Home

Barco MDRC-2224 WP

image

Contents

1. 26 Indications for use This display is an AMLCD display designed for viewing medical X ray images This unit should not be used near patients where patients are likely to be in unconscious condition and should be kept outside of 1 83 m perimeter and 2 29 m vertical K5903081 EONIS 17 06 2014 7 Important information FCC class B This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference re ceived including interference that may cause undesired operation This device has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This device generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this device does cause harmful interference to radio or television reception which can be determined by turning the device off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation
2. 18 5 9 DPMS MOIE ee y uyw ssp E PU nece e TA TEE Ie E 18 5 10 Self calibration frequency 2 2 02 02 21 7 4 40 2 2 2222 19 5 11 Eactory ed bie desk Peg diee DR Fade egre 19 6 en aa SEA Da ERI RO eG 21 6 1 Cleaning Instr ctiorns 21 T Important information 23 CA SalelyInforinatidrt yu 2 sas EE Eu ERG a ne pe a Uri quA yaaa us u masi 23 1 29 Environmental information oo bedstead ree dee eh ee 25 7 3 Regulatory compliance information 26 TA EMC HOME 3 y 27 7 5 CExplanation on symbols ee re bb EE rama Md ddd 30 Te Legal disclaimer 3 5 d deer Rb VERE ee m dde dd RR Ad 33 Lf 3echriical specificatlons o eee rms EE d n ua bib bey eee Ded dde at IE Oy 33 A Troubleshooting_ u u UEM 37 Troubleshooting oo cade Sua au uu 37 Az Warning Signal 2222 uuu 37 K5903081 EONIS 17 06 2014 _ 1 Table of contents 2 _ K5903081 EONIS 17 06 2014 7 Welco
3. Connect the supplied external DC power supply to the 12 VDC power input of your display Plug the other end of the external DC power supply into a grounded power outlet by means of the proper power cord delivered with your display T n a B p 0000 Mies Image 3 3 For the MDRC 2224 WP there is a earth stud available in the connector compartment K5903081 EONIS 17 06 2014 3 Display installation 3 4 Re attaching the cover To re attach the connector compartment cover Put the cover back in position by sliding it downwards so that it is fixed to the display again Pay attention that all cables stay in the cable channel while re attaching the cover E Image 3 4 3 5 Routing the cables To route the cables 1 Slide the cable routing strap through the opening in the back of the stand 2 Bundle all cables together so that they will fit in the strap 3 Wrap and fix the cable routing strap around all cables Image 3 5 3 6 Kensington security slots To make use of the Kensington security slots Your Eonis display has 2 Kensington slots available which allow you to secure the display to a desk or any other fixed object Moreover when locking the display with the connector compartment cover attached you also prevent users from co
4. non condensing Storage amp transport humidity 5 90 non condensing at 39 deg ambient Operation altitude 3000 m torage amp transport altitude 5500 m Operating pressure 70 kPa 106 kPa Storage amp transport pressure 50 kPa 106 kPa K5903081 EONIS 17 06 2014 Troubleshooting TROUBLESHOOTING 1 Troubleshooting General If you experience trouble with the LCD display refer to the following troubleshooting If the problem per sists please contact your local dealer or our service center Problem No image appears on the screen Push the standby button e Checkifalll O and power connectors are correctly connected as described in the installation section Make sure the pins of the connectors are not crooked or broken Problem Partial image or incorrectly displayed image Check to see if the resolution of your computer is higher than the resolution of the display Re configure the resolution of your computer to make it less than or equal to the native resolution 1920 x 1200 Problem Partial image or incorrectly displayed image Use Clock to make an adjustment e Check and re configure the display mode of the vertical refresh rate of your graphics card to make it compatible with the display Problem Image is unstable and flickering Use Phase to make an adjustment Problem Image is scrolling e Check and make sure the VGA signal cable or adapter is well connecte
5. You can now safely pivot tilt swivel raise and lower your display as desired w Image 3 1 mode make sure you change the orientation of the video input via the screen settings The standard orientation of the video input is landscape If you use the display in portrait of the computer WARNING Put the display highest position before pivoting the display The display will be delivered in portrait mode Pivot the display 90 to use it inlandscape mode 3 2 Removing the cover To remove the connector compartment cover The connector compartment cover should be removed to get access to the connectors To remove the cover gently slide the connector compartment cover upwards and remove it from the display K5903081 EONIS 17 06 2014 _ 7 3 Display installation m S r Uma 05 2 9 Image 3 2 3 3 Connecting the cables To connect the cables 1 2 3 4 5 Connect one or more of the video input connections of your display VGA HDMI or DisplayPort to the corresponding video outputs on your computer or any other video device If you want to make use of the displays USB downstream connectors then connect your workstation with the display s USB upstream connector by means of the supplied USB cable Connect a speaker amplifier with the display s audio line out if you want to use the internal sound option of your display
