Lapara LA-ITR-1500-LCD uninterruptible power supply (UPS)
Contents
1. 120 VAC or 208 220 230 240 VAC 3 before battery alarm 50 Hz or 60 Hz 1 Hz 8 max 100 linear load 15 max 100 non linear load before alarm Typical 2 6 ms 10ms max Waveform Batt Mode Pure Sine Wave EFFICIENCY Buck amp Boost Mode 90 90 90 BATTERY Battery Type amp 12 V 7 Ah x2 12 V 9 Ahx2 12 V 7 Ah x4 12 V 9 Ah x4 12 V 7 Ah x6 12 V 9 Ah x6 Standard Sule Model Charging Voltage 27 4 VDC 1 54 8 VDC 1 82 1 VDC 4 1 Recharge Time 4 hours recover to 90 capacity Long run Charging Current 4 A 8A 4 AI8A 4 AIBA Model N A N A N A eae Charging Voltage 27 4 VDC 1 54 8 VDC 1 82 1 VDC 1 PROTECTION Full Protection Overload short discharge and overcharge protection ALARM Battery Mode Sounding every 10 seconds Low Battery Sounding every second Overload Sounding every 0 5 second Battery Replacement Alarm Sounding every second Fault Continuously sounding PHYSICAL Dimension Standard DXWXH mm 380 x 438 x 88 480 x 438 x 88 600 x 438 x 88 Net Weight kg 14 23 21 08 30 65 32 24 Dimension 600 x 438 x oe DXWXH mm sa 380 x 438 x 88 a 480 x 438 x 88 NA 38 ret Net eit o ENVIRONMENT Operating Humidity 0 90 RH 0 40 C non condensing Noise Level Less than 45dB MANAGEMENT Smart RS 232 USB Supports Windows 2000 2003 XP Vista 2008 Windows 7 Linux Unix and MAC Model as O Optional SNMP Power management from SNMP manager and web browser Derate capacity to 80 of capa
2. 4 programs to ttt set up output voltage setting Q amp Ss programmable outlets enable disable __ 1 programmable outlets setting LCD display direction and exit For 208 220 230 240 VAC models you may choose the following output voltage 208 presents output voltage is 208Vac 220 presents output voltage is 220Vac 230 presents output voltage is 230Vac 240 presents output voltage is 240Vac For 110 120 VAC models you may choose the following output voltage 110 presents output voltage is 110Vac 120 presents output voltage is 120Vac ENA Programmable outlets enable DIS Programmable outlets disable LA ITR LCD lapara 03 Programmable outlets setting Setting the backup time limits in minutes from 0 999 for programmable outlets that connect to non critical devices on battery mode RAC the LCD display is horizontal TOE the LCD display is vertical 00 Exit setting Steps for setting programmable outlet Step 1 Before entering setting mode the UPS should be in Stand by mode off charging and make sure the battery is connected The LCD display is shown as right Step 2 Press and hold the Selection button for 5 seconds to enter Setting mode Step 3 Press the Up button ON MUTE to switch to 02 of program list Then press Enter button to enter value setting of parameter 2 Press the Up button to change the value to ENA to enable the programmable outlet fu
3. Do not disconnect the mains cable on the UPS system or the building wiring outlet shockproof socket outlet during operations since this would cancel the protective earthing of the UPS system and of all connected loads The UPS system features its own internal current source batteries The UPS output sockets or output terminals block may be electrically live even if the UPS system is not connected to the building wiring outlet In order to fully disconnect the UPS system first press the OFF Enter button to disconnect the mains Prevent no fluids or other foreign objects from inside of the UPS system ee SE LA ITR LCD lapara 1 5 Maintenance Service and Faults The UPS system operates with hazardous voltages Repairs may be carried out only by qualified maintenance personnel Caution risk of electric shock Even after the unit is disconnected from the mains building wiring outlet components inside the UPS system are still connected to the battery and electrically live and dangerous Before carrying out any kind of service and or maintenance disconnect the batteries and verify that no current is present and no hazardous voltage exists in the terminals of high capability capacitor such as BUS capacitors Only persons are adequately familiar with batteries and with the required precautionary measures may replace batteries and supervise operations Unauthorized persons must be kept well away from the batteries Caution risk of electri
