1. Number in Figure 2 1 Component Description or 2 2 1 1 Power 1 LED Lights green when power input 1 is ON Off when no power is being supplied 2 1 Power 2 LED Lights when power input 2 is ON Off when no power is being supplied 3 1 Alm LED Lights red when the port link is disconnected or power fails 4 1 SFP LED Lights green when an SFP fiber transceiver is connected 5 1 SFP open slot SFP module installs here 6 4 RJ 45 connectors Link to 10 100 1000BASE T network devices 7 NOT USED NOT USED 8 4 Network LEDs Lights green when a network device is detected and linked 9 1 grounding screw Links to ground 10 1 6 pin terminal block Links to 2 power inputs and event alarm output 11 1 6 position DIP switch Sets alarm to port or power event Page 10 724 746 5500 blackbox com Chapter 3 Installation 3 Installation 3 1 DIN Rail Mounting The DIN Rail clip already attached on the rear side of the switch supports an EN 50022 standard DIN Rail as shown in Figure 3 1 4 135 35cm emm 0 295 0 75 cm la 1 063 2 7 cm k Figure 3 1 DIN rail mounting Follow the steps below to mount the switch on the DIN Rail track 1 Insert the upper end of the DIN Rail clip into the back of the DIN Rail track from its upper side 2 Lightly push the bottom of the DIN Rail clip into the track 3 Check if the DIN Rail clip is tightly attached to the track 4
2. M M M OR 8 PE MP MERERETUR e EEE IHENEREEREILHRLEEERUNEEEREEREEFEER 8 PEE c e H 8 o E 8 ZA Hardware Descriptio iva ad 9 3 Ioue T 11 34 Din Rail MOUNN O so said 11 3 2 Hardware Installation 5e steel ae tee eamm e RE pat Been ti eee pr uie a 12 3 2 4 Wiring the DE Power INPUTS cesi eese ecc coe ecu Seen eei euablannkchieherlleinen 12 3 2 2 Wiring ihe Alarm Relay eet ette tido adaa atris bestes dicas 12 3 2 3 Wiring Earth Grounding ssssssssssssssssssseeeeeeeeeenenneneenn eren nen eren rnr eren erre enne nnns 13 5 2 4 Enabling the Event Alarm EUBICHOL e Sez ttes een le elle 13 E e e ALII EDU IET ATE 14 d SSystemeDIagrnOStlCs ans a uui um Heu quitur LIN eii 15 724 746 5500 blackbox com Page 5 Chapter 1 Specifications 1 Specifications Alarm Contact One relay output with current carrying capacity of 1A 24 VDC Approvals FCC Part 15 Subpart B Class A UL60950 1 2nd Ed CSA C22 2 No 60950 1 07 2nd Ed CE EMI EN55022 Class A FCC Part 15 Class A CE EMS EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 CS Shock IEC60068 2 27 Vibration IEC60068 2 6 RoHS IEEE 2002 95 EC IP Protection IP31 Buffer Memory 1 MB Cable RJ 45 ports 10BASE T Category 3
3. 4 5 UTP STP up to 328 ft 100 m 100BASE TX Category 5 UTP STP up to 328 ft 100 m 1000BASE T Category 5e UTP STP up to 328 ft 100 m SFP open slot 62 5 125 um multimode fiber optic cable up to 220 m 850 nm or 2 km 1300 nm 50 125 um multimode fiber optic cable up to 550 m 850 nm or 2 km 1300 nm 9 125 um single mode fiber optic cable up to 30 km Data Rate 10 100 1000 Mbps Enclosure IP31 rated aluminum alloy case Filtering Forwarding Rates 1000 Mbps port 1 488 000 pps 100 Mbps port 148 800 pps 10 Mbps port 14 880 pps Quality of Service QoS for packet forwarding precedence Processing Type Flow Control IEEE802 3x flow control backpressure flow control Jumbo Frames 9 Kbytes MAC Address 2K Mounting DIN rail wallmounting Network Standards IEEE 802 3 802 3u 802 3x 802 3ab 802 3z Store and forward Environment Temperature Tolerance Operating temperature 4 to 158 F 20 to 70 C Storage temperature 22 to 4 176 F 30 to 80 C User Controls 1 DIP switch for port break alarm Normal Open Default setting Disabled Connectors 4 10 100 1000BASE T autonegotiating RJ 45 full half duplex auto MDI MDI X 1 1000 Mbps Gigabit SFP slot compatible SFPs include LFPA11 LFP412 LFP413 LFPA14 LFP416 Indicators 5 LEDs 1 PW1 1 PW2 1 Alarm 1 1000M 1 Link Activity Power Removable 6 pin terminal block redundant in
