1. 4 RS 232 Terminal Block connector Connects to the controlled unit 5 LINE IN RJ 45 connector Connects to the LINE OUT RJ 45 connector on the TP 123 or the TP 104 6 XGA OUT 15 pin HD F connector Connect to the XGA acceptor 7 LINK LED Iluminates when receiving the correct input signal 8 LEVEL trimmer Adjusts the output signal level 9 EQ trimmer Adjusts the cable compensation equalization level 10 ON LED llluminates when receiving power 7 2 1 Your TP 124 XGA Audio Data Line Receiver Underside Figure 12 and Table 11 define the underside of the TP 124 XGA Audio Data Line Receiver POLARITY Figure 12 TP 124 XGA Audio Data Line Receiver Underside Table 11 TP 124 XGA Audio Data Line Receiver Underside Features Feature Function 1 VS Switch Slide the switch up to set the V SYNC to positive polarity slide the switch down to set the V SYNC to negative polarity 2 HS Switch Slide the switch up to set the H SYNC to positive polarity slide the switch down to set the H SYNC to negative polarity 1 Using a UTP cable with CAT 5 connectors at both ends the PINOUT is defined in Table 12 and Figure 14 2 The TP 104 does not accept the audio signals 3 Degradation and VGA XGA signal loss can result from using long cables due to stray capacitance sometimes leading to a total loss of sharpness
2. Figure 1 TP 104 XGA Line Transmitter DA Figure 2 TP 104HD XGA Line Transmitter DA Figure 3 TP 104 Underside Panel Figure 4 TP 105 CAT 5 Line Driver DA Figure 5 TP 121 XGA Audio Line Transmitter Figure 6 TP 121 Internal Polarity Switches Figure 7 TP 122 XGA Audio Line Receiver Topside Figure 8 TP 122 XGA Audio Line Receiver Underside Figure 9 TP 123 XGA Audio Data Line Transmitter SOD UNAUNSP LN Nm mm i mm i a e i NO ON DAN BWW NOOO WO N N n w 27 Contents Figure 10 TP 123 Internal Polarity Switches Figure 11 TP 124 XGA Audio Data Line Receiver Topside Figure 12 TP 124 XGA Audio Data Line Receiver Underside Figure 13 Connecting the XGA Audio Line Transmitter Receiver System Figure 14 CAT 5 PINOUT Figure 15 Connecting the XGA Audio Data Line Transmitter Receiver System Figure 16 RS 232 PINOUT Connection Figure 17 Configuring a 1 4 XGA to Twisted Pair Transmitter Receiver DA Figure 18 Configuring a TP 105 CAT 5 Line Driver DA Tables Table 1 Table 2 Table 3 Table 4 Table 5 Table 6 Table 7 Table 8 Table 9 TP 104 TP 104HD XGA Line Transmitter DA Features TP 104 Underside Panel Features TP 105 CAT 5 Line Driver DA Features TP 121 XGA Audio Line Transmitter Features Features of the TP 121 Internal Polarity Switches TP 122 XGA Audio Line Receiver Topside Features TP 122 XGA Audio Line Receiver Underside Features TP 123 XGA Audio Data Line Transmitter Features
3. Features of the TP 123 Internal Polarity Switches Table 10 TP 124 XGA Audio Data Line Receiver Topside Features Table 11 TP 124 XGA Audio Data Line Receiver Underside Features Table 12 CAT 5 PINOUT Table 13 RS 232 PINOUT Connection Table 14 Technical Specifications of the TP 104 and the TP 104HD Table 15 Technical Specifications of the TP 105 and the TP 105 HD Table 16 Technical Specifications of the TP 121 TP 122 TP 123 TP 124 14 15 16 18 19 21 22 24 il KRAMER SIMPLE CREATIVE TECHNOLOGY Introduction Introduction Welcome to Kramer Electronics Since 1981 Kramer Electronics has been providing a world of unique creative and affordable solutions to the vast range of problems that confront the video audio presentation and broadcasting professional on a daily basis In recent years we have redesigned and upgraded most of our line making the best even better Our 1 000 plus different models now appear in 11 groups that are clearly defined by function Thank you for purchasing your Kramer TOOLS TP 104 TP 104HD XGA Line Transmitter DA and or TP 105 TP 105 HD CAT 5 Line Driver DA and or TP 121 XGA Audio Line Transmitter and or TP 122 XGA Audio Line Receiver and or TP 123 XGA Audio Data Line Transmitter and or TP 124 XGA Audio Data Line Receiver which are ideal for e Presentation and multimedia applications e Long range graphics distribution for schools hospitals security and stores
4. The package includes one or more of the following Kramer TOOLS e TP 104 TP 104HD TP 105 TP 105 HD TP 121 TP 122 TP 123 or TP 124 e Power adapter 12V DC e This user manual Getting Started We recommend that you e Unpack the equipment carefully and save the original box and packaging materials for possible future shipment e Review the contents of this user manual e Use Kramer high performance high resolution cables 1 GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Matrix Switchers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialty AV Products GROUP 7 Scan Converters and Scalers GROUP 8 Cables and Connectors GROUP 9 Room Connectivity GROUP 10 Accessories and Rack Adapters GROUP 11 Sierra Products 2 Download up to date Kramer user manuals at http www kramerelectronics com 3 The complete list of Kramer cables is on our Web site at http www kramerelectronics com Getting Started 2 1 Quick Start This quick start chart summarizes the basic setup and operation steps z Quick Start TP 121 TP122 Step 1 Connect the Machines TP123 TP 124 Computer Graphics TP 121 Connect the video and audio inputs TP 122 Connect the video and audlo outputs Connect the TP 121 to the TP 122 via the CATS cable Display Computer Graphics Audio RS 232 Control wh Stereo Audio Recorder TP 123 Connect the v
