World Marketing of America LP Forced Air

image

Contents

1. HEAT PROPANE CONSTRUCTION HEATER USER S MANUAL AND OPERATING INSTRUCTIONS DURAHEAT GFA40 40 000 BTU HR FORCED AIR MODELS GFA50A 30 000 50 000 BTU HR FORCED AIR GFA60A 30 000 60 000 BTU HR FORCED AIR GFA100A 70 000 100 000 BTU HR FORCED AIR GFA125A 70 000 125 000 BTU HR FORCED AIR GFA150A 120 000 150 000 BTU HR FORCED AIR CSA 2 14a 2007 ANSI Z83 7a 2007 A GENERAL HAZARD WARNING FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER CAN RESULT IN DEATH SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM THE HAZARDS OF FIRE EXPLOSION BURN ASPHYXIATION CARBON MONOXIDE POISONING AND OR ELECTRICAL SHOCK ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTION MANUAL LABELS ETCETERA CONTACT THE MANUFACTURER RETAIN THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE World Marketing of America Inc PO Box 192 12256 William Penn Hwy Mill Creek PA 17060 0192 Tel 1 800 776 9425 www worldmkting com Printed in China Rev 1 10 TABLE OF CONTENTS Introduction amp Specifications o oo e 3 General Safety AMSUMCHOMS AE GE ES A Fu 4 Product Features ss sue did a GO fedeo angea gon ao erase aa 4 Unpacking zu 4 hearth ne Hh eee DEE 5 e S
2. Input Rating AAWARNING NOT FOR USE WITH DUCT WORK 40 000 BTU hr SPECIFICATIONS 30 000 BTU hr 50 000 BTU hr 70 000 BTU hr 100 000 BTU hr 70 000 BTU hr 125 000 BTU hr 120 000 BTU hr 150 000 BTU hr Type of Gas Propane Propane Propane Propane Propane Gas Supply Pressure to Regulator Maximum Cylinder Pressure Cylinder Pressure Cylinder Pressure Cylinder Pressure Cylinder Pressure Minimum for purpose of Input Adiustment 5psig 5psig 5psig Manifold Pressure 11 W C 11 W C 11 W C Gas Consumption Electrical Input 1 4lbs hr 2 3lbs hr 120V 60Hz 10 120V 60Hz 10 3 3lbs hr 5 8lbs hr 120V 60Hz 10 Amperage Load 0 65amps 3570rpm 3300rpm 0 7amps 3580rpm 3300rpm 0 7amps 3580rpm 3300rpm Ignition Piezo Manual Spark Continuous Spark Continuous Spark Continuous Spark Continuous Spark Continuous Spark Spark Gap 0 16 Amm 0 16 Amm 0 16 Amm 0 16 Amm 0 16 Amm 0 11 2 8mm Size LXWxH 19 3 x8 3 x15 2 490x211x386 mm 19 3 x8 3 x15 2 490x211x386 mm 19 3 x8 3 x15 2 490x211x386 mm 25 6 x12 7 x15 6 650x323x396 mm 25 6 x11 8 x16 1 650x300x409 mm 25 6 x12 7 x15 6 650x323x396 mm 25 6 x11 8 x16 1 650x300x409 mm 25 6 x11 8 x16 1 650x300x409 mm 13 7lbs 14lbs 6 2kg 6 35kg 21 5lbs 21lbs 20 8lbs 21 51bs 211bs 20 8lbs
3. Weight ki 9 75kg 9 5kg 9 4kg 9 75kg 9 5kg 9 Akg 14 3lbs 6 48kg 14 3165 6 48kg 21 2lbs 9 6kg GENERAL SAFETY INSTRUCTION Accidents are always tragic especially because so many of them could have been prevented with little care and judgment There are some basic good practices we hope you will follow for safe use of your heater IMPORTANT SAFETY INSTRUCTION Children should be carefully supervised when they in the area Always maintain proper clearance from combustible materials Minimum clearance from combustibles Side 24 61cm Top 36 91cm Front 72 1 8M Floor combustible Not for use on finished floors Heater must be placed on level and stable surface Never place anything including clothes or other flammable items on the heater The appliance area shall be kept clear and free from combustible materials gasoline and other flammable vapours and liquids Do not modify or operate a heater which has been modified Adequate clearance for accessibility and for combustion amp ventilation air supply must be maintained at all times when the heater is operating Service and repair should be done by a qualified service person The heater should be inspected before each use and at least annually by a qualified person More frequent cleaning may be required as necessary Do not service while hot or operating Never connect heater to an unregulated gas supply The heater is shipped fro
