1.  the batteries is in the test mode  do not change  the other battery s   To test additional battery s   you must remove and  reinstall the testing batteries and then reset the mode      lt             15    TRICKLE CHARGING   After the rechargeable battery is fully charged  the charger will give a  small amount of current to the rechargeable batteries to maintain the  fully charged level  This stage is automatically launched after the  rechargeable batteries are fully charged and kept in the charging unit   The    FULL    or    FULLTEST    sign will be displayed on the LCD according  to the mode user selected     CARE AND MAINTENANCE      Extreme temperatures  vibration and shock should be avoided as  these may cause the damage to the unit      When cleaning the displays and casings  use a soft damp cloth    only  Do not wet the exposed metal part of the charging unit  Do  not use solvents or scouring agents as they may mark the LCD    and casing     Do not spill water on the charging unit     Do not make any repair attempt to the units  Take it back to its    original point of purchase for repair by a qualified engineer   Opening and tampering with the units may invalidate its warranty        Do not expose the unit to extreme and sudden temperature  changes  This may damage the electronic parts of the unit     Do not leave unattended while powered  especially in a vehicle     16    SPECIFICATIONS     Input voltage for AC DC adapter  110V AC   240V AC   Input voltage for DC c
2. OF HAZARDOUS LIQUIDS     During the charging process  the    CHARGE    sign is displayed if  any rechargeable batteries are placed into the unit  It is the  responsibility of the user to make sure that the batteries are either  NiCd or NiMH type and not alkaline or carbon batteries     10      Carbon or Alkaline batteries may cause the charger to display the     DEFECT     These types of batteries are NOT suitable for this  charger     DEFECT INDICATOR   The    DEFECT    indicator will flash  Figure 6  for a while on the LCD while  the charger detects the battery condition  If a defective battery condition  is detected  the    DEFECT    sign will remain on until the defective  battery s  are removed     Warning  This charger will not necessarily recognize all types of    defective batteries  Owner discretion is required before attempting to  charge batteries of any condition         i  v If    DEFECT    is displayed  a bad battery has been           placed into the charging unit      Figure 6     11    DISCHARGE MODE   To select the Discharge Mode  press the MODE key for 3 seconds after  the status of the batteries is displayed  Discharge mode will first  discharge the battery  then charge it  When discharging  the     DISCHARGE  sign and battery voltage  Figure 7  will be shown on the    i      Figure 7   R  Discharge Mode    After fully discharging the battery s   they will be re charged again  The  display of voltage and percentage will alternate on the LCD  Once the  batt
3. TABLE OF CONTENTS                                           FCC Disclaimer          Topic Pag  Features 4  Inventory of Contents 5  Operating Modes 6  Charge Mode Lf  Charge Times 9  Defect Indicator 11  Discharge Mode 12  Test Mode 12  Trickle Charge 16  Care and Maintenance 16  Specifications 17  Safety Instruction 18  Warranty Information 19    21          BC 500  BATTERY CHARGER  Instruction Manual    BEFORE USING OUR BATTERY CHARGER  PLEASE READ  ALL INFORMATION CONTAINED IN THIS MANUAL  KEEP THIS  MANUAL IN A SAFE PLACE AS YOU MAY NEED TO USE IT  LATER     Attention     To all users of this device   please follow the safety and  maintenance instructions in this manual  Read the caution  markings on the charger  the manual  and the gift box              CE IC           INTRODUCTION    Congratulations on purchasing the BC 500 charging unit  This device  provides quick and efficient charging of    AA    and    AAA    rechargeable  NiMH or NiCd batteries  The BC 500 offers several charging functions  as well as individual LCD displays for the charging compartments  The  BC 500 charging unit is reliable  user friendly and ideal for use in the  home  office or while travelling  We hope you enjoy your new BC 500  charger     The Charging unit                         CAUTION     The charger is restricted to charging NiCd and NiMH    3    rechargeable batteries only  The charger will not charge ZnMn   NiZn or Li ion batteries  Never use this device to charge other  types of batt
4. apter    START CHARGING BATTERIES    2   3   4   5     zz  After the AC wall adaptor or DC car power  Yyy adaptor has been plugged into an   appropriate power source  Figure 1   insert    Le  a rechargeable battery into the charging     unit and plug the DC jack into the battery     charger  After about 5 seconds the status     will be displayed  along with the battery  voltage  example     1 38V     Then the     CHARGE    sign will be shown on the LCD      Figure 1   AC power adaptor shown        OPERATING MODES OF THE CHARGING UNIT  The charging unit provides three operating modes     A   CHARGE    to charge up the rechargeable battery   Automatically switches to trickle charge after rechargeable battery  is full    2   DISCHARGE       to discharge the rechargeable battery then  charge it for minimizing the memory effect     6    3   TEST  Check the rechargeable battery capacity in Ah     CHARGE MODE   When in this mode  the unit charges the rechargeable battery s   It will  automatically switch to trickle charging after the rechargeable battery is  fully charged     During the charging process  the display will show the    CHARGE    sign  on the LCD  It will also show alternate between the percentage  Figure  3  of the battery charged  and the voltage  Figure 2  of the battery     a    Indication of Voltage  battery charging  a   Figure 2   Bu p  Indication of L ercentage          _         battery charging i     Figure 3     Once the battery is full  the voltage will disp
