1.    A dedicated Intruder Alarm connection is provided     Site Layout Examples          Net2 plus Net2 plus Net2 plus Net2 plus Net2 plus Net2 plus    RS485 data line    TCP IP TCP IP TCP IP TCP IP  LAN LAN LAN LAN    Here are three typical site layouts     Net2 plus Net2 plus Net2 classic 1   The Net2 plus ACU s can be individually connected to  the Net2 PC via the site LAN network     2   The Net2 plus ACU s can be hardwired on a daisy  chain RS485 data line with ONE of them connected to  the Net2 PC via the site LAN network     RS485 data line 3   The Net2 plus ACU can be used as the TCP IP  TCP IP converter for a line of Net2 plus and Net2 classic ACU s     LAN       The TCP IP interface allows an RS485 data line to be controlled by the Net2 Server running across a LAN network     An RS485 data line has a 1 km maximum length  This distance can be increased by using Paxton high speed  repeaters or by using shorter independant data lines using multiple LAN connections controlled from the same PC     Control unit installation    Wire the components to the Access Control Unit  ACU  as shown on the first page  Power up the unit and wait for  the OK heartbeat     Press the exit button or in the absence of an exit button  short the OV and exit terminals together  The lock relay  LED will come on and the lock should release     The reader s default indication has all the LED s on  Access granted is denoted with a single flashing Green LED   Access Denied is a single flashing Red L
2.  and RS485 LED indication    The Net2 plus performs two functions  It is an access control unit and also a TCP IP RS485 converter  Information  can pass across the PCB between the TCP IP and RS485 data port but is not relevant to this ACU       Server Connected LED  Steady Green     This LED shows that the TCP IP interface is active and receiving data from the Net2 PC server  This includes all  data for other ACU s that may be linked via the RS485 data port       Rx and Tx LED s  These LED s show the activity for this ACU only  This is same indication as seen on a Net2 classic ACU     It is not dependant on the source  TCP IP or RS485   The Rx LED will flash for all data being received and the Tx  LED will only flash when this unit responds to its own address     Page 7    Specifications     features  amera YO EC  ThumberofPiNs S C8000 Nev  a G S o o  mems OOS o o a S  Mamu door operam   i   sess OO  wers OOo S S o S  osen OOOO CdS  response OOO S S o    o  esser OOOO S T o    T  ews OOO S T o      acu persotaine OO    a mese OOo o S o a   Dat retention ater soist powers   ve POC  Ss  Tethermetneworkspeed       tomos   momes    a a 20s O O  C T Cd  C a E  Crear   C eC Te   Poe current  ependng on say   4   tm  SO o S o S   Relay swtchabiecurent Oooo o a o  momomo OO O o o a o   contin rencer por owore     coma     ereronnent Min   Topeeting temperature  Beer mms   eee d ese OOOO    CE    This product is not suitable for retail sale  All warranties are invalid if this product 
3.  firewall virus protection software and other wireless hardware can block the IP detection process  Disable  these and try to detect the device again  Please contact Technical Support if you require further advice     If you detect the MAC address but the device now shows  Not Responding   you must check the IP address  to  make sure it is still in range with the PC or network  If it is not  you should either change the IP address of the  PC or the IP address of the device so they are both again in the same range  Our Technical team can talk you  through this if you need help     If the MAC address does not appear when you click Detect  ensure that the following ports are open on all devices  between this unit and the Net2 PC         TCP IP Reset   The unit can be returned to DHCP settings by powering down the unit and linking the Brown and  Mauve terminals on reader port 2  Power up the unit again and the unit will beep to acknowledge the link  You  may now remove the link and the OK LED will flash fast for a few seconds  When the OK LED returns to a steady  heartbeat  the IP settings will be reset to DHCP     If you still cannot detect the MAC address of the device  call our Technical Support Help line     The device will    beep    when detected by the Net2 Server Configuration Utility or when new IP settings are applied   The sounder will also respond to a direct  Ping  over the network  This is a feature to assist with finding devices  hidden from view     Connecting to 
