1. Brings only the KVM focus from the port that currently has it to the next port on the installation Scroll Lock Scroll Lock S Enter Brings only the audio focus from the port that currently has it to the next port on the installation Alternate Hotkey Setting Mode The port switching activation keys can be changed from tapping the Scroll Lock key twice Scroll Lock Scroll Lock to tapping the Ctrl key twice Ctrl Ctrl To change the port switch ing activation keys do the following 1 Invoke HSM see page 11 2 Press X Enter Note This procedure is a toggle between the two methods To revert back to the original Scroll Lock Scroll Lock method invoke HSM then press and release the X key again Auto Scanning The GCS1002 GCS1004 s Auto Scan feature automatically cycles the KVM focus through the computer ports at regular intervals This allows you to monitor the computer activity without having to take the trouble of switching from port to port manually Although the video focus switches from port to port the keyboard mouse and USB focus doesn t switch They stay at the port they were on when Auto Scanning started See the table below for details Hotkey Action Scroll Lock Scroll Lock A Enter Invokes Auto Scan The KVM focus cycles from port to port in 5 second intervals A Five second interval is the default setting Scroll Lock Scroll Lock A
2. or booting the computers It also comes equipped with an audio line out and has power on detection it will automatically switch to the next powered on computer when the other is turned off It also allows each computer to access any peripherals connected to the USB 2 0 port And with its audio enabled users can listen to the audio output of each computer on one set of speakers he setup is quick and easy users just need to plug the cables into their appropriate ports here is no software to configure Since the GCS1002 GCS1004 intercepts keyboard input rectly it supports multiple computing platforms PC x86 x64 Macintosh PowerPC and Sun icrosystems Sparc T T lt 2 There are three convenient methods users can use to access the computers port selection pushbuttons located on the unit s front panel hotkey combinations entered from the keyboard and mouse port switching by simply double clicking on the scroll wheel of a USB mouse to change the ports Package Contents 1 x GCS1002 GCS1004 2 4 Port USB DVI KVM Switch 1 x 4ft 44 pin Custom KVM Cable set 1 x 6ft 44 pin Custom KVM Cable set for GCS1004 only 1 x Power Adapter for GCS1004 only 1 x User Manual 1 x Warranty Card e One DVI console controls up to two GCS1002 or four GCS1004 USB interface computers e DVI D KVM cable set includes one 4ft 44 pin custom KVM cable and one 6ft 44 pin custom KVM cable GCS1004 only to connect up to four computers
3. wotg filee OK completion the GCS1002 gt gt Reusing for devices a GCS1004 exits Firmware gt Einnar we vera enter hn device USB DFE KYM MAIN 000 Preparng gede gt gt peste device USB DVI KTM ATID 000 device USB DVL KYM 000 OK Upgrade Mode and resets Y 8021 22 Device FIF Yer 1 0077 Up gwe FIW Ver 10 071 MID 009 I Check Benoa Veram Poges I Eo _Yevtoz Lewa Upgrade Failed If the Upgrade Successful screen doesn t appear it means that the upgrade failed to complete successfully in which case you should do the following 1 Power off the GCS1002 GCS1004 by removing the power jack 2 Invoke Firmware Upgrade Mode by holding down the front panel Port 1 pushbutton see page 19 and power on the GCS1002 GCS1004 For GCS1002 The front panel LEDs flashes For GCS1004 The LEDs for Port 3 and Port 4 will stay on while the LEDs for Port 1 and Port 2 will stay off 8 Follow the firmware upgrade procedure again 20 Specifications Function GCSs1002 GCS1004 Computer Connections 2 4 Console Connections 1 1 Port Selection Hotkey Mouse switch Front panel pushbuttons KB 1 x USB Type A F Iron Console Video 1 x DVI D F White Ports Mouse 1 x USB Type A F Iron Speakers 1 x Mini Stereo Jack F Green KB Connectors oo ane 1 x 44 pin Connector F Speakers KB ee ne A 1 x 44
