Home

DELL PowerEdge R210 II

image

Contents

1. Base Management iDRAC6 Feature Functionality iDRAC6 Express Enterprise vFlash Media Power capping Y Y Y Last crash screen Y Y Y capture Boot capture Y Y Y Serial over LAN Y Y Y Virtual media Y Y Virtual console Y Y Virtual console Y Y sharing Virtual flash Y Monitoring Sensor Monitoring Y Y Y Y and Alerting Real time Power Y Y Y Y Monitoring Real time Power Y Y Y Y Graphing Historical Power Y Y Y Y Counters Logging Features System Event Log Y Y Y Y RAC Log Y Y Y Trace Log Y Y PowerEdge R210 Il Technical Guide 49 Dell 17 Peripherals The PowerEdge R210 Il supports the following USB devices DVD bootable requires two USB ports USB key bootable Keyboard only one USB keyboard is supported Mouse only one USB mouse is supported PowerEdge R210 II Technical Guide 50 Dell Appendix A Statement of Volatility The Dell PowerEdge R210 Il contains both volatile and non volatile NV components Volatile components lose their data immediately upon removal of power from the component Non volatile components continue to retain their data even after the power has been removed from the component Components chosen as user definable configuration options those not soldered to the motherboard are not included in the Statement of Volatility Configuration option information pertinent to options such as microprocessors system memory remote access controllers and storage controllers is available
2. 7 3 DIMM Slots The PowerEdge R210 Il has 4 DIMM slots for memory supporting up to 2 DIMMs per channel 7 4 Speed The memory frequency is determined by a variety of inputs e Speed of the DIMMs e Speed supported by the processor e Configuration of the DIMMs The memory speed of each channel depends on the memory configuration e For single rank memory modules o One memory module per channel supports up to 1333 MHz o Two memory modules per channel supports up to 1333 MHz 26 PowerEdge R210 II Technical Guide Dell e For dual rank memory modules o One memory module per channel supports up to 1333 MHz o Two memory modules per channel supports up to 1066 MHz If memory modules with different speeds are installed they will operate at the speed of the slowest installed memory module s 7 5 Sparing Memory sparing is not supported 7 6 Mirroring Memory mirroring is not supported 7 7 RAID Memory RAID is not supported 7 8 Supported Configurations Supported memory configurations for the R210 II are listed in Table 10 For the latest information on memory options visit Dell com Table 10 Supported Configurations Lp DIMM DIMM nee pps Memory Number ire GB Quantity Type MHz MHz Channel of Ranks Width 1 1 UDIMM 1333 1333 1 1 x8 2 1 UDIMM 1333 1333 1 1 x8 2 2 UDIMM 1333 1333 2 1 x8 4 2 UDIMM 1333 1333 2 1 x8 4 4 UDIMM 1333 1333 2 1 x8 4 1 UDIMM 1333 1333 1 2 X8 8 4 UDIMM 1
3. DIMM temperature inlet ambient temperature and system configurations The thermal management adjusts proper cooling ability for the system according to what the system really needs Optimized Ventilation The R210 Il chassis has a custom ventilation design for optimized air flow path Each component and peripheral is ensured sufficient air for cooling 5 7 Acoustics The acoustical design of the PowerEdge R210 II reflects the following Adherence to Dell s high sound quality standards Sound quality is different from sound power level and sound pressure level in that it describes how humans respond to annoyances in sound like whistles and hums One of the sound quality metrics in the Dell specification is the prominence ratio of a tone which is listed in Table 6 Office environment acoustics Compare the values for LpA in Table 6 and note that they are lower than ambient measurements of typical office environments 21 PowerEdge R210 II Technical Guide Dell e Hardware configurations affect system noise levels Dell s thermal control provides for cooling flexible to varying hardware configurations Acoustical performance associated with two common configurations is listed in Table 6 e Noise ramp and descent at boot Fan speeds and corresponding noise levels ramp up during the boot process to add a layer of protection for component cooling in the event that the system does not boot properly The acoustical performance for minim
4. Both also support a generic mounting interface for tooled mounting in threaded hole and 2 post Telco racks Screws are not included in either kit because threaded racks are offered with a variety of thread designations Table 17 Supported Racks Rack Types Supported EXCITA puru R210 II Mite The A6 rail system also supports a cantilever ear mounting option although it is not recommended since it does not support shipment of the server in the rack and allows the position of the server to exceed its designated U space The key difference between the A4 and A6 rail systems is the overall length of the rail members The A6 rail system which is the default rail system being offered with the R210 Il is the shorter of the two and is well suited for mounting in 2 post racks or in 4 post racks with mounting flanges that are spaced in the 500 760 mm range The A4 rail system is longer and can be used for mounting in 4 post racks with mounting flanges that are spaced in the 600 890 mm range See Table 18 for specific adjustment range information on each rail system Table 18 Rail Adjustability Ranges and Depth Rail Adjustability Range Rail Depth Mounting Rail imm ud Product Interface Type Square Round Threaded without with Min Max Min Max Min Max CMA CMA eneric Rear als 5081 751 4941 744 5191 762 Generic R210 II With middle brackets removed With rear brackets removed applies to 2 post or cantilev
5. Drives The R210 Il supports one SATA interface DVD ROM or DVD RW 12 5 Tape Drives External tape drives and tape libraries are supported No internal tape drive support is available For more information on supported tape drives and tape libraries see Dell com Storage 39 PowerEdge R210 II Technical Guide Dell 13 Video The PowerEdge R210 Il includes a Matrox G200eW with 8 MB memory integrated in Winbond WPCM450 BMC controller The resolutions supported are listed in Table 16 Table 16 Graphics Video Modes Resolution Refresh Rate Hz o 640 x 480 60 72 75 85 8 16 32 800 x 600 60 72 75 85 8 16 32 1024 x 768 60 70 75 85 8 16 32 1280 x 1024 60 75 85 8 16 1280 x 1024 60 32 PowerEdge R210 Il Technical Guide 40 Dell 14 Rack Information 14 1 Overview The ReadyRails static rail systems for the R210 II provide toolless support for racks with square or unthreaded round mounting holes including all generations of Dell racks The rail systems also offer tooled mounting support for 4 post threaded and 2 post Telco racks for added versatility See Table 17 for the list of supported rails and racks 14 2 Rails Two different static rail systems are available for the R210 Il the A4 rail system and the A6 rail system Both support toolless mounting in 19 wide EIA 310 E compliant square hole and unthreaded round hole racks using the ReadyRails mounting interface
6. H800 PERC S100 software RAID PERC S300 software RAID PERC H200 PERC H800 available Q4 2011 Feature R210 R210 Il R310 Optional Storage Non RAID Non RAID Non RAID Controller SAS 5 E 6Gb s SAS HBA SAS 5 E LSI 2032 for tape RAID LSI 2032 for tape backup unit only 6Gb s SAS HBA RAID SAS 6 iR PERC 6 E SAS 5 E PERC S300 software RAID PERC H200 PERC H700 PERC H800 Availability ECC memory quad pack LED diagnostic add in RAID TPM CTPM ECC memory quad pack LED diagnostic add in RAID TPM CTPM available Q3 2011 ECC memory hot plug hard drives redundant power supplies quad pack LED diagnostic or LCD with hot plug hard drive chassis TPM internal Server Mgt BMC IPMI 2 0 compliant BMC IPMI 2 0 compliant BMC IPMI 2 0 compliant full Dell OpenManage full Dell OpenManage suite full Dell OpenManage suite suite Optional iDRAC6 Express Optional iDRAC6 Express Optional iDRAC6 iDRAC6 Enterprise vFlash iDRAC6 Enterprise vFlash Express iDRAC6 media media Enterprise vFlash media 1 0 Slots 1 x PCle x16 1 x PCle x16 1 x PCle x16 x8 routing 1 x PCle x8 x8 routing 1 x PCle x8 x4 routing RAID See RAID options in See RAID options in chapter See RAID options in chapter chapter 12 12 12 NIC LOM 2 x GbE LOM 2 x GbE LOM 2 x GbE LOM USB 2 front 2 back 2 2 front 2 back 2 internal 2 front 2 back 2 internal Power Supplies Non redundant 250W 8
7. INTRUDER signal 30 PowerEdge R210 II Technical Guide Dell 8 16 System Management Bus SMBus 2 0 The chipset contains an SMBus Host interface that allows the processor to communicate with SMBus slaves This interface is compatible with most I2C devices Special 12C commands are implemented The chipset s SMBus host controller provides a mechanism for the processor to initiate communications with SMBus peripherals slaves Also the chipset supports slave functionality including the Host Notify protocol Hence the host controller supports eight command protocols of the SMBus interface The chipset s SMBus also implements hardware based Packet Error Checking for data robustness and the Address Resolution Protocol ARP to dynamically provide address to all SMBus devices 8 17 Intel Virtualization Technology for Directed 1 0 The chipset provides hardware support for implementation of Intel Virtualization Technology with Directed 1 0 Intel VT d Intel VT d Technology consists of technology components that support the virtualization of platforms based on Intel Architecture Processors Intel VT d Technology enables multiple operating systems and applications to run in independent partitions A partition behaves like a virtual machine VM and provides isolation and protection across partitions Each partition is allocated its own subset of host physical memory 31 PowerEdge R210 II Technical Guide Dell 9 BIOS 9 1 Overview The R
8. Specification Operating Requirements Non Operating Requirements Temperature Ranges 10 C to 35 C for altitude lt 900m or 2952 75ft 50 F to 95 F 40 C to 65 C Temperature Ranges 10 C to T C 40 F to 149 F for altitude gt 900m or 2952 75ft 50 F to T F T ture Gradient emperi ure Gra En 10 C 20 C maximum per 60 minutes Humidity Percent Ranges a0 10 POR PRNO RIR noncondensing maximum wet bulb maximum wet bulb s temperature 29 C temperature 38 C Humidity Gradient m ity Gradien 10 10 maximum per 60 minutes Low Limits E Tode 15 2m 15 2m Altitude Ranges Hier iis 10 000ft 35 000ft s 3048m 10 668m Use the formulas in Figure 9 to calculate the maximum operating temperature in C for a given altitude Use the first formula if the altitude is stated in meters use the second formula if the altitude is stated in feet Use the formulas in Figure 10 to calculate the maximum operating temperature in F for a given altitude Use the first formula if the altitude is stated in meters use the second formula if the altitude is stated in feet Maamum Altitude n meters 900 ec 300 034 25 Madimum Alttude n M 2952 75 e r r 4 iY 4 Figure 9 Formulas for Maximum Operating Temperature for Given Altitude C lein ft 2952 75 8 in it oF f Maximum Altituc l 084 25 d M aximum Altitude in meters 900 1x1 8 i 300 95 F or 95 F
