Home
Onyx 2121
Contents
1. Slim Medical Panel PC ONY X 2121 1 2 Features e 22 1366x768 TFT LCD Display e Easy To Use Compact Simple Design e Fanless Zero Noise e 1000 1 Contrast Wide View Angle e 250nits High Brightness e Intel Atom D525 1 8GHz Processor e 5 wire Resistive Touch Screen e 802 11 b g n Wireless LAN Optional e Weight 6 4 Kg Thickness 70 mm Slim Medical Panel PC ONYX 2121 1 3 Specification Hardware Specifications Displa 22 1366x768 TFT LCD System 204 pin DDRIII SODIMM x 2 Max 4GB Memory CPU Board Intel Atom D525 1 8GHz Dual Core Processor Drive Bay 2 5 SATA Hard Disk Drive SSD Expansion Mini Card x 2 Button Brightness Sound Power SW yo USB 2 0x 6 Isolated RS 232 x 2 patient connection Isolated Gigabit LAN x 2 patient connection Line out Mic in Speaker x 2 3W Power DC 24V Requirement LCD Specifications Display Type 22 color TFT LCD Max Resolution 1366 x 768 Max Colors 16 7M Luminance cd m2 250 TYP Viewing Angle 170 H 160 V Slim Medical Panel PC ONY X 2121 Contrast Ratio 1000 1 Brightness Control Back Light Life Time 30 000 Hrs Note All ONYX s LCD products are manufactured with High precision technology However there are a small number of defective pixels in all LCD panels that are not able to change
2. the computer When you clean any single part or component for the computer please read and understand the details below fully 1 Never spray or squirt the liquids directly onto any computer component If you need to clean the device please rub it with a piece of dry cloth 2 Be cautious of the tiny removable components when you use a vacuum cleaner to absorb the dirt on the floor 3 Turn the system off before you start to clean up the component or computer 4 Never drop the components inside the computer or get circuit board damp or wet 5 Be cautious of all kinds of cleaning solvents or chemicals when you use it for the sake of cleaning Some individuals may be allergic to the ingredients 6 Try not to put any food drink or cigarette around the computer Appendix A Miscellanea A 2 Slim Medical Panel PC ONYX 2121 A 2 Cleaning tools Although many companies have created products to help improve the process of cleaning your computer and peripherals users can also use household items to clean their computers and peripherals Below is a listing of items you may need or want to use while cleaning your computer or computer peripherals Keep in mind that some components in your computer may only be able to be cleaned using a product designed for cleaning that component if this is the case it will be mentioned in the cleaning tips e Cloth A piece of cloth is the best tool to use when rubbing up a component Althoug
3. 2121 Below Table for China RoHS Requirements ONYX Panel PC Workstation 6 8 NAS Pb Hg Cd Cr VI PBB PBDE O O O O O x O O O O O SERES RAR NB x O O O O O x O O O O O x O O O O O X O O O O O X O O O O O x O O O O O x O O O O O SACS RIA ESTE SJ T 11363 2006 X SJ T 11363 2006 PS ree OUTER ee Slim Medical Panel PC ONY X 2121 Contents Chapter 1 General Information introdguction 5 ail 141 1 2 Features dd 1 2 1 3 Specification ooooooooo oma 1 3 1 4 Dimension nnmnnn 1 7 Chapter 2 Hardware Installation 2 1 Safety Precautions eese 2 1 2 2 A Quick Tour of the 2121 2 2 2 3 VESA Mounting HoleS eese 2 4 Chapte
4. extra moisture with a dry cloth Appendix A Miscellanea A 4 Slim Medical Panel PC ONYX 2121 A 3 Scrap Computer Recycling If the computer equipments need the maintenance or are beyond repair we strongly recommended that you should inform us as soon as possible for the suitable solution For the computers that are no longer useful or work well please contact with worldwide distributors for recycling The worldwide distributors show on the following website http www onyx healthcare com tw Contact php Note Follow the national reguirements to dispose unit Appendix A Miscellanea A 5