4. IOGEAIE User Manual 9 4 Port USB DVI KVM Switch GCS1002 GCS1004 PART NO M1265 a www iogear com 2014 IOGEAR All Rights Reserved Part No M1265 a IOGEAR the IOGEAR logo MiniView VSE are trademarks or registered trademarks of IOGEAR Microsoft and Windows are registered trademarks of Microsoft Corporation IBM is a registered trademark of International Business Machines Inc Macintosh G3 G4 and iMac are registered trademarks of Apple Computer Inc IOGEAR makes no warranty of any kind with regards to the information presented in this document All information furnished here is for informational purposes only and is subject to change without notice IOGEAR assumes no responsibility for any inaccuracies or errors that may appear in this document Table of Contents Introduction 4 Package Contents 4 Features 4 Requirements 5 Overview 6 Hardware Installation 8 Basic Operation 10 Hotkey Operation 11 Keyboard Emulation 16 The Firmware Upgrade Utility 18 Specifications 21 Troubleshooting 2D Federal Communications Commission FCC Statement 23 CE Compliance 23 Limited Warranty 23 Contact 23 Introduction This IOGEAR DVI KVM Switch GCS1002 GCS1004 allows users to access up to two GCS1002 or four GCS1004 computers from a single USB keyboard USB mouse and DVI monitor It supports resolutions up to 1920x1200 60Hz With IOGEAR s DynaSyncTM there is no more delay or change of video resolution when switching between
5. s power adapter cable back in 4 After the switch is up power on the computers 10 Hotkey Operation The GCS1002 GCS1004 provide an extensive easy to use hotkey function that makes it convenient to control and configure your KVM installation from the keyboard Hotkey Setting Mode All hotkey operations begin with tapping the Scroll Lock key twice This invokes the Hotkey Setting Mode HSM which can be followed by tapping key combinations and the Enter key o perform various operations The table below describes the actions that each combination performs Note If using the Scroll Lock key conflicts with other programs running on the computer the Ctrl key can be used instead See Alternate Hotkey Setting Mode on page 12 for details Hotkey Action Scroll Lock Scroll Lock Enter Scroll Lock Scroll Lock Port ID Enter Brings the KVM and audio focus from the port that currently has the KVM focus to the next port on the installation 1 to 2 2 to 1 for GCS1002 1 to 2 2 to 3 3 to 4 4 to 1 for GCS1004 For GCS1004 only replace Port ID with the port ID 1 4 to which port you want to switch the KVM and audio focus Note The KVM and audio all go to this port even if they were on different ports to begin with Scroll Lock Scroll Lock X Enter Changes Scroll Lock Scroll Lock to Ctrl Ctrl Press combination again to change back Scroll Lock Scroll Lock K Enter
6. Enter n Starts Auto Scan The KVM focus cycles from port to port at n second intervals Note Replace n with a number between 1 and 4 when entering in this hotkey combination e 1 changes scan interval to 3 seconds e 2 changes scan interval to 5 seconds default e 3 changes scan interval to 10 seconds e 4 changes scan interval to 20 seconds To exit Auto Scan press Esc or Spacebar Auto Scanning stops when you exit Auto Scan Mode When you use the port switching hotkey or HSM the mouse cursor must be in the current computer display While Auto Scan Mode is in effect ordinary keyboard and mouse functions are suspended only Auto Scan Mode compliant keystrokes and mouse clicks can be inputted You must exit Auto Scan Mode press the Esc key or Spacebar in order to regain normal control of the console Video DynaSyncTM Video DynaSync is IOGEAR s exclusive technology that eliminates boot up display problems and optimizes resolution when switching between ports To manually detect and remember monitor EDIDs do the following 1 Invoke HSM see page 11 2 Press D Enter Note If the monitor is disconnected and reconnected the GCS1002 GCS1004 will re exe cute Video DynaSyncTM Mouse Emulation Control The default setting is enabled To disable do the following 1 Invoke HSM see page 11 2 Press M Enter his procedure is a toggle Repeat to enable 4 Mouse Port Switching Th
7. details To cancel press Scroll Lock Scroll Lock F10 Enter Automatically detects and sets the keyboard operating platform F3 Enter F10 Enter List Switch Settings To see a list of the current switch settings do the following 1 Open a text editor or word processor and place the cursor in the page window 2 Invoke HSM see page 11 3 Press F4 Enter to display the settings USB Reset If the USB loses focus and needs to be reset do the following 1 Invoke HSM see page 11 2 Press F5 Enter Keyboard Language To change the keyboard language do the following 1 Invoke HSM see page 11 2 Press F6 nn Enter Note nn is a two digit number that represents the keyboard language code US English 33 French 08 Japanese 15 Restore Default Settings To reset the GCS1002 GCS1004 to its default hotkey setting do the following 1 Invoke HSM see page 11 2 Press R Enter See Hotkey Summary Table on the next page Hotkey Default Settings After invoking HSM see page 11 key in one of the following keys to perform the corresponding function Key Function X Enter Toggles between the default Scroll Lock Scroll Lock and alternate Ctrl Ctrl Port Switching keys K Enter Toggles the KVM focus S Enter Toggles the audio focus A Enter n Starts Auto Scan The KVM focus cycles from port to port at n second
