1. Satellite input Cable output TV output L O frequency Invert Spectrum Inversion RF Channel Input Frequency Modulation RF Level Symbol Rate Antenna Diseqc Symbol rate auto DVB Mode 2 Auto This option allows saving and loading the configuration of the module in the PRO 201 programmer Roll off factor Symbol speed 12 TSQ 310 version_en_1 1 User s manual TSQ 310 Read from module It stores the current configuration of the module in the memory of the programmer The steps to make a correct reading of the headend are specified below ar o gt Read from Module Write to Module Too 1O Too iO Operation finish 1 Select the option Read from module through Up Down buttons Press OK to continue Free position 2 Select the position of CFG memory where you wish to save the current contiguration of the module 3 A window will appear and it will let you know that the reading made has been correct Write to module It loads in the module one of the configurations previously saved in the memory of the programmer The steps to make a correct configuration of the headend are specified below Poor LO gt Write to Module Read from Module 1 Select the option Write to module through Up Down buttons Press OK to continue 3 Contig TSO O CHG 01 Sree rou Freq 850000 Freq 11362 Out pwr 2 Select the position of the
2. Band spurious 60 dBc Programming Interface RJ 45 Programmer PRO 201 media Max EVO and media Max MINI Operating temperature 0 C 45 C Consumption 5V mA 800 Consumption 12V mA 300 Consumption 24V mA 15 Consumption 30V mA 2 Dimensions 75x265x150 mm Weight 1 4Kg Chapter 3 Declaration of conformity CONFORMITY DECLARATION WE FTE MAXIMAL DECLARE THAT THE PRODUCT TSQ 310 IS IN CONFORMITY WITH FOLLOWING DIRECTIVES Low Voltage Directive 2006 95 EC EMC Directive 2004 108 EC If you wish a copy of the conformity declaration please contact to the company 16 TSQ 310 version_en_1 1 FTE maximal
3. OAM Roll off factor Roll off factor reduces the interference between symbols thanks to the raised cosine filtering the bigger this value is the less interference between symbols that will be caused Typical Value according to rules DVB C 15 Options 1 5 1 3 Symbol speed The available symbol speed ranges from 1000 to 7000 S s In order to estimate the output symbol speed you have to take into account the following parameters input modulation input symbol speed input FEC output modulation For example for a 8PSK signal with 22000 MS s and a FEC 2 3 the output symbol speed should be calculated according to the chosen QAM modulation VoymBoL y FECAn bit symbol 8PSK 22000 vA 3 P _ SIMBOLIN fo VUNA T a SYMBOL OUT n bit symbol QAM n bit symbol QAM 256 QAM symbol Modulation 16 QAM 32 QAM 64 QAM 128 QAM 256 QAM Symbol speed MS s 11000 8800 1333 6286 5500 Output configuration TV output In these options you can configure the output parameters of the terrestrial signal RF Channel MHz Output frequency of terrestrial modulation In order to introduce the frequency press the OK button and the cursor will be placed over the frequency With the keys of the cursor we can move through all the digits and change the values Press OK in order to save the value Options 47 862 MHz RF Level Regulation of the output level of the modulated signal Options O 15dB Summary table
4. With the keys of the cursor we can move through all the digits and change the values Press OK in order to save the changes Note If in the existing installation there are already services that have LNC system you will have to configure the position of the module services in order to avoid conflicts with other net services Date Hour Setting of the date and time of transmodulator It is appropriate to maintain these parameters set in order to have the registration of errors linked to the current time and date SW version info It allows you to visualize the basic information of the module model firmware version etc Global Update It allows carrying out the update of all the modules that are interconnected at the same time 14 TSQ 310 version_en_1 1 FTE maximal User s manual TSQ 310 1 5 Accessories and example of installation Example of installation Installation that consist of 6 TSQ 310 and that will allow tuning OS 100 A channels up to 6 different transponders and to distribute them ieri i through a network of modulated cable in DVB C The p Diaa ay distributed channels need a cable receiver in order to be Baa decoded in this case we propose a PVR C130 CI HDMI receiver that would decode free channels and also encoded channels if we insert a PCMCIA with the corresponding AMP 310P subscriber card _ TSQ 310 PVR C130 Cl HOMI PVR C130 Cl HOMI en x PVR C13
