Home

Lindy 39524 KVM switch

image

Contents

1. Troubleshooting If you have problems with PS 2 connections please make sure that USB legacy support has been disabled in the BIOS Whenever possible use USB ports to connect to the KVM switch PS 2 ports on modern mainboard may not function as they did 15 years ago If you are faced any unexpected problems with the KVM switch please don t hesitate to contact LINDY Support You can reach us worldwide under the contact information provided on our website Or send us an email to support lindy com Firmware Update 1 Please disconnect the servers any cascaded KVM switches and the power supply from the KVM Switch Press and hold port buttons 1 and 3 while re connecting the power supply The Bank No display should now show FF Connect a KVM cable to the Daisy Chain out port of the KVM switch and its other USB cable end to a USB port on a computer with the new firmware 5 The computer will now find a new removable drive named Firmware Copy the new firmware file from your computer on to this drive 6 Disconnect the KVM cable and reboot the KVM Switch by un plugging and re plugging the power supply to complete the installation amp W P FCC Statement Shielded cables must be used with this equipment to maintain compliance with radio frequency energy emission regulations and ensure a suitably high level of immunity to electromagnetic disturbances FCC Warning This equipment has been tested and found to comply w
2. KVM switch FE FOR COMMERCIAL USE ONLY Tested to comply with FCC Standards C lt 1 No 39523 39524 39525 LINDY FIRST EDITION SEP 2013 Operation Computer Port Switching You can select the computer you want to access in three different ways Front panel push button selection Keyboard hotkey selection On screen display menu selection OSD Front Panel Push Buttons not available for the 8C version integrated in an LCD Terminal You may select a computer by pressing the appropriate port push button on the front bezel Slave KVM switch ports cannot be selected from the master KVM front bezel buttons You may either use the OSD or the port button on the slave KVM Basic Keyboard Hotkeys and OSD Commands Press the following key combination to enter the OSD menu Factory Default Hotkey is Scroll Lock it can be changed via the OSD configuration Within 2 seconds a So N N d Scroll Scroll 4 monitor and you can use the cursor keys to Lock aa Lock ii spacebar navigate through the OSD and select functions by Lamm AN pressing the Return key With a small delay the OSD pops up on your Alternatively you can press the initial Scroll Lock hotkey twice and further keyboard hotkey commands within 2 seconds after the initial hotkey to switch computer ports directly or change the KVM Switch settings etc Available direct hotkey commands Command Action Cursor up Cursor down Se
3. Lock space bar Main OSD Menu Select computer port use Up Down Arrow key to navigate Page Up Page Down to scroll page hit Enter to select Edit computer name just hit Insert key to edit the name and Enter to confirm Pat o gt Server connected via PS 2 Accessed and displayed server 5 Server connected via USB Symbols F1 Setup open amp toggle Setup menus Setup OSD Menu Admin menu version Auto logout specify the timeout before an auto fe ee uration logout is performed 0 disabled 5 10 60 Load default min only active when password protection is D i enabled Hotkey specify the hotkey preceding sequence SCROLL LOCK CAPS F12 or NUM LOCK Security Settings Admin only The KVM switch supports password protection for one ADMIN and 3 USERS the default status is OFF It can be enabled via OSD and User rights Access Setup menu have to be set individually for every port Grant View Deny Also users can have individual settings for timeouts and OSD amp port info position Admin and user passwords also have to be User Profile Setup defined via OSD and must be stored when Password ora leaving the OSD After the next Logout via F10 Access setup button or auto logout the security options are Titie bar Titie duration enabled OSD appearance Password Enable Disable password protection Load Default reset all settings to default Upgrade the firmware see below DDC Configuration U
