Home

Gefen GEF-HDCAT5-ELRPOL2

image

Contents

1. 1080P HIM PROGRESSIVE HIGH DEFINITION MULTIMEDIA INTERFACE Extender for HDMI ELR with POL 2 over CATS GEF HDCATS ELRPOL2 User Manual www gefenpro com ASKING FOR ASSISTANCE Technical Support Telephone 818 772 9100 800 545 6900 Fax 818 772 9120 Technical Support Hours 8 00 AM to 5 00 PM Monday thru Friday Pacific Time For 24 7 support see the back of the product for the support number Write To Gefen LLC c o Customer Service 20600 Nordhoff St Chatsworth CA 91311 support gefenpro com www gefenpro com Notice Gefen LLC reserves the right to make changes in the hardware packaging and any accompanying documentation without prior written notice Extender for HDMI ELR with PoL 2 over CAT5 is a trademark of Gefen LLC HDMI the HDMI logo and High Definition Multimedia Interface are trademarks or registered trademarks of HDMI Licensing in the United States and other countries 2012 Gefen LLC All rights reserved All trademarks are the property of their respective owners Rev A5 oO 0 O O N O aA WO N DN DN Aa eee O 0 O N A N N OO CONTENTS Introduction Operation Notes Features Sender unit Layout Sender unit Descriptions Receiver unit Layout Receiver unit Descriptions IR Remote Control RMT 2IR Remote Control Installing the Battery Setting the IR Channel Connecting the Extender for HDMI ELR PoL 2 over CAT5 Wiring Diagram DIP Switch Configuration S
2. field please adhere to the TIA EIA568B specification See page 18 for details Connect the included AC power cord to the Sender unit Plug the power cord into an available electrical outlet NOTE Connect an optional power cable CAB PWR O6LL or CAB PWR 06NL to the Receiver unit The Receiver unit supplies 5V DC 2 5A to power an additional device Power on the HDTV display and the Hi Def source s connected to the Sender unit and the Receiver unit 10 CONNECTING THE EXTENDER FOR HDMI ELR WITH POL 2 OVER CAT5 Wiring Diagram for the Extender for HDMI ELR with PoL 2 over CAT5 Gefen PRO CAT 5 LINK CABLE ME ETHERNET CABLE 100BASE T Router N Set Top Box RS 232 CABLE 2 a HDMI CABLE THA 5 V DC POWER 120 V AC Device 120 V AC POWER Sender 6 RS 232 Controller Receiver HD Display Digital Signage Creator or other local source GEF HDCAT5 ELRPOL2 WARNING This product should always be connected to a grounded electrical socket 11 DIP SWITCH CONFIGURATION Sender Unit The Extender for HDMI ELR with PoL 2 over CAT5 contains two DIP switches on the bottom of the Sender Unit Each DIP switch performs a different function DIP switches located on the bottom of the Sender Unit DIP Switch 1 Green Mode Default OFF e OFF Enable Green Mode When DIP switch 1 on the Sender Unt is set to the OFF position the Sender Unit is placed in Green Mode In this mo
3. D from the display device EDID features newer than HDMI 1 3 are removed when the display is read This provides a general EDID which is compatible with more displays 14 DIP SWITCH CONFIGURATION Receiver Unit DIP Switch 2 Hot Plug Detect Default OFF ON HPD Pass Through HPD follows upstream HPD towards the source The HPD signal will reflect the connection status between the display device and the source device If the source or monitor is temporarily disconnected then reconnected there will be a delay of 20 30 seconds before the content is restored to the monitor OFF HPD Always High The HPD signal remains high regardless of the downstream HPD state If the source or monitor does not properly handle HPD no picture after connecting reconnecting source or display set this DIP switch to the OFF position DIP Switch 3 Support DVI Connections Default OFF ON Disable HDCP If a DVI connection is used set DIP 3 to the ON position DVI is supported by disabling HDCP pass through OFF Enable HDCP If an HDMI device is connected set DIP 3 in the OFF position DIP Switch 4 and DIP Switch 5 IR Channel The diagrams below indicate the settings for DIP switches 4 and 5 in order to set the IR channel on the Extender for HDMI ELR with PoL 2 over CAT5 Channel 0 default Remote Channel 1 Remote Channel 2 Remote Channel 3 O NOTE DIP switch 2 HPD and 3 HDCP are operational only if DIP swit
