1.     Installer   s Choice and Optional Accessories             Support Brace             Ceiling    Standard Outlet Box    Mounting  gt   Style                      Standard Mounting hangs from the  ceiling by a downrod  included               Angled Mounting recommended for a  vaulted or angled ceiling    Understanding Mounting and Installers Choice       Hunter s patented 2 position mounting system provides you maximum  installation flexibility and ease  You can install your Hunter fan in   one of two ways  depending on ceiling height and your preference   Standard or Angled  The steps in this manual include instructions for  both Installer   s Choice mounting methods     Considering Optional Accessories    Consider using Hunter s optional accessories  including a wall mounted  or remote speed control  To install and use the accessories  follow   the instructions included with each product  For quiet and optimum  performance of your Hunter fan  use only Hunter speed controls     For ceilings higher than 8 feet  you can purchase  Hunter extension downrods  All Hunter fans use    sturdy 3 4    diameter pipe to assure stability and  wobble free performance        A CAUTION  To  reduce the risk of  personal injury  attach  the fan directly to the  support structure of  the building according  to these instructions   and use only the  hardware supplied     5    42441 01     06 14 11     Hunter Fan Company                l   Getting Ready    To install a ceiling fan  be sure you c
2.    P  IS    ode                For reference  also attach your receipt or a copy  of your receipt to the manual     For Your Records and    Warranty Assistance   0  a    3 VI       INI NAI J F  n     Owner s Guide and Installation Manual    Where Purchased           SINCE 1886    Form  42441 01  20110614    2011 Hunter Fan Co           Welcome       Your new Hunter   ceiling fan is an addition to your home or office that  will provide comfort and performance for many years  This installation  and operation manual gives you complete instructions for installing  and operating your fan     We are proud of our work  We appreciate the opportunity to supply  you with the best ceiling fan available anywhere in the world     Before installing your fan  for your records and warranty assistance   record information from the carton and Hunter nameplate label   located on the top of the fan motor housing      Cautions and Warnings    e READ THIS ENTIRE MANUAL CAREFULLY BEFORE BEGINNING  INSTALLATION  SAVE THESE INSTRUCTIONS    e Use only Hunter replacement parts    e To reduce the risk of personal injury  attach the fan directly to the  support structure of the building according to these instructions    1   Getting Ready and use only the hardware supplied    To avoid possible electrical shock  before installing your fan    disconnect the power by turning off the circuit breakers to the   outlet box and associated wall switch location  If you cannot lock   the circuit breakers in the off
3.   including interference that may Transmitter 1 Transmitter 2    cause undesired operation   A WARNING  Use only the Hunter Fan speed control supplied with this fan     4 4  Raise the fan and align the slots in the canopy with the hooks  on the ceiling plate     DIP Switches DIP Switches  Set to 0111 Set to 0100    Note  To hang the fan  you must tilt the canopy to an almost  vertical position so that the canopy slots sit on the ceiling  plate hooks        9  42441 01   06 14 11    Hunter Fan Company                   5    Wiring the Fan    All wiring must be in accordance with national and local electrical  codes and ANSI NFPA 70  If you are unfamiliar with wiring  use a  qualified electrician            omen 5 1  Make sure the power is still off     5 2  To connect the wires  hold the bare metal leads together and place  a wire connector over them  then twist clockwise until tight  For  all these connections use the wire connectors provided     A CAUTION  Be sure no bare wire or wire strands are visible after  making connections      A  lt  gt  5 3  Using a large wire connector  connect the ground wire from the       Receiver   ceiling to the green ground wire from the ceiling plate and the  Steps 5 3   5 7 green ground wire from the downrod        5 4  Using the large wire connectors  connect the white wire and the  black wire from the ceiling as follows     e The white  Common  power wire from the ceiling to the white       wire from the receiver  marked on white tag    N