5. of modules Delete program It allows deleting a program Device to process Current The creation or loading of a program will be applied only in the module that is currently connected All The creation or loading of a program will be applied to the whole group of connected modules Working disk With this option we have the possibility of choosing if we want to work into the internal disk or in the external storage device USB 2 0 Once the option is selected a dialog box will appear and we will be able to choose among three different options Auto The Meter decides where the data will be stored If there is external memory connected the Meter will store the data in it If not it will use the internal memory USB The Meter always will try to use the external memory connected to the USB port If this memory has not been connected an error message will be shown reminding that there was an error storing the data and it will be not stored Internal Always the internal memory is used to store the data Load programs from USB This option allows importing programs from a USB memory to the field strength meter Before using this option you must connect a USB memory Save programs to USB This option allows copying the programs stored in the external USB 2 0 storage device Write Alias It allows saving the alias of the module in the program Options Yes No 8 Set Output Services This option allows making the selection of the
6. services that you wish to include in the output multiplex Add Remove services It allows adding the services to the multiplex and also removing the ones previously included The lower bar informs about the available space in the output multiplex As you add more services the space available will decrease Once you have tuned a transponder in the Input Set Up section and you have selected the DVB C modulator configuration in the Modulator Set Up section you can make the assignment of the services that are going to be included in the output multiplex Adding Removing services 8 TSQ 310 version_en_1 1 FTE maximal User s manual TSQ 310 Adding services 1 Select Service to add option 2 Select one of the transponder 3 Once you have chosen the services you want to add service select the Add Remove button to include the service in the multiplex variability of the bits rate of the inputs services Excessive capacity f Note It is not recommended to exceed the 85 of the maximum capacity of the multiplex due to the possible Recomendad capacity Itis recommended to remove lower to 85 l services Removing services 1 Select the Service to remove 2 Select one of the transponder 3 Once you have chosen the option services you want to remove service select the Add Remove button to remove the service in the multiplex 9 TSQ 310 version_en_1 1 FTE maximal Use
7. 01 programmer you can only carry out the programming of a single module in order to carry 1 Manual Inside the manual menu there are specified the different options for setting up the input output and modulation parameters 1 1 This field shows the type of parameter that is selected at the moment Options Input Sat Out Cab Out TV 5 2 This field shows the parameter that is selected In order to move around the different options we have to use the Up and Down buttons of the keyboard Click on OK to edit the selected parameter and Right Left for changing it Once it is configured press OK Satellite input Input Sat In these options you will be able to configure the input parameters of the satellite signal LO freq Local oscillator Selection of the local oscillator that you wish to use Fl KU C K9 750 K10000 K10600 K10700 K10750 K11250 K11300 K11325 Freq Input Frequency MHz Transponder frequency that you wish to tune In order to introduce the frequency press the OK button and the cursor will be placed over the frequency With the keys of the cursor we can move through all the digits and change the values Press OK in order to save the value Symbol Rate Symbol speed required by the transponder In order to introduce the symbol rate press the OK button and the cursor will be placed over the frequency With the keys of the cursor we can move through all the digits and cha
8. 20 Cl HDMI PVR C130 CI HOMI L L a a a PVR C130 Cl HDMI PWR C130 Cl HDMI DISTRIBUTION NETWORK installation we recommend you to provide the inputs and outputs which are not used with a 75Q load In order to guarantee the right running of the different equipments of the Accessories OUT Programmer Field strength meter Field strength meter Mod PRO 201 Mod mediaMAX EVO S2 Mod mediaMAX MINI S2T Code 2003123 Code 3001006 Code 3001026 B Ry Fi Parabolic antenna OS series Wide band amplifier 47 862MHz Mixer Mod OS 100 AL Mod AMP 310 P Mod MUX 310 Code 0701100 Code 2003520 Code 2003518 15 TSQ 310 version_en_1 1 FTE maximal User s manual TSQ 310 Chapter 2 Technical features Ref TSQ 310 Code 2003532 Input frequancy margin 950 2150 MHz Input level 25 a 65 dBm Imput impedance 750 LNB feeding conmutation 13V 18V 0 22kHz Input connector Female F connector Input LOOP losses lt 1 dB FEC 1 2 2 3 3 4 5 6 7 8 8 9 9 10 174 1 3 1 5 2 5 3 5 4 5 DVB RS 204 188 Input modulation 8PSK QPSK Input Symbol Rate DVB S 1 45 MS s DVB S2 1 37 MS s Modulation Error Ratio MER Typ 40 Min 36 Selectable format of output modulation 16 QAM 32 QAM 64 QAM 128 QAM 256 QAM Output symbol Rate 1 6 96 MS s Roll Off Factor 13 15 Output channels C2 C69 Output connectores Female F connector Output Level 80 dBuV Regulation margin 15 dB MIX Losses lt 1 dB