4. Dolby TrueHD DTS HD Master Audio M 1 OPERATION NOTES READ THESE NOTES BEFORE INSTALLING OR OPERATING THE EXTENDER FOR HDMI ELR WITH POL 2 OVER CAT5 The Extender for HDMI ELR with PoL 2 over CAT 5 units are housed in a metal box for better RF shielding CAT 5 cables should not exceed 330 feet Shielded CAT 6 with metal RJ 45 connectors are recommended to safeguard against random video flashes caused by electromagnetic interference EMI The Extender for HDMI ELR with PoL 2 over CAT5 features the ability to generate compatible EDID and Hot Plug signals for troubleshooting purposes when dealing with difficult interfacing issues between Source devices and Displays Refer to page 13 for details HDCP content is not supported when the unit is in DVI mode See page 16 for details Ethernet works as a Full Duplex system FEATURES HDMI Features e 225 MHz up to 12 bit YUV 444 1080p e Deep Color e x v Color e Dolby TrueHD and DTS HD Master Audio e Lip Sync 3DTV Features e Extends HDMI at 1080p Full HD and 1920x1200 up to 330 feet e Extends RS 232 up to 330 feet over a single CAT5 e Supports high bit rate audio formats Dolby TrueHD and DTS HD Master Audio e Supports 3DTV e Locking HDMI input port on Receiver unit allows the connection of a secondary Hi Def source e Source switching between Sender unit source and Receiver unit source e Fully HDMI and HDCP compliant e EDID mana
5. ELR with PoL 2 over CAT5 For example if both DIP switches on the IR Remote Control unit are set to IR channel 0 both DIP switches down then the Extender for HDMI ELR with PoL 2 over CAT5 must also be set to IR channel 0 See page 15 for information on how to change the IR channel on the Extender for HDMI ELR with PoL 2 over CAT5 N WARNING Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to the instructions CONNECTING THE EXTENDER FOR HDMI ELR WITH POL 2 OVER CAT5 Connect the Hi Def source to the Sender unit using the included HDMI cable Optionally connect a secondary Hi Def source to the Receiver unit Connecting a secondary Hi Def source to the Receiver unit provides the ability to switch between the a Hi Def source connected to the Sender unit and the Hi Def source connected to the Receiver unit In this way the Extender for HDMI ELR with PoL 2 over CAT5 functions as both a 2x1 Switcher and an Extender Use an HDMI cable to connect the HDTV display to the Receiver unit Connect the Ethernet device router to the Ethernet input port on the Sender unit using a CAT 5 CAT 5e or CAT 6 cable Connect the Ethernet output port on the Receiver unit to the remote device router with a CAT 5 CAT 5e or CAT 6 cable Use a CAT 5 or CAT 6 cable up to 330 feet 100 meters to connect the Link ports on both the Sender unit and Receiver unit O NOTE If terminating network cables in the
6. able is also recommended It is recommended to use one continuous run from one end to the other In some cases connecting through a patch might not work 18 TROUBLESHOOTING Cable recommendations Solid core CAT 5e cable rated at 350 MHz and terminated in 568a or 568b is the minimum requirement For resolutions greater than 1280x1024 or 1080i Gefen recommends solid shielded CAT 6 cables No video Make sure that DIP switch 2 on the Sender unit is set to the OFF position Also make sure that both DIP switch 6 and 7 on the Receiver unit is set to the OFF position If either of these DIP switches are in the ON position External Boot Loader Enable see page 14 and 17 then the Sender unit or Receiver unit will not function as an extender Next make sure that the CAT 5 cable connecting the Sender unit and Receiver unit is connected to the LINK port If this does not solve the issue try disconnecting and then reconnecting the AC power cord from the Sender unit Also verify that both units are working with short CAT 5e cables 15 20 feet Intermittent loss of video Flickering or a blinking image is the result of a loss of sync between the display and the source Try lowering the source resolution e g from 1080p to 720p If this solves the issue then the CAT 5 cables being used to connect the Sender unit and the Receiver unit are unable to handle the bandwidth of the higher resolution and thus you are losing sync Replace the exist
7. al device is turned off or disconnected The Select button on the Receiver unit can be used to manually switch between the remote and local inputs An optional IR Remote Control Unit Gefen part no RMT 2IR can also be purchased to switch between the remote input and the local input on the Receiver unit The GefenPRO Extender for HDMI ELR PoL 2 over CAT5 extends a Hi Def source with multichannel digital audio at resolutions of up to 1080p Full HD to 330 feet 100 meters using one CAT 5 cable The Extender for HDMI ELR PoL 2 over CAT5 extends Ethernet and provides an RS 232 and IR back channel to control A V sources using the same CAT 5 cable extension The built in IR Blaster allows you to point the IR remote s at the display to control the Hi Def sources as if they were located in the same room How lt Works The GefenPRO Extender for HDMI ELR PoL 2 over CAT5 Sender unit is located next to a set top box or DVD player source Use the supplied HDMI cable to connect an HDMI source to the Sender unit The GefenPRO Extender for HDMI ELR PoL 2 over CAT5 Receiver unit is located up to 330 feet away near the display Connect the HDTV display and another Hi Def source to the Receiver unit One CAT 5 cable connects the Sender and Receiver units to each other The Ethernet ports on both the Sender and Receiver units are connected to standard network devices such as 100Base T routers and hubs Multichannel digital audio is embedded in the HDMI signal
