1. MiniRao Installation Overview Congratulations on your purchase of the MiniRaO vertical rack system The MiniRaQ is available in 4U 6U and 8U sizes based on size and usage restrictions for a variety of applications The MiniRaO is designed from heavy gauge steel and finished to last a lifetime It is designed to hold up to 400 pounds when properly installed for your most demanding needs such as extended runtime battery back up systems low profile power distribution transformers POE equipment and many other rack mountable products For installing the MiniRaQ System into any other surface not specifically mentioned in this manual please consult local building code requirements Warning to insure safe and secure installation The MiniRaO System can be mounted on a variety of vertical substrates including wooden framing studs 16 on center solid or block concrete walls and approved plywood electrical panel or directly onto existing 2 Post racking Please see detailed instructions on the following pages Mounting hardware is provided for installing into solid wall studs and 12 24 screws for mounting on 2 Post rack The MiniRaO can even be mounted in a 2 Post rack Back to Back configuration if clearances allow which may increase U space utilization in some instances Built in level allows easy installation Top access for data for single service personnel or power cabling The apparatus a
2. Drill 5 32 pilot holes for 3 16 bolts or 3 16 for 1 4 bolts pilot holes as required by manufacturer Apply TAPCON or equivalent concrete double threaded screws A minimum 2 1 4 length is recommended for full rated loading of MiniRaQ Lift main back panel and hand tighten bolts and washers not supplied most of the way into wall Tighten all screws Next go to bracket installation details pg 7 A Caution The MiniRaO must be properly installed to a suitable surface and using recommended hardware per instructions provided Warning www minirag com PAGE 6 Bracket Installation Details for MiniRaQ System With the MiniRaO main back panel mounted the left and right brackets can be set in place and secured The MiniRaO main back panel accommodates all brackets sizes available 4U 6U and 8U versions Proper orientation is required to secure brackets after engaging the tabs to allow safety screw placement Left Bracket 74 F Right Bracket Inside surface A Smooth surface with tabs faces out Bracket Arm Security screw located here 1 each bracket FIGURE 6 Engage one bracket at a time confirming all tabs are nested into cutouts on MiniRaO main back panel 1 and slide down to fully set bracket The clearance hole in the bracket 2 should now align with a threaded hole in the MiniRao main back panel Apply a 12 24 screw supplied and tighten Repeat with opposite brack
3. R IN CONNECTION HEREWITH BHL DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY SATISFACTION AND FITNESS FOR A PARTICULAR PURPOSE BHL EXPRESS WARRANTIES WILL NOT BE ENLARGED DIMINISHED OR AFFECTED BY AND NO OBLIGATION OR LIABILITY WILL ARISE OUT OF BHL RENDERING OF TECHNICAL OR OTHER ADVICE OR SERVICE IN CONNECTION WITH THE PRODUCTS THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES THE WARRANTIES SET FORTH ABOVE CONSTITUTE BHL SOLE LIABILITY AND PURCHASER S EXCLUSIVE REMEDY FOR ANY BREACH OF SUCH WARRANTIES BHL WARRANTIES RUN ONLY TO PURCHASER AND ARE NOT EXTENDED TO ANY THIRD PARTIES www minirag com PAGE 9 BHL WILL IN NO WAY BE LIABLE FOR ANY FORM OF INDIRECT SPECIAL CONSEQUENTIAL OR PUNITIVE DAMAGES ARISING OUT OF THE USE SERVICE OR INSTALLATION OF THE PRODUCTS WHETHER SUCH DAMAGES ARISE IN CONTRACT OR TORT IRRESPECTIVE OF FAULT NEGLIGENCE OR STRICT LIABILITY OR WHETHER BHL HAS BEEN ADVISED IN ADVANCE OF THE POSSIBLY OF SUCH DAMAGES SPECIFICALLY BHL IS NOT LIABLE FOR ANY COSTS SUCH AS LOST PROFITS OR REVENUE LOSS OF EQUIPMENT LOSS OF USE OF EQUIPMENT LOSS OF SOFTWARE LOSS OF DATA COSTS OF SUBSTITUANTS CLAIMS BY THIRD PARTIES OR OTHERWISE NO SALESMAN EMPLOYEE OR AGENT OF BHL IS AUTHORIZED TO ADD TO OR VARY THE TERMS OF THIS WARRANTY WARRANTY TERMS MAY BE MODIFIED IF AT ALL ONLY IN WRITING SIGNED BY AN BHL OFFICER AND LEGAL DEPARTMENT Warranty Clai
4. ainst the wall in the preferred location Confirm location of stud centers and for at least one TOP pilot hole Drill pilot hole using 5 32 bit not supplied Place the first 10 Wood screw through top slot B and insert screw most of the way into stud Using integrated level adjust panel and drill remaining TOP Pilot hole and insert screw most of the way into stud FIGURE 4 All remaining pilot holes can be drilled and screws inserted into holes as above Tighten all screws Next go to bracket installation details pg 7 www minirag com PAGE 4 Mounting to Cinder Block or Approved Hollow Wall Hole Pattern C Place the MiniRaO main back panel against the wall in the preferred location Using integrated level adjust panel to level thenmark a minimum of the two top and two bottom 2 inch clearance holes Hole C Drill marked holes and apply Togglers or other associated inserts as required Lift main back panel and hand tighten bolts and fender washers not supplied most of the way into stud Tighten all screws Next go to bracket installation details pg 7 An approved hollow wall application is considered to be either of the following Cinder Block wall or NEC type 3 4 plywood electrical panel backing using Ne toggle bolts is safe for full rated load of MiniRaQ System In the event that this bracket is to be mounted on a block wall 1 4 x 3 toggle bolts should be used to support it It will be impor