4.  WARNING  Fan may fall if not assembled as directed in these  installation instructions    3 1  Unbundle the wires from the fan    For Standard or Angled mounting     3 2  Insert the downrod through the canopy and canopy trim ring   Feed the wires from the fan through the downrod on one side of  the pin in the ball     3 3  Loosen the square head setscrew on the adapter to install the pipe  and ball assembly  Note  When the pipe and ball assembly is fully  installed  2 3 threads on the pipe will still be visible  this is normal   Securely retighten the setscrew with a wrench or pliers     A CAUTION  The adapter has a special coating on the threads  Do   not remove this coating  the coating prevents the downrod from   unscrewing  Once assembled  do not remove the downrod   Hanging the Fan     Note  To hang the fan  you must tilt the canopy to an almost vertical  position so that the canopy slots sit on the ceiling plate hooks     3 4  Raise the fan and align the slots in the canopy with the hooks on  the ceiling plate     3 5  Place the slots over the hooks to hang the fan     8       Standard or Angled Mounting          Steps 3 2   3 3     lt m    Downrod     lt  lt  Canopy          lt     Canopy  Setscrew   Trim Ring    Gk l                       42441 01     06 14 11   Hunter Fan Company                4   Setting the Remote Transmitter and Receiver    i i Receiver DIP  Setting DIP switches switches    When two or more fans are located near each other  you may desire  to ha
5.  inches of lead wires extend from outlet box        Suitable Existing Fan Site       Fan Support  System    Outlet Box          If your existing fan site is suitable  skip ahead to Section 2    Installing the  Ceiling Plate     3    42441 01     06 14 11   Hunter Fan Company                Ceiling  Height          Preparing the Fan Site  continued     Step 2   Cut the Ceiling Hole   2 1  Locate the site for the ceiling hole directly below the joist or support brace that  will hold the outlet box and fan    2 2  Cut a 4    diameter hole through the drywall or plaster of the ceiling  You will use  the hole to install the support brace and outlet box     Step 3   Install a Support Brace  If Necessary    Determine if there is a ceiling joist directly above the ceiling hole  If the joist is there    determine if it is positioned to allow you to recess the outlet box a minimum of   1 16    into the ceiling  If NOT  install a support brace as follows    3 1  Attach a 2    x 4    support brace between two joists  Position it to allow you to  recess the bottom of the outlet box a minimum of 1 16    into the ceiling    3 2  Check the support brace to ensure it will support the full weight of the fan and  light kit     Step 4   Install the Outlet Box    4 1  Obtain a UL approved octagonal 4    x 1 1 2    outlet box  plus two  8 x 1 1 2     wood screws and washers  available from any hardware store or electrical supply  house     4 2  Orient the outlet box so that both the inner and oute
6.  kit mounting plate  Failure to properly attach  and tighten all three assembly screws could result in the light kit top  housing and light fixture falling     13  42441 01     06 14 11    Hunter Fan Company             Housing  Assembly  Screw    8 5     8 6           8 e Completing Your Installation With a Bowl Light Fixture  Continued     To attach the light kit  connect the upper plug connector from the  motor to the lower plug connector in the light kit     Note  Both plug connectors are polarized and will only fit together  one way  Make sure the connectors are properly aligned before  connecting them  Incorrect connection could cause improper  operation and damage to the product     Place the light kit over the light kit top housing  Align the holes  in the light kit top housing with the light kit  Attach the light kit  to the light kit top housing with three housing assembly screws   Tighten all three screws firmly     14                kham       i                                l  Housing Light Kit  Assembly Screw  Steps 8 5   8 6          Plug A    Connector  Detail             Housing    Assembly Screw    42441 01     06 14 11     Hunter Fan Company                8   Completing Your Installation With a Light Fixture  Continued     Installing the Glass Bowl   8 7  First install the included CFL bulbs into  the sockets    8 8  Lift the glass bowl up to the light kit top  housing  Align the three tabs in the glass  bowl with the three slots in the light kit  top hou
7.  location without a dimming control     If you need parts or service assistance  please call  888 830 1326  In Canada  call 866 268 1936  or  visit us at our website at  http   www hunterfan com     Hunter Fan Company  7130 Goodlett Farms Parkway  400  Memphis  Tennessee 38016    18  42441 01     06 14 11    Hunter Fan Company                