4. 30 08 2012 v  Ins 30080 Net2 plus control unit Paxton    Technical Support  6  01273 811011 support paxton co uk    Technical help is available  Monday   Friday from 07 00   19 00  GMT   Saturday from 09 00   13 00  GMT     Documentation on all Paxton products can be found on our website   http   www paxton co uk        The Net2 plus can be connected to the PC via an RS485 data line or a TCP IP connection   This unit requires the controlling PC to be running Net2 v4 14 or later software            12V DC  Wiring Intruder alarm integration power supply    YIVIVIVIG           O O     O  O   Co    JES    Fail closed release    http   paxton info 107    UTM  123456    00 01 02 03 04 05    Exit button   push to make     Reader keypad         Q  i  O  Q       Door contact switch   held closed by door     OOO            VIV V  VIO           lt     lt       a WADA  Switchable WAY al  120 ohm  gt  X  resistors Tamper switch   optional   TCP IP patch lead   The Net2 plus ACU has 2 reader ports and From previous To next For a fail open lock  3 output relays  but can control just one ACU ACU  Maglock   wire OV to the  door  The configuration of one control  N C   terminal instead of  unit per door greatly simplifies installation  N O      and is ultimately highly cost effective     LED indications    12V  Green    Power LED    Relay 1  Orange    The relay is energised    N O  COM contacts are closed    Relay 2  Orange    The relay is energised    N O  COM contacts are closed    Alarm  Re
5. CP IP interface must be listed in the Net2 Server Configuration Utility  and responds when PINGed  from the utility  A static IP address must be used for the interface   2  If the interface is responding  try a loopback test   see Loopback section   3  The Net2 data line should be checked for resistance readings     6   Readers  Keypads not working      Software settings   Confirm that the settings of the reader or keypad are correct      Connections   Check the wiring and integrity of the connectors    If possible  test this reader on the other port      Cable   Belden 9540 should be used to extend the reader cable  100 m maximum   Twisted pair alarm cable  Should not be used  To confirm that a cable extension is not at fault  wire the reader direct into the reader port      Supply voltage   Confirm that the voltage is within specification   see table      User token   Confirm that the user token used for testing is OK by presenting it to a Known working reader      Interference   Confirm whether the reader works when tested  in hand  and not mounted on the wall  Ensure  that readers are not mounted back to back or there is no interference from other local RF devices     Page 6    Here is the list of topics about this product that receive the most technical support enquiries     We list them here to help you speed up the installation and trouble shooting process        7   Fire alarm integration   Net2 Professional software must be used   A voltage free normally closed conta
6. ED     Remember  the Net2 plus is a combined TCP IP interface and an Access Control unit  If the TCP IP interface is  being used  you will need to detect the interface first using the procedure on the following page     This is important if you are replacing an existing Net2 plus  The Replace wizard in the Doors screen does NOT  reconfigure the IP address so it must be done manually  The wizard will then copy across the user data     Each time the unit is powered on  it will run an internal health check  During this phase  about 5 secs  the OK  LED will flash quickly before changing to a slower heartbeat     Page 2    Connecting to the PC via the Ethernet port    The IP address should be assigned a fixed value  or should be given a DHCP reservation  Unreserved IP addresses  issued by DHCP servers are not guaranteed to be constant  leading to potential failure of communication between  Net2 software and the device     Run the Net2 Server Configuration Utility  Start Programs Net2  and Click on TCP IP nodes         Net2 Server Configuration Utility   x      Net2 Server Configuration Utility TE    General   Database   Wiegand   Dial up nofes TCP IP nodes   New Ait Bridge   Paths   System   Features   Diagnosti_    gt   General   Database   Wiegand   Dial up nodes TCP IP nodes   Net2air Bridge   Paths   System   Features   Diagnosi a   gt            m TCP IP nodes     TCP IP nodes  Name MAC address Add  Name   MA address Add    5th unit 00 49 D6 0E 49 7E Net2 plus 0 12  0 05   De
7. P IP interface  any fixed IP settings will be retained   If the unit is in DHCP mode it will need to be detected at each stage using the Net2 Server Config Utility  as a new address may be issued by the IP server  each time the PCB resets     3   Can we use a DHCP IP address   The Ethernet interface does support DHCP  but for more reliable communication  a static IP address must be  reserved for the unit  This is because some servers issue different DHCP addresses each time they are restarted  and this requires the Net2 interface to be manually set up again   a time consuming process     4   TCP IP   Direct PC connection   Connect the network interface directly to the LAN port of the PC  Without the presence of a DHCP server the unit  will default to an IP address in the range 169 254 X X     Check the IP address of the network card of your PC by typing IPCONFIG at the command prompt  Detect the  TCP IP interface with the Net2 Server Configuration Utility and change the IP address to an address   similar to that of your machine  For example  if the IP address of the PC is 192 168 10 7  change the IP address  of the TCP IP interface to 192 168 10 8  Once the IP address of the interface has been changed into the range of  the PC then Net2 will be able to communicate with it     NOTE  Do not change the IP address of your PC to 169 254 x x  this will not allow the IP address of the TCP IP  interface to be fixed correctly     5   Cannot detect ACU via a TCP IP interface   1  The T