9. Weighted sound pressure level The system is placed in center of 1507779 table while the acoustic transducer is located 150 cm above the floor and 50 cm in front of the equipment Prominent tones Criteria of D 6 and D 11 of ECMA 74 11th ed 2010 are followed to determine if discrete tones are prominent The system is placed in a rack with its bottom at 75 cm from the floor The acoustic transducer is at front bystander position ref 1507779 3rd 2010 Section 8 6 2 23 PowerEdge R210 II Technical Guide Dell 6 Processors 6 1 Overview The processors for the R210 Il are based on the latest two and four core offerings from the Intel Xeon processor E3 1200 product family or the Intel Core processor i3 2100 product family series 6 2 Features Key features of the Intel Xeon processor E3 1200 product family or the Intel Core processor i3 2100 product family include New microarchitecture on 32nm process delivers higher performance and lower power Intel Advanced Vector Extensions AVX allows for better acceleration of floating point intensive applications Next generation Intel Turbo Boost Technology maximizes processor performance during workload spikes by allowing the processor to briefly operate above TDP New Advanced Encryption Standard AES provides improved encryption and decryption performance Increased processor performance of up to 25 over previous generation Memory and I O 2x memory footprint at 32GB 4
10. Xeon processor Intel Xeon processor E3 Intel Xeon processors 3400 3400 series Intel Celeron G1101 Intel Pentium G6950 Intel Core i3 processor 500 series 1200 product family Intel Core processor i3 2100 product family series Intel Celeron G1101 Intel Pentium G6950 Intel Core i3 processor 500 series Front Side Bus Direct Media Interface DMI 2 5Gb s Direct Media Interface II DMI 5 0Gb s Direct Media Interface DMI 2 5Gb s Sockets 1 1 1 Cores 2 or 4 2 or 4 2 or 4 L2 L3 Cache Up to 8MB Up to 8MB Up to 8MB Chipset Intel 3420 Intel C202 Intel 3420 DIMMs 4 DDR3 1066 1333MHz 4 DDR3 1333MHz 6 DDR3 1066 1333MHz Min Max RAM 1GB 32GB 1GB 32GB 1GB 32GB Hard Drive Bays ZA 3 5 or 2 x 3 5 or 4x 3 5 or 2x2 5 4 x 2 5 available Q2 2011 4 x 2 5 Optional hot plug Hard Drive Types SATA SSD SAS nearline SAS SATA SATA SSD SAS nearline SAS SATA SATA SSD SAS nearline SAS SATA External Drive Bay 1 for slim optical disk drive ODD 1 for slim optical disk drive ODD 1 for slim optical disk drive ODD Embedded Hard Drive Controller Chipset based SATA Chipset based SATA PERC 5100 embedded SW RAID Intel 3420 PERC S100 embedded SW RAID PowerEdge R210 Il Technical Guide Dell backup unit only RAID SAS 6 iR PERC 6 E PERC S100 software RAID PERC S300 software RAID PERC H200 PERC
11. additional PCle lanes 20 Storage 6 SATA 3Gb s ports Efficiency Low power Intel Xeon processor options Reliability Error Correcting Code ECC memory to improve data integrity Server validation With server operating systems server class peripherals and adapters to ensure compatibility Storage RAID support for Linux operating systems 6 3 Supported Processors Processors supported on the R210 ll are listed in Table 7 and Table 8 For the most up to date listings see Dell com Table 7 Supported Intel Xeon Processors Model Speed Power Cores L3 Cache Threads Turbo Memory Process GHz Watts MB MHz E3 1280 3 50 95 4 8 8 Yes 1333 32nm E3 1270 3 40 80 4 8 8 Yes 1333 32nm E3 1240 3 30 80 4 8 8 Yes 1333 32nm E3 1230 3 20 80 4 8 8 Yes 1333 32nm E3 1220 3 10 80 4 8 4 Yes 1333 32nm E3 1260L 2 40 45 4 8 8 Yes 1333 32nm E3 1220L 2 20 20 2 3 4 Yes 1333 32nm 24 PowerEdge R210 II Technical Guide Dell Table 8 Supported Intel Desktop Processors Model Speed Power Cores L2 L3 Cache Threads Turbo Memory Process GHz Watts MB MHz Intel Core 3 10 65 2 3 4 No 1333 32nm 13 2100 Intel Pentium 2 90 65 2 3 2 No 1333 32nm G850 Intel Pentium 2 60 65 2 3 2 No 1333 32nm G620 6 4 Processor Configurations The R210 Il is a single socket server and the memory controller embedded in the processor
12. and A6 rail systems in the 2 post flush mount configuration The rear brackets on both the A4 and the A6 rail systems can be removed and discarded in this configuration but the A4 rail system still provides the smaller mounting footprint A6 Rail System and discarded on both A4 and A6 A4 Rail System 1 Back brackets can be removed Figure 14 A4 and A6 Rail Systems in 2 post Flush Mount Configuration 43 PowerEdge R210 Il Technical Guide Dell 15 Operating Systems For detailed information see the following e Operating System Support Matrix for Dell PowerEdge Systems on Dell com e Dell PowerEdge R210 Il Getting Started Guide on Support Dell com PowerEdge R210 II Technical Guide 44 Dell 16 Systems Management 16 1 Overview Dell delivers open comprehensive and integrated solutions that help you reduce the complexity of managing disparate IT assets Combining Dell PowerEdge Servers with a wide selection of Dell developed systems management solutions gives you choice and flexibility so you can simplify and save in IT environments of any size To help you meet your server management demands Dell offers Dell OpenManage systems management solutions for e Deployment of one or many servers from a single console e Monitoring of server and storage health and maintenance e Update of system operating system and application software Dell offers IT management solutions for organizations of all sizes priced and si
13. of systems management for ease of deployment monitoring and ongoing maintenance 1 2 Key Benefits Designed for powerful and balanced performance the PowerEdge R210 II delivers e Built in Reliability Security and Energy Efficiency Built in redundant hard drives encryption security and data protection options lower wattage power supplies and ease of deployment e Business Value Performance headroom and capacity expansion allow the R210 II to grow as your business grows A choice of options enables you to tailor your R210 Il configuration to your compute requirements e Simplified Management Manage the R210 II with the full suite of Dell OpenManage systems management software throughout the server lifecycle e Better Performance with Less Noise Business performance with similar sound levels as a desktop computer to meet the needs of sound sensitive office environments 1 3 Flexible Secure Technology Securing your most valuable asset your data is important That is why the PowerEdge R210 II has data protection options to help keep your data as safe as possible Coupled with the latest version of Microsoft Windows Small Business Server 2011 SBS 2011 the PowerEdge R210 II provides an integrated solution that can further protect your data by providing automatic backup and restore functionality as well as offering email remote access and collaboration to help take your business to the next level The R210 Il also includes l
14. on the front panel board and is used to detect chassis intrusion When the cover is opened the switch circuit closes and indicates intrusion 4 12 7 Secure Mode BIOS has the ability to enter a secure boot mode through setup This mode includes the option to lock out the power and NMI switches on the control panel or set up a system password For more information see the Using the System Setup Program and Boot Manager chapter in the PowerEdge R210 Il Owner s Manual on Support Dell com 4 13 USB Key The PowerEdge R210 II supports two internal USB connectors which can be used for USB keys 4 14 Battery A replaceable coin cell CR2032 3V battery is mounted on the planar to provide backup power for the Real Time Clock and CMOS RAM on the Intel SP5100 chip 4 14 1 Field Replaceable Units FRU The planar contains a serial EEPROM to store Field Replaceable Unit FRU information including Dell part numbers part revision levels and serial numbers This information is used by the SEL system event log and the BMC baseboard management controller 4 15 User Accessible Jumpers Sockets and Connectors See the Jumpers and Connectors chapter in the PowerEdge R210 Il Owner s Manual on Support Dell com 18 PowerEdge R210 Il Technical Guide Dell 5 Power Thermal Acoustic 5 1 Power Supplies The base system includes a single 250W power supply This unit provides power to the planar the internal hard drive bays and one slim optical d
15. partition The vFlash Media delivers the following key features e Support for 8 GB SD storage media e Can be used as a repository for a pre OS image eliminating the need to maintain a network infrastructure for OS deployment 47 PowerEdge R210 II Technical Guide Dell e Can also be used for permanent diagnostics image for use after system failures or permanent failsafe image for periodic configuration changes A more detailed feature list for iDRAC6 Express iDRAC6 Enterprise and vFlash Media is shown in Table 20 Table 20 Features List for Base Management Functionality iDRAC6 and vFlash Base Management iDRAC6 Feature Functionality iDRAC6 Express Enterprise vFlash Media Interface and Standards Support IPMI 2 0 Y Y Y Y Web based GUI Y Y Y SNMP Y Y Y WSMAN Y Y Y SMASH CLP Y Y Y Racadm command Y Y line Conductivity Shared Failover Y Y Y Y Network Modes IPv4 Y Y Y Y VLAN Tagging Y Y Y Y IPv6 Y Y Y Dynamic DNS Y Y Y Y Dedicated NIC Y Y Security and Authentication Role based Y Y Y Y Authority Local Users Y Y Y Y Active Directory Y Y Y SSL Encryption Y Y Y Remote Management and Remediation Remote Firmware Y Y Y Y Update Server power Y Y Y Y control Serial over LAN Y Y Y Y with proxy Serial over LAN no Y Y Y proxy PowerEdge R210 Il Technical Guide 48 Dell
16. up to two SPI flash devices with speed up to 20 MHz 33 MHz utilizing two chip select pins 8 9 Compatibility Module The DMA controller incorporates the logic of two 82C37 DMA controllers with seven independently programmable channels Channels 0 3 are hardwired to 8 bit count by byte transfers and channels 5 7 are hardwired to 16 bit count by word transfers Any two of the seven DMA channels can be programmed to support fast Type F transfers Channel 4 is reserved as a generic bus master request The chipset supports LPC DMA which is similar to ISA DMA through the DMA controller LPC DMA is handled through the use of the LDRQ lines from peripherals and special encoding on LAD 3 0 from the host Single Demand Verify and Increment modes are supported on the LPC interface The timer counter block contains three counters that are equivalent in function to those found in one 82C54 programmable interval timer These three counters are combined to provide the system timer function and speaker tone The 14 31818 MHz oscillator input provides the clock source for these three counters The chipset provides an ISA Compatible Programmable Interrupt Controller PIC that incorporates the functionality of two 82C59 interrupt controllers The two interrupt controllers are cascaded so that 14 external and two internal interrupts are possible In addition the chipset supports a serial interrupt scheme All of the registers in these modules can be re
