CyberPower PR1500LCDRTXL2UA uninterruptible power supply (UPS)
Contents
1. LCD STATUS AND SETUP FUCTIONS 1 General Mode a Press the Display button to check the status of the UPS Ff tem it Output Voltage b Press and hold the Display toggle for 4 seconds If the machine is in the Battery Mode it enters the status of Mute If the machine is in the Line Mode it proceeds Self Test c If the Display toggle remains untouched for over 30 seconds the LCD backlight will turn off automatically in 2 Set up Mode 6 Load Capacity Step 1 The machine enters Set Up Mode after holding the Display toggle for 10 seconds Icon S9018 ignis to indicate Set Up Mode 8 certigas e Step 2 By pressing the Display toggle users can switch between setup a enr l functions User configurable functions are as follows a Sensitivity Set the level of tolerance for UPS Increase the UPS compatibility for local utility power condition High The UPS will turn to battery power more often to provide the steady power supply to the connected equipment Low The UPS will tolerate more fluctuations and turn to battery power less often b Battery Pack Numbers This function provides the estimated UPS runtime using various numbers of battery packs The default setting is 0 c Battery Lifetime Show the batteries already used time Reset the logger when battery module replacement or first time installation d Firmware Version Show the UPS version number Sensitivity LS Battery Pack Numbers Step 3 Press a
2. CyberPower FRONT REAR PANEL DESCRIPTION Reliability Quality Value 1 Power Switch Master on off switch for equipment connected to the UPS Smart App Sinewave Series aa ares PR750LCDRTXL2U PR1000LCDRT XL2U Indicates the power is on 3 LCD Module Display PR1 500 LC DRT XL2U a LCD shows all the UPS information with icons and messages 7 4 LCD Display Toggle Button User S Man ual The button can be used to toggle between different data displays K01 0000281 02 on the LCD 5 Battery Backup Protected Outlets IMPORTANT SAFETY WARN I NGS Provides eight battery powered surge protected and AVR outlets for connected equipment and ensures temporary uninterrupted operation of connected equipment during a power failure Critical Non critical When the UPS is overloaded the circuit breakers will be tripped to interrupt the power supply to the uncritical outlets while continuing to supply the critical outlets As well as the battery capacity depletes under the threshold value the uncritical outlets will be shut down and provide energy for critical outlets The threshold can be determined and set by users Non critical outlets can also be turned on off manually through the software package provided 6 Input Power Cord Heavy duty extra long power cord 7 Input Circuit Breaker This manual contains important instructions that should be followed during installation and maintenance of the
3. eBay craigslist or other source to establish that amount Our maximum liability is limited to 400 000 for PR750LCDRTXL2U PR1000LCDRTXL2U PR1500LCDRTXL2Ua Who Pays For Shipping We pay when we send items to you you pay when you send items to us What Are Some Things This Warranty Does Not Cover 1 This Warranty does not cover any software that was damaged or needs to be replaced due to the failure of the Product or any data that is lost as a result of the failure or the restoration of data or records or the reinstallation of software 2 This Warranty does not cover or apply to misuse modification operation or storage outside environmental limits of the Product or the equipment connected to it nor for damage while in transit or in storage nor if there has been improper operation or maintenance or use with items not designed or intended for use with the Product such as laser printers appliances aquariums medical or life support devices etc What Other Limitations Apply 1 This Warranty does not apply unless the Product and the equipment that was connected to it were connected to properly wired and grounded outlets including compliance with electrical and safety codes of the most current electrical code without the use of any adapters or other connectors 2 The Product must have been plugged directly into the power source and the equipment connected to the Product must be directly connected to the Product and not daisy chained