5. e TP 121 XGA Audio Line Transmitter and the TP 122 XGA Audio Line Receiver see section 6 e TP 123 XGA Audio Data Line Transmitter and the TP 124 XGA Audio Data Line Receiver see section 7 This section describes e Using shielded twisted pair STP unshielded twisted pair UTP see section 3 1 e The power connect feature see section 3 2 e Recommendations for achieving the best performance see section 33 Shielded Twisted Pair STP Unshielded Twisted Pair UTP We recommend that you use Shielded Twisted Pair STP cable There are different levels of STP cable available and we advise you to use the best quality STP cable that you can afford Our non skew free cable Kramer BC STP is intended for analog signals where skewing is not an issue For cases where there is skewing our UTP skew free cable Kramer BC XTP may be used Bear in mind though that we advise using STP cables where possible since the compliance to electromagnetic interference was tested using those cables Although Unshielded Twisted Pair UTP cable might be preferred for long range applications the UTP cable should be installed far away from electric cables motors and so on which are prone to create electrical interference However since the use of UTP cable might cause inconformity to electromagnetic standards Kramer does not commit to meeting the standard with UTP cable 1 Video only KRAMER SIMPLE CREATIVE TECHNOLOGY Overview 3
6. 15 pin HD F connector on the first TP 120 unit to the XGA acceptor for example Display 1 XGA OUT 15 pin HD F connector on the second TP 120 unit to the XGA acceptor for example Display 2 On each of the four Kramer units connect the 12V DC power adapter to the power socket and connect the adapter to the mains electricity The signal from the XGA source is transmitted via the two CAT 5 cables decoded and converted at the each of the XGA OUT 15 pin HD F connectors to the XGA acceptors If necessary Adjust the video output signal level and or cable compensation equalization level on the TP 105 and on both the TP 120 units Set the H SYNC and V SYNC switches on the underside of the TP 120 units 1 Refer to the separate user manual PT 110 WP 110 TP 120 which can be downloaded from the Internet at http www kramerelectronics com 2 Via UTP cabling with a range of more than 300ft gt 100m For details of how to wire a CAT 5 LINE IN LINE OUT RJ 45 connector see section 8 1 3 Use a screwdriver to carefully rotate the trimmer adjusting the appropriate level 4 By default both switches are set down for negative V SYNC and H SYNC polarity 25 Configuring a TP 105 CAT 5 Line Driver DA Computer Graphics Source Long CATS line Display Display Figure 18 Configuring a TP 105 CAT 5 Line Driver DA 26 KRAMER SIMPLE CREATIVE TECHNOLOGY Technical Specifications 12 T
7. 2 About the Power Connect Feature The Power Connect feature applies as long as the cable can carry power This feature is available when using STP cable and the distance does not exceed 50m on standard CAT 5 cable For longer distances heavy gauge cable should be used For units which are connected via RJ 45 connectors make sure that the shield of the STP cable is connected to the metal casing of the connectors on both ends of the cable For units which are connected via terminal block connectors the shield of the STP cable must be connected to a ground terminal on the units at both ends use the ground terminal of the power supply connection if necessary For a CAT 5 cable exceeding a distance of 50m separate power supplies should be connected to the transmitter and to the receiver simultaneously 3 3 Recommendations for Achieving the Best Performance To achieve the best performance e Use only good quality connection cables to avoid interference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables e Avoid interference from neighboring electrical appliances that may adversely influence signal quality and position your Kramer product away from moisture excessive sunlight and dust No operator serviceable parts inside unit Use only the Kramer Electronics input power wall adapter that is provided with the unit WEILL Disconnect power and unplug unit from wall
8. before installing or removing the device or servicing unit 1 CAT 5 cable is still suitable for the video audio transmission but not for feeding the power at these distances 2 Available from Kramer Electronics on our Web site at http www kramerelectronics com 5 Your TP 104 TP 104HD XGA Line Transmitter DA 4 Your TP 104 TP 104HD XGA Line Transmitter DA The TP 104 TP 104HD is a line transmitter 1 4 DA that receives an XGA signal and transmits it over four CAT 5 cables to appropriate receivers In particular the TP 104 TP 104HD e Has a transmission range of more than 300ft more than 100m e Can power or be powered by the receiver over the same CAT 5 cable and is 12V DC fed Figure defines the TP 104 and Figure 2 defines the TP 104HD KRAMER TOOLS XGA Line Transmitter DA KRAMER TOOLS XGA Line Transmitter DA TP 104HD Figure 2 TP 104HD XGA Line Transmitter DA 1 The TP 104HD is similar to the TP 104 but can also receive HD signals high definition resolutions 480p 576p 720p 1080i and 1080p 2 The terminology XGA is used throughout this manual where this implies any RGBHV signal on a 15 pin HD F connector having a resolution from VGA up to XGA 6 KRAMER SIMPLE CREATIVE TECHNOLOGY Your TP 104 TP 104HD XGA Line Transmitter DA Table 1 TP 104 TP 104HD XGA Line Transmitter DA Features Feature Function 1 12V DC 12V DC connector for po