8. ch 1 EDID mode is set to the OFF position 15 DIP SWITCH CONFIGURATION Receiver Unit DIP Switch 6 Field upgrade Mode Default OFF ON Enable Field Upgrade Mode Cortex chip Allows the firmware to be upgraded on the Receiver unit If DIP switch 6 and or 7 are in the ON position RS 232 cannot be extended See page 15 for details on upgrading the firmware OFF RS 232 Pass Through Use when extending RS 232 between the Sender unit and the Receiver unit DIP switch 6 and 7 must be set to the OFF position for normal operation of the Extender for HDMI ELR with PoL 2 over CAT5 DIP Switch 7 Field Upgrade Mode Default OFF ON Enable Field Upgrade Mode VALENS chip Allows the firmware to be upgraded on the Receiver unit If DIP switch 6 and or 7 are in the ON position RS 232 cannot be extended See page 15 for details on upgrading the firmware OFF RS 232 Pass Through Use when extending RS 232 between the Sender unit and the Receiver unit DIP switch 6 and 7 must be set to the OFF position for normal operation of the Extender for HDMI ELR with PoL 2 over CAT5 DIP Switch 8 Green Mode Default OFF OFF Enable Green Mode When DIP switch 1 on the Receiver Unt is set to the OFF position the Receiver Unit is placed in Green Mode In this mode the unit is not powered unless 5V is detected on pin 18 of the HDMI cable Green Mode consumes less than 1 Watt of power ON Disable Green Mode If DIP
9. de the unit is not powered unless 5V is detected on pin 18 of the HDMI cable Green Mode consumes less than 1 Watt of power ON Disable Green Mode If DIP switch 1 is set to the ON position then the Sender Unit is always powered NOTE Both the Sender Unit and Receiver Unit must be placed in Green Mode in order to use the Green Mode feature 12 DIP SWITCH CONFIGURATION Sender Unit DIP Switch 2 Field Upgrade Mode Default OFF e ON Enable Field Upgrade Mode VALENS chip Allows the firmware to be upgraded on the Receiver unit If DIP switch 6 and or 7 are in the ON position RS 232 cannot be extended See page 15 for details on upgrading the firmware e OFF RS 232 Pass Through Use when extending RS 232 between the Sender unit and the Receiver unit DIP switch 6 and 7 must be set to the OFF position for normal operation of the Extender for HDMI ELR with PoL 2 over CAT5 13 DIP SWITCH CONFIGURATION Receiver Unit The Extender for HDMI ELR with PoL 2 over CAT5 contains eight DIP switches on the bottom of the Receiver Unit Each of these DIP switch performs a different function DIP switches located on the bottom of the Receiver Unit DIP Switch 1 EDID Mode Default OFF e ON Pass Through Mode DDC and HPD are passed through Both the connection status and the full video capabilities of the monitor are used by the source device e OFF Local EDID Mode Local EDID is used instead of the EDI
10. e 1 3 5 mm mini stereo jack Power Supply Senden 100 240VAC Power Output Connector Receiver sss eee eee ee ee 5 V 2 5 A DC locking Operating Temperature eee ee eee ee 0 C 50 2F 3 F Storage Temperature eee e eee 20 C 60 C 4 F 140 F Humidity Range sss sese ee 20 90 RH no condensation Dimensions Sender Receiver eee eee eee 8 4 W x 1 7 H x 6 7 D Shipping VV O1 0 EE EE EE 8 Ibs 20 WARRANTY Gefen warrants the equipment it manufactures to be free from defects in material and workmanship If equipment fails because of such defects and Gefen is notified within two 2 years from the date of shipment Gefen will at its option repair or replace the equipment provided that the equipment has not been subjected to mechanical electrical or other abuse or modifications Equipment that fails under conditions other than those covered will be repaired at the current price of parts and labor in effect at the time of repair Such repairs are warranted for ninety 90 days from the day of reshipment to the Buyer This warranty is in lieu of all other warranties expressed or implied including without limitation any implied warranty or merchantability or fitness for any particular purpose all of which are expressly disclaimed 1 Proof of sale may be required in order to claim warranty 2 Customers outside the US are responsible for shipping charges to and from Gefen 3 Copper cables are li