4. 0LCDRTXL2Ua ensures consistent power to your computer system and its included software will automatically save your open files and shutdown your computer system during a utility power loss Replacement of batteries located in an OPERATOR ACCESS AREA CAUTION When replacing batteries replace with the same number of the following battery BP7 2 12FR BB for PR750LCDRTXL2U PR1000LCDRTXL2U PR1500LCDRTXL2Ua CAUTION Risk of energy hazard 12V maximum 7 2 Ampere hour battery BP7 2 12FR Before replacing batteries remove conductive jewelry such as chains wrist watches and rings High energy through conductive materials could cause severe burns CAUTION Risk of battery explosion if battery is replaced by an incorrect type Dispose of used battery according to the instructions AUTOMATIC VOLTAGE REGULATOR AVR CAUTION To reduce the risk of fire connect only to a circuit provided with 20 amperes maximum branch circuit overcurrent protection in The PR750LCDRTXL2U PR1000LCDRTXL2U PR1500LCDRTXL2Ua stabilizes inconsistent utility power The incoming utility power may be accordance with the National Electric Code ANSI NFPA 70 damaging to important data and hardware but with Automatic Voltage Regulation the computer will not experience damaging voltage levels An CAUTION Use only the specified CyberPower replacement battery or battery pack See your dealer for details Automatic Voltage Regulator automatically increases low or decreases high volt
5. THe anot Swiieh is designe Turn the UPS off Wait 10 seconds and then turn the to prevent damage by rapidly turning it off and on MaN The unit is not connected to The unit must be connected to a 110 120V outlet an AC outlet Contact CyberPower Systems about replacement batteries at tech cpsww com Mechanical problem Contact CyberPower Systems at tech cpsww com The serial cable or USB cable Connect the cable to the UPS unit You must use the cable that is not connected came with the unit The cable is connected to the Try another port of your computer wrong port Shutdown your computer and turn the UPS off Wait 10 seconds and turn the UPS back on This should reset the unit The UPS does not perform expected runtime The UPS will not turn on The battery is worn out PowerPanel Personal Edition is inactive The unit is not providing battery power The serial cable is not the cable that was provided with the unit You must use the cable included with the unit for the software Additional troubleshooting information can be found at www cyberpowersystems com support htm TECHNICAL SPECIFICATIONS Model S PR750LCDRTXL2U PR1000LCDRTXL2U PR1500LCDRTXL2Ua Capacity VA 750 1000 1500 Capacity Watts O e a OO k 1350 nput Plug Type nput Voltage Range nput Frequency Range Output On Battery Output Voltage On Battery Output Frequency Transfer Time Typical Lightning Surge Protection 2U Rack 17 1
6. UPS and batteries Please read pa and follow all instructions carefully during installation and operation of the unit Read this manual thoroughly before attempting to unpack install or operate CAUTION The UPS must be connected to a grounded AC power outlet with fuse or circuit breaker protection DO NOT plug the UPS into an outlet that is not grounded If you need to de energize this equipment turn off and unplug the UPS CAUTION DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT CyberPower Systems does not sell products for life support or medical applications DO NOT use in any circumstance that would affect operation or safety of any life support equipment with any medical applications or patient care CAUTION The battery can energize hazardous live parts inside even when the AC input power is disconnected CAUTION For pluggable equipment the socket outlet shall be installed near the equipment and shall be easily accessible CAUTION To prevent the risk of fire or electric shock install in a temperature and humidity controlled indoor area free of conductive contaminants Please see specifications for acceptable temperature and humidity range CAUTION To reduce the risk of electric shock do not remove the cover except to service the battery There are no serviceable parts inside except for the battery Recctisbla lt cheub breakeis orevider Input opimal overioad monitoring and control of your UPS on a network CAUTION To avoid e
7. age to a consistent computer safe 110V 120V The unit powerful CAUTION The battery may present a risk of electrical shock Do not dispose of batteries in a fire as they may explode Follow all local sealed lead acid batteries will provide power only if the incoming voltage drops below 80V or increases above 150V ordinances regarding proper disposal of batteries CAUTION Do not open or mutilate the batteries Released electrolyte is harmful to the skin and eyes and may be toxic SYSTEM BLOCK DIAGRAM CAUTION A battery may present a high risk of short circuit current and electrical shock Take the following precautions before replacing the battery Output 1 Remove all watches rings or other metal objects Filter Suppressor a 2 Only use tools with insulated handles 3 Do not lay tools or metal parts on top of battery or any terminals 4 Wear rubber gloves and boots Input Charger Inverter 5 Determine if the battery is inadvertently grounded If inadvertently grounded remove source of ground CONTACT WITH A GROUNDED AC DC BATTERY CAN RESULT IN ELECTRICAL SHOCK The likelihood of such shock will be reduced if such grounds are removed during installation A and maintenance applicable to a UPS and a remote battery supply not having a grounded circuit Normal Mode gt gt Battery Mode BATTERY REPLACMENT PROCEDURE HARDWARE INSTALLATION GUIDE 1 Your new UPS may be used immediately upon receipt However recharging the b