5. et FIGURE 7 www minirag com PAGE 7 MiniRaQ Specifications Item Measurement Height 19 25 in 489 mm Width 19 00 in 483 mm Depth 4U version 9 50 in 241 mm 6U version 13 00 in 330 mm 8U version 16 50 in 419 mm Net Weight 4U version 13 0 Ib 5 9 kg 6U version 16 0 Ib 7 3 kg 8U version 19 0 Ib 8 6 kg Maximum Equipment Depth 38 00 in 965 mm Effective Rack Mounting Space 4U version 4U 2U Patch Panel 1U each on Sides 8U 6U version 4U 2U Patch Panel 1U each on Sides 10U 8U version 4U 2U Patch Panel 1U each on Sides 12U Total Equipment Weight Capacity 400 00 Ib 181 44 kg Material Heavy Duty 14AWG Steel Finish Chip Resistant Black Powder Coat Shipping Dimensions 20 X 20 X 3 inches All Versions Shipping Weight 4U version 15 0 Ib 6 8 kg 6U version 18 0 Ib 8 2 kg 8U version 21 0 Ib 9 5 kg Pallet Quantity 48 Specifications are subject to change www minirag com PAGE 8 BlackHawk Labs LLC Limited Factory Warranty The limited warranty provided by BlackHawk Labs LLC BHL in this Statement of Limited Factory Warranty applies only to Products purchased for commercial or industrial use in the ordinary course of your business Terms of Warranty BHL warrants its products to be free from defects in materials and workmanship for a period of five years two years in Japan from the date of purchase Its obligation under this warra
6. llows attachment for 1U or 2U patch panel directly inside the back panel without sacrificing any space in the mounting surface of the side panels Lances are incorporated into the MiniRaQ to allow data and power cable management for input and output wiring using either top or bottom egress as well as to facilitate service loops O oo0oo0o00o0 D Earth Grounding Stud integrated further assisting quick and convenient system install Large rear panel access allows Pass though cable routing in 2 Post Back to Back mounting applications aa Back plate of apparatus is designed with 3 mounting options A hole pattern 10 allows mounting in standard 2 post open frame rack Ancillary equipment both rack and non rack mountable can be attached to the side of the back panel by hanging or screwing g onto the back panel B Slots are centered at 16 inches for 10 by 2 screws 10 into studs or other solid wood surface e C hole pattern 10 accommodates toggle bolts for mounting on block wall or NEC electrical panel grade plywood All Trademarks are the property of their respective owners Patents pending BlackHawk Labs LLC Copyright 2007 www minirag com PAGE 1 MinikRaO Detailed Installation Instructions First confirm that the main back panel of the MiniRaQ will be
7. mation s Page 8 www minirag com PAGE 2 2 Post Rack mounting option Hole Pattern A Using supplied 12 24 screws align and insert 1 screw Do not fully tight screw but engaged enough to hold up back panel Using integrated level adjust panel and add second screw to opposite post Add remaining 8 screws and then tighten all Next go to bracket installation details pg 7 cep ibid a erates Level to locate proper mounting pattern 10 screws recommended for full payload rating of system Secure both top and bottom of 2 Post Relay Rack before loading MiniRaa o 0 00 0 00 0 00 0 00 0 00 0 000 000 oo 0 000 Qo o 00 0 00 0 00 0 00 0 00 0 000000 o D Close up detail of 2 Post Mounting option s ere enonse N O FIGURE 3 www miniraq com PAGE 3 Close up detail of Locate solid studs 16 inches on center before marking top two 16 Center to Center locations for pilot holes Mounting option Drill 156 at the top using the integrated level to locate proper mounting pattern Begin installing supplied screws in pilot holes at the top then drill and install remaining screws in the pattern 10 screws recommended for full payload rating of system Mounting into 16 inches on center solid wood wall studs Hole Pattern B Place the MiniRaQ TM main back panel ag
