Home
Chapin 97300
Contents
1. la bomba con agua despu s de usarla No permita que los productos qu micos reposen en la bomba durante per odos extensos de inactividad Siga las instrucciones del fabricante del producto qu mico respecto al desecho de toda el agua residual del pulverizador BA CHAPIN The Way to Spray Since 1884 011921 R0215 MONTAJE DE LA BOMBA TANQUE Y VALVULA Instrucciones de montaje 1 0 Instale el man metro en el accesorio tal como se ilustra usando un sellador de roscas de buen grado para evitar fugas NO APRIETE DEMASIADO 2 0 Introduzca el conjunto del cable principal en el enchufe en la parte posterior de la bomba 3 0 Una el cable rojo del cable principal a una fuente de 12 voltios en el tractor de jard n El cable negro debe estar conectado a tierra o conectado al borne negativo de la bater a Lista de partes DESCRIPCI N RP00132N Conama de colector sin man metro a rescooasn rar de a bogulla 3 1 RPO00133N Conjunto de la manguera de succi n 6 1 RPO00116N Tanque de 25 galones 94 64 litros Tapa del tanque 8 1 RP00017N Kit del tap n de drenaje 9 3 010987 Engranaje de tomillo sin fin Conjunto de cable principal con enla 96 Varilla sin goteo CHAPIN INTERNATIONAL INC P 0 BOX 549 700 ELLICOTT ST BATAVIA NY 14021 0549 www chapinmfg com 800 950 4458 Manguera de alivio a la parte superior Esta palanca ajusta la presi n del sistema
2. OFF se ajusta con precisi n en la f brica y la presi n de encendido ON se encuentra dentro de un rango permisible por debajo de ese valor Estos ajustes de presi n pueden variar en respuesta a las caracter sticas del sistema en el que se instala la bomba la flexibilidad y la longitud de la tuber a el grifo o las v lvulas y el tiempo durante el cual est n abiertos Por lo tanto se prev la variaci n en el ajuste de presi n con el uso y el paso del tiempo Ajuste del interruptor de presi n En caso de que el ajuste de apagado OOG del interruptor de presi n var e con el uso y el tiempo a un valor inadecuado se puede regular para obtener un rendimiento ptimo Gire el tornillo de ajuste hacia la derecha para aumentar el ajuste de presi n de apagado OFF y hacia la izquierda para disminuirlo El tornillo no se debe ajustar m s de una media vuelta sin consultar a la f brica El ajuste excesivo del interruptor de presi n podr a causar baja presi n en el sistema una conmutaci n entre ciclos r pidos funcionamiento de encendido apagado ON OFF y la reducci n de la vida til de la bomba y del motor Se pueden originar da os La garant a no cubre el ajuste incorrecto del interruptor de presi n Servicio t cnico Anualmente Compruebe el sistema compar ndolo con las normas de funcionamiento Cada 2 a 3 a os Se recomienda reemplazar el diafragma y comprobar su operaci n con las normas de funcionamiento Impo
3. 3 Damaged wiring harness What is the warranty time duration on pump tank and accessories 1 years as stated in operation instructions Pressure gauge reads 85 90 psi before shutting off should pump shut off at 60 psi Pump 7802 2 0 GPM comes preset from the factory to shut off at 60 PSI Should this vary please see Adjusting the Pressure Switch in the operation manual Turn on pump and hold spray wand open slowing adjust until the pump shuts off at 60 PSI Pump continues to run and surge when not spraying Ensure the by pass is completely closed and your system has no leaks Check by pass hose to ensure no fluid is passing through the valve while in the closed position If so replace valve WARNING Ensure the wiring harness does not become pinched or damaged in any way This may damage the pump or cause the wiring harness to overheat resulting in a melt down or fire CHAPIN The Way to Spray Since 1884 CHAPIN INTERNATIONAL INC P 0 BOX 549 700 ELLICOTT ST BATAVIA NY 14021 0549 www chapinmig com 800 950 4458 CHAPIN Assemblage instructions d utilisation pieces f i MOD LE n 97500 25 gallons A AVERTISSEMENT 4h Lire attentivement ces instructions avant l utilisation 95 et 57 litres 25 et 15 gal PULV RISATEUR LOCALIS DE LUXE e R servoir en poly thyl ne 4 6 m 15 pi de boyau e Pompe de 12 volts de 10 mm 3 8 po membrane e Manom tre e 2 g m e Plage de pression
4. d entr e de l eau la pompe n arr tera pas le d bit d eau et ce m me si le moteur est teint S assurer TE le syst me a un moyen positif d interrompre l alimentation eau 4 Ne pas utiliser la pompe dans un environnement caract ris par des risques d explosion Un arc lectrique des balais du moteur une commutation ou une chaleur excessive d un moteur mal cycl peut causer une explosion 5 Ne pas positionner le moteur de la pompe a proximit de mati res plastiques qui fondent a basse temp rature ou d autres mati res combustibles La temp rature de surface du moteur peut d passer 120 C 250 F 6 Ne pas pomper de l essence ou autres fluides inflammables Les materiaux de la t te de la pompe sont concus pour une utilisation avec de l eau seule Ne pas utiliser avec des produits a base de p trole 7 Ne pas assumer la compatibilit des liquides Si les liquides sont incompatibles aux lastom res de la pompe une fuite peut survenir R chauffement 200 Limites de IN 1 temp rature 94 de la surface 0 recommand es a er RES pre ie nt A EA Temp rature F 10 100 110 120 ane ue Valeurs approximatives les valeurs r elles varient selon la temp rature ambiante 8 Pour pr venir les risques de choc lectrique couper l alimentation lectrique avant de commencer tout travail En cas de panne de la pompe le compartiment du moteur et ou le liquide de la pompe peuvent tre conducteurs de
