Home
Oregon Scientific BAR206A
Contents
1. various locations to get the best results CLOCK This product is designed to synchronize its clock automatically with a clock signal BAR206 Slide EU UK to select the signal received EU DCF 77 signal within 1500 km 932 miles of Frankfurt Germany UK MSF 60 signal within 1500 km 932 miles of Anthorn England BAR206A e WWVB 60 signal within 3200km 2000 miles of Fort Collins Colorado To enable disable signal reception Press and hold to enable or W to disable signal reception NOTE Reception takes 2 10 minutes If the signal is weak it can take up to 24 hours to get a valid signal If signal reception is unsuccessful place your unit next to a window press and hold to force another signal search Clock signal reception indicator WEAK SIGNAL NO SIGNAL STRONG SIGNAL To set the clock manually disable the signal reception first 1 Press and hold MODE 2 Press A or W to change the settings 3 Press MODE to confirm 4 The settings order is time zone 12 24 hr format hour minute year calendar mode day month month day month day and language BAR206 Time zone offset sets the clock 23 hours from the received clock signal time BAR206A Select the time zone P Pacific E Eastern C Central or M Mountain NOTE The language options are English E German D French F Italian I and Spanish S To select display mode Press MODE to ch
2. Weather Forecast Station with Atomic Time Model BAR206 BAR206A USER MANUAL CONTENTS Overview Front View Back VIEW ainia Mn bencesdececeeesifiayent ina Remote Sensor Getting Started Insert Batteries Remote Sensor N NN RRA Ww ww Clock Reception Manually Set Clock ceccceceeeeteeeeeeeereeeteeeneeeeaees a Weather Forecast Temperature And Humidity Ice Warning Backlight Specifications About Oregon Scientific EU Declaration of Conformity FCC Statement Declaration of Conformity 8 NNNNSoSooou fi OVERVIEW 7 W Increase decrease setting activate deactivate clock reception signal FIG 1 8 Outdoor temperature 9 Weather forecast fa 10 Clock with weekday 11 MEM View current maximum and minimum temperature humidity 12 Ice alert LED indicator 8 5 fo D 10 11 Remote sensor reception indicator Indoor temperature Indoor humidity Clock signal reception indicator MODE Change settings display LIGHT Activate backlight for 5 seconds DOE NS 1 C F Select temperature unit 2 Insert the batteries matching the polarities see FIG 2 2 RESET Reset unit to default settings 3 Press RESET after each battery change 3 EU UK Select the nearest radio signal BAR206 LOCATION Clock alar
3. al display e When disposing of this product ensure it is collected separately for special treatment e Placement of this product on certain types of wood may result in damage to its finish for which Oregon Scientific will not be responsible Consult the furniture manufacturer s care instructions for information e The contents of this manual may not be reproduced without the permission of the manufacturer e Do not dispose old batteries as unsorted municipal waste Collection of such waste separately for special treatment is necessary e Please note that some units are equipped with a battery safety strip Remove the strip from the battery compartment before first use NOTE The technical specifications for this product and the contents of the user manual are subject to change without notice SPECIFICATIONS TYPE DESCRIPTION MAIN UNIT LxWxH 94 x 49 x 164 mm 3 70 x 1 93 x 6 46 in Weight 241 g 8 5 oz without battery Temperature range 5 C to 50 C 23 F to 122 F 0 1 C 0 2 F 433 MHz 25 95 Humidity resolution 1 Resolution Signal frequency Humidity range Power 3 x UM 3 AA 1 5 V batteries REMOTE UNIT THN132N LxWxH 96 x 50 x 22 mm 3 78 x 1 97 x 0 87 in Weight 62 g 2 22 ounces Transmission range 30 m 98 ft unobstructed 20 C to 60 C 4 F to 140 F 1 x UM 3 AA 1 5 V batteries ABOUT OREGON SCIENTIFIC Visit our website www oregonscientific com to learn more about Oreg