4. de seguridad y operaci n deber n ser leidas antes de que el aparato el ctrico sea operado Las instrucciones de seguridad y operaci n deber n ser guardadas para referencia futura Todas las advertencias en el aparato el ctrico y en sus instrucciones de operaci n deben ser respetadas Todas las instrucciones de operaci n y uso deben ser seguidas El aparato el ctrico no deber ser usado cerca del agua por ejemplo cerca de la tina de ba o lavabo s tano mojado o cerca de una alberca etc El aparato el ctrico debe ser usado nicamente con carritos o pedestales que sean recomendados por el fabricante El aparato el ctrico debe ser montado a la pared o al techo s lo como sea recomendado por el fabricante Servicio El usuario no debe intentar dar servicio al equipo el ctrico m s all a lo descrito en las instrucciones de operaci n Todo otro servicio deber ser referido a personal de servicio calificado El aparato el ctrico debe ser situado de tal manera que su posici n no interfiera su uso La colocaci n del aparato el ctrico sobre una cama sof alfombra o superficie similar puede bloquea la ventilaci n no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilaci n El equipo el ctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros aparatos incluyendo amplificadores que producen calor E
5. IA 568 100 ohm Max 328 feet 100 m 100BASE TX 2 pair UTP STP CATS cable EIA TIA 568 100 ohm Max 328 feet 100 m 1000BASE T 4 pair UTP STP CAT5 cable EIA TIA 568 100 ohm Max 328 feet 100 m NOTE For optimum data transmission and power delivery in any speed use CAT5 cable or above Fiber port Port 5 houses a fiber transceiver SFP See the table below for compatible SFPs Table 3 3 Compatible SFPs Part Number Description LFP411 SFP 1 25 Gbps Fiber with Extended Diagnostics 850 nm Multimode LC 300 m LFP412 SFP 1 25 Gbps Fiber with Extended Diagnostics 1310 nm Multimode LC 2 km LFP413 SFP 1 25 Gbps Fiber with Extended Diagnostics 1310 nm Single Mode LC 10 km LFP414 SFP 1 25 Gbps Fiber with Extended Diagnostics 1310 nm Single Mode LC 30 km LFP416 SFP with SGMII Interface 1 25 Gbps Copper 10 100 1000BASE T Extended Diagnostics SFP Installation Before installing the SFP transceiver make sure the SFP type at both ends of the link is the same and the transmission distance wavelength fiber cable are correct for your application At both ends of the connection simply plug the SFP transceiver into the switch then connect the fiber cable Page 14 724 746 5500 blackbox com Chapter 4 System Diagnostics 4 System Diagnostics Do a ping test to make sure the installation is correct Ping 192 168 1 1 Ping 192 168 1 1 PC host i T
6. LGH1004A lt gt BLACK BOX Customer Order toll free in the U S Call 877 877 BBOX outside U S call 724 746 5500 Support FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Inf ti Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 JEU et Web site www blackbox com E mail info blackbox com Trademarks Used in this Manual Trademarks Used in this Manual Black Box and the Double Diamond logo are registered trademarks of BB Technologies Inc Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners Disclaimer Black Box Network Services shall not be liable for damages of any kind including but not limited to punitive consequential or cost of cover damages resulting from any errors in the product information or specifications set forth in this document and Black Box Network Services may revise this document at any time without notice We re here to help If you have any questions about your application or our products contact Black Box Tech Support at 724 746 5500 or go to blackbox com and dick on Talk to Black Box You ll be live with one of our technical experts in less than 60 seconds Page 2 724 746 5500 blackbox com FCC and IC RFI Statements Federal Communications Commission and Industry Canada Radio Frequency Interference Statements This equipment generates uses and can radiate ra
7. To remove the switch from the track reverse the steps 1 3 above 724 746 5500 blackbox com Page 11 Chapter 3 Installation 3 2 Hardware Installation 3 2 1 Wiring the DC Power Inputs Before installing the power input make sure the DC power supply complies with standard power supply certifications NOTE Suitable wire gauge is from 12 to 24 AWG Follow these steps to wire the DC power cable to the connector 1 Insert the positive and negative wires into the V and V contacts on the terminal block connector 2 Tighten the wire clamp screws to prevent the DC wires from loosening V and V contacts Wire clamp screws Figure 3 2 Terminal block connector 3 2 2 Wiring the Alarm Relay The switch