11. ender unit Receiver unit Firmware Update Network Cable Wiring Diagram Troubleshooting Specifications Warranty INTRODUCTION Congratulations on your purchase of the Extender for HDMI ELR PoL 2 over CAT5 Your complete satisfaction is very important to us GefenPRO In the realm of video distribution certain features are invaluable in a commercial or broadcast environment Accommodations such as a build in power supply and flat black rack mount enclosures set GefenPRO apart from our traditional products Complex distribution units allow for professional DVI 3G SDI and HDMI signals to be routed and converted easily and seamlessly while being backed up by a renowned and dependable technical support team Gefen invites you to explore the GefenPRO product line and hopes that you find the solution that fits your needs The GefenPRO Extender for HDMI ELR with PoL 2 over CAT5 The GefenPRO Extender for HDMI ELR PoL 2 over CAT5 does everything that the GefenPRO Extender for HDMI ELR with PoL over CAT5 does but adds active source switching with an additional Hi Def input on the Receiver unit This feature provides the capability to switch between the remote Hi Def source connected to the Sender unit and a local source connected to the Receiver unit If a new source is connected to the Receiver unit and turned on the Receiver unit will automatically switch to the local input The Receiver unit will revert to the remote input once the loc
12. gement for rapid integration of source and display devices e Built in IR Blaster allows IR remote control of source devices from remote viewing location e Internal 110 220 V AC Power Supply e BV DC 2 5 A Locking Power Supply output connector on Receiver unit e Rack mountable with optional Gefen EXT RACK 1U Rack Shelf Package Includes 1 Extender for HDMI ELR with PoL 2 over CATS Sender unit 1 Extender for HDMI ELR with PoL 2 over CAT5 Receiver unit 1 6 ft HDMI locking cable M M 2 Sets of Rack Ears 1 AC power cord 1 Quick Start Guide SENDER UNIT LAYOUT Front SN PRO Back SENDER UNIT DESCRIPTIONS Power This 2 color LED indicator will glow bright RED when there is no HDMI source connected and will glow bright GREEN when an HDMI source is present 110 220 V AC Connect the included AC power cord to this power receptacle Fuse Drawer Each power receptacle houses a fuse drawer The fuse drawer contains an active fuse and a spare fuse Both fuses are 250 V Power Switch Turn the power ON or OFF using this switch IR Blaster Connect an IR Blaster cable Gefen part no EXT 2IREMIT from this port to the Hi Def source to control the source from the viewing location RS 232 This RS 232 serial port is used to update the Receiver unit firmware Ethernet Connects the Sender unit to the network using Ethernet cabling Link Connects the Sender unit to the Receiver unit using CAT 5 cabl
13. ing HDMI In Connect a Hi Def source to this locking HDMI port using the included HDMI cable RECEIVER UNIT LAYOUT Front 1 2 3 4 Back 6 7 8 9 10 11 RECEIVER UNIT DESCRIPTIONS Local This LED indicator will glow bright green when the Receiver unit is switched to use the Local HDMI input Select Switches between the HDMI input on the Sender unit and the Local HDMI In port on the Receiver unit IR This IR window receives signals from the Hi Def source IR remote control The IR signals are sent back to the source device when using an IR Blaster on the Sender Power This 2 color LED indicator will glow bright RED when there is no HDMI source connected and will glow bright GREEN when an HDMI source is present 5V DC Out Connect an optional locking Gefen part no CAB PWR O6LL or non locking Gefen Part no CAB PWR O6NL power cord to this the included 5 V DC locking power supply connector to power additional devices Ext IR Connect an IR Extender Gefen part no EXT RMT EXTIR cable from this port to the Hi Def source to extend the IR control RS 232 This RS 232 serial port is used to update the Receiver unit firmware Ethernet Connects the Receiver unit to the network device Link Connects the Receiver unit to the Sender unit using CAT 5 cabling HDMI Out Connect an HDTV display or other output device to this locking HDMI port Local HDMI In Connect a secondary Hi Def source device to this locki