8. ant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded signal cables must be used with this product to ensure compliance with the Class A FCC limits The Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulation Cet appareil numerique de la class A respecte toutes les exigencies du Reglement sur le materiel brouilleur du Canada
9. arranty Registration Card 4 BATTERY REPLACEMENT S lt p lt a T a 00 10 Serial Port I Serial port allows connection and communication between the UPS and the computer 11 Serial Port Il Serial Port Il relays information to equipment that can utilize a contact closure UPS 12 SNMP HTTP Network slot Remove the cover panel to install optional RMCARD that allows remote e st o D Pupper Butar Contact your dealer or email tech cpsww com Refer to replacement battery pack number RB1270X4F for PR750LCDRTXL2U OVERVIEW IPR1000LCDRTXL2U PR1500LCDRTXL2Ua SS For model PR750LCDRTXL2U PR1000LCDRTXL2U and PR1500LCDRTXL2Ua can support model BP48V45ART2U for external battery pack The PR S0CPDRTACZUFRI GOOLE RRTALAUPRI 500LCDRTXL2Ua provides battery ack p adiomalig Somatic Voltane CN Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery Service the battery under the supervision of personnel vole rogun LAVR ane Optimal Demolnance a1 com pulels and olen helwon equipment DY ensunng increase bet or sooeass NG A j knowledgeable of batteries and their precautions Servicing the battery should only be performed by trained personnel consistent sinewave power The PR750LCDRTXL2U PR1000LCDRTXL2U PR1500LCDRTXL2Ua features 20 volts The AVR automatically provides 2060 Joules of surge protection and provides battery backup during power outages The PR750LCDRTXL2U PR1000LCDRTXL2U PR150
10. attery for at least four hours is recommended to ensure that the battery s maximum charge capacity is achieved Charge loss may occur during shipping and storage To recharge the battery simply leave the unit plugged into an AC outlet The unit D gt will charge in both the on and off position f Bo 2 If you plan to use the included software connect either the serial cable or the USB cable to the corresponding Om port on the UPS and the computer Note if the USB port is used the serial port will be disabled To control 1 Remove two screws and front 2 Remove the four retaining screws of 3 unplug cable connectors multiple computers install PowerPanel Business Edition Agent on the computer connected with the USB cable panel on the right side the cable protection cover then remove and PowerPanel Business Edition Slave on the remaining computers the cover When you first receive the unit plug in the unit to fully charge the battery 3 With the UPS unit off and unplugged connect your computer monitor and any externally powered data storage device Hard drive Tape drive etc into the battery power supplied outlets DO NOT plug a laser printer copier space heater vacuum paper shredder or other large electrical device into the UPS The power demands of these devices will overload and possibly damage the unit 4 Plug the UPS into a 2 pole 3 wire grounded receptacle wall outlet Make sure the wall branch
11. cted Equipment Guarantee together referred to as this Warranty If you do not agree to the terms and conditions of this Warranty you should return the Product for a full refund prior to using it ENERGY SAVING TECHNOLOGY Who is Providing this Warranty CyberPower Systems USA Inc CyberPower provides this Limited Warranty What Does This Warranty Cover This warranty covers defects in materials and workmanship in the Product under normal use and conditions It also covers equipment that was connected to the Product and damaged because of the failure of the Product What is the Period of Coverage This warranty covers the Product for three years and connected equipment for as long as you own the Product Who Is Covered This warranty only covers the original purchaser Coverage ends if you sell or otherwise transfer the Product How Do You Get Service 1 Call us at 877 297 6937 or write to us at Cyber Power Systems USA Inc 4241 12th Ave E STE 400 Shakopee MN 55379 or send us an e mail message at claims cpsww com for instructions 2 When you contact CyberPower identify the Product the Purchase Date and the item s of Connected Equipment Have information on all applicable insurance or other resources of recovery payment that are available to the Initial Customer and Request a Claim Number 3 You must provide a dated Proof of Purchase receipt or other proof of the original purchase and provid
