Home

Draper Silhouette/Series E

image

Contents

1. White Blue Common Red to screen directional roH Red 110 Black 220 Up Brown to screen directional 4 Black 110 Brown 220 Down Yellow to 110 220V AC Hot E vp SE Green Yellow 1 Black to 110 220V AC Hot aa A Motor Ground Green Yellow Ground 7 oles ll ae re Dashed wiring by electrician PTER Low voltage wiring by others Meee IEA To Eye Port for IR Eye RF Receiver or LED l O i 110 220V Wall Switch For more than one of E Ley _ _ Line these a splitter is required Location of key EE E T lt operated on of ia COM While ir iteterecteteryetess switch if furnished UP Red SET eCee CeCe eR eT ee ee ee e eee Control Aux Port for connecting additional LVC III Switches modules up to six total can be linked 24v DC connect from Aux to Eye External Two Way Serial Communication RS232 with MC1 Internal Screen Wiring White Common t White Common to screen amp 110 120V AC Neutral 1 Red to Screen directional r p Brown to Screen directional r H Black Down Program LED Black Hot to 110 120V AC Green Yellow Gnd Green Yellow Ground i eS Low Voltage Wiring by others l en Ean AC Wiring by electrician E
2. amp PLAY Provided with handheld IR remote control transmitter and 10 3m cord No wiring necessary except to connect to RS232 Screen is equipped with a handheld remote or 3 position operating switch see below Three positions up off down permit operation to be stopped at any point Factory adjusted limit switches automatically stop screen when fully down or fully up Limit Adjustments Standard Motor Please Note Screen limits are factory set for optimum performance of the screen A procedure is outlined below for minor tweaks but any ad justment of these limits may negatively affect the flatness of the screen surface and could also void the warranty Please check with Draper prior to resetting screen limits A CAUTION Always be prepared to shut screen off manually when new adjustment is being tested Screen may be severely damaged if viewing surface is allowed to run too far up or too far down A CAUTION Be sure all switches are in off position before adjusting limit switches The motor limit screws are normally located on the audience left of screen roller www draperinc com DRADER 765 987 7999 Silhouette Series E amp V by Draper DOWN LIMIT ADJUSTMENT To Reduce Screen Drop Raise screen surface about 1 above desired setting and turn off Turn the DOWN limit screw White or I clockwise three screw turns 12 roller revolution Test by running screen down and repeat steps 1 and 2 until desired po
3. Clips to allow case lip to be engaged over the lip of the Z Clips Engage the lip on back of screen case with lip of Z Clip and gently pull down to fully engage case to brackets Mise 411 S Pearl St Spiceland IN 47385 USA I 765 987 7999 www draperinc com I fax 765 987 7142 Copyright 2014 Draper Inc Form SilhouetteE amp V_Inst14 Printed in U S A US Patent Nos 5 296 964 6 111 694 Lip on back of case gt Silhouette fully engaged on Z Clip Z Clip wall mounting bracket supplied with Silhouette Ceiling Suspended Mounting Locate two offset ceiling brackets supplied and slide these into the chan nel on top of screen case by aligning the chamfered edges of each bracket parallel to the channel length Allow bracket to drop against bottom of channel and then rotate bracket counter clockwise Slide one bracket to each end of screen case until it stops against end cap of case Tighten two set screws to lock bracket in place Make sure that the flange of the ceiling bracket that has four holes is extended beyond the end caps of the case Repeat above procedure for second ceiling bracket making sure to slide it towards opposite end of case Ceiling bracket in channel of case i To mount against ceiling hold screen case against ceiling and mark mount ing hole locations Each bracket has two holes towards the front edge and two holes towards the back edge Installer must use at least two fas
4. Installer must insure fasteners not included are of adequate strength and suitable for chosen mounting surface Attach hanging bracket to wall bracket as shown Attach 1 Z Clip and 1 Support Plate supplied with screen to hanging bracket as shown Engage the lip on back of screen case with lip of Z Clip and gently pull down to fully engage case to brackets Install hook bracket as shown making sure the two tabs of this bracket hook over the case extrusion Install 10 24 hex head screw through hook bracket hanging bracket and support plate as shown Wall CB 4 20 x 134 Z Keg Bracket Flat Washer 14 20 Nylock Nut H 10 24 x Vo Hex Head Screw s so Support 10 24 x 7 e Plate Phillips Pan Head Screw Nylock Nut Removing Case Fascia Caution When removing or reattaching fascia do not handle fascia by unpainted ends Case fascia is removable to access roller assembly To remove fascia depress outward the spring lip located inside lower front corner of screen case and pull lower corner of fascia outward Repeat this at right end of case Support fascia from center and rotate lower front edge upward approximately 40 to disengage the Roll Lok hinge at the top front of screen case Fascia can now be completely removed from case To install fascia generally reverse instructions above making sure the Roll Lok hinge is completely engaged before rotating fascia down to