8.  position  securely fasten a prominent   warning device  such as a tag  to the service panel    All wiring must be in accordance with national and local electrical   codes and ANSI NFPA 70  If you are unfamiliar with wiring  use a   qualified electrician    To reduce the risk of personal injury  do not bend the blade   attachment system when installing  balancing  or cleaning the fan    Never insert foreign objects between rotating fan blades    To reduce the risk of fire  electrical shock  or motor damage  do not   use a Solid state speed control with this fan  Use only Hunter speed   controls  which are solid state    10   Operating and Cleaning Your Ceiling e This product conforms to UL STD 507 and is certified to STD C22 2  No 113   e Wash your hands after your fan installation is complete     Table Of Contents    2    Installing the Ceiling Plate  3 e Assembling and Hanging the Fan    8    4 e Setting the Remote Transmitter and  Receiver    8    Completing Your Installation With a  Light Fixture    9    Operating the Remote Control and  Mounting the Holder          2011 Hunter Fan Company 9    42441 01     06 14 11     Hunter Fan Company                Preparing the Fan Site    Step 1   Choose the Fan Site    Proper ceiling fan location and attachment to the building  structure are essential for safety  reliable operation  maximum  efficiency  and energy savings     Choose a fan site where     e No object can come in contact with the rotating fan blades during  normal op
9. EUTRAL IN      e The black power wire from the ceiling to the black wire from  Large Wire the receiver  marked on red tag    LIVE IN      Connector 5 5  Using the small wire connectors  connect the wires from the fan as    follows   e The black wire with a white stripe from the fan to the red wire  from the receiver  marked on white tag    LIGHT OUT      Small Wire e The black wire from the fan to the black wire from the receiver  Connector  marked on white tag    FAN OUT      e The white wire from the fan to the white wire from the receiver   marked on white tag    COMMON OUT       5 6  Check each connection to make sure no bare wire or wire strands  are visible  Push all wires and wire connectors  except for the white  antenna wire from the receiver  back through the ceiling plate into  the outlet box    5 7  Position the receiver in the canopy so that the antenna is close to  the edge of the ceiling plate for clear reception     10  42441 01     06 14 11     Hunter Fan Company                6   Installing the Canopy and Canopy Trim Ring    A WARNING  Failure to complete the following steps could cause the fan  to fall     Note  It is recommended you use a magnetic tip screwdriver for the  following steps     6 1     6 2     6 3     6 6     Rotate the hanger ball so the tab in the canopy is secure in the  hanger ball groove  Note  Your fan may have multiple tabs and  grooves that must be aligned     Swing the fan up to align the canopy screw holes with the  mounting holes 
10. an do the following   e Locate the ceiling joist or other suitable support in ceiling   e Drill holes for and install wood screws   e Identify and connect electrical wires   e Lift 40 pounds     If you need help installing the fan  your Hunter fan dealer can direct  you to a licensed installer or electrician     Gathering the Tools  You will need the following tools for installing the fan   e Electric drill with 9 64    bit  e Standard screwdriver  magnetic tip recommended   e Phillips head screwdriver  magnetic tip recommended   e Wrench or pliers    e Ladder  height dependent upon installation site     Checking Your Fan Parts    Carefully unpack your fan to avoid damage to the fan parts  Refer to  the included Parts Guide  Check for any shipping damage to the motor  or fan blades  If any parts are missing or damaged  contact your Hunter  dealer or call Hunter Technical Support Department at 888 830 1326    In Canada  call 866 268 1936      6       Installing Multiple Fans   If you are installing more than    one fan  keep the fan blades and  blade irons  if applicable  in sets   as they were shipped        42441 01     06 14 11   Hunter Fan Company                   2   Installing the Ceiling Plate    A CAUTION  To avoid possible electrical shock  before installing your fan  Toward  disconnect the power by turning off the circuit breakers to the outlet box Ceiling Peak  and associated wall switch location  If you cannot lock the circuit breakers    in the off position  secu
