Home
OPTI VS375C uninterruptible power supply (UPS)
Contents
1. 2 2 Power On Off Test Silence Button The On Off Test Silence Button has four functions 1 When the UPS is off and AC power is present press this button for more than 3 seconds to turn on the UPS The UPS can be turned on even when AC power is not present 2 When the UPS is on press this button for more than 3 seconds to turn off the UPS and output power 3 When UPS is j mode function is when the UPS has a LOW BATTERY or OVERLOAD 4 Quickly press perform button while the UPS is under AC mode and the UPS will self test procedure No load shut down function the UPS will automatically turn off if none of the connected is Once normal utility power the unit 2 3 Status Indication UPS Status Indication Front Panel LED 8 VS375C VS575C cc 2 4 2 5 2 6 2 7 When this Green LED is lit the UPS is in normal mode AC Mode and providing power to your equipment The UPS will continue to filter and provide surge protection When this Yellow LED is lit the UPS is providing power Battery Mode from its battery Also this LED is lit when you press the button to test the battery This Red LED indicator indicates two statuses of the UPS When this Red LED is on it indicates that the battery needs to be replaced When this Red LED is flashing rapidly it indicates the UPS is over loaded Battery Fault Communication Port Remote Por
2. 17 VS375C VS575C i A MMM aMi 6 2 Battery Replacement Procedure for VS375C VS575C SES gt a n PLE PERTENECE r r gt T Sfoo7nen eroicoooe Pieooenan E etpoeeoo TATARER ft poso Da Seoopacg fe pi ipenan iP a i r F Broaoe Soba 550000 CNE doc Gi con Sono nasa A E AL Li DANA Z Changing the batteries in your UPS is a safe and easy procedure Since the battery is isolated from the AC input you may leave your UPS and computer or other equipment on during the following procedure Please note that if you choose to leave the UPS on when the battery is removed it will not be able to power your equipment if a power failure occurs Please read the cautions in section 6 1 before performing the following steps OB NS OND Remove the two small screws from the side of the UPS plastic case Gently slide the battery plate off Gently pull out the battery Disconnect the two wires connecting the battery to the UPS Connect the wires to the new battery making sure that the red wire is connected to the red battery terminal and the black wire is connected to the black battery terminal Push the new battery into place Reposition the battery retaining plate Tighten the two small screws on the bottom of the UPS plastic case 18 i A VS375C VS575C e a Fuse Replacement Procedure a Wes E E INE E
3. SS da nko E a O gt Li Use a slotted screwdriver to take out the fuse socket Take out the broken fuse from the fuse socket Throw away the broken fuse Use the slotted screwdriver to push out the spare fuse Put the spare fuse into the fuse socket Push the fuse socket into the AC input socket
4. 6 USER REPLACEABLE BATTERY The Batteries inside your UPS should last from between 3 to 5 years If you suspect that the batteries are weak allow the UPS to charge the batteries for at least six hours and then test the backup time If the UPS still does not provide adequate backup time follow the procedures below to replace the batteries Please read section 6 1 before performing the procedure in sections 6 2 6 1 Warning Servicing of batteries should always be performed or supervised by personnel knowledgeable of batteries and required precautions Please read the following cautions before replacing the batteries Keep unknowledgeable i e unauthorized personnel away from the batteries CAUTION Except for the battery the unit contains no user serviceable parts Repairs should be performed only by factory trained service personnel CAUTION A battery can present a risk of electrical shock and high short circuit current The following precautions should be observed when working on batteries 1 Remove watches rings or other metal objects 2 Use tools with insulated handles CAUTION Do not dispose of batteries in a fire The batteries may explode CAUTION Do not open or mutilate batteries They contain an electrolyte which is toxic and harmful to the skin and eyes CAUTION When replacing batteries use the same number and the following type batteries sealed Lead Acid Maintenance Free VS375C 1x 12V3 5AH VS575C 1 x 12V 3 8AH