5. Installation Operating Instructions Silhouette Series E amp V Electric Projection Screen by Draper Z Caution Read instructions through completely before proceeding keep them for future reference Follow instructions carefully Installation contrary to instructions invalidates warranty Care in mounting and correct oper ation will mean long and satisfactory service from your Draper screen Screen should be accessible for complete removal should fabric become damaged or should other service be required Screen should be installed level using a carpenter s level Nothing should be fastened to screen dowel or viewing surface Operating switch es packed separately in screen carton Do not discard with packing material Screen operates on 110 120V 60 hz 1 1 amp current draw NOTE Screen has been thoroughly inspected and tested at factory and found to be operating properly prior to shipment These instructions are meant as a guide only They do not imply any responsibility on the part of Draper Inc for improper installation or faulty workmanship at the jobsite Installation Your Draper screen can be mounted on a wall or suspended from the ceiling or mounted on 6 or 10 14 extension brackets Extension brackets must be ordered separately from Draper With each method of installation the case must be mounted level and with the flat back parallel to the wall To reduce the risk of personal injury us
6. d gt Black i l Dashed wiring l i i by electrician 1 i Red Blue he pe ee a I I I fi 1 2 l Location of ke I ria y 1 Operated on off i Black i L switch if furnished i i Red Blue f To 110 120V Line Black _ Single gang box by others Min 4 x 2 s x 17s deep 3 shown More or less equally feasible 47 Location of key 1 l operated on off L switch if furnished I i 1 To 110 120V Line ILT Switch to Motor Dry Contacts or Data Cable connection Please Note This Splitter Jack is located inside the junction box of your screen Data Cables to switches or to additional motors can be plugged into any of the three open jacks If this is a Case First Screen Later installation plug the motor cable into the jack indicated in the drawing Back of wall switch Motor Data Cable plugged in here Please Note 5V DC must be connected to be able to set limits using the wall switch Please Note Although both Dry Contact and Data Cable connections are shown you should only use one connection type per motor Page 4 of 5 7 8 holes for supply wires located on back and top 21 2 from left end of case Wiring Diagrams 110 120V Motor and Quiet Motor with Built in Low Voltage Controller Single Low Voltage Control Internal Screen Wiring r 4 o White Neutral paas A ae Black E Dashed wiring by electric
7. e 2 of 5 of the building installation All operating switches should be off before power is connected Plug in power cord option available on units with built in low voltage controller For Reconfiguration Conversion of Non detachable Power Cord to Field Wiring for Models SLE 28 SLE 30 SLV 28 and SLV 30 Only Disconnect cord plug from outlet Remove junction box cover Disconnect wire nut connections from black white and green wires Remove power cord and strain relief Connect the black from motor to hot supply wire Connect white wire from motor to neutral supply wire Connect green yellow ground to ground supply wire Replace junction box cover Operation Before operating screen remove any shipping brackets or tape securing fab ric and dowel to the roller If viewing surface hangs out of case 8 or 9 tape has probably been broken by rough handling in shipment allowing surface to unwrap one turn off the roller Manually wrap fabric back around the roller without turning the roller itself When screen is first operated be cautious Cycle unit down and up several times to confirm satisfactory operation 110 120V SINGLE STATION CONTROL 3 position UP OFF DOWN switch permits operation to be stopped at any point Factory adjusted limit switches automatically stop screen when fully down or fully up 110 120V MULTIPLE STATION CONTROL Switches are similar in ap pearance to 110 120V Single Station C