6. be automatically selected when gamma functions are defined by MediCal QAWeb To select a gamma function 1 Bring up the OSD main menu 2 Navigate to the Adjustments menu 3 Enter the Gamma submenu 4 Select one of the available gamma functions 5 4 Ambient light reading room selection About ambient light reading rooms The available ambient light reading rooms for your display are Dark Room Corresponds to light conditions in dark diagnostic reading rooms This setting has the lowest maximum ambient light Office Corresponds to light conditions in office rooms Operation Room Corresponds to light conditions in operating rooms This setting has the highest maximum ambient light QAWeb This setting will be automatically selected when ambient light conditions are defined by Med iCal QAWeb To select an ambient light reading room 1 Bring up the OSD main menu 2 Navigate to the Adjustments menu 3 Enter the Ambient Light submenu 4 Select one of the available reading rooms and confirm 5 5 White point selection About white point selection This setting allows you to modify the display white point used as reference for all other colors to be dis played The available white point settings for your display are Native The native unmodified color temperature of the LCD panel 6500K sRGB Corresponds to a color temperature of 6500 Kelvin D65 QAWeb This white point setting will
7. e 10 4 Daily operation 2 u uyay YZ RE EE Rr we puas 13 4 1 Recommendations for daily operation 13 4 2 On Off switching Door Ie ee cre o Pra e n a a Pa Uo CLA d etel ee 14 4 3 Bringing up the OSD essem emet 14 4 4 Navigating through the OSD 2 2 0 0 7 7 7 7 7 7 4 14 S Advanced u seins i e E EnA ETE E UA RPG aC RAE ME 15 5 1 Video input source 2 2 2 0 02 15 5 2 L minarnce adJ stmient u a SS Er axem eh n die 15 5 3 Gammia selectlori zs saa cae Ata ld emo nae Bk Seiad i edd a aa ie 15 5 4 Ambient light reading room selection 2 2070 02 120222222 16 5 5 White point 2 2 2 2 2 16 5 6 Analog video 08 4 0 17 5 7 OSD menu eee ieee A Life a ge see ener 17 5 8 Power sstatus LED ee ere ie eR Dog RR eee aee eee
8. g UL EN IEC 60950 for IT equipment and UL EN 60601 1 IEC 60601 series for medical electrical equipment In addition all such combinations systems shall comply with the standard IEC 60601 1 1 safety requirements for medical electrical systems Equipment not complying with UL EN IEC 60601 1 shall be kept outside the patient environment as defined in the standard Equipment not complying with IEC 60601 must be kept outside the patient environment as defined in the standard as at least 1 5 meters from the patient or the patient support Any person who connects external equipment to signal input signal output or other connectors has formed a system and is therefore responsible for the system to comply with the requirements of IEC 60601 1 1 If in doubt speak with a qualified technician In locations where 240 V outlets are used connect this display only on a center tapped 240 V single phase supply Water and moisture Never expose the device to rain or moisture Never use the device near water e g near a bathtub washbasin swimming pool kitchen sink laundry tub or in a wet basement Ventilation Do not cover or block any ventilation openings in the cover of the set When installing the device in a cupboard or another closed location heed the necessary space between the set and the sides of the cupboard Installation Place the device on a flat solid and stable surface that can support the weight of at least 3 devices If yo
9. name Hazardous substances and elements 4h T KEE FRKA ZRI Pb Hg Cd Cr6 PBB 2 1 p enclosure Heatsinks jm 8 Power Supply Unit PER Paper Manuals CD manual O S amp m CB SUB EU CERE PR ARMA HHS m JZ SIT 11363 2006 DR EE EG bi F O Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ T11363 2006 X SJ T 11363 2006 trem X Indicates that this toxic or hazardous substance contained at least one of the homogeneous materials used for this part is above the limit requirement in SJ T11363 2006 EE TR EB 238 RE rh E K Bh 77 Ra 25 ES n HE Wh FA ABR EFUP RE e Barco FH SEFUPTR 4 18 SRG BARA 56 FIT il EF amp amp rh Es Fih B I PP UR FR All Electronic Information Products EIP that are sold within Chinese Mainland must comply with the Electronic Information Products Pollution Control Labeling Standard of Chinese Mainland marked with the Environmental Friendly Use Period EFUP logo The number inside the EFUP logo that Barco uses please refer to the photo is based on the Standard of Electronic Information Products Environmental Friendly Use Period of Chinese Mainland 10 7 3 Regulatory compliance information
10. 3 P 0 12 0 23 0 73 2 3 23 At 80 MHz and 800 MHz the separation distance for the higher frequency range applies These guidelines may not apply in all situations Electromagnetic propagation is af fected by absorption and reflection form structures object and people 7 5 Explanation of symbols Symbols on the device On the device or power supply you may find the following symbols nonrestrictive list C Indicates compliance with the Directive 93 42 as Class device C Indicates compliance with the Directive 93 42 EEC as Class Il device 0120 Indicates compliance with Part 15 of the FCC rules Class Class 5 For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to the frequency of the transmitter Where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer _ K5903081 EONIS 17 06 2014 7 Important information oil Indicates the device is approved according to the UL regulations il Indicates the device is approved according to the UL regulations for Canada and US Indicates the device is approved according to the UL Demko regulations Indicates the device is approved according to the CCC regulations Indicates the device is approved according to the VCCI regulations Indicates the