5. HOCK BURNS FROM HIGH SHORT CIRCUIT CURRENT FIRE OR EXPLOSION FROM VENTED GASES OBSERVE PROPER PRECAUTIONS WHEN REPLACING BATTERIES USE THE SAME NUMBER AND THE FOLLOWING TYPE BATTERIES SEALED LEAD ACID MAINTENANCE FREE VS375C 1 X 3 5AH 12V VS575C 1 X 3 8AH 12V PROPER DISPOSAL OF BATTERIES IS REQUIRED REFER TO YOUR LOCAL CODES FOR DISPOSAL REQUIREMENTS 2 Wa TEA A A VS375C VS575C CAUTION A A THE UPS CONTAINS VOLTAGES WHICH ARE POTENTIALLY HAZARDOUS ALL REPAIRS SHOULD BE PERFORMED BY QUALIFIED SERVICE PERSONNEL THE UPS HAS ITS OWN INTERNAL ENERGY SOURCE BATTERY THE OUTPUT RECEPTACLES MAY BE LIVE EVEN WHEN THE UPS IS NOT CONNECTED TO AN AC SUPPLY Safe and continuous operation of the UPS depends partially on the care taken by users Please observe the following precautions Do not disassemble the UPS Do not attempt to power the UPS from any receptacle except a 2 pole 3 wire grounded receptacle Do not place the UPS near water or in environments of excessive humidity Do not allow liquid or any foreign objects to get inside the UPS Do not block air vents on the side of the UPS Do not plug appliances such as hair dryers into the UPS receptacles Do not place the UPS under direct sunshine or close to heat emitting sources This UPS is intended for installation in a temperature controlled indoor area free of conductive contaminants The socket outlet shall be installed near the UPS and ea
6. Output Outlet INSTALLATION AND OPERATION 3 1 Unpacking and Inspection 3 2 Placement 3 3 Determining How Much Equipment You Can Connect to Your UPS 3 4 Powering Up Your UPS 3 5 Connecting Your Equipment to the UPS 3 6 Operation and Function Test 3 7 Storage Instructions SPECIFICATIONS 4 1 Electrical Specifications 4 2 Mechanical Specifications 4 3 Environmental Specifications TROUBLESHOOTING 5 1 Troubleshooting Chart USER REPLACEABLE BATTERY 6 1 Warning 6 2 Battery Replacement Procedure for 500VS II OOo 00 00 00 00 00 Y Y 13 14 14 15 16 17 VS375C VS575C 5 A a aM 1 1 1 1 2 1 3 AC SOURCE INTRODUCTION Overview The Value Series of Uninterruptible Power Systems UPS was designed to prevent spikes transients and blackouts from reaching your sensitive equipment Your equipment may include such items as computers and computerized instruments to telecommunication systems When AC power is present the UPS filters the power continuously When AC power fails the unit employs its internal maintenance free battery to supply back up power without interruption EMI RFI TRANSFER NOISE FILTER SWITCH TO LOAD i e your equipment MICROPROCESSOR DC AC INVERTER Value Series Features Frequency Auto Sensing The VS models can operate in either a 50 or 60 Hz environment When you plug the UPS into an AC outlet and turn it on it will automatically d
7. User Guide Value Series Model VS375C VS575C For your records The serial number of your UPS is on the rear panel You should note the serial number in the space provided below Retain this booklet as a permanent record of your purchase to aid in identification in the event of theft or loss Model No Serial No Purchase Date LIMITED WARRANTY What the warranty covers We warrant this product to be free from defects in material and workmanship during the warranty period If a product proves to be defective in material or workmanship during the warranty period we will at our sole option repair or replace the product with a like product How long the warranty is effective For accurate warranty period and conditions please contact local branch offices or your dealers Who the warranty protects This warranty is valid only for the first consumer purchaser What the warranty does not cover 1 Any product on which the serial number has been defaced modified or removed 2 Damage deterioration or malfunction resulting from a Accident misuse neglect fire water or other acts of nature unauthorized product modification or failure to follow instructions supplied with the product b Repair or attempted repair by anyone not authorized c The fault is result of accidental damage or damage in transit or transportation including but not limited to liquid spillage d Removal or installation of the product e Causes ex
8. V 120 134 138V 220 230 240V 165 184 192V 275 276 276V Input Output Frequency Range 50 Hz 60 Hz 10 Output Inverter mode 50 Hz 60 Hz 0 3 Hz Wave Form AC Mode Back Up Mode Transfer Time Power failure AC inverter 4 ms typical Spike Surge Protection Version Continuous Single pulse 8 20us Voltage Vrms 100 110 120 175V 6500A 1050 220 230 240 300V 6500A 1050 Data Line Surge Suppression E 6KV Peak Telephone Line Surge Protection 1 2uS 50 Waveform 10 100 Base T Protection Let lt 1 Through Rating From 6KV 125A Normal Mode Surge 14 VS375C VS575C A A A Audible Alarm Battery discharge at power failure Beep every 4 seconds Battery approaches final discharge Beep every second 4 2 Mechanical Specifications ProductName Dimensions Weight Kg Pp WxDxH mm Net Gross 20077175 20077175 4 3 Environmental Specifications AA Operating Storage and Shipment 0 40 C 32 104 F 20 60 4 140 F 5 90 non condensing 5 90 non condensing Altitude 3 000 m 10 000 ff Max 12 000 m 40 000 ff Max VS375C VS575C AAA a M a 5 TROUBLESHOOTING If the UPS fails to operate properly please review the following steps before calling the repair center 1 Is the UPS plugged into a proper working outlet 2 Is the line voltage within the rating specified 3 Does the circuit breaker on the rear panel need to be r
