1. An event in the camera is when an Event Type is activated and causes certain actions to be performed The event type is the set of conditions that specifies how and when which actions will be performed This table describes how to setup action types and event type Event Type Manual Motion Schedule Action Type Alarm Input Trigger Detection Recording Pre Post Alarm ote 1 Record to PC only works when PC and IP camera are connected 2 Either Upload to FTP or Record to Network Storage can be selected to record event video to remote site 3 Up to 10 event types can be configured in the camera and up to 3 of these can be configured to upload images 28 3EverFocus EAN900 4 7 1 Event The settings relating to event occurrences such as settings for the event occurrence motion alarm and time mask can be configured on this page The Event page has 4 tabs Event tab the Motion tab the Alarm tab and the Time Mask tab ld EverFocus Event Motion Alarm Time Mask Event List Enable Name Event Type Actions Time Zone FT new event Motion Detection MD1 Trigger Alarm Always Press button to add an event condition To modify the event list click on the event and it will be highlighted Press button to modify the setting To remove an event from event list click on the event and 1t will be highlighted Press button to remove the event Check Enable checkbox to activa
2. Main Stream Format H 264 Resolution SXGA 1280x1024 Quality Highest Frame Rate Stream 2 Secondary TV Stream Enable TV Output Enable Format H 264 Resolution VGA 640x480 Quality Highest Frame Rate fps Stream 3 O Enable Format MPEG4 Resolution QVGA 320x240 Quality Highest Frame Rate Video Recording Setting Video Stream Stream 1 en Video File Format ARV Stream Setting The system can output 3 video streams simultaneously For each of them user can set compression format resolution quality and frame rate individually Stream 1 is main steam for live view Stream 2 1s secondary TV stream for TV output Stream 3 s used for small size view display Check Enable box to enable other streams for the different applications Format Select encode format from H 264 MPEG4 and MJPEG Resolution Stream 1 SXGA 1280 1024 SWXGA 1280 960 720P 1280 720 VGA 640480 QVGA 320 240 Stream 2 VGA 640 480 Check Enable TV Output to enable analog TV output for monitor Stream 3 QVGA 320 240 QCIF 176 120 SQVGA 160x128 SOCIF 128x96 Quality there are 8 types of quality please choose from Highest Higher High Middle Normal Low Lower Lowest 22 13 EverFocus EAN900 Frame Rate max 15 fps 128
3. 3EverFocus EAN900 Press Apply to apply the setting changes or Reset to reset without saving the change 4 8 3 SD Card fJ EverFocus Live Date Time Daylight Saving SD Card Maintenance System Info Event Recording Normal User Config Overwrite CON OFF Network SD Card Utility Capacity 964MB available 708MB used 26 56 Video _ Remove Press this button to remove or attach SD card with the camera powered on to avoid SD card damage Format Format SD Card Note All data saved on the SD card will be deleted when SD card is formatted Please do not turn the power of the EAN900 network camera off in the process of formatting FI Setup SD Card Notification Notification will be made via e mail when the remaining space of the SD memory card reached the value selected from the following 50 20 10 5 2 0 Note 1 When 50 is selected e mail notification will be made each time the remaining space reaches 50 20 10 5 2 and 0 2 E mail notification may not always be made at a very moment when the remaining space of the SD memory card reached the selected value Event Recording FTP backup only Event video will record to SD card when network is disconnected Normal Follow the event actions settings you have made in Event menu to record event video to SD card Overwrite Select ON for overwriting data when SD card memory is full Select 38 13 EverFocus
4. Live page Double click on the image to show a full screen display double click again or press ESC to return normal display 2 Press ee button to enter Setting page In Setting page there are 8 sections System Info User Config Network Video Audio User Event and System Please refer to 4 SETTING for further information 3 Press button to close EAN900 network page Video Stream 4 Video Stream Stream 1 Select Video Stream from Stream 1 Stream 2 and Stream 3 Please refer to 4 4 1 Multi Streaming for further information 13 EverFocus EAN900 View Size 5 View S ze 1280x720 You can select View size to either reduce or enlarge the image to the appropriate view size Select the view size for live images from 1280 1024 1280 960 1280 720 640 480 320 240 Digital Zoom 6 Digital Zoom le Le Press or button to enlarge reduce the displayed image max is X10 7 Record The record button 1s used to record the current video stream The location where the image file is saved can be specified in Setting gt User s Config Please refer to 4 2 User Config for further information ote Record segment is limited to 5 min If you need to do long time recording please set schedule recording For more details about schedule recording please see 4 7 Event 8 Snapshot The Snapshot button saves a snapshot of the video image c
5. Network Alarm IP Setting IP Type DHCP v IP Address 192 Subnet Mask Gateway j Primary DNS i Secondary DNS Username Password Port Setting HTTP Port 80 AIN The following information 1s required to configure the network settings Contact the network administrator or your Internet service provider e IP Type e IP address e Subnet mask e Gateway when using the gateway server router e Primary DNS Secondary DNS when using DNS e HTTP Port IP Setting IP Type 15 3EverFocus TANDO DHCP Configure the DHCP server not to assign the same IP addresses used for the other network cameras and PCs whose IP address is unique Refer to the network administrator for the settings of the server Default DHCP Static IP User can manually set the static IP for network connection PPPoE This is a DSL connection application ISP will ask user to input user name and password Note If PPPoE is used as IP type IP Utility software will not be able to detect the device IP address When not using DHCP enter the IP address of the camera Do not enter the IP address already used for PC or other network cameras Subnet Mask This field 1s to set the netmask for your network so as the IP camera will be recognized within the network Example 255 255 255 000 When DHCP s selected the DHCP server will assign this value automatically Gateway This