9. output signal level 8 EQ trimmer Adjusts the cable compensation equalization level 9 ON LED llluminates when receiving power 1 Using a UTP CAT 5 cable with RJ 45 connectors at both ends the PINOUT is defined in Table 12 and Figure 14 2 The TP 104 does not accept the audio signals 3 Degradation and VGA XGA signal loss can result from using long cables due to stray capacitance sometimes leading to a total loss of sharpness in high resolution signals 4 Use a screwdriver to carefully rotate the trimmer adjusting the appropriate level 11 Your TP 121 TP 122 6 2 2 Your TP 122 XGA Audio Line Receiver Underside Figure 8 and Table 7 define the underside of the TP 122 X GA Audio Line Receiver Figure 8 TP 122 XGA Audio Line Receiver Underside Table 7 TP 122 XGA Audio Line Receiver Underside Features Feature Function 1 VS Switch Slide the switch up to set the V SYNC to positive polarity slide the switch down to set the V SYNC to negative polarity 2 HS Switch Slide the switch up to set the H SYNC to positive polarity slide the switch down to set the H SYNC to negative polarity 1 The underside is identical on the TP 122 and TP 124 2 By default both switches are set down for a negative V SYNC and H SYNC polarity 12 KRAMER SIMPLE CREATIVE TECHNOLOGY Your TP 123 TP 124 7 1 XGA Audio Data Line Transmitter TP 123 Your TP 123 TP
10. to pin cable with RJ 45 connectors Table 12 CAT 5 PINOUT Figure 14 CAT 5 PINOUT EIA TIA 568A EIA TIA 568B PIN Wire Color PIN Wire Color 1 Green White 1 Orange White 2 Green 2 Orange 3 Orange White 3 Green White 4 Blue 4 Blue 5 Blue White 5 Blue White 6 Orange 6 Green 7 Brown White 7 Brown White 8 Brown 8 Brown E T Pair 1 4and5 Pair1 4and5 Pair 2 3 and 6 Pair2 1and2 Pair 3 1 and 2 Pair3 3 and6 Par4 7and8 Pair4 7and8 TAAS R SS Connecting the XGA Audio Data Line Transmitter Receiver You can use the TP 123 XGA Audio Data Line Transmitter and the TP 124 XGA Audio Data Line Receiver to configure a twisted pair transmitter and receiver system to transmit the video audio and RS 232 control signals via CAT 5 UTP cable To connect the TP 123 and the TP 124 to configure a twisted pair transmitter and receiver system as the example in Figure 15 illustrates do the following 1 On the TP 123 connect An XGA source for example a laptop s graphics card to the XGA IN 15 pin HD F connector and an audio source to the Audio IN 3 5mm mini jack for example using a Kramer C GMA GMA cable VGA 15 pin HD M Audio jack to VGA 15 pin HD M Audio jack An RS 232 cable with a 9 pin D sub connector at one end to the laptop and a 2 PIN terminal block connector at the other end to 1 Not supplied The full list of Kramer cables is on our Web site at h
11. 124 This section describes the TP 123 XGA Audio Data Line Transmitter see section 7 1 and the TP 124 XGA Audio Data Line Receiver see section 7 2 Your TP 123 XGA Audio Data Line Transmitter The TP 123 is a high performance transmitter that accepts a computer graphics input signal an unbalanced stereo analog audio signal unidirectional RxD RS 232 control commands and 12V DC power over CAT 5 cable and transmits to a TP 124 receiver The stereo analog audio signal is converted to the digital audio S PDIF stream before transmitting thus preserving the quality of the audio source signals The TP 123 TP 124 pair has a transmission range of more than 300ft more than 100m over UTP cabling In addition the TP 123 e Can power or be powered by the TP 124 receiver over the same CAT 5 cable and is 12V DC fed Figure 9 and Table 8 define the TP 123 00O N Ss KRAMER TOOLS RS 232 Aupio IN 12v Dc ON Figure 9 TP 123 XGA Audio Data Line Transmitter Your TP 123 TP 124 Table 8 TP 123 XGA Audio Data Line Transmitter Features Feature Function 1 12V DC 12V DC connector for powering the unit 2 AUDIO IN 3 5mm mini jack Connects to the audio source 3 RS 232 terminal block connector Connects to the PC or the Remote Controller see section 9 1 4 LINE OUT RJ 45 connector Connects to the LINE IN RJ 45 connector on the TP 124 XGA Audio Line
12. 3 12V DC 190mA TP 122 12V DC 200mA TP 124 12V DC 540mA TP 121 TP 122 pair 12V DC 550mA TP 123 TP 124 pair when powered from TP 121 via Power when powered from TP 123 via Power Connect Connect 12V DC 390mA TP 121 TP 122 pair 12V DC 390mA TP 123 TP 124 pair when powered from TP 122 via Power when powered from TP 124 via Power Connect Connect DIMENSIONS 12 1cm x 7 18cm x 2 42cm 4 76 x 2 83 x 0 95 W D H WEIGHT 0 3kg 0 67lbs approx ACCESSORIES Power supply OPTIONS 19 rack mount 1 For the Transmitter Receiver pair 28 KRAMER SIMPLE CREATIVE TECHNOLOGY LIMITED WARRANTY Kramer Electronics hereafter Kramer warrants this product free from defects in material and workmanship under the following terms HOW LONGIS THE WARRANTY Labor and parts are warranted for seven years from the date of the first customer purchase WHOIS PROTECTED Only the first purchase customer may enforce this warranty WHAT IS COVERED AND WHAT IS NOT COVERED Except as below this warranty covers all defects in material or workmanship in this product The following are not covered by the warranty 1 Any product which is not distributed by Kramer or which is not purchased from an authorized Kramer dealer If you are uncertain as to whether a dealer is authorized please contact Kramer at one of the agents listed in the Web site www kramerelectronics com 2 Any product on which the serial number has been defaced modi