5. ar adaptor  12V DC   Input voltage for Charger Unit  12V DC  use supplied adaptors  only    Charging current  Approximately 500mA  each battery    Max charging capacity  capacity of rechargeable batteries    3000mAh   Dimensions  L x H x W    Charging unit  2 60    x 4 87    x 0 88     66  x 123 8 x 22 3 mm     LIABILITY DISCLAIMER     The manufacturer and supplier will not accept any responsibility on the  improper or incorrect use that makes any consequence occur    Any performance of repairs or alternations by any person other than the  original supplier will invalidate the warranty    This product is designed to be used only by people who have read and  understood this instruction manual    The specifications of this product may be subject to change without any prior  notice    This product is not a toy  Keep it away from children    User cannot reproduce any part of this manual without the written consent of  the manufacturer     17    ATTENTION   WARNINGS AND SAFETY INSTRUCTIONS   Please carefully read the following important safety instructions     As stated above  only use NiCd or NiMH rechargeable batteries   The unit is for indoor use only  Do not expose it to humidity  Do  not place it in water or submit it to rain and or snow  Do not store  or use it near extreme heat  Keep batteries away from fire    Do not use any accessory not supplied with the charger  The user  should never use any power cable or transformer other than  those originally supplied with the char
6. by email    www lacrossetechnology com support     La Crosse Technology    on the Web  www lacrossetechnology com       FCC disclaimer  This device complies with part 15 of the FCC rules  Operation is subject to the following two    conditions    1  This device may not cause harmful interference    2  This device must accept any interference received  including interference that    may cause undesired operation     All rights reserved  This handbook must not be reproduced in any form  even in  excerpts  or duplicated or processed using electronic  mechanical or chemical  procedures without written permission of the publisher     This handbook may contain mistakes and printing errors  The information in this  handbook is regularly checked and corrections made in the next issue  We accept no  liability for technical mistakes or printing errors  or their consequences    All trademarks and patents are acknowledged     21    
7. eries  such as alkaline  lithium  carbon zinc battery  or any other type of battery that is not specified     The charging unit shall only be used at normal indoor room  conditions     Always follow the charging instructions for the rechargeable  battery     Never use other kinds of power cables or AC wall adaptors  apart from those originally supplied with the charging unit     The rechargeable battery s  may become hot during charging   Take extra care when removing the battery after charging     Unplug the charging unit from the power source when it is not in  use     FEATURES  Charging unit      Roughly 500mA charging current   Individual LCD display for different compartments   Ability to charge both    AA    and    AAA    rechargeable batteries    4    simultaneously       Minus delta voltage   dV  detection for charge termination      Defective battery detection      Discharge mode  first discharging and then charging  to remove  memory effect of rechargeable batteries      Test function to check the capacity of rechargeable batteries      The charging discharge test function can be launched    independently and simultaneously for each rechargeable battery  in the compartments      The LCD of the charger displays the operating status of the  different modes      Trickle charging is available after the rechargeable battery is fully  charged     INVENTORY OF CONTENTS   T  Charging unit    AC wall adaptor    Instruction Manual    2 x AA Rechargeable batteries  Car plug ad
8. ery is full  the voltage will be displayed with the    FULL    sign  The  charger will switch to trickle charge with around 5  of the charging  current to keep the rechargeable batteries full        Discharging voltage    TEST MODE  Press the MODE key for 5 seconds after the status of the batteries is  displayed  and the Test mode can be selected  In Test mode the    12    rechargeable batteries will first be fully charged and then discharged to  determine the battery s  capacity s   They are then fully charged again     During the first charging cycle  the display of current  Figure 8  and  voltage  Figure 9  will alternate on the LCD   Ut me charging current  f  WA   Figure 8  THARGE  TES Test mode  ler Tre charging voltage   Figure 9   CHARGE   TE Test mode          13    When in the discharging stage  the voltage  Figure 10  and discharging  capacity  Figure 11  are displayed alternately            45 The voltage   Figure 10   V  DISCHARGE  TEST Test mode      35       The discharging capacity     Figure 11    fScHARGE  TEST    During the second charging cycle  the voltage and the total capacity are  displayed alternately     m     gt   7       Test mode             14    When the rechargeable batteries are fully charged  the capacity  Ah    Figure 12  and the voltage  V   Figure 13  will be shown alternately with     FULLTEST    displayed on the LCD     eo    Tre capacity       Ah     Figure 12   Test mode  L   The voltage   Figure 13   Test mode    Note  When any one of
