Home

Olympia Protect 9060

image

Contents

1. Registering Sensors Deregistering Sensors System Extension Changing the Batteries Remote Control Base Unit Regular Maintenance and Servicing Base Unit 26 Information on Disposal 34 27 Technical Data 2 yasal usnu el me 35 27 Base lnit un iuh us a qa EU UE E TUR 35 27 Remote Control Acetaat ente Tasa ott etie tu bottle 35 28 Technical Modifications cece eee 35 28 CE Mark Tan o RR MR Qe a m 36 OPERATING GB CE CY INSTRUCTIONS Introduction Warranty Dear Customer we are pleased that you have chosen this equipment In the case of a defect please return the device together with the receipt and original packing material to the point of sale OPERATING Introduction User Information The alarm system is a passive security product and has been conceived as a deterrent Additional measures are necessary to prevent and hinder burglary and theft You can obtain all the necessary information on this from your local police station Read the operating instruction manual thoroughly before connecting and starting the system for the first time The operating instruction manual will help prevent application errors and at the same time ensure you can ex ploit all the technical options provided by the wireless alarm
2. 4 Use the CA and buttons to select Standard or Activate 5 Confirm it by pressing C OK The main menu reappears in the display 6 Press to exit from the menu The table below indicates how the flood and smoke detectors are triggered according to the various settings E ol Phone call Alarm signal Phone call Alarm signal Disarmed At Home Silent mode Yes Yes Yes Yes Yes Yes Yes INSTRUCTIONS GB CE CY Page 25 Monitoring Functions Overview of Monitoring Functions Switching the Monitoring Functions On Off cg NOTE Before switching any functions on inform all the other people living in the residence regard ing the location and method of operation of the Yes with screening function wireless alarm system c NOTE The alarm period of the acoustic alarm is re stricted from a minimum of 1 minute to a max imum of 10 minutes depending on the config uration Monitoring Acoustic Internal GSM telephone function alarm signal dialling unit activated Silent mode I The wireless alarm system distinguishes between 4 types of alarm Emergency call Yes with handsfree function When Alarm mode is active and an alarm is triggered an acoustic Yes alarm signal is issued and the internal GSM telephone dialling unit is activated 2 f At Home mode When At Home mode is active and an alarm is triggered only an acoustic alarm signal is issued 3 amp Silent mode When Silent mode is active and an alarm is trigg
3. INSTRUCTIONS Page 9 Installation Installation Information on Selecting the Installation Location The base unit should be installed or positioned in a central location e g in the hallway of an apartment house in relation to the area to be monitored in order to keep all transmission paths as short as possible Place the base unit in a location where a properly installed power socket 230 V 50 Hz is available Ensure that the base unit can receive a sufficiently powerful signal from the mobile network Choose a location within the area being monitored to ensure that no intruders can approach the base unit and manipulate it The base unit and power adapter plug must not be used in damp rooms cellar bathroom etc or in the direct vicinity of sources of heat The base unit should not be installed setup on or in the direct vicin ity of large metallic objects or sources of electrical interference be cause this reduces the transmission range Examples of sources of interference Metallic objects Source of electrical interference Loudspeaker systems Concrete steel Unshielded electrical apparatus walls OPERATING BXEXC INSTRUCTIONS Preparing and C onnecting the Base Unit Installation 6 Insert three AAA alkaline batteries in the battery compartment pay attention
4. INSTRUCTIONS Menu Structure CA m Review Register Trigger Delay Arming Delay Flood amp Smoke Remote Key Entry Code OPERATING INSTRUCTIONS Open Sensor01 Voice Record Remote 1 Voice Record Search Open Sensor01 Voice Record Remote 1 Voice Record Duration Delay 0 240S Trigger Tone On Off Delay 0 240S Standard Activate Remote SOS Remote PANIC 1234 GDC CY Menu Structure Page 17 Menu Structure Key Tone Key Tone On Key Tone Off Contrast Contrast 1 5 Language Deutsch Espa ol Nederlands Dansk Portugu s English Fran ais Date Time 01 01 2010 00 00 Alarm period Time 1 10Min Check SIM SIM Service OPERATING GB GE CY INSTRUCTIONS Configuration General Information ce NOTE Before beginning to operate the base unit de activate the key lock function You need the 4 digit Entry Code to do this The default device specific Entry Code is provided in the battery compartment of the base unit The key lock is reactivated automatically when no buttons are pressed for a period of 10 seconds You can also activate the key lock function manu ally by pressing the button The SOS and Panic buttons are excluded from the key lock function and are always functional Operation The menu is opened by pressing the Menu button C A briefly Navigate through the menu using the arrow buttons A and vo Confirm selections and en