4. NOTICE Please assemble battery kit first before installing it inside of UPS Please select correct battery kit procedure below to assemble it 2 battery kit Step 1 Remove adhesive tapes Step 2 Connect all battery terminals by following below chart Step 3 Put assembled battery packs on one Step 4 Cover the other side of plastic shell as side of plastic shells below chart Then battery kit is assembly well 4 battery kit Step 1 Remove adhesive tapes Step 2 Connect all battery terminals by following below chart Tapes Step 3 Put assembled battery packs on one Step 4 Cover the other side of plastic shell as side of plastic shells below chart Then battery kit is assembly well LA ITR LCD lapara 6 battery kit Step 1 Remove adhesive tapes Step 2 Connect all battery terminals by following below chart Step 3 Put assembled battery packs on one Step 4 Cover the other side of plastic shell as side of plastic shells below chart Then battery kit is assembly well eee S LA ITR LCD lapara 3 Operations 3 1 Button Operation ON MUTE Button OFF ENTER Button SELECT Button gt gt onmure f secect fforrenter Loa MO O TS O oS E E Turn on the UPS Press and hold ON Mute button for at least 2 seconds to turn on the UPS Mute the alarm After the UPS is turned on in battery mode press and hold this button for at least 5 seconds to disable or enable the alarm system B
5. sounding Battery backup time is shorter Batteries are not fully Charge the batteries for at than nominal value charged least 5 hours and then check capacity If the problem still persists consult your dealer Batteries defect Contact your dealer to replace the battery The icon and the warning code FA flashing on LCD Fan is locked or not Check fans and notify working dealer display and alarm is sounding every second 17 eee LA ITR LCD lapara 5 Storage and Maintenance 5 1 Operation The UPS system contains no user serviceable parts If the battery service life 3 5 years at 25 C ambient temperature has been exceeded the batteries must be replaced In this case please contact your dealer 2A Be sure to deliver the spent battery to a recycling facility or ship it to your dealer in the replacement battery packing material 5 2 Storage Before storing charge the UPS 5 hours Store the UPS covered and upright in a cool dry location During storage recharge the battery in accordance with the following table Storage Temperature Recharge Frequency Charging Duration 25 C 40 C Every 3 months 1 2 hours 40 C 45 C Every 2 months 18 ee SE LA ITR LCD alapar 6 Specifications LA ITR 800 LA ITR 1100 LA ITR 1500 LA ITR 2000 LA ITR 2500 LA ITR 3000 LCD LCD LCD LCD LCD LCD 640 W 880 W 1200 W 1600 W 2000 W 2400 W INPUT 81 145 VAC or 162 290 VAC 60 50 Hz auto sensing OUTPUT 110
6. A ITR LCD lapara Operating mode LCD display Standby mode UPS is powered off and no output supply power but still can charge batteries 3 7 Faults Reference Code Bus startfail 0 Busover 0 0 Battery voltage too high 02 j a 12 1 2 3 Inverter soft start fail 11 Over temperature 12 13 nverter voltage high x Overload 48 Inverter voltage Low 13 x 3 8 Warning Indicator Icon flashing Alarm Low Battery ee we Sounding every second Sounding every second erchace aa Stewiing faut SEZ Sounding every second O Poeme EP ZX Sounding every second Over temperature LWN Sounding every second Charger failure Sounding every second Battery Fault of Sounding every second 15 LA ITR LCD lapara 4 Troubleshooting If the UPS system does not operate correctly please solve the problem by using the table below Symptom No indication and alarm even The AC input power is not Check if input power cord though the mains is normal connected well firmly connected to the mains The AC input is connected Plug AC input power cord to the UPS output to AC input correctly EPO function is activated Set the circuit in close The icon_ and the warning position to disable EPO code EP flashing on LCD function display and alarm is sounding every second and SF flashing on LCD display and alarm is sounding every second The ex
