cap on pins 2 3 for about 5 to 10 seconds then move the cap back to pins 1 2 3 Plug the power cord and turn ON the computer 4 Hold down the Del key during the boot process and enter B
16. 4 Select the User Password item and press Enter From the Enter Current Password box key in the current password then press Enter From the Create New Password box key in a new password then press lt Enter gt Confirm the password when prompted To clear a user password Ty 2 Select the Clear User Password item and press lt Enter gt Select Yes from the Warning message window then press lt Enter gt Secure Boot Menu This item allows you to customize the Secure Boot settings Aptio Setup Utility Copyright C 2013 American Megatrends Inc b Key Management Secure Boot Disabled Secure Boot can be enabled if the system is running in User mode with enrolled platform Key EPK or if the CSM function is disabled Configuration options Disabled Enabled Secure Boot Mode Custom Allows you to set the Secure Boot selector Configuration options Custom Standard Chapter 4 BIOS Setup Key Management This item only appears when the item Secure Boot Mode is set to Custom The Key Management item allows you to modify Secure Boot variables and set Key Management page Aptio Setup Utility Copyright C 2013 American Megatrends Inc Default Key Provision Default Key Provision Disabled Configuration options Disabled Enabled Enroll All Factory Default Keys This item will ask you if you want to Install Factory Default secure keys Select Yes if you want to load the d
17. 4 40 4 7 2 View Smbios Event LOG oooooWo o mom Wa 4 41 MONItOr MENU an ena en Kiai 4 42 Security MENU hitam akbar ma hai Kanan ia nanah dan Ainan 4 43 BOOL MENU Sa naa aa NA 4 46 OOM MENU na ai an Na 4 47 en ea an NIA INA 4 48 Vi Contents Chapter 5 RAID Configuration 5 1 5 2 5 3 5 4 Setting Up RAID kaka 5 2 5 1 1 RAID OSINUN Sat bala aa aa 5 2 5 1 2 Installing hard disk drives ooooo WoWoo WWW WWW 5 3 5 1 3 Setting the RAID item in BIOS oo Wo WWW 5 3 5 1 4 RAID configuration utilities oooooWooo 5 3 LSI Software RAID Configuration Utility 5 4 5 2 1 Creating a RAID ea aa ban 5 5 5 2 2 Adding or viewing a RAID configuration ooo 5 11 5 2 3 Initializing the virtual drives ooooooWooWo WoW W WWW 5 12 5 2 4 Rebuilding failed drives ooooW om 5 16 5 2 5 Checking the drives for data consistency oooooo 5 18 5 2 6 Deleting a RAID configuration oooooooooWo 5 21 5 2 7 Selecting the boot drive from a RAID Set ooooooooo 5 22 5 2 8 Enabling WriteCache oooo oo oo ok 5 23 Intel Rapid Storage Technology enterprise SATA SSATA Option ROM Pi Ba 5 25 5 3 1 Cresung RAID Seto ae 5 26 5 3 2 Deleting a RAID Et omset nemu 5 28 5 3 3 Resetting disks to Non RAID ooooooo Woo WWW 5 29 5 3 4 Exiting the Intel Rapid Storage Technology enterprise SATA SSATA Option ROM utility 5
18. 64bit 288 pin module H DDR4 DIMM_A2 64bit 288 pin module E VGA_HDR1 MEMERRG1 MENERRGS DDR4 DIMM_B1 64bit 288 pin module MEMERRH1 MEMERRHE DDR4 DIMM_B2 64bit 288 pin module MEMERRA1 MEMERRA2 MEMERRB1 MEMERRB2 FRNT_FAN2 pi AJ i k ifon LGA2011 3 ERRCPU1 LGA2011 3 Err Wa E ERRCPU2 FA T AAN DDR4 DIMM_F2 64bit 288 pin module DDR4 DIMM_F1 64bit 288 pin module DDR4 DIMM E2 64bit 288 pin module MEMERRF2 MEMERRF1 MEMERRE2 DDR4 DIMM_E1 64bit 288 pin module MEMERRE1 Intel X540BT2 BK_PWRSW1 MEMERRD2 MEMERRD1 MEMERRC2 MEMERRC1 DDR4 DIMM D2 64bit 288 pin module 1 CPU FAN1 1 a ror a N D zZ lt za a DDR4 DIMM_D1 64bit 288 pin module 1 PCIE6 DDR4 DIMM_C2 64bit 288 pin module DDR4 DIMM_C1 64bit 288 pin module FRNT_FAN3 Q EATX12V_NVDIMM1 Sal Od ASUS Z10PE D16 10G 2T Lithium Cell CMOS Power ASPEED sios AST2400 Se eme hT PCIE2 CATTERR1 TPM1 M Super w DOM1_PWA EEE le elelefalefelala 1 0 DI P5VLED1 CIBMCLED1 LAN34_LED1 BII LED1 SMBUS1 RAID KEY1 dak AUX_PANEL1 lefelelelelelela ELEERI EE e PANEL1 AA F seon foe yale Teleels ll NGFF1 EEE EEE ah nuuuunann EEE CEE SBPWR1 CPLD_JTAG1 ME_RCVR1 SMART_PSU1 FRNT_FAN4 PCH_MFG1 DIMMTRIP1 FRNT_FAN5 MIC_EN1 INTRUSION1 LAN Sw3 EEE LAN SW4 EEE EEE BMCEN1 Z10PE D16 Series Z10PE D16 4L DO UD LI
19. Single User IMPORTANT READ BEFORE COPYING INSTALLING OR USING Do not use or load this software and any associated materials collectively the Software until you have carefully read the following terms and conditions By loading or using the Software you agree to the terms of this Agreement If you do not wish to so agree do not install or use the Software Please Also Note If you are an Original Equipment Manufacturer OEM Independent Hardware Vendor IHV or Independent Software Vendor ISV this complete LICENSE AGREEMENT applies 6 1 Intel Chipset Device Software intel Setup Progress Please wait while the following setup operations are performed Installing Driver Intel R C6 10 series X99 chipset PCI Express Root Port 1 8D10 Version 9 4 2 1 014 Installing Driver Intel R C610 series X99 chipset USB Enhanced Host Controller 1 8D26 Version 9 4 2 1014 Click Next to continue lt T setup process A O Intel Chipset Device Software intel Setup Is Complete You must restart this computer for the changes to take effect Would you like to restart the computer now Yes I want to restart this computer now No I will restart this computer later Click Finish then remove any installation media from the drives Select Yes to accept the terms of the License Agreement and continue the process Read the Readme File Information and press Next to contin
20. aa REAR_FAN1 REAR_FAN2 DDR4 DIMM_F2 64bit 288 pin module 2T DDR4 DIMM_F1 64bit 288 pin module Kai a n z lt ey a DDR4 DIMM_E2 64bit 288 pin module MEMERRF2 MEMERRF1 MEMERRE2 MEMERRE1 Intel X540BT2 BK_PWRSW1 Z10PE D16 2L 10G DDR4 DIMM_E1 64bit 288 pin module 0 PCIE6 ASUS Lithium Cell CMOS Power EEE VGA swi PCIE2 P5VLED1 CIBMCLED1 LAN_SW3 EEE LAN_SW4 EEI Tsel BMCEN1 AA oe 2 SBPWR1 CPLD JTAG1 LGA2011 3 DIGI MEMERRD2 MEMERRD1 MEMERRC2 MEMERRC1 DDR4 DIMM_D2 64bit 288 pin module CPU_FAN1 DDR4 DIMM_D1 64bit 288 pin module DDR4 DIMM_C2 64bit 288 pin module DDR4 DIMM_C1 64bit 288 pin module FRNT FAN3 D EATX12V_NVDIMM1 Eel OO ILCMX0256C CLRTC1 RAID_SEL1 HDLED1 SGPIO1EELEEE REM SSGPIO1EELEER EEEE LU TPM1 DOM1_PWRI EEE lele lelalele lal LAN34 LED1 ELEEE AUX_PANEL1 lelelelelelalel ssaa PANEN EE SMBUS1 RAID_KEY1 mod USB56 ME RCVR1 SMART_PSU1 FRNT FAN4 PCH_MFG1 DIMMTRIP1 FRNT_FANS MIC_EN1 INTRUSION1 Chapter 2 Hardware Information Z10PE D16 10G 2T Do HD HD Dol Do ED OD Do bo HD HD bo 0000 pood 41H aman DDR4 DIMM G1 64bit 288 pin module OOOO OOOO ta KB USB78 ATXI ATXA E EATX12V2 EATX12V1 DDR4 DIMM G2 64bit 288 pin module PAPEN FRNT_FAN1 DDR4 DIMM_H1 64bit 288 pin module th DDR4 DIMM_A1 64bit 288 pin module DDR4 DIMM H2
21. 1 way Interleave 2 way Interleave 3 way Interleave 4 way Interleave Rank Interleaving Auto Select different rank interleaving setting Configuration options Auto 1 way Interleave 2 way Interleave 4 way Interleave 8 way Interleave Memory RAS Configuration RAS Mode Disabled Allows you to enable or disable RAS Modes Enabling Sparing and Mirroring is not supported In case enabled Sparing will be selected Configuration options Disabled Mirror Lockstep Mode Memory Rank Sparing Disabled Allows you to enable or disable Memory Rank Sparing Configuration options Disabled Enabled Correctable Error Threshold 32767 Allows you to set the Correctable Error Threshold used for sparing tagging and leaky bucket The range is from 1 to 32767 Patrol Scrub Enabled Allows you to enable or disable Patrol Scrub Configuration options Disabled Enabled Demand Scrub Enabled Allows you to enable or disable Demand Scrub Configuration options Disabled Enabled Z10PE D16 Series 4 31 4 32 4 5 6 IIO Configuration EV DFX Features Disabled Set this option to allow DFX Lock Bits to remain clear Configuration options Disabled Enabled PCle Slot Option ROM Configuration PCle1 PCle2 PCle3 PCle4 PCle6 Option ROM Disabled Allows you to enable or disable the PCle1 PCle2 PCle3 PCle4 PCle6 Option ROM Configuration options Disabled Enabled Intel VT for Directed I O VT d Int
22. 10 support for both Linux and Windows OS Intel Rapid Storage Technology enterprise Option ROM Utility with RAID 0 RAID 1 RAID 10 and RAID 5 support for Windows OS only 5 1 1 RAID definitions RAID 0 Data striping optimizes two identical hard disk drives to read and write data in parallel interleaved stacks Two hard disks perform the same work as a single drive but at a sustained data transfer rate double that of a single disk alone thus improving data access and storage Use of two new identical hard disk drives is required for this setup RAID 1 Data mirroring copies and maintains an identical image of data from one drive to a second drive If one drive fails the disk array management software directs all applications to the surviving drive as it contains a complete copy of the data in the other drive This RAID configuration provides data protection and increases fault tolerance to the entire system Use two new drives or use an existing drive and a new drive for this setup The new drive must be of the same size or larger than the existing drive RAID 10 is data striping and data mirroring combined without parity redundancy data having to be calculated and written With the RAID 10 configuration you get all the benefits of both RAID 0 and RAID 1 configurations Use four new hard disk drives or use an existing drive and three new drives for this setup RAID 5 stripes both data and parity information across three or more
23. 4 x SSATA 3 6 x SATA 3 Intel RSTe RAID O 1 10 5 LSI MegaRAID 0 1 10 x16 Gen3 PCIE6 8 Gens PCIE3 x2 Gen2 1350 AM2 4 Gen3 2 PCIE1 x4 Gen2 x1 AST 2400 LPC ASUS contact information ASUSTeK COMPUTER INC Address 15 Li Te Road Peitou Taipei Taiwan 11259 Telephone 886 2 2894 3447 Fax 886 2 2890 7798 E mail info asus com tw Web site http www asus com Technical Support Telephone 86 21 3842991 1 Fax 86 21 58668722 ext 9101 Online Support http support asus com techserv techserv aspx ASUSTeK COMPUTER INC Taiwan Address 15 Li Te Road Peitou Taipei Taiwan 11259 Telephone 886 2 2894 3447 Fax 886 2 2890 7798 E mail info asus com tw Web site http www asus com tw Technical Support Telephone 886 2 2894 3447 0800 093 456 Online Support http support asus com techserv techserv aspx ASUSTeK COMPUTER INC China Address No 508 Chundong Road Xinzhuang Industrial Zone Minhang District Shanghai China Telephone 86 21 5442 1616 Fax 86 21 5442 0099 Web site http www asus com cn Technical Support Telephone 400 620 6655 Online Support http support asus com techserv techserv aspx A 6 Appendix ASUS contact information ASUS COMPUTER INTERNATIONAL America Address Fax Web site Technical Support Support fax General support Online support 800 Corporate Way Fremont CA 94539 USA 1 510 608 4555 http usa asus com 1 812 284 0883 1 812 282
24. CPU Warning LED ERRCPU1 ERRCPU2 The CPU warning LEDs light up to indicate failure on either CPU1 CPU2 or both PAAA REA i 1G A Til ERRCPU1 ERRCPU2 Ulama Of 3 Bar fico ries ERR CPU LED Hm B Z10PE D16 Se Power LED P5VLED1 This LED lights up when you turn on the system using the Power on button Cc KAA lahh O P5VLED1 fal oO HA m aa Ger Ko oom Z10PE D16 Series 5V Power LED Chapter 2 Hardware Information 5 Location LED LOCLED2 This onboard LED lights up when the Location button on the server is pressed or when triggered by a system management software The Location LED helps visually locate and quickly ident
25. Configuration options Do Nothing Erase Immediately Log EFI Status Codes Error code Disable the logging of EFI Status Codes or log only error code or only progress code or both Configuration options Disabled Both Error code Progress code Bmc network configuration The sub items in this configuration allow you to configure the BMC network parameters Aptio Setup Utility Copyright C 2013 American Megatrends Inc Configuration Address source Configuration Address source DM_LAN1 LAN1 Previous State This item allows you to configure LAN channel parameters statistically or dynamically by BIOS or BMC Unspecified option will not modify any BMC network parameters during BIOS phase Configuration options Previous State Static DynamicBmcDhcp DynamicBmcNonDhcp Z10PE D16 Series 4 37 4 38 View System Event Log This item allows you to view the system event log records IPv6 BMC Network Configuration This item allows you to configure the parameter settings of IPv6 BMC network Aptio Setup Utility Copyright C 2013 American Megatrends IPv6 Display Full Field IPv6 Display Full Field Enable Displays the full or brief IPv6 Field Configuration options Disable Enable IPv6 Display Full Formula Enable Displays the full or brief IPv6 Formula Configuration options Disable Enable IPv6 Display Letter Case Upper Case Displays the uppercase or lowercase letters of the alphabet Con
26. Free Space Type Name Total Size a Disk 1 Partition 1 592 3 GB 584 9GB Primary p Refresh Drive options advanced Setup then proceeds with the OS installation Follow screen instructions to continue Chapter 6 Driver Installation Red Hat Enterprise Linux OS 5 x To load the LSI MegaRAID controller driver when installing Red Hat Enterprise OS 1 2 3 4 Boot the system from the Red Hat OS installation CD At the boot type linux dd then press Enter Select Yes using the Tab key when asked if you have the driver disk then press Enter Main Menu Do you have a driver disk Insert the Red Hat Enterprise RAID driver disk to the USB floppy disk drive select OK then press Enter Insert Driver Disk Insert your driver disk into dev fd0 and press OK to continue The drivers forthe RAID card are installed to the system Z10PE D16 Series 6 5 6 6 D When asked if you will load additional RAID controller drivers select No then press lt Enter gt More Driver Disks Do you wish to load any more driver disks Follow the onscreen instructions to finish the OS installation When the installation is completed DO NOT click Reboot Press lt Ctrl gt lt Alt gt lt F2 gt to switch to the command line interface from graphic user interface Type the following commands when using a Legacy floppy mkdir mnt dri
27. GEE A E SSGPIO1EEDEEEI EEE EEN ros LAN_SW3 EEE oO SBPWR1 CPLD JTAG1 LAN SW4 leis GEEIBMC_EN1 ME RCVR1 SMART PSU1 PCH MFG1 DIMMTRIP1 MIC EN1 INTRUSION1 FRNT FAN4 FRNT FANS 2 6 Chapter 2 Hardware Information Z10PE D16 KB USB78 EATXPWR1 EATX12V2 EATX12V1 Hoon goo ood h0001 G00 H fiom Km semasa BER EE amna AE DDR4 DIMM G2 64bit 288 pin module FRNT_FAN2 FRNT_FAN1 DDR4 DIMM_H1 64bit 288 pin module th DDR4 DIMM_A1 64bit 288 pin module cH DDR4 DIMM_H2 64bit 288 pin module H DDR4 DIMM A2 64bit 288 pin module VGA HDR1 EE sey eae DDR4 DIMM_B1 64bit 288 pin module go Cay oo oo MEMERRH1 r MEMERBHZ DDR4 DIMM_B2 64bit 288 pin module MEMERRA1 MEMERRA2 MEMERRB1 EG FANS MEMERRB2 LGA2011 3 erRRceuID LGA2011 3 Eco Wa j ERRCPU2 E par REAR_FAN2 DDR4 DIMM_F2 64bit 288 pin module MEMERRD2 MEMERRD1 DDR4 DIMM_F1 64bit 288 pin module MEMERRC2 MEMERRC1 DDR4 DIMM_E2 64bit 288 pin module DDR4 DIMM_D2 64bit 288 pin module CPU_FAN1 nu oO a N D z zt at a MEMERRF2 Haa DDR4 DIMM E1 64bit 288 pin module MEMERRE1 7 DDR4 DIMM_D1 64bit 288 pin module DDR4 DIMM_C2 64bit 288 pin module fi san Z10PE D16 PCIE6 DDR4 DIMM_C1 64bit 288 pin module FRNT_FAN3 D EATX12V NVDIMM1 Od Intel 1350 AM2 LAN_SW1 EET GETILAN_Sw2 cee PCIE4 Lithium Cell PCIE3 CMOS Power
28. NA 10 00019 NA 010 720SS NA O 0 O O O 0 u O O 0 0 Uu Uu O Xx Xx 900G 6Vt 00G LVt L00G LOSS NA 600Z 2vt9002 2 00019 NA KXI O0Z OY 0LOzZ zzoss N3 RX anIPAIIG IWI 93 80 L v007Z Xx S A1 9911 p Buimojjoj y JO sjusdwauinbai jepuass y ym WOJUOd 12 201 910 3dOLZ 1t 9L0 3d0LZ 9LA 3d0LZ 12 201 12 914 3dOLZ LI 201 910 3dOLZ oweu jopowg parogadylo aweU JOnpOld snjesedde Buimoyjoj ay asejoap ANYNH3D Aayuno NJONILYH 0880p E2 12 HLS LHOMHYH AUD sseappy HOWE HALNdNOO SNSV redoing ul aniyejussoida1 p zoyny NVMIVL SEL IadIVL NOLIAd PH L 17 OSE ON Av ssolppy ONI HILNJNOI MOLSNSV MoanydEJNUEN 314 03Y9NI 40 HIUVIS NI PA poubisuapun au Mm Anuojuo JO uoyesejpag DF LEOL JOA STOT 81 AE VIO ET AE 9q YO1yeNEpIOG pPI IA VOLJA PLUSO IMPUTIS ap TAM JUIPISITg SULJO JAS WBN S UOSIOg DArjejudsoIdog uonelodo pomsopun sneo Aew py OUDIOFIOJUT SUIPNIOUT PoArooal JJUdIOyIYUI Aue ydaoov Jsnuw ITAP STU T pue QOUDIOFIOJUT NJUWLUIVY ISNEO JOU ABUT IMAP SYL T SUONIPUOD OM SUTMOT OJ oy 0 yoolqns st uonerodo samy DOV Ap JO ST wed yum soyduroo soraap SL uoneULAOJUy Arejuouetddns sxoyerpey peuonuayuun wedang SI ued OOd A suoryed1yIdads SUIMOT OF 9 0 SULIOJUOD 12 D0L 12 9Ld 3dOLZ LI D0L1 9LG 3dOLZ 12 D0
29. Onboard I O x 4 pin headers Connectors 2 x USB 3 0 2 x USB 2 0 Rear I O Connectors 2x GbE LAN ports 2 x 10G BaseT ports 1 x Management LAN port 2 x 10G BaseT ports 1 x Management LAN port ASWM Enterprise Management Solution onboard ASMB8 iKVM for KVM over Internet Monitoring Operation temperature 10 C 35 C Environment Non operation temperature 40 C 70 C Non operation humidity 20 90 Non condensing Specifications are subject to change without notice Refer to www asus com for the complete list of supported PIKE cards Z10PE D16 Series specifications summary Model Name Z10PE D16 4L Z10PE D16 Intel C612 10 x SATA 6 Gbps ports or 9 x SATA 6 Gbps ports 1 x discrete M 2 connector Intel RSTe supports software RAID 0 1 5 and 10 Windows only Storage LSI MegaRAID supports software RAID 0 1 and 10 Linux and Windows Optional kits ASUS PIKE 3008 8 port SAS 12G RAID card ASUS PIKE 3108 8 port SAS 12G HW RAID card Graphic Aspeed AST2400 32 MB 1 x 24 pin SSI power connector 8 pin SSI 12V 8 pin SSI 12V 1 x USB 3 0 pin header up to 2 devices 1 x USB 2 0 pin header up to 2 devices Onboard I O x 4 pin headers Connectors Rear I O 2 x USB 2 0 Connectors 4 x GbE LAN ports 2 x GbE LAN ports 1 x Management LAN port 1 x Management LAN port SWM Enterprise Management Solution onboard ASMB8 iKVM for KVM over Internet Monitoring Operation temperature 10
30. Parity Enable Auto Allows you to enable or disable the DDR4 s command address parity Configuration options Auto Disabled Enabled Memory Topology Displays memory topology with DIMM population information Memory Thermal Allows you to configure thermal settings Set Throttling Mode Disabled Configuration options Disabled OLTT CLTT OLLT Peak BW xxx Allows you to set the peak allowed bandwidth for OLTT This is in percentage and valid offset values is from 25 100 DIMM Temp Stat xx Allows you to select DIMMTEMPSTAT as temp_mid or temp_hi Memory Power Savings Mode Auto Allows you to configure the CKE and other related Memory Power Savings features Configuration options Auto Disabled APD On User Defined Reserve Reserved Chapter 4 BIOS Setup Memory Power Savings Advanced Options CK in SR Auto Configuration options Auto Driven Tri State Pulled Low Pulled High MDLL Off Auto Allows you to shutdown MDLL during SR when enabled Configuration options Auto Disabled Enabled MEMHOT Throttling Mode Input only Allows you to shutdown MDLL during SR when enabled Configuration options Disabled Input only Output only Mem Electrical Throttling Disabled Allows you to configure Memory Electrical throttling Configuration options Disabled Enabled Auto Memory Map Channel Interleaving Auto Select different channel interleaving setting Configuration options Auto
31. Please restart your system C gt Z10PE D16 Series 4 6 4 2 BIOS setup program This motherboard supports a programmable firmware chip that you can update using the provided utility described in section 4 1 Managing and updating your BIOS Use the BIOS Setup program when you are installing a motherboard reconfiguring your system or prompted to Run Setup This section explains how to configure your system using this utility Even if you are not prompted to use the Setup program you can change the configuration of your computer in the future For example you can enable the security password feature or change the power management settings This requires you to reconfigure your system using the BIOS Setup program so that the computer can recognize these changes and record them in the CMOS RAM of the firmware chip The firmware chip on the motherboard stores the Setup utility When you start up the computer the system provides you with the opportunity to run this program Press lt Del gt during the Power On Self Test POST to enter the Setup utility otherwise POST continues with its test routines If you wish to enter Setup after POST restart the system by pressing lt Ctrl Alt Delete gt or by pressing the reset button on the system chassis You can also restart by turning the system off and then back on Do this last option only if the first two failed The Setup program is designed to make it as easy to use as po
32. Putty Keypad VT100 This allows you to select the FunctionKey and Keypad on Putty Configuration options VT 100 LINUX XTERMR6 SCO ESCN VT400 Redirection After BIOS POST Bootloader This setting allows you to specify if Bootloader is selected than Legacy console redirection Configuration options Always Enable Bootloader Serial Port for Out of Band Management Windows Emergency Management Services EMS Console Redirection Disabled Allows you to enable or disable the console redirection feature Configuration options Disabled Enabled 4 16 Chapter 4 BIOS Setup Z The following item appears only when you set Console Redirection to Enabled e Console Redirection Settings Out of Band Mgmt Port COM1 Microsoft Windows Emergency Management Services EMS allow for remote management of a Windows Server OS through a serial port Configuration options COM1 COM2 Terminal Type VT UTF8 Microsoft Windows Emergency Management Services EMS allow for remote management of a Windows Server OS through a serial port Configuration options VT100 VT100 VT UTF8 ANSI Bits per second 115200 Microsoft Windows Emergency Management Services EMS allow for remote management of a Windows Server OS through a serial port Configuration options 9600 19200 57600 115200 Flow Control None Microsoft Windows Emergency Management Services EMS allow for remote management of a Windows Serve