5. N Page 19 Configuration Setting the Date Time 1 Enter the device specific Entry Code Confirm it by pressing OK The menu is opened by pressing the Menu button A briefly Select the Date Time menu option Confirm it by pressing OK Display 01 01 2010 Use the keypad on the base unit to enter the day month and year Confirm it by pressing OK Display 00 00 Enter the time as hour and minute 8 Confirm it by pressing C OK The main menu reappears in the display 9 Close the menu by pressing the g sc button Q 0 N Oo Individual Outgoing Messages ce NOTE You can record an individual message of up to max 10 seconds for each sensor door window contact smoke detector The standard mes sage is replaced by your individual voice mes sage and played when the GSM telephone dial ling unit is activated Proceed as follows to record an individual messages for each respective sensor 1 Enter the device specific Entry Code Confirm it by pressing OK 2 The menu is opened by pressing the Menu button A briefly Select the Review menu option Confirm it by pressing C OK Select the respective sensor required by pressing the CA and buttons Confirm it by pressing C OK The first letter of the sensor selected flashes You can rename the sensor e g BalconyDoor KitchenWindow etc Confirm it by press ing Cok Text or numbers which
6. System Extesion Registering Sensors Up to 32 sensors can be registered on the wireless alarm system If you purchase optionally available sensors such as additional remote controls smoke detectors etc they must be registered manually Proceed as follows to register the sensors 1 Enter the device specific Entry Code Confirm it by pressing OK 2 Press the CA button to open the menu Use the CA and buttons to select the Register menu option Confirm it by pressing C OK 3 Search appears in the display 4 Activate the sensor to be registered To do this please refer to the description supplied with the sensor 5 Open Sensor01 or SmokeSensor01 for example appears in the display You can rename the sensor if necessary Confirm it by pressing C OK 6 Voice Record appears in the display Press esc to retain the standard message or press to record an individual message 7 Confirm it by pressing OK e NOTE If you do not confirm it by pressing the button recording is automatically ended after 10 seconds 8 Your individual message is played back The main menu reappears in the display OPERATING INSTRUCTIONS GDC GY Deregistering Sensors 1 Enter the device specific Entry Code Confirm it by pressing OK 2 Press the CA button Review appears in the display 3 Press the buttons CA and to select the sensor to be deregistered 4 Press the button Delete appears in
7. established with H 8 End the remote access via telephone the alarm system Remote appears in the facility base unit s display 1 Dial the mobile phone number of the SIM card installed in the alarm System u 6 Remote access to your alarm system is interrupted when you press 3 Enter your 4 digit Entry Code the button twice on your telephone 4 When you enter the code correctly you hear 2 short acoustic signals If you enter the code incorrectly 3 times the connection is interrupted 5 Use the keypad on your telephone to execute the following functions refer to table The monitoring functions are confirmed by a voice message OPERATING INSTRUCTIONS GB CE CY Page 29 Resetting the Factory Settings RESET Resetting the Factory Settings RESET Ee NOTE Please note that when carrying out a RESET all the user settings are deleted The registra tion of the sensors is retained After a RESET has been executed the 4 digit Entry Code is 1 2 3 4 Proceed as follows to reset the factory settings on the wireless alarm sys tem 1 Use a screwdriver to loosen the screw in the battery and connection socket compartment on the underside of the base unit 2 Press the RESET button The alarm system acknowledges a RESET by means of an acoustic signal 3 Close the battery and connection socket compartment and tighten the screw GDC GY OPERATING INSTRUCTIONS Registering and Deregistering Sensors
8. to a properly installed 230 V 50 Hz power socket The base unit is then ready to use OPERATING INSTRUCTIONS GB CE CY Page 13 Operating Elements and Indicators Operating Elements and Indicators The base unit is equipped with an SOS emergency call button for emer gency situations and a Panic button in the event of a direct threat The wireless remote control unit is provided with a button which can be con figured either as an Emergency Call or Panic button refer to Configuring the Wireless Remote Control Unit Pressing the Panic button triggers an immediate acoustic signal intended as a deterrent regardless of whether the alarm system is active or inactive The acoustic alarm can be switched off via the base unit or the wireless remote control refer to Disarmed Mode in Chapter Monitoring Functions Pressing the button button activates the internal GMS telephone dialling unit as long as phone numbers have been entered and stored beforehand refer to Configuring the internal GMS telephone dialling unit with OGM function The unit is activated regardless of whether the alarm System is armed or disarmed The emergency call number is dialled first then up to 10 stored phone numbers in succession A voice message requests the subscriber answering to press the 1 button on their phone The handsfree function is automatically activated on the base unit and enables communication between the caller and subscriber calle
9. to correct polarity Power socket N i s ON 7 If the alarm system is to be operated without the external antenna K d N option the antenna switch must be switched to the left and set to Ba 1 Int Antenna switch l t i SIM card p Power p es Antenna switch adapter plug 1 Use a screwdriver to loosen the screw in the battery and connection DN Oje Socket compartment on the underside of the base unit Remove the lid from the battery and connection socket compartment Q Q N right to lock it C Slide the SIM card holder to the left to unlock it A Pivot the holder up and insert the SIM card in the holder B Pivot the holder with the SIM card back and slide the holder to the 8 Connect the power adapter plug to the base unit 9 Replace the lid on the battery and connection socket compartment 10 Replace and tighten the screw r Lie e OPERATING INSTRUCTIONS GB CE CY Page 11 Installation Testing the GSM Telephone Dialling Unit Ee NOTE Test the GSM telephone dialling unit to ensure Q Q N N Oo that the alarm function is activated via the mo bile network Enter the device specific Entry Code Confirm it by pressing C OK The menu is opened by pressing the Men
