1. AO su0755a su0754a Remove Battery CAUTION DAMAGE TO EQUIPMENT OR PERSONNEL e The equipment is heavy Always practice safe lifting techniques adequate for the weight of the equipment e The UPS the battery weighs 41 kg 90 4 Ib e The battery weighs 23 8 kg 52 4 Ib Remove the battery before installing the unit in a rack e Use the battery handle to lift and slide the battery out of the UPS Failure to follow these instructions can result in equipment damage and minor or moderate injury su0758a su0759a 4 Smart UPS X 2000 2200 3000 VA XL Tower Rack Mount 4U su0760a Tower Configuration su0774a su0762a Smart UPS X 2000 2200 3000 VA XL Tower Rack Mount 4U Rack Mount Configuration CAUTION DAMAGE TO EQUIPMENT OR PERSONNEL The equipment is heavy Always practice safe lifting techniques adequate for the weight of the equipment e The UPS the battery weighs 41 kg 90 4 Ib e The battery weighs 23 8 kg 52 4 Ib Remove the battery before installing the unit in a rack e Use the battery handle to lift and slide the battery out of the UPS Failure to follow these instructions can result in equipment damage and minor or moderate injury Tower to rack mount conversion su0583b su0761b su0766a 6 Smart UPS X 2000 2200 3000 VA XL Tower Ra
2. on the UPS are not blocked Allow adequate space for proper ventilation e The battery typically lasts for two to five years Environmental factors impact battery life Elevated ambient temperatures poor quality utility power and frequent short duration discharges will shorten battery life e Connect the UPS power cable directly to a wall outlet Do not use surge protectors or extension cords e The batteries are heavy Remove the batteries prior to installing the UPS in a rack e Always install external battery packs XLBPs at the bottom of the rack The UPS must be installed above the XLBPs e The UPS display interface will recognize as many as 10 external battery packs connected to the UPS However there is no limit to the number of XLBPs that can be used with the UPS e Refer to Specifications in the Operation manual for UPS and battery weight Inventory Inspect the contents upon receipt Notify the carrier and dealer if the unit is damaged Included with all models 1 pair rail cleats 1 pair tower stabilizer brackets Use 8 flat head screws to secure tower stabilizer brackets to the UPS RL 8 pan head screws Ss ip 1 pair rack mount brackets Use 8 flat head screws to secure rack mount brackets to the UPS Use 4 ornamental screws to secure rack mount brackets to the rails Install a cage nut in the rack to secure the top hole of each rack mount bracket in a four post rack eS ETS EX 1 Documentation CD we 1 Pow
3. Arc by Schneider Electric Installation Guide Smart UPS X 2000 2200 3000 XL Tower Rack Mount 4U Important Safety Messages Read the instructions carefully to become familiar with the equipment before trying to install operate service or maintain it The following special messages may appear throughout this manual or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure The addition of this symbol to a Caution product safety label indicates that a hazard exists that can result in injury and product damage if the instructions are not followed The following safety messages may appear throughout this manual to warn of potential hazards 4 CAUTION CAUTION indicates a potentially hazardous situation which if not avoided can result in equipment damage and minor or moderate injury CAUTION CAUTION indicates a potentially hazardous situation which if not avoided can result in equipment damage Safety and General Information Inspect the package contents upon receipt Notify the carrier and dealer if there is any damage Read the Safety Guide supplied with this unit before installing the UPS e Adhere to all local and national electrical codes e This UPS is intended for indoor use only e Do not operate this UPS in direct sunlight in contact with fluids or where there is excessive dust or humidity e Be sure the air vents
4. ck Mount 4U CAUTION DAMAGE TO EQUIPMENT OR PERSONNEL e When installing equipment in a rack always install external battery packs at the bottom of the rack e The UPS should always be installed above the external battery packs in rack or stack configurations Failure to follow these instructions can result in equipment damage and minor or moderate injury Two post rack installation su0773a su0771a Smart UPS X 2000 2200 3000 VA XL Tower Rack Mount 4U su0772a Four post rack installation Use an APC by Schneider Electric four post rail kit To order the rail kit go to the APC by Schneider Electric Web site apc com oO 2 3 g ae CELEELITEITIITT su0777a su0782a UPS Configuration Connect Emergency Power Off feature For instructions on how to connect the Emergency Power Off EPO switch refer to the Operation and Maintenance manual on the Documentation CD supplied Configure controllable outlet groups The outlets on the UPS are configured into groups To utilize the controlled outlet features use the Advanced menus on the display interface and navigate to Main Menu gt Control gt Outlet1 Control 8 Smart UPS X 2000 2200 3000 VA XL Tower Rack Mount 4U Electrical connections CAUTION RISK OF EQUIPMENT DAMAGE e Adhere to all local and national electrical codes e Wiring should be perfo
5. erChute software CD TES Included with models that have factory installed Rack mount support brackets and hardware Network Management Cards 1 pair support Two post racks Four post racks brackets 10 screws 6 screws 6 washers Smart UPS X 2000 2200 3000 VA XL Tower Rack Mount 4U Product Overview Front panel features 6 0 im rs lel gt l pd Sa mme ol ms su0343a Rear panel features SmartSlot Chassis ground screw UPS utility power input Circuit Breaker reset Controllable Outlet Group 1 60000 Controllable Outlet Group 2 2000 VA 120 Vac Low Voltage su0756a Online LED Power ON OFF button On Battery LED Site Wiring Fault LED Replace Battery LED LCD display screen UP DOWN arrow keys ENTER key Esc key Controllable Outlet Group 3 External battery pack connector EPO connector Serial port USB port 3000 VA 120 Vac Low Voltage su0757a Smart UPS X 2000 2200 3000 VA XL Tower Rack Mount 4U 2200 3000 VA 230 Vac High Voltage 3000 VA 208 Vac High Voltage Di o a o LEE 0 ON SI EI
6. rmed by qualified electrician e Always connect the UPS to a grounded outlet Failure to follow these instructions can result in equipment damage Smart UPS X 2000 2200 3000 VA XL Tower Rack Mount 4U su0788a Select models are ENERGY STAR qualified CR For more information go to www apc com site recycle index cfm energy efficiency energy star ENERGY STAR 2013 APC by Schneider Electric APC the APC logo Smart UPS and PowerChute are owned by Schneider Electric Industries S A S or their affiliated companies All other trademarks are property of their respective owners EN 990 4651A 002 03 2013