9. eset 5 1 Troubleshooting Chart Problem Possible Cause Corrective Action UPS can not turn on and has no alarm Battery LED amber is lit and UPS beeps every 4 seconds The UPS Overload LED red is always lit amp there is a continuous sounding alarm The UPS Battery Weak LED red is always lit Backup time is less than the rating UPS appears to be UPS switch pressed front panel on off has not been Press the On Off switch for two seconds Load less than 20W at battery mode Normal condition No load shutdown function is active Battery voltage less than 10V Recharge the UPS for at least 6 hours PCB failure voltage UPS input power cord is not plugged in AC Fuse burned out UPS is overloaded Battery voltage too low Dead battery Battery is not fully charged or battery is dead Contact dealer or OPTI UPS service Normal condition Plug in input power cord Replace the AC fuse Remove the least critical devices from the load Recharge the battery and reset Plug the UPS into an AC outlet and recharge the battery for 6 hours If problem remains replace the battery functioning normally Computer input power cord Check the computer input but the computer won t turn on Software communication working is loose or not connected power cord t Wrong interface cable Purchase the correct one from your distributor 16 VS375C VS575C A e
10. etect the incoming line frequency and configure itself to match that frequency User Replaceable Battery Design The battery is the most critical part in a UPS The average lifetime of a battery is between 3 and 5 years The special user replaceable battery design of this UPS provides significant savings and gives the UPS an almost unlimited life You can replace the battery very easily and without turning off your UPS or the equipment it is protecting Many UPS s provide only a basic power failure warning The Value Series together with OPTI SAFE Xtreme also provides you with important operating information If OPTI SAFE Xtreme is not part of your UPS package you can purchase it from your local dealer 6 VS375C VS575C A A A 1 4 Over Voltage and Under Voltage Protection The UPS will switch to backup mode and provide the power from its internal battery when the input line voltage is too low or too high 1 5 Schedule Shutdown amp Startup Using OPTI SAFE Xtreme you can locally or remotely control the shutdown and startup of equipment connected to a UPS A customized schedule can be developed to meet your specific requirements 1 6 Data Line Surge Protection The built in data line surge suppression on the rear panel completes your system protection lt provides an easy way to protect a network RJ45 or modem single line phone connection from hazardous spikes VS375C VS575C 7 A a aMi 2 UPS CONTROLS 2 1 External Views
11. he packing carton for damage and accessory in the box Notify the carrier immediately if damage is observed UPS 1 User Manual 1 Power Cord 1 CD ROM 1 Communication Cable 1 Telephone Line 1 save the box 3 2 Placement 1 This unit is intended for indoor use only Although your UPS is very rugged its internal components are not sealed from the environment 2 The UPS must be installed in a protected environment away from heat emitting appliances such as heaters or radiators Do not install this product where excessive moisture is present e E J X X X 3 The location should provide adequate air flow around the UPS with one inch minimum clearance on all sides for proper ventilation 3 3 Determining How Much Equipment You Can Connect to Your UPS 1 Make a list of all equipment that requires protection 2 Each piece of equipment has voltage and current VA ratings printed on the back label see examples below Your equipment may have a voltage rating such as 88 264V If you live in the United States you should use 120V in your calculations since the standard voltage in the United States is 120V 10 VS375C VS575C A A A o ViewSonic G810 Computer Co 120V 2 74 Pentium Pro 200MHz 50 60 Hz 120V 2 04 SN Q771515388 50 60 Hz SN 123456 3 Multiply the voltage and current of each piece of equipment VA requirements for example 120V x 2 7A 324VA 120V x 2 0A 240VA Add up the VA requirement