12. e a description of the defect 4 Pack and ship the product with a dated Proof of Purchase receipt to CyberPower and if requested the item s of Connected Equipment a repair cost estimate for the damage to the Connected Equipment and all claim forms that CyberPower provides to you Show the Claim Number on the shipping label or include it with the product You must prepay all shipping costs you are responsible for packaging and shipment and you must pay the cost of the repair estimate How Long Do I Have To Make A Claim All claims must be made within ten days of the occurrence What Will We Do To Correct Problems CyberPower will inspect and examine the Product If the Product is defective in material or workmanship CyberPower will repair or replace it at CyberPower s expense or if CyberPower is unable to or decides not to repair or replace the Product if defective within a reasonable time CyberPower will refund to you the full purchase price you paid for the Product purchase receipt showing price paid is required If it appears that our Product failed to protect any equipment plugged into it we will also send you forms for making your claim for the connected equipment We will repair or replace the equipment that was damaged because of the failure of our Product or pay you the fair market value NOT REPLACEMENT COST of the equipment at of the time of the damage We will use Orion Blue Book or another a third party valuation guide or
13. he OUTPUT voltage readout displays the status of the battery back up outlets Ea A A a ee na o 10 q ESTIMATE RUN TIME This displays the run time estimate of the UPS with the current battery capacity provided in the UPS EPO remote switch which is a Push Back button installed computer room outside by a EPO cable and not connected any other equipment and load NORMAL icon This icon appears when the UPS is working under normal conditions BATTERY icon During a severe brownout or blackout this icon appears and an alarm sounds two short The LCD display indicates a variety of UPS operational beeps followed by a pause to indicate the UPS is operating from its Internal batteries During an extended OPTION 1 USER SUPPLIED NORMALLY CLOSED SWITCH E e conditions All descriptions brownout or blackout that drains the battery a continuous alarm will sound and the BATT CAPACITY A Ser cT a os ala apply when the UPS is plugged readout will show a single shaded segment equaling 20 battery capacity remaining indicating the UPS A a MESON m into the AC outlet and turnedon _ batteries are nearly out of power If this occurs it is recommended that you save your files and manually Ca mm T eA Eeim e or when he UPS ison banen power down your equipment immediately E A AANA A 2 Automatic Voltage Regulation AVR icon This icon appears whenever you
14. lectrical shock turn off the unit and unplug it from the AC power source before servicing the battery or installing a ledan 13 EPO Emergency Power Off Pork computer component 8 USB oie The EPO interface enables connection to an EPO master switch CAUTION DO NOT USE WITH OR NEAR AQUARIUMS To reduce the risk of fire do not use with or near aquariums Condensation from the ie T EE A E 14 Ground Stud aquarium can come in contact with metal electrical contacts and cause the machine to short out Use the Ground Stud to ground the UPS CAUTION For model PR750LCDRTXL2U PR1000LCDRTXL2U and PR1500LCDRTXL2Ua use in a computer room as defined in the ee Sie Wire Taull Indicator 15 External Battery Pack Connector standard for the Protection of Electronic Computer Data Processing Equipment ANSI NFPA 75 als LED mu NAE 1 Wan ie User Mame wing poole Provides a connection for additional CyberPower external battery packs for exists within the AC receptacle such as a bad ground or reversed adended nime wiring If illuminated disconnect all equipment and contact an INSTALLING YOUR UPS SYSTEM electrician to ensure outlet is properly wired UNPACKING Inspect the UPS upon receipt The box should contain the following 1 UPS Unit 1 User s Manual for UPS 2 Rack Mount Brackets 1 Metal Stand Plate 1 Emergency Power Off Cable gray 1 PowerPanel Business Edition Software CD 2 Serial Interface Cable DB 9 1 USB A B Type Cable 1 W
15. nd hold the toggle for 4 seconds When the icons blink the ee value of each item can be changed by slightly pressing the toggle altery Liteume ear 4 Firmware version The settable items are sorted by unit as in the following table Step 4 To save the value and return to general mode press and hold the toggle for 4 seconds Note If the machine is left idle for over 30 seconds during setup it will turn off the backlight and return to general mode automatically Note If user wants to return to general mode without saving changes there are two methods 1 Wait for the backlight to turn off 2 Press and hold the Display toggle for 10 seconds TROUBLE SHOOTIMG O rwm romeca OOOO OOOO Turn the UPS off and unplug at least one piece of equipment Wait 10 seconds reset the circuit breaker by depressing the button and then turn the UPS on f Batteries are discharged Recharge the unit for at least 4 hours Outlet do not provide power g g Unit has been damaged by a Contact CyberPower Systems about replacement batteries at surge or spike tech cpsww com Uncritical outlets have turned off automatically due to an overload Circuit breaker has tripped due to an overload to equipment Push the toggle button to make the uncritical outlets turn on Battery not fully charged Recharge the battery by leaving the UPS plugged in Battery is degraded Contact CyberPower Systems about replacement batteries at tech cpsww com