13. Kramer Electronics Ltd USER MANUAL Models TP 104 TP 104HD XGA Line Transmitter DA TP 105 TP 105 HD CAT 5 Line Driver DA TP 121 XGA Audio Line Transmitter TP 122 XGA Audio Line Receiver TP 123 XGA Audio Data Line Transmitter TP 124 XGA Audio Data Line Receiver Contents Contents 1 Introduction 2 Getting Started 2 1 Quick Start 3 Overview 3 1 Shielded Twisted Pair STP Unshielded Twisted Pair UTP 3 2 About the Power Connect Feature 3 3 Recommendations for Achieving the Best Performance 4 Your TP 104 TP 104HD XGA Line Transmitter DA 5 Your TP 105 TP 105 HD CAT 5 Line Driver DA 6 Your TP 121 TP 122 6 1 Your TP 121 XGA Audio Line Transmitter 6 1 1 The TP 121 Internal Polarity Switches 6 2 Your TP 122 XGA Audio Line Receiver 6 2 1 Your TP 122 XGA Audio Line Receiver Topside 6 2 2 Your TP 122 XGA Audio Line Receiver Underside 7 Your TP 123 TP 124 7 1 Your TP 123 XGA Audio Data Line Transmitter 7 1 1 The TP 123 Internal Polarity Switches hd Your TP 124 XGA Audio Data Line Receiver 7 2 1 Your TP 124 XGA Audio Data Line Receiver Underside 8 Connecting the XGA Audio Line Transmitter Receiver 8 1 Wiring the CAT 5 LINE IN LINE OUT RJ 45 Connectors 9 Connecting the XGA Audio Data Line Transmitter Receiver 9 1 Controlling via RS 232 for example using a PC 10 Configuring a 1 4 XGA to TP Transmitter Receiver DA 11 Configuring a TP 105 CAT 5 Line Driver DA 12 Technical Specifications Figures
14. Receiver 5 XGA IN 15 pin HD F connector Connect to the XGA source 6 ON LED Iluminates when receiving power 7 1 1 The TP 123 Internal Polarity Switches Figure 10 and Table 9 define the internal sync polarity switches inside the TP 123 Note that you need to open the TP 123 unit to gain access to the Vs and Hs Polarity switches After setting the switches close the TP 123 unit POLARITY XGA Audio Data Line Transmitter TP 123 Figure 10 TP 123 Internal Polarity Switches Table 9 Features of the TP 123 Internal Polarity Switches Feature Function VS Switch Slide the switch down to set the V SYNC to negative polarity NEG slide the switch up to set the V SYNC to its input polarity NORM HS Switch Slide the switch down to set the H SYNC to negative polarity NEG slide the switch up to set the H SYNC to its input polarity NORM 1 Using a UTP CAT 5 cable with RJ 45 connectors at both ends the PINOUT is defined in Table 12 and Figure 14 2 By default both switches are set down for a negative V SYNC and H SYNC polarity 14 KRAMER SIMPLE CREATIVE TECHNOLOGY Your TP 123 TP 124 7 2 Your TP 124 XGA Audio Data Line Receiver The TP 124 is a high performance receiver obtaining the computer graphics signal audio control data from the Kramer TP 123 via UTP cabling at its CAT 5 Line input The TP 124 outputs a computer graphics signal an unbalanced stereo an
15. alog audio signal a converted digital audio S PDIF signal and RS 232 control commands The unidirectional TxD RS 232 interface makes it possible to control virtually any devices over a transmission range of more than 300ft more than 100m over UTP cabling The TP 124 can power or be powered by the TP 123 transmitter over the same CAT 5 cable In addition the TP 124 features e Level and EQ control for the XGA signals e The capability to change the polarity of decoding H and V Sync e 24 bit 48kHz S PDIF digital audio that supplies the highest quality audio e Is 12V DC fed This section describes the topside of the TP 124 XGA Audio Data Line Receiver The underside of the TP 124 is described in section 6 2 2 Figure 11 and Table 10 define the topside of the TP 124 XGA Audio Data Line Receiver 0000 0000 So Analog S PDIF To Of m r 4 KRAMER TOOLS XGA OUT LEIN R232 Auslo OUT 12v0c XGA Audio Data Line Receiver TP 124 d dod Figure 11 TP 124 XGA Audio Data Line Receiver Topside 1 The underside is identical on the TP 124 and TP 122 15 Your TP 123 TP 124 Table 10 TP 124 XGA Audio Data Line Receiver Topside Features Feature Function Al 12V DC 12V DC connector for powering the unit 2 O S PDIF RCA connector Connects to the digital audio acceptor 3 2 3 ANALOG 3 5mm mini jack Connects to the analog audio acceptor
16. contact name company address and a description of the problem s 3 For the name of the nearest Kramer authorized service center consult your authorized dealer LIMITATION OF IMPLIED WARRANTIES All implied warranties including warranties of merchantability and fitness for a particular purpose are limited in duration to the length of this warranty EXCLUSION OF DAMAGES The liability of Kramer for any effective products is limited to the repair or replacement of the product at our option Kramer shall not be liable for 1 Damage to other property caused by defects in this product damages based upon inconvenience loss of use of the product loss oftime commercial loss or 2 Any other damages whether incidental consequential or otherwise Some countries may not allow limitations on how long an implied warranty lasts and or do not allow the exclusion or limitation of incidental or consequential damages so the above limitations and exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from place to place NOTE All products returned to Kramer for service must have prior approval This may be obtained from your dealer This equipment has been tested to determine compliance with the requirements of EN 50081 Electromagnetic compatibility EMC generic emission standard Part 1 Residential commercial and light industry EN 50082 Electromagnetic compatibil
