Home
Oregon Scientific BAR208S weather station
Contents
1. OreGon Advanced Weather Station with Atomic Time Model BAR208HGA USER MANUAL OVERVIEW 1 Remote sensor reception indicator 2 Moon phase reading 3 Weather forecast 4 Indoor temperature with temperature trend 5 Clock signal reception indicator 6 MODE Change settings display 7 A F Increase decrease settings activate deacti vate clock reception signal 8 Outdoor temperature with temperature trend 9 Outdoor humidity with humidity trend 10 Weather warning message 11 Indoor humidity with humidity trend 12 Time zone 13 Clock with weekday 14 MEM View current temperature humidity 15 LIGHT Activate backlight for 5 seconds 16 Ice alert LED indicator maximum and minimum 1 C F Select temperature unit 2 RESET Reset unit to default settings LCD display LED status indicator Wall mount hole RESET hole CHANNEL switch Battery compartment D Ji ek SS GETTING STARTED 1 Remove the battery compartment 2 Insert the batteries matching the polarities see FIG 2 3 Press RESET after each battery change lt B LOCATION Clock alarm and Indoor temperature area MEANING Main unit batteries low Outdoor temperature area Sensor batteries low REMOTE SENSOR The main unit can collect data from up to 3 s
2. by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help The following information is not to be used as contact for support or sales Please call our customer service number listed on our website at www oregonscientific com or on the warranty card for this product for all inquiries instead We Name Oregon Scientific Inc Address 19861 SW 95 Ave Tualatin Oregon 97062 USA Telephone No 1 800 853 8883 declare that the product Product No BAR208HGA Product Name Advanced Weather Station with Atomic Time Manufacturer IDT Technology Limited Address Block C 9 F Kaiser Estate Phase 1 41 Man Yue St Hung Hom Kowloon Hong Kong is in conformity with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may Cause undesired operation P N O86LOOXXXX XXX
3. ensors To set up the sensor 1 Open the battery compartment with a small Philips screwdriver and insert batteries matching the polarity 2 Select a channel then press RESET Close the battery door 4 Place the sensor within 30 m 98 ft of the main unit using the table stand or wall mount w TIP Ideal placements for the sensor would be in any location on the exterior of the home at a height of not more than 5 ft and which can shield it from direct sunlight or wet conditions for an accurate reading i i NOTE Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing To search for a sensor Press and hold A MODE The sensor reception icon in the remote sensor area shows the status ICON DESCRIPTION OUT OUT gt Main unit is searching for sensor s ay a A channel has been found OUT The sensor cannot be found TIP The transmission range may vary depending on many factors You may need to experiment with various locations to get the best results CLOCK This product is designed to synchronize its clock automatically with WWVB 60 signal within 3200km 2000 miles of Fort Collins Colorado To enable disable signal reception Press and hold to enable or W to disable signal reception NOTE Reception takes 2 10 minutes If the signal is weak it can take up to 24 hours to get a valid signal If signal reception is unsuccessful place your
4. in the US and would like to contact our Customer Care department directly please visit www2 oregonscientific com service support OR Call 1 800 853 8883 For international inquiries please visit www2 oregonscientific com about international FCC STATEMENT This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection againstharmful interference ina residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference
5. n between sensors Press and hold W MEM to display each sensor s data for 3 seconds To end press To toggle between current minimum and maximum records for the selected sensor Press MEM repeatedly To clear the records Press and hold MEM If the channel 1 sensor falls between 3 C to 2 C 37 F to 28 F LED indicator will flash and will stop flashing once the temperature is out of this range The temperature humidity and pressure trend icons are based on recent sensor readings MOON PHASE n moon phase mode press Aor V toscan through the years 2001 to 2099 NOTE Star icons around the moon phase will be displayed from 6 o clock in the evening to 6 o clock the next morning BACKLIGHT Press LIGHT to activate backlight for 5 seconds RESET Press RESET to return to the default settings PRECAUTIONS Do not subject the unit to excessive force shock dust temperature or humidity Do not cover the ventilation holes with any items such as newspapers curtains etc Do not immerse the unit in water If you spill liquid over it dry it immediately with a soft lint free cloth Do not clean the unit with abrasive or corrosive materials Do not tamper with the unit s internal components This invalidates the warranty Only use fresh batteries Do not mix new and old batteries Images shown in this manual may differ from the actual display When disposing of this product ensure it i
6. s collected separately for special treatment Placement of this product on certain types of wood may result in damage to its finish for which Oregon Scientific will not be responsible Consult the furniture manufacturer s care instructions for information The contents of this manual may not be reproduced without the permission of the manufacturer Do not dispose old batteries as unsorted municipal waste Collection of such waste separately for special treatment is necessary Please note that some units are equipped with a battery safety strip Remove the strip from the battery compartment before first use NOTE The technical specifications for this product and the contents of the user manual are subject to change without notice SPECIFICATIONS TYPE DESCRIPTION MAIN UNIT LxWxH 182 5 x 94 x 51 mm 7 19 x 3 70 x 2 01 in Weight 241 g 8 5 oz without battery Temperature range 5 C to 50 C 23 F to 122 F Resolution 0 1 C 0 2 F Signal frequency 433 MHz Humidity range 25 95 Humidity resolution 1 Power 3 x UM 3 AA 1 5 V batteries REMOTE UNIT THGR122NR LxWxH 92 x 60 x 20 mm 3 62 x 2 36 x 0 79 in Weight 63 g 2 22 ounces without battery Transmission range 30 m 98 ft unobstructed Temperature range 20 C to 60 C 4 F to 140 F Power 2 x UM 4 AAA 1 5 V batteries ABOUT OREGON SCIENTIFIC Visit our website www oregonscientific com to learn more about Oregon Scientific products If you re
7. unit next to a window press and hold A to force another signal search Clock signal reception indicator STRONG SIGNAL WEAK SIGNALNO SIGNAL To set the clock manually disable the signal reception first 1 Press and hold MODE 2 Press or W to change the settings 3 Press MODE to confirm 4 The settings order is time zone 12 24 hr format hour minute year calendar mode day month month day month day and language Select the time zone P Pacific E Eastern C Central or M Mountain NOTE The language options are English E German D French F Italian 1 and Spanish S To select display mode Press MODE to choose between clock with seconds weekday calendar moon phase WEATHER FORECAST This product forecasts the next 12 to 24 hours of weather within a 30 50 km 19 31 mile radius US with a 75 accuracy yA Da 4 ao Sunny oo Partially Cloudy Con Cloudy n Rainy Snowy WEATHER WARNING MESSAGE The weather warning messages provide indications of probable circumstances that may arise based on the weather station s calculations The meanings for the warnings are illustrated below Warning Meaning HEAT Risk of high temperatures Risk of fast wind speeds STORM Risk of a storm Risk of foggy conditions Jk FROST Risk of icy conditions DYE z Z oO TEMPERATURE AND HUMIDITY To toggle temperature unit Press C F To auto sca