4. When burner is lit turn gas valve knob counterclockwise to desired setting All models except 40 series Oo 00 Y Y SHUTDOWN INSTRUCTIONS AA WARNING Motor and fan must be running before lighting during operation and at shutdown in order to prevent a flame out condition which could result in personal injury or property damage Turn gas valve knob clockwise to OFF position Turn gas supply OFF by turning Propane tank valve clockwise to close Disconnect the power cord once the heater has cooled to ambient temperature TEST FIRING HEATER Test fire your construction heater following the lighting instructions applicable to the gas control system employed Leak test all gas connections with soap solution Soap bubbles indicate gas leakage DO NOT use a match or flame to test for gas leaks STORAGE Never store a Propane gas tank inside a building or in the vicinity of any gas or oil burning appliance When the Propane tank is not disconnected from the construction heater the gas tank and heater must be stored out doors in a well ventilated area out of the reach of children If for any reason the heater is to be stored indoors the tank must be disconnected and stored outdoors in a well ventilated area out of reach of children in accor dance with the standard for the the Storage and Handling of Liquefied Petroleum Gases ANSI NFPA 58 and CSA B149 1 Natural Gas and Propane Installation Code The plastic tank
5. valve plug supplied with your tank must be tightly installed when the tank is disconnected from the heater MAINTENANCE INSTRUCTIONS 1 Turn unit off allow heater to fully cool and disconnect propane hose before performing any Maintenance functions Unplug the unit from the 120V receptacle 2 Keep unit clean and keep the inside of the torpedo housing debris free 3 Have unit checked by a qualified technician at least once a year preferably prior to the heating season TROUBLESHOOTING PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION 1 Fan does not turn when 1 No electric power to heater Check current to electric outlet If voltage is correct electrical connection is made check power cord and extension cord for cuts and breaks 2 Fan blade contacts inside of heater housing Be sure that housing is not damaged Make sure there are no obstructions to the fan 3 Fan blade s bent Straighten blade s to match others 4 Fan motor defective Replace motor 2 Heater will not fire 1 No spark at ignitor Check ignitor wire Re attach or tighten if loose Check Spark module Replace if necessary 2 Improper spark gap Set gap See specifications for gap 3 Bad electrode Replace Spark Plug 3 Heater quits while 1 Internal temperature too high causing limit If the heaters output is restricted internal temperature running Switch to shut down operation becomes too high Move heater away from any obstructions 2 Damage
6. 256 William Penn Hwy Mill Creek PA 17060 0192 Tel 1 800 776 9425 www worldmkting com SAVE THIS CARD Place Postage Stamp Here World Marketing of America Inc PO Box 192 12256 William Penn Hwy Mill Creek PA 17060 0192
7. B ASSY SCREW REGULATOR amp HOSE ASSEMBLY NIN 6 5 E 12 EA Lee Es Le EN MES E de 182 201 EA EN 2 241 HE NEM 2 PROPANE CONSTRUCTION HEATER ILLUSTRATED PARTS BREAKDOWN MODELS GFA40 GFA50A GFA60A REPLACEMENT PARTS LIST PART NUMBER NO DESCRIPTION QTY GFA100A GFA125A 150 SHELL IN ASSY 2304929 2304929 2304929 2001355 2001355 2001355 raso has aa s muemwocouerASsv arare 9 Tao o Ex screw 2901888 2901888 aa 30 30 1 32 2001355 2001355 2001355 CORD WRAP 2101423 2101423 2101423 301 SCREW 4 2001081 2101423 2001081 HOSE 13 PROPANE CONSTRUCTION HEATER ILLUSTRATED PARTS BREAKDOWN MODELS GFA100A GFA125A GFA150A 14 THIS PAGE INTENTIONALLY LEFT BLANK WARRANTY LIMITED WARRANTY This limited warranty is extended to the original retail purchaser of this Duraheat Forced Air Convection Radiant Heater and warrants against any defect in materials and workmanship for a period of one 1 year from the date of retail sale World Marketing of America Inc at its option will either provide replacement parts or replace or repair the unit when properly returned to the retailer where pu