33. SATA5 SATA6 Light Blue SSATA1 SSATA2 SSATA3 Gray SSATA4 Light Gray M 2 NGFF connector NGFF1 USB 2 0 connector 10 1 pin USB56 USB 3 0 connector 20 1 pin USB3_34 CPU front and rear fan connectors 4 pin CPU_FAN1 CPU_FAN2 FRNT_FAN1 FRNT_FAN2 FRNT_FAN3 FRNT_FAN4 FRNT FAN5 REAR_FAN1 REAR_FAN2 Serial General Purpose Input Output connector 6 1 pin SGPIO1 SSGPIO1 10G LAN LED connector 5 1 pin LAN34_LED1 Power Supply SMBus connector 5 pin PSUSMB1 Serial port connector 10 1 pin COM1 Trusted Platform Module connector 20 1 pin TPM1 VGA connector 10 1 pin VGA_HDR1 ATX power connectors 24 pin EATXPWR1 8 pin EATX12V1 8 pin EATX12V2 4 pin EATX12V_NVDIMM1 System panel connector 20 1 pin PANEL1 Auxiliary panel connector 20 2 pin AUX_PANEL1 Hard disk activity LED connector 4 pin HDLED1 Chassis Intrusion 2 pin INTRUSION1 Z10PE D16 Series 2 3 Central Processing Unit CPU The motherboard comes with a surface mount LGA 2011 3 socket designed for the Intel Xeon E5 2600 v3 processor family e Upon purchase of the motherboard ensure that the PnP cap is on the socket and Ce the socket contacts are not bent Contact your retailer immediately if the PnP cap is missing or if you see any damage to the PnP cap socket contacts motherboard components ASUS will shoulder the cost of repair only if the damage is shipment transit related e Keep the cap after installing the
34. Supported by the Intel C612 series Chipset these connectors are for the Serial ATA signal cables for Serial ATA hard disk drives that allows up to 6 Gbps of data transfer rate If you installed Serial ATA hard disk drives you can use a software RAID solution to create a RAID 0 RAID 1 RAID 5 or a RAID 10 configuration For more information on the SATA RAID solutions supported on this motherboard refer to the RAID Configuration chapter of this user guide i a J l If 3 E z Ey ke Q Han m E Z10PE D16 Series SATA c nnectors SSATA1 f 5 installed 1 SATA1 GND RSATA_TXP1 RSATA_TXN1 GND RSATA_RXP1 RSATA_RXN1 GND 4 GN RSATA TXP RSATA TXN RSATA RXP RSATA RXN SATA5 GND RSATA TXP5 RSATA TXN5 GND RSATA RXP5 RSATA RXN5 GND SATA2 GND RSATA TXP2 RSATA TXN2 GND RSATA RXP2 RSATA RXN2 GND SATA3 6 GN RSATA_TXP RSATA TXN RSATA RXP RSATA RXN GN JwuwJwwUuU SATA GND RSATA TXP6 RSATA TXN6 GND RSATA RXP6 RSATA RXN6 GND SSATA1 GND RSATA_TXP1 RSATA_TXN1 GND RSATA_RXP1 RSATA_RXN
35. To delete a RAID set 1 From the utility main menu select 2 Delete RAID Volume and press lt Enter gt 2 From the Delete Volume Menu press the up down arrow keys to select the RAID set you want to delete then press Del Intel R Rapid Storage Technology enterprise SATA Option ROM 3 6 0 1023 Copyright C 2003 12 Intel Corporation All Rights Reserved Name Level Drives Capacit Status Bootable Volume0 RAIDO Stripe 2 298 0GB Normal Yes Deleting a volume will reset the disks to non RAID ALL DISK DATA WILL BE DELETED This does not apply to Recovery volumes t Select ESC Previous Menu DEL Delete Volume 3 Press lt Y gt to confirm deletion of the selected RAID set and return to the utility main menu or press lt N gt to return to the DELETE VOLUME menu This does not apply to Recovery volumes Are you sure you want to delete volume Volume0 Y N 5 28 Chapter 5 RAID Configuration 5 3 3 Resetting disks to Non RAID AN Take caution before you reset a RAID volume hard disk drive to non RAID Resetting a RAID volume hard disk drive deletes all internal RAID structure on the drive To reset a RAID set 3 From the utility main menu select 3 Reset Disks to Non RAID and press lt Enter gt Press the up down arrow keys to select the drive s or disks of the RAID set you want to reset then press lt Space gt A small triangle before the Port number marks the selected drive Pr
36. Updates the BIOS in DOS mode using a bootable USB flash disk drive Refer to the corresponding sections for details on these utilities NN Save a copy of the original motherboard BIOS file to a bootable USB flash disk drive in case you need to restore the BIOS in the future Copy the original motherboard BIOS using the BUPDATER utility 4 1 1 ASUS CrashFree BIOS 3 utility The ASUS CrashFree BIOS 3 is an auto recovery tool that allows you to restore the BIOS file when it fails or gets corrupted during the updating process You can update a corrupted BIOS file using a USB flash drive that contains the updated BIOS file aN Prepare a USB flash drive containing the updated motherboard BIOS before using this utility Recovering the BIOS from a USB flash drive To recover the BIOS from a USB flash drive 1 Insert the USB flash drive with the original or updated BIOS file to one USB port on the system Mo The utility will automatically recover the BIOS It resets the system when the BIOS recovery finished DO NOT shut down or reset the system while recovering the BIOS Doing so would cause system boot failure The recovered BIOS may not be the latest BIOS version for this motherboard Visit the ASUS website at www asus com to download the latest BIOS file Chapter 4 BIOS Setup 4 1 2 ASUS EZ Flash Utility The ASUS EZ Flash Utility feature allows you to update the BIOS without having to use a DOS based utility Befor
37. allows you to change the fan settings C 2013 American Megat CPU1 Temperature Z Scroll down to view the other items CPU1 2 Temperature xxx C xxx F The onboard hardware monitor automatically detects and displays the CPU temperatures CPU FAN1 2 Speed FRNT FAN1 5 Speed REAR FAN1 2 Speed xxxx RPM or N A The onboard hardware monitor automatically detects and displays the speed of CPU fans front fans and rear fan in rotations per minute RPM If the fan is not connected to the motherboard the field shows N A VCCIO VCORE1 2 Voltage VDDQ_AB_CPU1 Voltage VDDQ_CD_CPU1 Voltage VDDQ_EF_CPU2 Voltage VDDQ_GH_CPU2 Voltage 5VSB Voltage 5V Voltage 12V Voltage 3 3V Voltage VBAT Voltage 3 3VSB Voltage The onboard hardware monitor automatically detects the voltage output through the onboard voltage regulators CPU FAN1 amp 2 FRNT FAN1 mode Generic Mode Allows you to configure the ASUS Smart Fan feature that smartly adjusts the fan speeds for more efficient system operation Configuration options Generic Mode High Speed Mode Full Speed Mode Manual Mode Duty 50 This item appears only when CPU FAN1 amp 2 FRNT FAN1 mode is set to Manual Mode This item allows you to configure the fan duty setting from 10 to 100 FRNT FAN2 amp 3 4 amp 5 REAR FAN1 amp 2 mode Generic Mode Allows you to configure the ASUS Smart Fan feature that smartly adjusts the fan speeds for more efficient system oper
38. could serve as source for a driver disk Which would you like to use sdc sdd sr0 Chapter 6 Driver Installation 6 Insert the Red Hat Enterprise RAID driver disk to the USB floppy disk drive select OK then press Enter Insert Driver Disk Insert your driver disk into dev sdb and press OK to continue The drivers for the RAID card are installed to the system 7 When asked if you will load additional RAID controller drivers select No then press lt Enter gt More Driver Disks Do you wish to load any more driver disks 8 Follow the onscreen instructions to finish the OS installation Z10PE D16 Series 6 9 Preparing the Linux Driver Ensure that there is another computer with a Linux based OS to create the RAID driver When creating the RAID driver you may refer to the examples below which uses a 64bit SUSE Linux system to create a 64bit RAID driver for SUSE11 sp1 1 Copy the image file into the Linux system Example megasr 15 00 0120 2012 1 sles11 ga x86 64 img 2 Create a folder Example image 3 Mount the image file into the image folder using this command format mount oloop image file name image Example mount oloop megasr 15 15 00 0120 2012 1 sles11 ga x86 64 img image asus linux doeS tmp File Edit View Terminal Tabs Help asus linux doeS tmps su Password linux doe5 linux doe5 cd tmp linux doeS tmp mount o loop megasr 15 00 0120 2012 1
39. enabled LED SGPIO hardware is attached Configuration options Disabled Enabled Support Aggressive Link Power Management Enabled Allows you to enable or disable the Support Aggressive Link Power SALP Management Configuration options Disabled Enabled SATA Port 1 SATA Port 2 SATA Port 3 SATA Port 4 Port 1 Port 2 Port 3 Port 4 Allows you to enable or disable the SATA port Configuration options Disabled Enabled Z10PE D16 Series 4 33 4 34 PCH SATA Configuration SATA Controller Enabled Allows you to enable or disable the SATA Controller Configuration options Disabled Enabled Configure SATA as AHCI Allows you to identify the SATA port is connected to Solid State Drive or Hard Disk Drive Configuration options IDE AHCI RAID SATA Mode options SATA LED locate Enabled If enabled LED SGPIO hardware is attached Configuration options Disabled Enabled Support Aggressive Link Power Management Enabled Allows you to enable or disable the Support Aggressive Link Power SALP Management Configuration options Disabled Enabled SATA Port 1 6 Port 1 Port 2 Port 3 Port 4 Port 5 Port 6 Enabled Allows you to enable or disable the SATA port Configuration options Disabled Enabled USB Configuration XHCI Mode Auto Allows you to enable or disable the mode of operation of xHCI controller Configuration options Auto Disabled Enabled USB Ports Per Port Disable Control
40. f Intel Rapid Storage Technology enterprise System E mail Preferences Notify me by e mail of the following events Storage system information Storage system warnings Storage syster errors More help on this page Chapter 5 RAID Configuration Driver Installation This chapter provides the instructions for installing the necessary drivers for different system components in both Linux and Windows Operating Systems 6 1 RAID driver installation After creating the RAID sets for your server system you are now ready to install an operating system to the independent hard disk drive or bootable array This part provides the instructions on how to install the RAID controller drivers during OS installation 6 1 1 Creating a RAID driver disk Rn The system does not include a floppy drive You have to use a USB floppy drive when creating a SATA RAID driver disk If you have created RAID sets with the LSI Software RAID configuration utility the boot priority of the SATA optical disk drive has to be manually adjusted Otherwise the system will not boot from the connected SATA ODD To create a RAID driver disk in Windows environment 1 Start Windows 2 Place the motherboard support DVD into the optical drive 3 Go to the Make disk menu and then select the type of RAID driver disk you want to create 4 Insert a floppy disk into the USB floppy disk drive 5 Follow succeeding screen instructions to complete the
41. hard disk drives Among the advantages of RAID 5 configuration include better HDD performance fault tolerance and higher storage capacity The RAID 5 configuration is best suited for transaction processing relational database applications enterprise resource planning and other business systems Use a minimum of three identical hard disk drives for this setup e If you want to boot the system from a hard disk drive included in a created RAID set copy first the RAID driver from the support DVD to a floppy disk before you install an operating system to the selected hard disk drive e Please refer to chapter 2 for how to select the RAID configuration utility Move the jumper to choose between LSI MegaRAID and Intel Rapid RAID Chapter 5 RAID Configuration 5 1 2 Installing hard disk drives The motherboard supports Serial ATA for RAID set configuration For optimal performance install identical drives of the same model and capacity when creating a disk array To install the SATA hard disks for RAID configuration 1 Install the SATA hard disks into the drive bays following the instructions in the system user guide 2 Connect a SATA signal cable to the signal connector at the back of each drive and to the SATA connector on the motherboard 3 Connect a SATA power cable to the power connector on each drive 5 1 3 Setting the RAID item in BIOS You must set the RAID item in the BIOS Setup before you can create a RAID set from S
42. it is released from then gently lift the load lever F Z10PE D16 Series 4 Push the left load lever to slightly lift the load plate G j Ed f the Load plat aN Do not insert the load lever into the a al ta retention tab 5 Hold the edge then gently lift the load plate H Load plate 6 Getthe CPU Triangle mark 7 Align and position the CPU over the socket ensuring that the triangle mark on the CPU matches the triangle mark on the socket box 8 Install the CPU into the slot aN The CPU fits in only one correct orientation DO NOT force the CPU into the socket to prevent bending the CPU pins on the socket 9 Gently push the load plate just enough to let it sit on top of the CPU Do not force to close the load plate as it may damage the CPU 2 12 Chapter 2 Hardware Information 10 Push down the right load lever I ensuring that the edge of the load plate is fixed and tucked securely under the lever J then insert the right load lever under the retention tab K retention tab Keep the PnP cap ASUS will process Return Merchandise Authorization RMA requests Z The PnP cap pops out of the load plate when the right load lever is inserted into the N only if the motherboard comes with the PnP cap on the LGA 2011 3 socket PnP cap 11 Push down the left load lever L then insert it under the retention tab M pe Retention tab Z10PE D16 Series 2 13 12 Apply some Thermal
43. screen depends on the number of devices installed in the system Chapter 4 BIOS Setup VA e To select the boot device during system startup press lt F8 gt when ASUS Logo appears e To access Windows OS in Safe Mode please press lt F8 gt after POST Set the booting order of network devices Boot Option 1 2 SATA P2 ASUS Configuration options SATA P2 ASUS SATA P3 WDC WD80 AMI Virtual Floppy IBA GE Slot 0700 v CD DVD ROM Drive BBS Priorities Hard Drive BBS Priorities Network Device BBS Priorities These items appear only when you connect SATA ODD or hard drive to the SATA ports and allow you to set the booting order of the SATA devices 4 11 Tool menu The Tool menu items allow you to configure options for special functions Select an item then press lt Enter gt to display the submenu Aptio Setup Utility Copyright C 2013 American Megatrends Inc Start EzFlash ASUS EZ Flash Allows you to run ASUS EZ Flash BIOS ROM Utility when you press lt Enter gt Refer to the ASUS EZ Flash Utility section for details Z10PE D16 Series 4 48 4 12 Exit menu The Exit menu items allow you to save or discard your changes to the BIOS items Aptio Setup Utility Copyright C 2013 American Megatrends Inc Save Changes amp Exit V Pressing lt Esc gt does not immediately exit this menu Select one of the options from this menu or lt F10 gt from the legend
44. shared slots ensure that the drivers support Share IR or that the cards do not need IRQ assignments Otherwise conflicts may arise between the two PCI groups making the system unstable and the card inoperable 2 18 Chapter 2 Hardware Information 2 5 3 Interrupt assignments Standard Interrupt assignments IRQ Priority Standard function Programmable interrupt o Bo pe 15 3 SA 3 SystemCMOS RealTimeCloek o o o 6 IRQ Holder for PCI Steering oS a 9o o o ooo 6 C woo woo o 13 Numeric Data Processor ag Primary IDE Channel Secondary IDE Channel These IRQs are usually available for ISA or PCI devices 2 4 1 10 11 49 13 14 5 2 5 4 PCI Express x16 slot x16 link The onboard PCIE2 and PCIE4 provide two x16 Gen3 link to CPU2 the onboard PCIE6 provide one x16 Gens link to CPU1 These slots support VGA cards and various server class high performance add on cards 2 5 5 PCI Express x8 slot x8 link The onboard PCIE3 provides one x8 Gen3 link to CPU1 2 5 6 PCI Express x8 slot x4 link The onboard PCIE1 provides one x4 Gen link to CPU1 Z10PE D16 Series 2 19 Slot Short description location PCI E x8 x4 Gen3 link MIO supported PCI E x16 x16 Gen3 link PCI E x8 x8 Gens link PCI E x16 x16 Gen3 link PCI E x16 x16 Gen3 link aN The ASUS PIKE 3008 PIKE 3108 and PEM FDR cards must be installed on PCI E slot 2 3 4 6 2 20 Chapter 2 Hardware Informa
45. the available drives connected to the SATA ports Select the drive you want to rebuild and then press lt Space gt REBUILD PHYSICAL DRIVES SELECTION MENU Managen Configur See ONLIN A00 00 Objects Rebuild FAIL A00 01 Check Co Port 1 DISK 77247MB HDS72808PLA380 PF20A60A SPACE De Select F10 Start Rebuild F2 Drive Information F3 View Virtual Drives Chapter 5 RAID Configuration 3 After selecting the drive to rebuild press lt F10 gt When prompted press lt Y gt to rebuild the drive LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R Managen Configur Initiali A A ONLIN A00 00 Rebuilding of Drive Will Take A Few Minutes Start Rebuilding Drive Y N Port 1 DISK 77247MB HDS72808PLA380 PF20A60A SPACE De Select F10 Start Rebuild F2 Drive Information F3 View Virtual Drives 4 When rebuild is complete press any key to continue Z10PE D16 Series 5 17 5 18 5 2 5 Checking the drives for data consistency You can check and verify the accuracy of data redundancy in the selected virtual drive The utility can automatically detect and or detect and correct any differences in data redundancy depending on the selected option in the Objects gt Adapter menu N The Check Consistency command is available only for virtual drives included in a RAID 1 or RAID 10 set Using the Check Consistency Command To check data consistency using the Check Consistency
46. the proper orientation and push down firmly until the connectors completely fit DO NOT forget to connect the 24 pin and the 8 pin power plugs otherwise the system LN will not boot up unstable or may not boot up if the power is inadequate system Q EATX12V2 JHD IDH GN 12V DC DL GN noon beso l gg tr am WU om LI Z10PE D16 Series ATX power connectors 2 40 E 5V Standby 12 Volts 12 Volts 3 Volts gt This motherboard supports ATX2 0 PSU or later version The 4 pin EATX12V_NVDIMM1 is only required for NVDIMM Ensure that your PSU can provide at least the minimum power required by your Use of a power supply unit PSU with a higher power output is recommended when configuring a system with more power consuming devices The system may become TX12V1 EATX12V_NVDIMM1 GND 12V DC GND 12V DC PIN 1 Chapter 2 Hardware Information 13 System panel connector 20 1 pin PANEL1 This connector supports several chassis mounted functions PARE PAR EA h h
47. 011 1 0 compliant chassis Ensure to unplug the chassis power cord before installing or removing the motherboard Failure to do so can cause you physical injury and damage motherboard components 2 2 1 Placement direction When installing the motherboard ensure that you place it into the chassis in the correct orientation The edge with external ports goes to the rear part of the chassis as indicated in the image below 2 2 2 Screw holes Place ten 10 screws into the holes indicated by circles to secure the motherboard to the chassis DO NOT overtighten the screws Doing so can damage the motherboard Place this side towards the rear of the chassis Z10PE D16 Series 2 3 2 2 3 Motherboard layout Z10PE D16 2L 10G 2T VGA_HDR1 jun oo jun oo oo EPU E CPU_FAN2 DDR4 DIMM_G1 64bit 288 pin module DDR4 DIMM_G2 64bit 288 pin module DDR4 DIMM_H1 64bit 288 pin module Ih DDR4 DIMM_H2 64bit 288 pin module H MEMERRG1 MEMERRG2 MEMERRH1 N MEMERRH2 LGA2011 3 PSUSMB1 RO0N po ROO oan podo Jono OURO Ooo OOOO OOO EATX12V2 EATXPWR1 EATX12V1 FRNT_FAN2 FRNT_FAN1 DDR4 DIMM A1 64bit 288 pin module DDR4 DIMM A2 64bit 288 pin module DDR4 DIMM B1 64bit 288 pin module DDR4 DIMM B2 64bit 288 pin module A MEMERRA1 MEMERRA2 MEMERRB1 MEMERRB2 ERRCPU1 ERRCPU2 A
48. 1 GND SSATA4 GND RSATA_TXP4 RSATA_TXN4 GND RSATA_RXP4 RSATA_RXN4 GND SSATA2 GND RSATA_TXP2 RSATA_TXN2 GND RSATA_RXP2 RSATA_RXN2 GND SSATA3 GND RSATA_TXP3 RSATA_TXN3 GND RSATA_RXP3 RSATA_RXN3 GND The actual data transfer rate depends on the speed of Serial ATA hard disks The SSATA4 Light Gray will be automatically turned off if the M 2 connector NGFF is occupied 2 34 Chapter 2 Hardware Information 2 M 2 NGFF connector NGFF1 This connector allows you to install an M 2 device Gissseateiaes ssss saes at NGFF1 Hak Hi Z10PE D16 Series NGFF1 connector Rn This connector supports type 2242 devices on both PCI E and SATA interface Z The M 2 NGFF device is purchased separately 3 USB 2 0 connector 10 1 pin USB56 These connectors are for USB 2 0 ports Connect the USB module cables to connectors USB56 These USB connectors comply with USB 2 0 specification that supports up to 480 Mb s connection speed Cc BERRRERRHER BEA RGF
49. 2787 http support asus com techserv techserv aspx ASUS COMPUTER GmbH Germany and Austria Address Fax Web site Online contact Technical Support Telephone Support Fax Online support Harkort Str 21 23 D 40880 Ratingen Germany 49 2102 95991 1 http www asus de http www asus de sales 49 1805 010923 49 2102 959911 http support asus com techserv techserv aspx ASUS Czech Service s r o Europe Address Telephone Web site Technical Support Telephone Fax E mail Online Support Z10PE D16 Series Na Rovince 887 720 00 Ostrava Hrabova Czech Republic 420 596766888 http www asus cz 420 596 766 891 420 596 766 329 advance rma eu asus com http support asus com techserv techserv aspx A 7 A 8 ASUS contact information ASUS Holland BV The Netherlands Address Marconistraat 2 7825GD EMMEN The Netherlands Web site http www asus com Technical Support Telephone 31 0 591 5 70292 Fax 31 0 591 666853 E mail advance rma eu asus com Online Support http support asus com techserv techserv aspx ASUS Polska Sp z o o Poland Address UI Postepu 6 02 676 Warszawa Poland Web site http pl asus com Technical Support Telephone 48 225718033 Online Support http support asus com techserv techserv aspx ASK Service Russia and CIS Address r Mocksa yn OpaxoHukKuna3e 4 10 Poccua Telephone 495 640 32 75 Web site http ru asus com Technical Support T