11. Eonis User Guide 24 inch clinical display MDRC 2224 WP MDRC 2224 BL K5903081 02 Bance 17 06 2014 Visibly yours President Kennedypark 35 8500 Kortrijk Belgium Phone 32 56 23 32 11 Fax 32 56 26 22 62 Support www barco com esupport Visit us at the web www barco com Printed in Belgium Table of contents TABLE OF CONTENTS T WGICODIGL uuu umu a Na FEE ERE ra DLE NIME RU TED D HM A 3 1 4 About the product AEREE v etd Bae ae kas 3 1 2 Whats e Ra asua aca CODES 4 2 Parts controls and connectors 5 AT Eig E BGB 5 222 ROAR VICW 6 3 Display installation eee 7 3 1 Adjusting the display 2 0 Hmmm 7 3 2 Removing gover uu u u uuu EE BE Ae dde 7 3 3 8 3 4 9 3 5 Routing evite EU UA 9 3 6 slots seinere E ELO Lu DIO due 9 3 7 VESA Mountinstallation
12. Eonis display Most unique however is the excellent cleanability of the white Eonis display thanks to the toughened and scratch proof glass This display model can be disinfected both front and back with typical alcohol based cleaning agents Features Front sensor automatically aligns image quality IPS panel ensures wide viewing angle MediCal QAWeb suite for networked quality assurance calibration and asset management all add to the exceptional consistent image quality of the Eonis display Toughened scratch proof front glass white version only Covered cables Medical grade certifications Sockets for Kensington lock makes the Eonis display safe for use in clinical environments Flexible VESA mount for easy arm wall or cart mounting connections for easy and secure connections Multiple inputs HDMI DisplayPort USB etc ensure the display s flexible deployment This manual further guides you through the different steps needed to install and use the Eonis display CAUTION Read all the important safety information before installing and operating your Eonis display Please refer to the dedicated chapter in this user guide K5903081 EONIS 17 06 2014 _ 3 7 Welcome 1 2 What s in the box Overview Your Eonis comes with this Eonis user guide documentation CD containing multilingual user documentation asystem CD containing MediCal QAWeb Agent set of AC power
13. Use the Right Down and Left Up keys to move through the sub menus change values or make selections 2 To go into a submenu or confirm adjustments and selections use the Menu Enter key 5903081 EONIS 17 06 2014 5 Advanced operation 5 ADVANCED OPERATION 5 1 Video input source selection About video input source selection By default your Eonis display automatically detects and shows the connected video input source How ever when for instance more then one video input source is connected it may be needed to manually select the input source to be displayed The available video input source selections for your display are Auto This is the default setting and will automatically detect and display the connected video input source HDMI This setting will display the video connected to the HDMI input DisplayPort This setting will display the video connected to the DisplayPort input VGA This setting will display the video connected to the VGA input To select a video input source 1 Bring up the OSD main menu 2 Navigate to the nput Selection menu 3 Select one of the available video input sources 5 2 Luminance adjustment About luminance adjustment The luminance of your Eonis display is adjustable over a predefined range When you change the lumi nance the display will adjust its backlight to reach the target To adjust the luminance 1 Bring up the OSD main me
14. Voltage fluctuations flicker Complies network that supplies buildings emissions used for domestic purposes IEC 61000 3 3 K5903081 EONIS 17 06 2014 __ 7 Important information This Eonis complies with appropriate medical EMC standards on emissions to and interference from sur rounding equipment Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Interference can be determined by turning the equipment off and on If this equipment does cause harmful interference to or suffer from harmful interference of surrounding equipment the user is encouraged to try to correct the interference by one or more of the following mea sures e Reorient or relocate the receiving antenna or equipment Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced technician for help Electromagnetic immunity The Eonis is intended for use in the electromagnetic environment specified below The customer or the user of the Eonis should assure that it is used in such an environment Immunity test IEC 60601 Compliance level Electromagnetic environment guidance Electrostatic discharge 6kV contact 6kV contact Floors should b
15. be automatically selected when white point is defined by MediCal QAWeb K5903081 EONIS 17 06 2014 5 Advanced operation To select the white point 1 Bring up the OSD main menu 2 Navigate to the Adjustments menu 3 Enter the White Point submenu 4 Select one of the available white point presets 5 6 Analog video settings The following settings are only available when VGA video input source is selected About analog video settings When the VGA video input source is active a number of analog video settings will become available Auto Adjust The analog video setting will automatically be adjusted Geometry Allows to manually adjust the geometry settings ofthe analog video clock frequency clock phase horizontal position vertical position e Level Allows to manually adjust the contrast and brightness levels of the analog video To adjust the analog video settings 1 Bring up the OSD main menu 2 Navigate to the Adjustments menu 3 Enter the Analog submenu 4 Adjust one of the available analog video settings as desired 5 7 OSD menu language About the OSD menu language By default the OSD menu comes up in English However there s a wide range of other languages avail able for the OSD menu of your Eonis display English French German Spanish Italian Dutch Japanese Traditional Chinese Simplified Chinese Korean To select the language of the OSD menu 1 Br