16. nel Business 4 Pull out the old battery pack and replace new one Reassemble the retaining screws covers black and red cable and front panel in the reverse sequence of the above steps Recharge the unit for 4 8 hours to ensure maximum UPS battery runtime een LOAD CAPACITY utility wall outlet The INPUT voltage readout can be used as a diagnostic tool to identify poor quality input Edition installed connected to Serial Port or the USB port is the computer that you use to control the UPS es A A f ti l power The AVR in this UPS continuously conditions the power to a stable 110 120V output to connected When there is a power failure the primary computer which connects to Serial Port or the USB port will start to BATT CAPACITY f 5 y FJ ma a S equipment In the event of a complete power loss severe brownout or over voltage the UPS relies on its shutdown after a user controlled delay PowerPanel Business Edition Agent software will save and close any ieina balter backup To suppiya consistent 0 120 output 10 EPO Eme ne or Of Por es 0 9 OUTPUT voltage meter This meter measures in real time the AC voltage that the UPS system is LinpuT OUTPUT ESTIMATE RUN_TIME mF ee ae et i ae eah iied ae PETT T a Sg a a providing to the computer such as nomal line mode AVR mode and battery back up mode F i he 7 ai Wi ircu ae u oS ss ee i ies arte 4 ani i j ti eae oe a d v Note T
17. outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical demands e g air conditioner refrigerator copier etc Avoid using extension cords 5 Depress the power switch to turn the unit on The Power On indicator light will illuminate If an overload is detected an audible alarm will sound and the unit will emit one long beep To correct this turn the UPS off and unplug at least one piece of equipment from the battery power supplied outlets Wait 10 seconds Make sure the circuit breaker is depressed and then turn the UPS on 6 Your UPS is equipped with an auto charge feature When the UPS is plugged into an AC outlet the battery will automatically recharge 7 To maintain optimal battery charge leave the UPS plugged into an AC outlet at all times 8 To store your UPS for an extended period cover it and store with the battery fully charged Recharge the Unplug the unit and turn Power battery every three months to ensure battery life Off when first connecting your 9 Professional Rack Mount UPS provide one serial port one dry contact port and one USB port to allow computer and peripherals LCD STATUS DEFINITION communication between the UPS and computers or equipment we dry contact pon Serial me signals INPUT voltage meter This meter measures the AC voltage that the UPS system is receiving from the information for equipment that can utilize a dry contact UPS The primary computer with PowerPa
18. quipment lines or Base 10T Ethernet lines when properly installed and connected This exclusion applies for example to fluctuations in data transmission or reception by CATV or RF transmission or fluctuations or by transients in such transmission 3 Damage from any circumstance described as excluded above with respect to the Product 4 Damages from fire flood wind rain rising water leakage or breakage of plumbing abuse misuse or alteration of either the product or the Connected Equipment 5 CyberPower excludes any liability for personal injury under the Limited Warranty and Connected Equipment Guarantee CyberPower excludes any liability for direct indirect special incidental or consequential damages whether for damage to or loss of property EXCEPT FOR AND ONLY FOR the specific limited agreement of CyberPower to provide certain warranty benefits regarding Connected Equipment under this Warranty loss of profits business interruption or loss of information or data NOTE Some States or Provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you 6 The Product is not for use in high risk activities or with aquariums The Product is not designed or intended for use in hazardous environments requiring fail safe performance or for use in any circumstance in which the failure of the Product could lead directly to death personal injury or severe physical or p