5. et les froides temp ratures Le pulv risateur devrait tre hivern avant l entreposage en pompant une solution d antigel pour VR dans la tuyauterie Des soins et entretiens appropri s prolongeront la vie du pulv risateur AVERTISSEMENT Certains produits chimiques endommageront la pompe et les soupapes s ils demeurent en contact sans traitement pour une p riode prolong e Toujours rincer la pompe avec de l eau apr s utilisation Ne pas laisser de produits chimiques reposer dans la pompe pendant une longue p riode Suivre les directives des fabricants de produits chimiques sur la fa on de disposer de toutes les eaux us es du pulv risateur T N CHAPIN The Way to Spray Since 1884 011921 R0215 Gu a de resoluci n de problemas Problema Causas y soluciones La bomba no arranca La bomba no se apaga l nea de descarga cerrada y no hay fugas Revise Revise j Voltaje 10 y conexiones el ctricas correctas Aire atrapado en la linea de alimentacion o la cabeza de la bomba o Fusible o interruptor de seguridad Voltaje correcto a la bomba o Operaci n del interruptor de presi n y voltaje correcto f Residuos en las v lvulas de alimentacion descarga de la bomba en el interruptor Conjunto de transmision o tornillos de la cabeza de la bomba flojos o Rectificador o motor para circuito abierto o con Operaciones ajustes al interruptor de presi n conexi n a tierra Conjunto de la transmisi
6. l extr mit de l adaptateur automobile S assurer de la bonne tension 10 12 13 volts Le flux est faible ou absent Que dois je v rifier V rifier la pr sence d un boyau d aspiration bouch et ou de la cr pine d aspiration Souvent vous aurez besoin de nettoyer la cr pine d aspiration V rifier la bonne tension Y a t il un fusible pour le pulv risateur Oui un fusible de ligne un fusible situ dans le compartiment de l adaptateur de l automobile ou les deux Quelle taille de fusible devrais je utiliser en remplacement 7 5 A Quelle est la port e du tube de pulv risation 10 7 m 35 pi max Comment devrais je nettoyer le r servoir apr s utilisation 1 Bien rincer le r servoir avec de l eau seulement vider et remplir d eau 2 Ouvrir le robinet d arr t et laisser l eau couler par l assemblage de d charge Vider le pulv risateur 3 Ranger le r servoir du pulv risateur l envers avec la pompe retir e dans un endroit chaud et sec Y a t il une vis de r glage sur la pompe pour r gler la pression Oui consulter les instructions de fonctionnement R gler le commutateur de pression Comment retirer remplacer un fusible Devisser le connecteur du fusible de ligne ou le compartiment de l adaptateur automobile Est ce que la buse de pulv risation du tube peut tre remplac e par une buse diff rente Oui Cependant votre tube de pulv risation vient avec la buse standard no 18 Les buses en lait
7. liberando l quido nuevamente al tanque El ajuste de esta palanca aumentar o disminuir la presi n a la varilla pulverizadora y al brazo pulverizador Esta palanca enciende y apaga el brazo pulverizador Hacia el brazo pulverizador si est equipado Para solicitar partes de repuesto 1 800 950 4458 CHAPIN The Way to Spray Since 1884 Serie 7800 PowerFLO Bombas de diafragma impulsada por motor de 12 voltios de CC Modelo 7802 2 0 Gal min 7 57 litros min Especificaciones Motor Tipo 12 VCC im n permanente totalmente cerrado no ventilado Cables 16 AwG de 12 30 48 cm de largo Ciclo de servicio Consulte el gr fico de aumento de calor L mites de temperatura El motor no est equipado con protecci n t rmica Para la seguridad del usuario un rendimiento ptimo y la m xima vida til del motor la temperatura de la superficie del motor no debe exceder los 150 F 66 C consulte el gr fico de aumento de calor arriba a la derecha Bomba Tipo 3 Bomba de diafragma de 3 c maras con desplazamiento positivo autocebada capaz de funcionar en seco modelo por demanda o de derivaci n Certificaciones Norma 59 del NSF Temperatura del l quido 140 F 60 C m x Capacidades de cebado 14 pies 4 m Presi n m xima 60 PSI Puertos de alimentaci n descarga 7802 De r pida instalaci n Materiales de construcci n Carcasa Polipropileno Diafragma Santoprene V lvul
8. n bloqueado Fugas en la cabeza o interruptor de la bomba Revise La bomba no adquiere cebado no hay descarga con el motor operando Tornillos sueltos en el interruptor o cabeza de la bomba Revise Diafragma del interruptor roto O pellizcado Residuos en el colador Diafragma perforado si hay liquido presente Restricciones torceduras en los tubos de alimentaci n descarga o Residuos o crecimientos en las v lvulas de alimentaci n descarga Preguntas frecuentes sobre la pulverizaci n y la bomba Por qu la bomba no funciona todo el tiempo Esta es una bomba de demanda y nicamente funciona con caudal varilla pulverizadora derivaci n puntas de pulverizaci n o fugas en el sistema Por qu la bomba se revoluciona al usar la varilla pulverizadora Un caudal bajo puede causar que la bomba se revolucione o conmute ciclos Esto podr a pasar cuando la varilla pulverizadora est ajustada para un patr n de pulverizaci n ligero o fino Para arreglarlo abra ligeramente la v lvula de derivaci n C mo regulo la presi n La presi n debe ajustarse mediante la regulaci n de la v lvula de derivaci n apertura o cierre ligeros Cu l es la presi n de funcionamiento ptima 40 PSI Esto se puede lograr mediante la activaci n de la bomba y el ajuste de la v lvula de derivaci n hasta que el man metro arroje una lectura de 40 PSI o ligeramente superior La bomba funcionar de manera continua Aseg rese de que la plu