7. LA ITR UPS User Manual idpofd LA ITR 800 LCD LA ITR 1500 LCD LA ITR 2000 LCD LA ITR 2500 LCD LA ITR 3000 LCD Line Interactive Pure Sine Wave UPS Table of Contents 1 Important Safety Warning ccccceeeeesseeeeeeeeeeeeseeeeeeennnaes 2 1 1 Transportation 2 1 2 Preparation 2 1 3 Installation 2 1 4 Operation 2 1 5 Maintenance Service And Faults 3 2 Installation And SOU wciiec saan cect case ret rec netawaweetueeeeeessestane 4 2 1 Rear Panel View 4 2 2 Install The UPS 4 2 3 Setup The UPS 5 2 4 Battery Replacement 2 5 Battery Kit Assembly Option 8 S OPETIUONS eaea EE E EEEE REEE REEERE N 10 3 1 Button Operation 10 3 2 LCD Panel 10 3 3 Audible Alarm 11 3 4 LCD Display Wordings Index 12 3 5 UPS Setting 12 3 6 Operating Mode Description 14 3 7 Faults Reference Code 15 3 8 Warning Indicator 15 A TrOU DISSNOOUNO esiri anen ee E EEEE 16 5 Storage And Maintenance ccccceeeeeeesceeeeeeennesceeeeeeennaaes 18 6 SOCCINICAUIOING sicun ss cxesaceeccoeacssnecesueeseee sec tneee nese eecieeseneeeestcuced ae 19 ce LA ITR LCD lapara 1 Important Safety Warning Please comply with all warnings and operating instructions in this manual strictly Save this manual properly and read carefully the following instructions before installing the unit Do not operate this unit before reading through all safety information and operating instructions carefully 1 1 Transportation
8. Please transport the UPS system only in the original package to protect against shock and impact 1 2 Preparation Condensation may occur if the UPS system is moved directly from cold to warm environment The UPS system must be absolutely dry before being installed Please allow at least two hours for the UPS system to acclimate the environment Do not install the UPS system near water or in moist environments Do not install the UPS system where it would be exposed to direct sunlight or near heater Do not block ventilation holes in the UPS housing 1 3 Installation Do not connect appliances or devices which would overload the UPS system e g laser printers to the UPS output sockets Place cables in such a way that no one can step on or trip over them Do not connect domestic appliances such as hair dryers to UPS output sockets The UPS can be operated by any individuals with no previous experience Connect the UPS system only to an earthed shockproof outlet that must be easily accessible and close to the UPS system Please use only VDE tested CE marked mains cable e g the mains cable of your computer to connect the UPS system to the building wiring outlet shockproof outlet Please use only VDE tested CE marked power cables to connect the loads to the UPS system When installing the equipment it should ensure that the sum of the leakage current of the UPS and the connected devices does not exceed 3 5mA 1 4 Operation
9. bility during this initial charge period Step 8 Install software For optimal computer system protection install UPS monitoring software to fully configure UPS shutdown Please follow steps below to download and install monitoring software 1 Go to the website http www power software download com 2 Click ViewPower software icon and then choose your required OS to download the software 3 Follow the on screen instructions to install the software 4 When your computer restarts the monitoring software will appear as an orange plug icon located in the system tray near the clock 6 eee S LA ITR LCD lapara 2 4 Battery Replacement NOTICE This UPS is equipped with internal batteries and user can replace the batteries without shutting down the UPS or connected loads hot swappable battery design Replacement is a safe procedure isolated from electrical hazards CAUTION Consider all warnings cautions and notes before replacing batteries Note Upon battery disconnection equipment is not protected from power outages m I Pull out the battery box by removing two screws on the front panel Step 6 ES Remove the top cover of battery After replacing the batteries Re connect the battery wires box and replace the inside put the battery box back to batteries original location and screw it tightly Step 7 Put the front panel back to the unit eee S LA ITR LCD lapara 2 5 Battery Kit Assembly option
10. c shock The battery circuit is not isolated from the input voltage Hazardous voltages may occur between the battery terminals and the ground Before touching please verify that no voltage is present Batteries may cause electric shock and have a high short circuit current Please take the precautionary measures specified below and any other measures necessary when working with batteries v remove wristwatches rings and other metal objects v Use only tools with insulated grips and handles When changing batteries install the same number and same type of batteries Do not attempt to dispose of batteries by burning them This could cause battery explosion Do not open or destroy batteries Escaping electrolyte can cause injury to the skin and eyes It may be toxic Please replace the fuse only with the same type and amperage in order to avoid fire hazards Do not dismantle the UPS system ee LA ITR LCD lapara 2 Installation And Setup NOTE Before installation please inspect the unit Be sure that nothing inside the package is damaged Please keep the original package in a safe place for future use 2 1 Rear Panel View LA ITR 800 LCD LA ITR 1100 LCD LA ITR 2500 LCD LA ITR 1 500 LCD LA ITR 2000 LCD LA ITR 3000 LCD m Programmable outlets connect to non critical loads Output receptacles connect to mission critical loads AC input Input circuit breaker Network Fax Modem surge protection Emergency power off function