16. between the device and receiver e Connect the device into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Canadian notice This ISM device complies with Canadian ICES 001 Cet appareil ISM est conforme la norme NMB 001 du Canada T 4 notice General information No specific requirement on the use of external cables or other accessories except power supply With the installation of the device use only the delivered power supply or a spare part provided by the legal manufacturer Using another can result in a decrease of the immunity level of the device Electromagnetic emissions The Eonis is intended for use in the electromagnetic environment specified below The customer or the user of the Eonis should assure that it is used in such an environment D Electromagnetic environment Guidance RF emissions Group 1 The Eonis uses RF energy only CISPR 11 for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment CISPR 11 P all Harmonic emissions Class D Meee Sta tonne Nhe an those directly connected to the IEC 61000 3 2 _ public low voltage power supply
17. cord s depending the region of operation a VGA cable aHDMI cable a DP cable a USB cable an external power supply accessory bag cleaning cloth velcro cable routing strap Keep your original packaging It is designed for this display and is the ideal protection during transport and storage 4 _ 05903081 EONIS 17 06 2014 2 Parts controls connectors 2 PARTS CONTROLS AND CONNECTORS 2 1 Front view Overview te e t J o Image 2 1 Front sensor USB downstream connector Left Decrease key Right Increase key Menu Enter key Standby key Power status LED N gt K5903081 EONIS 17 06 2014 _ 5 2 Parts controls connectors 2 2 Rear view Overview J s di k fo s g EN PN L mm E te 660 0000 Image 2 2 1 2 3 4 5 6 7 8 9 1 0 Connector compartment cover Kensington security slots Opening for cable routing strap 12 VDC power input USB downstream connector USB upstream connector VGA input HDMI input DisplayPort input HDMI audio line out K5903081 EONIS 17 06 2014 3 Display installation 3 DISPLAY INSTALLATION 31 Adjusting the display position To adjust the display position
18. d e Check and re configure the display mode of the vertical refresh rate of your graphics card to make it compatible with the display Problem Vague image characters and graphics Use Clock to make an adjustment If this problem still exists use Phase to make an adjustment A 2 Warning signals General Sometimes you may see warning messages for this display This means that the display cannot correctly receive the signal form the computer graphics card Problem No signal This message means that the display has been powered on but it cannot receive any signal from the computer graphics card Check all the power switches power cables and signal cable K5903081 EONIS 17 06 2014 LLL 37 A Troubleshooting Problem Out of range This message means that the signal of the computer graphics card is not compatible with the display When the signal is not included in the compatibility mode we have listed in the appendices of this manual the display will show this message 38 K5903081 EONIS 17 06 2014
19. dations for daily operation Optimize the lifetime of your display Enabling the Display Power Management System DPMS of your display will optimize its lifetime by auto matically switching off the backlight when the display is not used for a specified period of time By default DPMS is enabled on your display but it also needs to be activated on your workstation To do this go to Power Options Properties in the Control Panel Barco recommends setting DPMS activation after 20 minutes of non usage ce Use a screen saver to avoid image retention Prolonged operation of an LCD with the same content on the same screen area may result in a form of image retention You can avoid or significantly reduce the occurrence of this phenomenon by using a screen saver You can activate a screen saver in the Display properties window of your workstation Barco recommends setting screen saver activation after 5 minutes of non usage A good screen saver displays moving content In case you are working with the same image or an application with static image elements for several hours continuously so that the screen saver is not activated change the image content regularly to avoid image retention of the static elements Understand pixel technology LCD displays use technology based on pixels As a normal tolerance in the manufacturing of the LCD a limited number of these pixels may remain either dark or permanently lit without af
20. device is approved according to the KC regulations Indicates the device is approved according to the BSMI regulations Indicates the USB connectors on the device Indicates the DisplayPort connectors on the device Indicates the manufacturing date J Q GG Indicates the temperature limitations for the device to safely operate within specs lt a Indicates the device serial no Warning dangerous voltage Caution Consult the operating instructions P E 8 6 Values for xx and yy can be found in the technical specifications paragraph K5903081 EONIS 17 06 2014 LLL 1 Z Important information Indicates this device must not be thrown in the trash but must be recycled according to the European WEEE Waste Electrical and Electronic Equipment directive TE Indicates Direct Current DC Indicates Alternating Current AC Stand by Equipotentiality 4 6 Symbols on the box On the box of the device you may find the following symbols nonrestrictive list Indicates a device that can be broken or damaged if not handled carefully when being stored Indicates a device that needs to be protected from moisture when being stored DI Indicates the storage direction of the box The box must be transported handled and stored in such a way that the arrows always point upwards L E Indicates the maximum number of identical boxes which may be stacked on each ot