9. 00 Ces pulv risateurs sont con us pour tre fix s une surface stable UTILISATION Le syst me de pompe aspire la solution du r servoir travers la cr pine et dans la pompe La pompe force la solution sous pression dans le tuyau de pulv risation La pompe a un interrupteur de pression qui arr tera la pompe si elle atteint 60 psi La pression peut tre r gularis e en ouvrant ou en fermant la soupape de derivation sur le dessus du reservoir Plus elle est ouverte plus basse est la pression Inspecter r guli rement le tamis d alimentation de l aspiration a l int rieur du r servoir Rincer avec de l eau pour d gager tout d bris accumul APRES LA PULVERISATION Apres utilisation remplir le pulv risateur en partie avec de l eau D marrer le pulv risateur et laisser l eau claire tre pomp e dans le syst me de tuyauterie et hors du tuyau de pulv risation Remplir le r servoir moiti avec de l eau seule et utiliser un neutralisant chimique et r p ter les instructions de nettoyage Rincer le pulv risateur en entier avec l agent neutralisant Suivre les directives de disposition du fabricant quant aux eaux de lavage ou de rin age ENTREPOSAGE HIVERNAL Entierement drainer l eau et les produits chimiques hors du pulv risateur portant une attention sp ciale a la pompe et les soupapes Ces articles sont sp cialement enclins a tre endommag s par les produits chimiques
10. F al 10 100 110 120 aa aia Approximate values actual values will vary with ambient temperature Pressure Sensing Demand Switch The PowerFLO Series 7800 pump is controlled by a built in pressure sensing demand switch When a faucet or valve is opened down stream of the pump line pressure drops thus starting the pump automatically Conversely when the valve shuts the line pressure increases turning the pump off automatically The pressure switch actuates in response to the pump outlet pressure at a predetermined and preset pressure The pump label indicates the predetermined ON and OFF pressures Typically the OFF pressure is accurately set at the Factory and the ON pressure is within an allowable range below that value In response to the characteristics of the system in which the pump is installed the flexibility and length of the tubing the faucet or valves and the duration that they are open these pressure settings may vary Therefore variation in pressure setting is expected with use and over time Adjusting the Pressure Switch Should the pressure switch OFF setting vary with use and time to an unsuitable value it may be adjusted for optimum performance Turn the setscrew clockwise to increase the OFF pressure setting and counter clockwise to decrease The screw should not be adjusted more than one half turn without consulting the Factory Excessive adjustment of the pressure switch could cause low system pressure ra
11. Guide de depannage Problemes causes et solutions La pompe ne d marre pas La pompe ne s arr tera pas la ligne de sortie est ferm e et ne fuit pas V rifier V rifier La tension 10 et les connexions lectriques L air emprisonn e dans la ligne de sortie ou dans la o Le fusible ou disjoncteur t te de la pompe o Le fonctionnement de l interrupteur de pression et la i La tension de la pompe tension l interrupteur Les d bris dans les soupapes d entr e sortie de la pompe o Le redresseur ou le moteur pour tout circuit ouvert ou Desserrer l assemblage d entrainement ou les vis de la mis la terre t te de pompe L assemblage d entra nement verrouill Les op rations r glages de l interrupteur de pression La pompe ne s amorcera pas ne pas d charger pendant que le Fuites de la t te de pompe ou de l interrupteur moteur tourne Verifier V rifier Desserrer les vis de l interrupteur ou de la t te de pompe Les d bris dans la cr pine o La membrane d interrupteur est rompue ou pincee o Les restrictions plis dans les tubes d arriv e sortie La membrane perc e si du fluide est pr sent Les d bris ou une augmentation dans les soupapes d arriv e sortie FAQ Pulverisateur et pompe Pourquoi la pompe ne fonctionne t elle pas en tout temps Il s agit d une pompe la demande qui ne fonctionne qu avec un flux tube de pulv risation d rivation buses de pulv risation ou fuite dans
12. PIN INTERNATIONAL INC P 0 BOX 549 700 ELLICOTT ST BATAVIA NY 14021 0549 www chapinmfg com 800 950 4458 CHAPIN Assembly Operation Instructions Parts Ea MODEL 97500 25 Gallon WARNING Carefully Read These Instructions Before Use 25 amp 15 GAL DELUXE SPOT SPRAYER Polyethylene Tank e 15 Ft of 3 8 Hose 12 Volt Diaphragm Pump Pressure Gauge 2 0 G P M e Adjustable Pressure Range Lever Handgun 0 60 PSI Max GENERAL INFORMATION The purpose of this manual is to assist you in assembling operating and maintaining your lawn and garden sprayer Please read it carefully as it furnishes information which will help you achieve years of dependable trouble free operation WARRANTY PARTS SERVICE Products are warranted for one year from date of purchase against manufacturer or workmanship defects Your authorized dealer is the best source of replacement parts and service To obtain prompt efficient service always remember to give the following information 1 Correct part description and part number 2 Model number of your sprayer Part description and part numbers can be obtained from the illustrated parts list section of this manual Whenever you need parts or repair service contact your dis tributor dealer first For warranty work always take your original sales slip or other evidence of purchase date to your distributor dealer ASSEMBLY INSTRUCTIONS Tools r
13. ajustable e Levier de la lance 0 60 psi max INFORMATION G N RALE Ce manuel est destin vous aider assembler utiliser et entretenir votre pelouse et pulv risateur Veuillez le lire attentivement car il vous fournira l information qui vous aidera obtenir des ann es d utilisation fiable et sans probl mes GARANTIE PI CES SERVICE Les produits sont garantis pour un an partir de la date d achat contre les d fectuosit s de fabrication et de main d uvre Votre d taillant autoris est la meilleure source de pi ces de remplacement et de service Pour obtenir un service rapide et efficace toujours se souvenir de fournir l information suivante 1 La bonne description et le bon num ro de pi ce 2 Le num ro de mod le de votre pulv risateur La description des pi ces et les num ros de pi ces peuvent tre obtenus de la section de la liste illustr e des pi ces de ce manuel Que vous ayez besoin de pi ces ou d un service de r paration communiquez avec votre distributeur d taillant en premier Pour des travaux sous garantie toujours amener le re u de vente original ou autre preuve de la date d achat chez le distributeur d taillant INSTRUCTIONS D ASSEMBLAGE Outils requis 1 Cl plate 9 16 po 1 Produit d tanch it des filetages CHAPIN INTERNATIONAL INC P 0 BOX 549 700 ELLICOTT ST BATAVIA NY 14021 0549 www chapinmig com 800 950 4458 0 6 Ez Bl 1