9. 28 QAM 256 QAM Roll off factor Roll off factor reduces the interference between symbols thanks to the raised cosine filtering the bigger this value is the less interference between symbols that will be caused Typical Value according to rules DVB C 15 Options 15 13 5 Output configuration In this option you can configure the different parameters of the cable signal Channel standard It allows you to select the channelling of the cable signal standards Options BG BG PAL BG IT 11 M NTSC PAL M PAL N PAL DK PAL BB_AU DK PAL L PAL Channel Output channel of the cable modulation When you select the output channel the field Frequency MHz will be modified automatically adapting itself to the selected channel Options C2 C69 Frequency MHz Output frequency of cable modulation When you modify this field the field Channel will be also modified indicating the channel equivalent to the selected frequency in the case that this frequency corresponds to the frequency of a channel Options 47 862 MHz Level Regulation of the output level of the modulated signal Options O 15dB Calibration Allows the realization of two tests in order to verity the correct running of the device Output deactivate It allows activating or deactivating the output of transmodulator Pure carries output It allows activating or deactivating the DVB C modulation allowing visualizing the carrier withou
10. BER before and after Viterbi It indicates the error rate of bits of the input signal before and after the correction produced by Viterbi algorithm MER Parameter that indicates the quality of the input modulated digital signal expressed in dB Noise Margin It indicates the difference between the value of current C N and the value of C N at the point of pixilation of the signal that is the quantity of dBs of C N measure that are needed to lose the input signal Temperature It indicates the current temperature of the module in C 3 Input contiguration In this option you will be able to configure the input parameters of the satellite signal Local oscillator Selection of the local oscillator that you wish to use Fl KU C K9750 K10000 K10600 K10700 K10750 K11250 K1 1300 K11325 Frequency MHz Transponder frequency that you wish to tune Symbol speed Symbol speed required by the transponder Auto symbol rate You will be able to select if the detection of the Symbol Rate is going to be Automatic On or Manual Off In Manual mode Off the value of the Symbol Rate should be fixed by the user based on the provider s information In Automatic mode On the meter will automatically identify the SR when a Satellite carrier is tuned This feature is very useful when the provider s information is unknown The SR value found will appear in the field of selection of the SR menu This value found by the meter coul
11. CFG memory that you wish to copy in the module Please verity that the data of the selected memory correspond to the channel that you wish to copy In Config option the information concerning the transmodulator is given Read log It allows reading the registered events in the module T3020 LCN gt Read LOG file Delete LOG file 1 Select the option Read LOG file through Up Down buttons Press OK to continue T0210 Ok to Show LOG 2 Press OK again to show the log file Delete LOG file It allows deleting all events stored until this moment Factory default This option restores the values by default of the transmodulator Update FW It allows carrying out the firmware update from the programmer Output services This option allows making the selection of the services that you wish to include in the output multiplex Once you have tuned a transponder and you have selected the DVB T DVB H modulator configuration you can make the assignment of the services that are going to be included in the output multiplex Adding Removing services 13 TSQ 310 To o e Operation finish 3 A window will appear and it will let you know that the configuration made has been correct TSO 210 LCN gt Read LOG file Delete LOG file ESOTO WeO00001 07702711 Front end jock Status Us Poss sO2 3 A new window will appear It will show the information about the registered events in the m
12. User s manual TSQ 310 NOTE This users guide is adapted to software version OOOA 0003 of TSQ 310 dated 18 10 2010 For future software updates you can download the users guide from the following website http www ftemaximal com Chapter 1 Installation 1 1 Safety Measures 1 Never place the device next to hot sources 2 Never undergo the device to temperatures that exceed its level of operation 3 Never expose the device to leakings nor spatterings 4 Never place objects that contain liquids over the device 5 Respect the ventilation slots of the device do not cover them with any kind of object 6 The space around the device must be free of objects in a minimum radius of 40cm 7 Avoid locations with possibilities of spilling liquids on the inside of the device and with important changes of temperature 8 Never open the device by yourself due to electric risk In case of problems go always to qualified technicians 9 Never under no circumstances open the device when connected to the electrical net 10 During the handling it is better to disconnect the device from the electrical net 11 Obey the electricity security rules during the assembling Use materials that obey the current law 12 The connecting plug must be accessible in a fast and simple way to have a fast disconnection 13 Never touch the plug with wet hands Also disconnect always the device before handling the connections 14 Never put any heavy
