Home

World Marketing of America Winchester II

image

Contents

1. fireplace 25 SAVE THESE INSTRUCTIONS WARNING Procedures and techniques which if not carefully followed will result in damage to the equipment or personal property or may cause personal injury WARNING Procedures and techniques which if not carefully followed will expose the user to the risk of serious injury illness or death WARNING This is a 1500 watt heater and parts become hot when in use Be sure to main tain a personal distance and keep any combustible material at least three 3 feet away from the front of the heater The area directly behind around and under the heater must be clear and free of any obstructions KEEP CHILDREN AND PETS AWAY FROM HEATER AND CONTROLS LOCATING YOUR ELECTRIC FIREPLACE Your new freestanding electric fireplace may be installed virtually anywhere in your home However when choosing a location for your new electric fireplace ensure that the general instructions are followed For best results install the electric fireplace out of direct sunlight CLEARANCE TO COMBUSTIBLES ELECTRICAL SPECIFICATIONS BAC T 4 0mm Voltage 120 VAC 60Hz Sides 0 0mm Total Amps 11 3 Amps SS EET 0 0mm Total Watts 1500 Watts i cor 24 610mm Heater Ratings 1400 Watts 5 10 Sta 36 915mm ELECTRICAL CONNECTION A 15 AMP 120 Volt 60Hz circuit with a properly grounded outlet is required Preferably the heater will be on a dedicated circuit Other appliances on
2. sE a PSSCIMIDIY The rie sesser arei nn nE EERE ER EEE Aa 4 5 6 Service IISULUCHIONS oes ciccsteccosetiacatndagseeeennensesvagiasrinauadeateancinratinasiadapeddeacenneat 8 PRE DIACING LONI B06 cnet ceca nine cet tecnennacassecmennaanet beaneaneraesecceesaesaeebecneaans 8 Glass Tael Le josaucssseeneossicestssaaiaeestscsaaewsticsstieenorccissentinsaacesstacmancsiaae 8 Maintenance of MOLIOrS eee 8 Cleaning WisWUCHONG 2 c lt ccc casaceatetasaseacesesnecsenagaseeRaeaaoaceatsussausaseeteteaeerese 8 Operating INSIFUClIONS ecc52 cccc5c 22c2cen925 ceasecasenecasieuncedacciseicedeaseiedsanicacsnccasameceeasaaars T TOE SWIG ea aee a r EEEE EE 7 Heater Control 7 Instructions for DOWGT x ee 9 Pece UON nre E EAE E R R 9 Replacement Parts List 00 ccc ccccccseeceeeeeeseeseeteeeeesseeteeeeeeeeeeeeesssssssseesees TO IMPORTANT SAFETY INSTRUCTIONS PLEASE RETAIN THIS USER S GUIDE FOR FUTURE REFERENCE When using electrical appliances basic precautions should always be followed to reduce the risk of fire electric shock and injury to person including the following 1 Read all instructions before using this fireplace 2 This fireplace is hot when in use To avoid burns do not let bare skin touch hot surfaces The grill directly in front fo the heater outlet becomes hot during heater operation Keep combustible materials such as furniture pillows bedding papers clothes and curtains at least 3 feet from t
3. Kozy Worlde EFS524KD Freestanding Electric Fireplace Installation Instructions and Homeowner s Manual ARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY A FIRE MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE FOR YOUR SAFETY b Comfort Home Products Inc 12256 William Penn Hwy Ste A DO NOT STORE Huntingdon PA 16652 OR USE GASOLINE OR US OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE KOZY WORLD PHONE NUMBER 814 643 1775 http www worldmkting com ANSI UL 1278 MOVABLE AND WALL OR CEILING HUNG ELECTRIC ROOM HEATERS INSTALLER DO NOT DISCARD THIS MANUAL LEAVE FOR HOME OWNER CUSTOMER PLEASE RETAIN THIS MANUAL FOR FUTURE USE TABLE OF CONTENTS PLEASE READ THE INSTALLATION amp OPERATIONS INSTRUCTIONS BEFORE USING THIS APPLIANCE IMPORTANT Read all instructions and warnings carefully before starting installation Failure to follow these instructions may result in a possible electric shock fire hazard and will void the warranty Installation instructions CEE 2 CE e TEAT TET T E PE ESE PTT EEE E ETE EET tatanansen ee 2 Locating Your Electric FICDIACC se see e ee scope ieeneuaeiaes bomesser ss 3 Clearance To OM USD ICS is cnceesccccacnsacescesamacesceaaesessccsamnigremieeraaangansadeosan 3 Electrical COMMCC HONS accuse tuaannecssaccenaneeccampavaaanen sosatess ane aeaienten aces erainscetent nis 3 Electrical S0ecincaioOng e e 3