14. apertura o el cierre de la v lvula de derivaci n situada en la parte superior del tanque Cuanto m s se abre menor ser la presi n Inspeccione regularmente el filtro de suministro de succi n en el interior del tanque Enjuague con agua para eliminar cualquier residuo acumulado DESPUES DE PULVERIZAR Despu s de usarlo llene la parte del pulverizador con agua Arranque el pulverizador y permita que bombee agua limpia a trav s del sistema de tuber as y que salga por la vara pulverizadora Rellene el tanque hasta la mitad con agua limpia y use un neutralizador qu mico y repita las instrucciones de limpieza Enjuague el pulverizador completo con el agente neutralizador Siga las instrucciones de desecho del fabricante de la sustancia qu mica para toda el agua de lavado y enjuagado ALMACENAMIENTO EN INVIERNO Drene toda el agua y los quimicos del pulverizador prestando especial atencion a la bomba y las valvulas Estos articulos son especialmente susceptibles a danos generados por los productos quimicos y el agua congelada El pulverizador debe protegerse contra el frio antes de almacenarlo bombeando una soluci n de anticongelante RV a trav s de todas las tuber as El cuidado y mantenimiento apropiados prolongaran la vida del pulverizador ADVERTENCIA Algunos productos qu micos da ar n las v lvulas de la bomba si se les permite remojarse sin tratamiento durante un per odo extenso de tiempo Siempre enjuague
15. as Viton Elementos de sujeci n Acero inoxidable Peso 6 Ib 2 7 kg Precauciones de instalaci n y operaci n 1 La bomba est equipada con un interruptor de la demanda de detecci n de presi n que controla la presi n m xima operativa 2 Adem s nunca exponga la bomba a presiones por encima de 125 PSI 8 5 bar 3 Mientras existe presi n de agua de entrada la bomba no detendr el flujo de agua hacia adelante incluso si el motor est apagado Aseg rese de que el sistema disponga de medios eficaces para cerrar el suministro de agua 4 No haga funcionar la bomba en un entorno explosivo La formaci n de arcos en las escobillas del motor interruptor o el calor excesivo de un motor con un ciclo incorrectamente completado pueden provocar una explosi n No coloque el motor de la bomba cerca de los pl sticos de baja temperatura o material combustible La temperatura de la superficie del motor puede exceder 250 F 120 C 6 No bombee gasolina ni otros liquidos inflamables Los materiales del cabezal de la bomba est n dise ados para su uso nicamente con agua No utilice con productos derivados del petr leo No asuma la compatibilidad de los l quidos Si el l quido no esta bien adaptado a los elast meros de las bombas se puede producir una fuga 8 Para evitar una descarga el ctrica desconecte la energ a antes de iniciar cualquier trabajo En el caso de fallo de la bomba el l quido de la carcasa del motor o de
16. blemas GARANTIA PARTES SERVICIO Los productos estan garantizados por un ano a partir de la fecha de compra contra defectos de manufactura o mano de obra Su distribuidor autorizado es la mejor fuente de partes de repuesto y servicio Para obtener servicio r pido y eficiente siempre recuerde proporcionar la siguiente informaci n 1 Descripci n y n mero de parte correctos 2 N mero de modelo de su pulverizador La descripci n y n mero de las partes pueden consultarse en la secci n de lista de partes ilustradas de este manual Siempre que necesite partes o servicio de reparaci n contacte primero a su distribuidor Para trabajos bajo garant a siempre lleve su nota de compra original u otra evidencia de la fecha de compra a su distribuidor INSTRUCCIONES DE ARMADO Herramientas necesarias 1 Llave de tubo de 9 16 1 Sellador para roscas CHAPIN INTERNATIONAL INC P 0 BOX 549 700 ELLICOTT ST BATAVIA NY 14021 0549 www chapinmfg com 800 950 4458 MODELO N 97300 15 galones 56 78 litros Estos pulverizadores est n dise ados para sujetarse a una superficie estable OPERACI N El sistema de bombeo obtiene la soluci n desde el tanque a trav s del filtro y hacia la bomba La bomba impulsa la soluci n bajo presi n hacia la vara pulverizadora La bomba tiene un interruptor de presi n que apagar la bomba cuando alcance las 60 PSI La presi n se puede regular mediante la
17. een 20 and 40 PSI My pump quit and will not restart what should I check Check all electrical connections Ensure switch is in the on position Check in line fuse and or fuse in car adapter end Ensure correct voltage 10 12 13 volt Low flow or no flow at all what should I check Check for a clogged suction hose and or suction strainer Often you will need to clean the suction strainer Check for proper voltage Is there a fuse for the sprayer Yes either an in line fuse a fuse located in the car adapter housing or both What size fuse should I use as a replacement 7 5 amp What is the range of the spray wand 35 feet max How should I clean the tank after use 1 Rinse tank thoroughly with water only empty refill with water 2 Open shut off and allow water to run through discharge assembly Empty sprayer 3 Store sprayer tank upside down in a warm dry location Is there an adjustment screw on the pump to adjust pressure Yes please refer to the operation instructions Adjusting the Pressure Switch How do I remove replace fuse Unscrew in line fuse connector or unscrew the car adapter housing Can the spray tip on the wand be replaced with a different type of tip Yes however your wand comes with a 18 tip which is standard Brass tips generally produce better spray patterns than plastic Each time I turn on the pump my fuse blows 1 Excessive voltage 2 Improper adjustment of the pressure switch