12. l Normal Mode LED will light 2 The UPS may be overloaded if the UPS buzzer sounds continuously and the Battery Fault LED flashes Unplug the least critical devices such as a printer etc If the buzzer is still sounding the battery or UPS may be faulty Contact your local dealer for assistance 12 VS375C VS575C A A Note Backup all unsaved files before you perform the following functional test 3 To test the backup function you may unplug the power cord of the UPS During this test observe that your equipment operates properly and without interruption If you leave your UPS on continuously it is a good idea to perform a backup function test at least once a month 4 If you unplug the power cord all models will beep once every 4 seconds and the Battery Mode LED will light You can press the Test Silence Button to silence the alarm Plug the power cord back in after a few seconds 3 7 Storage Instructions For extended storage in moderate climates the battery should be charged for 12 hours every 3 months Repeat it every 2 months in high temperature locations Plug in the power cord to charge the battery VS375C VS575C 13 AAA a a G d 4 SPECIFICATIONS 4 1 Electrical Specifications Frequency Hz Voltage V Capacity VA W 100 110 120 VS375C 50 60 375VA 225W 220 230 240 100 110 120 VS575C 50 60 220 230 240 575VA 345W Input Output Voltage AC Line Voltage Upper Limit 100 110 120V 85 94 102
13. s for all the devices for example 324VA 240VA 564VA 4 Make sure that your UPS has at least as much VA capacity as your equipment requires 3 4 Powering Up Your UPS 1 For 100 110V 120V versions connect the power cord to a grounded 3 wire receptacle For 220V 230V 240V versions please refer to Sec 3 5 NY A 2 Power up the UPS by pressing the On Off switch on the front panel for three seconds 3 We recommend that you charge the battery for six 6 hours before first use of your UPS You may use the UPS immediately without charging the battery but the backup time may be less than the rating The UPS recharges the battery automatically whenever AC power is available VS375C VS575C 11 A a aM 3 5 Connecting Your Equipment to the UPS 1 For all UPS models except the 2x0V versions connect the power cord s of your computer equipment to the output receptacle s of the UPS Switch on the computer equipment 2 For 2x0V versions as shown in the illustration below connect the input power cord of your computer equipment to the inlet of the UPS and the wall socket Use the power cord supplied with the UPS to connect from the outlet of the UPS to your equipment Switch on the computer 3 DO NOT PLUG LASER PRINTERS INTO THE UPS BECAUSE THEY TYPICALLY DRAW TOO MUCH POWER z Ta eal gutia ean Cannot pul of he PC te UPS 3 6 Operation and Function Test 1 Connect the input power and turn on the UPS The front pane
14. sily accessible With the installation of the UPS it should be prevented that the sum of the leakage current of the UPS and the connected consumer exceeds 3 5mA The battery supply should be disconnected in the plus and minus pole at the quick connectors of the battery when maintenance or service work inside the UPS is necessary Do not dispose of batteries in a fire The battery may explode Do not open or mutilate the battery or batteries released electrolyte is harmful to the skin and eyes A battery can present a risk of electric shock and high short circuit current The following precaution should be observed when working on batteries Remove watches rings or other metal objects Use tools with insulated handles To reduce the risk of fire connect only to a circuit provided with 20 amperes maximum branch circuit overcurrent protection in accordance with the National Electrical Code ANSI NFPA 70 VS375C VS575C 3 A MMM aM 8L FEDERAL COMMUNICATIONS COMMISSION FCC WARNING This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Howe
15. t This port allows for a computer to monitor the status and control the operation of the UPS Its functions include the following To broadcast a warning when power fails To close any open files before the battery reserves are exhausted To turn off the UPS Note that software and the communication cable are only available in certain areas Contact your local dealer for more information Data Line Surge Protection In amp Out The data line surge protection on the rear panel provides an easy way to protect a network RJ45 or modem RJ11 connection from hazardous spikes Connect a network cable or a single line telephone into the In socket To complete the connection connect another network cable or telephone line into the Out socket AC Input Connect the AC power cord into the AC Input socket UPS can have power from commercial electricity lt has a fuse in the socket to protect over current The spare fuse also inside the socket for replacing Output outlet There are two kinds function output outlets 1 Bypass These output outlets offer surge protection only It won t have back up power at inverter mode 2 UPS outlet These output outlets not only offer surge protection but also back up power to your main equipments at inverter mode VS375C VS575C 9 e A 3 INSTALLATION AND OPERATION Before installation please read and understand the following instructions 3 1 Unpacking and Inspection Examine t
