Home
Black Box FlexPoint 1000BASE-T to 1000BASE-SX, LC
Contents
1. The FlexPoint Gx can be mounted standalone using a wall mounting kit or a DIN rail bracket It can also be rack mounted using a 5 unit shelf or a high density 14 unit FlexPoint Powered Chassis An 18 60VDC power adapter is available for standalone or DIN rail mounted applications Attach the FlexPoint Gx UTP via a category 5 or higher cable to a 1000Base T Ethernet device Attach the FlexPoint Gx fiber via a single mode or multimode as needed cable to a 1000Base X Gigabit Ethernet device make sure to use the correct wavelength source for the model being used The FlexPoint transmit Tx must attach to the receive side on the other device the receive Rx must attach to the transmit DIP Switch Settings F O Auto Negotiation Auto Neg Manual DIP Switch When the FlexPoint Gx is connected to a UTP device and a F O device the F O Auto Negotiation transparently allows the two devices to negotiate Duplex and Pause modes with each other Setting this DIP switch to Auto Neg factory default enables the FlexPoint Gx s F O port to detect the Duplex and Pause modes of the connected F O device The NORMAS OFICIALES MEXICANAS NOM ELECTRICAL SAFETY STATEMENT 1 Todas las instrucciones de seguridad y operaci n deber n ser le das antes de que el aparato el ctrico sea operado 2 Las instrucciones de seguridad y operaci n deber n ser guardadas para referencia futura 3 Todas las advertencias en el aparato el ctrico
2. BLACK BOX LMC1003A R3 LMC1008A R3 Description The FlexPoint Gx converts between 1000Base X Sx Lx Gigabit Ethernet fiber and 1000Base T twisted pair RJ45 UTP cabling The fiber optic F O port supports Auto Negotiation AN which automatically detects and advertises the Duplex and Pause ability of the connected remote device The multimode MM and single mode SM models are described here LMC1003AE R3 LMC1004A R3 LMC1004AE R3 LMC1005A R3 LMC1005AE R3 LMC1006A R3 LMC1006AE R3 LMC1007A R3 LMC1007AE R3 LMC1008AE R3 LMC1009A R3 LMC1009AE R3 LMC1010A R3 LMC1010AE R3 LMC1011A R3 LMC1011AE R3 LMC1012A LMC1012AE FlexPoint Gx CUSTOMER Order toll free in the U S Call 877 877 BBOX SUPPORT outside U S call 724 746 5500 INFORMATION FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com LED Indicators ED Gator Stans boscipion Power ameron Power applied FDX HDX Amber On UTP Ful Duplex i F O Green On Fiber Link A In F O Auto Neg mode Fiber cable connected but Fiber Link disabled due to UTP or return Fiber Link not ready No Fiber Link UTP Green On UTP Link In F O Manual mode w Link Prop UTP cable connected but UTP Link disabled due to loss of Fiber Rx No UTP Link Model LMC1003A
3. port causes the transmit link of the UTP port to be turned off and the loss of a receive link on the UTP port causes the transmit link on the F O port to be turned off This allows the loss of a link to be propagated and detected by SNMP or other managed network devices to which the FlexPoint Gx is connected Only the first loss of a receive link detected by the FlexPoint Gx turns off the transmit link of the other port An additional loss of receive link on the other port has no effect to the FlexPoint Gx The FlexPoint Gx returns to normal operation when the first loss of receive link is restored When set to Link Isolate factory default the generation and detection of link presence is done at each point to point segment Loss of a receive link on any port has no effect on transmit signals of the other port Copyright 2011 Black Box Corporation All rights reserved 1000 Park Drive e Lawrence PA 15055 1018 724 746 5500 e Fax 724 746 0746 2 Precaci n debe ser tomada de tal manera que la tierra fisica y la polarizaci n del equipo no sea eliminada Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos poniendo particular atenci n a los contactos y receptaculos donde salen del aparato 4 El equipo el ctrico debe ser limpiado nicamente de acuerdo a las recomendaciones del fabricante 5 En caso de existir una antena exter