4. NSERT controls are in the OFF position and the INSERT is NOT plugged in CAUTION Place a piece of cardboard or protective sheet on the floor in order to avoid scratching the decorative surface of your mantle during assembly Please DO NOT fully tighten the KD screws until all panels are assembled Step 1 Attach 2 CONNECTORS S to the UPPER FRONT PANEL E with 4 KD SCREWS 2 screws for each side See Figure A Step 2 Attach all PLASTIC CONNECTORS X to the PANELS C D amp E as shown in Figure B 2 screws for each PLASTIC CONNECTOR i i L fig B Step 3 Attach the SIDE PANEL C to the FRONT PANEL D with 6 KD SCREWS 3 screws for each side See Figure C Step 4 Attach the LEFT and RIGHT SIDE PANELS C D amp G to the BASE B using 4 KD SCREWS 2 screws for each side See Figure D F P mAN oo ae L tl pa 4 fig C L L 3 P ni iiia Fh go i qo 0 Ss fig D Step 5 Place the LOWER FRONT PANEL F in between the lower section of 2 FRONT PANELS D and attach with 2 KD SCREWS 1 screw for each side See Figure E Step 6 Carefully place the INSERT into the unit opening The front of INSERT should be flush with the front of the mantle Once the INSERT is in place attach 2 MOUNTING BRACKETS V with 2 KD SCREWS onto the bottom of the INSERT 1 screw for each brack et See Figure F j 00 s R E ih Po E gr fig E P P a i d Le fig F Step 7 Att
5. ach the UPPER FRONT PANEL E in between the upper section of the 2 FRONT PANELS D with 2 KD SCREWS 1 screw for each side See Figure G Step 8 Attach 3 MOUNTING CLIPS U onto the top of INSERT and lock in place with 3 SHORT KD SCREWS T See Figure H Step 9 Install the TOP PANEL A to the unit as shown and attach with 5 KD SCREWS See Figure I Step 10 Tighten all KD SCREWS OPERATING INSTRUCTIONS Once the fireplace heater insert has been properly installed and connected to a ground electrical outlet it is ready to operate Note Ensure the circuit breakers for the power supply are turned on The controls are located behind the grill below front glass and can be accessed by pulling the grill up from the top forward and down Lift front grill to access the switches 1 The round dial on the far left is the thermostat that automatically turns the heaters on and off to maintain a constant temperature Turn the thermostat dial to the right to increase the desired temperature and the left to lower it Once the room reaches the desired temperature turn the thermostat dial counter clockwise until you hear a click Leave in this position to maintain the room temperature at its current setting 2 The switch on the left turns the heater on at 1500 watts Press this switch while the ON OFF switch and the 750W switch are in the on position for high heat The indicator light will turn on 3 The
6. ains internal parts that could arc or spark Do not use it in areas where gasoline paint or flammable liquids are used or stored This electric fireplace should not be used as a drying rack for clothing Also do not have Christmas stockings or decorations hung on or near it 14 Do not modify this fireplace Use it only as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons 15 Avoid the use of an extension cord because it may overheat and cause a risk of fire However if you must use an extension cord the cord shall be NO 16 AWG minimum size and rated not less than 1875 watts 16 Do not burn wood or other materials in this fireplace 17 Do not strike fireplace glass 18 Always use a certified electrician should new circuits or outlets be required 19 Always use properly grounded fused and polarized outlets 20 Always use ground fault protection where required by electrical code 21 Always disconnect power before performing any cleaning maintenance or relocation of the fireplace 22 When transporting or storing the fireplace and cord keep in a dry place free from excessive vibration and store so as to avoid damage 23 Do not plug this product into a receptacle controlled by a wall switch or dimmer 24 Do not exceed recommended bulb wattage Using a higher wattage bulb could create a fire hazard or cause damage to your electric