16. tations of Warranty for Australian States and Territories The Trade Practices Act 1974 and corresponding State and Territory Fair Trading Acts or legalization of another Government the relevant acts in certain circumstances imply mandatory conditions and warranties which cannot be excluded This warranty is in addition to and not in replacement for such conditions and warranties To the extent permitted by the Relevant Acts in relation to your product and any other materials provided with the product the Goods the liability of Opti Australia under the Relevant Acts is limited at the option of Opti Australia to Replacement of the Goods or Repair of the Goods or Payment of the cost of replacing the Goods or Payment of the cost of having the Goods repaired Opti Australia reserves the right to request proof of purchase upon any warranty claim Life Support We do not recommend the use of our UPS products for life support equipment or direct care where failure of a UPS product could cause failure of or diminished effectiveness of the life support equipment or patient care Except as expressly provided for by the UPS Equipment Protection Policy EFFECTIVE October 1 1997 VS375C VS575C 1 A MMM aM iLL IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS A A THIS MANUAL CONTAINS IMPORTANT SAFETY INSTRUCTIONS KEEP THIS MANUAL HANDY FOR REFERENCE CAUTION A BATTERY CAN PRESENT A RISK OF ELECTRICAL S
17. ternal to the product f Use of supplies or parts not meeting our specifications g Normal wear and tear h Any other cause which does not relate to a product defect 3 Removal installation and set up service charges Limitation of implied warranties THERE ARE NO WARRANTIES EXPRESS OR IMPLIED WHICH EXTEND BEYOND THE DESCRIPTION CONTAINED HEREIN INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Exclusion of damages OUR LIABILITY IS LIMITED TO THE COST OF REPAIR OR REPLACEMENT OF THE PRODUCT WE SHALL NOT BE LIABLE FOR 1 DAMAGE TO OTHER PROPERTY CAUSED BY ANY DEFECTS IN THE PRODUCT DAMAGES BASED UPON INCONVENIENCE LOSS OF USE OF THE PRODUCT LOSS OF TIME LOSS OF PROFITS LOSS OF BUSINESS OPPORTUNITY LOSS OF GOODWILL LOSS OF DATA LOSS OF SOFTWARE COSTS OF SUBSTITUTE EQUIPMENT INTERFERENCE WITH BUSINESS RELATIONSHIPS CLAIMS BY THIRD PARTIES OR OTHER COMMERCIAL LOSS EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES 2 ANY OTHER DAMAGES WHETHER INCIDENTAL CONSEQUENTIAL OR OTHERWISE 3 ANY CLAIM AGAINST THE CUSTOMER BY ANY OTHER PARTY Effect of state law for US This warranty gives you specific legal rights and you may also have other rights which vary from state to state Some states do not allow limitations on implied warranties and or do not allow the exclusion of incidental or consequential damages so the above limitations and exclusions may not apply to you Limi
18. ver there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and the receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help CANADIAN DEPARTMENT OF COMMUNICATIONS DOC This equipment does not exceed Class B limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications Operation in a residential area may cause Unacceptable interference to radio and TV reception requiring the owner or operator to take whatever steps are necessary to correct the interference 4 1 VS375C VS575C A A A TABLE OF CONTENTS INTRODUCTION 1 1 Overview 1 2 Frequency Auto Selection 1 3 User Replaceable Battery Design 1 4 Over Voltage and Under Voltage Protection 15 Schedule Shutdown amp Startup 1 6 Data Line Surge Protection UPS CONTROLS 2 1 External Views 22 Power On Off Button 2 3 Status Indicators 2 4 Communication Port 2 5 Data Line Surge Protection 2 6 AC Input 2 7
Download Pdf Manuals
Related Search
Related Contents
Samsung Home Audio WAM7501 Manual de Usuario HP 15 15-g035wm Télécharger l`extrait au format PDF 簡易取扱説明書 CATA SCIENCE/MARINE 2005 FOLDOVER RAMP Low-Floor Vehicle Access Ramp GILLIG NEC Display Wall Calibrator User's Guide Wells WV-FG SERIES Specifications Manual/Parts MasterTop 200 PG Copyright © All rights reserved.
Failed to retrieve file