BlueWalker PowerWalker VI 650 LCD/UK
Contents
1. to avoid a full battery discharge e Please do not use the UPS in excess of the rated load capacity e The UPS contains one two large capacity batteries So the shell shall not be opened otherwise such dangers as electric shock will be caused If any internal overhaul or replacement of the battery is required please contact the distributor e The internal short circuiting of the UPS will lead to dangers such as electric shock or fire therefore no water containers such as a water glass shall be placed on the top of the UPS so as to avoid such dangers as electric shock e Do not dispose of battery or batteries in a fire The battery may explode e Do not open or mutilate the battery or batteries Released electrolyte is harmful to the skin and eyes It may be toxic e Icon on the rating label stands for phase symbol e A battery can present a risk of electrical shock and high short circuit current The following precautions should be observed when working on batteries e Remove watches rings or other metal objects from the hand o Use tools with insulated handles E Powertvalker e Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries EI e When replacing batteries replace with the same type and number of the sealed lead acid batteries e The maximum ambient temperature rating is 40 C e This pluggable
2. QO PowerWalker Line Interactive UPS PowerWalker VI 650 LCD UK PowerWalker VI 850 LCD UK PowerWalker VI 1000 LCD UK PowerWalker VI 1500 LCD UK PowerWalker VI 2000 LCD UK Quick Start Guide O E PowerWalker IMPORTANT SAFETY INSTRUCTIONS ER SAVE THESE INSTRUCTIONS This manual contains important instructions for models PowerWalker VI 650 850 1000 1500 2000 LCD UK that should be followed during installation and maintenance of the UPS and batteries e This product is specially designed for PCs and it is not recommended for use in any life supporting system and other specific important equipment e This equipment can be operated by any individual with no previous training e Do not plug household appliances such as hair dryers to UPS receptacles e This unit intended for installation in a controlled environment temperature controlled indoor area free of conductive contaminants Avoid installing the UPS in locations where there is standing or running water or excessive humidity e Risk of electric shock do not remove cover No user serviceable parts inside Refer servicing to qualified service personnel e The utility power outlet shall be near the equipment and easily accessible To isolate UPS from AC input remove the plug from the utility power outlet e If UPS is to be stored for a long time it is recommended to recharge the batteries by connecting the utility power to UPS switch ON once a month for 24 hours
3. TPUT fi z Batt MODE OF Input voltage 12 Output voltage AC mode indicator Front Panel LCD panel Load level indicator flashing indicates overload Power switch Battery capacity indicator flashing O Battery mode indicator indicates low battery Back Panel VI 650 850 LCD UK VI 1000 LCD UK VI 1500 2000 LCD UK Output receptacles 12 AC input Modem or phone surge protection O USB port Output receptacles 9 AC input Circuit breaker O Modem or phone surge protection USB port Output receptacles 2 AC input Circuit breaker 4 Modem or phone surge protection USB port O E PowerWalker 4 Installation and Initial Startup ER A Before installation please inspect the unit Be sure that nothing is damaged I Placement amp Storage Conditions Install the UPS in a protected area that is free of excessive dust and has adequate air flow Please place the UPS away from other units at least 20 cm to avoid interference Do NOT operate the UPS where the temperature exceeds 0 40 C and the humidity is over 0 90 RH OD Power Walker 20cm E 20cm e Il Connect to Utility and Charge Plug in the AC input cord to the wall outlet For the best results we suggest charging the battery at least 4 hours before initial use The unit charges its battery while connecting to the utility Ill Connect the Loads Plug in the l
4. e time arises to throw away your product please recycle all the components possible Batteries and rechargeable batteries are not to be disposed in your domestic waste Please recycle them at your local recycling point Together we can help to protect the environment CES E O E Poner Walker 1 Introduction EN PowerWalker VI series is an intelligent and compact line interactive UPS Uninterruptible Power Supply which is designed to protect your personal computer or sensitive electronic equipments from all forms of power interference including complete power failures It is equipped with many features that allow any attached equipment to operate longer and more reliability 2 Green concept design PowerWalker VI 650 850 1000 1500 2000 LCD UK series adopt switching mode charging which creates a variety of benefits e Increases charging efficiency to more than 80 more energy saving than traditional UPS e The battery requires only 4 hours to be 90 charged reducing 50 of charging time e Reduces heat generation during battery charging providing a longer battery life e Increases reliability and helps to save money 3 Package Contents You should have received the following items inside of package S i 23 Vi aa UPS Unit USB Cable IEC Cable for VI 650 850 LCD UK only Software CD Quick Start Guide Service Guide E Poner Walker 4 Product Overview LCD Panel EJ o 988 39 8889 INPUT OU