10. Modifications This operating instruction manual serves purely for information purposes Its content is not part of any contract for sale All the data relates to nominal values The equipment and options de scribed may differ from country to country according to national require ments Page 35 CE Mark CE Mark The device fulfils the requirements stipulated in the EU Directive 1999 5 EC R amp TTE The CE Mark on the device confirms conformity GDC CY OPERATING INSTRUCTIONS Entry Code This is your individual device specific Entry Code If you want to change this predefined Entry Code please refer to Chapter Configuration in this operating instruction manual Keep this operating manual in a safe place away from the wireless alarm system Please note that the Copyright of this operating instruction manual is by Olympia and therefore must not be further copied published or sold in any form The information contained in the operating instruction manual is only intended for personal use C All rights reserved
11. OLYMPIA Protect 9XXX Series Wireless Alarm System CRA Instruction Manual 17 12 2012 en Olympia Business Systems Vertriebs GmbH Zum Kraftwerk 1 45527 Hattingen Contents Introduction 5 Operating Elements and Indicators 14 Warranty u such VR ERE eel ES EU 5 Function Assignment to Buttons Base Unit 14 User Information yuyu urus nu saus eee 5 Display ACONs y u y Han en 15 Disclaimer of Liability 5 Qverview or LEDS ono He eig 16 Intended Use 142 444 susssuasauskhuqanqhhkuahakanakujakuaquaq 5 Function Assignment to Buttons Remote Control 16 Product Features 6 Menu Structure 17 Scope of Delivery 6 Configuration 1 elec lel re xxr 19 Safety Information 7 General Information 19 Significance of the Symbols 7 Selecting the Language 22 22 nn eeeeeeeeeen ees 19 Important Safety Information 7 Entry Code 00 6 ccc enne 19 GSM Telephone Dialling Unit 8 S tting the Date Time uu 23 ee Here Hehe 20 Function of the GSM Telephone Dialling Unit 8 Individual Outgoing Messages 20 SIM G
12. ard 2242 24 eboney e uA TP PRU CVM ASIA 8 Petvating the GSM Internal Telephone Dialling Unit with OGM Function Unlocking the SIM Card 8 Saving an SOS Emergency Call Number 22 Reminder Function sssssseeeeee eee 9 Trigger Delay ass 23 Checking the Credit Status 9 Arming Del lesben nn ea RE eoe 23 Preventing me SIM Gard Being Locked J u u c reser 3 Alarm Period a ee es es elle 24 Installation 10 Key Tone OnO acces Leonie Ee er aes Atel Cau 24 Information on Selecting the Installation Location 10 Setting the Display Contrast 24 Preparing and Connecting the Base Unit 05 11 Remote Control s yaspa a sei eee 25 Testing the GSM Telephone Dialling Unit 12 Flood and Smoke Detectors 25 Positioning the Base Unit 12 Overview of Monitoring Functions 26 Wall Installation 2 52 13 OPERATING INSTRUCTIONS Page 3 Contents Switching the Monitoring Functions On Off Alarm Mode At Home Mode Silent Mode Disarmed Mode Panic Alarm Emergency Call SOS Remote Access Via Telephone Resetting the Factory Settings RESET
13. d Function Assignment to Buttons Base Unit Emergency Call button Activates the internal GSM telephone dialling unit Panic button Triggers an acoustic alarm signal Open the menu scroll up in the menu increase the loudspeaker volume in Handsfree mode G Open the Location Key function for phone numbers scroll down in the menu reduce the loudspeaker volume in Handsfree mode Disarmed mode The system is deactivated close the menu stop the countdown Silent mode The system is armed when the alarm is tripped the internal telephone dialling unit is activated delete digits and letters Alarm mode The system is activated on burglary the acoustic alarm signal and internal tele phone dialling unit are activated OPERATING INSTRUCTIONS Operating Elements and Indicators At Home mode The system is activated on burglary the acoustic alarm signal is issued 0 9 Digit keys On pressing the button gt 3 sec a 2 sec dialling pause is activated In Text mode Switch between upper and lower case o prennestr Space 1 lt gt RBCOAEAAAAG abc2 e g DEF3 def3 4 GHI4i il ghi4i ii 5 JKL5 jkl5 7 PQRS7R pqrs7R TUV8 0 tuv8 WXYZ9 wxyz9 OPERATING INSTRUCTIONS EIS Display Icons nnunnnnnn niri LL X COS Hh LI BBSBEEBREBRE GEELI Y l Mobile network Y l full signal Y weak sig
14. efective equipment must always be completed by au thorised service technicians Never touch the power adapter plug on the base unit with wet or damp hands If the power adapter plug shows signs of damage disconnect the fuse in the fuse box prior disconnecting the relevant plug from the power socket The wireless alarm system and packaging materials must not be used as toys by children NOTE This operating instruction manual contains important information on setting up and hand ling the equipment The manual must be en closed with the equipment if handed over to others Page 7 GSM Telephone Dialling Unit GSM Telephone Dialling Unit Function of the GSM Telephone Dialling Unit The GSM telephone dialling unit dual band 900 1800 MHz establishes a connection between the Protect 9XXX Series alarm system and mobile network It enables a telephone link to be set up without access to a land line SIM Card not included in equipment supplied In order to operate the GSM telephone dialling unit you need a SIM card from a mobile phone provider This is not included in the equipment sup plied ce NOTE The alarm system can also be operated without a SIM card connection However in the event of an alarm there is no alert via the mobile net work If you use a prepaid card pay attention to the following The card must be topped up at regular intervals Most prepaid cards must be used at a charge within a certai