13. current time and date Set date time all devices Loading the current date and time of the module in the rest of interconnected modules Alias Write alias It allows you to assign a name alias to the module you are programming Option only available when the Alias Auto option is configures as none manual mode Auto Alias It allows configuring the name alias of the modules automatically Options Channel Frequency Service None Upgrade Send Firmware from USB It allows carrying out the firmware update from the USB device Send firmware to all It allows carrying out the update of all the modules that are interconnected at the same time 7 TSQ 310 version_en_1 1 FTE maximal Users manual TSQ 310 Configure all devices Input values to all devices It allows copying the current input configuration in all the interconnected modules Modulator values to all devices It allows copying the configuration of the current modulator in all the interconnected modules Output values to all devices It allows copying the current output configuration in all the interconnected modules Factory default to all devices It allows making values by default to all the interconnected modules T Program management New program This option allows creating a program with the current configuration of a module or group of modules Load program It allows loading a previously created program on a module or group
14. d not correspond exactly to the real broadcast SR but to a very close value Note The Automatic Symbol Rate feature does not work when the carrier quality is very poor or and with a very low Power Level DVB This option allows selecting the standard DVB of the transponder that you want to tune Options DVB S1 DVB S2 and auto LNB Feeding In this option you can set the parameters concerning the LNB Voltage RF IN 13V 18V and Off Tone 22 kHz Off and Auto In the Switch DiseqC A B C D and Off 5 TSQ 310 version_en_1 1 FTE maximal User s manual TSQ 310 4 Modulator configuration This option allows you to configure the DVB C modulator that the device has Symbol speed The available symbol speed ranges from 1 to 6 96 MS s In order to estimate the output symbol speed you have to take into account the following parameters input modulation input symbol speed input FEC output modulation For example for a 8PSK signal with 22000 MS s and a FEC 2 3 the output symbol speed should be calculated according to the chosen QAM modulation VoymBoL n FECAn bit symbol 8PSK 22000 vA 3 SYMBOL OUT n bit symbol QAM n bit symbol QAM symbol Modulation 16 QAM 32 QAM 64 QAM 128 QAM 256 QAM Symbol speed MS s 11000 8800 7333 6286 5500 Spectrum inversion Activate or deactivate the spectrum inversion in the modulation Modulation Modulation Format Options 16 QAM 32 QAM 64 QAM 1
15. indicates the different states of the device 2 OUT This connector supplies the modulated channel according to the selected standard in the module and mixes it with all the signals that it receives throught the MIX connector 3 MIX Input of mixing of the module 4 LNC IN To connect to the LNC or to the LOOP OUT output of the previous amp a module 4 5 LOOP OUT To connect to the ANT IN input of the next module a 6 RS 232 Ethernet connector to cascade modules with the RCM 310 telecontrol unit with the RJ45 RJ45 cable provided 7 PRO 201 Ethernet connector to make the programming with the programmer 8 DC connectors It has two connectors for input output Fen fol 7 Sh Voksen TS 310 ver Fte States of two colored leds 1 Initialization mode Green main application charged Blinking Green Completing the initial sequence at the moment when the module gets initialized the led will turn into one of the states the operating mode Red Phase of initializing the module 2 Operative Mode Green The system is working properly Orange At least one critical event has been recorded in the module The led will only change into green when the registration of events has been read by the programmer Red Error or alert detected in the running of the device the led will be on only as long as the error alert is present Once the error or the alert disappears the led will change into orange because the er
16. nge the values Press OK in order to save the value Antenna Feeding tone towards the LNC Options OV 13V 138V 22kHz 18V 18V 22KHz 13V AUT 18V AUT DiseqC In this option you can set the DiseqC configuration A B C D and None Auto SR Auto Symbol Rate You will be able to select if the detection of the Symbol Rate is going to be Automatic On or Manual Off In Manual mode Off the value of the Symbol Rate should be fixed by the user based on the provider s information In Automatic mode On the meter will automatically identify the SR when a Satellite carrier is tuned This feature is very useful when the provider s information is unknown The SR value found will appear in the field of selection of the SR menu This value found by the meter could not correspond exactly to the real broadcast SR but to a very close value Note The Automatic Symbol Rate feature does not work when the carrier quality is very poor or and with a very low Power Level Mode This option allows selecting the standard DVB of the transponder that you want to tune Options DVB S1 DVB S2 and auto 11 TSQ 310 version_en_1 1 FTE maximal User s manual TSQ 310 Cable modulator Out Cable This option allows you to configure the DVB C modulator that the device has Spectrum inversion Activate or deactivate the spectrum inversion in the modulation Modulation Modulation Format Options 16 QAM 32 QAM 64 QAM 128 QAM 256