8. To run the test  go to Net2 Server Config Utility TCP     IP Nodes Advanced and click on Loopback test  If the test fails  connect the unit directly to the PC with an RJ45  patch cable and test it again  Should this still fail  please call Technical Support for further advice     Connecting to the PC or other ACU s via the RS485 data connection    90  of installation faults are caused by wiring errors on the RS485 data line   Special attention to getting this right first time saves a lot of time and effort     END OF LINE TERMINATION SWITCHES     These should all be OFF except for those at both ends of the data line     READER  amp  DATA CABLE SCREENS     Data cable screens and spare cores MUST be connected throughout       Reader and keypad screens where provided should be connected to the Black  OV  terminal     Reader        Net2  Server        Control unit    LAN WAN    The data line must be wired in a single daisy chain  The data converter may be located anywhere along the data  line  120 ohm terminating resistors must be linked across each data pair at the beginning AND end of the line   This can be done on many units with a switch or jumpers  If not  free resistors are provided with the converter     RS485 data line resistance checks    Power down all TCP IP  USB and RS232 converters  individual and Net2 plus      S Check the resistance across each data pair is 60 80 ohms     S Check that there are no data line to screen shorts     S Check the screen of the data cable 
9. a WAN or different subnet mask    If you are connecting this device to a remote subnet which is different from the Net2 software PC  the standard  detect mechanism cannot work across the network routers between them  The IP address  along with the correct  subnet mask and gateway for the remote subnet have to be set  Either do this on the local subnet with the  existing Net2 PC  or use a PC on the remote subnet once the device is installed     The PC that has the Net2 server installed must be able to access the IP address range on the WAN remote site     Page 3    This may require the routers and gateways to be configured between the networks  Again  this would be done by  the Network administrator of that site  Make sure the ports listed above are open on all intermediate routers     Once installed  create a record with the Add button  if none was created during initial set up  and you should then  be able to detect its MAC by entering the IP address in the Configuration screen Ping box     TCP IP Loopback test    The following test should be run if there are problems setting up the IP configuration of the interface  This test  sends data to the device and checks this against the data it receives back  This confirms that the network is  working correctly     The Net2 server program must be shut down during this test   Remove any wires from the RS485 data line connector and create a hardwired data loop as follows  Connect  the Orange to White Green and Green to White Orange  
10. ct from the fire alarm system should be wired across an ACU input     Contact PSU Tamper Exit   The doors that are required to open from that trigger are set up in the software for  that ACU under the Fire Alarm Tab     NOTE  The doors are relocked from the PC software   resetting the Fire panel will have no effect on the system   The Net2 Server MUST be running at all times for this method to work     Fail open locks are required on fire doors  Break glasses should be installed to drop power to the lock manually     8   RS485 data line cable layout   Net2 classic and Net2 plus     The data line must be wired in a daisy chain  End of Line  1200hm  resistors must be fitted switched across  both pairs at each end of the line     Repeaters must be used over 1000 metres and can be used to create a branch from the daisy chain  Cat5 or  Belden 8723  4 Core Twisted pair  must be used for the data line  The cable screen must be connected  throughout for reliable communication  Cat5 must have spare cores terminated in lieu of screen cable     9   Timesheet   Why Time  amp  Attendance must have dedicated readers for logging in out   In the vast majority of applications using the same reader for access and T amp A is not practical  Traffic through the  access points causes long  unmanageable T amp A reports  It is therefore NOT possible to set this up in the software   Proximity or Cardlock readers set up as Clocking in or Clocking out readers have no effect on Relay 1 and will not  app