17. 0 Bronze auto ranging 100V 240V Non redundant 250W 80 Bronze auto ranging 100V 240V Non redundant 350W 80 Bronze Optional redundant 400W 80 Silver auto ranging 100V 240V Fans Non redundant non hot pluggable Non redundant non hot pluggable Non redundant non hot pluggable Form Factor 1U Rack 1U Rack 1U Rack PowerEdge R210 Il Technical Guide Dell 2 New Technologies New technologies on the Dell PowerEdge R210 II include the following New processors including the Intel Xeon processor E3 1200 product family and the Intel Core processor i3 2100 product family Improved acoustics in small offices or branch offices over the predecessor system PowerEdge R210 Shorter rack rail kits Front ear rack mounting option 1333 MHz 2 Gb based memory 8 GB UDIMMs SAS 6 Gbps HBA external controller More efficient power supply 89 available Q3 2011 2 Gb and 4 Gb memory DRAM technology Support for 3 5 3 TB nearline SAS 7 2K rpm hard drives available Q2 2011 Support for up to four 2 5 SSD or SAS hard drives available Q2 2011 PowerEdge R210 II Technical Guide 10 Dell 3 System Overview Table 2 Product Feature Summary Feature Technical Specification Form Factor 1U rack Quad core Intel Xeon processor E3 1200 product family Processors Dual core Intel Core processor i3 2100 product family Processor Sockets 1 FO
18. 210 II BIOS is based on the Insyde BIOS core which supports the following features Simultaneous Multi Threading SMT support PCI 2 3 compliant Plug and Play 1 0a compliant MP Multiprocessor 1 4 compliant Ability to boot from hard drive optical drive iSCSI drive USB key and SD card ACPI 2 0 support SO OS S4 S5 States PXE and WOL support for on board NICs SETUP access through F2 key at end of POST USB 2 0 USB boot code is 1 1 compliant F1 F2 error logging in CMOS Virtual KVM CD and floppy support iDRAC supported Unified Server Configurator UEFI 2 1 support Power management support including DBS Power Inventory and multiple Power Profiles o Maximum Performance o OS Control DBS o Custom SMBIOS 2 5 PCI to PCI bridge 1 0 compliant Dell Server Assistant 7 0 support System Service support Onboard PCI video BIOS support SATA enabled for CD ROM and hard drives PCI FW 3 0 compliant Selectable Boot support El Torito CD ROM Boot 1 0 Remote BIOS Update support Remote Configuration Interface RCI support Console redirection through COM1 PXE support based on Preboot Execution Environment Specification v2 1 2 byte ID support ePPID support in flash Memory remapping support DDR3 UDIMM memory support UEFI shell Support AC recovery staggering Power Up DIMM mismatch checking VT d The PowerEdge R210 II BIOS does not support the following e BIOS language localization BIOS recovery after bad
19. 333 1333 2 1 x8 8 2 UDIMM 1333 1333 2 2 x8 16 4 UDIMM 1333 1333 2 2 x8 16 2 UDIMM 1333 1333 2 2 X8 32 4 UDIMM 1333 1333 2 2 X8 27 PowerEdge R210 Il Technical Guide Dell 8 Chipset 8 1 Overview The PowerEdge R210 II planar incorporates the Intel C200 Series PCH chipset The features listed below are part of the chipset 8 2 Direct Media Interface Direct Media Interface DMI is the chip to chip connection between the processor and C200 series chipset This high speed interface integrates advanced priority based servicing allowing for concurrent traffic and true isochronous transfer capabilities Base functionality is completely software transparent permitting current and legacy software to operate normally 8 3 PCI Express Interface The C200 series provides up to 8 PCI Express root ports Each root port supports 5GT s bandwidth PCI Express Root Ports 1 4 can be statically configured as four x1 ports or ganged together to form one x4 port Ports 5 and 6 can only be used as two x1 ports 8 4 SATA Interface The chipset has two integrated SATA host controllers that support independent DMA operation on up to six port 6 x 3Gb s SATA The SATA controller contains two modes of operation a legacy mode using I O space and an AHCI mode using memory space Software that uses legacy mode will not have AHCI capabilities 8 5 AHCI The chipset provides hardware support for Advanced Host Controller Interface A
20. A No ia MSTCBL On board SATA Controller RAID SATA RAID 2 MSTROCBL Embedded SATA SW RAID PERC S100 RAID O MSTR1CBL Embedded SATA SW RAID PERC S100 RAID 1 SAS SATA 4 ASSROCBL Add in SAS SATA RAID card RAID O PERC S300 RAID with 2 hard drives PowerEdge R210 Il Technical Guide Dell pee EEE e ASSR10CBL Add in SAS SATA RAID card RAID 10 PERC S300 ASSCBL Add in SAS SATA RAID card No RAID PERC H200 ASSROCBL Add in SAS SATA RAID card RAID O PERC H200 ASSR1CBL Add in SAS SATA RAID card RAID 1 PERC H200 SAS SSD 12 ASSRIOCBL Add in SAS SSD RAID card RAID 10 RAID PERC H200 Note Configurations that require more than 3 hard drives will be available in Q2 2011 Additional restrictions for RAID configurations are listed as follows Hard drives must be all 3 5 or 2 5 2 5 drives available Q2 2011 Must be all SAS or all SATA or all SSD No Mixed Hard drives allowed SSD support requires PERC H200 PERC S300 does not support SSD The PERC S300 does not support the following virtualization solutions Microsoft Hyper V server 2008 x64 download version Microsoft Windows Server 2008 x64 Hyper V role enabled Microsoft Windows Server 2008 SP2 x64 Hyper V role enabled Microsoft Windows Server 2008 R2 Microsoft Windows 7 includes SP2 bits x64 Hyper V role enabled The PERC S300 does not support Linux operating systems or VMware virtualization software 12 4 Optical
21. A Se RR ARENA aia 38 Table 15 Factory RAID Configurations 2 acr dave e iato oa a a 38 Table6 Graphics Video MOdeS inen cin ntn tre hn ox hn enr kn i Rio P e IRR RN P RI 40 Table 17 Supported Racks ancora nsa oe eon O RO aretes 41 Table 18 Rail Adjustability Ranges and Depth oci eaa xdi ee xu EA Rer AAA 41 Table 19 Unified Server Configurator Features and Description eeeeeleeeeeeeeeeeees 46 Table 20 Features List for Base Management Functionality iDRAC6 and vFlash 48 Jadble 71 Volatility Table toss as Do ds ko a Mae 51 Table 22 Product Safety CertiTICatlOlis ciclos 54 Table 23 Electromagnetic Compatibility Certifications eceeeee eee enne 55 Table 24 Ergonomics Acoustics and YENES used co oer dor eid oat ood da REA aoa aes 55 Table 25 dnd stry Standard oirlo 56 V PowerEdge R210 II Technical Guide Dell Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 Figure 14 Figures Chassis DIMENSIONS a a aaa 13 Front View With Bezel ra 14 Front View Without BEZEL oia oie a iio a PERIELIO REEE EERDE 14 Back MT LEE 14 Power BULL 15 Internal Chassis VIEW acess eriein aneio rE EEEE in 16 Front Panel View with LED Control Panel 412 dee dee eaa open iia 17 LED Control Panel Detailed View iveco a in tn e i or earn 17 Formulas for Maximum Operating Temperature for Given A
22. Compatibility Module a 29 8 10 Advanced Programmable Interrupt Controller PIC ooooooooococnccccccnccoconananoos 29 811 USB INterface invada 29 8 17 Real Time Clock RT A aa 29 US BRISAS Maca en ada t sau O E us tkt EEEE 30 8 14 Enhanced Power Management circa deck ee iaa IR Ear LARES 30 8 15 System Management Features deer a A A RR ORE d 30 a A A AA A E E A eee eE 30 8 15 2 Processor Present Indicator tancia d RA REY LR RENE E LARSEN 30 9 15 3 Error Code Correction ECC Reporting ui A e utu Due aea aid 30 8 15 4 Function Disable eee SS eoe Sil eg Sie ele gis dg nas 30 8 15 53 1 Intruder Detectua ad Ire SITO UE I Se RR I SU send seeded shies aasesuietes 30 8 16 System Management Bus SMBus 2 0 4 2d es a Ra au PAR RE RM uad 31 8 17 Intel Virtualization Technology for Directed 1 0 Lecce eene eene 31 rU occ rtc HH M EHE 32 9 1 OVERVIEW v e SL tub ero ao dado es 32 9 2 Supported ACPI Stakes ii ASS 33 9 2 1 Power Management Modes 2s exero chord due xa key ec 33 10 Embedded NICs EAN on Motherboard EOM cc oce Rot e ce P tete n o a ice Veet eR 36 TOA OVerVIe Wisteria 36 10 2 A NO 36 A ES AAA A eter Nob Urso ite fob er ute E ee LUC Ee 37 TVA POVERVIOW P D a e EDE 37 VEZ Quantities and Priorities cse rere Dy nr EEG e EU NR EU M 37 TES POL Card DIMENSIONS eese C DIU a ROB RR Etc ica cte Rcs ace ea ale es EE Na Va EC sat 37
23. D LEER TA DR GEO dak 19 5 4 Environmental Specifications 046s way tEteryosbcen FE A E rara E PAS od VoR EE dA 20 5 5 ENERGY STAR COMPMANGCE a ai a 21 5 6 o A IIT D UN E TIT I 21 5 7 ACOUSTICS 2s datos tad E 21 6 Processors AA de er ee pon Ede e Eee res edi Me Aere es Eq E Aur ex QU SE RUC P ERR QURE 24 6 1 OVEIVIEW ssdevssic ste exo AAA ESA eel x ite a e n EC ees 24 6 2 Features TEE 24 6 3 S pported Process OS sensen ease A Cai aque e 24 6 4 Processor Cornfiguratioris susce re ee tea Rn ea Qut je Ron a ac o i n CN ROTE deti e d 25 6 5 Processor Installation 25 A DD EE 26 iii PowerEdge R210 II Technical Guide 7 1 OVERVIGW II A IAS A AAA eim uda 26 7 2 DIMMS SUG ELS ced e a d o aee en Ma en Marrs Mn eene aa up aea AS 26 7 3 DIMM MOS cid ci ex Ra eR EFI E AA ausude eda EFaxde d E NR PEE 26 Jud Speed A A su Rats D MEAE En A Ee a 26 7 5 SPAIN CS 27 7 6 MEO eO T o 27 HI ID O O O ee nh tte 27 7 8 Supported Configuration Sci A ra AAA 27 A A A a onu D 28 8 1 OVEIVIEW Sites eet set AN REA AAA ARIAS 28 8 2 Direct Media INGON ACC cinta ux ee ALA nta Ro n nd ded AA e AAA AA 28 8 3 PEDEXPTESS Intel 3 Qro aue d Oe an va EEEE O cheese Sx EN EROR Pea Un ie S aS 28 8 4 SAT ACINVERTACe os EE tue it IS AS 28 8 55 Ai toro rr cosas 28 8 6 PCIA A A A as 28 8 7 Low Pin Count LPC Interfaces o ree etiaro vieta e t et e ttt teu 28 8 8 senal Peripheral Interface SAludos o loas 28 8 9
