Pyle PSPL05R

image

Contents

1. Windscreen LCD BB ME Ta REC FULL SYMBOL FUNCTION LCD 4 digits for measurement of db MAX Maximum hold MIN Minimum hold OVER Over upper limit of range UNDER under minimum limit of range FAST Fast response to time weighting SLOW Slow response to time weighting dBA A Weighting response to human sense C Weighting response to machine monitor 88 Range indicate 01 to 04 REC Recording data currently FULL Memory full HOLD Data hold function Low battery indicate Press the button one time for on off of backlight press the button continuously until the number 3 2 1 showing on the screen and then disappear for power off 8 8 Power on off and backlight button 2 Frequency weighting select button A A Weighting C C Weighting HOLD button 5 1 Data hold function Press button HOLD to freezes the reading in the display and press once more to exit the record Fi R 5 2 Data zero function Press the button continuously before power it on loosen the button when the display showing CL after the meter power on which indicates that the data in DATALOGGER has been deleted Level range and REC functions 6 1 Range select button Each time you press LEVEL button the level range will change between Lo 01 level Med 02 level Hi 03 level and Auto 04 level in the circular
2. PSPLOSR www pyleaudio com PYLE www pyleaudio com 1600 63RD STREET BROOKLYN NY 11204 718 535 1800 800 444 5671 IMPORTANT PACK CAREFULLY ORIGINAL CARTON IF POSSIBLE WE ARE RESPONSIBLE FOR DAMAGE INCURRED IN RETURNING ITEMS FOR REPAIR A LETTER STATING YOUR EXACT STREET ADDRES DAYTIME PHONE NUMBER AND THE PROBLEM YOU ARE EXPERIENCING SHOULD BE INCLUDED YOU MUST ALSO ENCLOSE A COPY OF THE ORIGINAL RECEIPT A SPROOF OF DATE OF PURCHASE 8 OPERATING PROCEDURE Power on the meter Press LEVEL button to select desired level base on UNDER or OVER do not appear on LCD Select dBA for general noise sound level and for measuring sound level of acoustic material Select FAST for instant sound and SLOW for average sound level Select MAX MIN button for measuring maximum and minimum noise level Hold the instrument comfortable in hand or fix on tripod and measure sound level at a distance of 1 1 5 meter 9 NOTICE i Do not store or operate the instrument at high temperature and high humidity environment ii When not in use for long time please take out the battery to avoid battery liquid leakage and cautery on the instrument iii When using the instrument in the presence of wind it is a must to mount the windscreen to not pick up undesirable signals iv Keep microphone dry and avoid severe vibration 1 INFORMATION Read the f
3. 6 2 REC record function 50 Press button hold to freeze data firstly then press REC to hold the data in meter s data base when the display show REC means operation successful Press hold again back to measure 6 3 Data reading function Press button REC continually until the display of symbol DATA on screen enter the model of reading 1 0 Test Data Data Number Press MAX and HOLD button to read data s date and time and REC button to read the next data Press FAST button to exit this model button Maximum and Minimum hold Press this button for one time to enter MAX MIN measurement MAX will appear on LCD maximum sound level will be captured and held until higher sound level is captured Press the button again MIN will appear on LCD and minimum sound level will be captured and held until new lower sound level is captured Press the button one more time to exit MAX MIN measurement FAST SLOW button time weighting selection FAST Fast sampling measurement 1 time per 125mS SLOW Slow sampling measurement 1 time per second 5 The time chip adjustment Press A C button and then power iton when SET symbol displays then loosen A C the meter will be under time adjustment mode at the time the display will 3
4. P seventh time the display showing year adjustment mode as below Press the SET UP for the eighth time will enter the model of initialization the display showing as below The display showing initialization of the time chip press HOLD to keep the setup time and date have returned to factory setup Keeping press the button STE if not intend to initialize When the battery is exhausted or replaced if the time can t be adjusted then please initialize the time chip first 6 4 03 80dB 130dB 04 30dB 130dB AUTO Frequency weighting Time weighting Microphone Display Display Update MAX hold MIN hold HOLD Alarm function Analog spar Data hold Date Time Power supply Power life Operation temperature and humidity Storage temperature and temperature Dimension Weight NAME AND FUNCTIONS FAST 125ms SLOW 15 1 2 inch electret condenser microphone 4 digits LCD display with a resolution of 0 1dB 2 times sec Hold the Maximum reading Hold the Minimum reading Hold the readings OVER is when input is more than upper limit of range UNDER is when input is less than upper limit of range Fast display of analog 20 times sec 50 sets Year month day Hour minute second One 9V battery OO6P or NEDA1604 or IEC 6F22 At least 30hours 0 C 40 C 10 RH 90 RH 10 C 60 C 10 RH 75 210mm x 55mm x 32 mm 230g
5. ollowing safety information carefully before attempting to operate or service the meter Use the meter only as specified in this manual Environment conditions Altitude lower than 2000 meters Relatively humidity lt 90 RH Operation Ambient 0 40 C Maintenance amp Clearing Repair or servicing not covered in this manual should be performed by qualified personnel Periodically wipe the case with a dry cloth Do not use solvents or eradicator on this instrument Safety symbols Comply with EMC 2 FUNCTIONS DESCRIPTION This Sound Level Meter is designed for noise project quality control illness prevention and cure and all kinds of environmental sounds measurement It is applied to the sounds measurement at factory school office traffic access and household etc This unit confirms to the 61672 1 CLASS2 for Sound Level Meters MAX amp MIN measurements Over range display Under range display A amp C Weighting FAST amp SLOW response 3 SPECIFICATION Standard applied 61672 1 CLASS2 Accuracy 1 4dB Frequency range 31 5HZ 8KHZ Dynamic range 50dB Level ranges 01 30dB 80dB 02 50dB 100dB Methods for each model as below Press level button to up adjust the data and max min button to down adjust the data press hold button to hold the data setup which you set and exit this model 6 CALIBRATION PROCEDURES Make the following switch
6. settings Frequency weighting A weighting Time weighting FAST Level range 02 50 100dB Insert the microphone housing carefully into the 1 2 inch insertion hole of the calibrator 94dB 1kHZ Turn on the switch of calibrator and adjust the CALL potentiometer of the unit 94 0dB is displayed NOTE All products are well calibrated before shipment Recommended recalibration cycle 1 year Acoustic Calibrator 7 MEASUREMENT PREPARATION Remove the battery cover on the back and put in one 9V battery Recover the back cover 8 When battery voltage drops below the operating voltage or battery aging this symbol will appear on LCD Replace the 9V battery When the AC adapter is used insert the plug of the adapter 3 50 into the DC 9V connector on the side panel 7 show the date as following DATE 28 08 2007 reading only Press the A C second time the display showing the time as following Time 16 58 18 reading only Press the A C third time the display showing minute adjustment mode as below Press the A C fourth time the display showing hour adjustment mode as below Press the SET UP fifth time the display showing date adjustment mode as below Press the SET UP for the sixth time the display showing 1 4 month adjustment mode as below Press the SET U