21. dhere to all warnings on the device and in the operating instructions manual Follow all instructions for operation and use Electrical Shock or Fire Hazard To prevent electric shock or fire hazard do not remove cover No serviceable parts inside Refer servicing to qualified personnel Do not expose this apparatus to rain or moisture Modifications to the unit Do not modify this equipment without authorization of the manufacturer Type of protection electrical Display with external power supply Class equipment Degree of safety flammable anesthetic mixture Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide Non patient care equipment e Equipment primarily for use in a health care facility that is intended for use where contact with a patient is unlikely no applied part The equipment may not be used with life support equipment The user should not touch the equipment nor its signal input ports SIP signal output ports SOP and the patient at the same time Power connection Equipment with external 12 VDC power supply e Power requirements The equipment must be powered using the delivered medical approved 12 VDC power supply The medical approved DC power supply must be powered by the AC mains voltage The power supply is specified as a part of the ME equipment or combination is specified as a ME system To av
22. e disable DPMS mode 1 Bring up the OSD main menu 2 Navigate to the Adjustments gt Settings gt Power Save menu 3 Enter the DPMS submenu 4 Select On or Off as desired and confirm 18 05903081 EONIS 17 06 2014 5 Advanced operation 5 10 Self calibration frequency About self calibration The front sensor of your Eonis display measures the output luminance of your screen and allows the display to automatically stabilize its luminance for maximum image quality over the displays lifetime This self calibration is done at an adjustable predefined frequency 1 1hr 6hr 24hr Never QAWeb This setting will be automatically selected when the self calibration frequency is defined by MediCal QAWeb To adjust the self calibration frequency 1 Bring up the OSD main menu 2 Navigate to the Adjustments gt Settings menu 3 Enter the Self Calibration Frequency submenu 4 Select one of the available frequency presets 5 11 Factory reset About factory reset A factory reset allows you to fully restore the display to its original factory setting To perform a factory reset 1 Bring up the OSD main menu 2 Navigate to the Adjustments gt Settings menu 3 Enter the Factory Reset submenu 4 Select Yes or No as desired and confirm K5903081 EONIS 17 06 2014 19 5 Advanced operation 20 K5903081 EONIS 17 06 2014 6 Maintenance 6 MAINTENANCE General maintenance inf
23. e wood ESD 8kV air 8kV air concrete or ceramic tile IEC 61000 4 2 E If floors are covered with synthetic material the relative humidity should be at least 3096 Electrical fast 2kV for power supply 2kV for power supply Mains power quality transient burst lines lines should be that of a typical IEC 61000 4 4 1kV for input output 1kV for input output eOmmercial or hospital lines lines environment Surge 1 kV line s to line s 1 kV line s to line s power quality IEC61000 4 5 2kVline s to earth 2 kV line s to earth 81009 be that of a typical commercial or hospital environment Test levels Voltage dips short lt 5 gt 95 dip lt 5 gt 95 dip in Mains power quality interruptions and voltage for 0 5 cycle Ur for 0 5 cycle should by that of a variations on power 5 5 Dr EX typical commercial or supply input lines eee Osa IDA Oy hospital environment If for 5 cycles for 5 cycles the user of the Eonis ee oi 70 30 dip in Ur 70 U 30 dip in requires continued for 25 cycles for 25 cycles operation during power A ban ait 6 a E mains interruptions it is 22 ua dip in recommended that the E T Eonis be powered from an uninterruptible power supply or a battery Power frequency 50 60 Not applicable Power frequency Hz magnetic field magnetic fields should IEC 61000 4 8 be at levels characterist
24. es and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the Eonis is used exceeds the applicable RF compliance level above the Eonis should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as re orienting or relocating the Eonis 4 Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m K5903081 EONIS 17 06 2014 29 Z Important information s These guidelines may not apply in all situations Electromagnetic propagation is af fected by absorption and reflection from structures objects and people Recommended separation distance The Eonis is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer of the user of the Eonis can help prevent electromagnetic interference by main taining a minimum distance between portable and mobile RF communications equipment transmitters and the Eonis as recommended below according to the maximum output power of the communications equipment Rated maximum output Separation distance according to frequency of transmitter power of transmitter 5 I50kHz to 80MHz 80MHz to 800MHz 800MHz to 2 5GHz 4 d 2
25. fecting the performance of the product To ensure optimal product quality Barco applies strict selection criteria for its LCD panels To learn more about LCD technology and missing pixels consult the dedicated white papers available at www barco com healthcare Maximize quality assurance QAWeb guarantees optimum and stabilized image quality in every private practice The front sensor on the Eonis works seamlessly with QAWeb to ensure a consistent image over time It automatically stabilizes the image from the moment you switch on the display What s more QAWeb provides you with instant feedback on the status of the display K5903081 EONIS 17 06 2014 _ 13 4 Daily operation 4 2 On Off switching To switch your display on or off 1 Shortly press the Standby key 4 3 Bringing up the OSD menus About the OSD menu The OSD menu allows you to configure different settings to make your Eonis display fit your needs within your working environment Also you can retrieve general information about your display and its current configuration settings through the OSD menu To bring up the OSD menu 1 While the display is switched on press the Menu Enter 9 key As a result the OSD main menu comes up in the middle of the screen If no further actions are taken within the following 10 seconds however the OSD menu will disappear again 4 4 Navigating through the OSD menus To navigate through the OSD menus 1