24. E SIAE Dus OF DMI II Direct Media Interface HyperTransport Cache 8MB Chipset Intel C202 Memory Up to 32GB 4 DIMMs 1GB 2GB 4GB 8GB DDR3 up to 1333MHz 1 0 Slots 1 PCle x16 G2 slot Internal Controllers PERC H200 6Gb s PERC S100 software based PERC S300 software based External Controllers PERC H800 6Gb s available Q4 2011 External HBAs non RAID 6GB s SAS HBA RAID Controller Cabled options available Drive Bays Up to two 3 5 SAS or SATA Up to four 2 5 SSD or SAS Maximum Internal Storage Up to 4TB Cabled hard drive options Hard Drives 3 5 SAS 15K 10K nearline SAS 7 2K SATA 7 2K 5 4K 2 5 SSD or SAS 10K Broadcom NetXtreme 5709 Dual Port Gigabit Ethernet NIC Copper w TOE PCle x4 Broadcom NetXtreme 5709 Dual Port Gigabit Ethernet NIC Copper TOE iSCSI PCle x4 Broadcom NetXtreme Il 5709 Quad Port Gigabit Ethernet NIC Copper w TOE iSCSI PCle x4 Intel Gigabit ET Dual Port Adapter Gigabit Ethernet NIC PCle x4 Intel Gigabit ET Quad Port Adapter Gigabit Ethernet NIC PCle x4 Communications 11 PowerEdge R210 II Technical Guide Dell Power Supply Single cabled power supply 250W Availability Quad pack LED diagnostics ECC memory add in RAID TPM TCM Video Matrox G200eW with 8MB memory Remote Management iDRAC6 optional Systems Management Dell OpenManage BMC IPMI 2 0 compliant Unif
25. HCI a new programming interface for SATA host controllers Platforms supporting AHCI may take advantage of performance features such as no master slave designation for SATA devices each device is treated as a master and hardware assisted native command queuing AHCI also provides usability enhancements such as Hot Plug AHCI requires appropriate software support for example an AHCI driver and for some features hardware support in the SATA device or additional platform hardware 8 6 PCI Interface The C200 Series chipset PCI interface provides a 33 MHz Revision 2 3 implementation The chipset integrates a PCI arbiter that supports up to four external PCI bus masters in addition to the internal requests This allows for combinations of up to 8 PCI down devices and PCI slots 8 7 Low Pin Count LPC Interface The LPC bridge function of the PCH resides in PCI Device 31 Function 0 In addition to the LPC bridge function D31 FO contains other functional units including DMA Interrupt controllers Timers Power Management System Management GPIO and RTC 8 8 Serial Peripheral Interface SPI The chipset implements an SPI Interface as an alternative interface for the BIOS flash device An SPI flash device can be used as a replacement for the FWH and is required to support Gigabit Ethernet 28 PowerEdge R210 II Technical Guide Dell Intel Active Management Technology and integrated Intel Quiet System Technology The chipset supports
26. PA A E O O OR SR RO 38 12 1 A CN 38 12 2 H rd DRIVES inc ous et achten dtt eh Sa dat ER e tup e ch ORA 38 12 3 RAID Config ulations seg nurus eiae aa Y EV ise Fer a VEN ded re ape ua CY a Vida E Fe EAR ERAT CE TE REESE RE 38 12 4 Optical D IVeS v prete E RE ER ER A EIN KE EARN S ERR LA MENU ER NM ERR a ES 39 TAO Tape Dres E cir te ta od Ord 39 13 WI ri ds a A AAA A EFE Ed E ERN BRE 40 14 Rack a AA A A A ON 41 14 41 OVerVIe sensen ensen e N AE As 41 iv PowerEdge R210 II Technical Guide Dell CE A O O O Rd a o td 41 14 3 Cable Management Arm CMA AAA AA A 42 14 4 RACK VIBWs scole ye ta any A AR A E cl eM e ERAN de eSa 42 15 Operating Systemsa aana AS AE SA a a e e tate quete nee 44 16 Systems Managemient oues eene As 45 EE Oa ale ba onde eae O 45 16 2 Server Managements A A IE depu eee eines 45 16 3 Embedded Server Management scccscssscccccccenesssssccceeesessssseseseesessseeesoeees 46 16 4 Dell Lifecycle Controller and Unified Server Configurator ooooocoooccccccccocccccncccooo 46 16 5 Integrated Dell Remote Access Controller ooooooooccconococcnocccorccoccnononocononono 47 16 6 JDRACO EXDEGSS eco ei erede nomi rra c AE AAA AA AE AAA AREA AA AAA ARA n t A A 47 16 7 A O 47 16 8 iDRAC6 Enterprise with Virtual Flash vflash Media ooooooooococcccnococcncccnocononono 47 17 Peripherals evito trar dni cis 50 Appendix A statement af Volatility merie A dneatn EA KORRE OER 51 Ap
27. PM during normal operation Access to the NV Storage is controlled by the TPM owner Purpose e g boot code Trusted Platform Module NV storage May be used to securely storage of encryption keys How is data input to this memory TCG TPM Specification defined command interface or Using TPM Enabled operating systems How is this memory write protected As defined by the TCG TPM Specification protection of this NV memory area is configurable by the TPM owner Remarks Server BMC Baseboard Management Details Controller Firmware Flash Memory Size 16MB Flash Type e g Flash PROM EEPROM SPI Flash Can user programs or operating system write No data to it during normal operation Purpose e g boot code Stores the BMC Firmware How is data input to this memory Loading flash memory requires a vendor provided firmware file and loader program which is executed by booting up the system from a floppy or OS based executable containing the firmware file and the loader System loaded with arbitrary data in firmware memory would not operate How is this memory write protected Software write protected Remarks individual components Please direct any questions to your Dell Marketing contact PowerEdge R210 II Technical Guide 53 Dell Appendix B Certifications B 1 Regulatory Certifications Regulatory compliance certificates can be located at the
28. PowerEdge R210 11 ban Technical Guide The PowerEdge R210 Il offers performance energy efficiency and ease of management for businesses of all sizes Dell This document is for informational purposes only Dell reserves the right to make changes without further notice to any products herein The content provided is as is and without express or implied warranties of any kind Dell PowerEdge and ReadyRails are trademarks of Dell Inc Citrix is a registered trademark and XenServer is a trademark of Citrix Systems Inc and or one or more of its subsidiaries and may be registered in the United States Patent and Trademark Office and in other countries Intel Xeon Celeron and Pentium are registered trademarks and Core is a trademark of Intel Corporation in the U S and other countries Broadcom is a registered trademark and NetXtreme is a trademark of Broadcom Corporation and or its affiliates in the United States certain other countries and or the EU Matrox is a registered trademark of Matrox Electronic Systems Ltd Microsoft and SQL Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and or other countries Red Hat is a registered trademark of Red Hat Inc in the United States and other countries Linux is a registered trademark of Linus Torvalds Symantec is a trademark owned by Symantec Corporation or its affiliates in the U S and other countries VMware is a registered tra
29. Rails ReadyRails Static Rails for 4 post and 2 post racks support the following e Toolless installation in 19 EIA 310 E compliant square or unthreaded round hole 4 post racks including all generations of Dell racks e Tooled installation in 19 EIA 310 E compliant threaded hole 4 post and 2 post racks See section 14 for more details 4 10 Fans There are three system fans located in the R210 Il system PowerEdge R210 II Technical Guide Dell For information on removing and installing the system fans see the Installing System Components chapter of the PowerEdge R210 II Owner s Manual on Support Dell com for more information 4 11 LED Control Panel Figure 7 and Figure 8 show the LED control panel PowerEdge R415 o Figure 7 Front Panel View with LED Control Panel PowerEdge R210 Il 6 Figure 8 LED Control Panel Detailed View For a complete description of LED indicators their causes and possible courses of action to take to resolve an error see the Diagnostic Lights Optional section in the About Your System chapter in the PowerEdge R210 Il Owner s Manual on Support Dell com 4 12 Security 4 12 1 Cover Latch The PowerEdge R210 Il comes with a coin lock entry latch on the top cover of the unit and provides security for the entire system The lock provides for toolless access to the chassis 4 12 2 Bezel A metal bezel an available option and is mounted to the front of the chassis A lock on the bezel is us
30. a to it during normal operation Yes under software control Purpose e g boot code Contains LOM boot code and configuration data How is data input to this memory Requires vendor provided firmware file and loader program used during factory assembly or possible field update A system loaded with arbitrary data in firmware memory would not operate How is this memory write protected Software control Remarks Server System Event Log Memory FRU Details Size 4 KB Type e g Flash PROM EEPROM SEEPROM Can user programs or operating system write No data to it during normal operation Purpose e g boot code Store System Events How is data input to this memory BMC controller write How is this memory write protected Not write protected Remarks PowerEdge R210 Il Technical Guide 52 Dell To obtain optional component information please refer to the Dell Statement of Volatility for the TPM Trusted Platform Module For boards shipped outside of China Boards sold to destinations in China do not have TPM at this time Details Size Unspecified size of user ROM RAM EEPROM 128 bytes of OTP memory included Type e g Flash PROM EEPROM ROM RAM EEPROM Can user programs or operating system write data to it during normal operation Yes OS and applications that conform to the TCG standard can write data to the T
31. ad and restored This is required to save and restore system state after power has been removed and restored to the platform 8 10 Advanced Programmable Interrupt Controller APIC In addition to the standard ISA compatible Programmable Interrupt Controller PIC described in the previous section the Ibex Peak incorporates the Advanced Programmable Interrupt Controller APIC 8 11 USB Interface The C200 Series chipset contains up to two Enhanced Host Controller Interface EHCI host controllers that support USB high speed signaling High speed USB 2 0 allows data transfers up to 480 Mb s which is 40 times faster than full speed USB The chipset also contains up to seven Universal Host Controller Interface UHCI controllers that support USB full speed and low speed signaling The chipset supports up to fourteen USB 2 0 ports All fourteen ports are high speed full speed and low speed capable The port routing logic determines whether a USB port is controlled by one of the UHCI or EHCI controllers 8 12 Real Time Clock RTC The Real Time Clock RTC module provides a battery backed up date and time keeping device with two banks of static RAM with 128 bytes each although the first bank has 114 bytes for general purpose usage Three interrupt features are available time of day alarm with once a second to once a month range periodic rates of 122 us to 500 ms and end of update cycle notification Seconds minutes hours days day of week