17. ctor for powering the unit 2 AUDIO IN 3 5mm mini jack Connects to the audio source 3 LINE OUT RJ 45 connector Connects to the LINE IN RJ 45 connector on the TP 122 XGA Audio Line Receiver 4 XGA IN 15 pin HD F connector Connect to the XGA source 5 ON LED Illuminates when receiving power 1 Using a UTP CAT 5 cable with RJ 45 connectors at both ends the PINOUT is defined in Table 12 and Figure 14 9 Your TP 121 TP 122 6 1 1 The TP 121 Internal Polarity Switches Figure 6 and Table 5 define the internal sync polarity switches inside the TP 121 Note that you need to open the TP 121 unit to gain access to the Vs and Hs Polarity switches After setting the switches close the TP 121 unit a R24 R27 Vs Hs POLARITY Figure 6 TP 121 Internal Polarity Switches Table 5 Features of the TP 121 Internal Polarity Switches Feature Function VS Switch Slide the switch down to set the V SYNC to negative polarity NEG slide the switch up to set the V SYNC to its input polarity NORM HS Switch Slide the switch down to set the H SYNC to negative polarity NEG slide the switch up to set the H SYNC to its input polarity NORM 6 2 Your TP 122 XGA Audio Line Receiver This section describes the topside see section 6 2 1 and the underside see section 6 2 2 of the TP 122 XGA Audio Line Receiver 6 2 1 Your TP 122 XGA Audio Line Receiver Topside The TP 122
18. e subject to change without notice 2 With 60m CAT 5 cable 3 For the TP 104 Transmitter TP 120 Receiver SETUP 4 The HD resolutions apply to the HD version of the machine 5 For the PT 110 to TP 105 to TP 120 Receiver SETUP 27 Technical Specifications Table 16 Technical Specifications of the TP 121 TP 122 TP 123 TP 124 TP 121 TP 122 TP 123 TP 124 INPUTS VIDEO 1 1 RJ 45 LINE IN VIDEO 1 1 RJ 45 LINE IN VGA UXGA ona connector VGA UXGA on a connector 15 pin HD 15 pin HD connector connector AUDIO 1 audio AUDIO 1 audio ANALOG 3 5mm ANALOG 3 5mm mini jack mini jack OUTPUTS 1 RJ 45 OUT VIDEO 1 1 RJ 45 OUT VIDEO 1 connector VGA UXGA on a connector VGA UXGA on a 15 15 pin HD pin HD connector connector AUDIO AUDIO 1 audio S PDIF 1 audio S PDIF RCA connector RCA connector 1 audio ANALOG 1 audio ANALOG 3 5mm mini jack 3 5mm mini jack MAX OUTPUT LEVEL VIDEO 1V VIDEO 1V AUDIO 2 5V AUDIO 2 5V CONTROLS Level 7 5dB to RS 232 2 PIN RS 232 2 PIN 4 4dB Terminal Block Terminal Block EQ 0dB to Level 7 5dB to 33dBm 130m 4 4dB 50MHz EQ 0dB to 33dBm 130m 50MHz BANDWIDTH 3dB AUDIO 20Hz 20kHz 0 5dB S N RATIO VIDEO 58dB unweighted 68 3dB 5MHz weighted AUDIO lt 80dB TOTAL GAIN AUDIO Analog analog 0dB Analog SPDIF 12dBFS COUPLING AC TND N AUDIO lt 0 01 POWER SOURCE 12V DC 130mA TP 121 12V DC 130mA TP 12
19. echnical Specifications Table 14 includes the technical specifications of the TP 104 Table 15 includes the technical specifications of the TP 105 and Table 16 includes the technical specifications of the TP 121 TP 122 TP 123 and TP 124 Table 14 Technical Specifications of the TP 104 and the TP 104HD TP 104 INPUTS 1 VGA UXGA on a 15 pin HD connector OUTPUTS 4 RJ 45 OUT connectors MAX OUTPUT LEVEL 1 4Vpp BANDWIDTH 3dB gt 150MHz up to 1080p DIFF GAIN 3 2 DIFF PHASE 0 5Deg K FACTOR lt 0 05 S N RATIO 80dB CONTROLS EQ 0 to 33dB LEVEL 7 5dB to 4 4dB COUPLING AC POWER SOURCE 12V DC 180mA DIMENSIONS 12 1cm x 7 18cm x 2 42cm 4 76 x 2 83 x 0 95 W D H WEIGHT 0 3kg 0 67lbs approx ACCESSORIES Power supply Table 15 Technical Specifications of the TP 105 and the TP 105 HD TP 105 INPUTS 1 RJ 45 OUT connector OUTPUTS 2 RJ 45 OUT connectors MAX OUTPUT LEVEL 1 6Vpp BANDWIDTH 3dB Appropriate for VGA UXGA up to 1080p DIFF GAIN 3 7 DIFF PHASE 0 5Deg K FACTOR lt 0 05 S N RATIO 69dB CONTROLS EQ 0 to 4 4dB 50MHz LEVEL 5 5dB to 1 4dB COUPLING AC POWER SOURCE 12V DC 220mA DIMENSIONS 12 1cm x 7 18cm x 2 42cm 4 76 x 2 83 x 0 95 W D H WEIGHT 0 3kg 0 67lbs approx ACCESSORIES Power supply 1 Specifications ar
20. fer to the separate user manual PT 110 WP 110 PT 120 TP 120 which can be downloaded at http www kramerelectronics com 2 Via UTP cabling with a range of more than 300ft gt 100m For details of how to wire a CAT 5 LINE IN LINE OUT RJ 45 connector see section 8 1 3 Use a screwdriver to carefully rotate the trimmer adjusting the appropriate level 4 By default both switches are set down for negative V SYNC and H SYNC polarity 23 Configuring a 1 4 XGA to TP Transmitter Receiver DA Computer Graphics Source Display 1 Figure 17 Configuring a 1 4 XGA to Twisted Pair Transmitter Receiver DA 24 KRAMER SIMPLE CREATIVE TECHNOLOGY Configuring a TP 105 CAT 5 Line Driver DA 11 Configuring a TP 105 CAT 5 Line Driver DA You can connect the TP 105 CAT 5 Line Driver DA using a PT 110 XGA Line Transmitter and two TP 120 XGA Line Receiver units to transmit a computer graphics signal to two displays via long line CAT 5 UTP cabling To connect the TP 105 as the example in Figure 17 illustrates do the following 1 On the PT 110 connect the Computer graphics source to the XGA INPUT 15 pin HD F connector LINE OUTPUT RJ 45 connector to the INPUT RJ 45 connector on the TP 105 On the TP 105 connect the OUT 1 RJ 45 connector to the LINE IN RJ 45 on the first TP 120 OUT 2 RJ 45 connector to the LINE IN RJ 45 on the second TP 120 On the two TP 120 units connect the XGA OUT