8. e Fully compliant with DVI specification Digital only e Supports multi function and wireless mouse keyboard e Audio enabled full bass response provides a rich experience for 2 1 channel surround sound systems Superior video quality up to 1920 x 1200 60Hz Auto Scan Mode for monitoring all computers Multiplatform support Windows Linux Mac FreeBSD and Sun Console mouse port emulation bypass feature supports most mouse drivers and multifunction mice e Hot Pluggable Add or remove computers for maintenance without powering down the switch e HDCP compliant e Video DynaSync e Power on Detection Automatically switches to the next powered on computer when the other is turned off Computer selection via front panel pushbuttons hotkeys and mouse switching function USB 2 0 mouse port can be used for USB hub and USB peripheral sharing Complete keyboard emulation for error free booting ac Sun keyboard support and emulation Firmware Upgradable Plug amp Play No software installation required Console e 1 DVI display e 1 set of USB keyboard and mouse e Speakers optional Computers e 1 DVI Port e 2 USB Ports e Audio ports optional e Computers with sound support Cables e DVI D KVM cable set 4ft 44 pin cable 6ft 44 pin cable GCS1004 only specifically de signed to work with this switch may be used to link the computers One GCS1002 or two GCS1004 cable set s are provided with this pac
9. e Mac keyboard The emulation mappings are listed in the table below PC Keyboard Mac Keyboard Shift Shift Ctrl Ctr ce ki Ctr 1 Ctr 2 D Ctr 3 z Ci 4 A Alt L Alt Option Print Screen F13 Scroll Lock F14 E Enter Return Backspace Delete Insert Help Ctrl a F15 Note When using key combinations press and release the first key Ctrl then press and release the activation key Sun Keyboard The PC compatible 101 104 key keyboard can emulate the functions of the Sun keyboard when the Control key Ctrl is used in conjunction with other keys The corresponding functions are shown in the table below PC Keyboard Sun Keyboard Cti T Stop Ctrl F2 Again Ctrl F3 Props Ctr F4 Undo Ctr F5 Front Ctri F6 Copy Ctrl F7 Open Ctr F8 Paste Ctri F9 Find Ctri F10 Cut Ctri 1 oO mt Ctri 2 Q mt Ctrl 3 m Ctrl 4 C Ctrl H Help E Compose za Note When using key combinations press and release the first key Ctrl then press and release the activation key The Firmware Upgrade Utility The Windows based Firmware Upgrade Utility FWW Upgrade exe provides a smooth automated process for upgrading the KVM switch s firmware The Utility comes as part of a Firmware Upgrade Package that is specific for each device Check the website regularly to find the latest packages and information relating to them at http www iogear com Be
10. e Mouse Port Switching function can be enabled or disabled The default setting is disabled To enable do the follow 1 Invoke HSM see page 11 2 Press W Enter his procedure is a toggle Repeat to disable 4 ote The feature is only supported when mouse emulation is enabled See Mouse Emulation Control above Power on Detection With the Power On Detection feature the switch automatically switches to the next powered on computer if one computer is powered off This feature is enabled by default to disable 1 Invoke HSM see page 11 2 Press E This procedure is a toggle Repeat to enable Keyboard Operating Platform The GCS1002 GCS1004 s default port configuration is for a PC compatible keyboard operating platform For example if your console uses a PC compatible keyboard and you have a Mac attached to a port you can change the port s keyboard operating platform configuration so that the PC compatible keyboard emulates the Mac keyboard Follow this procedure 1 Bring the KVM focus to the port you want to set 2 Invoke HSM see page 11 8 Press and release the appropriate Function Key see table below After completing this procedure you will automatically exit HSM Function Key Operation F2 Enter Enables Mac keyboard emulation See Mac Keyboard on page 16 for details To cancel press Scroll Lock Scroll Lock F10 Enter Enables Sun keyboard emulation see Sun Keyboard on page 17 for
