1. ADAM 6541 10 100Base TX Ethernet to 100Base FX Multi Mode Fiber Optic Converter User Manual Copyright The documentation and the software included with this product are copy righted 2006 by Advantech Co Ltd All rights are reserved Advantech Co Ltd reserves the right to make improvements in the products described in this manual at any time without notice No part of this man ual may be reproduced copied translated or transmitted in any form or by any means without the prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reli able However Advantech Co Ltd assumes no responsibility for its use nor for any infringements of the rights of third parties which may result from its use Acknowledgements Intel and Pentium are trademarks of Intel Corporation Microsoft Windows and MS DOS are registered trademarks of Microsoft Corp All other product names or trademarks are properties of their respective owners This manual covers the following models ADAM 6541 ADAM 6541 ST Part No 2003654101 2nd Edition Printed in Taiwan March 2006 ADAM 6541 User Manual ii Product Warranty 2 years Advantech warrants to you the original purchaser that each of its prod ucts will be free from defects in materials and workmanship for two years from the date of purchase This warranty does not apply to any products which have been repaired or altered b
2. Figure A 1 RJ 45 Pin Assignment White Green 1 2 Green 3 White Orange 4 Blue 5 6 7 lt Pin 1 White Blue Orange 4 Pin 8 White Brown Figure A 2 EIA TIA 568B ADAM 6541 User Manual 14
3. Off Link to 10 Mbps network ADAM 6541 User Manual 6 2 2 Dimensions units mm SC type fiber optic connector ST type fiber optic connector Figure 2 1 ADAM 6541 Front Panel 70 00 70 00 Figure 2 2 ADAM 6541 Bottom 7 Chapter 2 2 3 Full Half Duplex Selection There are two modes of data transmissions full duplex and half duplex transmission The data can be transmitted in both directions on a single carrier at the same time when you select Full duplex mode But the data can only be transmitted in one direction on a single carrier at the same time when you select Half duplex mode You may select Full or half duplex mode according to your equipment requirements You can configure full or half duplex ADAM 6541 via JP1 located on the top left PCB JP1 Description Half Duplex 3 2 110 Full Duplex Default 3 O l ps 1 NOTE Fiber Transmission Distance 1 Half duplex 412 m 2 Full duplex 2 km ADAM 6541 User Manual 8 2 4 Connecting the Hardware Next we will explain how to find a proper location for your ADAM 6541 connect to the network hook up the power cable and connect to the ADAM 6541 Ethernet port 2 4 1 Choosing a Location Due to its versatility and innovative design the ADAM 6541 can be fixed to a panel mount e fixed to a DIN Rail Piggyback Stack Panel Mounting The ADAM 6541 can be attached to a wall using the
4. be required to correct the interference at his own expense Safety Precaution Static Electricity Follow these simple precautions to protect yourself from harm and the products from damage 1 To avoid electrical shock always disconnect the power from your PC chassis before you work on it Don t touch any components on the CPU card or other cards while the PC is on Disconnect power before making any configuration changes The sudden rush of power as you connect a jumper or install a card may damage sen sitive electronic components ADAM 6541 User Manual iv Technical Support and Assistance Step 1 Step 2 Visit the Advantech web site at www advantech com support where you can find the latest information about the product Contact your distributor sales representative or Advantech s cus tomer service center for technical support if you need additional assistance Please have the following information ready before you call Product name and serial number Description of your peripheral attachments Description of your software operating system version appli cation software etc A complete description of the problem The exact wording of any error messages ADAM 6541 User Manual vi Chapter RRR N BWR Chapter NN KRW 2 5 Appendix A Contents OVERVIOW eec Mu Sata 2 Introduction Features Specifications sss Ordering Informatio
5. damages It is suitable for any harsh operating environment ADAM 6541 User Manual 2 1 2 Features Compact size economizes space Direct plug and play Easy to mount on a DIN rail panel or piggyback Supports full half duplex flow control Supports MDI MDI X auto crossover Embedded switch controller supports auto negotiation Embedded memory buffer supports store and forward transmission Supports 10 30 Vpc voltage Supports operating temperature from 10 65 C 1 3 Specifications ADAM 6541 Ethernet to Multi Mode Fiber Optic Converter Standard IEEE 802 3 802 3u 802 3x LAN 10 100Base TX 100Base FX Transmission Distance Ethernet 100m Fiber 2 000m Transmission Speed Ethernet up to 100 Mbps Fiber 100 Mbps Interface Connectors 1 x RJ 45 1 x SC type fiber connector ADAM 6541 1 x ST type fiber connector ADAM 6541 ST LED Indicators Power Full Link 100BASE FX 100 10M Ethernet Power Connectors 2 pin removable screw terminal Power Consumption Max 3W Power Input Unregulated 10 30 Vic 3 Chapter 1 Dimensions W x H x D 70 x 112 x 27 mm Enclosure IP30 ABS PC with solid mounting kits Mounting Isolation Protection DIN 35 rail Wall Stack 1 500 Vrms Ethernet Port Surge Protection EFT Operating Temperature 3 000Vpc Power 10 65 C 14 149 Stack 10 60 C 14