7. box The adapter should not be used if a three slot grounded receptacle is availabe WARNING Before servicing this heater be sure to unplug heater from wall outlet Do not only turn off heater from the main ON OFF switch be sure to unplug this heater GROUNDING PIN ADAPTER GROUNDING KK MEANS Adaptor NOT permitted in Canada Under CZ22 2 NO 0 standard SPECIFICATIONS Model EF5524KD Voltage 120V 60Hz Total Amps 11 3 Amps Total Watts 1500W Heating Ratings 1400W 5 10 Dimensions Inches H x W x D Fireplace 37 8 x 31 89 x 8 54 Carton 25 6 x 35 1 x 10 9 ar a d T m D 000 E R GKM X m o9 l O R CA KM x Im lt REPLACEMENT PARTS LIST SEC 35 lra ST gt EEDEN 8 fF 6 g 10 11 12 13 14 15 16 DESCRIPTION OEM Front Louver NDF 65NB 04 Firebox Cabinet NDF 65NB 09 PVC Screen NDF 65NB 14 Log Set NDF 65NB 37 Power Cord w plug NDF 65NB 23 Plastic Feet NDF 65NB 66 Rocker Switch NDF 65NB 28 Knob NDF 65NB 32 Flame Generator Motor NDF 65NB 40 Flame Reflector NDF 65NB 45 Bulb NDF 65NB 52 Flame Adjusting NDF 65NB 55 Thermostat NDF 65NB 31 Blower Motor Heater Assembly NDF 65NB 61 Top Panel for Mantel QCM707P 32A A Mantel Base QCM707P 32A B Side Panel for Mantel QCM707P 32A C Front Panel for Mantel QCM707P 32A D Top Front Panel QCM707P 32A E Bottom Front Panel QCM707P 32A F 10
8. brication is required However periodic cleaning vacuuming of the fan heater unit is recommended CAUTION Even though the glass is safety glass it may break if bumped struck or dropped Care must be taken when handling the glass GLASS INFORMATION 1 Under no circumstances should this product be operated with missing or broken glass 2 Do not strike or slam the glass 3 Do not use abrasive cleaners to clean the glass CAUTION Wait until the unit has completely cooled before attempting any cleaning CLEANING To clean the unit first turn off controls on unit and unplug unit from power source To clean the glass door remove dust with clean dry cloth or to remove finger prints and other marks clean glass with clean damp cloth Do not use abrasive cleaners or spray liquids on glass door surfaces Metal and metal painted parts should be cleaned with clean damp cloth only Do not use abrasive cleaners or spray liquids on this surface Help Hints For convenience if one bulb burns out it may be a good idea to replace both of the light bulbs at the same time 8 INSTRUCTIONS FOR POWER This heater is for use on 120 volts only The cord has a plug as shown at A in the following figure An adapter as shown at C is available for connecting three blade grounding type plugs to two slot receptacles The green grounding lug extending from the adapter must be connected to a permanent ground such as a properly grounded outlet
9. he front of the unit 3 CAUTION Extreme caution is necessary when any heater is used by or near children or invalids and whenever the fireplace is left operating and unattended 4 Always unplug fireplace when not in use 5 Do no operate any fireplace with a damaged cord or plug or after the heater has malfunc tioned or if the fireplace has been dropped or damaged in any manner Take fireplace to authorized service facility for examination electrical or mechanical adjustment or repair 6 Do not use outdoors 7 This fireplace is not intended for use in bath rooms laundry areas or similar indoor locations Never locate fireplace where it may fall