8. LOW JAUNE THERMOCOUPLE AMARILLO THERMAL SWITCH TERMOPAR THERMOCONTACTEUR INTERRUPTOR T RMICO If any original wiring supplied with the Si vous devez faire remplacer les fils Si se proporciona cualquier heater must be replaced it must be type d origine du radiateur procurez vous cableado con el calentador se AWG 105 C wire or its equivalent du fil AWG 105 Celsius ou l quivalent debe reemplazar debe ser cable except as indicated sauf indication contraire tipo AWG 105 C o su equivalente excepto como se indica 10 REPLACEMENT PARTS LIST PART NUMBER GFASOA 3504942 IUD 0135 550465 3504549 3504937 3504055 DIES 2304977 3502053 DESCRIPTION 2 e e SHELL IN ASSY HOLDER THERMAL SWITCH BRACKET SPARK PLUG ASSY OCOUPLE ASSY 1130 1474 425L d lt o ulw Q uju o o o AREER 5 e ERAS E 5 SHE 2 BING ASSY 0 11 11 1 11 2 11 3 12 12 1 12 2 12 3 13 13 1 1 HANDLE ASSY MOTOR SUPPORT BOLT BOLT MOTOR ASSY MOTOR FAN MOTOR BRACKET A 5 1 17 18 18 1 18 2 ON POWER CORD ASSY CAPACITY SCREW 20 20 1 21 22 224 HEIGHT CONTROLLER BASE ASSY HEIGHT CONTROL SCREW VALVE BRACKET N 4 24 1 N Un S un S Ds S oo 5 2 Et gt gt N 6 7 8 28 1 2 LEAD WIRE ASSY SPARK MODULE PC
9. NTENANCE INCLUDING CLEANING WILL VOID THIS WARRANTY THIS LIMITED WARRANTY IS GIVEN TO THE PURCHASER IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE THE REMEDY PROVIDED IN THIS WARRANTY IS EXCLUSIVE AND IS GRANTED IN LIEU OF ALL OTHER REMEDIES IN NO EVENT WILL WORLD MARKETING OF AMERICA BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you CLAIMS HANDLED AS FOLLOWS 1 Contact your retailer and explain the problem 2 If the retailer is unable to resolve the problem contact our Consumer Warranty Dept detailing the heater model the problem and proof of date of purchase 3 A representative will contact you DO NOT RETURN THE HEATER TO WORLD MARKETING OF AMERICA INC unless instructed by our Representative This warranty gives you specific legal rights and you may also have other rights which vary from state to state 5 TO REGISTER THE WARRANTY ON YOUR HEATER PLEASE FILL OUT THIS CARD COMPLETELY E AND MAIL WITHIN 14 DAYS FROM DATE OF PURCHASE OR REGISTER ON LINE AT www worldmkting com PHONE EMAIL ADDRESS CITY STATE
10. ZIP MODEL SERIAL DATE PURCHASED DEALER PURCHASED FROM TYPE OF STORE CITY amp STATE WHERE PURCHASED PRICE PAID Please Take a Minute To Give Us Your Answers To The Following Questions All Responses Are Used Solely For Market Research And Are Held In Strict Confidence Who primarily decided this purchase O Male Female 0 18 24 O 25 39 140 59 160 and over Purpose of Purchase Do you own any other portable heaters Yes 0 No If yes type brand How do you intend to use your new heater Construction Site Farm Warehouse Commercial O Garage Outbuilding 0 Other How did you become aware of this heater In Store Display NewspaperAd Magazine Ad Friend Relative Commercial Store Salesperson Other What made you select this heater Style Size Portability Price Package Brand Other l Do you O own 0 rent Would you recommend this heater to a friend Yes Please give us your comments THANK YOU FOR COMPLETING THIS FORM Information will be held confidential Part O9LPWTY 16 WARRANTY REGISTRATION IMPORTANT We urge you to fill out your warranty registration card within fourteen 14 days of date of purchase You can also register your warranty on the internet at www worldmkting com Complete the entire serial number Retain this portion of the card for your records World Marketing of America Inc PO Box 192 12