4. e in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help The following information is not to be used as contact for support or sales Please call our customer service number listed on our website at www oregonscientific com or on the warranty card for this product for all inquiries instead We Name Oregon Scientific Inc Address 19861 SW 95 Ave Tualatin Oregon 97062 USA Telephone No 1 800 853 8883 declare that the product Product No BAR206 BAR206A Product Name Weather Forecast Station with Atomic Time Manufacturer IDT Technology Limited Address Block C 9 F Kaiser Estate Phase 1 41 Man Yue St Hung Hom Kowloo
5. m and indoor temperature area MEANING Main unit batteries low only Outdoor temperature area Sensor batteries low REMOTE SENSOR The main unit can collect data from up to 3 sensors To set up the sensor 1 Open the battery compartment see FIG 3 2 Select a channel then press RESET 3 Close the battery door 4 Place the sensor within 30 m 98 ft of the main unit using the table stand or wall mount TIP Ideal placements for the sensor would be in any 1 LED status indicator 2 Wall mount hole location on the exterior of the home at a height of not 3 Battery compartment more than 1 5 m 5 ft and which can shield it from direct 4 RESET hole sunlight or wet conditions for an accurate reading 5 CHANNEL switch GETTING STARTED 1 Remove the battery compartment 1 5 m 5 ft NOTE Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing To search for a sensor Press and hold amp MODE The sensor reception icon in the remote sensor area shows the status ICON DESCRIPTION OUT OUT z P i 1 gt 3 Main unit is searching for sensor s 0 A channel has been found The sensor cannot be found MIP The transmission range may vary depending on many factors You may need to experiment with
6. n Hong Kong is in conformity with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation 2007 Oregon Scientific All rights reserved P N 086L00 sample Orecon S CIENT Weather Forecast Station with Atomic Time Model BAR206 BAR206A USER MANUAL
7. on Scientific products If you re in the US and would like to contact our Customer Care department directly please visit www2 oregonscientific Temperature range Power com service support OR Call 1 800 853 8883 For international inquiries please visit oregonscientific com about international EU DECLARTION OF CONFORMITY Hereby Oregon Scientific declares that this Weather Forecast Station with Atomic Time Model BAR206 BAR206A is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC A copy of the signed and dated Declaration of Conformity is available on request via our Oregon Scientific Customer Service www2 CE COUNTRIES RTTE APPROVAL COMPLIED All EC countries Switzerland CH and Norway N FCC STATEMENT This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interferenc
8. oose between clock with seconds weekday calendar WEATHER FORECAST This product forecasts the next 12 to 24 hours of weather within a 30 50 km 19 31 mile radius with a 75 accuracy Sunny Partially Cloudy Cloudy Rainy dti Snowy TEMPERATURE AND HUMIDITY To toggle temperature unit Press C F To auto scan between sensors Press and hold W MEM to display each sensor s data for 3 seconds To end press A To toggle between current minimum and maximum records for the selected sensor Press MEM repeatedly To clear the records Press and hold MEM If the channel 1 sensor falls between 3 C to 2 C 37 F to 28 F LED indicator will flash and will stop flashing once the temperature is out of this range BACKLIGHT Press LIGHT to activate backlight for 5 seconds RESET Press RESET to return to the default settings PRECAUTIONS e Do not subject the unit to excessive force shock dust temperature or humidity e Do not cover the ventilation holes with any items such as newspapers curtains etc e Do not immerse the unit in water If you spill liquid over it dry it immediately with a soft lint free cloth e Do not clean the unit with abrasive or corrosive materials e Do not tamper with the unit s internal components This invalidates the warranty e Only use fresh batteries Do not mix new and old batteries e Images shown in this manual may differ from the actu
Download Pdf Manuals
Related Search
Related Contents
EverFocus EPN4220 User`s manual Electronic Balance: KERN PKP / PKS SRP3004/10 - CONRAD Produktinfo. Ambient ACL 204 Lock-it Box Manual section 1 Copyright © All rights reserved.
Failed to retrieve file