50. 30 5 3 5 Rebuilding the BAID oi omega 5 30 5 3 6 Setting the Boot array in the BIOS Setup Utility 5 32 Intel Rapid Storage Technology enterprise Windows 5 33 5 4 1 Creating a RAID set sac ocnsnenscceniseaunceitdenenctansoniyeakastudceacigkarnednanons 5 34 5 4 2 Changing a Volume TYype oooooWoW oom mo Wa 5 36 5 4 3 Deleting a volume wo ocoWdocco o Wo1ksneonetakk amami alanan 5 37 5 4 4 Preferenge aa bia kalangan ietaonia 5 38 Chapter 6 Driver Installation 6 1 RAID driver installation Jo 6 1 1 Creating a RAID driver disk oooooWo Wcom 6 1 2 Installing the RAID controller driver ooooooWom 6 2 Management applications and utilities installation 6 3 Running the Support DVD oom mna 6 4 Intel chipset device software installation ooooooo 6 5 Installing the Intel 1350 AM1 1350 AM2 1210 X540 BT2 Gigabit Adapters QHIVG Meccan mam aan 6 6 VGA driver installation oooooo oo oom 6 7 Intel Rapid Storage Technology enterprise 4 0 installation Appendix Z10PE D16 Series block diagram ASUS contact information vii viii Notices Federal Communications Commission Statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions e This device may not cause harmful interference and e This device must accept any interference received including interferen
51. ATA hard disk drives attached to the SATA connectors supported by Intel C612 chipset To do this 1 Enter the BIOS Setup during POST 2 Go to the Advanced Menu gt PCH SATA Configuration then press lt Enter gt 3 Set SATA Mode to RAID Mode 4 Press lt F10 gt to save your changes and exit the BIOS Setup RR Refer to Chapter 4 for details on entering and navigating through the BIOS Setup 5 1 4 RAID configuration utilities Depending on the RAID connectors that you use you can create a RAID set using the utilities embedded in each RAID controller For example use the LSI MegaRAID Software Configuration Utility or the Intel Rapid Storage Technology if you installed Serial ATA hard disk drives on the Serial ATA connectors supported by the Intel C612 chipset Refer to the succeeding section for details on how to use the RAID configuration utility Z10PE D16 Series 5 3 5 4 5 2 LSI Software RAID Configuration Utility The LSI MegaRAID software RAID configuration utility allows you to create RAID 0 RAID 1 or RAID 10 set s from SATA hard disk drives connected to the SATA connectors supported by the motherboard southbridge chip To enter the LSI MegaRAID software RAID configuration utility 1 Turn on the system after installing all the SATA hard disk drives 2 During POST the LSI MegaRAID software RAID configuration utility automatically detects the installed SATA hard disk drives and displays any existing RAID set
52. C 35 C Environment Non operation temperature 40 C 70 C Non operation humidity 20 90 Non condensing Specifications are subject to change without notice Refer to www asus com for the complete list of supported PIKE cards xvi Product Introduction This chapter describes the motherboard features and the new technologies it supports 1 1 Welcome Congratulations and thank you for buying an ASUS Z10PE D16 Series motherboard The motherboard delivers a host of new features and latest technologies making it another standout in the long line of ASUS guality motherboards Before you start installing the motherboard and hardware devices on it check the items in your package with the list below 1 2 Package contents Check your motherboard package for the following items en Standard Gift Box Pack Standard ai Pack VO Shield naa BMN SATAEGCabIo 0110 O east Application CD ememason 1 1 piece per carton AsmBsikumsovo 1 1 piece per carton Packaging Quantity BE 1 piece percarton 10 pieces per carton If any of the above items is damaged or missing contact your retailer Y Optional items Description PIKE3008 ILSI8 port SAS 12G RAID card its PIKE 3108 LSI 8 port SAS 12G HW RAID card PEM FDR Mellanox ConnectX 3 FDR card aN The ASUS PIKE 3008 PIKE 3108 and PEM FDR cards must be installed on PCIE slot 2 3 4 6 Chapter 1 Product Introduct
53. Configuration options Disabled Enabled Intel LAN ROM Type PXE Allows you to select the Intel LAN ROM type Configuration options PXE iSCSI Intel LAN 1350 LAN1 LAN2 Enable Enabled Allows you to enable or disable the Intel LAN Configuration options Disabled Enabled Z The following items appear only when Intel LAN 1350 LAN1 LAN2 Enable is set to Enabled LAN1 LAN2 Option ROM Support Enabled Allows you to load the Intel LAN ROM Configuration options Disabled Enabled Intel LAN 1350 LAN3 LAN4 Enable Enabled Z10PE D16 2L 10G 2T and Z10PE D16 4L Allows you to enable or disable the Intel LAN Configuration options Disabled Enabled Z The following items appear only when Intel LAN 1350 LAN3 LAN4 Enable is set to Enabled LAN3 LAN4 Option ROM Support Enabled Allows you to load the Intel LAN ROM Configuration options Disabled Enabled Z10PE D16 Series 4 13 4 45 Onboard LAN X540 IO Configuration Z10PE D16 2L 10G 2T and Z10PE D16 10G 2T This allows you to change the enable or disable the onboard LAN Aptio Setup Utility Copyright C 2013 American Megatrends Inc Intel LAN Support Intel LAN Support Enabled Allows you to enable or disable the Intel LAN Configuration options Disabled Enabled Intel LAN ROM Type PXE Allows you to select the Intel LAN ROM type Configuration options PXE iSCSI Intel LAN X540 LAN3 Intel LAN X540 LAN4 Enable Enabled
54. Core Logic Form Factor ASUS Features Expansion Slots follow SSI Location number Networking Z10PE D16 4L Z10PE D16 2 x Socket R3 2011 Intel Xeon processor E5 2600 V3 product family QPI 6 4 8 0 9 6 GTps Intel C612 PCH SSI EEB 12 in x 13 in 16 4 channels per CPU 2 DIMMs per CPU Maximum up to 1024 GB DDR4 2133 1866 1600 1333 RDIMM LR DIMM NVDIMM Refer to www asus com for latest memory AVI updates 4 GB 8 GB 16 GB 32 GB RDIMM 32 GB 64 GB LR DIMM 1 x PCI E x8 x4 Gen3 link MIO supported 1 x Dual port Intel 1350 AM2 Gigabit LAN controller 1 x Dual port Intel 1350 AM2 1 x Dual port Intel I350 BT2 Gigabit LAN controller Gigabit LAN controller 1 x Management port 1 x Management port continued on the next page Specifications are subject to change without notice Z10PE D16 Series specifications summary Model Name Z10PE D16 2L 10G 2T Z10PE D16 10G 2T Intel C612 10 x SATA 6 Gbps ports or 9 x SATA 6 Gbps ports 1 x discrete M 2 connector Intel RSTe supports software RAID 0 1 5 and 10 Windows only Storage LSI MegaRAID supports software RAID 0 1 and 10 Linux and Windows Optional kits ASUS PIKE 3008 8 port SAS 12G RAID card ASUS PIKE 3108 8 port SAS 12G HW RAID card Graphic Aspeed AST2400 32 MB 1 x 24 pin SSI power connector 8 pin SSI 12V 8 pin SSI 12V 1 x USB 3 0 pin header up to 2 devices 1 x USB 2 0 pin header up to 2 devices
55. D EATX12V2 EATX12v1 EATXPWR1 O 0000 se DDR4 DIMM_G1 64bit 288 pin module Oj OOOO Tunet KB_USB78 EAN REP DDR4 DIMM_G2 64bit 288 pin module DDR4 DIMM_H1 64bit 288 pin module th DDR4 DIMM_A1 64bit 288 pin module DDR4 DIMM_H2 64bit 288 pin module H DDR4 DIMM_A2 64bit 288 pin module ES DDR4 DIMM_B1 64bit 288 pin module MEMERRH1 MEMERRH2 DDR4 DIMM_B2 64bit 288 pin module MEMERRA1 MEMERRA2 MEMERRB1 MEMERRB2 FRNT_FAN2 FRNT_FAN1 ar q R VGA_HDR1 p ijone LGA2011 3 ERRCPU1 LGA2011 3 ERRCPU2 II REAR_FAN1 REAR_FAN2 DDR4 DIMM_F2 64bit 288 pin module kK MEMERRD27 cpy FAN1 MEMERRD1 DDR4 DIMM F1 64bit 288 pin module MEMERRC2 MEMERRC1 DDR4 DIMM_D2 64bit 288 pin module el o ks a n 2 Z lt i Q DDR4 DIMM_E2 64bit 288 pin module MEMERRF2 MEMERRF1 MEMERRE2 MEMERRE1 A Intel 1350 BT2 LAN_SW1 EET BELI LAN SW2 g inal PCIE4 Lithium Cell PCIE3 CMOS Power E DDR4 DIMM_E1 64bit 288 pin module DDR4 DIMM_D1 64bit 288 pin module Hl PCIE6 DDR4 DIMM_C2 64bit 288 pin module f DDR4 DIMM_C1 64bit 288 pin module FRNT_FAN3 Q EATX12V_NVDIMM1 me ASUS Z10PE D16 4L COMI EEE vea sw1 P5VLED1 CIBMCLED1 PCIE2 ILCMX0256C CLRTC1 RAID_SEL1 HDLED1 TPM1 R1 DOM1_PWAI EEE ARAHARRHA LAN34_LED1 AUX_PANEL1 lelelelelelalel SMBUS1 RAID KEY1 SGPIOIEELEEE
56. Data Rate 4 DDR4 Dual Inline Memory Modules DIMM sockets The figure illustrates the location of the DDR4 DIMM sockets DIMM G1 ERA RA a i DIMM_G2 x i DIMM_H1 DIMM_H2 DIMM_A1 DIMM_A2 DIMM_B1 DIMM_B2 DIMM_F2 DIMM_F1 DIMM_E2 DIMM_E1 DIMM D2 DIMM_D1 DIMM_C2 E DIMM_C1 J F om OL Z10PE D16 Series 288 pin DDR4 DIMM sockets 2 4 2 Memory Configurations You may install 4 GB 8 GB 16 GB and 32 GB RDIMMs or 32 GB 64 GB LR DIMMs and NVDIMM into the DIMM sockets using the memory configurations in this section Rn Refer to ASUS Server AVL for the updated list of compatible DIMMs e When installing only one DIMM in a single CPU configuration install the DIMM on either A1 or B1 e Always install DIMMs with the same CAS latency For optimum compatibility it is recommended that you obtain memory modules from the same vendor Z10PE D16 Series Single CPU configuration You can refer to the following recommended memory population for a sing
57. Disabled Allows you to control each of the USB ports 1 to 8 disabling Configuration options Disabled Enabled Z The following items appears only when the USB Ports Per Port Disable Control is set to Enabled USB Port 1 2 3 4 5 6 7 8 Enabled Configuration options Disabled Enabled USB 3 0 Port 1 2 3 4 Enabled Configuration options Disabled Enabled Chapter 4 BIOS Setup Platform Thermal Configuration PCH Thermal Device Auto Allows you to enable or disable the PCH Thermal Device D31 F6 Configuration options Auto Disabled Enabled Alert Enable Lock Disabled Allows you to lock all Alert Enable settings Configuration options Disabled Enabled 4 5 8 Miscellaneous Configuration Active Video Offboard Device Allows you to select the video type Configuration options Onboard Device Offboard Device 4 5 9 Server ME Configuration Displays the Server ME Technology parameters on your system Aptio Setup Utility Copyright C 2013 American Megatrends Inc 4 5 10 Runtime Error Logging Support Runtime Error Logging Whea Support Disabled This item allows you to enable or disable the WHEA support Configuration options Disabled Enabled Z10PE D16 Series 4 35 4 36 4 6 Server Mgmt menu The Server Management menu displays the server management status and allows you to change the settings Aptio Setup Utility Copyright C 2013 American M
58. ED OF THE POSSIBILITY OF SUCH DAMAGES ARISING FROM ANY DEFECT OR ERROR IN THIS MANUAL OR PRODUCT SPECIFICATIONS AND INFORMATION CONTAINED IN THIS MANUAL ARE FURNISHED FOR INFORMATIONAL USE ONLY AND ARE SUBJECT TO CHANGE AT ANY TIME WITHOUT NOTICE AND SHOULD NOT BE CONSTRUED AS A COMMITMENT BY ASUS ASUS ASSUMES NO RESPONSIBILITY OR LIABILITY FOR ANY ERRORS OR INACCURACIES THAT MAY APPEAR IN THIS MANUAL INCLUDING THE PRODUCTS AND SOFTWARE DESCRIBED IN IT Products and corporate names appearing in this manual may or may not be registered trademarks or copyrights of their respective companies and are used only for identification or explanation and to the owners benefit without intent to infringe Contents NOCES an an E an ap viii Federal Communications Commission Statement ooooooo viii Canadian Department of Communications Statement oooo viii REACER BN an E AA viii Safety information ss sssssssssuseunsunsnunnnnnnunnunnnnnnunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn SN KR TANDA Ui ix Electrical Sate ena Aa an eure ten Ix PET ALON Sae tease act tise td seed stands andere rn una ix Australia statementinOtige co oco ocooo o mw mon ka na anlar aided teas X How this Quide is Organized e ma e en ema ana Xi Where to find more information ooooWoooWooWoWmaaa Xi Z10PE D16 Series specifications SUMMary ooooo oom xiii Chapter 1 Product Introduction 1 1 Welcome aa aan 1 2 1 2 PAC
59. Enabled Enable Hibernation Enabled Allows you to enable or disable the ability of the system to hibernate OS Sleep State Configuration options Disabled Enabled Rn This option may be not effective with some OS 4 4 2 Smart Settings Aptio Setup Utility Copyright C 2013 American Megatrends Inc SMART Self Test SMART Self Test Disabled Allows you to run SMART Self Test on all HDDs during POST Configuration options Disabled Enabled Z10PE D16 Series 4 11 4 12 4 4 3 NCT6779D Super IO Configuration Aptio Setup Utility Copyright C 2013 American Megatrends Inc b Serial Port 1 Configuration Serial Port 1 Serial Port 2 Configuration Allows you to set the parameters of Serial Port 1 Serial Port 2 Serial Port Enabled Allows you to enable or disable Serial Port Configuration options Disabled Enabled Change Settings Auto Allows you to choose the setting for Super IO device Configuration options Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 lO 2F 8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 lO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Chapter 4 BIOS Setup 4 4 4 Onboard LAN 1350 IO Configuration Z10PE D16 2L 10G 2T Z10PE D16 4L and Z10PE D16 Aptio Setup Utility Copyright C 2013 American Megatrends Inc Intel LAN Support Intel LAN Support Enabled Allows you to enable or disable the Intel LAN
60. IOS setup to re enter data DO NOT remove the cap on CLRTC jumper default position except when clearing the RTC RAM Removing the cap will cause system boot failure If the steps above do not help remove the onboard battery and move the jumper again to clear the CMOS RTC RAM data After the CMOS clearance reinstall the battery KAA EA TTF CLRTC1 12 2 3 Normal Clear RTC Ben Default Z10PE D16 Series Clear RTC RAM Z10PE D16 Series 2 27 VGA controller setting 3 pin VGA SWI1 This jumper allows you to enable or disable the onboard VGA controller Set to pins 1 2 to activate the VGA feature vwvw Ka aa h VGA SWI1 2 3 E ho
61. Interface Material to the exposed area of the CPU that the heatsink will be in contact with e Ensure that the Thermal Interface Material is spread in an even thin layer e Some heatsinks come with pre applied Thermal Interface Material If so skip this step The Thermal Interface Material is toxic and inedible DO NOT eat it If it gets into your eyes or touches your skin wash it off immediately and seek professional medical help 13 Connect the CPU fan cable to the connector on the motherboard labeled CPU_FAN1 CPU_FAN2 CPU_FAN2 CPU_FAN1 PWM A err S FAN Speed FAN Power GND ra i PA Cc RAR REP BARA F N OF ne 2350 To Hi JE a ga 1 o lc S O TF T om aay Blan U F MM min Z10PE D16 Series CPU fan connectors DO NOT forget to connect the CPU fan connector Hardware monitoring errors can occur if you fail to plug this connector 2 14 Chapter 2 Hardware Information 2 4 System memory 2 4 1 Overview The motherboard comes with sixteen 16 Double
62. KAGE contents Mama ata akn aa ana 1 2 13 Serial number label ba ama mama 1 3 1 4 Special feature Sa in Bona Aan 1 3 1 4 1 Produc Monge cecs NN BEN 1 3 1 4 2 Innovative ASUS features 1 4 Chapter 2 Hardware Information 2 1 Before you process ab anakan 2 2 2 2 Motherboard Overview oom 2 3 221 Placement direction Jenita mama 2 3 2 2 2 p16 A 016 2 ena nee ee ee ee eee 2 3 2 2 3 Motherboard layOUt nenian eaa 2 4 2 2 4 Layout Contest AR 2 8 2 3 Central Processing Unit CPU oooooo oom 2 10 2 3 1 Instal ling the CPU amaasanana 2 10 2 4 System MEMONY sncicceceisescctcnscssnncensossasteecesiasessctsndcesssctansnessessntextescstsesanntents 2 15 2 4 1 OVENVIEW bete ab aan dite ucusvigns maa E E 2 15 2 4 2 Memory GonfiguratiOnS5 Low omocoooomooomobdnt 2 15 2 4 3 Installing a DIMM on a single clip DIMM socket 2 17 2 5 Expansion SIOt Sa aa anik 2 18 2 5 1 Installing an expansion CATd oooooWooWooW WWW Wo 2 18 2 5 2 Configuring an expansion card oooo Woo 2 18 2 5 8 Interruptassign MENIS Laoneis an ana 2 19 2 5 4 PCI Express x16 slot X16 link ooooWoooWoo 2 19 25 5 PCI Express x8 slot x8 link oooWooWoWooW XX 2 19 2 5 6 PCI Express x8 slot X4 link ooooooo Wo Woo 2 19 Contents 2 6 2 1 2 8 Onboard LEDS ea 2 21 JUMPEN ie aki 2 27 CONNECIOLS aa 2 32 2 8 1 Rear panel connectorS ooooo Woo WW JW 2 32 2 8 2 Internal CONNECHOMS
63. L 9LG 3dOLZ 1p 9Ld 3dOLZ 9LG 3dOLZ J9gwnN japow paerogadujoy WeN JonpOd jonpoad y yey saxejoop Aqa SSS BONOTIS LLLE 6 L 01S ON Xeq ou0yd 6 Sp6 VI Tuowday Aem ajedodI0 008 SSdAPPV Ieuoyeuannjuy Jognd wo snsy Duren Aed a qQIsUOdsay LLOI T WORSE Z Wed ODA Jed ALINUYUOANOD AO NOLLVAV Dada A 9 Z10PE D16 Series A 10 Appendix
64. N Power GND RNT_FAN3 FRNT FAN4 PWM Control FAN Speed FAN Power GND f PWM Control FAN Speed FAN Power GND CPU FAN2 PWM Control FAN Speed FAN Power GND REAR FAN2 H PWM Control FAN Speed FAN Power GND FRNT FAN5 PWM Control FAN Speed FAN Power GND Chapter 2 Hardware Information 6 Serial General Purpose Input Output connector 6 1 pin SGPIO1 SSGPIO1 The SGPIO1 SSGPIO1 connectors are used for the Intel Rapid Storage Technology Enterprise SGPIO interface that controls the LED pattern generation device information and general purpose data SGPIO1 is the jumper for SATA1 6 while SSGPIO1 is the jumper for SSATA1 4 SGPIO SDATAOUT1 SGPIO_SCLK SGPIO_SDATAOUTO SGPIO_SLOAD GND com A BP Hon A PIN1 Z10PE D16 Series SGPIO connector 7 10G LAN LED connector 5 1 pin LAN34 LED1 These leads are for 10G LAN activity LEDs on the front panel Connect the LAN LED cable to the backplane for LAN activity indication
65. N2_LINKACTLED These connectors are for Gigabit LAN activity LEDs on the front panel Locator LED 2 pin LOCATORLED1 LOCATORLED2 These connectors are for the locator LED1 and LED2 o n the front panel Connect the Locator LED cables to these 2 pin connector The LEDs will light up when the Locator button is pressed Locator Button Switch 2 pin LOCATORBTN These connectors are for the locator button on the front the state of the system locator panel This button queries Chapter 2 Hardware Information 15 Hard disk activity LED connector 4 pin HDLED1 This LED connector is for the storage add on card cable connected to the SATA or SAS add on card The read or write activities of any device connected to the SATA or SAS add on card causes the front panel LED to light up K E UB o D AB 3 f1 5 AA g Gi oo 5 TT f al 00 S m Z Z ee a P 1 O a0 O oO ono L Cl Z4 lt 4 zZz i bong E E i 3 Pas i B HDLED1 ooo Z10PE D16 Series Hard disk activity LED connector 16 Chassis Intrusion 2 pin INTRUSION1 These l
66. Navigate Between Items And Press Enter To Select An Option 5 Follow step 10 to 14 of the previous section Using Easy Configuration to create the RAID set 5 10 Chapter 5 RAID Configuration 5 2 2 Adding or viewing a RAID configuration You can add a new RAID configuration or view an existing configuration using the View Add Configuration command Adding a new RAID configuration To add a new RAID configuration 1 From the Management Menu select Configure gt View Add Configuration and then press lt Enter gt Configuration Menu Easy Configuration Configure fiview Add Configuration Initialize Clear Configuration Objects Select Boot Drive Rebuild Check Consistency View Add to The Existing Configuration Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2 The ARRAY SELECTION MENU displays the available drives connected to the SATA ports Select the drive s you want to include in the RAID set then press lt Space gt When selected the drive indicator changes from READY to ONLIN A X Y where X is the array number and Y is the drive number View Add Configuration ARRAY SELECTION MENU Initiali Objects Rebuild ONLIN A00 01 READY ONLIN A00 00 Port 2 DISK 77247MB HDS72808PLA380 PF20A60A SPACE Sel ENTER EndArray F10 Configure F2 Drive Info F3 Virtual Drives F4 HSP aN The information of the selected hard disk drive di
67. Pa EGE IN SEARCH OF INCREDIBLE Z10PE D16 Series mi 4 vl once 001 EN et 01000011100000010 N 00010000 eni Dogs 100000010 TA 50101010100 o00110101bo 1010 10008 oo anit 1000000101001010106 STOTT a angga vs JO 4 E10401 Revised Edition V2 May 2015 Copyright O 2015 ASUSTeK COMPUTER INC All Rights Reserved No part of this manual including the products and software described in it may be reproduced transmitted transcribed stored in a retrieval system or translated into any language in any form or by any means except documentation kept by the purchaser for backup purposes without the express written permission of ASUSTeK COMPUTER INC ASUS Product warranty or service will not be extended if 1 the product is repaired modified or altered unless such repair modification of alteration is authorized in writing by ASUS or 2 the serial number of the product is defaced or missing ASUS PROVIDES THIS MANUAL AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT SHALL ASUS ITS DIRECTORS OFFICERS EMPLOYEES OR AGENTS BE LIABLE FOR ANY INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING DAMAGES FOR LOSS OF PROFITS LOSS OF BUSINESS LOSS OF USE OR DATA INTERRUPTION OF BUSINESS AND THE LIKE EVEN IF ASUS HAS BEEN ADVIS
68. R Network Connections SNMP Agent Feature Description 6 20 Chapter 6 Driver Installation 9 Click Install to start the installation Ready to Install the Program The wizard is ready to begin installation intel Click Install to begin the installation If you want to review or change any of your installation settings dick Back Click Cancel to exit the wizard 10 When the installation is done press Finish to complete the installation Install wizard Completed To access new features open Device Manager and view the properties of the network adapters Z10PE D16 Series 6 21 6 6 VGA driver installation This section provides the instructions on how to install the ASPEED Video Graphics Adapter VGA driver You need to manually install the ASPEED VGA driver on a Windows operating system To install the ASPEED VGA driver 1 Restart the computer and then log on with Administrator privileges 2 Insert the motherboard system support DVD to the optical drive The support DVD automatically displays the Drivers menu if Autorun is enabled in your computer If Autorun is NOT enabled in your computer browse the contents of the support DVD to locate the file ASSETUP EXE from the BIN folder Double click the ASSETUP EXE to run the support DVD 3 Click the ASPEED AST2300 AST2400 Display Driver to begin installation ASUS Install Drivers Installation Wizard Install ASPEED AST2300