18. equired 1 9 16 End Wrench 1 Thread Sealant MODEL 97300 15 Gallon These sprayers are designed to he attached to a stable surface OPERATION The pumping system draws solution from the tank through the strainer and to the pump The pump forces the solution under pressure to the spray wand The pump has a pressure switch which will shut the pump off when it reaches 60 PSI Pressure may be regulated by opening or closing the bypass valve located on the top of the tank The more it is opened the lower the pressure will be Regularly inspect the suction supply screen on the inside of the tank Flush with water to clear any accumulated debris AFTER SPRAYING After use fill the sprayer part way with water Start the sprayer and allow clear water to be pumped through the plumbing system and out through the spray wand Refill the tank about half full with plain water and use a chemical neutralizer and repeat cleaning instructions Flush the entire sprayer with the neutralizing agent Follow the chemical manufacturer s disposal instructions of all wash or rinsing water WINTER STORAGE Drain all water and chemical out of sprayer paying special attention to pump and valves These items are especially prone to damage from chemicals and freezing weather The sprayer should be winterized before storage by pumping a solution of RV antifreeze through the entire plumbing Proper care and mai
19. es de mauvais fonctionnement etc Puisque les pompes peuvent contenir des r sidus de produits chimiques ces tapes sont n cessaires afin de prot ger les gens responsable du retour de la marchandise et pour aider discerner les causes exactes de la d faillance CHAPIN INTERNATIONAL INC P 0 BOX 549 700 ELLICOTT ST BATAVIA NY 14021 0549 www chapinmfg com 800 950 4458 an ASSEMBLAGE DE LA POMPE DU RESERVOIR ET DE LA SOUPAPE Instructions d assemblage 1 0 Installer la soupape dans le raccord comme illustr avec un produit d tanch it des filetages de haute qualit afin de pr venir les fuites NE PAS TROP SERRER 2 0 Ins rer le fil conducteur dans la fiche se trouvant l arri re de la pompe 3 0 Joindre le fil rouge du fil conducteur un connecteur 12 V sur le tracteur de jardin Le fil noir doit tre mis la terre ou connect la borne n gative de la batterie RPO0099N Trousse de buse 6 1 RPOOTIEN R servoir de 95 litres 25 gal 8 1 RPO0017N Trousse bouchon de drainage Oga J3 010987 Vis sans fin Ensemble de fil principal avec interrupteur 2 4 is 96 po Pompe 2 2 gpm CHAPIN INTERNATIONAL INC P O BOX 549 700 ELLICOTT ST BATAVIA NY 14021 0549 www chapinmig com 800 950 4458 Vers la baguette de pulv risation Tuyau de d compression vers le haut du reservoir Ce levier r gle la pression du syst me en r acheminant le liquide vers le reser
20. haute tension de composantes normalement consid r es s curitaires Par cons quent toujours tenir compte du risque de choc lectrique lors de travaux ou de manipulation d quipement lectrique En cas de doute consulter un lectricien Tous les travaux relatifs aux fils lectriques devraient tre effectu s par un lectricien qualifi conform ment au code de l lectricit national et local Contacteur manom trique La pompe PowerFLO de s rie 7800 est contr l e par un contacteur manom trique int gr Lorsqu un robinet ou une soupape est ouvert en aval de la pompe il y a chute de pression du conduit et la pompe d marre automatiquement Inversement lorsque la soupape se referme la pression du conduit augmente fermant la pompe automatiquement Linterrupteur de pression est actionn pour r pondre a la pression de la sortie de la pompe et ce a une pression pred termin e et prereglee L tiquette sur la pompe indique les pressions pr d termin es qui allument et teignent la pompe Habituellement la pression OFF est r gl e avec exactitude en usine et la pression ON tombe dans une plage admissible sous cette valeur En r ponse aux caract ristiques du syst me dans lequel est install e la pompe la flexibilit et la longueur de la tuyauterie du robinet ou des soupapes et la dur e pendant laquelle ils sont ouverts ces param tres de pression peuvent varier Par consequent on s attend une variation du para
21. la bomba puede llevar alta tensi n a los componentes que normalmente se consideran seguros Por lo tanto siempre tenga en cuenta el peligro de descarga el ctrica cuando trabaja y manipula equipos el ctricos Si no est seguro consulte a un electricista nicamente un electricista calificado por los c digos el ctricos locales y estatales debe realizar el cableado el ctrico UT N CHAPIN INTERNATIONAL INC P 0 BOX 549 700 ELLICOTT ST BATAVIA NY 14021 0549 www chapinmfg com 800 950 4458 Aumento de calor 200 H me de 180 temperatura recomendado EE FA PRE Eee TA E A Temperatura F 0 10 20 30 40 50 60 70 80 90 100 110 120 Tiempo minutos Valores aproximados los valores reales pueden variar con la temperatura ambiente Interruptor de la demanda de detecci n de presi n Un interruptor de la demanda de detecci n de presi n integrado controla la bomba de la serie 7800 PowerFlo Cuando se abre un grifo o una v lvula aguas abajo de la bomba la presi n de la l nea cae poniendo as en marcha la bomba de forma autom tica En caso contrario cuando la v lvula se cierra la presi n de la l nea aumenta apagando la bomba autom ticamente El interruptor de presi n act a en respuesta a la presi n de salida de la bomba a una presi n predeterminada y preestablecida La etiqueta de la bomba indica las presiones de encendido ON y apagado OFF predeterminadas Normalmente la presi n de apagado