21. fied or removed or on which the WARRANTY VOID IF TAMPERED sticker has been torn reattached removed or otherwise interfered with 3 Damage deterioration or malfunction resulting from i Accident misuse abuse neglect fire water lightning or other acts of nature ii Product modification or failure to follow instructions supplied with the product iii Repair or attempted repair by anyone not authorized by Kramer iv Any shipment of the product claims must be presented to the carrier v Removalor installation of the product vi Any other cause which does not relate to a product defect vii Cartons equipment enclosures cables or accessories used in conjunction with the product WHAT WE WILL PAY FOR AND WHAT WE WILL NOT PAY FOR We will pay labor and material expenses for covered items We will not pay for the following 1 Removal or installations charges 2 Costs of initial technical adjustments set up including adjustment of user controls or programming These costs are the responsibility of the Kramer dealer from whom the product was purchased 3 Shipping charges HOW YOU CAN GET WARRANTY SERVICE 1 To obtain service on you product you must take or ship it prepaid to any authorized Kramer service center 2 Whenever warranty service is required the original dated invoice or a copy must be presented as proof of warranty coverage and should be included in any shipment of the product Please also include in any mailing a
22. ideo and audio inputs Connect the laptop to the TP 123 via RS 232 cabling TP 124 Connect the video and audio outputs Connect the TP 124 to an RS 232 controllable device onai Connect the TP 123 to the for example TP 124 via the CATS cable Switcher Range gt 300f 2100 meters STP Cable e e o Step 2 Connect the power If required Q Adjust the EQ and LEVEL Q Set the Polarity switches 2 KRAMER SIMPLE CREATIVE TECHNOLOGY Getting Started Step 1 Connect the Machines Quek start its 1 TP 104 Connect a source to the video input TP 104 Connect the OUT connectors from 1 to 4 to up to four XGA receivers TP 120 via CAT5 cabling TP 120 Connect a video output to each receiver Connect the PT 110 to the TP 105 via CATS cabling P 105 TP 105 Connect the OUT connectors 1 and 2 to up to two XGA receivers TP 120 via CATS cabling TP 120 Connect a video output to each receiver Step 2 Connect the power If required O Adjust the EQ and LEVEL Q Set the Polarity switches Overview 3 1 Overview This user manual describes the following Kramer TOOLS e TP 104 TP 104HD XGA Line Transmitter DA is a line transmitter 1 4 DA that receives an XGA signal and transmits it over four CAT 5 cables to appropriate receivers see section 4 e TP 105 TP 105 HD CAT 5 Line Driver DA receives a CAT 5 input and distributes it to two identical outputs see section 5
23. in high resolution signals 4 Use a screwdriver to carefully rotate the trimmer adjusting the appropriate level 5 The underside is identical on the TP 122 and TP 124 6 By default both switches are set down for a negative V SYNC and H SYNC polarity 16 KRAMER SIMPLE CREATIVE TECHNOLOGY Connecting the XGA Audio Line Transmitter Receiver 8 Connecting the XGA Audio Line Transmitter Receiver You can use the TP 121 and TP 122 to configure an XGA Audio Line to Twisted Pair Transmitter and Receiver system To connect the TP 121 XGA Audio Line Transmitter with the TP 122 XGA Audio Line Receiver as the example in Figure 13 illustrates do the following 1 On the TP 121 connect the XGA source for example a laptop s graphics card to the XGA INPUT 15 pin HD F connector and an audio source to the AUDIO IN 3 5mm mini jack for example using a Kramer C GMA GMA cable VGA 15 pin HD M Audio jack to VGA 15 pin HD M Audio jack 1 Alternatively you can connect an XGA source to the XGA INPUT 15 pin HD F connector and a separate audio source to the AUDIO IN 3 5mm mini jack On the TP 122 connect the XGA OUT 15 pin HD F connector to the XGA acceptor for example a display and connect the AUDIO OUT S PDIF RCA connector to the digital audio acceptor for example an AV Receiver and the ANALOG 3 5mm mini jack to the analog audio acceptor for example a stereo audio recorder Connect the LINE OUTPUT RJ 45 con
24. ine Transmitter DA and not only computer graphics signals for example from a PT 110 as Figure 18 illustrates 2 Using a UTP CAT 5 cable with RJ 45 connectors at both ends the PINOUT is defined in Table 12 and Figure 14 3 Insert a screwdriver into the hole and carefully rotate it to trim the level 8 KRAMER SIMPLE CREATIVE TECHNOLOGY Your TP 121 TP 122 6 1 KRAMER TOOLS XGA Audio Line Transmitter TP 121 Your TP 121 TP 122 This section defines the TP 121 XYGA Audio Line Transmitter see section 6 1 and the TP 122 XGA Audio Line Receiver see section 6 2 Your TP 121 XGA Audio Line Transmitter The TP 121 is an XGA audio stereo line transmitter that receives an XGA signal and an unbalanced stereo analog audio signal and transmits them over CAT 5 cable to a TP 122 receiver converting the unbalanced stereo analog audio signal to digital audio S PDIF stream before transmitting thus preserving the quality of the audio signal In particular the TP 121 e Has a transmission range of more than 300ft more than 100m and a 20kHz audio bandwidth with an S N ratio that exceeds 80dB on the same transmission range e Can power or be powered by the receiver over the same CAT 5 cable e Is 12V DC fed Figure 5 and Table 4 define the TP 121 Figure 5 TP 121 XGA Audio Line Transmitter Table 4 TP 121 XGA Audio Line Transmitter Features Feature Function 1 12V DC 12V DC conne