11. en back on  The light kit will turn on at  maximum brightness    10 2  Press the remote control   s HIGH speed button  The fan should  start and reach its maximum speed     Note  For everyday operation  leave the wall switch ON  If the  In warm weather  use remote control will not be used for 5 days or more  turn the wall  downward air flow pattern switch OFF        10 3  Ceiling fans work best by blowing air downward   counterclockwise blade rotation  in warm weather to cool the  room with a direct breeze  In cold weather  having the fan draw  air upward  clockwise blade rotation  will distribute the warmer  air trapped at the ceiling around the room without causing a  draft     10 4  For cleaning finishes  use a soft brush or lint free cloth to prevent  scratching  A vacuum cleaner brush nozzle can remove heavier  dust  Remove surface smudges or accumulated dirt and dust  using a mild detergent and a slightly dampened cloth  You may  use an artistic agent  but never abrasive cleaning agents as they  will damage the finish     10 5  The blades on this fan have been treated with Hunter s Dust   In cold weather  use upward Armor protection  making the blades less likely to attract dust  air flow pattern and dirt  Use a dry or slightly damp lint free cloth to clean the  blades  Do not use a furniture polish or any other cleaners that  leave any residue  as they will damage the protective Dust Armor  on the blades        To Change Airflow Direction  Remove glass  Turn switch to 
12. eration     e The fan blades are at least 7 feet above the floor and the ceiling is  at least 8 feet high        The fan blades have no obstructions to airflow  such as walls or  posts  within 30 inches of the fan blade tips     e The fan is directly below a joist or support brace that will hold the  outlet box and the full weight of the fan     Checklist for Existing Fan Site    e a  30    From  Wall or  Nearest    Obstruction 7    Minimum  Blades to  Floor       8    Minimum       If you want to use an existing fan site  complete the following checklist to Fan Support    determine if the site is acceptable and safe for your new Hunter fan  If you  cannot check off every item  prepare a new fan site as described on this    page    Fan Support System      Fan attaches directly to building structure    e Fan support system will hold full weight of the fan and light kit    Ceiling Hole      The outlet box clearance hole is directly below the joist or support brace   Outlet Box    e The outlet box is an UL approved octagonal 4    x 1 1 2    outlet box  or as  specified by the support brace manufacturer      e The outlet box is secured to the joist or support brace by wood screws  and washers through the inner holes of outlet box     e The outer holes of the outlet box are aligned with joist or support brace    e The bottom of the outlet box is recessed a minimum of 1 16    into  ceiling    Wiring   e The electrical cable is secured to outlet box by an approved connector    e Six
13. he bottom of the motor  Note  Some blade mounting screws are  installed in the motor to secure the metal shipping ring     7 4  For each blade iron  insert one blade mounting screw through the  blade iron  and attach loosely to the fan  Insert the second blade  mounting screw  then securely tighten both mounting screws     Steps 7 1   7 2          a     Blade Iron    et       1  I I  i      gt   i   i  gt   a l  I    I           A  Blade Mounting  Screws    12  42441 01   04 19 11    Hunter Fan Company                    Step 7 1  Detail     Use with grommet Blade Assembly    va Screws    Use without grommet       8    Completing Your Installation With a Light Fixture       Your Hunter fan comes with an integrated light fixture assembly     A WARNING  Use only the light fixture supplied with this fan model     8 1  To attach the light kit top housing  partially install two housing  assembly screws into the light kit mounting plate        8 2  Feed the upper plug connector through the center opening of the  light kit top housing     8 3  Align the keyhole slots in the housing with the housing assembly  screws    Light  8 4  Turn the light kit top housing counterclockwise until the housing   1P  ousing    assembly screws are firmly situated in the narrow ends of the       keyhole slots  Install the remaining screw into the housing  Tighten Steps 8 1   8 3                all three screws firmly     A CAUTION  Make sure the light kit top housing is securely  attached to the light