22. le syst me Pourquoi la pompe a t elle des pouss es pendant l utilisation du tube de pulv risation Un faible flux peut causer des pouss es de la pompe ou fluctuation Ceci peut survenir lorsque le tube de pulv risation est r gl pour un mod le de pulv risation petit ou fin Pour en venir bout ouvrir l g rement la soupape de d rivation Comment r gler la pression La pression doit tre r gl e l aide de la soupape de d rivation ouverture ou fermeture l g re Quelle est la pression de fonctionnement optimale 40 psi cela peut tre accompli en mettant la pompe en fonction et en r glant la soupape de d rivation jusqu ce que la jauge affiche 40 psi ou l g rement sup rieur La pompe fonctionnera en continu S assurer que l peron ou le levier ne pulv risent pas pendant le r glage de la pression La pression diminuera l g rement apr s que l peron ou le levier sont utilis s Quelle pression doit tre affich e au manom tre Consulter les instructions de fonctionnement pour les pressions de fonctionnement de l peron des pressions de l peron vari es peuvent tre atteintes en r glant la soupape de d rivation Habituellement la baguette de pulv risation fonctionne entre 20 et 40 psi Ma pompe s arr te et ne red marre pas Que dois je v rifier V rifier toutes les connexions lectriques S assurer que l interrupteur est en position de marche ON V rifier le fusible de ligne et ou le fusible de
23. ll not Prime No discharge with motor running Leaks from Pump Head or Switch Check Check Debris in strainer Loose screws at switch or pump head Restriction kinks in inlet outlet tubes Switch diaphragm ruptured or pinched Debris or swelling in inlet outlet valves Punctured diaphragm if fluid is present Spray amp Pump FAQs Why does the pump not run all the time This is a demand pump and only runs with flow spray wand by pass spray tips or leak in system Why does the pump surge while using the spray wand Low flow may cause the pump to surge or cycle This could happen when the spray wand is adjusted for a small or fine spray pattern To overcome slightly open the by pass valve How do I adjust the pressure Pressure should be adjusted by regulating the by pass valve slightly opening or closing What is the optimal operating pressure 40 PSI This can be accomplished by turning on the pump and adjusting the bypass valve until the gauge reads 40 PSI or slightly higher The pump will run continuously Ensure that the boom and or handgun is not spraying while you set the pressure The pressure will drop slightly when the boom and or handgun is operated What pressure should the pressure gauge read Please refer to the operation instructions for boom operating pressures varying boom pressures can be achieved by regulating or adjusting the by pass valve Typically the spray wand will be operated betw
24. m SEA CHAPIN Serie PowerFLO 7800 Pompe de 12 volts a membrane actionn e par moteur Modele 7802 2 0 gpm Normes techniques Moteur Type 12 V c c aimant permanent totalement ferme non ventil Connecteurs 16 AWG longueur de 12 po Cycle de service Voir le graphique de r chauffement Limites de temp rature Le moteur n est pas dot de protection thermique Pour garantir la s curit de l utilisateur des performances optimales et une dur e maximale de la vie du moteur la temp rature de la surface du moteur ne doit pas d passer 150 F 66 C voir le graphique de r chauffement ci dessus droite Pompe Type pompe membrane de 3 chambres volum triques auto amor ant capacit fonctionner sec mod le de demande ou d rivation Certifications norme NSF 58 Temp rature de liquide 60 C 140 F max Capacit s d amorcage 4 m 14 pi Pression max 60 psi Ports d entr e sortie 7802 Attache rapide Materiaux de construction Compartiment polypropylene Membrane Santoprene Soupapes Viton Attaches Acier inoxydable Poids 6 lb 2 7 kg Precautions li es l installation et au fonctionnement 1 La pompe est munie d un contacteur manom trique qui contr le la pression de fonctionnement maximale 2 De plus ne jamais soumettre la pompe des pressions plus lev es que 125 psi 8 5 bars 3 Tant qu il y a une pression
25. m tre de pression avec l usage et le temps R gler le commutateur de pression Si le commutateur de pression teint OFF varie et qu il existe un param tre de temps inad quat cela peut tre r gl pour un rendement optimum Tourner la vis de r glage dans le sens des aiguilles d une montre pour augmenter le r glage de pression OFF et dans le sens contraire des aiguilles d une montre pour diminuer ce r glage La vis ne doit pas tre ajust e plus d un demi tour sans consulter le manufacturier Un r glage excessif du commutateur de pression pourrait causer une pression faible du syst me des cycles rapides ON OFF et une vie r duite du moteur et de la pompe Des dommages peuvent se produire La garantie ne couvre pas un r glage inappropri de l interrupteur de pression Main d uvre Tous les ans v rifier les normes de fonctionnement du syst me Tous les 2 3 ans Nous recommandons le remplacement de la membrane et la v rification des normes de fonctionnement Instructions importantes de retour s curitaire Lors d un retour de votre pompe pour une r paration ou au titre de la garantie toujours suivre les tapes suivantes 1 Rincer les r sidus chimiques de la pompe plus facile si effectu dans le champ 2 Etiqueter la pompe avec le type de produits chimiques ayant t pulverises 3 Inclure la description compl te du probl me de fonctionnement notamment l utilisation de la pompe les sympt m