26. her where n is the limiting number o r Indicates that the box should be carried with two persons Indicates that the box should not be cut with a knife a cutter or any other sharp object n Indicates the temperature limits to which the device can be safely exposed when being stored Indicates the range of humidity to which the device can be safely exposed when being stored iP Indicates the range of atmospheric pressure to which the device be safely exposed when being stored xxkPa 7 Values for xx and yy can be found in the technical specifications paragraph 2 5903081 EONIS 17 06 2014 7 Important information 7 6 Legal disclaimer Disclaimer notice Although every attempt has been made to achieve technical accuracy in this document we assume no responsibility for errors that may be found Our goal is to provide you with the most accurate and usable documentation possible if you discover errors please let us know Barco software products are the property of Barco They are distributed under copyright by Barco N V or Barco Inc for use only under the specific terms of a software license agreement between Barco or Barco Inc and the licensee No other use duplication or disclosure of a Barco software product in any form is authorized The specifications of Barco products are subject to change without notice Trademarks All trademarks and registered trademarks are prope
27. ic of a typical location in a typical commercial or hospital environment Conducted RF 3 Vrms 3 V Portable and mobile IEC 61000 4 6 150 kHz to 80 MHz RF communications 1 is the a c mains voltage prior to application of the test level 2 Eonis doesn t contain susceptible components to magnetic fields 28 5903081 EONIS 17 06 2014 7 Important information Immunity test IEC 60601 Compliance level Electromagnetic environment guidance Radiated RF 3 V m equipment should be used no closer to IEC 61000 4 3 80 MHz to 2 5 GHz any part of the Eonis including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance 1 2 P d 1 2 P 80 MHz to 800 MHz d 2 3 VP 800 MHz to 2 5 Ghz Where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is the recommended separation distance in meters m Test levels Field strengths from fixed RF transmitters as determined by an electromagnetic site survey should be less than the compliance level in each frequency 4 Interference occur the vicinity of equipment marked with symbol Cp At 80 MHz and 800 MHz the higher frequency range applies 3 Field strengths from fixed transmitters such as base stations for radio cellular cordless telephon
28. ing up the OSD main menu K5903081 EONIS 17 06 2014 _ 17 5 Advanced operation 2 Navigate to the Adjustments gt Settings menu 3 Enter the Language submenu 4 Select one of the available languages 5 8 Power status LED About the power status LED By default the power status LED has the following behavior Green Display is on Blinking green Display is entering standby power saving mode Orange Display is in standby power saving mode Off Display is disconnected from the mains power This default behavior can be changed so that the power status LED is also off when the display is on or when the display is entering standby power saving mode To change the behavior of the power status LED 1 Bring up the OSD main menu 2 Navigate to the Adjustments gt Settings menu 3 Enter the Power Status LED submenu 4 Change the behavior of the power status LED as desired and confirm orange standby power saving state of the LED is not influenced by this setting So when the display is in standby power saving mode the LED will turn orange even if it was switched off by this setting 5 9 DPMS mode About DPMS mode Enabling the Display Power Management System DPMS mode on your Eonis display will optimize the displays lifetime by automatically switching off the backlight when no video signal is detected for approx imately 10 seconds The power status LED will then turn orange To enabl
29. is product please contact your local city office or your municipal waste disposal service For details please visit the Barco website at http www barco com en AboutBarco weee Turkey RoHS compliance T rkiye Cumhuriyeti AEEE Y netmeli ine Uygundur Republic of Turkey In conformity with the WEEE Regulation rh E X hii ROHS Chinese Mainland RoHS TR iis rh E lt Bh FE PL P 35 rh SLE ROHS 758121 T rh n B GI BL SA sk 8 BtJ 28 rh E RHS fR 4 815 E DBs BP EHE RU rh BJ S S s H According to the China Administration on Control of Pollution Caused by Electronic Information Products Also called RoHS of Chinese Mainland the table below lists the names and contents of toxic and or hazardous substances that Barco s product may contain The RoHS of Chinese Mainland is included in the MCV standard of the Ministry of Information Industry of China in the section Limit Requirements of toxic substances in Electronic Information Products 35 t 8 5 F ABAS JU xs and elements AGE RoR Cr6 P Printed Circuit Assemblies En d ME LCD panel 7H ER 2 Bt External Cables EID Internal wiring E Metal enclosure K5903081 EONIS 17 06 2014 25 Z Important information 4 B 6 F A gt Component
