Home
Tuncmatik Lite II 850VA
Contents
1. LITE I 650 850 VA UNINTERRUPTIBLE POWER SUPPLY UPS USER MANUAL 5 tuncmatik www tuncmatik com pure power This UPS is specially designed for Personal Computers with multi functions Its light weight compact design perfect fits to the limited working environment The line of UPS is equipped with boost and buck AVR to stabilize input voltage range It is also built in with DC Start function This function enables the UPS to be started up without AC power supplied The main features of UPS are listed below gt Compact size light weight gt Microprocessor control guarantees high reliability gt Equipped with Boost and Buck AVR gt Green Power Function for energy saving gt DC Start Function Cold Start gt Auto restart while AC recovery gt Provides AC Overload protection INTRODUCTION Lite I 650 Front Panel Lite I 350 Back Panel 1 Smart On Off Button 3 AC Input 2 AC Mode Green Lighting 4 Output Receptacles Battery Mode Orange Flashing 5 Circuit Breaker Fault Red Lighting SMART BUTTON TECHNOLOGY ALARM SILENCE FUNCTION Smart On Off Button Technology Alarm Silence Function Press the smart button for minimum 1 second to turn the UPS unit on If mains is cut off when UPS is working UPS starts working in battery mode and gives audible alarm If you press smart button once UPS audible alarm stops Alarm Silence Function lf the smart button is pressed once again the a
2. ber gloves and boots 4 Do not lay tools or metal parts on top of batteries 5 Disconnect charging source prior to connecting or disconnecting batteries terminals When replacing batteries replace with the same number and type of sealed lead acid battery The maximum ambient temperature raling is 40 C This pluggable type A equipment with battery already installed by the supplier is operatar installable and may be operated by laymen During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3 5 mA The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible TROUBLE SHOOTING Use the table below to solve minor problems Problem Possible Cause Solutions No LED display on Low battery Charge the UPS at least 6 hours the front panel Battery fault Replace the battery with the same type of battery pes see Safety Warning page The UPS is not turned on Press the On Off button at least 1 second to turn on the UPS Alarm continuously The UPS is overload Remove some loads first Before sounds when the reconnecting equipment please mains is normal verify that the load matches the UPS capability specified in the specs Please see Technical Specification table When power fails The UPS is overload Remove some critical load back up time is shorten Battery voltage is too Charge the UPS a
3. ct one computer related device into each of the power receptacles supplied on the back of the UPS o Turn On Off DTE e Press the smart button for minimum 1 second to turn the UPS unit on Press the smart button until the LED turn into red then remove S your finger to shut down the UPS unit 6 DC Start All Series are equipped with DC Start Cold Start To start the UPS when AC utility power is not available simply press the smart button for minimum 1 second SAFETY WARNING A This UPS utilizes voltages that may be hazardous Do not attempt to disassemble the unit The unit contains no user serviceable parts Only factory service personnel may perform repairs Internal battery voltage is 12Vdc Sealed lead acid 6 cells battery Connection to any other type of receptacle other than a two pole three wire grounded receptacle may result in shock hazard as well as violate local electrical codes In the event of an emergency press the Smart On Off Button for 4 seconds and disconnect the power cord from the AC power supply to properly disable the UPS Do not allow liquids or any foreign object to enter the UPS Do not place beverages or any other liquid containing vessels on or near the unit This unit intended for installationina controlled environment temperature controlled indoor area free of conductive contaminants Avoid installing the UPS in locations where there is standing or running water or exce
4. larm starts again After UPS alarm is silenced when battery capacity drops to a critical level the audible alarm starts automatically again and cannot be silenced Press the On Off smart button until the LED turn into red ea then remove your finger to shut down the UPS unit Smart 1 Inspection Remove the UPS from its packaging and inspect it for damage that may have occurred during shipping If any damage is discovered repack the unit and return it to the place of purchase 2 Charging This unit is shipped from the factory with its internal battery fully charged however some charge may be lost during Shipping and the battery should be recharged prior to use Turn on the UPS Plug the unit into an appropriate power Supply and allow the UPS to charge fully by leaving it plugged in for at least 6 hours with no load no electrical devices such as computers monitors etc connected Green LED flashes while UPS charging 3 Placement Install the UPS unit in any protected environment that provides adequate airflow around the unit and is free from excessive dust corrosive fumes and conductive contaminants Do not operate your UPS in an environ ment where the ambient Snes or Tue is high On the other hand place the UPS away 20cm from the monitor at lt least 20 cm to avoid interference 4 Connection Plug the UPS into a 2 pole 3 wire grounded receptacle Then conne
5. ssive humidity Do not plug the UPS input into its own output Do not attach a power strip or surge suppressor to the UPS Do not attach to non computer related items such as medical equipment life support equipment microwave ovens vacuum cleaners lazer printers or washing machine To reduce the risk of overheating the UPS do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces Unplug the UPS prior to cleaning and do not use liquid or spray detergent Do not dispose of batteries in a fire as they may explode Do not open or mutilate the battery or batteries Released electrolyte is harmful to the skin and eyes It may be toxic Attention hazardous through electric shock Also with disconnection of this unit from the mains hazardous voltage still may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole of the battery when maintenance or service work inside the UPS is necessary Servicing of batteries should be performed by authorized personnel Keep unauthorized personnel away from batteries A battery can present a risk of electrical shock and high short circuit current The following precautions should be observed when working on batteries 1 Remove watches rings or other metal objects from the hands 2 Use tools with insulated handles 3 Wear rub
6. t least 6 hours low Battery defect It might Replace the battery with the same be due to high type of battery Please see temperature operation _ Safety Warning page environment or improper operation to battery The mains is normal Power cord is loose Reconnect the power cord properly if but LED color in red the problem can t be solved please is flashing consult nearest technical service TECHNICAL SPECIFICATIONS WO B E Lite II 650 VA Lite 11850 VA Capacity 650 VA 360 W 850 VA 480 W INPUT Voltage 220 230 240 VAC 162 290 VAC Voltage Range OUTPUT Voltage Regulation 10 Transfer Time Typical 2 6 ms 10 ms max Waveform Simulated sine wave BATTERY Type amp Number 1X 12V 7AH 1 X 12V 9AH Charging Time 4 6 hours recover to 90 capacity PHYSICAL Dimensions DxWxH 322 x 122 x 160 mm Net Weight kg 4 5 kg ENVIRONMENT Humidity 0 40 C 0 90 Non condensing lt 40 dB 5 1 kg Noise Level tuncmatik procio ni rl 3 E i a a tuncmatik natural resources pure power