11. cts or other reproductive harm Wash hands after handling A WARNING NOT FOR HOME OR RECREATIONAL VEHICLE USE 2 DURAHEAT FORCED AIR CONSTRUCTION HEATERS The heater is designed and approved for use as a construction heater under ANSI Z83 7a CSA 2 14a It is hard to anticipate every use which may be made of this heater CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT APPLICATIONS Other standards govern the use of fuel gases and heat producing products in specific applications Your local authority can advise you about these IMPORTANT READ THIS USER S MANUAL CAREFULLY AND COMPLETELY BEFORE TRYING TO OPERATE OR SERVICE THIS HEATER IMPROPER USE OF THIS HEATER CAN CAUSE SERIOUS INJURY OR DEATH FROM FIRE EXPLOSION AND CARBON MONOXIDE POISONING This is a direct fired forced air construction heater for either indoor construction or outdoor use Its intended use is primarily the temporary heating of buildings or structures under construction alteration or repair All the products of combustion generated by the heater are forced through the heater and released into the area being heated This heater operates at approximately 98 combustion efficiency but still produces a small amount of carbon monoxide Humans can tolerate small amounts of carbon monoxide for short periods Carbon monoxide can build up in a heated space and failure to provide adequate ventilation could result in poisoning or death
12. d Control Valve Replace Control Valve 3 Dust or debris build up inside of heater Clean inside of heater Always be sure to follow proper maintenance procedures by cleaning the heater once per month during regular usage and check spark gap at least once per season WIRING DIAGRAMS PIEZO MANUAL SPARK MODELS MODELES TINCELLE PI ZO LECTRIQUE MANUELLE MODELOS DE CHISPA MANUAL O PIEZOELECTRICA CONDENSER CONDENSATEUR WHITE CONDENSADOR BLANC pem D Og UT s BLUE BLEU AZUL m Zz 228 WHITE BLANC BLANCO lt gu zz 9 9 BLACK NOIR NEGRO lt 550 WHITE BLANC BLANCO E uo BLACK NOIR NEGRO 2 ES zx pH GREEN VERT VERDE O gt gt POWER CORD PCB RELAY RELAIS PCB PCB RELEVADOR CORDON D ALIMENTATION CABLE DE ENERGIA EARTH SHELL _ ENVELOPPE EXT RIEURE TIERRA CUBIERTA EARTH LA TERRE TIERRA BLUE BLEU AZUL YELLOW JAUNE AMARILLO THERMAL SWITCH THERMOCONTACTEUR IGNITOR INTERRUPTOR TERMICO ALLUMAGE ENCENDIDO YELLOW JAUNE AMARILLO BLACK NOIR NEGRO se proporciona cualquier If any original wiring supplied with Si vous devez faire remplacer les cableado con el calentador se the heater must be replaced it must fils d origine du radiateur procurez debe reemplazar debe ser be type AWG 105 C wire or its vous du fil AWG 105 Celsius ou cable tipo AWG 105 o su equivalent except as i
13. earances to combustible construction Side 24 61cm Top 36 91cm Front 72 1 8M Floor combustible must be maintained at all times The hose assembly should be visually inspected prior to each use of the heater If it is evident that there is excessive abrasion or wear or the hose is cut it must be replaced prior to the heater being put into operation The replacement hose assembly shall be that specified by the manufacturer Refer to parts list LIGHTING INSTRUCTIONS WARNING Motor and fan must be running before lighting during operation and shutdown in order to prevent a flame out condition which could result in personal injury or property damage Connect power cord to a properly grounded three 3 prong 120V 60Hz single phase receptacle Turn gas valve knob clockwise to OFF position Wait five 5 minutes to clear any gas Then smell for gas if you don t smell gas go to next step Turn gas supply ON by turning Propane tank valve counterclockwise Push in and turn gas control knob counterclockwise to LOW IGN This will light the burner If needed keep pressing control knob until the burner lights and keep depressing and turning from OFF to LOW IGN on Piezo electric spark models HIGH IGN In case of FA40 series Keep the valve knob depressed for at least 30 seconds after lighting the burner After 30 seconds release valve knob If burner does not stay lit repeat the lighting procedure