19. r UPS is automatically correcting low AC input line voltage without using battery power This is anormal automatic operation of your UPS and no action is required N O EPO SWITCH SILENT MODE icon This icon appears whenever the UPS is in silent mode The buzzer does not beep during silent mode until the battery reaches low capacity OVER LOAD icon This icon appears and an alarm sounds to indicate the battery supplied outlets are overloaded To clear the overload unplug some of your equipment from the battery supplied outlets until the icon turns off and the alarm stops FAULT icon This icon appears if there is a problem with your UPS RJ11 PLUG NO CONNECTION i _ i ie wie ane we E v T Dry connect is controlled by the PowerPanel Software Install PowerPanel The equipment can BATT CAPACITY meter This meter displays the approximate charge level in 20 increments of the UPS s internal battery During a blackout Please go to www cyberpowersystems com for free download AA aN ahs Business Edition read information or severe brownout the UPS switches to battery back up power the BATT CAPACITY icon appears and the charge level decreases Business Edition a N Ip Ry camac LOAD CAPACITY This meter displays the approximate output load level in 20 increments of the UPS s battery outlets u Note Both USB and Serial can not be used simultaneously the UPS with either a serial cable or a USB cable
20. roperty damage or that would affect operation or safety of any medical or life support device collectively High Risk Activities CyberPower expressly disclaims any express or implied warranty of fitness for High Risk Activities or with aquariums CyberPower does not authorize use of any Product in any High Risk Activities or with Aquariums ANY SUCH USE IS IMPROPER AND IS A MISUSE OF THE PRODUCT What is the Fine Print The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded CyberPower is the warrantor under this Limited Warranty For further information please feel free to contact CyberPower at Cyber Power Systems USA Inc 4241 12th Ave E STE 400 Shakopee MN 55379 call us at 877 297 6937 or send us an e mail message at claims cpsww com Recycle Policy CyberPower Systems encourages environmentally sound methods for disposal and recycling of its UPS products Please dispose and or recycle your UPS and batteries in accordance to the local regulations of your state FCC Notice This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation WARNING This equipment has been tested and found to comply with the limits for a Class A digital device pursu
21. together in serial fashion with any extension cords another Product or device similar to the Product surge suppressor or power tap Any such installation voids the Limited Warranty 3 The Product and equipment connected to it must have been used properly in a suitable and proper environment and in conformance with any license instruction manual or warnings provided with the Product and the equipment connected to it 4 The Product must have been used at all times within the limitations on the Product s VA capacity What are the Limitations The sole and exclusive remedies of the Initial Customer are those provided by this Warranty The Product was designed to eliminate disrupting and damaging effects of momentary less than 1ms voltage spikes or impulses from lightning or other power transients If it can be shown that a voltage spike lasting longer than 1ms has occurred the occurrence will be deemed outside the rated capabilities of the Product and the Limited Warranty is void CyberPower Does Not Cover or Undertake Any Liability in Any Event for Any of the Following 1 Loss of or damage to data records or software or the restoration of data or records or the reinstallation of software 2 Damage from causes other than AC Power Line Transients spikes or surges on properly installed grounded and code compliant 120 volt power lines in the United States and Canada transients surges or spikes on standard telephone land lines PBX telephone e
22. x 15 7 x 3 5 58 NEMA 5 15P Dimensions in Weight Ib Battery Battery Mode Extension Runtime Hot Swappable External Battery ndicators Power On Wiring Fault LCD Display Using Battery AVR Load Level Battery Level Audible Alarms On Battery Low Battery Overload Operating Temperature Operating Relative Humidity Operating Elevation PowerPanel Business Edition CYBERPOWER GREENPOWER UPS TECHNOLOGY GreenPower UPS The CyberPower GreenPower UPS cuts UPS energy costs by up to 75 compared to the conventional UPS circuits Conventional UPS systems pass power through a transformer to provide normal output voltage to protected devices By contrast the GreenPower UPS circuitry bypasses the transformer when utility power is normal significantly increasing the power efficiency of the UPS As a result a GreenPower UPS produces less heat and uses less energy reducing energy costs When utility power is abnormal the GreenPower UPS operates like a normal UPS Since utility power operates normally 88 of the time the GreenPower UPS operates primarily in its cost cutting bypass mode LIMITED WARRANTY AND CONNECTED EQUIPMENT GUARNTEE Read the following terms and conditions carefully before using the CyberPower PR750LCDRTXL2U PR1000LCDRTXL2U PR1500LCDRTXL2Ua the Product By using the Product you consent to be bound by and become a party to the terms and conditions of this Limited Warranty and Conne