32. by component separately The NV components detailed in Table 21 are present in the PowerEdge R210 II server Table 21 Volatility Table Server BIOS Memory Details Size 64 Mbit Type e g Flash PROM EEPROM Flash EEPROM Can user programs or operating system write No data to it during normal operation Purpose e g boot code Boot Code and Configuration Information How is data input to this memory Loading flash memory requires a vendor provided firmware file and loader program which is executed by booting up the system from a floppy or OS based executable containing the firmware file and the loader System loaded with arbitrary data in firmware memory would not operate How is this memory write protected Software write protected Remarks Server CMOS Complementary Metal Oxide Details Semiconductor Memory Size 512 Bytes Type e g Flash PROM EEPROM Battery backed NVRAM Can user programs or operating system write No data to it during normal operation Purpose e g boot code RTC amp Configuration settings How is data input to this memory F2 Setup Menu during POST How is this memory write protected N A PowerEdge R210 II Technical Guide 51 Dell LOM LAN Network Interface on Details Motherboard Memory Size 4Mb 512KB Type e g Flash PROM EEPROM Flash Can user programs or operating system write dat
33. demark and vSphere is a trademark of VMware Inc in the United States and or other jurisdictions Insyde is a registered trademark of Insyde Software Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products Dell disclaims proprietary interest in the marks and names of others OCopyright 2011 Dell Inc All rights reserved Reproduction or translation of any part of this work beyond that permitted by U S copyright laws without the written permission of Dell Inc is unlawful and strictly forbidden June 2011 PowerEdge R210 II Technical Guide Dell Table of Contents 1 Product Cormparisotus sl oso E Ue A OA AO 7 1 1 AO A A siete muse eiue inna na inea 7 1 2 Key Bene bits ages eere rete Eee atc eee Site ars ola tet urea ses 7 1 3 Flexible Secure TEChnOlOSy a E EA AAA AAA 7 1 4 Easy to Manage xv A A A A AN DAA de RS 8 1 5 COMPAS is 8 2 New Technologies EA E AA EA E Qd Ras 10 3 System OVERVIEW 2 A AS A AAA A ASA een Wek ql RR 13 4 1 Chassis Description 4g choccdvesnodacan aute d exa do ite Re px Mee td etes dq EN MEER REI 13 4 2 DIMENSIONS and Weights vtl o oet teeth eeu aedis De tico e bate bate aeo ua 13 4 3 Front Panel View and Features oooccccccccccccccccccccccccccccc ee hehehe 14 4 4 Back Paneb View and Features da e be E ated epe dies 14 4 5 Power Button LED coena Re xen ex exe ca eU E Pide UR ER PC ESSERE E CR RES 14 4 6 System ta
34. documentation located at http go microsoft com fwlink Linkld 143551 12 PowerEdge R210 II Technical Guide Dell 4 Mechanical 4 1 Chassis Description The PowerEdge R210 Il is a 1U rack mount design that supports the following features Two cabled 3 5 drive bays for SATA or SAS hard drives or four 2 5 drive bays for SAS or SSD drives available Q2 2011 Dual Gigabit LAN on motherboard LOM Four DIMM slots TPM security feature One riser card for optional PCle expansion card Optional iDRAC6 Enterprise and iDRAC6 Express card mounted on planar without PCI slot occupied Support for 11G slim static and slim sliding rails Single non redundant power supply Diagnostic LED panel 4 2 Dimensions and Weight Figure 1 details the dimensions and weight for the PowerEdge R210 Il Za Ze TOP VIEW Bezel or Outer Most Feature je ER ElA Rack Flange Y SIDE VIEW i Za 2 Xb Y With Zb Zc Max Weight Bezel 482 6mm 434mm 42 4mm 35mm 3907mm 3943mm 8 09 ks l i i i 17 76 lbs Zb measures to the nominal rear wall external surface where the motherboard I O connectors reside Figure 1 Chassis Dimensions 13 PowerEdge R210 II Technical Guide Dell 4 3 Front Panel View and Features Figure 2 and Figure 3 show the front views of the PowerEdge R210 II Figure 2 Front View With Bezel Figure 3 Front View Without Bezel See the Front Panel Fea
35. earch JESD79 3A pdf LPC Low Pin Count Interface Specification Rev 1 1 http developer AMD com design chipsets industry lpc ht m PCI Express PCI Express Base Specification Rev 2 0 http www pcisig com specifications pciexpress PMBus Power System Management Protocol Specification v1 1 http pmbus info specs html SAS http www t10 org cgi bin ac pUt f amp f sas1r10 pdf Serial Attached SCSI v1 1 SATA http sata io org Serial ATA Rev 2 6 SATA Il Extensions to SATA 1 0a Rev 1 2 SMBIOS System Management BIOS Reference Specification v2 6 http www dmtf org standards smbios TPM Trusted Platform Module Specification v1 2 PowerEdge R210 Il Technical Guide http www trustedcomputinggroup org resources tpm mai n specification 56 Dell Standard URL for Information and Specifications UEFI Unified Extensible Firmware Interface Specification v2 1 http www uefi org specs USB Universal Serial Bus Specification Rev 2 0 http www usb org developers docs Windows Logo Windows Logo Program System and Device Requirements v3 10 http www microsoft com whdc winlogo hwrequirements mspx PowerEdge R210 Il Technical Guide 57
36. ed to protect un authorized access to system peripherals and the power button System status on the LED control panel is viewable even when the bezel is installed 4 12 3 Hard Drive Cabled hard drives are only accessible by opening the top cover thus locking the top cover secures the hard drives For information about installing or removing the hard drives see the Hard Drives section in the Installing System Components chapter in the PowerEdge R210 II Owner s Manual on Support Dell com 4 12 4 Trusted Platform Module TPM The PowerEdge R210 Il uses a TPM encryption chip solution on the system board with BIOS support worldwide except for China where Trusted Computing Module TCM is the standard TPM is disabled by default 17 PowerEdge R210 Il Technical Guide Dell The TPM is used to generate and store keys protect and authenticate passwords and create and store digital certificates The TPM can also be used to store Microsoft BitLocker keys for hard drive encryption features in Microsoft Windows Server 2008 TPM is enabled through a BIOS option and uses HMAC SHA1 160 for binding 4 12 5 Power Switch Security The control panel is designed so the power switch cannot be accidentally activated The lock on the bezel secures the switch behind the bezel In addition there is a setting in the CMOS setup that disables the power button function 4 12 6 Intrusion Alert A chassis intrusion switch mounted inside the system chassis
37. ed to report errors diagnose the system and recover from system lockups without the aid of an external microcontroller 8 15 1 TCO Timer The chipset s integrated programmable TCO timer is used to detect system locks The first expiration of the timer generates an SMIZ that the system can use to recover from a software lock The second expiration of the timer causes a system reset to recover from a hardware lock 8 15 2 Processor Present Indicator The chipset looks for the processor to fetch the first instruction after reset If the processor does not fetch the first instruction the Ibex Peak will reboot the system 8 15 3 Error Code Correction ECC Reporting When detecting an ECC error the host controller has the ability to send one of several messages to the chipset The host controller can instruct the chipset to generate an SMIZ NMI SERRZ or TCO interrupt 8 15 4 Function Disable The chipset provides the ability to disable the following integrated functions LAN USB LPC Intel HD Audio SATA PCI Express or SMBus Once disabled these functions no longer decode I O memory or PCI configuration space Also no interrupts or power management events are generated from the disabled functions 8 15 5 Intruder Detect The chipset provides an input signal INTRUDERZ that can be attached to a switch that is activated when the system case is opened The chipset can be programmed to generate an SMIZ or TCO interrupt due to an active
38. er mount only 41 PowerEdge R210 II Technical Guide Dell The min max values listed in Table 18 represent the allowable distance between the front and rear mounting flanges in the rack Rail depth represents the minimum depth of the rail as measured from the rack front mounting flanges when the rail rear bracket is positioned all the way forward 14 3 Cable Management Arm CMA The static rails for the R210 II support a wide variety of racks and mounting configurations but do not support the ability to extend the system out of the rack for service Thus they do not provide support for a cable management arm CMA 14 4 Rack View The A4 and A6 rail systems are stab in designs meaning that the inner chassis rail members must first be attached to the sides of the system and then inserted into the outer cabinet members installed in the rack TE Figure 11 A4 Static Rail System Figure 12 A6 Static Rail System 42 PowerEdge R210 Il Technical Guide Dell Figure 13 shows a view of the R210 II mounted in the A4 A6 rail systems in the 2 post center mount configuration The rear brackets on the A6 rail system can be removed and discarded providing a much smaller mounting footprint than the A4 rail system A6 back brackets can be removed and discarded R210 Il A6 Rail System A4 Rail System Figure 13 A4 and A6 Rail Systems in 2 post Center Mount Configuration Figure 14 shows the R210 Il mounted in the A4
39. flash e RIB Support 32 PowerEdge R210 II Technical Guide Dell 9 2 Supported ACPI States e ACPI compliance SO S4 S5 supported e No S1 S2 S3 STR support e S4 supported by OS only Table 11 Supported ACPI States so SA S5 Events Wake Up SON S1 52 53 Hibernate OS Soft y supported Off Power Button Y Y Y RTC alarm v WOL v iDRAC A s Y 3 9 2 1 Power Management Modes The R210 Il uses operating system based power management 9 2 1 1 Power Saving BIOS Setting OS Control Intel processors support Demand Based Switching DBS which enables the processor to dynamically change its operating frequency in response to workload changes The industry standard implementation of this power management feature is in the Operating System OS The OS monitors process and thread level utilization of the processor and uses processor controls to change the processor s operating frequency For heavy workloads the OS runs the processor at higher frequencies for additional performance Lighter workloads do not need high performance thus the OS runs the processor at lower frequencies 9 2 1 2 Maximum Performance The Maximum Performance Mode disables power management In this mode the processor frequency is statically set to the highest supported frequency The power management features are implemented through two categories fixed or generic Fixed featu