11. city when the output voltage is adjusted to 208VAC Product specifications are subject to change without further notice 19 LA ITR LCD lapara
12. connector EPO USB communication port RS 232 communication port SNMP intelligent slot 10 External battery connector only available for L model 11 External battery pack numbers detection port Oe ND OT S oN a 2 2 Install the UPS For safety consideration the UPS is shipped out from factory without connecting battery wires Before install the UPS please follow below steps to re connect battery wires first Step 1 Step 2 Step 3 Remove front panel Comedi ihe AC input ut and Put the front panel back to the unit re connect battery wires ee SE LA ITR LCD lapara Rack mount Installation Step 1 Tower Installation Step 1 2 3 Setup the UPS Step 1 UPS input connection Plug the UPS into a two pole three wire grounded receptacle only Avoid using extension cords Step 2 UPS output connection There two kinds of outputs programmable outlets and general outlets Please connect non critical devices to the programmable outlets and critical devices to the general outlets During power failure you may extend the backup time to critical devices by setting shorter backup time for non critical devices Step 3 Communication connection Communication ports USB port RS 232 port Intelligent slot oG o y To allow for unattended UPS shutdown start up and status monitoring connect the communication cable one end to the USB RS 232 port and the other to the communication port of your PC With the monitoring soft
13. n 3 5 section o Setting Operation Indicates the setting operation nput Output amp Battery information I Indicates the output input voltage output input frequency or battery voltage V voltage Hz frequency alse Indicates the external battery pack numbers Load information ae r Li Indicates the load level by 0 25 26 50 51 75 and EN N oo eo 76 100 Indicates overload Indicates the load or the UPS output is short circuited Indicates that programmable management outlets are working Indicates that the UPS alarm is disabled F i iS Indicates the UPS powers the output directly from the mains 11 Indicates the battery charger is working T Indicates the UPS is working in boost mode FO Indicates the UPS is working in buck mode Battery information scien the Battery level by 0 25 26 50 51 75 and BATTERY O re LOW BATT Indicates low battery Indicates there is something wrong with battery ww wo gt Q o D gt D 3 Sounding every 4 seconds Sounding every second Sounding twice every second Continuously sounding LA ITR LCD alapora 3 4 LCD Display Wordings Index EOE 3 5 UPS Setting LOAD OVER LOAD 2 __ eee gt cs A co A a ale Parameters 2 There are two parameters to set up the q Su a a ep UPS a a A BATTERY Parameter 1 It is for program dat alternatives There are
14. nction Then press Enter button again to confirm the setting LA ITR LCD lapara Step 4 Press the Up button ON MUTE again to switch to 03 of program list Then press Enter button for setting programmable outlet time Push Up button to change the value of backup time according your demand Then press Enter to confirm the setting Step 5 Press Up button ON MUTE to switch to 00 of program list Then press Enter button to exit setting menu Step 6 Disconnect AC input and wait until the LCD display is off The new setting will be activated when turning on the UPS again 3 6 Operating Mode Description Operating mode LCD display ECO mode When the input voltage is within voltage regulated range UPS will power the output directly from the mains ECO is an abbreviation of Efficiency Corrective Optimizer In this mode when battery is fully charged the fan will stop working for energy saving Buck mode When the input voltage is higher than the when AC is voltage regulation range but lower than normal high loss point the buck AVR will be activated Boost mode When the input voltage is lower than the when AC is voltage regulation range but higher than normal low loss point the boost AVR will be activated Battery mode When the input voltage is beyond the acceptable range or power failure and alarm is sounding every 4 seconds UPS will backup power from battery L