15. eless alarm System into operation In such cases contact your sales outlet with your purchase receipt to hand or the OLYMPIA service centre ce NOTE Keep the packaging in a safe place to protect the equipment from damage should it need to be dispatched in future Ee NOTE This operating instruction manual relates to the base unit of the alarm system The sensors are described in separate manuals OPERATING INSTRUCTIONS Safety Information Significance of the Symbols WARNING CAUTION Q NOTE OPERATING INSTRUCTIONS Indicates potentially dangerous situations which could lead to fatal or severe personal injury if the information is ignored Indicates potentially dangerous situations which could lead to minor personal injury if the information is ignored Indicates potentially dangerous situations which could lead to property or environmental damage if the information is ignored Safety Information Important Safety Information Please observe the following safety information to ensure the wireless alarm system can be used safely and reliably EP GDC GY If you are uncertain or have any doubts about the functioning method of the equipment during assembly and installation contact a specialist In case of doubt do not complete assembly and install ation work yourself Never open the equipment Never use the device when it is wet or in the vicinity of a bathtub shower or such Repairs to d
16. en 0 and 240 seconds If one of the sensors is tripped the system must be switched to be dis armed for this period so that no alarm is triggered You can select whether an acoustic signal should be issued from the base unit during this period or not 1 Enter the device specific Entry Code Confirm it by pressing OK 2 The menu is opened by pressing the Menu button 4 briefly 3 Select the Trigger Delay menu option Confirm it by pressing 4 Select the Duration menu option Confirm it by pressing OK Use the A and buttons to set the required delay time 6 Confirm it by pressing the button The system returns to the previous menu level 7 Select the Trigger Tone menu option Confirm it by pressing C ex D 8 Use the CA and buttons to select Off or On 9 Confirm it by pressing the button The system returns to the previous menu level 10 Press Cresc to exit from the menu c1 OPERATING INSTRUCTIONS GDC CY Configuration Arming Delay You can set an activation delay between 0 and 240 seconds The alarm system is armed after this period has expired You must leave your apart ment house within this period through the door which will subsequently be monitored An acoustic signal is issued by the base unit every second for the period of the set delay time 1 Enter the device specific Entry Code Confirm it by pressing OK 2 The menu is opened by pressing the Menu button A brief
17. ered only the intern al GSM telephone dialling unit is activated A message requests the subscriber called to press the 1 button on their phone mobile The screening function is activated 4 Disarmed mode When Disarmed mode is set the alarm system is deactivated The monitoring functions are confirmed by a voice message No c NOTE When triggered the smoke detector always issues an acoustic alarm signal immediately regardless of the wireless alarm system The response of the base unit depends on the type of alarm and setting defined in the Flood amp Smoke menu option OPERATING BXEXC INSTRUCTIONS You can define the required type of alarm as follows using either the base unit or the remote control unit supplied cg NOTE If an outdoor siren is registered on the base unit the alarm can be stopped by the remote control unit after 15 seconds at the earliest Alarm Mode ce NOTE You should activate Alarm mode when you leave your apartment or house Before doing So check that all the doors and windows provided with a door window contact are closed Base unit 1 Enter the device specific Entry Code Confirm it by pressing OK 2 Press the button Remote control 1 Press the 4 button OPERATING INSTRUCTIONS GDC CY Monitoring Functions At Home Mode Ee NOTE During the night when you are asleep you should activate At Home mode Before doing so check that all the doors and window
18. have been entered can be deleted by press ing the button Voice Record appears in the display Confirm it by pressing Speak your individual voice message for the selected sensor into the unit e g BalconyDoor Press the button to confirm the message and end recording eS NOTE If you do not confirm it by pressing the button recording is automatically ended after 10 seconds 10 Your individual voice message is played back The main menu re appears in the display 11 Close the menu by pressing the 8 sc button OPERATING GB CE CY INSTRUCTIONS Activating the GSM Internal Telephone Dialling Unit with OGM Function Ee NOTE A SIM card must be installed in order to use the GSM telephone dialling unit The internal telephone dialling unit is deactivated if no telephone numbers have been entered and saved You can enter up to 10 individual telephone or mobile phone numbers of contact persons such as relatives friends or neighbours In the event of an alarm the internal GSM telephone dialling unit dials these phone num bers automatically in the sequence they were entered beginning with memory location 0 and communicates the status via the voice messages assigned to the respective sensors In the case of an engaged signal or no connection is possible the next phone number is automatically dialled A total of three dialling cycles are completed The internal GMS telephone dialling unit is deactivated