5. Slim Medical Panel PC ONY X 2121 ONYX 2121 21 5 Intel Atom D525 Dual Core Processor High Brightness Slim Medical Panel PC ONYX 2121 Manual June 2013 Slim Medical Panel PC ONY X 2121 Copyright Notice This document is copyrighted 2012 All rights are reserved The original manufacturer reserves the right to make improvements to the products described in this manual at any time without notice No part of this manual may be reproduced copied translated or transmitted in any form or by any means without the prior written permission of the original manufacturer Information provided in this manual is intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use nor for any infringements upon the rights of third parties which may result from its use The material in this document is for product information only and is subject to change without notice While reasonable efforts have been made in the preparation of this document to assure its accuracy ONYX assumes no liabilities resulting from errors or omissions in this document or from the use of the information contained herein ONYX reserves the right to make changes in the product design without notice to its users Slim Medical Panel PC ONY X 2121 Acknowledgments e Intel Atom D525 is registered trademark of Intel Corporation e IBM PC AT are trademarks of International Business Machines Corpora
6. c 50 60 Hz 1 8 0 8A Touch Screen Type 5 wire Analog Resistive Interface USB Interface Resolution 2048 x 2048 Light Transmission gt 80 2 Life Time 35 million times Slim Medical Panel PC ONYX 2121 1 4 Dimension ONYX 2121 a ERR Nal wai Unit mm Slim Medical Panel PC NI Chapter Hardware Installation Slim Medical Panel PC ONY X 2121 2 1 Safety Precautions Warning Always completely disconnect the power cord from your board whenever you are working on it Do not make connections while the power is on because a sudden rush of power can damage sensitive electronic components Do not make connections while the power is on because a sudden rush of power can damage sensitive electronic components To avoid risk of electric shock this equipment must only be connected to a supply mains with protective earth Do not modify this equipment without authorization of the manufacturer Always ground yourself to remove any static charge before touching the board Modern electronic devices are very sensitive to static e electric charges Use a grounding wrist strap at all times Place all electronic components on a static dissipative surface or in a static shielded bag when they are not in the chassis Caution Chapter 2 Hardware Insta
7. color This is a normal occurrence for all LCD displays from all manufacturers and should not be noticeable or objectionable under normal operation ONYX LCD panels are qualified for industry standard conditions in the following total 7 dead pixels on a screen or if there are 3 within 1 inch square area of each other on the display Mechanical Specifications Architecture Close frame Front Bezel Plastic bezel with resistive touch screen Color White Mounting Holder 75 100mm Construction 3mm ABS PC TYPE Plastic housing Dimension 21 5 x 13 8 x 2 8 545mm x 351mm x 70mm W x Hx D Packing Filler PE Power Supply Specifications Input Voltage ELJINTEK INC GMPU70A 6 100 240 Vac 50 60 Hz 1 8 0 8A Slim Medical Panel PC ONY X 2121 Output Voltage ELJINTEK INC GMPU70A 6 24V 2 91 70W 61320 Calculated Hours 7 years Environmental Specifications Operating Temperature 10 C to 40 C 50 F 104 F Operating Humidity 5 to 95 RH non condensing Storage Temperature 20 C to 60 C 4 F 140 F Storage Humidity 10 to 90 40 C non condensing Vibration 0 5G 5 500Hz Random operation Shock 15G peak acceleration 11 msec duration operation Drop 76cm 1 Corner 3 Edge 6 Surface EMI Safety CE FCC Class B EN 60601 1 Noise Zero noise Input Power Rating ELJINTEK INC GMPU70A 6 100 240 Va
8. er open the equipment For safety reasons only qualified Slim Medical Panel PC ONY X 2121 service personnel should open the equipment 14 If any of the following situations arises get the equipment checked by service personnel a The power cord or plug is damaged b Liquid has penetrated into the equipment c The equipment has been exposed to moisture d The equipment does not work well or you cannot get it to work according to the users manual e The equipment has been dropped and damaged f The equipment has obvious signs of breakage 15 DO NOT LEAVE THIS EQUIPMENT IN AN UNCONTROLLED ENVIRONMENT WHERE THE STORAGE TEMPERATURE IS BELOW 20 C 4 F OR ABOVE 60 C 140 F IT MAY DAMAGE THE EQUIPMENT 16 External equipment intended for connection to signal input output or other connectors shall comply with relevant UL IEC standard e g UL 60950 1 for IT equipment and ANSI AAMI ES 60601 1 IEC 60601 1 series for systems shall comply with the standard IEC 60601 1 1 Safety requirements for medical electrical systems Equipment not complying with ANSI AAMI ES 60601 1 shall be kept outside the patient environment as defined in the standard Caution It may cause the danger of explosion if battery is incorrectly replaced Replace only with same or equivalent type recommended by the manufacturer Slim Medical Panel PC ONY X 2121 Classification 1 Degree of production against electric shock Not c