40. following sites e http ausreactorprd01 reactor xCertSearch asp e http www dell com content topics global aspx about dell values regulatory compliance dec conform c us amp l en amp s corp B 2 Product Safety Certifications The product has been certified and bears the Mark as applicable of the Product Safety authorities as indicated in Table 22 Table 22 Product Safety Certifications Country Region Authority or Mark Argentina IRAM Belarus BELLIS Canada SCC China CNCA or CCC Croatia KONCAR European Union CE Germany TUV IECEE IECEE CB Israel SII Kazakhstan OTAN CKT Kenya KEBS Kuwait KUCAS Mexico NYCE or NOM Moldova INSM Nigeria SONCAP Norway NEMKO Russia GOST Saudi Arabia KSA ICCP South Africa NRCS Taiwan BSMI UKRTEST or Ukraine UKRSERTCOMPUTER United States NRTL Uzbekistan STZ PowerEdge R210 Il Technical Guide 54 Dell B3 Electromagnetic Compatibility The product has been certified and bears the Mark as applicable of the EMC authorities as indicated in Table 23 Table 23 Electromagnetic Compatibility Certifications Country Region Authority or Mark Class Australia New ACMA or C Tick Zealand Class A Belarus BELLIS Class A Bosnia amp Herzegovina KVALITET Montenegro Serbia Class A Canada ICES Class A China CNCA or CCC Class A Croatia KONCAR Cla
41. hz 1067Mhz 800Mhz Minimum Power Fan Algorithm Maximum Performance Minimum Power PowerEdge R210 Il Technical Guide Dell 10 Embedded NICs LAN on Motherboard LOM 10 1 Overview The PowerEdge R210 Il includes a Broadcom 5716C chip embedded on the motherboard The 5716 chip is connected to the IOH via a PCI Express x4 gen2 link The 5716 chip provides two 1x Gigabit Ethernet ports with two RJ 45 connectors on the rear of the system Other details include e The firmware for the LOM chip resides in a flash part The R210 Il supports Wake On LAN WOL from either port 10 2 Features The Broadcom 5716C controller based LOM supports multiple functions over a unified fabric to help manage Ethernet iSCSI and remote management traffic on each port simultaneously The LOM provides dual 10 100 1000 Gigabit Ethernet functions an IEEE 802 3 compliant media access controller MAC and a UTP copper physical layer transceiver solution for high performance network applications The LOM also supports the following functions e Multiple speed support with dual 10 100 1000 Mbps Ethernet MACs including half duplex and full duplex capability and a dual 10 100 1000 copper PHY e PCle compliance with an x4 PCI Express v2 0 and v1 1 compliant bus interface e Diagnostics o Link quality indicator LED o Link speed indicator LED o Broadcom remote cable management and diagnostics software Broadcom Advanced Control Suite BACS o LOM continually m
42. ied Server Configurator Lifecycle Controller enabled through optional iDRAC6 Express iDRAC6 Enterprise and vFlash Rack Support ReadyRails static rails for toolless mounting in 4 post racks with square or unthreaded round holes or tooled mounting in 4 post threaded and 2 post Telco racks Operating Systems Microsoft Windows Small Business Server 2011 Microsoft Windows Server 2008 R2 Foundation SP1 includes Hyper V v2 Microsoft Windows Server 2008 SP2 x86 x64 x64 includes Hyper V Microsoft Windows Server 2008 R2 SP1 x64 includes Hyper V v2 Novell SUSE Linux Enterprise Server Red Hat Enterprise Linux For more information on the specific versions and additions visit www dell com OSsupport Featured Database Application Microsoft SQL Server solutions see Dell com SQL GB means 1 billion bytes and TB equals 1 trillion bytes actual capacity varies with preloaded material and operating environment and will be less Maximum of four hard drives available Q2 2011 Windows Server 2008 R2 Foundation allows only 15 user accounts and requires certain Active Directory AD configurations If not configured according to the product documentation the software will generate warnings to correct the configuration After a certain amount of time the software will only run for one hour at a time until the configuration is corrected For more information about these features review the product
43. igure 10 Formulas for Maximum Operating Temperature for Given Altitude F 20 PowerEdge R210 II Technical Guide Dell Table 5 shows the shock and vibration specifications for the R210 II Table 5 Shock and Vibration Specifications Maximum Vibration Operating 0 26Grms at 5 350Hz for 15 minutes Storage 1 88Grms at 10 500Hz for 15 minutes Maximum Shock One shock pulse in the positive z axis one pulse Operating on each side of the system of 31G for 2 6ms in the operational orientation Storage Six consecutively executed shock pulses in the Six consecutively executed shock pulses in the positive and negative x y and z axes one pulse on each side of the system of 71G for up to 2ms positive and negative x y and z axes one pulse on each side of the system of Half sine shock 71G for up to 2ms and square wave shock 326 270 in sec 5 5 ENERGY STAR Compliance ENERGY STAR qualified configurations can be accessed from the ENERGY STAR Compliance results landing page on Dell com 5 6 Thermal The thermal design of the PowerEdge R210 II reflects the following Closed loop thermal control algorithm A closed loop thermal control method uses feedback temperatures to dynamically determine proper fan speeds Comprehensive thermal management The PowerEdge R210 II controls system cooling fan speed based on several different responses from critical component sensors such as processor temperature
44. isk drive bay Power is soft switched allowing power cycling using a switch on the front of the system enclosure or through software control server management functions The power system is compatible with industry standards such as ACPI and Server 2000 The power supply is equipped with automatic input voltage detection 5 2 Power Supply Specifications Table 3 Power Supply Specifications Feature Non redundant Power Supply L 210 mm x W 106 mm x H 40 Dimensions mm Status Indicators None Integrated Fans One AC Cord Rating 15 Amps 120 VAC 10 Amps 240 VAC Input Voltage 90 264 VAC Auto ranging Yes Line Frequency 47 63 Hertz Maximum Inrush Current Under typical line conditions and over the entire system ambient operating range the inrush current may reach 55 Amps for 10 ms or less Hot plug Capability No Output Power 250W Maximum Heat Dissipation 1039 BTU per hour maximum Efficiency 20 to 100 Load 82 to 85 115 VAC 82 to 85 230 VAC 5 3 Heat Dissipation The heat dissipation for the R210 II power supply is measured at 1040 BTU hr maximum PowerEdge R210 II Technical Guide 19 Dell 5 4 Environmental Specifications The airborne contaminant level is class G2 or lower as defined by ISA S71 04 1985 Table 4 lists the environmental specifications for the R210 II Table 4 Environmental Specifications
45. l PowerEdge R210 Il Owner s Manual on Support dell com 11 3 PCI Card Dimensions Refer to the Expansion Cards and Expansion Card Risers section in the Installing System Components chapter of the Dell PowerEdge R210 Il Owner s Manual on Support dell com 97 PowerEdge R210 II Technical Guide Dell 12 Storage 12 1 Overview The PowerEdge R210 Il supports the following hard drive configurations e 2x3 5 cabled SATA drives using the motherboard SATA connector e 2x3 5 cabled SAS nearline SAS or SATA drives using an add on storage controller e 4x2 5 SSD or SAS drives using an add on storage controller available Q2 2011 The hard drive configuration must be selected at point of purchase and is not an upgrade option 12 2 Hard Drives Table 14 lists the supported hard drives for the PowerEdge R210 II For the latest information on supported hard drives visit Dell com Table 14 Supported Hard Drives Form Factor Capacity Speed Type 3 57 250GB 500GB 1TB 2TB 7 2K SATA 3 5 500GB 1TB 2TB 7 2K NL SAS 3 5 146GB 300GB 450GB 600GB 15K SAS 257 100GB 200GB N A SATA SSD 257 146GB 300GB 600GB 900GB 10K SAS 12 5 drives available Q2 2011 12 3 RAID Configurations Table 15 details the factory RAID configurations for the PowerEdge R210 Il Table 15 Factory RAID Configurations Non Mixed Drives all SATA all SSD or all SAS Config Configurations Description Type Name SAT
46. ltitude C 20 Formulas for Maximum Operating Temperature for Given Altitude F 20 A4 Static Rall Systerti iiie nie ori n nn rr or Fa Via on att P Rape eoe t e D NIE CR S 42 A6 Static Rall SySEGID ue YE 42 A4 and A6 Rail Systems in 2 post Center Mount Configuration Leeeueueeees 43 A4 and A6 Rail Systems in 2 post Flush Mount Configuration Leeeeeeeeeee 43 vi PowerEdge R210 II Technical Guide Dell 1 Product Comparison 1 1 Overview The PowerEdge R210 II is an entry level yet enterprise ready ultra dense 1 socket 1U rack server that is well suited for a broad range of workloads from small businesses applications to high density scale out compute farms It offers the performance and features to run your business applications that facilitate data coordination and sharing data protection management and scalability to support business growth With a full selection of processors to meet your performance needs the R210 II supports the Intel Xeon processor E3 1200 product family the Intel Core i3 2100 product family and Intel Pentium processors Also included are four DIMM slots with enough memory to handle common applications hard drive options for two 3 5 or four 2 5 available Q2 2011 cabled hard drives for flexible internal local storage one PCle true x16 slot to connect a variety of peripherals as well as the full Dell OpenManage suite
47. month and year are counted Daylight savings compensation is no longer supported The hour is represented in twelve or twenty four hour format and data can be represented in BCD or binary format The design is functionally compatible with the Motorola MS146818B The time keeping comes from a 32 768 kHz oscillating source which is divided to achieve an update every second The lower 14 bytes on the lower RAM block has very specific 29 PowerEdge R210 II Technical Guide Dell functions The first ten are for time and date information The next four OAh to ODh are registers which configure and report RTC functions 8 13 GPIO Various general purpose inputs and outputs are provided for custom system design The number of inputs and outputs varies depending on C200 series configuration 8 14 Enhanced Power Management The C200 series power management functions include enhanced clock control and various low power suspend states for example Suspend to RAM and Suspend to Disk A hardware based thermal management circuit permits software independent entrance to low power states The chipset contains full support for the Advanced Configuration and Power Interface ACPI Specification Revision 3 0a 8 15 System Management Features In addition to Intel AMT the C200 series chipset integrates several functions designed to manage the system and lower the total cost of ownership TCO of the system These system management functions are design