69. SE Security Phase Normal boot PEI Pre EFI initialization phase Z10PE D16 Series DESCRIPTION irst post code POWER ON POST CODE oad BSP microcode MICROCODE POST CODE et cache as ram for PEI phase CACHE ENABLED POST CODE PU Early init CPU EARLY INIT POST CODE initializes South bridge for PEI preparation TI ress ep ress NB initialize before installed memo B initialize before installed memory Wait BMC ready duration 120 seconds QPI initialization QPI initialization QPI initialization QPI initialization QPI initialization OPI initialization QPI initialization QPI initialization QPI initialization QPI initialization QPI initialization Complete Init ress oo co oW BO WwW wiw uo NO Al 15 1519 ojojo dp 2 o O is m vp p z zz zz zzz zzz zz zz zz sz z sz sz zzz e olo o lo lo DDDDD DD DDD DDD 52 5 DV DDD D DD DdDDIDDDD 2 2 2292o Iss oo eko e Ololoololilllolo alala e aa aalala ooo e e e e ko ko a a Oo ml P D l9 P P pjp bip bip bis P a aa a ap p ago Is PD DDD n w nn O lo lo lo lo lo lo lo lo lo lo lo lo lo lo O lo lo lo lo lo lo lo lo lo lo nw nn Wn n eceeeerceeceeceecerse lt eeeeeeereee I P i Do OD Dl OD lo D0 D0 lo 0 i DIN NIN IK IK Iw Iw ND NIN Iw Iw WW n Im NINN NIN Iw Iw WW NIN NIN IU Iw Iw Iw IwY NIN Iw Iw WW n Im NIN ND NIN Iw Iw WW ogress Init KR oo Init N Init co gt Init Init Done ogress Other config After RC end ress
70. Tu ASPEED Laka COM1 EEE sios na VGA_SW1 AST2400 HN eee nono PCIE2 CATTERRI TPM1 P5VLED1 Super PA Ong pom pwr Ete lelei iaueree VO HDLED1 LAN34_LED1 BARBRHERE LED1 SMBUS1 RAID KEY1 AUX_PANEL1 E T SGPIO1EELEEE EEE usB3_34_PANEL1 FAMARABEFA SSGPIO1EELEEE CI NGFF1 ELE CEE Ore a SBPWR1 CPLD_JTAG1 ME RCVR1 SMART PSU1 FRNT FAN4 PCH MFG1 DIMMTRIP1 FRNT FANS MIC EN1 INTRUSION1 Z10PE D16 Series 2 2 4 Layout contents Slots Sockets Page 1 CPU sockets 2 DDR4 sockets 3 PCI Express x16 PCI Express x8 Onboard LEDs 1 Standby Power LED SBPWR1 2 Baseboard Management Controller LED BMCLED1 3 CPU Warning LED ERRCPU1 ERRCPU2 4 Power LED P5VLED1 5 Location LED LOCLED2 6 DIMM warning LED MEMERRA1 MEMERRA2 MEMERRB1 MEMERRB2 MEMERRC1 MEMERRC2 MEMERRD1 MEMERRD2 MEMERRE1 MEMERRE2 MEMERRF1 MEMERRF2 MEMERRGI MEMERRG2 MEMERRH1 MEMERRH2 7 CATT LED CATTERRI1 8 Q Code LEDs Jumpers 1 Clear RTC RAM CLRTC1 2 VGA controller setting 3 pin VGA_SW1 3 LAN controller setting 3 pin LAN_SW1 LAN SW2 LAN SW3 LAN SW4 4 PMBus 1 2 PSU select jumper 3 pin SMART PSU1 5 ME firmware force recovery setting 3 pin ME RCVR1 6 DDR4 thermal event setting 3 pin DIMMTRIP1 7 RAID configuration utility selection 3 pin RAID SEL1 8 BMC Setting 3 pin BMC ENI1 2 8 Chapter 2 Hardware Information Internal connectors Serial ATA 6 0 Gbps connectors 7 pin SATA1 SATA2 SATA3 SATA4
71. Xx GND IntA P1 SSTX GND IntA P1 Dx IntA P1 D Vbus ID PIN1 USB3 34 m IntA P1 SSTX 4 GND GND IntA P2 D Vbus IntA P2 SSRX IntA P2 SSRXx IntA P2 SSTX IntA P2 SSTX4 IntA P2 D Z10PE D16 Series USB 3 0 connector CPU front and rear fan connectors 4 pin CPU FAN1 CPU FAN2 FRNT FANI1 FRNT FAN2 FRNT FAN3 FRNT FAN4 FRNT FAN5 REAR_FAN1 REAR FAN2 The fan connectors support cooling fans Connect the fan cables to the fan connectors on the motherboard ensuring that the black wire of each cable matches the ground pin of the connector DO NOT forget to connect the fan cables to the fan connectors Insufficient air flow inside the system may damage the motherboard components e These are not jumpers DO NOT place jumper caps on the fan connectors e All fans feature the ASUS Smart Fan technology o SS _ Dar fico B aon A NAMA Z10PE D16 Series FA N connectors FRNT FAN1 FRNT FAN2 PWM Control PWM Control FAN Speed FAN Speed FAN Power FAN Power GND GND OREAR FAN1 CPU FAN1 H H PWM Control FAN Speed FAN Power GND PWM Control FAN Speed FA
72. able or disable the AES NI support Configuration options Disabled Enabled Down Stream PECI Disabled This Item allows you to enable the PCle Down Stream PECI writer Configuration options Disabled Enabled Z10PE D16 Series 4 27 4 5 2 Advanced Power Management Configuration Power Technology Energy Efficient This item allows you to enable power management features Configuration options Disabled Energy Efficient Custom Config TDP Disabled This item allows you to enable disable the Config TDP Configuration options Disabled Enabled CPU Advanced PM Turning Energy Perf BIAS Power Performance switch Enabled Allows you to switch between Power or performance Configuration options Disabled Enabled Workload Configuration Balanced Optimization for the workload characterization Configuration options Balanced I O sensitive Workload Configuration 23 This is used to control the effective window of the average for CO and PO time PO TotalTimeThreshold Low 35 The HW switching mechanism disables the performance setting 0 when the total PO time is less than this threshold PO TotalTimeThreshold High 58 The HW switching mechanism enables the performance setting 0 when the total PO time is greater than this threshold 4 5 3 Common RefCode Configuration Numa Enabled This item enables or disables the Non uniform Memory Access NUMA Configuration options Disabled Enabled Cha
73. agement with the features of Energy Efficient Turbo Uncore Frequency Scaling and Per Core P state Also the Integrated Voltage Regulator enables generational performance and power improvements that the standard VR solutions cannot provide DDR4 memory support The motherboard supports DDR4 memory that features faster clock frequencies and higher data transfer rates of 1333 MT s to 2133 MT s million transfers per second DDR4 offers a lower voltage standard of 1 2V that reduces memory power demand and provides improved performance Z10PE D16 Series 1 3 PCI Express 3 0 PCI Express 3 0 PCle 3 0 is the PCI Express bus standard that provides twice the performance and speed of PCle 2 0 It provides an optimal graphics performance unprecedented data speed and seamless transition with its complete backward compatibility to PCle 2 0 devices Intel C612 Series Chipset The Intel C612 series chipset supports with enterprise class features which is targeted for Cloud and Storage applications It is optimized and validated to work with the latest Xeon processor E5 2600 v3 product family compared with the last generation it also reduces the TDP supports USB 3 0 and up to 10 SATA III ports thus bringing more features and benefits to the target users Intel X540BT2 10GbE LAN controller Supported Models Z10PE D16 2L 10G 2T amp Z10PE D16 10G 2T The Intel 10 Gigabit Ethernet controller X540 is a dual port 10GBASE T network interfa
74. al Drive select an existing adapter and press Enter Select View Update Parameters and press Enter to display the adapter properties Z10PE D16 Series 5 23 4 Select Disk WC and then press lt Enter gt to turn on the option LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R 0b t RAID ects i Management ad ee ae i ap Stripe Size Configure i i Ha Stripss Initialize physical Driv State aeons earn Check Consistency 2 oan 8 580GB bb an w PTIMAL OWL OMNN 2 make 3 Disk Write Cache Setting of VD Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 5 When finished press any key to continue 5 24 Chapter 5 RAID Configuration 5 3 Intel Rapid Storage Technology enterprise SATA SSATA Option ROM Utility The Intel Rapid Storage Technology enterprise SATA SSATA Option ROM utility allows you to create RAID 0 RAID 1 RAID 10 RAID 1 0 and RAID 5 set from Serial ATA hard disk drives that are connected to the Serial ATA connectors supported by the Southbridge aN Before you proceed ensure that you have installed the Serial ATA hard disk drives have set the correct jumper settings of the motherboard and have set the correct SATA mode in the BIOS setup You can refer to the Installing hard disk drives Setting Jumpers and Setting the RAID mode sections in BIOS for more information To launch the Intel Rapid Storage T
75. appears including a Virtual Drive menu that allows you to change the virtual drive parameters Manage Initial Objects Rebuild Check C Virtual Drive s Configured RAID Size Stripes Strips Status 1 148 580GB 2 64KB ONLINE Virtual Drive 0 Units MB Size 152146MB DWC OFF RA On Accept SPAN NO Choose RAID Level For This VD Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 6 Select RAID from the Virtual Drive sub menu and then press Enter 7 Select the RAID level from the menu and then press lt Enter gt Initial Objects Rebuild Check C Virtual Drive s Configured RAID Size Stripes Strips Status 1 148 580GB 2 64KB ONLINE Virtual Drive 0 RAID Level RAID 1 RAID 0 Units MB i 152146MB OFF On Choose RAID Level For This VD Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option Z10PE D16 Series 5 7 5 8 8 Select Units from the Virtual Drive sub menu and then press lt Enter gt 9 Select the units for virtual drive size from the menu and then press Enter Initial Objects Rebuild Check C Virtual Drive s Configured RAID Size Stripes StripSz 1 148 580GB 2 64KB Virtual Drive 0 RAID 1 Size 152146MB DWC Select Units For VD Size Status ONLINE Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 10 When creating a RAID 1 or a RAID 10 set select DWC from the Vi
76. apter 6 Driver Installation This chapter provides instructions for installing the necessary drivers for different system components Appendix This appendix includes additional information that you may refer to when configuring the motherboard Where to find more information Refer to the following sources for additional information and for product and software updates 1 ASUS websites The ASUS website provides updated information on ASUS hardware and software products Refer to the ASUS contact information 2 Optional documentation Your product package may include optional documentation such as warranty flyers that may have been added by your dealer These documents are not part of the standard package Xi xii Conventions used in this guide To ensure that you perform certain tasks properly take note of the following symbols used throughout this manual ASA Typography Bold text lt Key1 gt lt Key2 gt lt Key3 gt Command DANGER WARNING Information to prevent injury to yourself when trying to complete a task CAUTION Information to prevent damage to the components when trying to complete a task IMPORTANT Instructions that you MUST follow to complete a task NOTE Tips and additional information to help you complete a task Indicates a menu or an item to select Used to emphasize a word or a phrase Keys enclosed in the less than and greater than sign means that you must press the encl
77. arity bit can be sent with the data bits to detect some transmission errors Mark and Space parity do not allow for error detection None None Even parity bit is O if the num of 1 s in the data bits is even Odd parity bit is O if num of 1 s in the data bits is odd Mark parity bit is always 1 Space parity bit is always 0 Stop Bits 1 Stop bits indicate the end of a serial data packet A start bit indicates the beginning The standard setting is 1 stop bit Communication with slow devices may require more than 1 stop bit Configuration options 1 2 Flow Control Hardware RTS CTS Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signals Configuration options None Hardware RTS CTS VT UTF8 Combo Key Support Enabled This allows you to enable the VT UTF8 Combination Key Support for ANSI VT 100 terminals Configuration options Disabled Enabled Recorder Mode Disabled With this mode enabled only text will be sent This is to capture Terminal data Configuration options Disabled Enabled Legacy OS Redirection Resolution 80x24 This allows you to set the number of rows and columns supported on the Legacy OS Configuration options 80x24 80x25
78. ate then press lt Enter gt 4 From the Disks item field press lt Enter gt to select the hard disk drives that you want to include in the RAID set SELECT DISKS 5 Use the up down arrow keys to move the selection bar then press Space to select a disk A small triangle before the Port number marks the selected drive Press lt Enter gt when you are done 5 26 Chapter 5 RAID Configuration 6 Use the up down arrow keys to select the stripe size for the RAID array for RAID 0 10 and 5 only then press lt Enter gt The available stripe size values range from 4 KB to 128 KB The following are typical values RAID 0 128KB RAID 10 64KB RAID 5 64KB AN We recommend a lower stripe size for server systems and a higher stripe size for multimedia computer systems used mainly for audio and video editing 7 In the Capacity field item key in the RAID volume capacity that you want to use and press Enter The default value field indicates the maximum allowed capacity 8 Press Enter to start creating the RAID volume 9 From the following warning message press lt Y gt to create the RAID volume and return to the main menu or press lt N gt to go back to the CREATE VOLUME menu Are you sure you want to create this volume Y N Z10PE D16 Series 5 27 5 3 2 Deleting a RAID set AN Take caution when deleting a RAID set You will lose all data on the hard disk drives when you delete a RAID set
79. ation Configuration options Generic Mode High Speed Mode Full Speed Mode Manual Mode Chapter 4 BIOS Setup 4 9 Security menu This menu allows a new password to be created or a current password to be changed The menu also enables or disables the Secure Boot state and lets the user configure the System Mode state Aptio Setup Utility Copyright C 2013 American Megatrends Inc Administrator Password Administrator Password To set an administrator password 1 Select the Administrator Password item and press Enter 2 From the Create New Password box key in a password then press Enter 3 Confirm the password when prompted To change an administrator password 1 Select the Administrator Password item and press Enter 2 From the Enter Current Password box key in the current password then press Enter 3 From the Create New Password box key in a new password then press Enter 4 Confirm the password when prompted VA To clear the administrator password follow the same steps as in changing an administrator l password but press lt Enter gt when prompted to create confirm the password Z10PE D16 Series 4 43 4 44 User Password To set a user password 1 2 3 Select the User Password item and press lt Enter gt From the Create New Password box key in a password then press lt Enter gt Confirm the password when prompted To change a user password 1 2 3
80. ay Will Automatically Become A VD Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option Z10PE D16 Series 5 5 2 The ARRAY SELECTION MENU displays the available drives connected to the SATA ports Use the up down arrow keys to select the drives you want to include in the RAID set and then press lt Space gt When selected the drive indicator changes from READY to ONLIN A X Y where X is the array number and Y is the drive number Managem Initializ Objects Rebuild Check Con Easy Configuration ARRAY SELECTION MENU ONLIN A00 00 ONLIN A00 01 READY Port 2 DISK 74 74GB HDS728080PLA380 05 01C05 SPACE Sel ENTER EndArray F10 Configure F2 Drive Info F3 Virtual Drives F4 HSP aN e The information of the selected hard disk drive displays at the bottom of the screen e You need at least two identical hard disk drives when creating a RAID 1 set e You need at least four identical hard disk drives when creating a RAID 10 set 3 Select all the drives required for the RAID set and then press lt F10 gt to configure array setting 4 Press Space to select the configurable array Initializ Objects Rebuild Check Con Easy Configuration ARRAY SELECTION MENU Select Configurable Array s Cursor Keys SPACE De Select F2 Chidinfo F3 SlotInfo F10 Configure Esc Quit Chapter 5 RAID Configuration 5 Press lt F10 gt again the virtual drive information
81. ay a pop up window with the configuration options for that item 4 2 9 Scroll bar A scroll bar appears on the right side of a menu screen when there are items that do not fit on the screen Press the Up Down arrow keys or lt Page Up gt lt Page Down gt keys to display the other items on the screen Chapter 4 BIOS Setup 4 3 Main menu When you enter the BIOS Setup program the Main menu screen appears The Main menu provides you an overview of the basic system information and allows you to set the system date time language and security settings Aptio Setup Utility Copyright C 2013 American Megatrends Inc System Language 4 3 1 System Date Day xx xx xxxx Allows you to set the system date 4 3 2 System Time Xx Xx xx Allows you to set the system time Z10PE D16 Series 4 9 4 10 4 4 Advanced menu The Advanced menu items allow you to change the settings for the CPU and other system devices Take caution when changing the settings of the Advanced menu items Incorrect field values can cause the system to malfunction Aptio Setup Utility Copyright C 2013 American Megatrends Inc gt ACPI Settings Chapter 4 BIOS Setup 4 4 1 ACPI Settings Aptio Setup Utility Copyright C 2013 American Megatrends Inc Enable ACPI Auto Configuration Enable ACPI Auto Configuration Disabled Allows you to enable or disable the BIOS ACPI Auto Configuration Configuration options Disabled
82. bar to exit Save Changes amp Reset Exit System setup after saving the changes Discard Changes amp Exit Exit System setup without saving any changes Save Changes amp Reset Reset the system setup after saving the changes Discard Changes amp Reset Reset system setup without saving any changes Save Options Save Changes Save changes done so far to any of the setup options Discard Changes Discard changes done so far to any of the setup options Chapter 4 BIOS Setup Restore Defaults Restore load default values for all the setup options Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore the User Defaults to all the setup options Boot Override These items displays the available devices The device items that appears on the screen depends on the number of devices installed in the system Click an item to start booting from the selected device Launch EFI Shell from filesystem device Attempts to launch EFI Shell application shellx64 efi from one of the available filesystem devices Z10PE D16 Series 4 49 4 50 Chapter 4 BIOS Setup RAID Configuration This chapter provides instructions for setting up creating and configuring RAID sets using the available utilities 5 2 5 1 Setting up RAID The motherboard supports the following SATA RAID solutions LSI MegaRAID software RAID Configuration Utility with RAID 0 RAID 1 and RAID
83. cation LED The Location LED helps visually locate and quickly identify the server in error on a server rack Refer to section Onboard LEDs of this user guide for more information 8 Power LED This LED lights up when the Power on button is pressed and the system is on 9 USB 2 0 ports 7 and 8 These 4 pin Universal Serial Bus USB ports are available for connecting USB 2 0 devices 10 USB 3 0 ports 1 and 2 These 4 pin Universal Serial Bus USB ports are available for connecting USB 3 0 devices 2 32 Chapter 2 Hardware Information LAN port LED indications Z10PE D16 and Z10PE D16 4L Activity Link LED Speed LED 10 Mbps connection GREEN ORANGE 100 Mbps connection BLINKING Data activity GREEN 1 Gbps connection LAN port 1 2 LAN port 3 4 Z10PE D16 4L only ACT LINK SPEED ACTILINK SPEED LED LED eo B Eeoe Dedicated Management LAN port DM_LAN1 LED indications Activity Link LED Speed LED ACTED LED 10 Mbps connection ORANGE ORANGE 100 Mbps connection BLINKING Data activity GREEN 1 Gbps connection DM LAN port 10G LAN port LED indications Z10PE D16 10G 2T only ACT LINK SPEED Activity Link LED Speed LED LED LED 100M Speed GREEN YELLOW 1G Speed BLINKING Data activity GREEN 10G Speed eta an Z10PE D16 Series 2 33 2 8 2 Internal connectors 1 Serial ATA 6 0 Gbps connectors 7 pin SATA1 SATA2 SATA3 SATA4 SATA5 SATA6 Light Blue SSATA1 SSATA2 SSATA3 Gray SSATA4 Light Gray
84. ce controller It provides bandwidth intensive applications with highly affordable 10GbE network performance and cost effective RJ 45 connectivity It simplifies migration to 10GbE and provides flexible I O virtualization for port partitioning and quality of service of up to 64 virtual ports Intel 1350 AM2 BT2 LAN controller The motherboard comes with an integrated quad or dual port Gigabit LAN controller which provides a total solution for your networking needs The onboard Intel 1350 Gigabit controller is designed with high performance and can save platform power with Energy Efficient Ethernet EEE and DMA Coalescing features It also supports flexible I O virtualization which enhances network connectivity to more efficient models Serial ATA III technology The motherboard supports the Serial ATA III technology through the Serial ATA interface and Intel C612 chipset delivering up to 6 Gb s data transfer rates It also provides enhanced scalability faster data retrieval and double the bandwidth of current bus systems Temperature fan and voltage monitoring The CPU temperature is monitored to prevent overheating and damage The system fan rotations per minute RPM is monitored for timely failure detection The chip monitors the voltage levels to ensure a stable supply of current for critical components 1 4 2 Innovative ASUS features ASUS Fan Speed control technology The ASUS Fan Speed control technology smartly adjusts the fa
85. ce that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with manufacturer s instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment to an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help to assure compliance with FCC regulations Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment The use of shielded cables for connection of the monitor to the graphics card is reguired Canadian Department of Communications Sta