provides one dry relay output for a power or port link event The alarm relay default is open and forms a closed circuit when the event occurs The relay conductor has a maximum of 24 Watts When it connects with a 24 VDC power source the maximum current is 1 Amp The following diagram shows how to create an alarm circuit WARNING Do not connect to AC line Grounding screw Alm o000000 7 000000 t Alarm Control porti 5 m power Ground Figure 3 3 Alarm relay wiring Page 12 724 746 5500 blackbox com Chapter 3 Installation 3 2 3 Wiring Grounding AC motors electric welding machines and power devices generate electromagnetic and disturb communications To prevent noise be su
8. arget device IP address IP address 192 168 1 10 Ethernet cable Ethernet cable 192 168 11 lt I Reply to 192 168 1 10 Reply to 192 168 1 10 Power Supply Figure 4 1 Connection for ping test 1 Click on Run in the Windows Start Menu type Command then click OK m Type the name of a program folder document or Internet resource and Windows will open it for you Figure 4 2 Open command 724 746 5500 blackbox com Page 15 Chapter 4 System Diagnostics 2 Type ping 192 168 1 1 command in the command window The PC host 192 168 1 10 will then ping the target PC The screen below shows the result you will get if you successfully ping the target IP address for example 192 168 1 1 WINNT System32 command com 192 168 1 1 Pinging 192 168 1 1 with 32 Reply from 192 168 1 1 Reply from 192 168 1 1 Reply from 192 168 Reply from 192 168 loss ate roun Minimum Gms Figure 4 3 Ping results screen NOTE If you failed to ping the target IP the command mode will show Ping Request Timeout Check the IP address settings of the PCs Ethernet cable connections and the port LEDs to identify the problem Page 16 724 746 5500 blackbox com NOTES 724 746 5500 blackbox com Page 17 NOTES Page 18 724 746 5500 blackbox com NOTES 724 746 5500 blackbox com Page 19 Black Box Tech Support FREE Live 24 7 Tech support the way it sho
9. dio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio communication It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of Industry Canada Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la classe A prescrites dans le R glement sur le brouillage radio lectrique publi par Industrie Canada 724 746 5500 blackbox com Page 3 N In OM Statement strucciones de Seguridad Normas Oficiales Mexicanas Electrical Safety Statement 1 2 3 4 5 oN Oo 10 11 Todas las instrucciones
10. indicate power alarm speed and link activity e Supports store and forward switching architecture e P 31 aluminum alloy case e Compact unit mounts on a DIN rail or wall 2 3 What s Included Your package includes one Hardened Ethernet Switch It has 4 10 100 1000 Mbps twisted pair ports and 1 1000 Mbps Gigabit SFP slot This user manual installation guide can be downloaded from the Black Box Web site or the FTP site To download from the Web site 1 Go to www blackbox com 2 Enter the LGH1004A in the search box Hello Sign In or Register 0 items Account Cart S SUPPORT ABOUT Talk with an Expert 3 Click on the Resources tab on the product page and select the document you wish to download To download from the FTP site 1 Go to ftp blackbox com 2 Open the Manuals folder if using IE open the Anonymous folder first 3 Open the L folder then search for LGH1004A Page 8 724 746 5500 blackbox com Chapter 2 Overview 2 4 Hardware Description The front panel of the Gigabit Ethernet Switch is shown in Figure 2 1 The bottom panel is shown in Figure 2 2 123 PWR1 2 Alm o Figure 2 1 Front panel of the switch Figure 2 2 Bottom panel of the switch Go to the next page for a description of the switch components shown in the diagrams above 724 746 5500 blackbox com Page 9 Chapter 2 Overview Table 2 1 Hardened Ethernet Switch components