17. object over the device since it could get damaged 15 If the device is going to remain some time without use it is recommendable to disconnect it from the electrical net 16 The repairmen and the maintenance of the device must be done by TV and radio specialised technicians 1 2 Box content Fte THO THO 7 TEO 0 7 TEF TEF TSP OLS TFF 7 TF ob ib a 5 d Quick installation guide 2 x Bridge F male F male DC Cable TSQ 310 Cable 12 cm PIN to PIN RJ45 RJ45 1 TSQ 310 version_en_1 1 FTE maximal User s manual TSQ 310 1 3 Description and connections The module TSQ 310 is used for the reception of free channels that obey the DVB S DVB S2 standards Each module allows the reception of a complete transponder in DVB S QPSK DVB S2 QPSK 8PSk and the subsequent modulation in DVB C QAM of it A feature of this equipment is its modulator in Vestigial Side Band or VSB This modulation can be used to distribute adjacent channels in one distribution without any intermodulation problem Each module has one Loop connector to cascade several modules at input and a Mix connector to do same in output channels The output channel is selectable between C2 and C69 All parameters are programmed by the means of PRO 201 or the EVO or MINI series of field strength meter and they are monitored in the display of programmer or in the 5 TFT screen of field strength meter TSQ 310 1 Two colored led It
18. odule Press the following keys in order to scroll up and down the screen up down version_en_1 1 FTE maxima User s manual TSQ 310 Add Services 1 Select the option Add services 2 Select one of the transponder 3 A window will appear and it will let through Up Down buttons Press OK services you want to add through you know that the operation made has to continue Left Right keys and select the Add been correct button to include the service in the multiplex Delete Services 1 Select the option Delete services 2 Select the service you want to 3 A window will appear and it will let through Up Down buttons Press OK delete with the Left Right keys Then you know that the operation made has to continue press OK over Rem in order to been correct remove it or press OK over All in order to delete all the services of the multiplex Note It is not recommended to exceed the 85 of the maximum capacity of the multiplex due to the possible variability of the bits rate of the inputs services LCN The LNC function allows assigning automatically a predetermined position to each one of the services of the multiplex This function will allow the users who have a receiver with LNC support to make the ordination of channels automatically Select a channel through Left Right buttons and introduce the position Press the OK button and the cursor will be placed over the number
19. ong as they are interconnected with each other through the RJ 45 cable supplied with each unit 3 TSQ 310 version_en_1 1 FTE maximal User s manual TSQ 310 1 4 2 Programming Below you will find the steps to follow in order to make the programming both from corresponding EVO and MINI field strength meter as well as from PRO 201 mediaMAX EVO mediaMAX MINI In order to start programming the TSQ 310 transmodulator you will have to go to Tools option through the key 8 of your field strength meter and to select the Prog Transmodulators option Then it will proceed to recognize the module and to show the main menu In the Prog Transmodulators are shown the different configuration options that this tool offers 1 Module selection The field strength meter allows carrying out the programming of one or several transmodulators from an only transmodulator Without interconnection of modules Interconnection of several modules you can select which An only module connected modules you wish to program 4 TSQ 310 version_en_1 1 FTE maximal Users manual TSQ 310 2 State of the module In the option State of the module are specified the main parameters of the module at this moment Transmodulator input It indicates whether the module is hooked or without signal Input bit rate Transfers of data in the satellite tuner input Output bit rate Transfer of data in the module output