14. ing CAT 5 cables with a shielded CAT 6 cable Electromagnetic Interference EMI from fluorescent lights generators and A C unit motors can also cause intermittent loss of video Shielded CAT 6 cable with the drain wire soldered to the connectors will resolve the issue Also make sure to eliminate any patch panels and wall plates Patch panels and wall plates are prone to EMI if they are not shielded properly Image is tinted green or pink An image that is tinted green or pink is the result of the incorrect color space being transmitted Make sure that the display and source both support the same color space Setting DIP switch 1 on the Receiver unit to the OFF position will use the Local EDID EDID features newer than HDMI 1 3 are removed when the display is read This provides a general EDID which is compatible with more displays 19 SPECIFICATIONS Maximum Pixel Clock vn 225 MHz deta A 1 2V p p INPUT DDO Jarre 5V p p TTL HDMI Input Connector Sender Receiver 1 19 pin Type A female HDMI Output Connector Receiver sss sse ee eee eee 1 19 pin Type A female RS 232 Connector Sender sss eee 1 DB 9 female RS 232 Connector Receiver se eee eee 1 DB 9 male Ethernet Connector Sender Receiver esse eee ee 1 RJ 45 shielded Link Connectors Sender Receiver sese eee eee eee 1 RJ 45 shielded IR Blaster connector Sender sees 1 3 5 mm mini mono jack IR Extender connector Receiver see eee ee
15. mited to a 30 day warranty and cables must be in their original condition The information in this manual has been carefully checked and is believed to be accurate However Gefen assumes no responsibility for any inaccuracies that may be contained in this manual In no event will Gefen be liable for direct indirect special incidental or consequential damages resulting from any defect or omission in this manual even if advised of the possibility of such damages The technical information contained herein regarding the features and specifications is subject to change without notice For the latest warranty coverage information refer to the Warranty and Return Policy under the Support section of the Gefen Web site at www gefen com PRODUCT REGISTRATION Please register your product online by visiting the Register Product page under the Support section of the Gefen Web site 21 x N AGE EH DL AT BE LR POL 2x 1 800 545 6900 20600 Nordhoff St Chatsworth CA 91311 818 772 9100 www gefenpro com support gefenpro com Rev A5 fax 818 772 9120
16. ng HDMI port IR REMOTE CONTROL RMT 2IR Remote Control not included Activity Indicator This LED will be activated momentarily each time a button is pressed Input Source Selection Buttons 1 2 These buttons function the same as the Select button on the Receiver unit Press button 1 to switch to the remote input source connected to the Sender unit Press button 2 to switch to the local input source connected to the Receiver unit IR Codes ASCII Corresponding Binary RMT 2IR Button NOTE An Activity Indicator that flashes quickly while holding down any one of the 16 buttons indicates a low battery Replace the IR Remote Control battery as soon as possible IR REMOTE CONTROL Installing the Battery The Remote Control unit ships with two batteries One battery is required for operation and the other battery is a spare 1 Remove the battery cover on the back of the IR Remote Control unit 2 Insert the included battery into the open battery slot The positive side of the battery should be facing up 3 Replace the battery cover Channel 0 default Remote Channel 1 ON ON a gt VL p U A N r ry f RO E J 1 pa j f har Y N 4 Y Remote Channel 2 Remote Channel 3 ON ON pr 122 Setting the IR Channel The IR channel on the IR Remote Control must match the IR channel used by the Extender for HDMI
17. switch 1 is set to the ON position then the Receiver Unit is always powered NOTE Both the Sender Unit and Receiver Unit must be placed in Green Mode in order to use the Green Mode feature FIRMWARE UPDATE Firmware Update Procedure The latest firmware update can be found on the Gefen Web site under Support gt Downloads Sender Unit 1 Set DIP switch 1 and 2 on the Sender unit to the ON position 2 Connect an RS 232 cable from the Sender unit to the computer containing the firmware 3 Reboot the Sender unit by disconnecting and reconnecting the power supply 4 Runthe BAT file to begin the update process 5 After the firmware update process has completed return DIP switch 1 and 2 to the OFF position Receiver Unit 1 Set DIP switch 7 and 8 on the Receiver unit to the ON position 2 Connect a null modem RS 232 cable from the Receiver unit to the computer containing the firmware 3 Reboot the Receiver unit by disconnecting and reconnecting the power supply 4 Run the BAT file to begin the update process 5 After the firmware update process has completed return DIP switch 7 and 8 to the OFF position 17 NETWORK CABLE WIRING DIAGRAM Gefen recommends the TIA EIA 568 B wiring option Please adhere to the table below when field terminating cable for use with Gefen products CAT 5 CAT 5e and CAT 6 cabling comes in stranded and solid core types Gefen recommends using solid core cabling CAT 6 c