11. l aparato el ctrico deber ser connectado a una fuente de poder s lo del tipo descrito en el instructivo de operaci n o como se indique en el aparato 12 Precauci n debe ser tomada de tal manera que la tierra fisica y la polarizaci n del equipo no sea eliminada 13 Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados Sobre o contra ellos poniendo particular atenci n a los contactos y recept culos donde salen del aparato 14 El equipo el ctrico debe ser limpiado nicamente de acuerdo a las recomendaciones del fabricante 15 En caso de existir una antena externa deber ser localizada lejos de las lineas de energia 16 El cable de corriente deber ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo 17 Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilaci n 18 Servicio por personal calificado deber ser provisto cuando A El cable de poder o el contacto ha sido da ado u B Objectos han ca do o l quido ha sido derramado dentro del aparato o C El aparato ha sido expuesto a la lluvia o D El aparato parece no operar normalmente o muestra un cambio en su desempe o o E El aparato ha sido tirado o su cubierta ha sido da ada Page 4 724 746 5500 blackbox com Table of Contents Table of Contents Te SPCCHIGATOMNS ERR ETT A 6 2 WOU OWN
12. puts Input 12 48 VDC 3 36 Watts maximum NOTE Includes reverse polarity protection Page 6 724 746 5500 blackbox com Chapter 1 Specifications Specifications continued Dimensions 2 2 H x 4 3 W x 4 7 D 5 5 x 10 8 x 12 cm Weight 1 54 Ib 0 7 kg 724 746 5500 blackbox com Page 7 Chapter 2 Overview 2 Overview 2 1 Description The Hardened Ethernet Switch has four 10 100 1000 Mbps RJ 45 ports and one Gigabit SFP open slot To operate in harsh environments the switch provides two power inputs that can be connected simultaneously to live DC power sources If one of the power inputs fails the other live source acts as a backup to automatically support the switch s power needs It also has a built in smart alarm that alerts you when power fails or a port disconnects The switch is hardened for use in temperatures ranging from 4 to 158 F 20 to 70 C has an IP31 aluminum case and also has a DIN rail and wallmounting installation kit 2 2 Features Hardened metal enclosure for use in extreme temperatures ranging from 4 to 158 F 20 to 70 C Resists dust dirt moisture smoke and insects e Provides four 10 100 1000 Mbps RJ 45 ports and one 1000BASE X Gigabit SFP open slot Has redundant live DC power inputs If one of the DC power inputs fails the other source acts as a backup A built in smart alarm alerts you when power fails or a port connection breaks e LEDs
13. re to ground the switch The following diagram shows how to create a connection Alarm system Maximum 1 A current 24 VDC 2000000 000200060 Alarm Control port 1 5 power Extra power system Figure 3 4 Grounding the switch 3 2 4 Enable the Event Alarm Function The switch has one dry relay output for port link fails or power fails Just change the DIP switch to the desired setting and the new configuration will be activated You don t need to reset the system On the bottom side of the switch there is one 6 pin DIP switch for alarm control Insert the power and port wiring and the DIP switch for the intended alarm is switched to ON The relay output will form a short circuit if the alarm occurred Aim 60 OO O O0 Ap AE DR 000000 Alarm Control m porti 5 r power 000008 Figure 3 5 Setting the DIP switch Table 3 1 DIP switch settings for port link or power failure alarm Pin Number Status Description P1 to P Pin 1 5 ON Enables port link down alarm at this port OFF Disables port link down alarm at this port P6 ON Enables power failure alarm OFF Disables power failure alarm 724 746 5500 blackbox com Page 13 Chapter 3 Installation 3 2 5 Cabling Ethernet Cabling Ports 1 4 use copper UTP STP cable Table 3 2 Cable types for data transmision Description 10BASE T 2 pair UTP STP CAT3 4 5 cable EIA T
14. uld be Great tech support is just 60 seconds away at 724 746 5500 or blackbox com BLACK BOX About Black Box Black Box provides an extensive range of networking and infrastructure products You ll find everything from cabinets and racks and power and surge protection products to media converters and Ethernet switches all supported by free live 24 7 Tech support available in 60 seconds or less Copyright 2014 Black Box Corporation All rights reserved Black Box and the Double Diamond logo are registered trademarks of BB Technologies Inc Any third party trademarks appearing in this manual are acknowledged to be the property of their respective owners Igh1004a version 1 724 746 5500 blackbox com