26. ma o la pistola de mano no est realizando la pulverizaci n mientras establece la presi n La presi n caer ligeramente cuando se opera la pluma o la pistola de mano Qu presi n debe leer el man metro Consulte las instrucciones de operaci n para informarse sobre las presiones de trabajo de la pluma se pueden lograr diferentes presiones de la pluma mediante la regulaci n o el ajuste de la v lvula de derivaci n Normalmente la varilla pulverizadora se operar entre 20 y 40 PSI Mi bomba se apaga y no reinicia qu debo revisar Revise todas las conexiones el ctricas Aseg rese de que el interruptor est en la posici n de encendido Revise el fusible de la l nea de alimentaci n o el fusible en el extremo del adaptador para coche Aseg rese de que el voltaje sea el correcto 10 12 a 13 voltios Caudal bajo o nada de caudal qu debo revisar Compruebe que la manguera de succi n o el filtro de succi n no est n obstruidos A menudo necesitar limpiar el filtro de succi n Verifique el voltaje apropiado Hay un fusible para el pulverizador S puede ser un fusible en la l nea de alimentaci n uno colocado en la carcasa del adaptador para coche o ambos Qu tama o de fusible debo usar como repuesto 7 5 A Cu l es el rango de la varilla pulverizadora 35 pies 10 66 m m ximo C mo debo limpiar el tanque despu s de usarlo 1 Enjuague minuciosamente el tanque nicamente con agua vacie y vuel
27. ntenance will prolong the life of the sprayer WARNING Some chemicals will damage the pump valves if allowed to soak untreated for a long period of time Always flush the pump with water after use Do not allow chemicals to sit in pump for extended times of idleness Follow chemical manufacturers instructions on disposal of all waste water from the sprayer CHAPIN INTERNATIONAL INC P 0 BOX 549 700 ELLICOTT ST BATAVIA NY 14021 0549 www chapinmfg com 800 950 4458 ae 011921 R0215 PUMP TANK amp VALVE ASSEMBLY Assembly Instructions 1 0 Install gauge in fitting as illustrated using a good grade thread sealant to prevent leaks DO NOT OVER TIGHTEN 2 0 Insert lead wire assembly into plug at rear of pump 3 0 Join red wire of the lead wire to a 12V source on the garden tractor The black wire should be grounded or connected to the negative battery post Oo Parts List _ _ _ _ _ _ _ _ Y e 1 RPO01 TEN 25 Galon Tank e 1 RPo0017N Kit Drain Pug o s 070987 worm Gear This lever turns the Spray To Spray Boom if equipt Relief Hose to top of tank This lever adjusts the system pressure by relieving liquid back to the tank Adjusting this level will increase or decrease pressure to the Spray Wand or the Spray Boom To Order Replacement Parts 1 800 950 4458 CHAPIN INTERNATIONAL INC P O BOX 549 700 ELLICOTT ST BATAVIA NY 14021 0549 www chapinmfg com 800 950 4458 res umm
28. on produiront g n ralement de meilleurs mod les de pulv risation que le plastique Chaque fois que je mets la pompe en marche mes fusibles sautent 1 Tension excessive 2 R glage inappropri de l interrupteur de pression 3 Filage endommag Quelle est la garantie longueur de temps de la pompe le r servoir et les accessoires 1 ans comme il est inscrit dans les instructions d utilisation Le manometre affiche 85 90 psi avant de s teindre la pompe devrait elle s teindre 60 psi La pompe 7802 2 0 GPM est programm e en usine pour s teindre 60 psi Si cela varie veuillez consulter R gler le commutateur de pression dans le manuel d utilisation Mettre la pompe en fonction et tenir la baguette de pulv risation en position ouverte r gler doucement jusqu ce que la pompe s teigne 60 psi La pompe continue de fonctionner et s intensifie lorsqu on ne pulv rise pas S assurer que la d rivation est compl tement ferm e et que votre syst me ne comporte aucune fuite V rifier le tuyau de d rivation pour assurer qu aucun liquide ne passe au travers la soupape lorsqu en position ferm e Si c est le cas remplacer la soupape AVERTISSEMENT Assurez vous que le filage ne se coince pas ou ne soit pas endommag d aucune fa on que ce soit La pompe pourrait en tre endommag e ou causer une surchauffe au filage provoquant une d faillance ou un incendie rN CHAPIN The Way to Spray Since 1884 CHA
29. pid cycling ON OFF Operation and reduced pump and motor life Damage may occur The Warranty does not cover improper adjustment of the pressure switch Servicing Every Year Check system against operating standards Every 2 3 Years We recommend replacing the diaphragm and checking against operating standards Important return safety instructions UE you return your pump for warranty or repair you must always do the ollowing 1 Flush chemical residue from the pump best done in the field 2 Tag pump with type of chemicals having been sprayed 3 Include complete description of operation problem such as how pump was used symptoms of malfunction etc Since pumps can contain residues of toxic chemicals these steps are necessary to protect all the people who handle return shipments and to help pinpoint the reason for the breakdown CHAPIN The Way to Spray Since 1884 Troubleshooting Guide Problem Causes and Remedies Pump will not Start Pump will not Shut Off Output line closed and no leaks Check Check Correct voltage 10 and electrical connections Air trapped in outlet line or pump head Fuse or breaker Correct voltage to pump o Pressure switch operation and correct voltage at switch Debris in pump inlet outlet valves Rectifier or motor for open or grounded circuit Loose drive assembly or pump head screws Locked drive assembly Pressure switch operations adjustments Pump wi
30. rtantes instrucciones de seguridad para el retorno de la bomba Cuando retorne la bomba para servicios dentro de la garant a o su reparaci n siempre se debe hacer lo siguiente 1 Enjuague los residuos qu micos de la bomba mejor hacerlo en el campo 2 Etiquete la bomba con el tipo de productos qu micos que se han pulverizado 3 Incluya una descripci n completa del problema de operaci n por ejemplo c mo se utiliz la bomba los s ntomas de mal funcionamiento etc Dado que las bombas pueden contener residuos de productos qu micos t xicos estos pasos son necesarios para proteger a todas las personas que se ocupan de los env os de retorno y para ayudar a identificar la causa de la aver a CHAPIN The Way to Spray Since 1884
