Home
Oregon Scientific EMR211 weather station
Contents
1. E FUL REFERENCE The optional sensor Model BTH Sensor can be purchased from Oregon Scientific PRECAUTIONS Do not subject the unit to excessive force shock dust temperature or humidity Do not cover the ventilation holes with any items such as newspapers curtains etc Do not immerse the unit in water If you spill liquid over it dry it immediately with a soft lint free cloth Do not clean the unit with abrasive or corrosive materials Do not tamper with the unit s internal components This invalidates the warranty Only use fresh batteries Do not mix new and old batteries Images shown in this manual may differ from the actual display When disposing of this product ensure it is collected separately for special treatment and not as household waste Placement of this product on certain types of wood may result in damage to its finish for which Oregon Scientific will not be responsible Consult the furniture manufacturer s care instructions for information e The contents of this manual may not be reproduced without the permission of the manufacturer e Donotdispose old batteries as unsorted municipal waste Collection of such waste separately for special treatment is necessary e Please note that some units are equipped with a battery safety strip Remove the strip from the battery compartment before first use NOTE The technical specifications for this product and the contents of the user manual are subj
2. NTIFIC es TEM PI OUT Sb Cb mo DW ln JIL H eee ICE ALERT WN NO of 1 Outdoor temperature reading C F 2 Sensor channel indicator ae Ee be d Sensor reception indicator CC outdoor remote sensor battery low Indoor temperature reading C F E indoor remote sensor main unit battery low BLE connection indicator Ice alert LED indicator 1 2 3 4 SET select temperature unit C F pair up Bluetooth function A select outdoor channels 1 5 search remote sensor W select outdoor channels 1 5 auto scan among sensors RESET reset the unit to default settings Battery compartment LED status indicator Wall mount hole Battery compartment RESET hole CHANNEL switch REFERENCE Other supported sensors include models THGN328N THGR328N BTH sensor THN318N GETTING STARTED 1 Remove the battery compartment 2 Insert the batteries matching the polarities 3 Press RESET after each battery change __ LOCATION MEANING Outdoor temperature area Outdoor sensor batteries low oe Indoor sensor batteries Indoor temperature area low main unit batteries low Z Lu REMOTE SENSOR The main unit can collect data from up to 5 sensors To set
3. Weather Home Thermo Bluetooth enabled Thermometer Model EMR211 USER MANUAL lntrod ction eege Eege dee 2 OVETVI W ones cs cice dere eep tedeecteteccensidedstebdecceticcenacvetieds 2 Stein 2 Si 2 Remote Sensor THN 232N 3 Getting E dg ET A Insert batteries est EES 3 Remote EE dideann anniina 3 Sensor data transmission ccccccseeeeeeeeeee tees 4 ul ET iccsciccerctccipaanetectcscecasstiuwecsvaeceenssasidexwtccast 4 eau e eeni EER EEEEE 4 E 4 Connect with your mobile device cccsseeeeees 5 Paring your Thermometer 5 UNS aeeie Ea AEE 6 View current readings ccccccssssseeeeeeeseeeeeeeeeees Z VIEW history PEAGINGS srssissssiesicncdnntecessswtcdeensbevercusnns Optional sensor for additional information POC AUN ONY S access cede eceeavece cose eseeenceece Specifications cocncsnistdscccccsnccecceepccndeccdcanastenasbenteasacene About Oregon Scientific ccceeceeeeeeeeeeeeeeeeeeees EU Declaration of Conformity sceeeeeeeeeees FCC ekateetre neess enge EN or Ola e INTRODUCTION Thank you for selecting our Oregon Scientific Weather Home Bluetooth enabled Thermometer which has changeable display on indoor and outdoor temperature NOTE Please keep this manual handy as you use your new product It contains practical step by step instructions as well as technical specifications and warnings you should know about OVERVIEW SCIE
4. arching displays If you want to cancel the pairing tap Cancel 4 Once the pairing is successful it will return to STATION screen 5 Tap on each channel to rename it Up to 20 characters including space are allowed Tap Done if completed Tap __ to exit To remove sensor To remove any sensor from the weather station Tap Remove station on STATION screen all the sensors will be removed at the same time EN arm STATION EA ca Main a Channel 1 Channel 3 Remove Station To reposition the sensors on screen 1 2 3 SETTINGS On STATION screen tap Press and hold E at the right side of a sensor Drag it to your desired position Tap to confirm You can set your weather station through the application such as measurement units The settings are as follows Temperature Barometric not available in EMR211 Rainfall not available in EMR211 Wind speed not available in EMR211 Altitude not available in EMR211 Show unavailable sensor Automatically sync time Show Sea Level Pressure not available in EMR211 HOME EE 2012 E Cem PARTLY CLOUDY wt Main 1023 hPa To select the measurement unit Tap 3 to view the measurement unit options 2 Tap on your desired unit 3 Tap CG to go back to the previous screen mma SETTINGS _ H STATION ee HOME You can directly view all the You can view history through the application The history wg te
5. ation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help The following information is not to be used as contact for support or sales Please call our customer service number listed on our website at www oregonscientific com or on the warranty card for this product for all inquiries instead 10 We Name Oregon Scientific Inc Address 10778 SW Manhasset Dr UNIT B 2 Tualatin Or 97062 USA 1 800 853 8883 Declare that the product Product No EMR211 Product Name Weather Home Thermo Bluetooth enabled Thermometer Telephone No Manufacturer Address IDT Technology Limited Block C 9 F Kaiser Estate Phase 1 41 Man Yue St Hung Hom Kowloon Hong Kong