8. mounted onto a recommended surface and be sure proper hardware is available to proceed Hardware is supplied for both 2 Post rack kit contains 10 12 24 relay rack screws and wooden framing studs 16 on center kit contains 10 10 x 2 Stainless Steel screws If installing into concrete or approved plywood electrical panel be sure to have appropriate 1 4 hexhead concrete screws lag bolt inserts or toggle bolts before continuing with installation O 10 fasteners are recommended for full rated load n 10 fasteners are recommended for full rated load Mounting main back panel for MiniRaQo Close up detail of Mounting hole patterns for different hardware options Available to install the MiniRaQ System FIGURE 2 2 Post Rack mounting option Hole Pattern A s nssennnsenunnsnnnnnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn mnnn Page 3 Mounting into 16 inches on center solid wood wall studs Hole Pattern B ccssseeesesnnes Page 4 Mounting to Cinder Block or Approved Hollow Wall Hole Pattern C ccccsssseeesssseeessssteeeseseeenes Page 5 Mounting to Concrete Wall with Compression Lags Hole Pattern C ccscsssseesseeeeseees Page 6 Mounting to Concrete Wall with TAPCON bolts Hole Patteri Co nicsecisenstedasectensndect cers ccisesendicetesesnssennssdzeedsenay Page 6 Bracket Installation Detalll s ccsceeseeseeeeeeeees Page 7 Specifications and Warranty Infor
9. ms Customers with warranty claims issues may access the BHL worldwide customer support network by visiting www bhpower com support BHL Customer Support Customer support for this or any other BHL product is available at no charge in any of the following ways e Visit www MiniRaQ com webite to access documents and to submit customer support requests e www bhpower com Corporate Headquarters Customer Support Line 877 427 2522 toll free BHL headquarters USA BlackHawk Labs LLC 829 W Stadium Lane Unit B Sacramento CA 95834 Please recycle packaging materials Entire contents copyright 2007 BlackHawk Labs LLC All rights reserved Reproduction in whole or in part without permission is prohibited BHL the BHL logo and MiniRaQ are trademarks of BlackHawk Labs LLC All other trademarks product names and corporate names are the property of their respective owners and are used for informational purposes only www minirag com PAGE 10
10. nty is limited to repairing or replacing at its sole discretion any such defective products This warranty does not apply to equipment that has been damaged by accident negligence or misapplication or has been altered or modified in any way Repair or replacement of a defective product or part thereof does not extend the original warranty period Any parts furnished under this warranty may be new or factory reconditioned Non transferable Warranty This warranty applies only to the original purchaser who must have properly registered the product Product may be registered at www bhpower com support Exclusions BHL shall not be liable under the warranty if its testing and examination disclose that the alleged defect in the product does not exist or was caused by end user s or any third person s misuse negligence or improper installation Further BHL shall not be liable under the warranty for unauthorized attempts to repair or modify inappropriate on site operating conditions corrosive atmosphere installation a change in location or operating use exposure to the elements Acts of God fire theft or installation contrary to BHL recommendations or specifications or in any event if the BHL serial number has been altered defaced or removed or any other cause beyond the range of the intended use THERE ARE NO WARRANTIES EXPRESS OR IMPLIED BY OPERATION OF LAW OR OTHERWISE OF PRODUCTS SOLD SERVICED OR FURNISHED UNDER THIS AGREEMENT O
11. tant that the hollow pocket in the block is located so that the toggle can open properly to support the weight Toggle bolt clearance hole is 1 2 bolts and washers not supplied available for purchase separately Note This Illustration shows recommended mounting pattern for concrete screws with fender washers lt 5 a m o O o a bdl fe 7 o O i o w w w o o o o 0 a we Ny ae j FIGURE 5 www miniraq com PAGE 5 Mounting to Concrete Wall with Compression Lags Hole Pattern C Place the MiniRaO main back panel against the wall in the preferred location Refer to Figure 5 on Page 5 for correct mounting hole pattern Using integrated level adjust panel and to level and mark a minimum of the two top and two bottom 1 inch clearance holes Hole C Drill marked holes as required and apply compression studs or other associated inserts as required Lift main back panel and hand tighten bolts and fender washers not supplied most of the way into stud Tighten all screws Next go to bracket installation details pg 7 Mounting to Concrete Wall with TAPCON bolts Hole Pattern C Place the MiniRaQ main back panel against the wall in the preferred location Refer to Figure 5 on Page 5 for correct mounting hole pattern Using integrated level adjust panel and to level and mark a minimum of the two top two bottom and two middle 1 2 clearance holes Hole C
Download Pdf Manuals
Related Search
Related Contents
SODAR MSc Thesis - Roger Carter INSTALLATION MANUAL Targus 12" Slipcase w/ Accessory Pocket Guia do Usuário do Dell Latitude X1 HygroPro - GEセンシング&インスペクション・テクノロジーズ Si desea los números de teléfono de Atención al Cliente, consulte la DUMPER 7 DUMPER 10 SMART user manual E CURSO INTENSIVO DE JOOMLA Copyright © All rights reserved.