9. h paper towels or tissues can be used on most hardware as well we still recommend you to rub it with a piece of cloth e Water or rubbing alcohol You may moisten a piece of cloth a bit with some water or rubbing alcohol and rub it on the computer Unknown solvents may be harmful to the plastics parts e Vacuum cleaner Absorb the dust dirt hair cigarette particles and other particles out of a computer can be one of the best methods of cleaning a computer Over time these items can restrict the airflow in a computer and cause circuitry to corrode Appendix A Miscellanea A 3 Slim Medical Panel PC ONYX 2121 e Cotton swabs Cotton swaps moistened with rubbing alcohol or water are excellent tools for wiping hard to reach areas in your keyboard mouse and other locations e Foam swabs Whenever possible it is better to use lint free swabs such as foam swabs Note We strongly recommended that you should shut down the system before you start to clean any single components Please follow the steps below 1 Shut down the panel PC and then disconnect the power cord before cleaning 2 Do not spray any liquid detergent directly on the panel PC or use any detergent containing flammable material to clean the panel PC The surface needs to be cleaned with neutral detergent other than any acidic or alkali solutions 3 Wipe the surface using a clean cellulose sponge or soft cloth dampened with detergent and remove any
10. ilding East Zhongshan Road Nanjing China Tel 86 025 58859841 Fax 86 025 85088070 Email Jonwang onyx healthcare com Onyx Healthcare Singapore PTE LTD 57 Genting Lane 07 00 Singapore 349564 Tel 65 67498749 Fax 65 67461595 Email sgsales onyx healthcare com Slim Medical Panel PC ONYX 2121 Safety amp Warranty 1 Read these safety instructions carefully Keep this user s manual for later reference Disconnect this equipment from any AC outlet before cleaning Do not use liquid or spray detergents for cleaning Use a damp cloth 4 For pluggable equipment the power outlet must be installed near the equipment and must be easily accessible Keep this equipment away from humidity Put this equipment on a reliable surface during installation Dropping it or letting it fall could cause damage 7 The openings on the enclosure are for air convection Protect the equipment from overheating DO NOT COVER THE OPENINGS 8 Make sure the voltage of the power source is correct before connecting the equipment to the power outlet 9 Position the power cord so that people cannot step on it Do not place anything over the power cord 10 All cautions and warnings on the equipment should be noted 11 If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient over voltage 12 Never pour any liquid into an opening This could cause fire or electrical shock 13 Nev
11. lassified 2 Degree of protection against the ingress of water 3 Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide 4 Mode of operation Continuous 5 Type of protection against electric shock Class equipment 6 No Applied part No AP APG Slim Medical Panel PC ONY X 2121 FCC Warning This device complies with Part 18 FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Slim Medical Panel PC ONY X 2121 UL Module Description ile Onyx 2121 AC modules are developed to suitable for the Classification Mark C US requirement Slim Medical Panel PC ONY X 2121 Safety Symbol Description The following safety symbols are the further explanations for your reference Medical equipment with respect to electric oe shock fire and mechanical hazards only in cus accordance with ANSI AAMI ES 60601 1 2005 AND CAN CSA C22 2 No 60601 1 08 Attention consult ACCOMPANYING i DOCUMENTS Ground wire Protective Ground wire Medical equipment with respect to TAY electric shock fire and mechanical C US hazards only in accordance with UL 60601 1 and CAN CSA C22 2 NO 601 1 Slim Medical Panel PC ONY X