4. port modular C version for installation in the back of a LINDY LCD KVM Terminal Package Contents KVM Switch COMBO 8 16 or 8C Power adapter standalone version only 19 Rack mount kit standalone version only Daisy Chain Cable standalone v only Manuals DE FR IT English Terminator standalone version only Cable Requirements Connect your local monitor USB mouse and USB keyboard using standard cables To cascade KVM Switches via daisy chain port use the supplied daisy chain cable To connect servers to the switch use appropriate KVM system cables as following KVM System cable with VGA amp USB 1m 33770 2m 33771 3m 33772 5m 33773 KVM System cable with USB amp PS 2 connectors 2m 33774 Installation Optional KVM over IP Module If you wish to install the optional module No 39636 into the KVM switch unplug the power supply from the KVM switch Then install the KVM over IP module e For regular installation connect the power supply and then the local console e Connect the servers by appropriate KVM system cables as above Use USB cables whenever possible e To daisy chain multiple KVM Switches connect the Daisy Chain OUT port of the Master KVM Switch to the Daisy Chain IN port of the next slave using the supplied Daisy Chain Cable Longer cables are available from LINDY No 39637 1m 39638 2m Up to a total of 8 KVM switches can be daisy chained Attach the supplied terminator to the last slave
5. ith the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense WEEE Waste of Electrical and Electronic Equipment Recycling In 2006 the European Union introduced regulations WEEE for the collection and recycling of all waste electrical and electronic equipment It is no longer allowable to simply throw away electrical and electronic equipment Instead these products must enter the recycling process Each individual EU member state has implemented the WEEE regulations into national law in slightly different ways Please follow your national law when you want to dispose of any electrical or electronic products More details can be obtained from your national WEEE recycling agency CE Statement Shielded cables must be used with this equipment to maintain compliance with radio frequency energy emission regulations and ensure a suitably high level of immunity to electromagnetic disturbances This equipment complies
6. lect next lower higher port Page Up Page Down Select next higher lower bank KVM switch Scroll Num Caps ESC F12 Change primary hotkey OTOT serimi 0816 Bank port number direct selection T Default on OSD port info screen on off S Start Autoscan Further more detailed options are available via OSD menu Auto LOGOUT and Password Security Function During normal operation and if the password security feature has been enabled if no input from the keyboard or mouse is received for the Auto Logout Time the KVM switch will turn off the display Upon the next keyboard or mouse input the OSD Login window will appear prompting for user name and password Please note your password in a secure place Whenever a connected server switches into a low power state only a black screen will be displayed when this server port is selected Please try to wake up the server and wait for the appropriate time period The KVM OSD should be displayed independently of the server s power state On Screen Display Menu OSD amp Port Selection The OSD menu provides a lot of information about the switch configuration and the attached computers and offers advanced administration and full KVM Switch control to the user An OSD Title bar can be displayed to show the actually active server port Duration and position can be configured see further below Activate the OSD by the hotkey sequence Scroll Lock Scroll
7. se default DDC data or read DDC data from the attached monitor OSD Timeout specify OSD timeout 0 disabled 5 10 60 s Title bar Specify the title bar position on screen Left Right Disable Title Duration specify duration how long the port info is displayed on screen 0 always 5 10 60S AutoScan period Specify the duration time per port for auto scan 10 15 60 s Read OnT EST DDC
8. with the requirements relating to Electromagnetic Compatibility Standards EN55022 EN55024 and the further standards cited therein It must be used with shielded cables only It has been manufactured under the scope of RoHS compliance KVM Switch Combo 8 16 8C BIINDYe Manual CONNECTION PERFECTION This Quick Guide provides an introduction to the Combo 8 16 8C KVM switch and how to set up the device for use The operating instructions for the KVM over IP module are referred in the user manual supplied with KVM over IP module The LINDY Modular KVM Switch Series COMBO 8 16 8C The COMBO 8 16 KVM switch series provides either 8 or 16 KVM server ports Up to 8 KVMs can be daisy chained with each other for connection of up to 128 servers This KVM switch series incorporates a modular concept design which allows for dual access The local console port provides direct access whilst the second console option permits remote access via KVM over IP slot in module This allows system administrators to access and administer their servers and KVM switches from a remote office workstation or via the internet The COMBO 8 16 series KVM switches are compatible with servers using standard VGA and USB keyboard and mouse signals PS 2 connections are also supported to a large extent but dependent on BIOS and legacy settings Whenever possible USB connection should be used The COMBO 8 16 KVM switches are available as standalone models whilst an 8