30. ish French German Spanish Italian Dutch Japanese Traditional Chinese Simplified Chinese Korean Dimensions with stand W x H 560 4 x 533 x 166 35 mm x D Dimensions w o stand W x H 560 4 x 366 x 61 72 mm x D Dimensions packaged W x H 481 x 273 x 761 mm x D Net weight with stand 9 5 kg Net weight w o stand 6 17 kg Net weight packaged with 13 5 kg stand nell adjustment range 100 5 0 mm n Heer M TS Pet es Mounting standard VESA 00 mm creen protection Protective non reflective glass cover K5903081 EONIS 17 06 2014 __ 35 7 Important information 36 CE MDD 93 42 EEC class product CE 2004 108 EC IEC 60601 1 ED 3 ANSI AAMI ES 60601 1 2005 1 2009 5 22 2 No 60601 1 1 08 2008 DEMKO EN 60601 1 1 2006 EN 60601 1 2 2007 KC VCCI FCC class B ICES 001 Level B FDA Class device RoHS Cable routing strap Video cables 1 x VGA 1 x HDMI 1 x DP Main cables UK European CEBEC KEMA or USA UL CSA adaptor plug NEMA 5 15P USB 2 0 cable This adapter s is a forming part of the medical device Manufacturer BridgePower Corp model 060512 03 Input 100 240 V 50 60 Hz 1 5 A Output 12V DC 5 0 A QA software QAWeb Private Practice QAWeb 1 12x Operating temperature 10 35 C software Storage amp transport 20 C 60 C temperature Operating humidity 10 90
31. me 1 WELCOME 1 1 About the product Consistent image quality The Eonis display presents crisp razor sharp high contrast images To guarantee image consistency at all times it features a unique front sensor that automatically aligns image quality every time the display is turned on This image consistency enhances collaboration images always appear exactly like they are supposed to on every display which spurs confident clinical decisions Furthermore specialists looking at X ray images will appreciate the built in DICOM settings One click quality assurance Like Barco s entire medical display range the Eonis display line comes with Barco s online MediCal service for quality assurance and remote asset management Proving its superior value in hospitals around the world MediCal QAWeb provides automated quality assurance checks and detailed reports It makes it easy for healthcare IT to centrally and remotely manage and configure displays across the healthcare organization Also for private practices QAWeb further strengthens image consistency and allows you to easily personalize your image Fully cleanable and smart design The Eonis display carries all safety certifications required in clinical environments It features an inte grated cable management system making it safe to use in hospitals and private practices The multi ple mounting options and connections further add to the smart design typical of Barco s
32. nnecting disconnecting any cables to from the display K5903081 EONIS 17 06 214 9 10 3 Display installation Image 3 6 3 7 VESA mount installation To mount the display on a VESA arm The display panel standard attached to a stand is compatible with the VESA 100 mm standard 1 Put the display face down on a clean and soft surface Be careful not to damage the panel screen 2 Unscrew the four fixation screws to detach the panel from the stand 3 Use 4 4 screws to attach the panel to a VESA approved arm Please make sure that the length of the screws is 10 mm VESA plate thickness tolerance of 0 5 mm Image 3 7 CAUTION Use arm that can support a weight of at least 12 kg 26 50 Ibs Failure to do so could make the panel fall causing serious injury to a child or adult and serious damage to the equipment CAUTION Never move a display attached to an arm by pulling or pushing the display itself Instead make sure that the arm is equipped with a VESA approved handle and use this to move the display Please refer to the instruction manual of the arm for more information and instructions K5903081 EONIS 17 06 2014 3 Display installation CAUTION Use suitable mounting apparatus to avoid risk of injury K5903081 EONIS 17 06 2014 11 3 Display installation 12 _ 5903081 EONIS 17 06 2014 4 Daily operation 4 DAILY OPERATION 4 1 Recommen
33. nu 2 Navigate to the Adjustments menu 3 Enter the Luminance submenu 4 Set a luminance value as desired and confirm 5 3 Gamma selection About gamma selection Native uncorrected panels will display all grayscale color levels with equal luminance increments Studies have shown however that in medical images certain grayscale color parts contain more relevant informa tion than others To respond to these conclusions gamma functions have been defined These functions emphasize on these parts containing crucial information by correcting the native panel behavior The available gamma functions for your display are K5903081 EONIS 17 06 2014 15 5 Advanced operation Native If you select Native the native panel behavior will not be corrected sRGB This is the display function as defined in the sRGB specification and is designed to match typical home and office viewing conditions It is widely used in most computer applications e DICOM DICOM Digital Imaging and Communications in Medicine is an international standard that was developed to improve the quality and communication of digital images in radiology In short the DICOM gamma function results in more visible grayscales in the images Barco recommends selecting the DICOM gamma function for most medical viewing applications Gamma 2 2 Select this function in case the display is to replace a CRT display with a gamma of 2 2 QAWeb This gamma function will