14. on the ceiling plate     A WARNING  The slots in the canopy must remain engaged while  swinging the canopy for alignment     Holding the canopy up with the screw holes aligned  partially  install two canopy screws into the holes opposite the ceiling plate  tabs       Partially install a canopy screw between the slots in the canopy     When all the holes are properly aligned  securely tighten all three  canopy screws       Verify that the tabs in the canopy are still in the grooves of the    hanger ball     Align the tabs on the trim ring opposite the grooves in the hanger  ball  Using both hands  push the canopy trim ring up to the top of  the canopy  The canopy trim ring will snap and lock into place   Note  Should you need to remove the trim ring  press firmly on  opposite sides of the trim ring directly above the groove in the  hanger ball  The tabs will flex out releasing the canopy trim ring                             Step 6 3       Canopy     gt     Canopy  Trim                           Canopy Screw    lI    42441 01   06 14 11    Hunter Fan Company                   7    Assembling the Blades    Hunter fans use several styles of fan blade irons  brackets that hold the  blade to the fan      7 1  Install the grommets into the blades by hand     7 2  Place each blade between a blade iron and medallion  Install three    blade screws to attach the medallion to the blade iron  Repeat for  all blades     7 3  Remove the blade mounting screws and metal shipping ring from  t
15. r holes in the box align  with the joist or support brace    4 3  Drill pilot holes no larger than the minor diameter of the wood screws  5 64      through the inner holes of the outlet box    4 4  Attach the outlet box directly to the support brace or joist with two  8 x 1 1 2     wood screws and washers  The bottom of the outlet box must be recessed a  minimum of 1 16    into the ceiling     Step 5   Prepare the Wiring    5 1  Make sure the circuit breakers to the fan supply line leads and associated wall  switch location are turned off   If you cannot lock the circuit breakers in the  off position  securely fasten a prominent warning device  such as a tag  to the  service panel     5 2  Thread the fan supply line through the outlet box so that the fan supply line  extends at least 6    beyond the box     5 3  Attach the fan supply line to the outlet box with an approved connector   available at any hardware store or electrical supply house     5 4  Make certain the wiring meets all national and local standards and ANSI NFPA  70     You have now successfully prepared your ceiling fan site  For instructions to install  your ceiling fan  go to your fan manual and continue with Section 2    Installing the  Ceiling Plate     4  42441 01     06 14 11   Hunter Fan Company                                  A CAUTION  All wiring must be in  accordance with national and local  electrical codes and ANSI NFPA 70  If  you are unfamiliar with wiring  use a    qualified electrician       
16. rely fasten a prominent warning device  such as a    tag  to the service panel     2 1  Drill two pilot holes into the wood support structure through the  outermost holes in the outlet box  The pilot holes should be 9 64     in diameter        For Angled Ceilings  Be sure to orient the ceiling plate so that the    two tabs are pointing toward the ceiling peak  For Angled Ceilings  Be sure to orient    the ceiling plate so that the two tabs    2 2  Your fan comes with four preinstalled noise isolators  Check to are pointing toward the ceiling peak     make sure all four isolators are in place and were not removed  during shipment        2 3  Place a flat washer on each of the two 3    wood screws     2 4  Thread the supply wires from the outlet box in the ceiling through  the hole in the center of the ceiling plate     2 5  Align the slotted holes in the ceiling plate with the pilot holes you  drilled in the wood support structure  For proper alignment use  slotted holes directly across from each other     Note  The isolators should be flush against the ceiling     2 6  Pass the screws through the slotted holes in the ceiling plate into  the pilot holes you drilled     Tighten the screws into the 9 64    pilot holes  do not use lubricants  on the screws  Do not over tighten     Flat Washer       3    Wood Steps 2 3   2 6  Screw             ements FEENUNUUEEEEEOUU NUN me       7  42441 01     06 14 11    Hunter Fan Company                3    Assembling and Hanging the Fan    A