15. ternal or internal Check if all batteries are and u__Hiashing battery is incorrectly connected well connected Line and neutral Rotate mains power conductors of UPS input socket by 180 and then are reversed connect to UPS system on LCD display and alarm is sounding every second Fault code is shown as 27 and Battery voltage is too high Contact your dealer or the charger is fault X the icon is lighting on LCD display and alarm is continuously sounding Fault code is shown as 28 and Battery voltage is too low Contact your dealer or the charger is fault xX the icon is lighting on LCD display and alarm is continuously sounding Tec AN dte co UPS is overload Remove excess loads are flashing on LCD from UPS output display and alarm is sounding twice every second Fault code is shown as 43 and The UPS shut down Remove excess loads the icon MM3 is lighting on automatically because of from UPS output and LCD display and alarm is overload at the UPS restart it continuously sounding output Fault code is shown as 14 and The UPS shut down Check output wiring and if alarm is continuously sounding automatically because connected devices are in short circuit occurs on the short circuit status UPS output 16 E SE LA ITR LCD lapara Symptom Fault code is shown as 1 2 3 4 A UPS internal fault has Contact your dealer 11 12 13 and 41 on LCD display occurred and alarm is continuously
16. ut it is not applied to the situations when warnings or errors Occur Up key Press this button to display previous selection in UPS setting mode Switch to UPS self test mode Press and hold ON Mute button for 5 seconds to enter UPS self testing while in AC mode Turn off the UPS Press and hold this button at least 2 seconds to turn off the UPS Confirm selection key Press this button to confirm selection in UPS setting mode Switch LCD message Press this button to change the LCD message for input voltage input frequency battery voltage output voltage and output frequency Setting mode Press and hold this button for 5 seconds to enter UPS setting mode when UPS is off gt Down key Press this button to display next selection in UPS setting mode 3 2 LCD Panel Rack Display Tower Display Load info OVER LOAD Battery info Input output and Battery l info Battery info Warning amp Fault info Input output _ Warning Setting operation nd Batt amp Fault info 2 sii Setting PS LC operation UPS status Backup G H UPS status time info LOAD l Load info EE J Backup time info 10 LAITRLCD lapara Display Backup time information Indicates the backup time in pie chart Indicates the backup time in numbers H hours M minute Warning amp Fault information Ju Indicates that the warning and fault occurs Indicates the warning and fault codes and the codes are listed in details i
17. ware installed you can schedule UPS shutdown start up and monitor UPS status through PC The UPS is equipped with intelligent slot perfect for either SNMP or AS400 card When installing either SNMP or AS400 card in the UPS it will provide advanced communication and monitoring options PS USB port and RS 232 port cannot work at the same time Step 4 Network connection Network Fax Phone surge port 5 eee S LA ITR LCD lapara IN OUT Connect a single modem phone fax line into surge protected IN outlet on the back panel of the UPS unit Connect from OUT outlet to the equipment with another modem fax phone line cable Step 5 Disable and enable EPO function Keep the pin 1 and pin 2 closed for UPS normal operation To activate EPO function cut the wire between pin 1 and pin 2 It s in closed status for UPS normal operation Step 6 External battery connection for long run models only Connect one end of external battery cable to UPS unit and the other end to battery box Use supplied battery detection wire in detection port of UPS unit and plug the other end to battery bank See below chart for detailed connection Battery Box NOTE Maximum connected external battery boxes up to 4 units Step 7 Turn on the UPS Press the ON Mute button on the front panel for two seconds to power on the UPS Note The battery charges fully during the first five hours of normal operation Do not expect full battery run capa