48. onitors various channel conditions e Power management options e Teaming using Broadcom software o Support for virtual LANs VLANs Split your physical LAN into logical parts Create logical segmentation of workgroups Enforce security policies for each logical segment o Group multiple network adapters together into teams providing network load balancing and fault tolerance functionality Support for Pre boot Execution Environment PXE iSCSI boot and Bootstrap Protocol BootP Support for Network Controller Sideband Interface NC SI IPv4 and IPv6 checksum offload IPv4 and IPv6 large send offload Jumbo MTU LSO and jumbo frames WOL capabilities Virtualization functionality Use of multiple queues 36 PowerEdge R210 II Technical Guide Dell 11 PCI Slots 11 1 Overview The PowerEdge R210 II planar provides one riser card which provides one x16 Gen2 PCI Express expansion slot e Slot supports full height half length cards connected to the IOH e Support for 25W maximum power e System does not support hot plugging or hot removal of PCle cards For more information on installing expansion cards and expansion card priority see the Expansion Cards and Expansion Card Risers section in the Installing System Components chapter of the Dell PowerEdge R210 Il Owner s Manual on Support dell com 11 2 Quantities and Priorities Refer to the Expansion Cards and Expansion Card Risers section in the Installing System Components chapter of the Del
49. ower wattage power supplies and features a built in user interface for ease of deployment With the PowerEdge R210 II you can e Protect data with hardware and software enabled encryption e Secure business information with a RAID configuration to make copies of data automatically e Provide email collaboration remote access automatic backup and data restore functionality with Windows SBS 2011 e Deploy your server faster and achieve productivity sooner with optional embedded management PowerEdge R210 II Technical Guide Dell 1 4 Easy to Manage The Dell PowerEdge R210 II lets you focus on running your business rather than running your servers Dell OpenManage systems management software helps to automate common management tasks thereby enhancing efficiency improving productivity and reducing the potential for error which can cause downtime The optional Dell Lifecycle Controller can simplify administrator tasks by performing a complete set of functions such as system deployment system updates hardware configuration and diagnostics from a single intuitive interface called Unified Server Configurator in a pre OS environment This eliminates the need to use and maintain multiple pieces of disparate CD DVD media With Dell Lifecycle Controller server deployment automation the R210 II is up and running fast 1 5 Comparison Table 1 Comparison of PowerEdge R210 II to R210 and R310 Feature R210 R210 Il R310 Processor Intel
50. pendix b Certifications LES ES rA tu SAS ES EN 54 Bi Regulatory Certifications sico oral ico 54 B2 Product Safety CertifICatlol it ia 54 b 3 Electromagnetic COMPADRE NR Mate 55 B4 Ergonomics Acoustics and Hygienics oooocccccccccccccccccccccccccoco coco r cnc hehehe 55 Appendix Es Industry Standards iussi o E Ora aeu ER nuE Cere EO ah E ee REESE EGO RE Eva e anus 56 Tables Table 1 Comparison of PowerEdge R210 II to R210 and R310 ooooooocococcncccnoncconacananoos 8 Table 2 Product Feature SUmilTial Yuri os 11 Table 3 Power Supply SpeciTICatlOrnsu usas oon y dt Rx xa d ep ER EQ ER CO REA RR ERR ERO RR ea da 19 Table 4 Environmental SPC CACIONES 20 Table 5 Shock and Vibration Specification RA 21 Table 6 AcousticaU5pecifiCatioris oe eet rn xr p ERA Ex P EBEXERNNES RAT TA NERKEE AN ER ER RII NEAN EUR 22 Table 7 Supported Intel Xeon Pr COSES q Ad 24 Table 8 Supported Intel Desktop Processors vita aa 25 Table 9 DIMMS SUD DORE COS Sante ies Macao oa La rna tana ca D tte 26 Table 10 Supported Configuration enirere reniet es a TE xa Revue MANDA a Mir Ea aeu US 27 Table 1 Supported ACPI States iri sede dece A Fa y euge RET REEUde ay ERES TE ATE d E ax Rede 33 Table 12 Power Management Peatll es cian ases leote ean rane ex euo EA x Wa RR e a DR Rd 34 Table 13 Power Prone vues rm n nnnc i ta or lea Fe Roh a race CR n ED AA A 35 Table 14 Supported Hard DTIVOS uos sae soot ie e oko no pete nae o d Xe L
51. r Dell com Faster System Updates Integration with Dell support automatically directed to latest versions of the Unified Server Configurator iDRAC RAID BIOS NIC and Power Supply Update Rollback Ability to recover to previous known good state for all updatable components More Comprehensive Diagnostics Diagnostic utilities are embedded on system Simplified Hardware Configuration Detects RAID controller and allows user to configure virtual disk and choose virtual disk as boot device eliminating the need to launch a separate utility Also provides configuration for DRAC BIOS and NIC LOM 46 PowerEdge R210 II Technical Guide Dell 16 5 Integrated Dell Remote Access Controller The integrated Dell Remote Access Controller iDRAC6 provides IT Administrators comprehensive yet straightforward management of remote servers by delivering as if you are there presence and control iDRAC6 helps users to save time and money by eliminating travel to the remote server s whether that server is located in a different room a different building a different city or in a different country iDRAC6 is a purchasable option and is available as three offerings iDRAC6 Express iDRAC6 Enterprise and Virtual Flash vFlash media e iDRAC6 Express is most appropriate for small to medium business customers with limited remote management needs e iDRAC6 Enterprise is appropriate for large data center customers with di
52. res use bits defined in the ACPI specification for specific capabilities The fixed feature bits give the OS complete control over the power management of a device since the location of the bits is given to the OS in the FACP table Thus a driver can directly access bits to control a device s power management Generic features have defined enable and status bits but the functionality is not fully visible to the OS Dell provides ASL code to handle the details of generic features allowing the OS to intelligently communicate with system specific hardware Table 12 summarizes the power management features on this system 33 PowerEdge R210 II Technical Guide Table 12 Power Management Features Feature Type Enable Status Description Ctrl bit location ACPI mode Fixed PCH The OS uses the SCI_EN bit to switch from legacy mode to switch ACPI mode Sleep states Fixed PCH Supported states SO Working S4 OS Hibernation in W2K and S5 Soft off S1 also called standby or suspend and S3 are not supported Power Button Fixed PCH In ACPI mode OS has control of the power button In non ACPI mode SMI handler owns power button events Real Time Fixed PCH The OS is able to configure the system to wake on the RTC Clock alarm Power Mgmt Fixed PCH 24 bit power management timer is used Timer Power Mgmt Generic PCH Each host bus s PMEZ signal is routed to a separate general Even
53. splay The optional upgrade to iDRAC6 provides features for managing the server remotely or in data center lights out environments Advanced iDRAC features require the installation of the optional iDRAC6 Enterprise card 16 4 Dell Lifecycle Controller and Unified Server Configurator Embedded management is comprised of several interdependent pieces Dell Lifecycle Controller Unified Server Configurator e iDRAC6 Dell Lifecycle Controller powers the embedded management features It includes integrated and tamper proof storage for system management tools and enablement utilities firmware drivers etc For servers with iDRAC6 Express the Lifecycle Controller offers pre OS server deployment OS installation platform updates platform configuration and diagnostics capabilities For servers without iDRAC6 Express this utility has limited functionality and offers OS installation and diagnostics capabilities only Dell Unified Server Configurator USC is a graphical user interface GUI that aids in local server provisioning in a pre OS environment To access the Unified Server Configurator press the F10 key within 10 seconds of the Dell logo appearance during the system boot process Table 19 details current functionality enabled by the USC Table 19 Unified Server Configurator Features and Description Feature Description Faster O S Installation Drivers and the installation utility are embedded on system so no need to scou
54. ss A European Union CE Class A Israel SII Class A Japan VCCI Class A Kazakhstan OTAN CKT Class A Moldova INSM Class A Norway NEMKO Class A Russia GOST Class A South Africa SABS Class A South Korea KCC Class A Taiwan BSMI Class A Ukraine UKRTEST or UKRSERTCOMPUTER Class A United States FCC Class A Uzbekistan STZ Class A Vietnam ICT Class A B 4 Ergonomics Acoustics and Hygienics The product has been certified and bears the Mark as applicable of the Ergonomics Acoustics and Hygienics authorities as indicated in Table 24 PowerEdge R210 Il Technical Guide Table 24 Ergonomics Acoustics and Hygienics Country Region Authority or Mark Belarus BELLIS Germany GS Russia GOST 55 Dell Appendix C Industry Standards The PowerEdge R210 Il system conforms to the industry standards detailed in Table 25 Table 25 Industry Standards Standard URL for Information and Specifications ACPI http www acpi info Advance Configuration and Power Interface Specification v2 0c Energy Star EPA Version 1 0 of the Computer Server specification http www energystar gov index cfm c archives enterprise servers Ethernet http standards ieee org getieee802 802 3 html IEEE 802 3 2005 IPMI http www intel com design servers ipmi Intelligent Platform Management Interface v2 0 DDR3 Memory DDR3 SDRAM Specification Rev 3A http www jedec org download s
55. stributed servers e iDRAC6 with vFlash Media is provided for large enterprise customers with requirements for system management automation 16 6 iDRAC6 Express The optional iDRAC6 Express is the first tier of iDRAC6 upgrades In addition to upgrading the system with a Lifecycle Controller the iDRAC6 Express offers the following key features Graphical web interface e Standard based interfaces Server Sensor monitoring and fault alerting Secure operation of remote access functions including authentication authorization and encryption e Power control and management with the ability to limit server power consumption and remotely control server power states e Advanced troubleshooting capabilities For more information on iDRAC6 Express features see Table 20 16 7 iDRAC6 Enterprise The optional iDRAC6 Enterprise card provides access to advanced iDRAC6 features The iDRAC6 Enterprise connects directly to the R210 Il planar and is mounted parallel to the planar with stand offs Key features for the iDRAC6 Enterprise include Scripting capability with Dell s Racadm command line Remote video keyboard and mouse control with Virtual Console e Remote media access with Virtual Media e Dedicated network interface 16 8 iDRAC6 Enterprise with Virtual Flash vFlash Media The iDRAC6 Enterprise can be upgraded by adding the vFlash Media card This is an 8 GB Dell branded SD card that enables a persistent 256 MB virtual flash