4. R3 LMC1003AE R3 LMC1004A R3 LMC1004AE R3 LMC1005A R3 LMC1005AE R3 LMC1006A R3 LMC1006AE R3 LMC1007A R3 LMC1007AE R3 LMC1008A R3 LMC1008AE R3 LMC1009A R3 LMC1009AE R3 LMC1010A R3 LMC1010AE R3 LMC1011A R3 LMC1011AE R3 LMC1012A LMC1012AE Fiber 850nm MM SC 850nm MM SC 1310nm SM SC 1310nm SM SC 1310nm SM SC 1310nm SM SC 1550nm SM SC 1550nm SM SC 850nm MM MTRJ 850nm MM MTRJ 1310nm SM MTRJ 1310nm SM MTRJ 1310nm SM LC 1310nm SM LC 1310nm SM LC 1310nm SM LC 1550nm SM LC 1550nm SM LC 850nm MM LC 850nm MM LC Power Adapter Notice 1 When using in a stand alone configuration this product is intended to be and must be used only with a Listed Direct Plug In Power Unit marked Class 2 and rated at 9Vdc 1 Amp Specifications Description Protocols UTP Cable Type Fiber Cable Type UTP Connector Type Controls Distance 220m 720 ft 220m 720 ft 10km 6 2 mi 10km 6 2 mi 25km 15 5 mi 25km 15 5 mi 65km 40 4 mi 65km 40 4 mi 220m 720 ft 220m 720 ft 10km 6 2 mi 10km 6 2 mi 10km 6 2 mi 10km 6 2 mi 25km 15 5 mi 25km 15 5 mi 65km 40 4 mi 65km 40 4 mi 220m 720 ft 220m 720 ft 1000Base T UTP to 1000Base X Fiber Converter with Auto Negotiation 802 3ab 1000Base T 1000Base X EIA TIA 568A B Category 5 and higher Multimode 50 125 62 5 125 100 140um Single mode 9 125 um Dual fiber SC LC MT RJ DIP Switches LED Display Power R
5. affect if the FlexPoint Gx is in F O AN mode This DIP switch configures the Duplex capability when the UTP port is Auto Negotiating with the connected UTP device Setting the DIP switch to Full Duplex factory default allows the UTP port to Auto Negotiate to Full Duplex or Half Duplex Setting the DIP switch to Half Duplex forces the UTP port to Auto Negotiate only to Half Duplex UTP Pause Enable Pause Disable DIP Switch This DIP switch has no affect if the FlexPoint Gx is in F O AN mode This DIP switch configures the Pause capability when the UTP is Auto Negotiating with the NORMAS OFICIALES MEXICANAS NOM ELECTRICAL SAFETY STATEMENT 1 Todas las instrucciones de seguridad y operaci n deber n ser le das antes de que el aparato el ctrico sea operado 2 Las instrucciones de seguridad y operaci n deber n ser guardadas para referencia futura 3 Todas las advertencias en el aparato el ctrico y en sus instrucciones de operaci n deben ser respetadas 4 Todas las instrucciones de operaci n y uso deben ser seguidas 5 El aparato el ctrico no deber ser usado cerca del agua por ejemplo cerca de la tina de ba o lavabo s tano mojado o cerca de una alberca etc 6 El aparato el ctrico debe ser usado nicamente con carritos o pedelstales que sean recomendados por el fabricante 7 El aparato el ctrico debe ser montado a la pared o al techo s lo como sea recomendado por el fabricante 8 Servicio E usuari
6. d UTP device based on the modes detected by the F O port Both the FlexPoint Gx and the connected F O device must have their Auto Negotiation enabled for this process to work Setting this DIP switch to Manual will disable the F O port s ability to detect the Duplex and Pause modes of the connected F O device The FlexPoint Gx s UTP port negotiates with the connected UTP device based on the modes configured by the UTP Full Duplex Half Duplex and Pause Enable Pause Disable DIP switches Note that in F O Auto Negotiation AN mode connecting the F O cables before connecting the UTP cables causes the F O LED to blink steadily The blinking LED turns solid when the UTP Link is on Note that when F O Auto Negotiation is in the Enable position all the other DIP switches have no effect when the links are established UTP Full Duplex Half Duplex DIP Switch This DIP switch has no affect if the FlexPoint Gx is in F O AN mode This DIP switch configures the Duplex capability when the UTP port is Auto Negotiating with the connected UTP device Setting the DIP switch to Full Duplex factory default allows the UTP port to Auto Negotiate to Full Duplex or Half Duplex Setting the DIP switch to Half Duplex forces the UTP port to Auto Negotiate only to Half Duplex UTP Pause Enable Pause Disable DIP Switch This DIP switch has no affect if the FlexPoint Gx is in F O AN mode This DIP switch configur
7. de U S call 724 746 5500 INFORMATION FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com Specifications inti 1000Base T UTP to 1000Base X Fiber Description Converter with Auto Negotiation Protocols 802 3ab 1000Base T 1000Base X EIA TIA 568A B UTP Cable Type Category 5 and higher Fiber Cable Type Fiber Connector Type Dual fiber SC LC MT RJ Controls DIP Switches LED Display Power Requirements AC Adapter Input US 120VAC 240mA 60Hz AC Adapter Input Universal 100 250VAC 500mA 50 60Hz DC Adapter Input Model 4384 18 60VDC Optional Dimension WxDxH weight Multimode 50 125 62 5 125 100 140um Single mode 9 125 um W 4 6 x D 3 3 x H 0 85 Compliance UL CE FCC Class A Temperature Operational 0 to 50 C Storage 50 to 80 C T ansing 0 to 95 aide M MTBF firs MTTR 5 min Description The FlexPoint Gx converts between 1000Base X Sx Lx Gigabit Ethernet fiber and 1000Base T twisted pair RJ45 UTP cabling The fiber optic F O port supports Auto Negotiation AN which automatically detects and advertises the Duplex and Pause ability of the connected remote device The multimode MM and single mode SM models are described here Model Fiber Distance LMC1003A R3 850nm MM SC 220m 720 ft LMC1003AE R3 850n