8. e only the hardware which comes with the screen or is specified in these instructions The screen or wall extension brackets should be mounted into studs or blocking in the wall ceiling or in drywall minimum thickness 2 with speci fied anchors For any other type of installation follow all local building and safety codes Steel studs concrete or cinder block walls and all other types of non wood frame construction require the use of special screws or anchors The selection of appropriate mounting hardware should be made by a qualified professional installer When locating viewing surface and checking clearance for screen s operation remember surface is centered in case Take care to install wall ceiling electrical box and conduit so they will be fully concealed by the screen case after installation Handle case carefully to avoid scratching Regardless of mounting method screen should be positively and securely supported so that vibration or even abusive pulling on the viewing surface will not cause case to work loose or fall Installer must insure that fasteners used are of adequate strength and suitable for the mounting surface chosen Wall Mounting Mount two three or four aluminum brackets provided Z Clips on the wall at desired height using appropriate fasteners Verify that they are in line and level to fully engage with the mounting lip on back of screen case 1 s of free space is required above the Z
9. ian Data Cable i 1 I 1 i i RJ 9 i connector l I i 1 i i l l l Wall Switch RF or IR Receiver or integrated 1 1 I 1 control system l To 110 120V Line r 7 Green Yellow Ground To 110 120V Line r Multiple Low Voltage Controls Internal Screen Wiring gt White Neutral l psa 1 o Green Yellow Ground L Dashed wiring by electrician Data Cables RJ 9 connectors Wall Switches RF or IR Receivers or integrated 1 i 1 1 l l I if I 1 j l 1 1 1 i 1 i control systems Wiring Diagrams Plug amp Play 110 120V Motor with Built in Low Voltage Controller Single Low Voltage Control ii White Neutral ss Black Green Ground Wall Switch RF or IR 110 120V Feceiver Plug or integrated control system www draperinc com DARRER 765 987 7999 Internal Screen Wiring Data Cable 110 120V Plug Multiple Low Voltage Controls Internal Screen Wiring o White Neutral o Black o Green Ground Data Cables Wall Switches RF or IR Receivers or integrated control systems Silhouette Series E amp V by Draper Page 5 of 5 External Low Voltage amp Wireless Control Internal Screen Wiring White or Blue Common to screen amp 110 220V AC Neutral
10. oR RS232 Data FROM Control System i ee a To oo oe R9292 Data 1O onol stem a 7 110 120V A e Signal Groun anual Switch Common 4 ___ Line See separate Serial Cc Manual Switch Down ere n nTn seg eee Loy ommunication RS232 W CF __ Lt Manual Switch Up otto aoe scatenati key C tion RS232 Manual Switch Up m Li k Instruction sheet for A operated ori otf enabling RS232 with Eye Port for IR Eye For RF Receiver or LED lt switch if furnished Wall Switch a Splitter and a Power Supply the MC1 is required Plug RF Receiver or LED Wall Control Switch and Power Supply into splitter then Switches run cable from Splitter to MC1 Eye Port 24v DC Wiring Diagrams for Optional Built in Video Interface Control Built in Video Interface Control Junction box at left end of screen Internal screen wiring N oO White Neutral 115 VAC supply G o Black Hot oO Green Ground Trigger signal 7 o VIC115 115 VAC white cord amp plug l VIC12 12 VDC brown amp orange leads L__ Dashed wiring by electrician Built in Low Voltage Control Junction box at left end of screen Internal screen wiring N o White Neutral 110v AC supply 4 o Black Hot oO Green Ground Dashed wiring by electrician www draperinc com RARER 765 987 7999
11. ontrol Screen stops when switch is released and may be restarted in either direction Factory adjusted limit switches stop screen automatically when fully down or fully up 24V MULTIPLE STATION CONTROL Three button UP STOP DOWN switches stop at any point desired operate in any sequence Factory adjusted limit switches automatically stop screen when fully down or fully up 110 120V amp 12V VIDEO INTERFACE CONTROL Allows screen to be con trolled by a trigger signal when the signal comes on the screen descends automatically Two versions Model VIC115 integrates screen operation with a DRAPER video projector lift or a video projector or tuner with a 110 120V switch outlet Model VIC12 interfaces with a 12V switch outlet Both available with an override switch VIC OS permitting independent operation VIC OS not available with factory installed VIC115 amp VIC12 KEY OPERATED SWITCHING Two kinds of key operated switches are optionally available with this unit The key operated power supply switch controls power to the screen and switches When it is off the switches will not operate screen Key may be removed from the switch in either on or off position A three position key switch permits the screen to be operated directly by key In this case the screen s operator must always have a key RS232 ETHERNET Serial communication and network communication optionally available with wall switches RF or IR remote PLUG