56. supports 4 DIMMs Memory configuration with one processor includes a 1 GB minimum and a 32 GB maximum 6 5 Processor Installation Refer to the Processors section in the Installing System Components chapter of the Dell PowerEdge R210 II Systems Owner s Manual on Support dell com for processor installation and removal instructions PowerEdge R210 II Technical Guide 25 Dell 7 Memory 7 1 Overview The R210 Il supports DDR3 memory providing a high performance high speed memory interface capable of low latency response and high throughput For the Intel processor based R210 Il up to 4 total DIMMs are supported Additional specifics regarding memory include e 2 Gb DRAM technology e 2channels per processor e Unbuffered UDIMM ECC DDR3 DIMMs e DDR3 speeds of 1066 1333 UDIMM only Single and dual rank UDIMMs all channels in a system run at the fastest common frequency Support for up to 32 GB UDIMM memory 4 x 8 GB UDIMMs Single DIMM configuration only with DIMM in socket A1 No support for quad rank DIMMs No RDIMM support Low voltage LV DIMM supported 3 5V only Non ECC DIMMs not supported 7 2 DIMMs Supported The R210 Il supports a minimum of 1 GB upgradeable to 32 GB of RAM using the following DIMM sizes Table 9 DIMMs Supported Unbuffered DRAM Technology DDR3 1333 1GB DIMM Single Rank 2Gb DDR3 1333 2GB DIMM Single Rank 2Gb DDR3 1333 4GB DIMM Dual Rank 2Gb DDR3 1333 8GB DIMM Dual Rank 4Gb
57. t PME purpose event pin in the chipset When a device signals PMEZ the system wakes if necessary the OS detects the event and a Dell defined ASL routine handles the event Wake on LAN is one example of a PME USB wake Generic N A This feature is not supported on this system since the S1 state is not supported DBS N A Processor MSRs This feature does P state transition under Windows C State N A Processor and This feature allows multiple C state supports for Processor Support PCH registers This feature will work under Windows and ACPI OS that understand C states Power Profile N A Processor IMC In addition to P C and T states BIOS will expose the Power support and PCH chipset registers Profiles to the OS Each Power profile will have a specific settings and it will fine tune processor MCH IOH and South Bridge PowerEdge R210 II Technical Guide 34 Dell Table 13 shows the power profile options for the R210 Il Table 13 Power Profiles Maximum Performance DBPM Disabled BIOS sets P State to max Memory frequency Maximum Performance Fan algorithm Maximum Performance OS Control Enable OS DBPM Control BIOS exposes all possible P states to OS Memory frequency Maximum Performance Fan algorithm Minimum Power Custom CPU Power and Performance Management Maximum Performance Minimum Power OS DBPM System DBPM Memory Power and Performance Management Maximum Performance 1333M
58. tion are also included on the DVD Dell Systems Service Diagnostics Tools Dell Systems Service and Diagnostics tools deliver the latest Dell optimized drivers utilities and operating system based diagnostics that you can use to update your system e eDocs The section includes PDF files for PowerEdge systems storage peripherals and Dell OpenManage software Dell Management Console DMC The Dell Management Console is a systems management console that enables systems administrators to discover and inventory devices on your network It provides functions such as health and performance monitoring of networked devices and patch management capabilities for Dell systems DMC differs from the IT Assistant management console described above in that with DMC value add plug ins that enable advanced functionality can be purchased and added to the base DMC product 45 PowerEdge R210 II Technical Guide Dell 16 3 Embedded Server Management The PowerEdge R210 Il implements circuitry for the next generation of Embedded Server Management It is Intelligent Platform Management Interface IPMI v2 0 compliant The optional iDRAC Integrated Dell Remote Access Controller is responsible for acting as an interface between the host system and its management software and the periphery devices These periphery devices consist of the power supplies the storage backplane the integrated SAS HBA or PERC 6 1 PERC H700 and the control panel with LCD di
59. tu Dian corintios Ta DO TUE DU 15 4 7 NIG Indicators 3d eb ede eee 15 4 8 Intermal Gassis VIEWS cess ete sace esse ae EHE RE Re SAC UR Gee MU DU Ad Lu 15 4 9 Ran ocior het Pede da EE esa REV dads sua EE TEN E decia se Rey A ciem P s aneedastaveads 16 4 9 1 Readyralis Static Ralls uacua satus antea Saas sua ta st Ss Sa a a 16 AAO FANS Me ES 16 411 LED Control Patel ci e da ed esae FEuu Fas ey exse ua E A aa 17 4122 OUT roS AT Ecce E LR EOD TC ER S TSA Dale SO SAA TSA Se AA TITAN 17 4 12 1 Cover Lateh ii eleme en ene A na cr ie Rd Ca aca RF D ERROR AA Du SOR VE d 17 ANA Bezeltcos usse te e ire exea N de rr teresa ue de Ie Tr aM Rude IE EN 17 2 12 3 Hard Dress saeua A SU A det Eu un tie 17 4 12 4 Trusted Platform Module TPM iacere rau e rrr haa ann o RR a ru rr 17 4 12 5 Power Switelt SeC Urity iioii ia vacan aa R axes e ex A RON AEREA ciet de duke 18 4 12 6 MINS CAL Se ooo dcbet o e edi ute AA EAS 18 41227 Secure Mode oreet renean leere gea et tee e etta aea at tat ate alu 18 AVS USB OV rr Paene x d unu Fox RAE RO 18 AANA DAI a a NS AO 18 4 14 1 Field Replaceable Units FRU oia eeziceus peu aora 18 4 15 User Accessible Jumpers Sockets and Connectors eee eren 18 5 Power Thermal ACOUSLIC LS eee ale ols ard EII 19 5 1 Power SUPPESA tad a Ee EEE sia 19 5 2 Power Supply Specifications sssini eter ra ater PARA FRE RE A ERE a 19 5 3 Heat DISTPACI N 200 ROC OC ERU RD ERA TR Ka De OY S M NO
60. tures and Indicators section in the About Your System chapter of the PowerEdge R210 Il Owner s Manual on Support Dell com for more information 4 4 Back Panel View and Features Figure 4 shows the back view of the PowerEdge R210 Il Figure 4 Back View See the Back Panel Features and Indicators section in the About Your System chapter of the PowerEdge R210 Il Owner s Manual on Support Dell com for more information 4 5 Power Button LED All Dell PowerEdge servers have a green LED integrated in the power button which indicates the system s power state 14 PowerEdge R210 Il Technical Guide Dell Figure 5 Power Button See the About Your System chapter of the PowerEdge R210 II Owner s Manual on Support Dell com for more information 4 6 System Status ID The System Status ID indicators are two LEDs one on the front panel of the system and one on the back panel These LEDs indicates the system state See the About Your System chapter of the PowerEdge R210 II Owner s Manual on Support Dell com for more information 4 7 NIC Indicators See the NIC Indicator Codes section in the About Your System chapter of the PowerEdge R210 II Owner s Manual on Support Dell com for more information 4 8 Internal Chassis Views Figure 6 shows the internal view of the PowerEdge R210 II server PowerEdge R210 II Technical Guide 15 Dell el ane JE X Figure 6 Internal Chassis View 4 9 Rails 4 9 1 ReadyRails Static
61. um and typical configurations of the PowerEdge R210 II are shown in Table 6 Table 6 Acoustical Specifications Minimum Configuration e 23 C Ambient o LwA UL LpA Prominent d Power perating Mode bel dBA HOMES Processor Hard Drives RAID bels dBA Supply Standby 2 8 16 None Idle 5 0 38 None inter 1 x 3 5 i3 2100 AR 1 x 250W None Active hard B 38 T 65W drives SUE d 5 0 38 None processor Typical Configuration e 23 C Ambient Operating Mode EUN E mios Buu it Processor Hard Drives pes RAID bels dBA Tones Supply Standby 2 8 16 None Intel Xeon Idle 3 2 40 None E3 1200 DN PERC product SATA 0 289 1X250W gg Active hard 5 2 41 None family drives 80W icai 5 2 41 None processor Definitions Standby AC Power is connected to power supplies but the system is not turned on Idle Reference 1507779 1999 definition 3 1 7 system is running in its OS but no other specific activity Active Hard Drives An operating mode per 1507779 1999 definition 3 1 6 Section C 9 of ECMA 74 9th ed 2005 is followed in exercising the hard disk drives Stressed Processor An operating mode per 1507779 1999 definition 3 1 6 SPECPower set to 50 loading is used LwA UL The upper limit sound power level LwA calculated per section 4 4 2 of ISO 9296 1988 and measured in accordance to ISO 7779 1999 22 PowerEdge R210 II Technical Guide Dell LpA Op A
62. zed appropriately and supported comprehensively 16 2 Server Management A Dell Systems Management and Documentation DVD and a Dell Management Console DVD are included with the product ISO images are also available A brief description of available content e Dell Systems Build and Update Utility SBUU Dell Systems Build and Update Utility assists in OS install and pre OS hardware configuration and updates Server Update Utility SUU This DVD has an inventory tool for managing updates to firmware BIOS and drivers for either Linux or Windows varieties OpenManage Server Administrator OMSA The OpenManage Server Administrator tool provides a comprehensive one to one one console to one server systems management solution designed for system administrators to manage systems locally and remotely over a network OMSA allows system administrators to focus on managing their entire network by providing comprehensive one to one systems management Management Console Dell IT Assistant ITA is also included as well as tools to allow access to our remote management products These tools are Remote Access Service for iDRAC and the Baseboard Management Controller BMC Utility e Active Directory Snap in Utility The Active Directory Snap in Utility provides an extension snap in to the Microsoft Active Directory This allows you to manage Dell specific Active Directory objects The Dell specific schema class definitions and their installa

Download Pdf Manuals

image

Related Search

Related Contents

実施計画    ADT 672 Digital Pressure Calibrator  Les quatre saisons de la rivière. Stage d`initiation  Manual de Usuario de TheKioske  Simpli Home WS5109-4 Instructions / Assembly  Condiciones Generales de Garantía Captadores Nº serie    CONFORT IMDA200 - Notice installation Détecteur de  SML-40-chassis Installation Manual v1.2  