6. included metal brackets Each bracket comes with four screws First attach the brackets to the bottom of the ADAM 6541 then screw each bracket to a wall Figure 2 3 Figure 2 3 Panel Mounting 9 Chapter 2 DIN rail Mounting You can mount the ADAM 6541 on a standard DIN rail First using two screws attach the metal plate to the DIN rail bracket Because the screw heads are beveled the tops of the screws will be flush with the metal plate Din rail Mounting Brackets Orientation of Metal Plates A more convenient way is to screw the metal plate with the DIN rail bracket assembly to the bottom of the server Next use the remaining screws to put the metal plate on the bottom of the ADAM 6541 Figure 2 4 Din Rail Mounting ADAM 6541 User Manual 10 Piggyback Stack ADAM 6541 can be stacked as seen in the figure below Figure 2 5 Figure2 5 Piggyback Stack 2 5 Network Connection 2 5 1 Connection to the devices The ADAM 6541 consists of one fiber and one RJ 45 port Each of the converter s twisted pair ports can be used to connect a station or other device Use a straight through twisted pair cable with RJ 45 con nectors on both ends The twisted pair cable extended from a twisted pair port is called a twisted pair segment that can be up to 100 meters long You can connect any RJ 45 MDI X station port on the switch to any device that uses a standard network interface such as a workstation or server 11 C
7. 140 Storage Temperature 20 80 C 4 176 Operating Humidity 20 95 non condensing Storage Humidity 0 95 non condensing MTBF Safety 550 000hrs UL 60950 1 CAN CSA C22 2 No 60950 EMC USA FCC Part 15 CISPR 22 EU EN55011 EN55022 Class A EN61000 3 2 3 EN55024 IEC61000 4 2 3 4 5 6 8 11 1 4 Ordering Information ADAM 6541 ADAM 6541 ST ADAM 6541 User Manual 10 100 Base TX Ethernet to 100 Base FX Multi Mode SC Type Fiber Optic Converter 10 100 Base TX Ethernet to 100 Base FX Multi Mode ST Type Fiber Optic Converter CHAPTER Installation In this chapter you will be given an overview of the ADAM 6541 hardware installation procedures Sections include LED Indicators Dimensions Full Half Duplex Connections Connecting the Hardware Network Connection Chapter 2 Installation 2 1 LED Indicators There are six network LEDs located on the top panel of the ADAM 6541 each with its own specific function Table 2 1 ADAM 6541 LED Definition Power Green On Power is on Green Off Power is off Full Link 100Base Green On Connected to network FX Orange Green Flashing Networking is active Orange Green Off Not connected to network Orange 100 10M Ethernet Green On Connected to network Green Flashing Networking is active Green Off Not connected to network Orange On Link to 100 Mbps network Orange
8. d without proof of the purchase date is not eligible for war ranty service 5 Write the RMA number visibly on the outside of the package and ship it prepaid to your dealer iii Declaration of Conformity CE This product has passed the CE test for environmental specifications when shielded cables are used for external wiring We recommend the use of shielded cables This kind of cable is available from Advantech Please contact your local supplier for ordering information CE This product has passed the CE test for environmental specifications Test conditions for passing included the equipment being operated within an industrial enclosure In order to protect the product from being damaged by ESD Electrostatic Discharge and EMI leakage we strongly recom mend the use of CE compliant industrial enclosure products FCC Class A Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environ ment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Opera tion of this equipment in a residential area is likely to cause harmful inter ference in which case the user will