9. ging unit    Disconnect the AC DC adapter when the unit is not in use    Do not leave the charger unattended while powered  especially in  a vehicle    Do not operate the charger if it has received a blow or has been  subject to any damage    Do not use the battery charger any purposes other than the one  originally intended by the manufacturer    Do not open or and disassemble the charger  Such handling may  result in the risk of electric shock or fire    User can reset the function of the product that is subject to the  electrostatic discharge disturbance and surge  Please follow the  instruction described in this manual to reset the function for  normal operation        18    WARRANTY  La Crosse Technology     Ltd provides a 1 year limited warranty on this product against  manufacturing defects in materials and workmanship     This limited warranty begins on the original date of purchase  is valid only on products  purchased and used in North America and only to the original purchaser of this product   To receive warranty service  the purchaser must contact La Crosse Technology     Ltd  for problem determination and service procedures  Warranty service can only be  performed by a La Crosse Technology     Ltd authorized service center  The original  dated bill of sale must be presented upon request as proof of purchase to La Crosse  Technology     Ltd or La Crosse Technology     Ltd   s authorized service center     La Crosse Technology     Ltd will repair or replace this p
10. in your owner   s manual    5  damage resulting from the performance of repairs or alterations by someone other  than an authorized La Crosse Technology     Ltd authorized service center   6  units  used for other than home use  7  applications and uses that this product was not  intended or  8  the products inability to receive a signal due to any source of  interference   This warranty covers only actual defects within the product itself  and  does not cover the cost of installation or removal from a fixed installation  normal set   up or adjustments  claims based on misrepresentation by the seller or performance  variations resulting from installation related circumstances    LA CROSSE TECHNOLOGY     LTD WILL NOT ASSUME LIABILITY FOR  INCIDENTAL  CONSEQUENTIAL  PUNITIVE  OR OTHER SIMILAR DAMAGES  ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS PRODUCT   THIS PRODUCT IS NOT TO BE USED FOR MEDICAL PURPOSES OR FOR PUBLIC   INFORMATION  THIS PRODUCT IS NOT A TOY  KEEP OUT OF CHILDREN   S  REACH     This warranty gives you specific legal rights  You may also have other rights specific to  your State  Some States do no allow the exclusion of consequential or incidental  damages therefore the above exclusion of limitation may not apply to you     For warranty work  technical support  or information contact     La Crosse Technology     Ltd  2809 Losey Blvd  South  La Crosse  WI 54601  Phone  608 782 1610  Fax  608 796 1020    20    To contact Customer Support   Warranty Work 
11. lay the    FULL    sign  see    Figure 4     H2       FULL    sign shows  The  FULL battery is fully charged    The trickle charging then starts providing around 5  of the charging  current to keep the rechargeable batteries full      Figure 4     The estimated charging time of the different battery sizes is tabulated in  Table 1     Table 1  Charging Time with Two Types of Battery Size  Size of Battery Charging current  mA  Estimated  battery Capacity charging time  AA 2600mAh  6 hrs  around 500mA  AAA 1000mAh  2 hrs  Notes                                   The default charging current is around 500mA     The actual charging current of rechargeable batteries depends on  their condition and is controlled by the charger  It Is not user  selectable   In the case that the power source terminates  the charger will  reset  Once the power source is back to normal  the battery s  will  be treated as newly installed battery s   For a proper reset   unplug the DC jack and wait 5 seconds before plugging it back  into the charger     When the AC wall adaptor is first plugged into the power source   all the segments light up momentarily and then the version  number of the charger  for example    48     is displayed    If no batteries are in the unit  the          sign is displayed  see Figure  5             ig displayed when no battery s  are in  the charging unit     B  Figure 5     IF ATTEMPTING TO RECHARGE ALKALINE OR CARBON  BATTERIES  IT MAY CAUSE RUPTURE  EXPLOSION OR THE  LEAKAGE 
12. roduct  at our option and at no  charge as stipulated herein  with new or reconditioned parts or products if found to be  defective during the limited warranty period specified above  All replaced parts and  products become the property of La Crosse Technology     Ltd and must be returned to  La Crosse Technology     Ltd  Replacement parts and products assume the remaining  original warranty  or ninety  90  days  whichever is longer  La Crosse Technology     Ltd  will pay all expenses for labor and materials for all repairs covered by this warranty  If  necessary repairs are not covered by this warranty  or if a product is examined which is  not in need or repair  you will be charged for the repairs or examination  The owner  must pay any shipping charges incurred in getting your La Crosse Technology     Ltd  product to a La Crosse Technology     Ltd authorized service center  La Crosse  Technology     Ltd will pay ground return shipping charges to the owner of the product  to a USA address only     Your La Crosse Technology     Ltd warranty covers all defects in material and  workmanship with the following specified exceptions   1  damage caused by accident   unreasonable use or neglect  including the lack of reasonable and necessary  maintenance    2  damage occurring during shipment  claims must be presented to the    19    carrier    3  damage to  or deterioration of  any accessory or decorative surface   4   damage resulting from failure to follow instructions contained 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Feuille de score de débitmètre de pointe. Mode d`emploi : 1 2 3 4  Blodgett KTT-20DS User's Manual    Benutzerhandbuch LCD Multifunktions  REDCENTRIC AGENT FOR LINUX VERSION 7.21.5429A  TODE User Manual  D08-8C、D08-8CM Instruction Manual  Software Requirements Specification Template  Manual de usuario    Copyright © All rights reserved. 