11. erly connected KVM switch needs to be reset Power off all devices on the installation power off the KVM switch wait five seconds then power up USB devices not responding USB ports need to be reset Unplug the device s USB cable from the USB port on the switch s rear panel then plug it back in Use the USB Reset hotkey combination see Check the cable from the switch to the computer page 14 to reset the USB ports Cannot switch ports by pressing Scroll Lock twice Monitor does not Keyboard is incompatible with Scroll Lock invocation Some graphics Switch to the Alternate HSM invocation keys See Alternate HSM Invocation Keys page 12 for details Power off all devices on the installation power off does not display display after cards are the switch confirm all KVM cables are properly KVM incompatible with connected power on the switch power on the cable set is hot cable set hot computers plugged plugging When switching Monitor is new or Switch ports again and wait two or more sec ports the this is the first time onds for the PC s EDID to pass to the monitor monitor installation The monitor s EDID has not passed through to the PC when switching ports Use the D hotkey to invoke Video DynaSync one more time or switch to another PC to reconnect the switch See Hotkey Summary Table page 15 22 Federal Communications Commi
12. fore you begin 1 From a computer that is not part of your KVM installation go to our Internet support website http www iogear com support dm and search the model name that relates to your device GCS1002 GCS1004 to get a list of available Firmware Upgrade Packages 2 Choose the Firmware Upgrade Package you want to install usually the most recent and download it to your computer 3 Power off the GCS1002 GCS1004 and disconnect it from your KVM installation Connect the 44 pin connector of the custom KVM cable set to the 44 pin Computer Port 1 4 Press and hold the Port 1 pushbutton on the unit s front panel While pressing down on the Port 1 pushbutton connect CPU1 s USB Keyboard Type A connector of the custom KVM cable set to a USB port on your computer Note The Computer Port 1 at the rear panel of the unit is labeled accordingly use the cable that is attached to the CPU1 port 5 Power on the unit and release the Port 1 pushbutton Firmware Upgrade mode is in effect when For GCS1002 The front panel LEDs flashes For GCS1004 The LEDs for Port 3 and Port 4 will stay on while the LEDs for Port 1 and Port 2 will stay off 4 Port USB KVM Switch Gcs1004 Starting the Upgrade 1 Run the downloaded Firmware Upgrade Package file either by double clicking the file icon or using a command line to enter the full path The Firmware Upgrade Utility Welcome screen will appear 2 Read the License A
13. greement click the Agree button Firmware Upgrade Utility Welcome t the Finwuare Upgyade Usin ponr device ints Finmwuare T Mode Ose the Flomeare leer TA Partio your computer or commect vin Ethemef Asyer ta LICENSE GRANT its Firmware ieonas Agwements Thea Click Nest tesa oe FRAK Cit aano e A none car aml we FRM WARE UPGRADE OTILITE dh ERT MA DN Vem way install thy Pt Piirien ike mE ropes ieee retal Print nn afila er Bor wwe on a mabe on offen wonge ade a ead seme ox perenne ets RESTRICTIONS You sgree nol to modiis edaph trudale ceverve engueen mcompia diasembh or otherwise stempi darren sure code ol B Pradu ex carak Seve voks bad onthe Produ or amave aotres or labels on the Product copyright trademark or patent pending notice om anny not sublicense the Product or otherwise allow others 1 me the Prednet licensed 1 yen is X G i gee C Dont Agee te e n 3 Click Next The Firmware Upgrade Utility main screen will appear The Utility will inspect your installation All the devices capable of being upgraded by the package are listed in the Device List panel ck FErmwar Veron s checked compares the dewuce s farmear kvel with the upgrede fin er a a mye Wye oe i ca or xot eit sent checked the wtility pectorms the Click Next begin Device List Status Meseages gt Loading amp teshng files gt Loading amp techn files OK 4 Check Fonvas Yoron Proges Hep _ evlog C
14. he Port LEDs are built into the Port Selection Switches e Flashes indicate that the computer attached to the corresponding port has the KVM focus and is being accessed in Auto Scan Mode see Auto Scanning page 12 e Lights steady to indicate that the computer attached to its corresponding port is the one that has the KVM focus e The LED is off when the port is not selected GCS1004 Back View CPU3 4 CPU 1 2 No Component Description 1 DVI Console Port The cable from your DVI monitor plugs in here Note The USB keyboard and USB mouse ports are located on the unit s side panel The cable s that link the switch to your computers plug in here Note You can identify the computers by the port they are con nected to they are labeled CPU1 CPU2 for GCS1002 CPU1 CPU2 CPU3 CPU4 for GCS1004 2 Computer Port s 3 Power Jack The power adapter cable plugs into this power jack GCS1004 only Hardware Installation Make sure that power to all the devices you will be installing has been turned off You must unplug the power cords of any computers that have the Keyboard Power On function Cable Connections To set up your GCS1002 GCS1004 refer to the installation diagram the numbers in the diagram correspond to the steps below and follow the steps below 1 Plug your speakers into the Audio port located on the unit s side panel optional 2 Plug you