19. le phone provider Press to end the call You can request the credit status at any time by using the menu aR WD N Oo Enter the device specific Entry Code Confirm it by pressing C OK The menu is opened by pressing the Menu button a briefly Select the Check SIM menu option Confirm it by pressing OK SIM Service appears in the display Enter the service number of the mobile phone provider Confirm it by pressing C OK The service number is dialled Follow the instructions from the mobile phone provider Press to end the call GSM Telephone Dialling Unit Preventing the SIM Card Being Locked Most prepaid cards must be used at a charge within a certain period of time otherwise they are blocked You can use the function requesting the credit status to make a call liable for costs Q NOTE Q Q N o Contact your mobile phone provider for details regarding time limits within which prepaid cards must be used Enter the device specific Entry Code Confirm it by pressing C OK The menu is opened by pressing the Menu button A briefly Select the Check SIM menu option Confirm it by pressing C OK SIM Service appears in the display Enter the number of your conventional phone or mobile phone Confirm it by pressing C OK The number is dialled Take the call on your conventional phone or mobile phone Press to end the call OPERATING e IE Co
20. ly 3 Select the Arming Delay menu option Confirm it by pressing C ok 4 Use the A and buttons to set the required delay time 5 Confirm it by pressing C OK The main menu reappears in the display 6 Press to exit from the menu Page 23 Configuration Alarm Period Key Tone On Off The base unit is equipped with an integrated siren The duration of the It is possible to switch the key tone feature for the base unit on and off acoustic alarm can be selected between a minimum of 1 minute to a max imum of 10 minutes The alarm period is preset to 3 minutes an alarm 1 Enter the device specific Entry Code Confirm it by pressing C ex gt period up to 3 minutes is permitted in Germany 2 The menu is opened by pressing the Menu button CA briefly m f 3 Select the Key Tone menu option Confirm it by pressing OK 1 Enter the device specific Entry Code Confirm it by pressing OK 4 Use the CA and buttons to select the Key Tone On or 2 The menu is opened by pressing the Menu button A briefly Key Tone Off function 3 Select the Alarm period menu option Confirm it by pressing 5 Confirm it by pressing C OK _ The main menu reappears in the Cok D display 4 Use the A and buttons to set the required alarm period 6 Press to exit from the menu 5 Confirm it by pressing C OK The main menu reappears in the display f Setting the Display Contrast 6 Press g esc to exit from the menu The display con
21. n period of time otherwise they are blocked Contact your mobile phone provider for details regarding deadlines GDC GY Unlocking the SIM Card SIM cards are normally locked against unauthorised use by means of a 4 digit PIN When the SIM card is used for the first time it must be unlocked 1 If the SIM card is locked against use by a PIN SIM Card PIN ap pears in the display 2 Enter the PIN received together with the SIM card 3 When the PIN has been entered correctly Search appears in the display The PIN is then permanently deactivated If you insert the SIM card again or connect the base unit again the PIN need not be entered f you enter the PIN incorrectly Enter again appears in the display f you enter the PIN incorrectly 3 times SIM Locked appears in the display In this case contact your mobile phone provider to unlock the SIM card fthe SIM card inserted is not a GSM card SIM Error appears in the display OPERATING INSTRUCTIONS Reminder Function Check SIM appears in the display on 31st March 30th June 30th September and 31st December Checking the Credit Status 4 When the Check SIM reminder message appears enter the device specific Entry Code Confirm it by pressing OK SIM Service appears in the display Enter the service number of the mobile phone provider Confirm it by pressing C OK The service number is dialled Follow the instructions from the mobi
22. nal Y nosignal M Silent mode If an alarm is triggered no acoustic alarm is issued internal GSM tele phone dialling unit is activated Alarm mode If an alarm is triggered an acoustic alarm is issued internal GSM tele phone dialling unit is activated At Home Mode If an alarm is triggered an acoustic alarm is issued Emergency call Internal GSM telephone dialling unit is activated QO Time delay Time delay is activated amp Key lock Key lock is activated B Internal GSM Connection is being made telephone dialling unit activated Recording mode Voice message is being recorded Page 15 Operating Elements and Indicators Memory location Indicates the memory location of the display phone number Function Assignment to Buttons Remote Control amp Battery indicator Battery capacity of base unit is low Overview of LEDs With power supply Without power supply TopLED Bottom LED TopLED Bottom LED red yellow red yellow ff ff At Home mode Lights up Lights up Lights up inactive mode Lights up Emergency call or panic function can be optionally con figured on the base unit Alarm mode On burglary an acoustic alarm signal is issued and internal telephone dialling unit is activated Deactivate key lock on base unit Stop alarm signal Switch alarm system inactive Ee Silent mode activated on pressing the Alarm and At Home mode buttons simultaneously OPERATING GB CE CY