8. equirements AC Adapter Input US 120VAC 240mA 60Hz AC Adapter Input Universal DC Adapter Input Model 4384 Optional Compliance Operational Storage Humidity non condensing MTBF hrs MTTR 100 250VAC 500mA 50 60Hz 18 60VDC W 4 6 x D 3 3 x H 0 85 0 to 95 Up to 10 000 850 000 2 This product should only be used with Black Box Supplied Power Unit WARNING Before inserting the Power Adapter verify that the power on the unit is appropriate for your AC line voltage source Mounting and Cable Attachment The FlexPoint Gx can be mounted standalone using a wall mounting kit or a DIN rail bracket It can also be rack mounted using a 5 unit shelf or a high density 14 unit FlexPoint Powered Chassis An 18 60VDC power adapter is available for standalone or DIN rail mounted applications Attach the FlexPoint Gx UTP via a category 5 or higher cable to a 1000Base T Ethernet device Attach the FlexPoint Gx fiber via a single mode or multimode as needed cable to a 1000Base X Gigabit Ethernet device make sure to use the correct wavelength source for the model being used The FlexPoint transmit Tx must attach to the receive side on the other device the receive Rx must attach to the transmit DIP Switch Settings F O Auto Negotiation Auto Neg Manual DIP Switch When the FlexPoint Gx is connected to a UTP device and a F O device the F O Auto Negotiation transparently allows the
9. es the Pause capability when the UTP is Auto Negotiating with the 12 Precaci n debe ser tomada de tal manera que la tierra fisica y la polarizaci n del equipo no sea eliminada 13 Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos poniendo particular atenci n a los contactos y receptaculos donde salen del aparato 14 El equipo el ctrico debe ser limpiado nicamente de acuerdo a las recomendaciones del fabricante 15 Encaso de existir una antena externa deber ser localizada lejos de las lineas de energia 16 El cable de corriente deber ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo 17 Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilaci n 18 Servicio por personal calificado deber ser provisto cuando A El cable de poder o el contacto ha sido da ado u B Objectos han ca do o l quido ha sido derramado dentro del aparato o C El aparato ha sido expuesto a la lluvia o D El aparato parece no operar normalmente o muestra un cambio en su desempe o o E El aparto ha sido tirado o su cubierta ha sido da ada LMC1003A R3 version 2 040 01019 R31B 3 11 connected UTP device Setting the DIP switch to Pause Enable factory default allows the UTP port to Auto Negotiate to Symmetrical and Asymmetrical Pause Setti
10. ipment This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regu lation of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num irques de las classe A prescrites dans le R glement sur le brouillage radio lectrique publi par le minist re des Communications du Canada FlexPoint Gx s UTP port then negotiates with the connected UTP device based on the modes detected by the F O port Both the FlexPoint Gx and the connected F O device must have their Auto Negotiation enabled for this process to work Setting this DIP switch to Manual will disable the F O port s ability to detect the Duplex and Pause modes of the connected F O device The FlexPoint Gx s UTP port negotiates with the connected UTP device based on the modes configured by the UTP Full Duplex Half Duplex and Pause Enable Pause Disable DIP switches Note that in F O Auto Negotiation AN mode connecting the F O cables before connecting the UTP cables causes the F O LED to blink steadily The blinking LED turns solid when the UTP Link is on Note that when F O Auto Negotiation is in the Enable position all the other DIP switches have no effect when the links are established UTP Full Duplex Half Duplex DIP Switch This DIP switch has no