12. llation 2 1 Slim Medical Panel PC ONY X 2121 2 2 A Quick Tour of the ONYX 2121 Before you start to set up the ONYX 2121 take a moment to become familiar with the locations and purposes of the controls drives connections and ports which are illustrated in the figures below When you place the ONYX 2121 upright on the desktop its front panel appears as shown in Picture 2 1 Picture 2 1 Front View of the Slim Medical Panel PC When you turn the Slim Medical Panel PC around and look at its rear cover the sunken I O section is at the bottom of the PC as shown in Picture 2 2 The I O section includes various 1 ports including DC in Serial ports VGA Ethernet USB Only assemble with the Mini card Chapter 2 Hardware Installation 2 2 Smart Healthcare Slim Medical Panel PC ONY X 2121 Line out Mic in 2 x Isolated RS232 COM Port DC Power Input Ground 6x USB 20 2 x Isolated Gigabit LAN Figure 2 2 Rear view of ONYX 2121 Chapter 2 Hardware Installation 2 3 Slim Medical Panel PC ONYX 2121 2 3 VESA Mounting Holes VESA Screws M4 x 0 7 x 12mm RES f VESA 100 Tino LL S 75 Chapter 2 Hardware Installation 2 4 Smart oatmcaro Slim Medical Panel PC ONY X 2121 Appendix Miscellanea Appendix A Miscellanea A 1 Slim Medical Panel PC ONYX 2121 A 1 General Cleaning Tips You may need the following precautions before you begin to clean
13. r 3 Driver Installation 3 1 Installation 0 3 3 Appendix A Miscellanea General Cleaning TipS A 2 A 2 Cleaning Tools oooooo oom A 3 Scrap Computer Recycling A 5 Slim Medical Panel PC ONY X 2121 Chapter General Information Slim Medical Panel PC ONY X 2121 1 1 Introduction The ONYX 2121 is a Slim Medical Panel PC with Intel Atom D525 1 8GHz Dual Core processor based computer that is designed to serve as a point of care station It is a PC based system with 22 true color TFT LCD display Zero Noise solution integrated multimedia functions make them the perfect platforms to build comprehensive lifestyle computing applications The ONYX 2121 includes all the features of a powerful computer into a slim and attractive chassis ONYX 2121 has 250 nits TFT displays with 1366 x 768 resolution and with 22 LCD respectively Integrating with high brightness LCD is easier to analyze DICOM images It supports 2 5 Hard Disk Drive storage function and one Mini Card slot for WLAN expansion Moreover they feature flexible I O ports such as six USB2 0 two isolated RS 232 and two isolated Gigabit LANs Convenient operation Silent compact mobility and highly integrated multimedia system let you to focus on healthcare utility interactive information displays automation control systems general desktop usage multimedia recreation and other medical requirements
14. tion e Microsoft Windows is a registered trademark of Microsoft Corporation All other product names or trademarks are properties of their respective owners Slim Medical Panel PC ONY X 2121 Packing List Before you begin installing your Slim Medical Panel PC please make sure that the following items have been shipped m ONYX 2121 Slim Medical Panel PC m VESA Screws M4 x 0 7 x 12mm m Utility CD ROM which contains Drivers and Utilities If any of these items are missing or damaged you should contact your distributor or sales representative immediately Headquarters Onyx Healthcare Inc 2F No 135 Ln 235 Baogiao Rd Xindian Dist New Taipei City 231 Taiwan R O C TEL 886 2 8919 2188 FAX 886 2 8919 1699 E mail sales onyx healthcare com http www onyx healthcare com Slim Medical Panel PC ONYX 2121 Worldwide Offices Onyx Healthcare USA Inc 2663 Saturn street Brea CA 92821 USA Tel 1 714 996 1800 Fax 1 714 996 1811 Email usasales onyx healthcare com Onyx Healthcare EUROPE B V Ekkersrijt 4002 5692 DA Son Netherlands Tel 31 0 499 462020 Fax 31 0 499 462010 Email eusales onyx healthcare com Onyx Healthcare Technology GmbH An der Trift65d 63303 Dreieich Germany TEL 49 0 61033 7479 00 Fax 49 0 61033 7479 49 Email eusales onyx healthcare com Slim Medical Panel PC ONYX 2121 Onyx Healthcare Nanjing INC Room 1318 Metallurgy Bu
Download Pdf Manuals
Related Search
Related Contents
Olympus FE-110 Advanced Manual Settings Manual - DALPINO - Lâminas para corte de carne English - Arabic العربية - Service Katalog 2015 OPTIMAX - Little Wonder Conceptronic Lounge ‘n LOOK Cliqcam Garmin iQue 3200 GPS Receiver User Manual THE ERA GT MK I and Mk II Manual de Instruções Copyright © All rights reserved.