5. ith UPS has been established and an orange icon will appear in the system tray e Double click the icon to use the monitor as above o You can schedule UPS shutdown start up and monitor UPS status through PC e Detail instructions please refer to the e manual in the software O E PowerWalker 8 Specifications Mel SOLCD UK BSOLCD UK Voltage Range Frequency Range Voltage Regulation Transfer Time Waveform Protection Short circuit and overload protection Type amp Number 12V 9Ah x 1 Charging Time Protection Backup Time est 120W 15 min LCD Indicator Dimension DxWxH Humidity Noise Level VI 1000 LCD UK VI 1500 LCD UK VI 2000 LCD UK CAPACITY 1000 VA 600 W 1500 VA 900 W 2000 VA 1200 W INPUT Voltage Voltage Range Frequency Range OUTPUT Voltage Regulation Frequency Range Transfer Time Waveform BATTERY Type amp Number 12V 9Ah x 2 Charging Time 4 6 hours recover to 90 capacity Protection Overload discharge and overcharge protection Backup Time est 240W 18 min 20 min LCD Indicator Dimension DxWxH 0 90 RH 0 40 C non condensing 220 230 240 VAC 162 290 VAC 50 60 Hz Auto sensing 10 50 or 60 Hz 1 Hz Typical 2 6 ms 10 ms max Simulated Sine Wave 12V 9Ah x 2
6. oads to output receptacles on the rear panel of the UPS Simply turn on the power switch of UPS unit and devices connected to the UPS will be protected by UPS unit A Do not attach a power strip or surge suppressor to the UPS IV Connect Modem or Phone for Surge Protection Connect a single modem or phone line into surge protected IN outlet on the back panel of the UPS unit Connect from OUT outlet to the computer with another phone line cable V Connect USB Cable To monitor the UPS status such as unattended UPS shutdown and start up by using bundled software please connect the UPS and PC with USB cable included E MEL A NEVER connect a laser printer or scanner to the UPS unit because in rush current generated by motor s devices may cause the damage of the unit VI Turn On Off the Unit Turn on the UPS unit by pressing the power switch Turn off the UPS unit by pressing again the power switch 6 Audible alarm from the UPS o When UPS switches from AC mode to Battery Mode to back up power supply sounding every 10 seconds When battery is low sounding every second When UPS is overloaded sounding every 0 5 second When battery is faulty sounding every 2 seconds Other fault Continuous sounding 7 Software Installation on your PC o Use the bundled CD and follow the on screen instructions to install the software ViewPower e After the software is successfully installed the communication w
7. type A equipment with battery already installed by the supplier is operator installable and may be operated by laymen e During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3 5mA e Attention hazardous through electric shock Also with disconnection of this unit from the mains hazardous voltage still may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole of the battery when maintenance or service work inside the UPS is necessary e The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible e In case smoke is found coming out from the device please cut off the power supply quickly and contact the distributor e Do not keep or use this product in any of the following environments o Any area with combustible gas corrosive substance or heavy dust o Any area with extraordinarily high or low temperature above 40 C or below 0 C and humidity of more than 90 o Any area exposed to direct sunshine or near any heating apparatus o Any area with serious vibrations o Outdoor e Inthe event that there is fire occurring in the vicinity please use dry power extinguishers The use of liquid extinguishers may give rise to the danger of electric shock This product complies with the safety and environmental regulations in EU If th
Download Pdf Manuals
Related Search
Related Contents
Kingston Technology ValueRAM 16GB DDR3-1600 Tripp Lite MODBUS Management Accessory Card for UPS Remote Monitoring and Control 슬라이드 1 - The Dashcam Store Redbooks - Lotus software MPT 400 Operating Instructions parpp3d++ - Featflow Philips Dump box HD5088 Handbuch - HiFi Renesas Starter Kit for RL78/G13 Software Help Manual (IAR Copyright © All rights reserved.