14. ize amp Capacity Of Propane 5 e Installation To The Propane Gas Tank 2 3 era a a 6 e Refilling The Propane Gas Tank x 24 3 ur Eu b a ER SUPR E E ERES 6 e Leak Checking amp Positioning Heater x unies ane 25 Bear mn mean ee 7 e Lighting amp Shutdown Instructions eo ios seda e 7 8 Test Firing Heater amp Storage ouais ew STORE RERO REOR ERROR CES eek oe 8 TOUDIESNOOUNG 2 23 2 2 C rl e a a oes 8 Winnog DIS SITIS oit mend 9 10 Replacement Paris bist os a a da 11 13 CONSTRUCTION HEATER ILLUSTRATED PARTS BREAKDOWN GEAADFGFABDAFGERBDR oiu meth dieere bles ode saut ete Oed ilte 12 GEA OOF sunset xus Taro 14 Warranty catar bs 16 WARNING BURN INHALATION AND EXPLOSION HAZARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PRODUCTS SUCH AS GASOLINE SOLVENTS PAINT THINNERS DUST PARTICLES OR UNKNOWN CHEMICALS CALIFORNIA PROPOSITION 65 WARNING This product contains chemicals including lead and lead compounds a chemical known to the state of California to cause birth defe
15. linder supply system must be arranged to provide for vapour withdrawal from the operating cylinder A WARNING Motor and fan must be running before lighting during operation and at shutdown in order to prevent a flame out condition which could result in personal injury or property damage PRODUCT FEATURES Portable amp Stable 100 Safety Shutoff System Wind Resistant amp Rain Protected Adjustable Input Ratings Continuous Spark Ignition or Piezo Electric Spark Ignition gt UNPACKING 1 Remove heater from carton 2 Remove all protective packing applied to heater for shipment 3 Retain cartons and packaging material until unit is operated and found in good condition 4 Check heater for any shipping damage If heater shows any external or internal damage promptly inform dealer distributor where you purchased heater INFORMATION ON SIZE CAPACITY OF PROPANE GAS CYLINDERS The chart below shows the number and size of propane tanks needed to run this heater Less gas is vaporized at lower temperatures You may need two or more 100 pound tanks or one larger tank in colder weather See the parts list for your model of heater to get the specified regulator assembly Number of Tanks Temperature F At tank 100 000 CF 40 000 60 000 BTU h 125 000 BTU h 150 000 BTU h Above 32 F 1 206 2 1006 2 1006 The propane LP gas tank must also be equipped with the following Acollar to protec
16. m the factory for LP Propane gas This heater is for use with propane gas only do not convert heater to any other gas Installation must conform to local codes or in the absence with the standard for the Storage and Handling of Liquefied Petroleum Gases ANSI NFPA NFPA 58 and the Natural Gas and Propane Installation Code CSA B149 1 The minimum and maximum inlet pressures to the regulator from the gas tank are 5 psi and bottle pressure respectively Use only the regulator amp hose assembly provided with the heater Inspect the regulator hose assembly prior to each use of the heater If there is excessive abrasion or wear or hose is cut replace with regulator hose assembly listed on the parts list prior to using this heater Gas supply connections should be checked using a 50 50 solution of liquid dish soap and never use a flame to check for gas leaks The electrical connection amp grounding must comply with National Electrical Code ANSI NFPA 70 or in Canada CSA C22 1 Canadian Electrical Code Part 1 Use only a properly grounded three 3 prong receptacle Do not restrict inlet or outlet by any means The flow of combustion and ventilation air is not to be obstructed Forced air heaters should not be directed toward any propane or gas container within 20 feet 6M of the exit nozzle The heater should also be located at least 6 1 8M feet away from any propane gas container regulations in Canada are 10 feet 3M The propane cy