11. m MM SC 220m 720 ft LMC1004A R3 1310nm SM SC 10km _ 6 2 mi LMC1004AE R3 1310nm SM SC 10km 6 2 mi LMC1005A R3 1310nm SM SC 25km 15 5 mi LMC1005AE R3 1310nm SM SC 25km 15 5 mi LMC1006A R3 1550nm SM SC 65km 40 4 mi LMC1006AE R3 1550nm SM SC 65km 40 4 mi LMC1007A R3 850nm MM MTRJ 220m 720 ft LMC1007AE R3 850nm MM MTRJ 220m 720 ft LMC1008A R3 1310nm SM MTRJ 10km 6 2 mi LMC1008AE R3_ 1310nm SM MTRJ 10km 6 2 mi LMC1009A R3 1310nm SM LC 10km 6 2 mi LMC1009AE R3 1310nm SM LC 10km 6 2 mi LMC1010A R3 1310nm SM LC 25km 15 5 mi LMC1010AE R3 1310nm SM LC 25km 15 5 mi LMC1011A R3 1550nm SM LC 65km 40 4 mi LMC1011AE R3 1550nm SM LC 65km 40 4 mi LMC1012A 850nm MM LC 220m 720 ft LMC1012AE 850nm MM LC 220m 720 ft Power Adapter Notice 1 When using in a stand alone configuration this product is intended to be and must be used only with a Listed Direct Plug In Power Unit marked Class 2 and rated at 9Vdc 1 Amp TRADEMARKS USED IN THIS MANUAL Black Box and the Double Diamon logo are registered trademarks of BB Technologies Inc Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners FEDERAL COMMUNICATIONS COMMISSION AND CANADIAN DEPARTMENT OF COMMUNICATIONS RADIO FREQUENCY INTERFERENCE STATEMENTS This equipment generates uses and can radiate radio frequency en ergy and if not installed and used properly that is in strict accordance
12. na deber ser localizada lejos de las lineas de energia 6 El cable de corriente deber ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo 7 Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilaci n 8 Servicio por personal calificado debera ser provisto cuando A El cable de poder o el contacto ha sido da ado u B Objectos han ca do o l quido ha sido derramado dentro del aparato o C El aparato ha sido expuesto a la lluvia o D El aparato parece no operar normalmente o muestra un cambio en su desempe o o E El aparto ha sido tirado o su cubierta ha sido da ada w LMC1003A R3 version 2 040 01019 R31B 3 11 LED Indicators FDX HDX Amber Blink In F O Auto Neg 1Hz mode Fiber cable connected but Fiber Link disabled due to UTP or return Fiber Link not ready No Fiber Link UTP UTP Link Link Rx In F O Manual mode w Link Prop UTP cable connected but UTP Link disabled due to loss of Fiber Rx Jott No UTP Link BLACK BOX LMC1003A R3 LMC1003AE R3 LMC1004A R3 LMC1004AE R3 LMC1005A R3 LMC1005AE R3 LMC1006A R3 LMC1006AE R3 LMC1007A R3 LMC1007AE R3 LMC1008A R3 LMC1008AE R3 LMC1009A R3 LMC1009AE R3 LMC1010A R3 LMC1010AE R3 LMC1011A R3 LMC1011AE R3 LMC1012A LMC1012AE FlexPoint Gx CUSTOMER Order toll free in the U S Call 877 877 BBOX SUPPORT outsi
13. ng the DIP switch to Pause Disable forces the UTP port to Auto Negotiate only to No Pause Link Prop Link Isolate DIP Switch This DIP switch has no affect if the FlexPoint Gx is in F O AN mode Setting this DIP switch to Link Prop allows the link state to propagate from the UTP port to the F O port and allows the link state to propagate from the F O port to the UTP port The loss of a receive link on the F O port causes the transmit link of the UTP port to be turned off and the loss of a receive link on the UTP port causes the transmit link on the F O port to be turned off This allows the loss of a link to be propagated and detected by SNMP or other managed network devices to which the FlexPoint Gx is connected Only the first loss of a receive link detected by the FlexPoint Gx turns off the transmit link of the other port An additional loss of receive link on the other port has no effect to the FlexPoint Gx The FlexPoint Gx returns to normal operation when the first loss of receive link is restored When set to Link Isolate factory default the generation and detection of link presence is done at each point to point segment Loss of a receive link on any port has no effect on transmit signals of the other port Copyright 2011 Black Box Corporation All rights reserved 1000 Park Drive e Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746