11. d    12V Alarm output is active    Exit  Orange    The exit button contacts are closed    Contact  Orange    The door contacts are closed    Tamper  Orange    The tamper contacts are closed    PSU  Orange    The PSU contacts are closed                                OK  Green flash    The internal software is running    Termination  Red    The on board resistors are in place across the RS485 data pairs    Rx  Red    The ACU is receiving data  TCP IP or RS485    See also FAQ section   TX  Green    The ACU is responding to data    TCP IP or RS485     Server Connected  Green    The TCP IP interface is communicating with the PC Net2 server   Server Link   Green   100 Mbit s   Orange   10 Mbit s  TCP IP speed                        Page 1    A Net2 plus can connect to the Net2 PC using either an un shielded RJ45 patch cable or an RS485 data line  This  greatly increases the number of installation options available to the installer     One Net2 plus can also be used as the TCP IP interface for an RS485 daisy chain of Net2 plus and Net2 classic units     When used with a TCP IP connection  it must first be detected using the Net2 Server Configuration Utility  See later  section of this instruction and AN1006   Installing remote sites using TCP IP  lt  http   paxton info 51  gt     When used with an RS485 data line  on board termination resistors can be put in circuit with a simple slide switch   Ensure that units installed in the middle of the data line have this switch turned OFF  
12. ear in Access levels  Relay 2 will switch for half a second to allow confirmation by fitting an LED or sounder     10   TCP IP communication over a WAN   We need to establish two way communications between a PC on site A and the TCP IP interface on Site B     The paths that the PC and the TCP IP interface will use are different  but they each need to know the IP address    they are trying to locate on the other site as well as the gateway IP address that will route their requests from  their own LAN to the other LAN       TCP IP Interface set up  Site B    You need to set the IP address for the TCP IP interface that will define it within it s own LAN   e g  10 10 0 25      You need to set the gateway IP address of the local    router     in the TCP IP interface  This is so that the router will  know that any reply from this interface needs to be sent back to the other LAN     NOTE  All the information required to get back to the sending PC on site A is done automatically by the network  hardware  the    site A  PC includes its own IP address in the outgoing message       PC Set up  Site A      Most LAN addressing is set up such that different groups are reserved for specific remote sites  It is then just a  case of setting up the IP address of the TCP IP interface on site B  10 10 0 25  in the PCs  Net2 Server  Configuration Utility  all the outward routing is done automatically by their network hardware     Port  9999  must be allowed through any firewall software     TCP IP
13. g a  Multimeter  measure the resistance across the White Green and Green pair at one end of the network   A resistance of between 60 and 80 ohms is required  Repeat the test for the White Orange and Orange pair   This is vital for a stable and trouble free installation     2   ACU Reset   No OK LED flashing   The ACU has no factory reset condition as it does not contain any fixed settings  The unit does have an operating  program  firmware  that controls its functions and can be confirmed as running by means of the flashing OK LED     If the OK LED is flashing steadily  then there should be no reason to reset the unit     If the OK LED is not flashing  you need to clear the unit so that it can receive a firmware download from the PC   Any other ACU s without OK LED s must be taken off the line or powered down     Stop Net2 Server  Net2 server icon   Bottom right of screen   Right mouse click  Select Stop the Net2 Server    Power down the Net2 ACU    Insert a link wire between the Orange and Mauve terminals on reader 2 port    Power up the ACU    The OK LED flashes very quickly    With the unit still powered  remove the link    Go to the PC and Start the Net2 Server and go into the Doors screen  Click on the Detect button  This  should look for the ACU and then download its firmware  This may take up to 5 minutes     The OK LED  Should now be flashing with a steady heartbeat  This procedure must only be done for one ACU at a time     Oe SI    NOTE  If this unit is using the TC