86. command 1 From the Management Menu select Check Consistency and then press lt Enter gt Management Menu Configure Initialize Objects Rebuild Check Consistenc CC of VD s Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option 2 The screen displays the available RAID set s and prompts you to select the virtual drive to check Press lt Space gt to select the virtual drive from the Virtual Drive sub menu and then press lt F10 gt Virtual ve s Configured Size Stripes StripSz Status Management Menu Con aa 148 580GB 2 64KB ONLINE Initialize Objects Rebuild Check Consistency Virtual Drives virtual Drive Of Select VD SPACE De Select F10 Initialize Chapter 5 RAID Configuration 3 When prompted use the arrow keys to select Yes from the Consistency Check dialog box and then press Enter Virtual Drive s Configured RAID Size Stripes StripSz Status as ana an 10 154494MB 2 64KB ONLINE Configure Initialize Virtual Drives Wvirtual Drive Of Select VD s SPACE De Select F10 Initialize A progress bar appears on screen Virtual Drive s Configured E T LD i Size Stripes StripSz Status ee CC Under Process ONLINE Initialize VD 0 Consistency Check Press Esc to Abort Onir Ps Rebuild Check Consistency 1855 Completed Virtual Drives en The Data On The Drives Is Inconsistency Repair Done SPACE De Select F10 Initial
87. ct Create Volume and select volume type 2 Click Next putusannya Intel R C600 C220 series chipset SATA RAID Controller 3 Confirm O Intel R C600 C220 series chipset sSATA RAID Controller r Protection Select Volume Type Performance Capacity Combine two disks to create a volume where each disk stores an exact copy of the data and provides real time redundancy 2 Configure Real time data protection RAID 1 O Optimized disk performance RAID 0 Efficient data hosting and protection RAID 5 Balanced performance and data protection RAID 10 D Cancel More help on this page 3 Enter a name for the RAID set then select the array disks 4 Select Volume Size tab you can drag the bar to decide the volume size 5 Click Next create voume 1 Select Configure Volume Proposed Configuration 2 Configure Name Volume_0000 New Array 3 Confirm 3 a j Volume_0000 Select the array disks minimum selection required M SAS disk on Controller 1 Phy 0 279 GB va Y M SAS disk on Controller 1 Phy 2 279 GB Volume Size Advanced Volume Size 4 468 MB Array allocation toy 20 Back Next Cancel More help on this page LN e Ifyou do not want to keep the data on one of the selected disks select NO when prompted e If you want to Enable volume write back cache or Initialize volume click Advanced 5 34 Chapter 5 RAID Configu
88. cts Rebuild 7 Initialize Check Consistency em No Virtual Drives Init Will Destroy Data On Selected VD s SPACE De Select F10 Initialize Initializing a virtual drive erases all data on the drive 4 A progress bar appears on screen If desired press lt Esc gt to abort initialization When initialization is completed press lt Esc gt Virtual Drive s Configured RAID Size Stripes StripSz Management Menu Configure Init of VD Is In Process DE As VD 0 Initialization Complete Press Esc Objects Rebuild Check Consisten 1 100 Completed Virtual Drives pe Drive 0 SPACE De Select F10 Initialize Z10PE D16 Series 5 13 5 14 Using the Objects command To initialize the virtual drives using the Objects command 1 From the Management Menu select Objects gt Virtual Drive and then press Enter LSI Software R Objects Adapter Virtual Drive Physical Drive Managment Initia ize Objects N Rebuild Bana Check Consistency Change VD Parameters Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2 Select the virtual drive to initialize from the Virtual Drives sub menu and then press Enter LSI Software R ri Virtual Drive 1 N Management Adapter J Dai prive o na laga F ee Physical Drive Te Anang x Rebuild Check Consistency Select VD Press ENTER To Select A VD lt Del gt To Delete A VD Chapt
89. disk 559 GB Vent is Verity Bee SAS disk 559 GB Parity errors 0 ors ea Blocks with media errors 0 SAS disk 559 GB Physical sector size 512 Bytes MJ SAS disk 559 GB Logical sector size 512 Bytes Gee SAS disk 559 GB GE SAS dik 559 GB GI SAS disk 559 GB v Intel R C600 series chipset SATA RAID Controller Gees SATA disk 559 GB MEI SATA disk 559 GB MI sata dick 559 GB Ges SATA disk 559 GB Z10PE D16 Series 5 35 5 4 2 Changing a Volume Type To change the volume type in Volume Properties 1 Click the SATA array items you want to change in Volumes field 2 From the Volume Properties field select Type RAID 1 Change type logy enterprise Volume Properties Name Volume_0000 Rename Volumes Status Normal Type RAID 1 Change type ize 4 406 MB Inc ncrease size system is functioning normally chipset SAS RAID Controller SAS_Array_0000 es r System volume No Delete volume Tj votume_o000 Write back cache Disabled Enable Initialized No Initialize Verification details Verify Parity errors 0 Blocks with media errors 0 Physical sector size 512 Bytes Logical sector size 512 Bytes 3 You can change the Name Select the new volume type and Select additional disks to include in the new volume if needed 4 Select the Data stripe size for the RAID array for RAID 0 10 and 5 only and click OK The available stripe s
90. e Amme License Agreement You must accept all of the terms of the license agreement in order to continue the setup program Do you accept the terms INTEL SOFTWARE LICENSE AGREEMENT Alpha Beta Organizational Use IMPORTANT READ BEFORE COPYING INSTALLING OR USING Do not use or load this software and any associated materials collectively the Software until you have carefully read the following terms and conditions By loading or using the Software you agree to the terms of this Agreement If you do not wish to so agree do not install or use the Software The Software contains pre release alpha or beta code which may not be fully functional and which Intel Corporation Intel may substantially modify in producing any final version of the Software Intel can provide no assurance that it will ever produce or make generally lt Back Yes 7 Readme File Information Refer to the Readme file below to view the system requirements and installation information KEEKEEKE EEEE EDE DE IE DE IE IE IE IE JE IE IE IE IE IE JE IE IE JE IE IE IE IE IE IE IE IE IE IE IE IE PKK KK EK KK KK KKM KK KK KK KK KKM KK IEKE EIEE IEE EEIEIEE EIEEE Installation Readme for Intel R Rapid Storage Technology enterprise Intel R RSTe Refer to the system requirements for the operating systems supported by Intel R Rapid Storage Technology enterprise This document makes references to products de
91. e RT32 Image Loading Configuration options Disabled Enabled Above 4G Decoding Disabled Allows you to enable or disable 64 bit capable devices to be decoded in above 4G address space It only works if the system supports 64 bit PCI decoding Configuration options Disabled Enabled SR IOV Support Disabled This option enables or disables SIngle Root IO Virtualization Support if the system has SR IOV capable PCle devices Configuration options Disabled Enabled Z10PE D16 Series 4 19 4 20 4 4 9 Network Stack Configuration Aptio Setup Utility Copyright C 2013 American Megatrends Inc Network Stack Network stack Disabled Enables or disables the network stack feature Configuration options Disable Enable Z The following item appears only when Network stack is set to Enabled Ipv4 PXE Support Enabled Enables or disables the Ipv4 PXE Boot Support If disabled Ipv4 PXE boot option will not be created Configuration options Disabled Enabled Ipv6 PXE Support Enabled Enables or disables the Ipv6 PXE Boot Support If disabled Ipv6 PXE boot option will not be created Configuration options Disabled Enabled PXE boot wait time 0 Wait time to press ESC key to abort the PXE boot Media detect time 0 Wait time in seconds to detect media Chapter 4 BIOS Setup 4410 CSM Configuration Aptio Setup Utility Copyright C 2013 American Megatrends Inc CSM Support
92. e you start using this utility download the latest BIOS from the ASUS website at www asus com To update the BIOS using EZ Flash Utility 1 Insert the USB flash disk that contains the latest BIOS file into the USB port 2 Enter the BIOS setup program Go to the Tool menu then select ASUS EZ Flash Utility Press lt Enter gt ASUS Tek EzFlash Utility Current Platform New Platform Platform Z10PE D16 Platform Z10PE D16 Version 0020 Version 0022 Build Date 04 25 2014 Build Date 05 05 2014 System Volume Information Windows Up Down Left Right Switch Enter Choose q Exit 3 Press lt Tab gt to switch to the Drive field 4 Press the Up Down arrow keys to find the USB flash disk that contains the latest BIOS then press Enter 5 Press Tabs to switch to the Folder Info field Z10PE D16 Series 4 3 4 4 6 Press the Up Down arrow keys to find the BIOS file and then press Enter to perform the BIOS update process Reboot the system when the update process is done AN e This function can support devices such as a USB flash disk with FAT 32 16 format and single partition only e DO NOT shut down or reset the system while updating the BIOS to prevent system boot failure BRN Ensure to load the BIOS default settings to ensure system compatibility and stability Press lt F5 gt and select Yes to load the BIOS default settings 4 1 3 BUPDATER utility The succeeding BIOS screens are for re
93. eads are for the intrusion detection feature for chassis with intrusion sensor or microswitch When you remove any chassis component the sensor triggers and sends a high level signal to these leads to record a chassis intrusion event The default setting is short CHASSIS and GND pin by jumper cap to disable the function Eee ee m INTRUSION B CHASSIS GND m ef cam o om Ti PIN 1 Z10PE D16 Series Chassis Intrusion connector Foo Z10PE D16 Series 2 43 Chapter 2 Hardware Information Powering Up This chapter describes the power up seguence and ways of shutting down the system 3 1 a Aa ae N Starting up for the first time After making all the connections replace the system case cover Be sure that all switches are off Connect the power cord to the power connector at the back of the system chassis Connect the power cord to a power outlet that is equipped with a surge protector Turn on the devices in the following order a Monitor b External storage devices starti
94. echnology enterprise SATA SSATA Option ROM utility 1 Tumon the system 2 During POST press lt Ctrl gt lt I gt to display the utility main menu Intel R Rapid Storage Technology enterprise SATA Option ROM 3 6 0 1023 Copyright C 2003 12 Intel Corporation All Rights Reserved 1 Create RAID Volume 3 Reset Disks to Non RAID 2 Delete RAID Volume 4 Exit RAID Volumes None defined Physical Disks ID Drive Model Serial Size Type Status Vol ID 0 ST3300656SS HWAS0000991753TR 219 3GB 1 ST3300656SS 37VN00009846RAJ1 279 3GB 2 ST3300656SS 39760000984 6UEDY 2179 3GB 3 ST3300656SS GWC50000991756G6 279 3GB t Select ESC Exit ENTER Select Menu The navigation keys at the bottom of the screen allow you to move through the menus and select the menu options The RAID BIOS setup screens shown in this section are for reference only and may not exactly match the items on your screen Z10PE D16 Series 5 25 5 3 1 Creating a RAID set To create a RAID set 1 From the utility main menu select 1 Create RAID Volume and press lt Enter gt 2 Key in a name for the RAID set and press lt Enter gt CREATE VOLUME MENU Name RAID Level RAIDO Strips Disks Select Disks Strip Size 128KB Capacity 0 0 GB Syne N A Create Volume Enter a unique volume name that has no special characters and is 16 characters or less 3 Press the up down arrow keys to select a RAID Level that you wish to cre
95. ed on Windows Server 2008 R2 and Windows Server 2012 6 3 Running the Support DVD When you place the support DVD into the optical drive the DVD automatically displays the main screen if Autorun is enabled in your computer By default the Drivers tab is displayed locate the file ASSETUP EXE from the BIN folder Double click the ASSETUP EXE to Z If Autorun is NOT enabled in your computer browse the contents of the support DVD to e run the support DVD The main screen of the Support DVD contains the following tabs 1 Drivers 2 Utilities 3 MakeDisk 4 Manual 5 Contact The main screen of the Support DVD looks exactly the same on the Windows Server 2008 R2 and on the Windows Server 2012 Operating System OS Pena Z10PE D16 Series 6 13 6 3 1 Drivers menu tab The Drivers Menu shows the available device drivers if the system detects installed devices Install the necessary drivers to activate the devices ASUS InstAll Drivers Installation Wizard Please select items to install Intel Chipset Device Software Intel 1350 AM4 1350 AM2 1210 X540 B1I ASPEED AST2300 ASTi2400 Display Dr Intel R C610 series Chipset SATAAHCIL Intel C610 MEI NULL HECI Driver 6 3 2 Utilities menu tab The Utilities menu displays the software applications and utilities that the motherboard supports Utilities ASUS InstAll Installation Wizard fonUtili ease select items to install Intel Rapid Storage Wjechnologyjenterp
96. ees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure If you require assistance please call ASUS Customer Service 1300 2787 88 or visit us at http support asus com About this guide This user guide contains the information you need when installing and configuring the motherboard How this guide is organized This user guide contains the following parts Chapter 1 Product Introduction This chapter describes the features of the motherboard and the new technologies it supports Chapter 2 Hardware Information This chapter lists the hardware setup procedures that you have to perform when installing system components It includes description of the switches jumpers and connectors on the motherboard Chapter 3 Powering Up This chapter describes the power up sequence and ways of shutting down the system Chapter 4 BIOS Setup This chapter tells how to change system settings through the BIOS Setup menus Detailed descriptions of the BIOS parameters are also provided Chapter 5 RAID Configuration This chapter provides instructions for setting up creating and configuring RAID sets using the available utilities Ch
97. efault secure keys otherwise select No Save All Secure Boot Variables This item will ask you if you want to save all secure boot variables Select Yes if you want to save all secure boot variables otherwise select No Platform Key PK Key Exchange Key KEK Authorized Signatures DB Authorized TimeStamps DBT Forbidden Signatures DBX Configuration options Delete Set New Append Z10PE D16 Series 4 45 4 46 4 10 Boot menu The Boot menu items allow you to change the system boot options Aptio Setup Utility Copyright C 2013 American Megatrends Inc Setup Prompt Timeout Setup Prompt Timeout xx Use the lt gt and lt gt keys to adjust the number of seconds to wait for setup activation key Bootup NumLock State On Allows you to select the power on state for the NumLock Configuration options Off On Boot Logo Display Auto Allows you to enable or disable the full screen logo display feature Configuration options Auto Full Screen Disabled POST Report 5 sec Allows you to set the desired POST Report waiting time from 1 to 10 seconds Configuration options 1 sec 10 sec Until Press ESC Chassis Intrusion Warning Allows you to set an action when chassis intrusion has occurred Configuration options Warning Halt Boot Option Priorities These items specify the boot device priority sequence from the available devices The number of device items that appears on the
98. effect after reboot Configuration options Disabled Enabled Chapter 4 BIOS Setup Enable SMX Disabled Enables the Safer Mode Extensions Configuration options Disabled Enabled Hardware Prefetcher Enabled This Item allows you to turn on off the mid level cache L2 streamer prefetcher Configuration options Disabled Enabled Adjacent Cache Prefetch Enabled This Item allows you to turn on off prefetching of adjacent cache lines Configuration options Disabled Enabled DCU Streamer Prefetcher Enabled This Item allows you to enable or disable prefetcher of next L1 data line Configuration options Disabled Enabled DCU IP Prefetcher Enabled This Item allows you to enable or disable prefetch of next L1 line based upon sequential load history Configuration options Disabled Enabled DCU Mode 32K 8Way Without ECC Configuration options 32K 8Way Without ECC 16K 4Way With ECC Direct Cache Access DCA Auto This Item allows you to enable or disable Direct Cache Access Configuration options Auto Disabled Enabled DCA Prefetch Delay 32 This Item allows you to set the time for the DCA Prefetch delay Help Configuration options Disabled 8 16 24 32 40 48 56 64 72 80 88 96 104 112 X2APIC Disabled This Item allows you to enable or disable the extended APIC support Configuration options Disabled Enabled AES NI Enabled This Item allows you to en
99. egatrends Inc OS Watchdog Timer OS Watchdog Timer Disabled This item allows you to start a BIOS timer which can only be shut off by Intel Management Software after the OS loads Configuration options Disabled Enabled V The following items is configurable only when the OS Watchdog Timer is set to Enabled OS Wtd Timer Timeout 10 minutes Allows you to configure the length of the OS Boot Watchdog Timer Configuration options 5 minutes 10 minutes 15 minutes 20 minutes OS Wtd Timer Policy Reset This item allows you to configure the how the system should respond if the OS Boot Watch Timer expires Configuration options Do Nothing Reset Power Down Serial Mux Disabled This item allows you to enable or disable Serial Mux configuration Configuration options Disabled Enabled Chapter 4 BIOS Setup System Event Log Allows you to change the SEL event log configuration SEL Components Enabled Allows you to enable or disable all features of system Event Logging during boot Configuration options Disabled Enabled e The following items appears only when you set SEL Components to Enabled Z e All values changed here do not take effect until computer is restarted Erase SEL No Allows you to choose options for erasing SEL Configuration options No Yes On next reset Yes On every reset When SEL is Full Do Nothing Allows you to choose options for reactions to a full SEL
100. el VT for Directed I O VT d Enabled Allows you to enable or disable the Intel Virtualization Technology for Directed I O Configuration options Disabled Enabled PCI Express Global Options TX EQ WA Enabled Use special table for TX_EQ and vendor specific cards Configuration options Disabled Enabled PCle ASPM Support Global L1 Only This option enables or disables the ASPM support for all downstream devices Configuration options Disabled L1 Only Chapter 4 BIOS Setup 4 5 7 PCH Configuration PCH Devices DeepSx Power Policies Disabled Allows you to configure the DeepSx Mode configuration Configuration options Disabled Enabled in S5 Enabled in S4 and 5 PCI Express Configuration PCH DMI ASPM Enabled Allows you to configure the PCH DMI ASPM Configuration options Disabled Enabled PCI Express Root Port 1 to Port 8 Allows you to configure the PCI Express Root port settings PCle ASMP Disable ASPM Allows you to configure the PCH DMI ASPM Configuration options Disable ASPM ASPM LOs ASPM L1 ASPM LOsL1 ASPM Auto PCH sSATA Configuration SSATA Controller Enabled Allows you to enable or disable the sSATA Controller Configuration options Disabled Enabled Configure sSATA as AHCI Allows you to identify the SATA port is connected to Solid State Drive or Hard Disk Drive Configuration options IDE AHCI RAID SATA Mode options SATA LED locate Enabled If
101. elect the boot option priority 3 Use up down arrow keys to select the boot priority and press lt Enter gt See the Boot menu section of Chapter 4 for more details 4 From the Exit menu select Save Changes amp Exit then press lt Enter gt 5 When the confirmation window appears select Yes then press lt Enter gt 5 32 Chapter 5 RAID Configuration 5 4 Intel Rapid Storage Technology enterprise Windows The Intel Rapid Storage Technology enterprise allows you to create RAID 0 RAID 1 RAID 10 RAID 1 0 and RAID 5 set s from Serial ATA hard disk drives that are connected to the Serial ATA connectors supported by the Southbridge aN You need to manually install the Intel Rapid Storage Technology enterprise utility ona Windows operating system Please refer to the installation instructions in Chapter 6 To enter the Intel Rapid Storage Technology enterprise utility under Windows operating system 1 Turn on the system and go to the windows desktop 2 Click the Intel Rapid Storage Technology enterprise icon to display the main menu Your storage system is configured for data protection increased performance and optimal data storage capacity You can create additional volumes to further optimize your storage system Z You can click Rescan to re scan any attached hard disks S Z10PE D16 Series 5 33 5 4 1 Creating a RAID set To create a RAID set 1 From the utility main menu sele
102. elephone 008 800 100 ASUS 008 800 100 2787 Online Support http vip asus com eservice techserv aspx SLanguage ru Appendix u aneus GLO Hunew 39 Burxijye ulbaq 0 123A GLOZ S0 8 4 9 eq UoIyesejdag P 99110D bLo0Z 90 2 9 eq uoneejoaq eUIBLIC UeyS Aap owen O39 uONIsod Bumeu AlwJojuod 93 9ZE0SL 3A bunjew 39X anipeiid SHOu Nn3 59 LLozXI L02 Z19 ON NJ Uonen6ey 6002 8142 ON 92 uoein6ay 6002 29 ON 93 uonein6ay 8002 5121 ON 92 uonyein6ay C ONIPAMIG d13 23 521 6002L 1 LLOZ GLV 6006 59009 NA o0 LOZ 2v 9002 1 05609 N3 O LLOC Z Y 9002 1 09609 N3 I n 11d dA1 93 96 900Z H 102 9990S NA 20 G00Z Lk LA Z 162 ZOE NA Z0 G00Z Lk LA L L62 ZOE NI L1 8002 lb LA 2 ZG LOE NA 60 2002 L E LA 9ZE ZOE NA 90 2002 2 2 LA 2 9ZE ZOE NA 60 002 L S LA vz 68p LOE NA 60 zL02 1 z zA Z1 68p LOE NA LL 2002 Lv LA 6 68 LOE NA LI 9002 L E LA 2 68 LOE NA S0 6002 Lv LA t 68 LOE NA 80 2002 lv LA 68t LOE Na 60 1 102 2 6 LA 1 68 LOE NA 800Z L 29 NA Z002 S8E0S NA 0102 64p29 NA L00Z 09 03 N3 10 6002 1 1 LA z9 ZOE NA 10 6002 KY LA 2 pvS Zoe NA 90 2102 IZ LA 68 LOE N3 20 1 LOZ 2 SA 2 806 LOE Na GO 1 LOZ SA 1 806 LOS Na 0 002 Z 0 6A LIS LOE NA 80 0102 l Y LA Z Ovb 00 NA 80 0102 lO LA I Ort 00 Na 90 2102 18 LA gz 00 N ND DD Saad ALI8H DA 5 6661 L LOZ LL V 100G 020SS