23. ompartment 6 Replace and tighten the screw wo Base Unit The M icon in the display indicates a low battery capacity in the base unit Change the batteries 1 Use a screwdriver to loosen the screw in the battery and connection socket compartment on the underside of the base unit 2 Remove the lid from the battery and connection socket compartment 3 Remove the batteries contained 4 Insert three new AAA alkaline batteries in the battery compartment pay attention to correct polarity 5 Replace the lid on the battery and connection socket compartment 6 Replace and tighten the screw OPERATING INSTRUCTIONS Regular Maintenance and Servicing Regular Maintenance and Servicing Base Unit 1 Disconnect the base unit from the power outlet before cleaning it 2 Clean the surface of the housing with a soft lint free cloth Never use any chemicals or scouring agents cg NOTE Never immerse the equipment in water OPERATING INSTRUCTIONS GB CE CY Page 33 Information on Disposal Information on Disposal The implementation of European law in national laws and direct ives obliges you to dispose of consumable goods appropriately This serves to protect both persons and the environment The adjacent symbol indicates that electrical and electronic appar atus and batteries no longer required must be disposed of sep arate from normal household waste Old or unwanted devices must be disposed of at collection wa
24. reening and handsfree functions Transmit function to activate outdoor sirens etc ntegrated GSM telephone dialling unit with outgoing message for alarm messages via the mobile network Upto 10 alarm call numbers and 1 emergency call number SOS can be stored Messages for alarm calls can be set up individually for each re spective sensor up to max 10 seconds long Automatic dialling of the next number when the number called is engaged Handsfree function on the base unit in the case of an SOS Telephone silent alarm siren alarm can be set individually or com bined Large LC display 1 numeric line in 7 segments for 24 characters 1 alphanumeric line in 5x7 dot matrix for 13 characters 11 icons as status indicators Display lighting in yellow and blue Warning in the event of a low battery charge status base unit and all registered sensors Power failure backup in the base unit Base unit has a remote control facility Upgradable for operation with max 32 sensors Simple integration of new sensors smoke detectors Plug and Play Page 6 GDC GY Scope of Delivery Base unit 1 Power adapter plug 1 Remote control 1 Batteries 3x alkaline AAA 1x lithium CR2430 3 V Assembly material Screws dowels adhesive tape Operating instructions 1 Please check the contents of the package carefully If anything is missing or has been damaged during transport DO NOT put the wir
25. s automatically activated when phone numbers have been stored The emer gency call number is dialled first then up to 10 stored phone numbers in succession A message requests the subscriber called to press the 1 button on their phone mobile The handsfree function is automatically activ ated and enables communication between the caller and subscriber called There are three ways to end the SOS function a Enter your 4 digit Entry Code on the base unit and confirm it by pressing the button b Press the button on the remote control c The subscriber called takes the call executes a function with in 24 seconds refer to Activating the Internal Telephone Dialling Unit with OGM Function and then ends the call OPERATING INSTRUCTIONS Remote Access Via Telephone Remote Access Via Telephone The wireless alarm system can be operated by remote access using a telephone You can use a telephone to activate or deactivate the alarm System and switch the handsfree and screening functions on Activate the handsfree function Activate the screening function in the room Activate Alarm mode Proceed as follows to operate your alarm system by remote access using a telephone Activate At Home mode Activate Silent mode 2 Wait until the alarm system takes the call following the eighth ring Activate Disarmed mode You will hear a long acoustic signal End the handsfree or screening function ee NOTE As soon as a connection is
26. s are closed Base unit 1 Enter the device specific Entry Code Confirm it by pressing OK 2 Press the button Remote control 1 Press the button Silent Mode cg NOTE When you leave your apartment or house you can activate Silent mode instead of Alarm mode Before doing so check that all the doors and windows are closed Base unit 1 Enter the device specific Entry Code Confirm it by pressing OK 2 Press the button Remote control 1 Press the 4 and 9 buttons simultaneously Page 27 Monitoring Functions Disarmed Mode Ee NOTE When alarm system is disarmed you can move freely within the living quarters without trigger ing any alarms Base unit 1 Enter the device specific Entry Code Confirm it by pressing C OK Remote control 1 Press the button Panic Alarm You can activate a panic alarm as a deterrent by pressing the button on the base unit or the button on the remote control unit de pending on the configuration The panic alarm is triggered immediately without any delay To switch off the panic alarm enter your 4 digit Entry Code on the base unit Confirm it by pressing C OK Or you can press the button on the remote control GDC GY Emergency Call SOS You can trigger the SOS emergency call function by pressing the button on the base unit or the button on the remote control unit de pending on the configuration The internal GSM telephone dialling unit i
27. sa points provided by public waste authorities Batteries and power packs must be disposed of at shops ge which sell batteries or collection points which provide the corres ponding containers us Packaging materials must be disposed of according to local regulations OPERATING GB CE CY INSTRUCTIONS Technical Data The wireless alarm systems in the Protect 9XXX Series operate within the frequency band specially reserved for security technology in the 868 MHz frequency range This ensures that interference to the wireless alarm sys tem by other consumer products such as baby monitors is ruled out However it cannot be ruled out that the radio transmission suffers intermit tent or continuous interference due to defective components of other elec trical or electronic products such as ventilators and antenna amplifiers In addition radio transmission can be subject to interference from external sources with wilful intent Base Unit Weight 228 g without batteries Dimensions WxHxD 172 x 105 x 31 mm Frequency 868 MHz Battery 3 AAA alkaline Power adapter plug 6Vac 1A Number of sensors Max 32 OPERATING INSTRUCTIONS GDC GY Technical Data Remote Control Weight csset Rae 24g Dimensions WxHxD 40 x 60 x 14 5 mm Frequency 868 MHz Battery Lithium CR2430 3 V Technical