17. nd wheel that can be used to tighten the fitting This hand wheel can be slid off of the nut so that a wrench can also be used to tighten the fitting Position regulator so that hose leaving the regulator is in a horizontal position see Figure 1 3 Connect hose to heater inlet Tighten firmly using a wrench You must use the regulator supplied with heater 4 Open propane LP supply valve on propane LP tank s slowly NOTE If not opened slowly excess flow device in regulator may stop gas flow If this happens close propane LP supply valve wait one minute or until you hear a click and open again slowly 5 Check all connections for leaks Apply a 50 50 solution of liquid dish soap and water to gas joints Bubbles forming show a leak that must be corrected 6 Close propane LP supply valve before attempting to repair connection WARNING Purging and filling of LP gas tanks must be performed by personnel who has been thoroughly trained in accepted LP gas industry procedures Failure to follow these instructions may result in explosion fire severe personal injury or death REFILLING THE PROPANE GAS TANK ALL NEW CYLINDERS MUST BE PURGED BEFORE THE FIRST FILLING Turn heater gas valve knob and gas tank valve to OFF position Propane tank valve equipped with the old style fitting has LEFT HANDED THREADS Turn POL fitting CLOCKWISE to loosen Protect POL fitting when disconnected from tank Have tank filled by yo
18. ndicated l quivalent sauf indication equivalente excepto como se contraire indica WIRING DIAGRAMS CONTINUOUS SPARK MODELS MODELES TINCELLE CONTINUE MODELOS DE CHISPA CONTINUA WHITE BLANC BLANCO CONDENSER CONDENSATEUR H BLUE BLEU AZUL CONDENSADOR 400K 125K amp 150K Models only 400K 125K amp 150KS lo modelos 100K 125K amp 150K Les mod les Seulement POWER CORD CORDON D ALIM WHITE BLANC BLANCO CABLE DE ENERG A WHITE BLANC BLANCO FUSE FUSIBLE FUSIBLE WHITE BLANC BLANCO 4 BLACK NOIR NEGRO E WHITE BLANC BLANCO GREEN VERT BLACK NOIR NEGRO BLACK NOIR NEGRO GREEN VERT VERDE E WHITE BLANC BLANCO EARTH SHELL n E ENVELOPPE EXT x ne Du RIEURE TES IZA TIERRA CUBIERTA 236 ES Zug 9 lt 2 WHITE BLACK 2 BLANC c x x39 LES r22 amp BLANCO NEGRO 2220 TADE o x m A BLACK E amp x 5310 THE NOIR XEO lt O 025 z NEGRO 50 2 MULTI RECEPTACLE HOUSING Gzuz z So LOGEMENT MULTI DE RECEPTACLE HOLO CAJA DE ENCHUFES MULTIPLES PCB RELAY RELAIS x 9 a RELEVADOR lt 19 uz BLUE BLEU ez CONTROL VALVE YELLOW JAUNE AMARILLO o MN VALVE DE COMMANDE ALT RELAY RELAIS VALVULA DE CONTROL EARTH Aus A LA TERRE nun ENCENDIDO IL MM BLUE BLEU AZUL E THERMOCOUPLE YEL
19. rchased or one of our service centers as directed by World Marketing within one 1 year of retail purchase Shipping costs labour costs etc are the responsibility of the purchaser DUTIES OF THE OWNER This heating appliance must be operated in accordance with the written instructions furnished with this heater This warranty shall not excuse the owner from properly maintaining this heater in accordance with the written instructions furnished with this heater A bill of sale canceled check or payment record must be kept to verify purchase date and establish warranty period Original carton should be kept in case of warranty return of unit WHAT IS NOT COVERED 1 Damage resulting from use of improper fuel Damage caused by misuse or use contrary to the owners manual and safety guidelines Damage caused by a lack of normal maintenance