12. rse the operation of the UP and DOWN switches Move slider switch into center position Wait a couple of seconds Please Note If you move the slider switch from down to up in one mo tion it sets the two limits in the same position Set the slide switch to the higher position Move the viewing surface to the desired upper limit by pressing and holding the UP button on the wall switch Return the slide switch to the center position to return to normal operation To set the viewing surface to an alternate format position move the viewing surface to the desired position and press the STOP button Press and hold the STOP button for at least three seconds to record the position Caution Do not remove the roller assembly from the case unless necessary for repairs If the roller assembly is removed be sure motor is fully re seated in the bracket and re secure it carefully with the mo tor retaining spring see diagram at right Page 3 of 5 UP LIMIT ADJUSTMENT Screen is Running Too Far Up Lower screen surface about 1 below desired setting and turn off Turn the UP limit screw Yellow or II clockwise three screw turns 2 roller revolution Test by running screen up Repeat steps 1 through 3 until desired position is reached Screen Needs to Run Up More Run screen down about 1 and turn off With the up switch on turn the UP limit screw Yellow or II limit screw counterclockwise three turns of
13. screw roller revolution Repeat steps 1 and 2 until desired position is reached A CAUTION Do NOT allow the dowel to wrap up over the roller when the screen is running up This could damage the screen 00 OO To Motor OO O OO with UD C Built In P o o BY Low Voltage n m Please Note 5V DC must be o connected to be able to set g limits using the wall switch POSITION FUNCTION 7a DOWN Set LOWER limit UP Set UPPER limit To Motor Slide O a with CENTER Normal Operation Switch Built In Low Voltage Back View Please Note Pressing and releasing the UP button on the switch will move the screen to its upper limit Pressing and releasing the DOWN button will move the screen to its lower limit While the motor is in motion pressing the STOP button for less than two seconds will stop the viewing surface at its present position Once the motor is stopped pressing the STOP button will move the view ing surface to its alternate format position Pressing and holding the STOP button when the motor is at rest or in mo tion for at least three seconds will record a new alternate format position Tab Tension Adjustment Procedure for Silhouette Series V Determine which side requires adjustment Secure dowel with one hand Caution Do not touch or bend surface Using Phillips head screwdriver depress spring loaded adjustment screw see drawing and slowly turn clockwi
14. se to tighten tension or counterclockwise to loosen tension The screw adjusts in 14 turn increments Adjust only one increment 14 turn If problem is not corrected leave screen in position for 24 hours to allow surface material to stretch into position If problem still is not corrected repeat steps 2 and 3 Tensioning Cable Dowel a Adjustment Screw i www draperinc com DRADER 765 987 7999 Silhouette Series E amp V by Draper Case Dimensions Silhouette D Series E 6 Series V Varies Series E Viewing Surface Shown Series V with Tab Tensioning also available At left Series V slat bar is depicted inside case Series E has a typical round bottom dowel For all Silhouettes the dowel is concealed inside the case Viewing Surface Wiring Diagrams Please Note Do not wire motors in parallel Wiring Diagrams 110 120V Motor and Quiet Motor Single Station Control Multiple Station Control Internal Screen Wiring Internal Screen Wiring o White Common r f 4 gt White Common fSscees e Black Down a l Black Down E r 1 Red Up r J 2 Red Up i i r gt Green Yellow Ground T piem Green Yellow Ground ll 1 ESN I 1 1 Dashed wiring i f map a we E by electrician ibaa anu 2 ape I ol I oy Control Single gang box by others Blue i I switch Min 4 x 21 8 x 17 8 deep i 1 i Blue I i i Re