9. hapter 2 2 5 2 Connection to other Hubs or Switch ADAM 6541 has an RJ 45 port that supports the connection to 10Mbps Ethernet or 100Mbps Fast Ethernet and half or full duplex operation ADAM 6541 can be connected to other hub or switch via a two pair straight through cable or crossover cable The connection can be made from ADAM 654T s ports to other Hub or Switch such as MDI X port or uplink MDI port ADAM 6541 supports auto crossover to easily and flexibly network users connections You can connect any RJ 45 MDI X station port on the switch to any device such as a switch or a bridge or router 2 5 3 Connection to fiber network Connecting to the fiber network segment with three bud fiber You can use fiber standards via 50 125 62 5 125 um Core Clad With fiber optic it transmits speed up to 100 Mbps and you can prevent noise inter ference from the system and transmission distance up to 2 km 2 5 4 Power Connection You should take the following steps to connect ADAM 6541 power 1 Connect the power cable to 2 pin connector 2 Connect power cable to power adapter Fiber TX RX Ethernet Vs GND I I H H 10 30 V Note Please attach a dust cover to the unused fiber port for protection ADAM 6541 User Manual 12 APPENDIX Pin Assignments amp Wiring Appendix A Pin Assignments amp Wiring It is suggested to adopt ELA TIA as the wiring of the RJ45
10. n Installation 2 e deeeeeeccossa cec seoseseesescesecesase O LED Indicators nere RD rd eere 6 Table 2 1 ADAM 6541 LED Definition 6 Dimensions units mm ts Figure 2 1 ADAM 6541 Front Panel 7 Figure 2 2 ADAM 6541 Bottom ee 7 Full Half Duplex Selection esses 8 Connecting the Hardware 2 4 1 Choosing a Location Figure 2 3 Figure 2 3 Panel Mounting 9 Figure 2 4 Din Rail Mounting eee 10 Figure 2 5 Figure2 5 Piggyback Stack 11 Network Connection 2 5 1 Connection to the devices 2 5 2 Connection to other Hubs or Switch ss 12 2 5 3 Connection to fiber network sseesee 12 2 5 4 Power Connection cccccccsccssecssesseeseecseceeeecseeseeeeseens 12 Pin Assignments amp Wiring 14 Figure A 1 RJ 45 Pin Assignment sees 14 Figure A 2 EIA TIA 568B sessseeee 14 vii Table of Contents ADAM 6541 User Manual viii CHAPTER Overview This chapter gives an overview of ADAM 6541 modules Sections include Introduction Features Specifications Ordering Information Chapter 1 Overview 1 1 Introduction The ADAM 6541 1s an industrial grade converter designed to convert Ethernet network 10 100Base TX to fiber network 100Base FX It transparen
11. tly converts Ethernet signals into optic signals The advantages of Fiber optic are wide bandwidth anti EMI and suitable for long dis tance transmission Therefore ADAM 6541 is an ideal solution for fiber to building application in central offices or local sites The ADAM 6541 can be mounted in the following three ways DIN Rail panel piggyback mounting 10 30 Vp operating voltages are also sup plied over the terminal block In addition the operating temperature ranges from 10 65 C The above functions make the ADAM 6541 a stable and reliable industrial grade converter High Speed Transmissions The ADAM 6541 supports MDI MDI X of auto detection You will not need to crossover A switch controller that can automatically sense trans mission speed 10 100 Mbps will be included Both Ethernet and fiber ports have memory buffers that support store and forward mechanism it assures proper data transmission Flexible Mounting The ADAM 6541 is extremely compact and can be mounted in three dif ferent ways DIN rail panel and piggyback mounting Easy Troubleshooting The ADAM 6541 provides three LED indicators Power Full Link 10 100Mbps which easily let you troubleshoot Robust Enough for Industrial Environments The ADAM 6541 can normally work from 10 C to 65 C and accepts wide unregulated voltage range from 10 30 VDC Besides it also pro vides 3 000 VDC surge protection EFT to protect it from over voltage
12. y persons other than repair personnel authorized by Advantech or which have been subject to misuse abuse accident or improper instal lation Advantech assumes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous test ing most of our customers never need to use our repair service If an Advantech product 1s defective it will be repaired or replaced at no charge during the warranty period For out of warranty repairs you will be billed according to the cost of replacement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem encountered For example CPU speed Advantech products used other hardware and software used etc Note anything abnormal and list any onscreen messages you get when the problem occurs 2 Call your dealer and describe the problem Please have your man ual product and any helpful information readily available 3 Ifyour product is diagnosed as defective obtain an RMA return merchandize authorization number from your dealer This allows us to process your return more quickly 4 Carefully pack the defective product a fully completed Repair and Replacement Order Card and a photocopy proof of purchase date such as your sales receipt in a shippable container A product returne

Download Pdf Manuals

image

Related Search

Related Contents

User Guide - Ubee Interactive  Reichert Model 13104190/13104230 Reichert Typ13104190  DSC mini 取扱説明書ダウンロード  Samsung 32" Curved TV J6300 Series 6  TVD-5110-3 Dome Camera Pocket Guide  Enregistreur numérique Manuel d`utilisation PC Cher client q Guide  ASRock VisionX Series Quick Start Manual  FICHE DE POSTE agent de maitrise propreté  性能で、スタイルで選べる、ダイナブックシリーズ  Actes de l`Université d`été de la solidarité internationale Nantes 2006  