34. oid the risk of electric shock this equipment must only be connected to a supply mains with protective earth The equipment should be installed near an easily accessible outlet The equipment is intended for continuous operation Transient over voltage If the device is not used for a long time disconnect it from the AC inlet to avoid damage by transient over voltage K5903081 EONIS 17 06 2014 _ 23 7 Important information 24 To fully disengage the power to the device please disconnect the power cord from the AC inlet Power cords Do not overload wall outlets and extension cords as this may result in fire or electric shock Mains lead protection U S Power cord Power cords should be routed so that they are not likely to be walked upon or pinched by items placed upon or against them paying particular attention to cords at plugs and receptacles The power supply cord should be replaced by the designated operator only at all time Usea power cord that matches the voltage of the power outlet which has been approved and complies with the safety standard of your particular country Grounding reliability Grounding reliability can only be achieved when the equipment is connected to an equivalent receptacle marked Hospital Only or Hospital Grade External equipment External equipment intended for connection to signal input output or other connectors shall comply with relevant UL EN IEC standard e
35. ormation The Eonis does not require any scheduled maintenance or calibration activities We recommend to use QAWeb with the Barco default tests and frequencies to calibrate and maintain the display or return the display to a Barco approved maintenance organization In any case of doubts contact the Barco Health care Division 6 1 Cleaning instructions To clean the display Clean the display using a sponge cleaning cloth or soft tissue lightly moistened with plain water Do not use following products Alcohol solvents at higher concentration gt 5 Strong alkalis lye strong solvents Acid Detergents with fluoride Detergents with ammonia Detergents with abrasives Steel wool Sponge with abrasives Steel blades Cloth with steel thread CAUTION Take care not to damage or scratch the front glass or LCD Be careful with rings or other jewelry and do not apply excessive pressure on the front glass or LCD CAUTION Do not apply or spray liquid directly to the display as excess liquid may cause damage to internal electronics Instead apply the liquid to a cleaning cloth K5903081 EONIS 17 06 2014 __ 021 6 Maintenance 22 K5903081 EONIS 17 06 2014 7 Important information 7 IMPORTANT INFORMATION 7 1 Safety information General recommendations Read the safety and operating instructions before operating the device Retain safety and operating instructions for future reference A
36. rty of their respective owners Copyright notice This document is copyrighted All rights are reserved Neither this document nor any part of it may be reproduced or copied in any form or by any means graphical electronic or mechanical including photocopying taping or information storage and retrieval systems without written permission of Barco 2014 Barco All rights reserved 7 7 Technical specifications MDRC 2224 BL Screen technology Color LCD IPS Resolution 2 1920 x 1200 Pixel pitch 0 270 Calor imaging Gray imaging Yes Color support 10 bit Ambient Light Compensation Yes preset values in OSD ALC es Maximum luminance 300 cd m typical DICOM calibrated luminance 180 cd m Contrast ratio 1000 1 typical Response time Tr Tf 14 ms typical Housing color Black Silver Video input signals VGA DisplayPort HDMI USB ports 1 upstream 2 downstream K5903081 EONIS 17 06 2014 __ 33 7 Important information Power requirements nominal 100 240 V ower consumption nominal 40 W 1 0 W in stand by ower save mode ower management Dot clock OSD languages English French German Spanish Italian Dutch Japanese Traditional Chinese Simplified Chinese Korean Dimensions with stand W x H 560 4 x 533 x 164 45 mm Dimensions w o stand W x H 560 4 x 366 x 59 82 mm Dimensions packaged W x H 481 x 273 x 761 mm Net weight with stand 38 kg Net weight w o
37. stand kg Net weight packaged with 12 38 kg stand Height adjustment range 100 5 0 mm 5 J 5205 45 45 Certifications MDD 93 42 EEC class product CE 2004 108 EC IEC 60601 1 ED 3 ANSI AAMI ES 60601 1 2005 1 2009 CAN CSAC22 2 No 60601 1 1 08 2008 DEMKO EN 60601 1 1 2006 EN 60601 1 2 2007 KC VCCI FCC class B ICES 001 Level B FDA Class device RoHS Supplied accessories User Guide Cable routing strap Video cables 1 x VGA 1 x HDMI 1 x DP Main cables UK European CEBEC KEMA or USA UL CSA adaptor plug NEMA 5 15P USB 2 0 cable This adapter s is a forming part of the medical device Manufacturer BridgePower Corp model 060512 03 Input 100 240 V AC 50 60 Hz 1 5 A Output 12V DC 5 0 A Storage amp transport humidity 5 90 non condensing at 39 deg ambient Operation altitude 3000 m torage amp transport altitude 5500 m Operating pressure 70 kPa 106 kPa torage amp transport pressure 50 kPa 106 kPa 34 5903081 EONIS 17 06 2014 7 Important information MDRC 2224 WP Resolution 2 1920 x 1200 Pixel pitch 0 270 Color maging Gray imaging Yes Color support 10 bit Viewing angle H V We ew Ambient Light Compensation ss preset values in OSD ALC 5 sensor el luminance Goo ciegas _ cd m typical DICOM calibrated luminance 180 cd m Contrast ratio 1000 1 typical Dodxk fow Engl
38. u use an unstable cart or stand the device may fall causing serious injury to a child or adult and serious damage to the device This apparatus conforms to CE MDD 93 42 EEC class product CE 2004 108 EC IEC 60601 1 ED 3 ANSI AAMI ES 60601 1 2005 C1 2009 CAN CSAC22 2 No 60601 1 1 08 2008 DEMKO EN 60601 1 1 2006 EN 60601 1 2 2007 KC VCCI FCC class B ICES 001 Level B FDA Class device RoHS National Scandinavian Deviations for CL 1 7 2 Finland Laite on liitettava suojamaadoituskoskettimilla varustettuun pistorasiaan Norway Apparatet m tilkoples jordet stikkontakt Sweden Apparaten skall anslutas till jordat uttag K5903081 EONIS 17 06 2014 7 Important information 7 22 Environmental information Disposal Information Waste Electrical and Electronic Equipment mmmmH This symbol on the product indicates that under the European Directive 2012 19 EU governing waste from electrical and electronic equipment this product must not be disposed of with other municipal waste Please dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources For more information about recycling of th