17. sing    8 9  Turn the glass bowl clockwise until it  locks into place     42441 01   06 14 11    Hunter Fan Company    15           gt              Steps 8 8   8 9    9 1     9 2     9 3     9 4   9 5   9 6           9   Operating the Remote Control and Mounting the Holder    The remote transmitter has individual buttons for turning the    fan off and on and controlling the light and fan speed  Fanspeed    For best operation  start the fan by pressing high  then select High    your desired speed   Fan Speed  The light button turns the light on to full brightness  Push the Low    light button again to turn off the light   Press the OFF button to turn the fan off   When necessary  replace the battery with a 9 volt battery     You can mount the remote holder to any toggle switch plate  with the screws already in the switch plate  Or  you can simply  mount the remote holder on the wall              Steps 9 1   9 4                                      Step 9 6          Step 9 5             16  42441 01    06 14 11     Hunter Fan Company             Fan Speed  Medium    Fan Off    Fan Light       10   Operating and Cleaning Your Ceiling Fan       10 1  Restore power at the main electrical panel and turn on the wall  switch  The light kit should turn ON  To dim the light  hold the  light button down until you reach your desired brightness  Push  the light button again to turn off the light     Note  To turn on the light without the remote  turn off the wall  switch for 5 seconds  th
18. the opposite    position  Replace glass        17  42441 01     06 14 11   Hunter Fan Company                   11   Troubleshooting    Problem  Nothing happens  fan does not move    1  Turn power on  replace fuse  or reset breaker    2  Loosen canopy  check all connections according to the wiring the fan section    3  Check the plug connection in the switch housing    4  Push motor reversing switch firmly left or right to ensure that the switch is engaged   5  Pull the pull chain to ensure it is on    6  Remove the shipping bumpers     Problem  Noisy operation  1  Tighten the blade assembly screws and blade iron armature screws until snug   2  Check to see if the blade is cracked  If so  replace all the blades     Problem  Excessive wobbling  1  If your fan wobbles when operating  use the enclosed balancing kit and instructions to balance the fan   2  Tighten all blade iron screws   3  Turn power off  support fan very carefully  and check that the hanger ball is properly seated    Problem  Lights shut off suddenly  but fan is still operating    1  Check to make sure the wattage and type of the light bulbs that are installed meet the specifications on the  light socket     2  Turn the power to the fan off at the wall switch  Wait 5 minutes  then resume power to the fan   Problem  CFL bulbs flicker when controlled by a dimming remote or wall control    1  CFL light bulbs are not usually made for dimming  Replace the CFL bulbs with dimmable light bulbs  or install  the fan in a
19. ve the receiver transmitter for each fan set to a different code    so that the operation of one fan does not affect the operation of the  other fans     The DIP switches for the receiver are located on the flat surface of  the receiver  The DIP switches for the transmitter are in the battery  compartment        4 1  IMPORTANT  Before you change the DIP switch settings  make  sure the battery is not connected to the transmitter     Change the position of the DIP switches in the remote transmitter  and the receiver  Make sure that the DIP switches match in  the remote receiver and transmitter  If they don   t match  the  transmitter will not function  Transmitter DIP switches  4 2  There is a toggle switch beside the DIP switches on the transmitter   Move the toggle switch toward the side that reads    CFL    if you are  going to operate the fan with CFL bulbs  Move the switch to the     INC    side if you are going to use incandescent bulbs  Example DIP Switch Settings    4 3  Install the included 9 volt battery into the transmitter  Receiver 1 Receiver 2    A CAUTION  The remote control device complies with part 15 of the FCC rules   Changes or modifications not expressly approved by Hunter Fan Company could void  your authority to operate this equipment     ee l l ae DIP Switches DIP Switches  Operation is subject to the following two conditions  Set to 0111 Set to 0100  1  This device may not cause harmful interference   2  This device must accept any interference received
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
11 電子線の回折実験    コンクリート工学年次論文集 Vol.27  Samsung HT-TP12 Manual de utilizare  Catalogue  FandPLimitTool User`s Manual  Girls And Puberty - Department of Health  Einbauanleitung für Verstärker AMP 4.600 Bitte vor Beginn der  CDM6083 Ma-TUV # 0710-26  Configuring and Troubleshooting Windows Server® 2008    Copyright © All rights reserved. 