103. en it flips out with extra force Z10PE D16 Series 2 17 2 5 Expansion slots In the future you may need to install expansion cards The following subsections describe the slots and the expansion cards that they support Ensure to unplug the power cord before adding or removing expansion cards Failure to do so may cause you physical injury and damage motherboard components 2 5 1 Installing an expansion card To install an expansion card 1 Before installing the expansion card read the documentation that came with it and make the necessary hardware settings for the card 2 Remove the system unit cover if your motherboard is already installed in a chassis 3 Remove the bracket opposite the slot that you intend to use Keep the screw for later use 4 Align the card connector with the slot and press firmly until the card is completely seated on the slot 5 Secure the card to the chassis with the screw you removed earlier 6 Replace the system cover 2 5 2 Configuring an expansion card After installing the expansion card configure it by adjusting the software settings 1 Turn on the system and change the necessary BIOS settings if any See Chapter 4 for information on BIOS setup 2 Assign an IRQ to the card Refer to the table Standard Interrupt assignments in section Interrupt assignments for more information _ 3 Install the software drivers for the expansion card Rn When using PCI cards on
104. er 5 RAID Configuration 3 Select Initialize from the pop up menu and then press lt Enter gt to start initialization Gerne ESG Virtual Drive Initialize Rebuild Virtual TENI Check Consistency Check Consistency View Update Parameters DESEE Virtual Drive 1 Man ment J Virtual Drive 0 anage Adapter Physical Driv Initialize VD Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option When prompted press the lt Space gt to select Yes from the Initialize dialog box and then press lt Enter gt Objects Management Adapter pone gure Initialize Physical Drive Objects Rebuild Check Consistency ie 1d Snae rame No Init Will Destroy Data On Selected VD s Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option A progress bar appears on screen If desired press lt Esc gt to abort initialization When initialization is completed press lt Esc gt Z10PE D16 Series 5 15 5 16 5 2 4 Rebuilding failed drives You can manually rebuild failed hard disk drives using the Rebuild command in the Management Menu To rebuild a failed hard disk drive 1 From the Management Menu select Rebuild and then press Enter Management Menu Configure Initialize Objects Rebuild Check Consistency Rebuild VD s Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option 2 The PHYSICAL DRIVES SELECTION MENU displays
105. ess lt Enter gt when you are done Resetting RAID disk will remove its RAID structures and revert it to a non RAID disk This does not apply to Recovery volumes Port Drive Model Serial Size Status 0 ST3300656SS HWAS0000991753TR 219 3GB Member Disk 1 ST3300656SS 37VN00009846RAJ1 219 3GB Member Disk Select the disks that should be reset If 1 Previous Next SPACE Selects ENTER Selection Complete Press lt Y gt in the confirmation window to reset the drive s or press lt N gt to return to the utility main menu Z10PE D16 Series 5 29 5 3 4 Exiting the Intel Rapid Storage Technology enterprise SATA SSATA Option ROM utility To exit the utility Ts From the utility main menu select 4 Exit then press Enter 2 Press lt Y gt to exit or press lt N gt to return to the utility main menu I Are you sure you want to exit Y N 5 3 5 Rebuilding the RAID Rn This option is only for the RAID 1 set Rebuilding the RAID with other non RAID disk If any of the SATA hard disk drives included in the RAID 1 array failed the system displays the status of the RAID volume as Degraded during POST You can rebuild the RAID array with other installed non RAID disks To rebuild the RAID with other non RAID disk 1 During POST press lt Ctrl gt lt I gt at the prompt to enter the Intel Rapid Storage Technology option ROM utility 2 If there is a non RAID SATA Hard Disk available the uti
106. ference only The actual BIOS screen displays aN may not be the same as shown The BUPDATER utility allows you to update the BIOS file in the DOS environment using a bootable USB flash disk drive with the updated BIOS file Updating the BIOS file To update the BIOS file using the BUPDATER utility 1 Visit the ASUS website at www asus com and download the latest BIOS file for the motherboard Save the BIOS file to a bootable USB flash disk drive 2 Copy the BUPDATER utility BUPDATER exe from the ASUS support website at support asus com to the bootable USB flash disk drive you created earlier 3 Boot the system in DOS mode then at the prompt type BUPDATER i filename CAP where filename is the latest or the original BIOS file on the bootable USB flash disk drive then press lt Enter gt A gt BUPDATER i file name CAP Chapter 4 BIOS Setup 4 The utility verifies the file then starts updating the BIOS file ASUS Tek EzFlash Utility Curiam Plato New Platform Placroam 4 ALOPESDILE Placroei ZALORE DILG Version 2 0215 Version 2 0217 Buile caress 05 13 2014 Build date 06 30 2014 Start Programming Plash DO NOT SHUTDOWN TAB SYSTEM Write 15 failure AN DO NOT shut down or reset the system while updating the BIOS to prevent system boot 5 The utility returns to the DOS prompt after the BIOS update process is completed Reboot the system from the hard disk drive The BIOS update is finished
107. figuration options Lower Case Upper Case IPv6 BMC Lan Option Enable This item allows you to enable or disable the IPv6 BMC LAN channel function Disabling this item will not modify any BMC network during BIOS phase Configuration options Disable Enable IPv6 BMC LAN IP Address source Previous State Select to configure LAN channel parameters statically or dynamically by BIOS or BMC Configuration options Previous State Static Dynamic Obtained by BMC running DHCP Chapter 4 BIOS Setup Z The following items appear only when you set IP BMC Lan IP Address Source to Static Ta IPv6 BMC LAN IP Address Allows you to input IPv6 BMC Lan IP address IPv6 BMC LAN IP Prefix Length Allows you to input IPv6 BMC Lan IP Prefix Length IPv6 BMC LAN Default Gateway Allows you to input IPv6 BMC Lan Default Gateway IPv6 BMC LAN DNS Settings Allows you to enter IPv6 BMC LAN DNS Settings IPv6 BMC LAN Link IP Address Allows you to enter IPv6 BMC LAN Link IP address IPv6 BMC LAN Link IP Prefix Length Allows you to input IPv6 BMC Lan Link IP Prefix Length IPv6 BMC Lan Option Enable This item allows you to enable IPv6 BMC LAN channel function Disabling this option will not modify any BMC network during BIOS phase Z The following item appears only when you set IP BMC Lan Option to Enable Pem IPv6 BMC LAN IP Address Source Previous State Select to configure LAN channel parameters statically or dynamicall
108. ify the server error on a server rack LOCLED2 oo e e U BF Io Z10PE D16 Series Location LED 6 DIMM warning LED MEMERRA1 MEMERRA2 MEMERRB1 MEMERRB2 MEMERRC1 MEMERRC2 MEMERRD1 MEMERRD2 MEMERRE1 MEMERRE2 MEMERRF1 MEMERRF2 MEMERRG1 MEMERRG2 MEMERRH1 MEMERRH2 The DIMM warning LEDSs light up to indicate failure on the corresponding DIMMs Q 1 MEMERRGI1 CI MEMERRA1 KARAHA AAA EEE OF Ao MEMERRG2 C MEMERRA2 Eo Sars fo MEMERRH1 KI MEMERRB1 i ia MEMERRH2 C MEMERRB2 rar i DMEMERRF2 C MEMERRD2 i CD MEMERRF1 KJ MEMERRD1 pa Mann o i CJ MEMERRE2 CI MEMERRC2 oa a C MEMERRE1 KA MEMERRC1 pn i H gee i 2 Z10PE D16 Series ERR DIMM LED Z The warning LEDs only fu
109. iler Operation safety Before installing the motherboard and adding devices on it carefully read all the manuals that came with the package Before using the product make sure all cables are correctly connected and the power cables are not damaged If you detect any damage contact your dealer immediately To avoid short circuits keep paper clips screws and staples away from connectors slots sockets and circuitry Avoid dust humidity and temperature extremes Do not place the product in any area where it may become wet Place the product on a stable surface If you encounter technical problems with the product contact a qualified service technician or your retailer DO NOT throw the motherboard in municipal waste This product has been designed to enable proper reuse of parts and recycling This symbol of the crossed out wheeled bin indicates that the product electrical and electronic equipment should not be placed in municipal waste Check local regulations for disposal of electronic products DO NOT throw the mercury containing button cell battery in municipal waste This symbol of the crossed out wheeled bin indicates that the battery should not be placed in municipal waste Australia statement notice From 1 January 2012 updated warranties apply to all ASUS products consistent with the Australian Consumer Law For the latest product warranty details please visit http support asus com Our goods come with guarant
110. ion 1 3 Serial number label Before reguesting support from the ASUS Technical Support team you must take note of the motherboard s serial number containing 12 characters xxS2xxxxxxxx shown in the figure below With the correct serial number of the product ASUS Technical Support team members can then offer a quicker and satisfying solution to your problems Z10PE D16 Series Made in China ANA XXS2XXXXXXXX at 1 4 Special features 1 4 1 Product highlights Latest Processor Technology The motherboard supports Intel Xeon processor E5 2600 V3 product family which provides compelling IPC increases for legacy performance improvements floating point improvement easier multi core programming and with next generation processor power management Intel Xeon processor E5 2600 v3 product family also improve the I O capabilities and support QPI link speed of up to 9 6GT s Intel AVX 2 0 Intel AVX 2 0 extends 256 bit vector support for integer vector operations doubles fixed point arithmetic throughput adds support for new vector gather permutes blend vector shifts resulting in fixed and floating point algorithm improvements Also Intel s new microarchitecture doubles the cache bandwidth at L1 L2 to support higher FLOPS and contributes to greater performance in signal and image processing applications Next Generation of processor power management Intel Xeon processor E5 2600 v3 product family enhances the processor power man
111. irmware Test Memory Test Boot Options F1 Help F2 Language F3 Video Mode F4 Source F5 Kernel F6 Driver English US 800 x 600 DVD Default No Z10PE D16 Series 4 Use the USB drive to provide the third party driver during the OS installation Type the command brokenmodules ahci in Boot Options field and press lt Enter gt SUSE Linux Enterprise Server Boot from Hard Disk Repair Installed System Rescue System Check Installation Media Firmware Test Memory Test Boot Options brokenmoduleszahci F1 Help Language Video Mode F4 Source F5 Kernel F6 Driver English US 800 x 600 DVD Default Yes 5 When below screen appears select the USB floppy disk drive sda as the driver update medium Select OK then press lt Enter gt Please choose the Driver Update medium sda USB Floppy other device OK Back 6 Select Back and follow the onscreen instructions to finish the installation Chapter 6 Driver Installation 6 2 Management applications and utilities installation The support DVD that is bundled with your motherboard contains drivers management applications and utilities that you can install to maximize the features of your motherboard 1 The contents of the support DVD are subject to change at any time without notice Visit the ASUS website www asus com for the latest updates on software and utilities 2 The support DVD is support
112. is connector functions only when you enable the ASUS ASMB8 C LN Power supply is required to meet PMBus specification and customized BMC FW may be needed Please contact ASUS if your need further support 9 Serial port connector 10 1 pin COM1 This connector is for the serial COM port Connect the serial port module cable to one of these connectors then install the module to a slot opening at the back of the system chassis n EEE h l RXD1 DTR1 DSR1 CTS1 OLAH HH GND RTS1 RT1 DCD1 TXD1 COM1 PIN 1 a mM 2 U EF Ioi Z10PE D16 Series Serial port connectors Chapter 2 Hardware Information 10 11 Z10PE D16 Series Trusted Platform Module connector 20 1 pin TPM1 This connector supports a Trusted Platform Module TPM system which can securely store keys digital certificates passwords and data A TPM system also helps enhance network security protects digital identities and ensures platform integrity f Io TE h EEI
113. ize 4 While checking the disk consistency press lt Esc gt to display the following options e Stop Stops the consistency check The utility stores the percentage of disk checked and when you restart checking it continues from the last percentage completed rather than from zero percent e Continue Continues the consistency check e Abort Aborts the consistency check When you restart checking it continues from zero percent 5 When checking is complete press any key to continue Z10PE D16 Series 5 19 5 20 Using the Objects command To check data consistency using the Objects command 1 From the Management Menu select Objects and then select Virtual Drive from the sub menu Use the arrow keys to select the virtual drive you want to check and then press Enter Select Check Consistency from the pop up menu and then press Enter When prompted use the arrow keys to select Yes from the dialog box to check the drive When checking is complete press any key to continue Chapter 5 RAID Configuration 5 2 6 Deleting a RAID configuration To delete a RAID configuration 1 From the Management Menu select Configure gt Clear Configuration and then press Enter Configuration Menu Easy Configuration View Add Configuration Initialize Clear Configuration Objects Select Boot Drive Rebuild Check Consistency Clear Existing Configuration Use Cursor Keys To Navigate Between Items A
114. ize values range from 4 KB to 128 KB The following are typical values RAID 0 128KB RAID 10 64KB RAID 5 64KB Change Volume Type xj Demam Select the new volume type Optimized disk performance RAID 0 O Efficient data hosting and protection RAID 5 O The new volume will automatically include the disks that are part of the existing volume Select additional disks to include in the new volume D SAS disk on Controller 1 Phy 4 SAS disk on Controller 1 Phy 6 WARNING Completing this action will immediately start the volume migration process Any data on the disks to be added to the volume will be permanently lost and should be backed up before continuing Volume data will be preserved Performing a driver upgrade or downgrade while a volume migration is in progress may make the volume inaccessible due to driver incompatibility More help OK We recommend a lower stripe size for server systems and a higher stripe size for multimedia computer systems used mainly for audio and video editing 5 36 Chapter 5 RAID Configuration 5 4 3 Deleting a volume Be cautious when deleting a volume You will lose all data on the hard disk drives Before you proceed ensure that you back up all your important data from your hard drives To delete a volume 1 From the utility main menu select the volume exp Volume 0000 in Volumes field you want to delete logy enterprise system is functioning norma
115. le CPU configuration Single CPU configuration must be installed on CPU1 Dual CPU configuration You can refer to the following recommended memory population for a dual CPU configuration Dual CPU configuration 2 16 Chapter 2 Hardware Information 2 4 3 Installing a DIMM on a single clip DIMM socket 1 Press the retaining clip outward to DIMM notch unlock the DIMM socket 2 Align a DIMM on the socket such that the notch on the DIMM matches the DIMM slot key on the socket DIMM slot key Unlocked retaining clip aN A DIMM is keyed with a notch so that it fits in only one direction DO NOT force a DIMM into a socket in the wrong direction to avoid damaging the DIMM 3 Hold the DIMM at both ends then insert the DIMM into the socket Apply force to both ends of the DIMM simultaneously 4 until the retaining clip clicks into place oir and the DIMM is seated securely in 4 z place Locked Retaining Clip e To install two or more DIMMs refer to the user guide bundled with the motherboard package AN Always insert the DIMM into the socket VERTICALLY to prevent DIMM notch damage e Refer to the user guide for qualified vendor lists of the memory modules Removing a DIMM from a single clip DIMM socket 1 Press the retaining clip outward to unlock the DIMM 2 Remove the DIMM from the socket Support the DIMM lightly with your fingers when pressing the retaining clips The DIMM might get damaged wh
116. lity will prompt you to rebuild the RAID Press the up down arrow keys to select the destination disk then Press lt Enter gt to start the rebuilding process or press lt ESC gt to exit Degraded volume and disk available for rebuilding detected Selectign a disk initiates a rebuild Rebuild completes in the operating system Select the port of destination disk for rebuilding ESC to exit Port Drive Model Serial Size X 0 0 0 0 0 00 0 0 014 0 0 0 0 00 04 XXX GB t Previous Next ENTER Select ESC Exit aN Select a destination disk with the same size as the original hard disk 5 30 Chapter 5 RAID Configuration 3 The utility immediately starts rebuilding after the disk is selected When done the status of the degraded RAID volume is changed to Rebuild Intel R Rapid Storage Technology enterprise SATA Option ROM 3 6 0 1023 Copyright C 2003 12 Intel Corporation All Rights Reserved 1 Create RAID Volume 3 Reset Disks to Non RAID 2 Delete RAID Volume 4 Exit RAID Volumes Data is Encrypted ID Name Levell Size Status Bootable 1 Volume0 RAID1 Mirror 149 0GB Yes Physical Devices Port Drive Model Serial Size Type Status Vol ID 1 ST3160812AS 9LSOF4HL 149 0GB 2 ST3160812AS 3LSOJYL8 149 0GB t Select ESC Exit ENTER Select Menu 4 Press lt Esc gt to exit Intel Rapid Storage Technology and reboot the system 5 Select Start gt Programs gt Intel Rapid St
117. lly Volume Properties Name Volume 0000 Rename Volumes Status Normal Type RAID 1 Change type chipset SAS RAID Controller SAS Array 0000 Size 4 468 MB Increase size asa System volume No Delete volume Write back cache Disabled Enable Y Initialized No Initialize D Verification details Verify Parity errors 0 Blocks with media errors 0 Physical sector size 512 Bytes Logical sector size 512 Bytes 2 Select Delete volume in Volume Properties field The following screen appears Delete Volume x Are you sure you want to delete this volume 4 WARNING Completing this action will permanently delete existing data on the selected volume Back up data before continuing More help Yes No 3 Click Yes to delete the volume and return to the utility main menu or click No to return to the main menu Z10PE D16 Series 5 37 5 38 5 4 4 Preferences System Preferences Allow you to set to show the notification area icon and show system information warning or errors here Intel Rapid Storage Technology enterprise eee t mail M Show the notification area icon Show the fallawing notifications M Storage system information V Storage system warnings v Storage system errors More help on this page E Mail Preferences Allow you to set to sent e mail of the following events Storage system information Storage system warnings Storage system errors
118. motherboard ASUS will process Return Merchandise Authorization RMA requests only if the motherboard comes with the cap on the LGA 2011 3 socket e The product warranty does not cover damage to the socket contacts resulting from incorrect CPU installation removal or misplacement loss incorrect removal of the PnP cap 2 3 1 Installing the CPU To install a CPU 1 Locate the CPU socket on the motherboard Io A h io BE ana mm 7 Z10PE D16 Series CPU LGA2011 3 Socket Co lon aN Before installing the CPU ensure that the socket box is facing toward you and the triangle mark is on the top right position Triangle R mark 2 10 Chapter 2 Hardware Information 2 Press the left load lever down with your thumb A move it to the right until it is released from the retention tab B then gently lift the load lever C AN To prevent damage to the socket pins do not remove the PnP cap unless you are installing a CPU Load lever 3 Press the right load lever with your thumb D move it to the left until
119. n speeds according to the system loading to ensure a quiet cool and efficient operation Chapter 1 Product Introduction Hardware Information This chapter lists the hardware setup procedures that you have to perform when installing system components It includes description of the jumpers and connectors on the motherboard 2 1 Before you proceed Take note of the following precautions before you install any motherboard component or change any motherboard settings AN e Unplug the power cord from the wall socket before touching any component e Use a grounded wrist strap or touch a safely grounded object or a metal object such as the power supply case before handling components to avoid damaging them due to static electricity e Hold components by the edges to avoid touching the ICs on them e Whenever you uninstall any component place it on a grounded antistatic pad or in the bag that came with the component e Before you install or remove any component ensure that the power supply is switched off or the power cord is detached from the power supply Failure to do so may cause severe damage to the motherboard peripherals and or components 2 2 Chapter 2 Hardware Information 2 2 Motherboard overview Before you install the motherboard study the configuration of your chassis to ensure that the motherboard fits into it To optimize the features of your motherboard we highly recommend that you install it in an SSI EEB 2