31. ue la bomba se apague a los 60 PSI La bomba contin a funcionando y se sobretensiona cuando no est pulverizando Aseg rese de que la derivaci n est completamente cerrada y que el sistema no tiene fugas Compruebe la manguera de derivaci n para asegurar que no haya l quido pasando a trav s de la v lvula mientras est en la posici n cerrada Si es as reemplace la v lvula ADVERTENCIA Aseg rese de que el cable no se pellizque o da e de ninguna manera Esto podr a da ar la bomba o hacer que el cable se sobrecaliente dando lugar a piezas derretidas o un incendio MA CHAPIN INTERNATIONAL INC P 0 BOX 549 700 ELLICOTT ST BATAVIA NY 14021 0549 www chapinmfg com 800 950 4458 ial CHAPIN Conjunto Instrucciones de operacion Partes MODELO N 97500 25 galones 94 64 litros ADVERTENCIA Lea estas instrucciones atentamente antes de utilizarlo PULVERIZADOR DE LUJO 25 GALONES 94 64 litros y 15 GALONES 56 78 litros e Tanque de polietileno e 15 pies 4 5 m de e Bomba de diafragma manguera de 3 8 de 12 voltios e Man metro e 2 0 Gal min 7 57 litros minuto e Rango de presi n e Pistola de palanca regulable 0 60 PSI m x INFORMACION GENERAL El objetivo de este manual es ayudarle a armar operar y dar mantenimiento a su pulverizador de patio y jardin Por favor l alo cuidadosamente ya que contiene informacion que le ayudara a obtener a os de operaci n confiable y sin pro
32. va a llenar con agua 2 Abra la unidad de cierre y deje fluir el agua a trav s del conjunto de descarga Vacie el pulverizador 3 Guarde el tanque del pulverizador en posici n invertida en un lugar seco y templado Hay un tornillo de ajuste en la bomba para ajustar la presi n Si consulte las instrucciones de operaci n Ajuste del interruptor de presi n C mo quito reemplazo el fusible Desenrosque el conector del fusible en la l nea de alimentaci n o la carcasa del adaptador para coche Puede cambiarse la punta de pulverizaci n en la varilla por una punta de diferente tipo Si pero si varilla viene con una punta N 18 que es la est ndar Las puntas de lat n generalmente producen mejores patrones de pulverizaci n que las de pl stico Cada vez que enciendo la bomba se quema el fusible 1 Voltaje excesivo 2 Ajuste incorrecto del interruptor de presi n 3 Arn s de cableado da ado Cu l es la garant a tiempo de duraci n de la bomba tanque y accesorios 1 a os tal como se establece en las instrucciones de operaci n Manometro lee 85 a 90 psi antes de apagarse la bomba deber a apagarse a 60 psi La bomba 7802 de 2 0 gal min 7 57 litros minuto viene preestablecida de f brica para apagarse a 60 PSI Si esto var a consulte la secci n Ajuste del interruptor de presi n en el manual de operaci n Encienda la bomba y sostenga la varilla pulverizadora abierta ralentizando el ajuste hasta q
33. ver subject the pump to pressures above 125 PSI 8 5 bars 3 As long as there is inlet water pressure the pump will not stop forward flow of water even if the motor is turned off Be sure the system has positive means of shutting off water supply 4 Do not operate pump in an explosive environment Arcing from the motor brushes switch or excessive heat from an improperly cycled motor may cause an explosion 5 Do not locate the pump motor near low temperature plastics or combustible material The surface temperature of the motor may exceed 250 F 120 C 6 Do not pump gasoline or other flammable liquids Pump head materials are designed for use with water only Do not use with petroleum products 7 Do not assume fluid compatibility If the fluid is improperly matched to the pumps elastomers a leak may occur 8 To prevent electrical shock disconnect power before initiating any work In the case of pump failure the motor housing and or pump fluid may carry high voltage to components normally considered Safe Therefore always consider electrical shock hazard when working with and handling electrical equipment If uncertain consult an electrician Electrical wiring should only be done by a qualified electrician per local and state electrical codes CHAPIN INTERNATIONAL INC P 0 BOX 549 700 ELLICOTT ST BATAVIA NY 14021 0549 www chapinmig com 800 950 4458 Heat Rise Recommended A Shell Temperature Limit Temperature
34. voir L ajustement de ce levier augmentera ou diminuera la pression dans le tuyau de pulv risation ou dans la rampe de pulv risation Ce levier permet d activer et de desactiver la rampe de pulverisation Vers la rampe de pulv risation le cas ch ant Pour commander des pieces de remplacement 1 800 950 4458 EA r CHAPIN The Way to Spray Since 1884 PowerFLO 7800 Series 12 Volt DC Motor Driven Diaphragm Pumps Model 7802 2 0 GPM Specifications Motor Type 12 VDC permanent magnet totally enclosed non ventilated Leads 16 AWG 12 long Duty Cycle See Heat Rise graph Temperature Limits Motor is not equipped with thermal protection For user safety optimal performance and maximum motor life the motor surface temperature should not exceed 150 F 66 C see Heat Rise graph above right Pump Type 3 chamber positive displacement diaphragm pump self priming capable of being run dry demand or bypass model Certifications NSF Standard 58 Liquid Temperature 140 F 60 C Max Priming Capabilities 14 feet 4 m Max Pressure 60 PSI Inlet Outlet Ports 7802 Quick Attach Materials of Construction Housing Polypropylene Diaphragm Santoprene Valves Viton Fasteners Stainless steel Weight 6 Ibs 2 7 kg Installation and Operation Precautions The pump is equipped with a pressure sensing demand switch that controls the maximum operating pressure 2 In addition ne