28. system to the full Disclaimer of Liability We cannot guarantee that the information which relates to the technical properties of the product or to the product itself contained in this document is correct The product and its accessories described in this document are subject to constant improvement and further development For this reason we reserve the right to modify components accessories technical specific ations and related documentation of the product described herein at any time without notice Intended Use The wireless alarm systems from the Protect 9XXX Series enable you to monitor rooms and buildings as long as the local conditions are such that they enable a reliable transmission link to the sensors e g door window contact smoke detector In addition all doors and windows must be equipped with door window contacts A condition for complying with the intended use is that the equipment is installed correctly and the information in this operating instruction manual is observed and maintained Any other use is considered unintended use Unauthorised modifications or reconstructions not described in this operating instruction manual are not permitted and could cause the product to be damaged Furthermore risks through short circuits fire electric shock etc cannot be ruled out INSTRUCTIONS GB CE CY Page 5 Product Features Scope of Delivery Product Features Wireless alarm system with emergency call panic sc
29. ter the name associated with the phone number Confirm it by pressing OK 6 Press to exit from the menu Page 21 Configuration After having entered phone numbers ensure that they are correct in re spect of the alarm calls You can do this by triggering a silent alarm The telephone numbers you have entered are dialled in succession in the pro grammed sequence 1 Enter the device specific Entry Code Confirm it by pressing OK 2 On pressing the key Silent mode is activated Silent mode is indicated in the display by the amp icon after the selected arming delay has expired 3 Now trip the silent alarm on any of the door window contacts e g open door window Ee NOTE When Silent mode is active there is no acous tic alarm signal The display lights up yellow and indicates which sensor has been triggered The internal GSM telephone dialling unit is ac tivated after the trigger delay has expired The subscriber called takes the call and the individual message recorded for the sensor triggered is played The subscriber called is also requested to press digit key 1 on their telephone The screening function is activated This function enables the subscriber to screen the room in which the base unit is located f the subscriber called does not initiate a function within 24 seconds the next phone number is automatically dialled Silent mode is deactivated by pressing the button on the re mote con
30. the display 5 Confirm it by pressing C OK Empty appears in the display 6 Press the B sc button twice to exit from the menu System Extension You can order accessories and options for the wireless alarm system via the following web site www olympia vertrieb de Y Products Y Security Products Wireless Alarm Systems Page 31 Changing the Batteries Changing the Batteries If the battery charge of the sensors is low or practically empty one of the following status messages appear in the display Battery capacity low 1 bAtt Lo appears in the display The sensor in question e g Open Sensor01 is indicated 2 If you activate the alarm system 5 successive short acoustic signals are issued cg NOTE Change the batteries Battery charge empty 1 bAtt off appears in the display The sensor affected e g Open Sen sor01 is indicated 2 If you activate the alarm system 5 successive short acoustic signals are issued Q NOTE Change the batteries A connection between the sensor and base unit is no longer guaran teed GDC GY Remote Control 1 Use a precision screwdriver to loosen the screw in the battery com partment on the underside of the remote control unit 2 Remove the cover of the battery compartment Remove the battery contained 4 Insert a new CR2430 3 V lithium battery in the battery compartment ensure correct polarity 5 Replace the cover on the battery c
31. trast can be adjusted to one of five different settings 1 Enter the device specific Entry Code Confirm it by pressing C OK 2 The menu is opened by pressing the Menu button A briefly 3 Select the Contrast menu option Confirm it by pressing C OK 4 Use the CA and buttons to adjust the contrast according to your needs 5 Confirm it by pressing C OK The main menu reappears in the display 6 Press to exit from the menu OPERATING BXEXC INSTRUCTIONS Remote Control The button on the remote control can be configured as an SOS emer gency call or Panic button via the base unit Proceed as follows to configure the button Enter the device specific Entry Code Confirm it by pressing C OK The menu is opened by pressing the Menu button a briefly Select the Remote Key menu option Confirm it by pressing C OK Use the A and buttons to select the Remote SOS or Remote PANIC function 5 Confirm it by pressing C OK The main menu reappears in the display 6 Press B sc to exit from the menu O N OPERATING Configuration Flood and Smoke Detectors You can set up the base unit so that flood and smoke detectors trigger an alarm when the base unit is disarmed 1 Enter the device specific Entry Code Confirm it by pressing OK 2 The menu is opened by pressing the Menu button A briefly 3 Select the Flood amp Smoke menu option Confirm it by pressing C ok