120. nctions when you enable the ASUS ASMB8 a Z10PE D16 Series 2 23 7 CATT LED CATTERRI The CATT LED indicates that the system has experienced a fatal or catastrophic error and cannot continue to operate ho Kaka h i d N oo ma F O Q j a py an Fan U 8F MO olin CATTERR1 Z10PE D16 Series CATTERR LED 8 Q Code LEDs LED1 The Q Code LED provides a 2 digit display that shows the status of your system Refer to the Q Code table of this user guide for more information about the 2 digit codes PAR AA TE ii oom Z10PE D16 Series Q_Code LED aa OS Ha LED1 Chapter 2 Hardware Information Q Code table Action PHA
121. nd Press Enter To Select An Option 2 When prompted use the arrow keys to select Yes from the Clear Configuration dialog box and then press lt Enter gt Easy Configuration Configuration Menu View Add Configuratio Initialize Clear Configuration eee Select Rebuild No Check Consistency Clear Existing Configuration Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option The utility clears all the current array s 3 Press any key to continue Z10PE D16 Series 5 21 5 2 7 Selecting the boot drive from a RAID set You must have created a new RAID configuration before you can select the boot drive from a RAID set See section 6 2 1 Creating a RAID set Using New Configuration for details To select the boot drive from a RAID set 1 From the Management Menu select Configure gt Select Boot Drive and then press lt Enter gt Configuration Menu Easy Configuration View Add Configuration Initialize Clear Configuration Objects Select Boot Drive Rebuild Check Consistency Select A Boot VD Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2 When prompted use the arrow keys to select the bootable virtual drive from the list then press lt Enter gt Configuri Boot VDs Current Boot VD 0 Easy Confi View Add Configuration Initialize Clear Configuration Objects Select Boot Drive Rebuild Check Consistency Select A Boot VD Use C
122. nep aeee intel Setup Is Complete You must restart this computer for the changes to take effect Would you like to restart the O No I will restart this computer later Click Finish then remove any installation media from the drives 6 26 Chapter 6 Driver Installation Appendix This appendix includes additional information that you may refer to when configuring the motherboard A 2 Z10PE D16 Series block diagram Z10PE D16 2L 10G 2T E5 2600v3 E5 2600v3 x16 Gen3 x16 Gen3 4x sSATA 3 6 x SATA 3 Intel RSTe RAID O 1 10 5 LSI MegaRAID O 1 10 x16 Gen3 x8 Gen3 PCIE6 x8 Gen2 x4 Gens PCIE3 X540 BT2 x2 Gen2 PCIE1 Appendix Z10PE D16 10G 2T x16 Gen3 PCIE4 x16 Gen3 PCIE2 Z10PE D16 Series E5 2600v3 E5 2600v3 QPI QPI DMI2 C612 PCH 4x sSATA 3 6 x SATA 3 Intel RSTe RAID O 1 10 5 LSI MegaRAID 0 1 10 x16 Gen3 m _ PCIE6 x8 Gens PCIE3 Ke Bana X540 BT2 x4 Gen3 PCIE1 x4 Gen2 x1 AST 2400 LPC A 3 A 4 Z10PE D16 4L x16 Gen3 x16 Gen3 E5 2600v3 E5 2600v3 16 Gen3 x PCIE6 8 Gens 2 PCIE3 x4 Gen2 1350 BT2 x2 Gen2 1350 AM2 4 Gen3 a rar x4 Gen2 4x sSATA 3 6 x SATA3 Intel RSTe RAID O 1 10 5 LSI MegaRAID 0 1 10 Appendix Z10PE D16 x16 Gen3 PCIE4 x16 Gen3 PCIE2 Z10PE D16 Series E5 2600v3 E5 2600v3 QPI 2 1 QPI DMI2 C612
123. ng reset Configuration options No Yes Next reset Yes Every reset When Log is Full Do Nothing Allows you to choose options for reactions to a full Smbios Event Log Configuration options Do Nothing Erase Immediately Chapter 4 BIOS Setup Smbios Event Log Standard Settings Log System Boot Event Disabled Allows you to choose options to enable disable logging of System boot event Configuration options Enabled Disabled MECI 1 Mutiple Event Count Increment MECI The number of occurrences of a duplicate event that must pass before the multiple event counter associated with the log entry is updated specified as a numeric value in the range 1 to 255 METW 60 Multiple Event Time Windows METW The number of minutes which must pass between duplicate log entries which utilize a multiple event counter The value ranges from 0 to 99 minutes Custom Option Log OEM Codes Enabled Enable or disable the logging of EFI Status Codes as OEM Codes if not already converted to legacy Configuration options Disabled Enabled Convert OEM Codes Disabled Enable or disable the converting of EFI Status Codes to Standard Smbios Types Not all may be translated Configuration options Disabled Enabled 4 7 2 View Smbios Event Log Press lt Enter gt to view all smbios event logs Z10PE D16 Series 4 41 4 42 4 8 Monitor menu The Monitor menu displays the system temperature power status and
124. ng with the last device on the chain c System power After applying power the system power LED on the system front panel case lights up For systems with ATX power supplies the system LED lights up when you press the ATX power button If your monitor complies with green standards or if it has a power standby feature the monitor LED may light up or switch between orange and green after the system LED turns on The system then runs the power on self test or POST While the tests are running the BIOS beeps or additional messages appear on the screen If you do not see anything within 30 seconds from the time you turned on the power the system may have failed a power on test Check the jumper settings and connections or call your retailer for assistance The following shows the possible beep codes and its corresponding error condition BIOS Beep codes Beep Error condition 1 short Power supply surges detected during the previous power on 1 short No Keyboard Detected 1 short 2 short No DIMM Detected 1 short 8 short No VGA Detected Chassis Intrusion BIOS image Crash Detected At power on hold down the lt Del gt key to enter the BIOS Setup Follow the instructions in Chapter 4 Chapter 3 Powering Up 3 2 Powering off the computer 3 2 1 Using the OS shut down function Using Windows Server 2008 R2 1 Click the Start button move the cursor to the triangle on the right of Log off then click Shut Down
125. onsistency Configure VD s Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option Chapter 5 RAID Configuration Menu Description Configure Allows you to create RAID 0 RAID 1 or RAID 10 set using the Easy Configuration or the New Configuration command This menu also allows you to view add or clear RAID configurations or select the boot drive Initialize Allows you to initialize the virtual drives of a created RAID set Allows you to initialize virtual drives or change the virtual drive parameters Rebuild Allows you to rebuild failed drives Check Consistency Allows you to check the data consistency of the virtual drives of a created RAID set 5 2 1 Creating a RAID set The LSI Software RAID Configuration Utility allows you to create a RAID 0 RAID 1 or RAID 10 set using two types of configurations Easy and New In Easy Configuration the virtual drive parameters are set automatically In New Configuration you manually set the virtual drive parameters Using Easy Configuration To create a RAID set using the Easy Configuration option 1 From the Management Menu select Configure gt Easy Configuration and then press lt Enter gt Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R Manager New Configuration View Add Configuration Initiali Clear Configuration Objects Select Boot Drive Rebuild Check Consistency Defines Physical Arrays An Arr
126. orage gt Intel Rapid Storage Console or click the Intel Rapid Storage Technology tray icon to load the Intel Rapid Storage Manager utility 6 From the View menu select Advanced Mode to display the details of the Intel Rapid Storage Console Te From the Volumes view option select RAID volume to view the rebuilding status When finished the status is changed to Normal Rebuilding the RAID with a new hard disk If any of the SATA hard disk drives included in the RAID array failed the system displays the status of the RAID volume as Degraded during POST You may replace the disk drive and rebuild the RAID array To rebuild the RAID with a new hard disk 1 Remove the failed SATA hard disk and install a new SATA hard disk of the same specification into the same SATA Port LN Select a destination disk with the same size as the original hard disk 2 Reboot the system then follow the steps in section Rebuilding the RAID with other non RAID disk Z10PE D16 Series 5 31 5 3 6 Setting the Boot array in the BIOS Setup Utility You can set the boot priority sequence in the BIOS for your RAID arrays when creating multi RAID using the Intel Rapid Storage Technology enterprise SATA Option ROM utililty To set the boot array in the BIOS BUN Set at least one of the arrays bootable to boot from the hard disk 1 Reboot the system and press lt Del gt to enter the BIOS setup utility during POST 2 Goto the Boot menu and s
127. osed key Example lt Enter gt means that you must press the Enter or Return key If you must press two or more keys simultaneously the key names are linked with a plus sign Example lt Ctrl gt lt Alt gt lt Del gt Means that you must type the command exactly as shown then supply the required item or value enclosed in brackets Example At DOS prompt type the command line format A S Z10PE D16 Series specifications summary Model Name Processor Support System Bus Core Logic Form Factor Expansion Slots follow SSI Location number Networking Z10PE D16 2L 10G 2T Z10PE D16 10G 2T 2 x Socket R3 201 1 Intel Xeon processor E5 2600 V3 product family QPI 6 4 8 0 9 6 GTps Intel C612 PCH SI EEB 12 in x 13 in 16 4 channels per CPU 2 DIMMs per CPU Maximum up to 1024 GB DDR4 2133 1866 1600 1333 RDIMM LR DIMM NVDIMM Refer to www asus com for latest memory AVI updates 4 GB 8 GB 16 GB 32 GB RDIMM 32 GB 64 GB LR DIMM 1 x PCI E x8 x4 Gen3 link MIO supported 1 x Dual port Intel X540BT2 10GbE LAN controller 1 x Dual port Intel X540BT2 1 x Dual port Intel1350 AM2 10GbE LAN controller Gigabit LAN controller 1 x Management port 1 x Management port continued on the next page Maximum at 2133 MT s at one DIMM per channel DCP only xiii XIV Z10PE D16 Series specifications summary Model Name Processor Support System Bus
128. process Z Write protect the floppy disk to avoid computer virus infection To create a RAID driver disk in Red Hat Enterprise Linux server environment 1 Insert a blank formatted high density floppy disk to the USB floppy disk drive 2 Typedd if XXX img of dev fd0 to decompress the file into the floppy disk from the following path in the support DVD For LSI MegaRAID Driver Drivers C610 LSI RAID Driver makedisk Linux 3 Eject the floppy disk Chapter 6 Driver Installation 6 1 2 Installing the RAID controller driver During Windows Server 2008 R2 OS installation To install the RAID controller driver when installing Windows Server 2008 R2 OS 1 Boot the computer using the Windows Server 2008 R2 OS installation disc Follow the screen instructions to start installing Windows Server 2008 R2 2 When prompted to choose a type of installation click Custom advanced GO 28 Install Windows Which type of installation do you want a Upgrade The option to Upgrade to a newer version of Windows and keep your files settings and programs upgrade is only available when an existing version of Windows is running We recommend backing up your files before you ceed proceed Custom advanced Install a new copy before you proceed y of Windows This option does not keep your files settings and programs The option to make changes to disks and partitions is available when you start your comp
129. pter 4 BIOS Setup 4 5 4 QPI Configuration QPI General Configuration QPI Status This item displays information about the QPI status Link Speed Mode Fast This item allows you to select the QPI link speed as either the fast mode or slow mode Configuration options Slow Fast Link Frequency Select Auto This item allows for selecting the QPI link frequency Configuration options Auto 6 4 GT s 8 0 GT s 9 6 GT s QPI LinkOp Enable Configuration options Disable Enable QPI Link1 Enable Configuration options Disable Enable Z10PE D16 Series 4 29 4 30 4 5 5 Memory Configuration Enforce POR Auto Allows you to enforce POR restrictions for DDR4 frequency and voltage programming Configuration options Auto Enforce POR Disabled Enforce Stretch Goals Memory Frequency Auto Allows you to select the memory frequency setting Configuration options Auto 1333 1600 1866 2133 Halt on mem Training Error Enabled Allows you to enable or disable halt on mem Training Error Configuration options Disabled Enabled ECC Support Auto Allows you to enable or disable the ECC support Configuration options Auto Disabled Enabled Data Scrambling Auto Allows you to enable disable data scrambling Configuration options Auto Disabled Enabled Enable ADR Disabled Allows you to set the detecting and enabling of ADR Configuration options Disabled Enabled C A
130. r OS through a serial port Configuration options None Hardware RTS CTS Software Xon Xoff Z10PE D16 Series 4 18 447 APM Allows you to configure the Advance Power Management APM settings Aptio Setup Utility Copyright C 2013 American Megatrends Inc Restore AC Power Loss Restore AC Power Loss Last State When set to Power Off the system goes into off state after an AC power loss When set to Power On the system will reboot after an AC power loss When set to Last State the system goes into either off or on state whatever the system state was before the AC power loss Configuration options Power Off Power On Last State Power On By PCle Disabled Disabled Disables the PCle devices to generate a wake event Enabled Enables the PCle devices to generate a wake event Power On By Ring Disabled Disabled Disables the PCle devices to generate a wake event Enabled Enables the PCle devices to generate a wake event Power On By RTC Disabled Disabled Disables RTC to generate a wake event Enabled When set to Enabled the items RTC Alarm Date Days and Hour Minute Second will become user configurable with set values Chapter 4 BIOS Setup 4 4 8 PCI Subsystem Settings Allows you to configure PCI PCI X and PCI Express Settings Aptio Setup Utility Copyright C 2013 American Megatrends Inc Load RT32 Image Load RT32 Image Enabled Allows you to enable or disabl
131. ration 6 Confirm the volume creation than click Create Volume to continue This process could take a while depending on the number and size of the disks You can continue using other applications during this time Create Volume 1 Select Confirm Volume Creation Review the selected configuration 2 Configure This process could take a while depending on the number and size of the disks You can continue using other applications during this time Back create Volume Cancel More help on this page 7 Wait until the process is completed then click OK when prompted Volume Creation Complete ox The volume was created successfully you still need to partition your new volume using Windows Disk Management before adding any data More help ox You still need to partition your new volume using Windows Disk Management before adding any data The RAID set is displayed in the Volumes list and you can change the settings in Volume Properties Ri Intel Rapid Storage Technology enterprise E lojx vd Current Status Your system is functioning normally amp ar poin S Array 00x 00 v amp Intel R C600 series chipset SAS RAID Controller Status Normal Type RAID 1 Change type Size 4 468 MB increase size System volume No Delete volume Write back cache Disabled Enable P Ged SAS disk 559 GB initialized No initialize D lt Ges sas
132. ring options for special functions Exit For selecting the exit options To select an item on the menu bar press the right or left arrow key on the keyboard until the desired item is highlighted Z10PE D16 Series 4 7 4 8 4 2 3 Menu items The highlighted item on the menu bar displays the specific items for that menu For example selecting Main shows the Main menu items The other items Event Logs Advanced Monitor Boot Tool and Exit on the menu bar have their respective menu items 4 2 4 Submenu items A solid triangle before each item on any menu screen means that the item has a submenu To display the submenu select the item then press lt Enter gt 4 2 5 Navigation keys At the bottom right corner of a menu screen are the navigation keys for the BIOS setup program Use the navigation keys to select items in the menu and change the settings 4 2 6 General help At the top right corner of the menu screen is a brief description of the selected item 4 2 7 Configuration fields These fields show the values for the menu items If an item is user configurable you can change the value of the field opposite the item You cannot select an item that is not user configurable A configurable field is enclosed in brackets and is highlighted when selected To change the value of a field select it and press lt Enter gt to display a list of options 4 2 8 Pop up window Select a menu item and press lt Enter gt to displ
133. ris ASUS Update ASUS Screen Saver Adobe Reader 105174538 Chapter 6 Driver Installation 6 3 3 MakeDisk menu tab The MakeDisk menu contains items to create the Intel RAID driver disks Make Disk Intel C610 series Chipset SATA sSATA A Please select items to install Intel C610 series ChipsetiSATA SSATATA Intel C610 series ChipsetiSATA sSATA A Intel C610 series ChipsetiSATA sSATATA Intel C610 series Chipset SATA sSATA A Intel C610 series Chipset SATA SSATATA 6 3 4 Manual menu The Manual menu provides the link to the Broadcom NetXtreme II Network Adapter user guide Broadcom NetXtreme Il Network Adapter Please select items to install Z10PE D16 Series 6 3 5 Contact information menu The Contact menu displays the ASUS contact information e mail addresses and useful links if you need more information or technical support for your motherboard Contact Address 15 Li Te Road Peitou Taipei Taiwan 11259 Telephone 886 2 2894 3447 Fax 886 2 2890 7798 Email info asus com tw Web site http Avww asus com tw Telephone 86 21 38429911 FAX 86 21 58668722 ext 9101 Online Support hitp Support asus com techservtechserv aspx Chapter 6 Driver Installation 6 4 Intel chipset device software installation This section provides the instructions on how to install the Intel chipset device software on the system You need to manually install the Intel chipset device sof
134. rtual Drive menu and then press lt Enter gt When creating a RAID 0 set proceed to step 12 11 Select On to enable the Disk Write Cache setting and then press lt Enter gt N Initial Objects Rebuild Check C Virtual Drive s Configured RAID Size Stripes StripSz 1 148 580GB 2 64KB Change DWC Virtual Drive 0 RAID 1 Ca Units MB Size 152146MB DWC OFF Disk Write Cache Setting of VD Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option Status ONLINE Enabling DWC can improve the performance but with the risk of data loss Chapter 5 RAID Configuration 12 When finished setting the selected virtual drive configuration select Accept from the menu and then press lt Enter gt Manage Configu Initial Objects Rebuild Check C Virtual Drive s Configured Size Stripes StripSz Status 148 580GB 2 64KB ONLINE Virtual Drive 0 RAID 1 Units MB 152146MB le 3 Accept This VD Configuration And Go To Next VD Cursor Keys SPACE De Select F2 ChIdInfo F3 SlotInfo F10 Configure Esc Quit 13 Follow step 2 to 12 to configure additional virtual drives 14 Press lt Esc gt to finish RAID configuration When prompted to save configuration select Yes from the menu and then press lt Enter gt Configuration Menu Easy Configuration Save Configuration Management Menu New Configuration View Add Configuration No Initialize Objects Reb
135. s Press lt Ctrl gt lt M gt to enter the utility LSI MegaRAID Software RAID BIOS Version A 10 09231523R LSI SATA RAID Found at PCI Bus No 00 Dev No 1F Device present at Port 0 ST3160812AS 152114MB Device present at Port 1 ST3160812AS 152114MB Device present at Port 2 T3160812AS 152114MB Device present at Port 3 T3160812AS 152114MB Press Ctrl M or Enter to run LSI Software RAID Setup Utility e The LSI MegaRAID software RAID configuration utility automatically configures to RAID 1 when the SATA to RAID Mode is enabled e The RAID setup screens shown in this section are for reference only and may not exactly match the items on your screen due to the controller version difference e When you create RAID sets with the LSI MegaRAID software RAID configuration utility the boot priority of the SATA optical drive has to be manually adjusted Otherwise the system will not boot from the connected SATA ODD 3 The utility main window appears Use the arrow keys to select an option from the Management Menu and then press lt Enter gt Refer to the Management Menu descriptions on the next page At the bottom of the screen is the legend box The keys on the legend box allow you to navigate through the setup menu options or execute commands The keys on the legend box vary according to the menu level LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R Initialize Objects Rebuild Check C
136. shes when data is read from Or written to the HDD 5 Power button soft off button 2 pin PWRSW This connector is for the system power button Pressing the power button turns the system on or puts the system in sleep or soft off mode depending on the BIOS settings Pressing the power switch for more than four seconds while the system is ON turns the system OFF 6 Reset button 2 pin RESET This 2 pin connector is for the chassis mounted reset button for system reboot without turning off the system power Z10PE D16 Series 2 41 14 Auxiliary panel connector 20 2 pin AUX_PANEL1 This connector is for additional front panel features including front panel SMB locator LED and switch and LAN LEDs n Hg h I2C 4 CLK iLK H HH mmm ae HH i f M tom UD Dar Z10PE D16 Series Auxiliarv panel connector Front panel SMB 10 2 pin FPSMB These connectors are for the front panel SMBus cable I2C 4 DATA AUX_PANEL1 CTelslslelslslels PIN 1 Saal es eg Le ee ae LAN activity LED 2 pin LAN1_LINKACTLED LA