25. is an XGA audio line receiver that receives the coded CAT 5 signal transmitted by a TP 121 decodes it and converts it to XGA stereo analog and S PDIF digital audio outputs The TP 122 with a TP 121 allows an operation range of more than 300ft more than 100m over standard CAT 5 cable 1 By default both switches are set down for a negative V SYNC and H SYNC polarity 2 The underside is identical on the TP 122 and TP 124 10 KRAMER SIMPLE CREATIVE TECHNOLOGY Your TP 121 TP 122 In addition the TP 122 e Can power or be powered by the transmitter over the same CAT 5 cable e Can change the polarity of decoding H and V Sync for video e Includes EQ and level controls e Is 12V DC fed Figure 7 and Table 6 define the TP 122 XGA Audio Line Receiver topside XGA OUT KRAMER TOOLS LINE IN ANALOG S PDIF XGA Audio Line Receiver LeveL EQ Figure 7 TP 122 XGA Audio Line Receiver Topside Table 6 TP 122 XGA Audio Line Receiver Topside Features Feature Function 1 12V DC 12V DC connector for powering the unit 2 AUDIO S PDIF RCA connector Connects to the digital audio acceptor 3 OUT ANALRA 3 5mm mini Connects to the analog audio acceptor jaci 4 LINE IN RJ 45 connector Connects to the TP 121 or the TP 1047 5 XGA OUT 15 pin HD F connector Connects to the XGA acceptor 6 LINK LED Iluminates when receiving the correct input signal 7 LEVEL trimmer Adjusts the
26. ity EMC generic immunity standard Part 1 Residential commercial and light industry environment CFR 47 FCC Rules and Regulations Part 15 Radio frequency devices Subpart B Unintentional radiators CAUTION amp Servicing the machines can only be done by an authorized Kramer technician Any user who makes changes or modifications to the unit without the expressed approval of the manufacturer will void user authority to operate the equipment Use the supplied DC power supply to feed power to the machine Please use recommended interconnection cables to connect the machine to other components FCC and CE approved using STP cable for twisted pair products 29 For the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions comments and feedback Safety Warning Disconnect the unit from the power supply before opening servicing Caution ROUT Kramer Electronics Ltd Web site www kramerelectronics com E mail info kramerel com P N 2900 000037 REV 9
27. lly rotate the trimmer adjusting the appropriate level 5 By default both switches are set down for negative V SYNC and H SYNC polarity 20 KRAMER SIMPLE CREATIVE TECHNOLOGY Connecting the XGA Audio Data Line Transmitter Receiver Range gt 300ft gt 100 meters STP Cable Display RS 232 Controllable Device for example Switcher AV Receiver Figure 15 Connecting the XGA Audio Data Line Transmitter Receiver System 21 Connecting the XGA Audio Data Line Transmitter Receiver 9 1 Controlling via RS 232 for example using a PC Prepare an RS 232 cable with a 9 pin D sub connector at one end and a 2 PIN terminal block connector at the other end as defined in Figure 16 and Table 13 PC Controller to TP 123 PIN 5 Connected to GND PIN 3 Connected to RxD To PC DB9F TP 124 to Controlled Unit PIN 5 Connected to GND PIN 2 Connected to TxD To PC DB9F Figure 16 RS 232 PINOUT Connection Table 13 RS 232 PINOUT Connection Connect this PIN on the To this PIN on the Terminal Block 9 pin D sub Connector Connector TxD PIN 2 RxD PIN 3 GND PIN 5 22 KRAMER SIMPLE CREATIVE TECHNOLOGY Configuring a 1 4 XGA to TP Transmitter Receiver DA 10 Configuring a 1 4 XGA to TP Transmitter Receiver DA You can use the TP 104 XGA Line Transmitter DA with the TP 120 XGA Line Receiver to configure a 1 4 XGA to Twisted Pair DA system To connec
28. nector on the TP 121 to the LINE IN RJ 45 connector on the TP 122 via UTP cabling with a range of more than 300ft gt 100m see section 8 1 Connect the 12V DC power adapter to the power socket and connect the adapter to the mains electricity on both the TP 121 and the TP 122 The signal from the XGA source is transmitted via CAT 5 cable decoded and converted at the XGA OUT 15 pin HD F connector to the XGA acceptor On the TP 122 Adjust the video output signal level and or cable compensation equalization level if required Ifnecessary set the H SYNC and V SYNC switches on the underside 1 Not supplied The complete list of Kramer cables is on our Web site at http www kramerelectronics com 2 If you cannot connect the power to both the TP 121 and TP 122 you can just connect the power to the TP 122 3 Use a screwdriver to carefully rotate the trimmer adjusting the appropriate level 4 By default both switches are set down for negative V SYNC and H SYNC polarity Connecting the XGA Audio Line Transmitter Receiver Computer Graphics Source Display Stereo Audio Recorder AV Receiver Figure 13 Connecting the XGA Audio Line Transmitter Receiver System 18 KRAMER SIMPLE CREATIVE TECHNOLOGY Connecting the XGA Audio Data Line Transmitter Receiver 8 1 Wiring the CAT 5 LINE IN LINE OUT RJ 45 Connectors Table 12 and Figure 14 define the UTP CAT 5 PINOUT using a straight pin