32. tries by pressing the button If values are set in certain menus they are accepted and saved Text or numbers which have been entered can be corrected by pressing the button Press the esc button briefly to move one menu level back f no button is pressed for a period of 10 seconds the menu is auto matically closed and the key lock activated OPERATING INSTRUCTIONS GDC CY Configuration Selecting the Language There is a range of languages available for selection Enter the device specific Entry Code Confirm it by pressing OK The menu is opened by pressing the Menu button A briefly Select the Language menu option Confirm it by pressing C OK Select the language required by pressing the Ca and buttons 5 Confirm it by pressing C OK The main menu reappears in the display 6 Close the menu by pressing the B Esc button Entry Code Proceed as follows to change the Entry Code 1 Enter the device specific Entry Code Confirm it by pressing OK 2 The menu is opened by pressing the Menu button briefly 3 Select the Entry Code menu option Confirm it by pressing The default Entry Code appears in the display The first digit flashes Enter the 4 digit Entry Code 4 Note your individual Entry Code down and keep it in a safe place 5 Confirm it by pressing C OK The main menu reappears in the display 6 Close the menu by pressing the Messe button OQ
33. trol entering your Entry Code on the base unit and con firming by pressing the button or when the subscriber called ends the call Saving an SOS Emergency Call Number You can save an SOS emergency call number which is subsequently called first by pressing the button on the base unit or depending on the configuration the button on the remote control Following this number the other phone numbers stored maximally 10 are called in suc cession refer to Activating the Internal Telephone Dialling Unit with OGM Function Save the SOS number as follows Ee NOTE Unjustified requests for police fire and rescue services are liable for costs 1 Enter the device specific Entry Code Confirm it by pressing OK 2 Press the button Location Key appears in the display 3 Press the button as the selected memory location If you have not yet stored a phone number Empty appears as information in the display Confirm it by pressing OK 4 Enter the phone number including the access code Confirm it by pressing C OK 5 Enter the name associated with the phone number Confirm it by pressing OK 6 Press to exit from the menu OPERATING BXEXC INSTRUCTIONS Trigger Delay The alarm is triggered after a delay so that if someone enters through the main door they can disarm the alarm system before the acoustic alarm signals and internal GSM telephone dialling unit are activated You can set a trigger delay betwe
34. u button A briefly Select the Check SIM menu option Confirm it by pressing OK SIM Service appears in the display Enter the number of your conventional phone or mobile phone Confirm it by pressing C OK The number is dialled Take the call on your conventional phone or mobile phone Press to end the call Positioning the Base Unit It is possible to setup the device in a user friendly inclined position on a table or desk To do this insert the two legs 1 supplied in the recesses for the wall installation bracket 2 on the rear of the base unit 1 R e 2 Al mo OPERATING GBAE EN INSTRUCTIONS Installation Wall Installation After having found a suitable location for the base unit you can begin with the installation WARNING Risk of fatal injury through electric shock or gas explosion Pay attention that you do not damage electric cables or gas pipes Ee NOTE Also pay attention to water pipes 1 At the installation location insert two screws in the wall 100 mm apart and aligned horizontally It may be necessary to drill the holes first and then insert dowels in which to tighten the screws depending on the properties of the wall 2 Screw the screws in the wall using a screwdriver until there is approx 3 mm clearance from the bottom edge of the screw head to the wall 3 Hook the base unit over the screws 4 Connect the power adapter plug
35. when a subscriber called answers the call made and presses the numeric key 1 on his tele phone or 3 dialling cycles have been completed ce NOTE Save as many phone numbers as possible This increases the probability of reaching a contact person in the event an alarm is triggered If for example you only save two phone numbers and both are engaged when the alarm call is sent the dialling cycle soon comes to an end ceo NOTE Do not forget to inform the contact persons that they will be called by your alarm system automatically if an alarm is triggered and agree on a sequence of actions if the alarm is triggered OPERATING INSTRUCTIONS GDC GY Configuration Memory locations 0 9 buttons C O to 9wwz are available to enter up to 10 phone numbers Each phone number can be composed of up to 24 characters digits In addition a name with up to 13 characters letters can be assigned to each phone number Ee NOTE Unjustified requests for police fire and rescue services are liable for costs Save the phone numbers as follows 1 Enter the device specific Entry Code Confirm it by pressing OK 2 Press the button Location Key appears in the display 3 Select a memory location button C O 9wxz If you have not yet stored a phone number Empty appears as information in the display Confirm it by pressing OK 4 Enter the phone number including the access code Confirm it by pressing OK 5 En

Download Pdf Manuals

image

Related Search

Related Contents

JL Audio FS110-W5 User's Manual  Dataflex Cable Loop Ties  Getting Started-- Multi  Edital 2014_06297(7419) MT MS RO Vistoria  VX40 - Kello-Optiikka Lappalainen  5 - Hangar-9    BROEN BALLOMAX: user manual  Samsung 650MP 用户手册  Samsung Omnia W Lietotāja rokasgrāmata  

Copyright © All rights reserved.
Failed to retrieve file