15. intervals Note Replace n with a number between 1 and 4 e 1 changes scan interval to 3 seconds e 2 changes scan interval to 5 seconds default e 3 changes scan interval to 10 seconds e 4 changes scan interval to 20 seconds To exit Auto Scan press Esc or Spacebar D Enter Invokes Video DynaSyncTM IOGEAR s exclusive technology that eliminates boot up display problems and optimizes resolution when switching between ports M Enter Enables disables mouse emulation W Enter Enables disables mouse port switching double click scroll wheel f mouse port switching is active double clicking the scroll wheel of your USB mouse will switch it to the next port E Enables disables Power On Detection F2 Enter Enables Mac keyboard emulation F3 Enter Enables Sun keyboard emulation F10 Enter Automatically detects and sets the keyboard operating platform F4 Enter Lists the current switch settings via the paste function of a text editor F5 Enter Performs a reset on all USB devices F6 nn Enter Sets the keyboard language Note nn is a two digit number that represents one of the following keyboard language code US English 33 French 08 Japanese 15 R Enter Resets the hotkey settings to their default status Keyboard Emulation Mac Keyboard The PC compatible 101 104 key keyboard can emulate the functions of th
16. kage Note The quality of the display is affected by the quality and length of the cables If you need additional cable sets please contact your dealer to purchase the appropriate ones for your switch e DVI cable for your DVI monitor Operating Systems The supporting operating systems are listed in the table below os Version Windows XP 2003 2008 Vista X86 X64 7 8 8 1 Linux RedHat 9 0 and higher SuSE 10 11 1 and higher andriva Mandrake Linux 2006 and higher Debian 3 1 4 0 Ubuntu 7 04 7 10 Unix FreeBSD 5 5 and higher Sun Solaris 8 and higher Novell etware 6 0 and higher Sun Solaris 9 and higher ac OS 9 to 10 5 ote Supports Linux Kernel 2 6 and higher GCS1004 Side View No Component Description 1 Audio Port 2 USB Console Ports The cable from your speakers plugs in here Your USB keyboard and USB mouse plug in here The USB 2 0 mouse port can be used for connecting a USB hub and USB peripheral sharing with mouse emulation off An additional power adapter might be required for the hub GCS1004 Front View 4 Port USB KVM Switch GCS1004 No Component Description 1 Port Selection For manual port selection press a port selection pushbutton to bring Pushbuttons the KVM focus to the computer attached to is corresponding port See Manual Port Switching page 10 for more details 2 Port LEDs T
17. oncel 4 As you select a device from the list its description appears in the Device Description panel After you have made your device selection s click Next to perform the upgrade If you enabled Check xi Firmware Version the Utility Ees fit eget ves s aeva da UN BE yo lee Win et D CERE OE ck TAST compares the device s cae iby rece DA TP ls tec A Click Next to begin firmware level with that of Devies Last Stos Messages the upgrade files If the device s version is higher than the upgrade version a dialog box gives you gt Loeding amp testing file gt eed ing amp ating files OK Ti Ermwar Var 1 0 077 is not nawar then ouent tioram Fer indovxe USB DVI ETM MAIN COD the option to Continue or Si a Cancel oom If you didn t enable Check Dpende F Firmware Version the Utility in aca m stalls the upgrade files without Sa Ee A Ey checking whether they are a ma enor cw higher level or not As the Upgrade proceeds status messages appear in the Status Messages panel and the progress toward completion is shown on the Progress bar Upgrade Successful After the upgrade has completed a screen appears to inform you that the procedure was suc cessful E The Ficrovane upgrade was aoe cesafal Click Finish to close the Firmware Upgrade Utility Click Finish to elase the nblity After a successful pee aes gt Leading amp ating files gt Loading amp