20. ror alert is stored in the registration of events 3 Programming mode When the module detects an external programmer the led will blink in the next sequence green orange red Once you leave the programming mode the led will turn into the corresponding operating mode 2 TSQ 310 version_en_1 1 FTE maximal User s manual TSQ 310 Stages of transmodulator TSQ 310 Input DVE 5 OPSK DVB S2 8PSK QPSK 850 MHz 2150 MHz Selection of a tuned satellite transponder Y Transmodulation SERVICES FILTERING Service 5 Service 7 FTA Service 8 Service 9 FTA The tuned channels of the transponder are modulated according to the DVB C rules If the transponder has encoded channels the final user will need a receiver with Cl subscriber card or an encrypted channels receiver bA Out DVB C QAM 47 MHz B62 MHz Contiguration of the channels and output parameters 1 4 Programming TSQ 310 has two ethernet connectors In order to make the programming of the module you have to connect the corresponding programmer to PRO 201 connector You can make the programming through the PRO 201 programmer and also through the mediaMAX EVO and mediaMAX MINI field strength meter 1 4 1 Programming modes With mediaMAX EVO mediaMAX MINI field strength Through PRO 201 the programming is made module by meter you can carry out the programming of all the module modules consecutively as l
21. rs manual TSQ 310 Remove all services It allows removing all the services included in the multiplex Modify LCN The LNC function allows assigning automatically a predetermined position to each one of the services of the multiplex This function will allow the users who have a receiver with LNC support to make the ordination of channels automatically f Note If in the existing installation there are already services that have LNC system you will have to configure the position of the module services in order to avoid conflicts with other net services Bandwith limitation It allows selecting the of the capacity of the output channel Auto service addition On It selects the services automatically when an input carrier is tuned and when the list of selected services is empty The receiver will have this state by default Always It selects the services automatically every time a new input carrier is tuned This state is only recommended to be used for making test in the module Off The automatic mode is deactivated the services have to be manually selected Advanced settings Network It allows making the adjustment of the identification parameters of the multiplex TS ID Transport Stream identification value It is recommended to configure a value different from TS ID for each one of the output multiplex configured Net ID Net identification value Original Net ID Original net identification value Ne
22. t modulation in the selected frequency 6 TSQ 310 version_en_1 1 FTE maximal Users manual TSQ 310 6 System This option provides information of the transmodulator System logfile In this field are indicated the registered events in the module Read log It allows reading the registered events in the module Clear log It allows deleting all events stored until this moment Export log to USB It allows you to export all events registered to the connected USB device NM low Limit dB An event of error will be recorded when the value of Noise Margin is lower than the set value NM hight limit dB Once the event of error is recorded Noise Margin lt Limit Lower NM this will be Noise Margin value that will have to be exceed so the module stops being in error Clear log all devices It allows deleting the events report of all the interconnected modules Factory default This option restores the values by default of the transmodulator System information It allows you to visualize the basic information of the module model no of series firmware version etc Settings This option allows saving and loading the configuration of the module carrying out firmware update or making an adjustment of the time and date of the module Clock Set Date and time Setting of the date and time of transmodulator It is appropriate to maintain these parameters set in order to have the registration of errors linked to the
23. twork Name Name associated with the net Services Change service name It allows changing the name of the service manually In order to do so please choose the service in the first line and then write the new name in the second line Then you have to press modify in order to save the changes 10 TSQ 310 version_en_1 1 FTE maximal Users manual TSQ 310 Next it is attached the identification table NID ONID of the main satellites You will be able to find more information in the law ETSI TR 101 162 v1 2 1 Satellite Hotbird 13 E Eutelsat 13 E Astra 19 2 E Net ID 318 1 Original Net ID Eutelsat 13 E System Astra Satellite Network 19 2 E Hispasat 30 W Astra 23 E 3 25 3 25 Astra n n 1 23 Astra 28 2 E 2 2 Astra Satellite Network 28 2 E Nilesat 7 W 2048 2048 Nilesat 101 33 Hispasat Network 1 PRO 201 out the programming of several modules at the same time you have to use a mediaMAX EVO or mediaMAX MINI series field strength meter When you connect the PRO 201 programmer it will proceed to recognize the module and to show the main menu In the main menu are shown the different options for configuring the transmodulator We have to use the Up and Down buttons of the keyboard in order to move to the different options and to get into the submenus we have to press OK button Note From PRO 2