14. o no debe intentar dar servicio al equipo el ctrico m s all a lo descrito en las instrucciones de operaci n Todo otro servicio deber ser referido a personal de servicio calificado 9 El aparato el ctrico debe ser situado de tal manera que su posici n no interfiera su uso La colocaci n del aparato el ctrico sobre una cama sof alfombra or superficie similar puede bloquea la ventilaci n no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilaci n 10 El equipo el ctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u ostros aparatos incluyendo amplificadores que producen calor 11 El aparato el ctrico deber ser connectado a una fuente de poder s lo del tipo descrito en el instructivo de operaci n 0 como se indique en el aparato connected UTP device Setting the DIP switch to Pause Enable factory default allows the UTP port to Auto Negotiate to Symmetrical and Asymmetrical Pause Setting the DIP switch to Pause Disable forces the UTP port to Auto Negotiate only to No Pause Link Prop Link Isolate DIP Switch This DIP switch has no affect if the FlexPoint Gx is in F O AN mode Setting this DIP switch to Link Prop allows the link state to propagate from the UTP port to the F O port and allows the link state to propagate from the F O port to the UTP port The loss of a receive link on the F O
15. two devices to negotiate Duplex and Pause modes with each other Setting this DIP switch to Auto Neg factory default enables the FlexPoint Gx s F O port to detect the Duplex and Pause modes of the connected F O device The TRADEMARKS USED IN THIS MANUAL Black Box and the Double Diamon logo are registered trademarks of BB Technologies Inc Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners FEDERAL COMMUNICATIONS COMMISSION AND CANADIAN DEPARTMENT OF COMMUNICATIONS RADIO FREQUENCY INTERFERENCE STATEMENTS This equipment generates uses and can radiate radio frequency en ergy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio communication It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in subpart J of Part 15 of FCC rules which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment Operation of this equipment in a residential area is likely to be cause interference in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference Changes or modifications not expressly approved by the party respon sible for compliance could void the user s authority to operate the equ
16. with the manufacturer s instructions may cause interference to radio communication It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in subpart J of Part 15 of FCC rules which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment Operation of this equipment in a residential area is likely to be cause interference in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference Changes or modifications not expressly approved by the party respon sible for compliance could void the user s authority to operate the equipment This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regu lation of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num irques de las classe A prescrites dans le R glement sur le brouillage radio lectrique publi par le minist re des Communications du Canada 2 This product should only be used with Black Box Supplied Power Unit WARNING Before inserting the Power Adapter verify that the power on the unit is appropriate for your AC line voltage source Mounting and Cable Attachment
17. y en sus instrucciones de operaci n deben ser respetadas 4 Todas las instrucciones de operaci n y uso deben ser seguidas 5 El aparato el ctrico no deber ser usado cerca del agua por ejemplo cerca de la tina de ba o lavabo s tano mojado o cerca e una alberca etc 6 El aparato el ctrico debe ser usado nicamente con carritos 0 pedelstales que sean recomendados por el fabricante 7 El aparato el ctrico debe ser montado a la pared o al techo s lo como sea recomendado por el fabricante 8 Servicio E usuario no debe intentar dar servicio al equipo el ctrico m s all a lo descrito en las instrucciones de operaci n Todo otro servicio deber ser referido a personal de servicio calificado 9 El aparato el ctrico debe ser situado de tal manera que su posici n no interfiera su uso La colocaci n del aparato el ctrico sobre una cama sof alfombra or superficie similar puede bloquea la ventilaci n no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilaci n 10 El equipo el ctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u ostros aparatos incluyendo amplificadores que producen calor 11 El aparato el ctrico deber ser connectado a una fuente de poder s lo del tipo descrito en el instructivo de operaci n o como se indique en el aparato FlexPoint Gx s UTP port then negotiates with the connecte
Download Pdf Manuals
Related Search
Related Contents
Retours d`expérience License Definitions and Rules Definitions and License MODE D`EMPLOI Kelly KDHD Controllers User Manual ドットLEDを使った電光掲示板 i. Tech Dynamic iSlider User's Manual 品番 SV-ME970 Copyright © All rights reserved.
Failed to retrieve file