137. slesl1 ga x86 64 img image linux doeS tmp O 4 Copy the contents of the image directory labeled as 01 into a FAT32 USB drive image File Browser File Edit View Go Bookmarks Tabs Help ae 7 S amp 8S R Back f Up t Reload Home Computer Search E tm image 02 m S SI Desktop 02 kal File System Network 5 Rename the 01 folder to CD Image Linux driver File Browser File Edit View Go Bookmarks Tabs Help e 7 amp S S8 8S R Back Forward Up t Reload Home Computer Search lt losenny 8007 Linux ariver Places v x fe asus cd image baal File System Ces Network 6 10 Chapter 6 Driver Installation Installing SUSE 11 Linux OS To install the LSI MegaRAID controller driver when installing SUSE Linux Enterprise Server OS 1 2 Boot the system from the SUSE OS installation CD Use the arrow keys to select Installation from the Boot Options menu CRE SUSE Linux Enterprise Server Boot from wail Installation Repair Installed System Rescue System Check Installation Media Firmware Test Memory Test Boot Options F1 Help F2 Language F3 Video Mode F4 Source F5 Kernel F6 Driver English US 800 x 600 DVD Default No Press lt F6 gt then select Yes from the menu Press Enter ce SUSE Linux Enterprise Server Boot from MP Installation Repair Installed System Rescue System Check Installation Media F
138. splays at the bottom of the screen 3 Follow step 3 to 12 of section 6 2 1 Creating a RAID set Using Easy Configuration to add a new RAID set Z10PE D16 Series 5 11 5 12 5 2 3 Initializing the virtual drives After creating the RAID set s you must initialize the virtual drives You may initialize the virtual drives of a RAID set s using the Initialize or Objects command on the Management Menu Using the Initialize command To initialize the virtual drive using the Initialize command 1 From the Management Menu select Initialize and then press lt Enter gt Management Menu Configure Objects Rebuild Check Consistency Initialize VD s Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option 2 The screen displays the available RAID set s and prompts you to select the virtual drive to initialize Use the arrow keys to select the virtual drive from the Virtual Drive selection and then press lt Space gt Virtual Drive s Configured RAID Size Stripes StripSz Status Management Menu contigure 1 148 580GB 2 64KB ONLINE Objects Rebuild Check Consistency Select VD SPACE De Select F10 Initialize Chapter 5 RAID Configuration 3 Press lt F10 gt to start initialization When prompted select Yes from the Initialize dialog box and then press lt Enter gt Virtual Drive s Configured RAID Size Stripes StripSz Management Menu Peng 1 148 580GB 2 64KB Obje
139. ssible Being a menu driven program it lets you scroll through the various sub menus and make your selections from the available options using the navigation keys aN e The default BIOS settings for this motherboard apply for most conditions to ensure optimum performance If the system becomes unstable after changing any BIOS settings load the default settings to ensure system compatibility and stability Press lt F5 gt and select Yes to load the BIOS default settings e The BIOS setup screens shown in this section are for reference purposes only and may not exactly match what you see on your screen e Visit the ASUS website www asus com to download the latest BIOS file for this motherboard Chapter 4 BIOS Setup 4 2 1 BIOS menu screen Menu items Menu bar Configuration fields General help Aptio Setup Utility Copyright C 2013 American Megatrends Inc System Language Navigation keys 4 2 2 Menu bar The menu bar on top of the screen has the following main items Main For changing the basic system configuration Advanced For changing the advanced system settings IntelRCSetup For changing the Intel RC settings Server Mgmt For changing the Server Mgmt settings Event Logs For changing the event log settings Monitor For displaying the system temperature power status and changing the fan settings Security For changing the security settings Boot For changing the system boot configuration Tool For configu
140. support DVD to the optical drive and find the utility menu 3 Click the Intel Rapid Storage Technology enterprise 4 0 to begin installation ASUS InstAll Installation Wizard fonUtili Please select items to install Intel Rapid StoragejTechnology enterpris ASUS Update ASUS Screen Saver Adobe Reader X10 174 38 4 When the Welcome to the Setup Program appears click Next to start the installation Welcome to the Setup Program qs This setup program will install Intel Rapid Storage Technology enterprise onto this computer Intel Rapid El TY ntel Itis strongly recommended that you exit all programs before continuing Click Next to continue Chapter 6 Driver Installation 5 Read the Warning message and click Next to continue Intel Rapid Storage TeeRnOlOgy ENTEN eee intel Warming The Intel Rapid Storage Technology enterprise driver you are about to install may be used to control the hard drive that this computer boots from or to control a hard drive that contains important data Therefore you will not be able to uninstall this driver after installation However you will be able to uninstall the non critical components of this software such as the User Interface Event Monitor Service and program shortcuts Click Next to continue or dick Cancel to exit the setup program Intel Installation Framework 6 Read the License Agreement and click Yes to continue Intel Rapid Storage TeeMNOlOgy ene
141. tement This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications This class B digital apparatus complies with Canadian ICES 003 REACH Complying with the REACH Registration Evaluation Authorization and Restriction of Chemicals regulatory framework we publish the chemical substances in our products at ASUS REACH website at http csr asus com english REACH htm Safety information Electrical safety To prevent electrical shock hazard disconnect the power cable from the electrical outlet before relocating the system When adding or removing devices to or from the system ensure that the power cables for the devices are unplugged before the signal cables are connected If possible disconnect all power cables from the existing system before you add a device Before connecting or removing signal cables from the motherboard ensure that all power cables are unplugged Seek professional assistance before using an adapter or extension cord These devices could interrupt the grounding circuit Make sure that your power supply is set to the correct voltage in your area If you are not sure about the voltage of the electrical outlet you are using contact your local power company If the power supply is broken do not try to fix it by yourself Contact a qualified service technician or your reta
142. tion ooooooo 4 12 4 4 4 Onboard LAN 1350 IO Configuration Z10PE D16 2L 10G 2T Z10PE D16 4L and Z10PE D16 4 13 4 4 5 Onboard LAN X540 IO Configuration Z10PE D16 2L 10G 2T and Z10PE D16 10G 2T oooooo 4 14 Contents 4 5 4 6 4 7 4 8 4 9 4 10 4 11 4 12 4 4 6 Serial Port Console Redirection ocooo oooom 4 15 4 4 7 AP Wises esse acta NN ests Tn Na an asda ties 4 18 4 4 8 PCI Subsystem Settings ooo oom 4 19 4 4 9 Network Stack Configuration ooooooWoWo 4 20 4 4 10 GSM GonfiguratiOn o denok bak matan man nan 4 21 4 4 11 Trusted ComputinG ea ah BNN aa 4 22 4 4 12 USB Configuration Leo Wonab uan ngk 4 23 4413 iSCSI Contigurationiis anakanak 4 24 Intel RC Setup Menu kanan 4 25 4 5 1 Processor ConligufatiO nenas naa 4 26 4 5 2 Advanced Power Management Configuration 4 28 4 5 3 Common RefCode Configuration o ooooooWoWo 4 28 4 5 4 OP F COMMGURAT OM aene cacti oie E E E 4 29 4 5 5 Memory Configuration ain ae uan akn 4 30 4 5 6 NOC OM An A N 4 32 4 5 7 POE COnnguralloncetsc sie RE BENER 4 33 4 5 8 Miscellaneous Configuration ooooooWoWo 4 35 4 5 9 Server ME Configuration oooooo oom 4 35 4 5 10 Runtime Error Logging Support oooooWooWooo 4 35 Server MME Menu aa sa mkn 4 36 Event LOGS Menu abhi 4 40 ATA Change Smbios Event Log Settings ooooooo
143. tion 2 6 Onboard LEDs 1 Standby Power LED SBPWR1 The motherboard comes with a standby power LED The green LED lights up to indicate that the system is ON in sleep mode or in soft off mode This is a reminder that you should shut down the system and unplug the power cable before removing or plugging in any motherboard component The illustration below shows the location of the onboard LED SBPWR1 Ll Ea ON OFF Standby Power Powered Off Z10PE D16 Series Standby Power LED 2 Baseboard Management Controller LED BMCLED1 The green heartbeat LED blinks per second to indicate that the ASMB8 is working normally h KA h i BMCLED1 on se nana ees Ger fio Z10PE D16 Series BMC LED Z The heartbeat LED functions only when you enable the ASUS ASMB8 _ Z10PE D16 Series 2 21 3
144. tware on a Windows operating system To install the Intel chipset device software 1 Restart the computer and then log on with Administrator privileges 2 Insert the motherboard system support DVD to the optical drive The support DVD automatically displays the Drivers menu if Autorun is enabled in your computer locate the file ASSETUP EXE from the BIN folder Double click the ASSETUP EXE to run Z If Autorun is NOT enabled in your computer browse the contents of the support DVD to A the support DVD 3 Click the item Intel Chipset Device Software from the menu ASUS InstAll Drivers Installation Wizard Please select items to instal Intel Chipset Device Software Intel 1350 AM4 1350 AM27 1210 X540 B1I ASPEED AST2300 AS2400 Display Dr Intel R C610 series Chipset SATATAHICI Intel C610 MEI NULL HEC Driver 4 The Intel Chipset Device Software window appears Click Next to start installation Intel Chipset Device Software intel Welcome to the Setup Program This setup program will install the Intel Chipset Device Software onto this computer It is strongly recommended that you exit all programs before continuing Z10PE D16 Series 6 17 D me Intel Chipset Device Software intel License Agreement You must accept all of the terms of the license agreement in order to continue the setup program Do you accept the terms INTEL SOFTWARE LICENSE AGREEMENT OEM IHV ISV Distribution amp
145. twork Connections InstallShield Wizard window appears Welcome to the install wizard for Intel R Network Connections Installs drivers Intel R Network Connections and Advanced Networking Services WARNING This program is protected by copyright law and international treaties 7 pena cated Please read the following license agreement carefully INTEL SOFTWARE LICENSE AGREEMENT IMPORTANT READ BEFORE COPYING INSTALLING OR USING Do not copy install or use this software and any associated materials collectively the Software provided under this license agreement Agreement until you have carefully read the following terms and conditions By copying installing or otherwise using the Software you agree to be bound by the terms of this Agreement If you do not agree to the terms of this Agreement J dn wnt nnm inntinii ne nn tha Canfhunen I do not accept the terms in the license agreement 8 From the Setup Options window click Next to start the installation By default Intel R PROSet for Windows Device Manager and Windows PowerShell Module are ticked Setup Options Select the program features you want installed Install V Drivers WJ Intel R PROSet for Windows Device Manager in W Advanced Network Services e JFCOE using Data Center Bridging e JiSCSI using Data Center Bridging of Windows PowerShell Module L JIntel
146. ue the installation Toggle Yes want to restart the computer npw and click Finish to complete the Chapter 6 Driver Installation 6 5 Installing the Intel 1350 AM1 1350 AM2 1210 X540 BT2 Gigabit Adapters driver This section provides the instructions on how to install the Intel 1350 AM1 1350 AM2 1210 X540 BT2 Gigabits Adapter Driver on the system To install the Intel I350 AM1 1350 AM2 1210 X540 BT2 Gigabit Adapters Driver on the Windows operating system 1 Restart the computer 2 Logonwith Administrator privileges 3 Insert the motherboard system support DVD to the optical drive Z If Autorun is NOT enabled in your computer browse the contents of the support DVD to locate the file ASSETUP EXE from the BIN folder Double click the ASSETUP EXE to run i the support DVD 4 Click Intel 1350 AM1 1350 AM2 I210 X540 BT2 Gigabit Adapters Drivers in the Drivers menu of the main screen to start the installation ASUS InstAll Drivers Installation Wizard Install 1350 AM4 1350 AM2 1210 x540 BT2 10G Gigabit Adapters Driver Intel Chipset Device Software Intel 1350 AM4 13507AM27 1210 X540 B1T 2 Gigabit Adapters Driver AO LLUV AOI CJUU AJI CL RUU WI PIOyj WI Intel R C610 series Chipset SATAYAHGIIN Intel C610 MEI NULL HECI Driver 5 Click Install Drivers and Software option to begin installation Intel Network Connections intel Z10PE D16 Series 6 19 6 Click Next when the Intel R Ne
147. ui Z10PE D16 Series Clear Configuration Select Boot Drive Virtual Drive s Configured RAID Size Stripes StripSz Status 1 148 580GB 2 64KB ONLINE Select Yes Or No Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 5 9 Using New Configuration When a RAID set already exists using the New Configuration command erases the 5 existing RAID configuration data If you do not want to delete the existing RAID set use the View Add Configuration command to view or create another RAID configuration To create a RAID set using the New Configuration option 1 From the Management Menu select Configure gt New Configuration and then press lt Enter gt Configuration Menu Easy Configuration Management Me View Add Configuration Initialize Clear Configuration Objects Select Boot Drive Rebuild Check Consistency Clear Existing Configuration And Start A New Configuration Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2 Follow step 2 to 9 of the previous section Using Easy Configuration 3 Select Size from the Virtual Drive menu and then press Enter 4 Key in the desired virtual drive size and then press Enter Virtual Drive s Configured Size Stripes StripSz Status 148 580GB 2 64KB ONLINE Initial Objects Rebuild Check C Enter VD Size 152146 DWC OFF RA On Accept SPAN NO Enter VD Size Use Cursor Keys To
148. uration options Enabled Disabled Auto XHCI Hand off Enabled This is a workaround for OSes without XHCI hand off support The XHCI ownership change should be claimed by XHCI driver Configuration options Disabled Enabled EHCI Hand off Disabled This is a workaround for OSes without EHCI hand off support The EHCI ownership change should be claimed by EHCI driver Configuration options Disabled Enabled USB Mass Storage Driver Support Enabled Allows you to enable or disable the USB Mass Storage drvier support Configuration options Disabled Enabled Port 60 64 Emulation Enabled This allows you to enable the I O port 60h 64h emulation support This should be enabled for the complete USB keyboard legacy support for non USB aware OSes Configuration options Disabled Enabled Z10PE D16 Series 4 23 USB hardware delays and time outs USB transfer time out 20 sec The time out value for control bulk and interrupt transfer Configuration options 1 sec 5 sec 10 sec 20 sec Device reset time out 20 sec USB mass storage device start unit command time out Configuration options 10 sec 20 sec 30 sec 40 sec Device power up delay Auto This is the maximum time the device will take before it properly reports itself to the host controller Configuration options Auto Manual Mass Storage Devices Generic 8 07 Auto Allows you to select the mass storage device emulation type
149. ursor Keys To Navigate Between Items And Press Enter To Select An Option 3 The virtual drive is selected as boot drive Press any key to continue 5 22 Chapter 5 RAID Configuration 5 2 8 Enabling WriteCache You may manually enable the RAID controller s WriteCache option after creating a RAID set to improve the data transmission performance A When you enable WriteCache you may lose data when a power interruption occurs while transmitting or exchanging data among the drives The WriteCache function is recommended for RAID 1 and RAID 10 sets To enable WriteCache 1 From the Management Menu select Objects gt Adapter select an existing adapter and then press lt Enter gt to display the adapter properties 2 Select Disk WC and then press lt Enter gt to turn on the option LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R Objects Virtual Drive Management Configure Initialize Objects Rebuild Check Consistency Rebuild Rate 30 Chk Const Rate 30 FGI BGI Read Bios Cont Fast Auto Auto Disk Rate Rate Physical Driv Di sk WC Off 30 30 Ahead State On Error Init Rebuild Resume Coercion Enable On Enable 1GB Factory Default Disk Write Cache Off Write Through or On Write Back Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 3 From the Management Menu select Objects gt Virtu
150. uter using the installation disc We recommend backing up your files Help me decide 3 Click Load Driver n E 24 Install Windows Where do you want to install Windows Name Total Size Free Space Type Disk 0 Partition 1 1534 GB Disk 1 Unallocated Space 148 1 GB 144 1 GB System 148 1 GB Z10PE D16 Series A message appears reminding you to insert the installation media containing the driver of the RAID controller driver If you have only one optical drive installed in your system eject the Windows OS installation disc and replace with the motherboard Support DVD into the optical drive Click Browse to continue Load Driver lee To install the device driver needed to access your hard drive insert the installation media containing the driver files and then click OK Note The installation media can be afloppy disk CD DVD or USB flash drive Browse DX Cancel Locate the driver in the corresponding folder of the Support DVD then click OK to continue Select the RAID controller driver you need from the list and click Next When the system finishes loading the RAID driver replace the motherboard Support DVD with the Windows Server installation disc Select the drive to install Windows and click Next E 24 Install Windows Where do you want to install Windows Disk 0 Partition 1 153 4 GB 1440 GB System
151. veloped by Intel R There are some restrictions on how these products may be used and what information may be disclosed to Z10PE D16 Series 6 25 8 After completing the installation click Next to complete the setup process Intel Rapid El AAN intel Setup Progress Please wait while the following setup operations are performed Copying File C Program Files x86 Intel Intel R Rapid Storage Technology enterpriselzh TV a Copying File C Program Files x86 Intel Intel R Rapid Storage Technology enterprise zh TV Copying File C Program Files x86 Untel Untel R Rapid Storage Technology enterprise lzh TV Copying File C Program Files x86 Untel Untel R Rapid Storage Technology enterprise zh TV Copying File C Program Files x86 Intel Intel R Rapid Storage Technology enterprise lzh TV Copying File C Program Files x86 Untel Untel R Rapid Storage Technology enterprise lzh TV Creating Process C Windows Microsoft NET Framework v4 0 30319 installutil exe Creating Process C Windows Microsoft NET Framework v4 0 30319 ngen exe Creating Registry Key HKLM System CurrentControlSet Services laStorDataMgrSvc Delayed Creating Registry Key HKLM SOFTWARE Microsoft Windows CurrentVersion Run IAStorIcon Click Next to continue lt il 9 Select Yes want to restart my computer now and click Finish to restart your computer before using the program Intel Rapid Storage TeeMMOlOay e
152. ver mount dev fd0 mnt driver cd mnt driver sh replace_ahci sh reboot Chapter 6 Driver Installation Red Hat Enterprise Linux OS 6 x To install the LSI MegaRAID controller driver when installing Red Hat Enterprise OS 1 Boot the system from the Red Hat OS installation CD 2 Press lt Tab gt to edit options Welcome to Red Hat Enterprise Linux 6 1 Install or upgrade an existing system Install system with basic video driver Rescue installed system Boot from local drive Memory test Press Tab to edit options 3 While booting from DVD press lt ESC gt to give the third party driver Enter the following command at the boot Linux dd blacklist isci blacklist ahci nodmraid then press lt ENTER gt Welcome to Red Hat Enterprise Linux 6 1 Install or upgrade an existing system Install system with basic video driver Rescue installed system Boot from local drive Memory test unlinuz initrd linux dd blacklist isci blacklist ahci nodmraid_ RED HAT ENTERPRISE LINUX 6 Copyright 2003 2010 Red Hat Inc and others All rights reserved Z10PE D16 Series 4 Select Yes using the Tab key when asked if you have the driver disk then press Enter Main Menu Do you have a driver disk You have multiple devices which could serve as source for a driver disk Choose one you like to use and select OK then press lt Enter gt Driver Disk Sou8rce You have multiple devices which
153. y by BIOS or BMC Configuration options Previous State Static Dynamic Obtained by BMC running DHCP Z The following items appear only when you set IP BMC Lan IP Address Source to Static IPv6 BMC LAN IP Address Allows you to input IPv6 BMC Lan IP address IPv6 BMC LAN IP Prefix Length Allows you to input IPv6 BMC Lan IP Prefix Length IPv6 BMC LAN Default Gateway Allows you to input IPv6 BMC Lan Default Gateway IPv6 BMC LAN DNS Settings Allows you to enter IPv6 BMC LAN DNS Settings IPv6 BMC LAN Link IP Address Allows you to enter IPv6 BMC LAN Link IP address IPv6 BMC LAN Link IP Prefix Length Allows you to input IPv6 BMC Lan Link IP Prefix Length Z10PE D16 Series 4 39 4 40 4 7 Event Logs menu The Event Logs menu items allow you to change the event log settings and view the system event logs Aptio Setup Utility Copyright C 2013 American Megatrends Inc b Change Smbios Event Log Settings 4 7 1 Change Smbios Event Log Settings Press lt Enter gt to change the Smbios Event Log configuration Z All values changed here do not take effect until computer is restarted Enabling Disabling Options Smbios Event Log Enabled Change this to enable or disable all features of Smbios Event Logging during boot Configuration options Disabled Enabled Erasing Settings Erase Event Log No Choose options for erasing Smbios Event Log Erasing is done prior to any logging activation duri