18. pin Connector F Speakers Power A 1 x DC Jack Pushbuttons 2 Green 4 Green Cable Length Aft x 1 44 pin 4ft x 1 6ft x 1 44 pin Power Consumption DC 5 0V 5 0W DC 5 3V 5 3W Emulation KB Mouse USB Video 1920 x 1200 60Hz Scan Interval 3 5 10 20 seconds 5s default Operating Temp 0 50 C Environment Storage Temp 20 60 C Humidity 0 80 RH Non condensing Housing Metal Physical Weight 0 38kg 0 51kg cane Enn 12 30 x 7 54x2 28cem 19 80 x 7 54 x 2 28cm 21 Troubleshooting Operation problems can be due to a variety of causes The first step in solving them is to make sure that all cables are securely attached and seated completely in their sockets In addition updating the product s firmware may solve problems that have been discovered and resolved since the prior version was released If your product is not running the latest firmware version we strongly recommend that you upgrade See the Firmware Upgrade Utility for details Symptom Possible Cause Action Erratic behavior Unit not receiving enough power Use a DC 5 3 V power adapter if you are not already using one If you are already using a power adapter check that it matches the system specifications and that it is plugged in and func tioning properly Keyboard and or mouse need to be reset Unplug the cable s from the console port s then plug it them back in No connection to the computer to make sure it is prop
19. r
20. r USB keyboard and mouse into the USB Console ports located on the unit s side panel Note The USB mouse port can also be used for other USB peripherals that you want share between the computers with mouse emulation off 3 Plug your DVI monitor into the DVI Console port located on the unit s rear panel and power on he monitor 4 Using the provided 44 pin cable set plug the 44 pin connector into the Computer port s of he switch 5 At the other end of the cable plug the USB DVI D and speaker connectors into their respec ive ports on the computer 6 For GCS1004 only plug the power adapter that came with your switch into a power source hen plug the power adapter into the switch s Power Jack 7 Turn on the power to the computers CPU3 4 CPU 1 2 Basic Operation Manual Port Switching There are three convenient methods to access the computers Manual which involves press ing the port selection pushbuttons located on the unit s front panel Mouse which involves clicking the scroll wheel of the mouse and Hotkey which involves entering combinations from the keyboard Hotkey port selection is discussed in the next chapter For manual port selection e Press and release a port selection pushbutton to bring the KVM focus to the computer attached to its corresponding port e Press and release either port selection pushbutton to stop Auto Scan Mode The KVM fo cus goes to the computer attached to the co
21. rresponding port of the switch you pressed Mouse Port Switching The GCS1002 GCS1004 support the very latest in mouse port switching simply double click the scroll wheel of your USB mouse to cycle through the ports Note 1 This feature is only supported by USB 3 key scroll wheel mice 2 The default setting is off 3 It is only supported when Mouse Emulation is enabled See Mouse Emulation Control on page 13 for details Hot Plugging The GCS1002 GCS1004 support USB hot plugging components can be removed and added back into the installation by unplugging their cables from the USB hub ports without the need to shut down the unit Firmware Upgrade Refer to The Firmware Upgrade Utility on page 18 for a step by step guide on upgrading the firmware In summary do the following steps 1 Push and hold the Port 1 pushbutton located on the unit s front panel and power on the unit For GCS1002 The front panel LEDs flashes For GCS1004 The LEDs for Port 3 and Port 4 will stay on while the LEDs for Port 1 and Port 2 will stay off 2 Update the firmware manually via command line by following the instructions shown on the screen Powering off and Restarting If it becomes necessary to Power Off the GCS1002 GCS1004 unit before starting it back up you must do the following 1 Shut down all computers that are attached to the switch 2 Unplug the switch s power adapter cable 3 Wait 10 seconds then plug the switch
22. ssion FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential setting This product generates uses and can radiate radio frequency energy and if not installed and used as directed it may cause harmful interference to radio communications Although this product complies with the limits for a Class B digital device there is no guarantee that interference will not occur in a particular installation CE Compliance This device has been tested and found to comply with the following European Union directives Electromagnetic Capability 2004 108 EC Low Voltage 2006 95 EC and R amp TTED 1999 5 EC Limited Warranty WE RE HERE TO HELP YOU NEED ASSISTANCE SETTING UP THIS PRODUCT Make sure you 1 Visit www iogear com for more product information 2 Visit www iogear com support for live help and product support Warranty Information This product carries a 3 Year Limited Warranty For the terms and conditions of this warranty please go to http Awww iogear com support warranty Register online at http www iogear com register Important Product Information Product Model Serial Number Contact IOGEAR 19641 Da Vinci Foothill Ranch CA92610 www iogear com iogear custhelp com support iogear com 23 QIvGEAR