Fuses Use of non standard parts or accessories Damage caused in transit Freight charges on warranty parts or heaters to and from the factory shall be the responsibility of the owner OP ON This warranty does not imply or assume any responsibility for consequential damages that may result from the use misuse or the lack of routine maintenance of this heating appliance A cleaning fee and the cost of parts may be charged for appliance failures resulting from lack of maintenance This warranty does not cover claims which do not involve defective workmanship or materials FAILURE TO PERFORM GENERAL MAI
20. t the Propane gas valve Ashutoff valve terminating a Propane gas cylinder valve outlet as specified in the American National Standards for Compressed Gas Cylinder Valve Outlets and Inlet Connections Asafety relief valve having direct communications with the vapor space of the tank An arrangement of vapor withdrawal The propane LP gas pressure requlator and hose assembly supplied with this heater must be used without alteration The hose assembly shall be visually inspected prior to each use of the heater If it is evident that there is excessive abrasion or wear or the hose is cut it must be replaced prior to the heater being put into operation The replacement hose assembly shall be that specified by the manufacturer INSTALLATION TO THE PROPANE GAS TANK IMPORTANT You must use a propane LP gas supply cylinder that is compatible with the connection device provided with the hose and regulator Propane LP 1 3 Regulator Supply Valve p gt a gt P GET ef Fuel Gas WIN JI Propane LP 2 gh Tank X Fitting Hose to gt gt Heater FIGURE2 gt w Hose to Regulator FIGURE 1 Hose Fitting Connector Inlet 1 Provide propane LP supply system see size capacity page 7 2 Connect fuel gas fitting hose regulator assembly to propane LP tank s Turn fuel fitting counterclockwise into threads on tank Tighten firmly using a wrench Some models have a ha
21. ur local Propane gas supplier Fasten full Propane tank and connect POL fitting to tank valve by turning COUNTERCLOCKWISE With heater gas valve knob still in the OFF position turn ON tank valve and check for leaks with soap solution PROPANE SAFETY Propane is safe to use when properly handled Careless handling of the Propane gas tank could result in fire and or an explosion Therefore Always keep tank cylinder securely fastened in an upright position Avoid tipping tank on its side when connected to a regulator since this may cause damage to diaphragm in regulator Handle valves with care Never connect an unregulated Propane tank to construction heater Do not subject Propane tank to excessive heat Tightly close the gas shutoff valve on the Propane tank after each use The POL fitting must be protected when disconnected from the propane tank Never store a Propane gas tank inside a building or in the vicinity of any gas burning appliance THE DISCONNECTED TANK MUST NEVER BE STORED IN A BUILDING GARAGE OR ANY OTHER ENCLOSED AREA LEAK CHECKING Check all gas connections with a soap solution to be sure they are tight and leak proof The installation of your heater must meet all local codes and or gas utility requirements or in the absence of local codes with the Storage and Handling of Liquefied Petroleum Gases ANSI NFPA 58 and the Natural and Propane Installation Code CSA B149 1 The minimum cl

Download Pdf Manuals

image

Related Search

Related Contents

Tecnoware Netbook Charger 20 Car  技術指導完全マニュアル書 - オートプロジャパンって何?  Vayselle - Fiche de produit  携帯形O2モニター MB1000取扱説明書  Manual Descargar  取扱説明書 - 東洋紡ライフサイエンス事業部  GRAND NETTOYAGE Chaussée de Bruxelles 548A  Stand-alone Type - Security Camera Systems  Read the owners manual carefully before mounting the BG! Owners  CX-Server OPC User Manual  