into a bathtub or other water container 8 Do not install the fireplace directly on carpet or a similar surface which may restrict air circulation beneath the unit 9 Do not run cord under carpeting Do not cover cord with throw rugs runners or the like Arrange cord away from traffic areas and where it will not be tripped over 10 To disconnect fireplace turn controls to the off position and remove plug from outlet 11 Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause electric shock fire or damage to the fireplace 12 To prevent fire do not block air intakes or exhaust in any manner Do not use on soft surfaces such as a bed where openings may become blocked 13 CAUTION This appliance gets hot and it cont
10. middle switch turns the heater on at 750 watts Press this switch while the ON OFF switch is in the on position for low heat The indicator light will turn on 4 The right switch is the main power switch ON OFF Press this button for main power and flame effect The indicator light will turn on 5 The round dial on the right adjusts the intensity of the simulated flame effect Turn this dial until desired flame effect is reached 7 SERVICE INSTRUCTIONS WARNING Disconnect power before attempting any maintenance or cleaning to reduce the risk of fire electrical shock or personal injury REPLACING LIGHT BULBS There are two 2 40W light bulbs located under the logset bed Remove the four 4 screws on the cover located on the back of the fireplace and then remove the rear cover of the unit CAUTION The bulbs in your unit can become extremely hot Allow at least 15 minutes between turning off the unit and removing the light bulbs to avoid hot bulbs coming in contact with the skin To remove bulbs Hold socket and pull the old bulbs out To replace bulbs Hold socket and push in the new bulbs WARNING Do not exceed 40 Watts per light bulb Use of a higher rated bulb may result in a fire causing property damage and personal injury MAINTENANCE OF MOTORS The motors used on both blower fan and flame simulator assembly are prelubricated for the extended warranty of the motor no further lu
11. the same circuit may cause the circuit breaker to trip or the fuse to blow when the heater is in operation The unit comes standard with a 6 1828mm long three wire cord exiting from the rear of the fireplace Plan the installation to avoid the use of an extension cord If an extension cord must be used it must be a minimum 16 AWG three wire with grounding type plug connector and rated no less than 1900 Watts WARNING Do not use this fireplace if any part of it has been under water Immediately call a qualified service technician to inspect the fireplace and replace any part 7 of the electrical system if MULE Y necessary WARNING Electrical outlet wiring must comply with local building codes and all other applicable regulations to reduce the risk of fire electrical shock and ASSEMBLY INSTRUCTIONS NOTE A complete electric fireplace heater should consist of two parts the wooden mantle and the fireplace heater each packed in a separate carton It is not recommended to use the fireplace heater without the wooden mantle Unpack the fireplace heater and mantle Remove all packing materials Pe A ae E PARTS LIST A fA Pda TF A Top panel B Base panel C T C Side panel KD Upper front panel Lower front panel Connector Short KD screws Mounting clips Mounting brackets W KD screws X Plastic connector Front panel D E F S T U V 7 EW M GM X X MM A A WARNING Make sure the fireplace I

Download Pdf Manuals

image

Related Search

Related Contents

Excavadora 240DLC y 270DLC MANUAL DEL OPERADOR      ESP301 - Newport Corporation  ASSMANN Electronic 1m USB 2.0  Garantía (modelos electrónicos) Sugerencias para conservar  LG Electronics RC797T DVD VCR Combo User Manual  HP LC3200N Warranty and Support Guide  IT4 - John Deere  ATTO Technical Manual  