14. is continuous   this provides the OV DC system reference        Page 4    Software Configuration    E Net  Access Control    ions Help Door name  Name the Door   aS A  Door open time  Set the door open time    E k  m   Retesh   5  Print G Find D  it c an   A   A ie Unlock the Door during  Holds the door unlocked during        Net  Access Control Front Door this timezone    Set to    At No Time    for normal user  ES  Events ACU serial number OUYA260  Operation        S28 Users Door name ACC    e o   Door open time  seconds    7   Cancel    BA Administration z     8 Communications Unlock the door during Reader 1  Settings for Reader 1 and Keypad 1 on the ACU        Sd Access levels   Ss Timezones  H Doors    Reader 2  Settings for Reader 2 and Keypad 2 on the ACU   Alarm  Contains settings for the different types of alarm   Codes  Valid codes can be viewed  added and removed     EE Areas Reader 1   Reader 2   Alarm       Can only be viewed when a keypad is active    T Anti passback Reader details Events  Shows the events for the control unit selected   A IO Boards Name ont Door  Ir  Y Triggers and Actions Reader type ee E       i keppad type Name  Each reader can be named individually if required     Rall call ee ey ne Reader type  Set the reader type  if applicable   3S Net  operators Keypad type  Set the keypad type  if applicable   Operating mode Token data format  Select the data type being used on    Reade ane int made the system   New formats can be created    Net  actio
15. is not installed by a competent person        Page 8    
16. lete m  2e   4th unit 00 49 D6 DE 49 7F Net2 plus 0 12  0 05  __ Delete    Rename   3rd unit 00 49 D6 0E 49 80 Net2 plus 0 12  0 05  Rename      2nd unit 00 49 D6 0E 49 87 Net2 plus 0 12  0 05   1st unit 00 49 D6 0E 49 86 Net2 plus 0 12  0 05  Detect         Click  Detect  to automatically find any TCP IP nodes on your network  Click  Detect  to automatically find any TCP IP nodes on your network     Configuration   IP address configuration   Advanced   Configuration IP address configuration   Advanced    IP Add   Pn You can get an IP address assigned automatically if your network supports this capability  Otherwise you need to ask  ress 9   your network administrator for an IP address    Download events Iv    Firmware version 0 12    Obtain an IP address automatically  use DHCP   MAC address 00 0B D6 0E 49 7E       Use the following IP address    Interface mode  RS 232     RS 485 New IP address   105  10    2     5 Ping    Port number fi 0001 Subnet mask  optional    255 255 0 0 v    Default gateway  optional   OE  AD AA oF  Update firmware                                 Cancel      Click on Detect and the MAC address of the device s  will appear in the table  You must then use the  IP address  configuration  tab to manually assign the IP address  subnet mask and gateway     Be aware that if the IP address that you give the device is not in the same IP range as the PC  the device will no  longer respond until you connect to it with a PC that is in the same IP range     Some
17. ns    E Open door  E  Timed operating modes   This allows for different reader operation during a selected timezone   Aoao aU ae ae Ald  Reader operating mode  Set the operating mode   This reader will operate as  s  Timed operating modes  A different operating    Net  details mode can be configured within a time window   eee Reader action   This i   what will happen whetrecranracce PTET       Relay 1 opens for door open time 3 Rela    z Reader action  Set the action required  Net  documentation  e Baa when access is granted     PC Installation    The current specification for compatible PC hardware  network and operating systems is available on our website at    the following link  http   paxton info 720       Intruder alarm integration    A dedicated port for input and output signals is provided when integrating a Net2 plus ACU with an alarm system     Please see AN1035   Integrating Net2 with an intruder alarm system  lt  http   paxton info 91  gt  or call Technical  Support for further information     VON ON       Arm   Confirmation Push Button   Wire across OV and Arm   Sense   Requires a voltage free loop across OV and Sense to confirm when alarm is active   Set   Relay provides contacts across COM and N O  for a voltage free loop to set the alarm     Page 5    Technical Help       1   RS485 Data line resistance check   ACU not responding or fails to be detected   First power down any data line converters and disconnect any ACU s that do not have a flashing OK LED  Usin
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
  2.5イ ンチSATA SSD 取扱説明書  Xerox WorkCentre 6015 Quick Reference Guide  Politique des usages, II : « La politique, mode d`emploi ».  Sunbeam 6166-33 Toaster User Manual  DediProg SF Software User Manual  government of sindh civil hospital, karachi tender  Frame It All 300001080 Instructions / Assembly    Copyright © All rights reserved. 