15. sition is reached To Increase Screen Drop Run screen to the down limit With the down switch on turn the DOWN limit screw White or I limit screw counterclockwise three screw turns roller revolution to increase drop Test by running screen up about 1 and back down to new down limit Repeat steps 2 and 3 until desired position is reached Limit Adjustments Built in Low Voltage Motors Please Note Screen limits are factory set for optimum performance of the screen Any adjustment of these limits could void the warranty Please check with Draper prior to resetting screen limits A CAUTION Always be prepared to shut screen off manually when new adjustment is being tested Screen may be severely damaged if viewing surface is allowed to run too far up or too far down A CAUTION Be sure all switches are in off position before adjusting limit switches Height adjustments are made from wall switch Connect the ILT switch to the motor via the terminal blocks or via the modular port using four conductor modular cable When using modular cable the cable connectors MUST NOT be crimped in reverse as with standard telephone cable Set the slide switch to the lower position Press and hold the DOWN button on the switch to move the viewing surface to the desired lower limit If the screen moves in the opposite direction release the DOWN button and press and hold down the STOP button for four seconds This will reve
16. teners per bracket with one fastener in one of the two holes closest to back edge of bracket and one fastener in one of the two hole closest to front edge of bracket Installer must insure that fasteners are of adequate strength and suit able for the mounting surface chosen N AAN Sceiting bracket Mounting fasteners supplied by others 2 per bracket right end of Silhouette case front of Silhouette case To mount suspended from ceiling the brackets need to be installed on screen case as noted on page 1 Use S Hooks through the holes in the brackets to attach to ceiling Select the set of holes that allows the screen to hang in a vertical position The installer is to provide the S Hooks and the materials and fasteners to attach the S Hooks to the ceiling Installer must insure that the fasteners and suspension material is of adequate strength and suitable for the mounting surface chosen If you encounter any difficulties installing or servicing your screen call your dealer or Draper Inc Spiceland Indiana 765 987 7999 or fax 765 987 7142 Silhouette Series E amp V by Draper Extension Wall Brackets 6 or 10 14 Extension Wall Brackets are needed to mount Silhouette extended from wall Wall Brackets are not supplied with screen and must be ordered separately Specify Silhouette Extension Wall Brackets Mount the Wall Brackets to the wall making sure they are level and verti cally plumb
17. wards the closed position Depress spring clips outward push lower corners of fascia inward until lips of spring clips hook behind fascia Please Note Be sure the clips are completely up against the ends of the fascia Electrical Connections Screen operates on 110 120V 60 Hz 1 1 amp current draw Duty Cycle ON 28 seconds OFF 4 minutes Junction box is located at left end of screen It is accessible through front of screen case after fascia is removed see instructions above for removing fascia Electrical supply wires can enter through the back or top of case For top entry remove plug from top conduit hole and snap plug into hole on back side of case Junction box contains red black and white pigtail leads and green internal ground wire per wiring diagram attached If optional low voltage control or video interface control is specified please refer to wiring diagrams on pages 4 5 Wall or ceiling electrical box should be installed so as to be fully concealed by screen case after installation Screen is shipped with internal wiring complete and control switch es fully boxed Wire to connect screen to switch es and switch es to power supply should be furnished by installer Please Note Screen must be installed in accordance with the requirements of the Local Building Codes the Cana dian Electrical Code CEC CAN CSA C22 1 and the National Electric Code NEC NFPA 70 An appropriate disconnect device shall be provided as part Pag

Download Pdf Manuals

image

Related Search

Related Contents

cruising mount kit - HARLEY  Weber 55791 Owner's Manual  仕 様 - 日立の家電品  Hand-Gabelhochhubwagen Electric Stacker-Push Travel  HandyTone 286 User Manual Grandstream Networks  取扱説明書 - ワイズギア  ACP-EP Memory EPUSBFP/256-2.0 User's Manual    Steamer SO 2508PS Dampfgargerät - Migros  Technical Specification  