29. onics com Also see the example illustrated in Figure 17 3 By default both switches are set to NORMAL 4 Downward syncs Your TP 105 TP 105 HD CAT 5 Line Driver DA 5 Your TP 105 TP 105 HD CAT 5 Line Driver DA The TP 105 receives a CAT 5 input and distributes it to two identical outputs In particular the TP 105 e Has a transmission range of more than 300ft more than 100m over UTP cabling e Includes EQ and level controls and is 12V DC fed Figure 4 and Table 3 define the TP 105 CATS Line Driver DA Figure 4 TP 105 CAT 5 Line Driver DA Table 3 TP 105 CAT 5 Line Driver DA Features Feature Function 1 12V DC 12V DC connector for powering the unit 2 OUT 2 RJ 45 connector Connects to the LINE IN RJ 45 connector on the TP 120 XGA Line Receiver 3 OUT 1 RJ 45 connector Connects to the LINE IN RJ 45 connector on the TP 120 XGA Line Receiver 4 INPUT RJ 45 connector Connects to the LINE OUT RJ 45 connector on the PT 110 XGA Line Transmitter 5 EQ trimmer Adjusts the video EQ equalization compensation 6 LEVEL trimmer Adjusts the video signal level 7 ON LED llluminates when receiving power 1 The TP 105HD identified by a sticker on its underside is identical in appearance to the TP 105 However the TP 105HD can also receive HD signals high definition resolutions 480p 576p 720p 1080i and 1080p for example from a TP 112HD XGA HD L
30. t the TP 104 to four TP 120 units as the example in Figure 17 illustrates do the following 1 On the TP 104 connect the XGA source for example a computer graphics source to the XGA INPUT 15 pin HD F connector and connect the line output RJ 45 connector OUT to the LINE IN RJ 45 connector on the TP 120 Unit I OUT 2 to the LINE IN RJ 45 connector on the TP 120 Unit II OUT 3 to the LINE IN RJ 45 connector on the TP 120 Unit III OUT 4 to the LINE IN RJ 45 connector on the TP 120 Unit IV 2 On the four TP 120 units connect the XGA OUT 15 pin HD F connector of Unit I to the XGA acceptor for example Display 1 XGA OUT 15 pin HD F connector of Unit II to the XGA acceptor for example Display 2 XGA OUT 15 pin HD F connector of Unit III to the XGA acceptor for example Display 3 XGA OUT 15 pin HD F connector of Unit IV to the XGA acceptor for example Display 4 3 On each of the five Kramer TOOLS connect the 12V DC power adapter to the power socket and connect the adapter to the mains electricity The signal from the XGA source is transmitted via the four CAT 5 cables decoded and converted at the each of the XGA OUT 15 pin HD F connectors to the XGA acceptors 4 On each of the five Kramer TOOLS Adjust the video output signal level and or cable compensation equalization level if required Ifnecessary on the TP 120 units set the H SYNC and V SYNC switches on the underside 1 Re
31. ttp www kramerelectronics com Alternatively you can connect an XGA source to the XGA IN 15 pin HD F connector and a separate audio source to the AUDIO IN 3 5mm mini jack 19 Connecting the XGA Audio Data Line Transmitter Receiver the TP 123 RS 232 port 2 On the TP 124 connect The XGA OUT 15 pin HD F connector to a display The S PDIF Audio OUT RCA connector to a digital AV Receiver leave the ANALOG Audio OUT 3 5mm mini jack unconnected An RS 232 cable with a 2 PIN terminal block connector at one end to the TP 124 RS 232 port and a 9 pin D sub connector at the other end to the RS 232 port on an RS 232 controllable device for example a switcher 3 Connect the Line OUT RJ 45 connector on the TP 123 to the LINE IN RJ 45 connector on the TP 124 via UTP cabling with a range of more than 300ft gt 100m 4 Connect the 12V DC power adapter to the power socket and connect the adapter to the mains electricity on both the TP 123 and the TP 124 5 On the TP 124 Adjust the video output signal level and or cable compensation equalization level if required Ifnecessary set the H SYNC and V SYNC switches on the underside 1 As defined in Figure 16 and Table 13 2 For details of how to wire a CAT 5 LINE IN LINE OUT RJ 45 connector see section 8 1 3 If you cannot connect the power to both the TP 123 and TP 124 you can just connect the power to any one unit 4 Use a screwdriver to carefu
32. wering the unit 2 OUT 4 RJ 45 connector Connects to the LINE IN RJ 45 connector on the TP 122 XGA Audio Line Receiver or the TP 120 XGA Line Receiver 3 OUT 3 RJ 45 connector Connects to the LINE IN RJ 45 connector on the TP 122 XGA Audio Line Receiver or the TP 120 XGA Line Receiver 4 OUT 2 RJ 45 connector Connects to the LINE IN RJ 45 connector on the TP 122 XGA Audio Line Receiver or the TP 120 XGA Line Receiver 5 OUT 1 RJ 45 connector Connects to the LINE IN RJ 45 connector on the TP 122 XGA Audio Line Receiver or the TP 120 XGA Line Receiver 6 INPUT 15 pin HD F connector Connect to the XGA source 7 ON LED Illuminates when receiving power Figure 3 and Table 2 define the TP 104 and TP 104HD underside panel NORMAL NEGATIVE Figure 3 TP 104 Underside Panel Table 2 TP 104 Underside Panel Features Feature Function 1 VS Switch Slide the switch up to NORMAL to retain the polarity Slide the switch down to change the VS polarity to NEGATIVE polarity 2 HS Switch Slide the switch up to NORMAL to retain the polarity Slide the switch down to change the HS polarity to NEGATIVE polarity 1 Using a UTP CAT 5 cable with RJ 45 connectors at both ends the PINOUT is defined in Table 12 and Figure 14 2 Refer to the separate user manual PT 110 WP 110 PT 120 TP 120 which can be downloaded at http www kramerelectr