6. ect to change without notice NOTE Features and accessories will not be available in all countries For more information please contact your local retailer SPECIFICATIONS MAIN UNIT 93 x 68 x 30 mm LxWxH 3 66 x 2 68 x 1 18 in Weight ee Temperature range for ice alert 3 C to 2 C REMOTE THERMO SENSOR THN132N 96 x 50 x 22 mm SE Sek 3 78 x 1 97 x 0 87 in 62g 2 22 ounces 30 m 98 ft unobstructed Temperature range 20 C to 60 C 4 F to 140 F Power 1 x UM 3 AA 1 5V batteries Weight Transmission range ABOUT OREGON SCIENTIFIC Visit our website www oregonscientific com to learn more about Oregon Scientific products For any enquiry please contact our Customer Services at info oregonscientific com Oregon Scientific Global Distribution Limited reserves the right to interpret and construe any contents terms and provisions in this user manual and to amend it at its sole discretion at any time without prior notice To the extent that there is any inconsistency between the English version and any other language versions the English version shall prevail EU DECLARATION OF CONFORMITY Hereby Oregon Scientific declares that Weather Home Thermo Bluetooth enabled Thermometer model EMR211 is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC A copy of the signed and dated Declaration of Conformity is available on request via our Oregon Sc
7. ientific Customer Service E CNY RS Zo AQ OF COUNTRIES RTTE APPROVAL COMPLIED All EU Countries Switzerland CH and Norway CN FCC STATEMENT This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation EN EN This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separ
8. mperature readings from could also be presented in graphs past 24 hours or HELA different sensors through the past 7 days application at a time The 1023 hPa readings are on the HOME To view the history screen 1 Tap on your desired sensor area on the screen 2 Tap i Ein select your desired data or tap e to sort the data by date e oa PARTLY CLOUDY NOTE If low battery icon fa displays on the screen please replace the batteries for HISTORY SELECT DATE i the corresponding device MON 5 DEC 2012 MON ARES Dan s Home SUN 3DEC TEMPERATURE MAX 34 C 28 5 10 5 SAT 2DEC To show unavailable sensor FRI 1DEC THU 30 NOV If the sensor is out of range the readings are interrupted and dash mode displays on the screen If you do not want to show the unavailable sensor e On SETTINGS screen touch and slide the button to right to turn on the function or sliding to left to turn it off EH OPTIONAL SENSOR FOR ADDITIONAL To automatically synchronize time INFORMATION Time ang date on YAMI EEN station could pe By applying the sensor Model BTH Sensor at the same EES By YOU MODE GEVE time you can also view the following information using e On SETTINGS screen touch and slide the button to your mobile device right to turn on the function or sliding to left to turn it off e Weather Forecast e Air Pressure e Outdoor Humidity WED 29 NOV TUE 28DEC SHOW ALL DATE EN EN US
9. or falls from 37 F to 28 F 3 C to 2 C LED indicator in the front of the main unit will flash continuously and will stop flashing once the temperature is out of this range e Press A and F at the same time to deactivate the ice alert warning e The ice alert warning will be disable enable again when the temperature falls again from 37 F to 28 F 3 C to 2 C NOTE As ice alert is only applicable to channel 1 to prevent flashing of LED select channel 2 5 on outdoor sensor RESET Press RESET at the rear of the main unit to return to the default settings CONNECT WITH YOUR MOBILE DEVICE You can remotely set the thermometer and read the weather information through Bluetooth 4 0 using your mobile device with the downloaded application from the Apple Store To quickly find the application type Weather Home as keyword in the search engine Ensure your mobile device is compatible with iOS 5 or Android 4 3 with Bluetooth v4 0 First of all you need to pair your thermometer with your mobile device will flash on the screen of the weather station while pairing and be on after successful pairing ss EM Pee IN m pu C ap D D j D Bote To pair up a sensor At the rear of the main unit press and hold SET for 2 seconds to enable a pair up for the main unit Le Rename Si STATION a Main N Channel 1 1 Tap to enter SETTINGS screen 2 Tap on STATION area 3 Tap Pair Up Se
10. up the sensor 1 Open the battery compartment 2 Select a channel then press RESET 3 Close the battery door 4 Place the sensor within 98 ft 30 m of the main unit using the table stand or wall mount TIP deal placements for the sensor would be in any location on the exterior of the home at a height of not more than 5 ft 1 5 m and can shield it from direct sunlight or wet conditions for an accurate reading omen Ll EN NOTE Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing To search for a sensor 1 Press A or to select among 5 different outdoor channels of remote sensors 2 Press and hold for 2 seconds to enforce researching for the selected sensor To auto scan among sensors e Press and hold W for 2 seconds to enable auto scan function for all 5 channels The temperatures will be displayed automatically in sequential order Channel 1 2 3 4 5 The sensor reception icon at the front of the main unit shows the status ICON DESCRIPTION 7 OUT oul Main unit is searching for sensor s A channel has been found The sensor cannot be found TIP The transmission range may vary depending on many factors You may need to place the sensor s in different locations to get the best result s TEMPERATURE To select temperature unit e Press SET to select C or F for temperature readings Se ICE ALERT Ifthe channel 1 sens
Download Pdf Manuals
Related Search
Related Contents
Uniden EXS 9650 Cordless Telephone User Manual netIC User Manual and Design Guide Samsung Aire acondicionado tipo ventana 11S-COZY con Turbo Cooling, 5,000 BTU/h Manual de Usuario Contents - Biomiga Copyright © All rights reserved.
Failed to retrieve file