6. A A EEE 11 A E SVI I RTS DR 12 SER CON Oi taa 13 O ee ee ee re ee er ka 15 Bie NENO E INTERNER e io OE 15 A A A ne ee 17 a Ts AI D0 70 0 A E O uo IIS 18 A SMTP oirlo 19 4 3 5 Network Alarm reserved for POWwerCon ooooooonnnncccccnnnnnnnnnnnnononononanonononnos 21 FAN TDEO een OUT ee 21 4 4 1 M ll Streamme nenne 22 A A TR OF A E aces 23 A A I E esee A 24 AS AUDIO ee E E ee ren 26 MOSE ee o E O en er Re 21 EN ENT ee ee 28 AM VEN II ee ON EEN 29 A ee er 31 A o Ig E 32 O A o Ma ur 33 MAA A S E Pon A A 35 A o ee ee 35 A DAY 3 100 e e CUE A 37 A uo 38 E PP O RIA 40 SENUR A TIN Sra ea een 42 3EverFocus EAN900 1 INTRODUCTION The EAN900 network camera with a built in 1 3 mega pixel progressive scan CMOS offers crisp images with sharp definition and reduced motion blur that occurs n regular interlaced CCD EAN900 process multi streaming of H 264 or MPEG 4 MJPEG compression in full megapixel resolution which allows for optimization both in image quality and bandwidth efficiency Equipped with a SD card slot EAN900 offers another way to record and manage your video and can provide uninterrupted recording when network system 1s down Beside EAN900 is a Day and Night Mega pixel camera with IR cut filter The EAN900 high performance megapixel network camera is unquestionably the best choice to meet your need for professional video surveillance 2 FEATURES Oo 1 3 mega pixel 1 3 progressive scan CMOS sens
7. EAN900 OFF for not overwriting SD card data Press Apply to apply the setting changes or Reset to reset without saving the change SD Card Utility The total size and available size of the SD memory card will be displayed Depending on the state of the SD memory card the size indications will differ as follows Indication Description Capacity MB available MB used Before formatting the SD memory card t 1s necessary to press button Once button s pressed button will be shown for user to insert the SD card back Press button to format SD card Obtain images on the SD memory card l Access the camera using the Windows command prompt or FTP client software The window with the user name and password entry fields will be displayed 2 Enter the user name whose access level s 1 Administrator and 1ts password Log in the camera 3 A directory of all saved data will be displayed You are now ready to obtain images from SD card Notes 1 It is impossible to access the SD memory card in the process of formatting 2 All data saved on the SD memory card will be deleted when the SD memory card is formatted 3 Do not turn the power of the camera off in the process of formatting 39 13 EverFocus EAN900 4 8 4 Maintenance sa m lt I O A S Date Time Daylight Saving i SD Card Maintenance Maintenance Server Reboot the IP camera Resets all parameter except the IP pa
8. by clicking on button then direct to the folder to be exported File size Able to limit the size of the single recording file in minutes When the single recording file size exceeds the time you set system will create a new file to continue recording Overwrite Select ON for overwriting recording snapshot file when the disk storage capacity 1s full If the remaining hard disk capacity is less than MB enter the value you wish to set between 50 2000 system will stop recording or start overwriting Press Apply to apply the setting changes or Reset to reset without saving the change Language Setting Language Select the language to be displayed in web page Default language 1s English To add a new language which is not listed in the original configuration press the Browse button to locate the new language file evb and then click the Load button Note Upload a new language file will reboot system automatically Please reconnect IP camera after reboot Press Apply to apply the setting changes or Reset to reset without saving the 14 13 EverFocus EAN900 change 4 3 Network The network settings and the settings relating to Network DDNS Bandwidth SMTP FTP and Network Alarm can be configured on this page The Network setup page has 5 tabs of the Network tab the DDNS tab the SMTP FTP tab and the Network Alarm tab 4 3 1 Network SJ EverFocus Network DDNS Bandwidth SMTP FTP
9. 0 x 1024 max 15 fps 1280 x 960 max 20 fps 1280 x 720 max 30 fps 640 x 480 Press Apply to apply the setting changes or Reset to reset without saving the change Video Recording Setting User can set video recording by selecting one of the enabled video streamings This will allow user to view live images as well as to record video of the other video streaming Video Stream Select video recording stream from any enabled stream Video File format Recording file will be saved as AVI or ARV select which file format to be used Press Apply to apply the setting changes or Reset to reset without saving the change 4 4 2 Camera a m lt 7 O A S Multi Streaming Camera Advanced Camera Setting Brightness 0 Ca 104 Contrast 0 zzz j 100 Sharpness 0 z7 j 100 Flip ON OFF Mirror O ON OFF D N Mode Auto v Apply Reset 23 13 EverFocus EAN900 Camera setting Brightness to increase or decrease contrast value of images It s adjustable from 0 100 Contrast to increase or decrease contrast value of images It 1s adjustable from 0 100 Sharpness to increase or decrease sharpness value of images It s adjustable from 0 100 Flip Select ON or OFF to flip the video Mirror Select ON or OFF to horizontally inverse the video D N mode Select Auto Color or BW for Day Night function Auto Automatically switch images from color to B W when
10. 24 13 21 User userl 192 168 12 55 login 2008 06 24 13 00 34 User userl 192 168 12 66 login 2008 06 24 11 23 57 User user1 192 168 12 66 login 2008 06 24 11 23 48 User user1 192 168 12 66 login 2008 06 24 11 22 21 User user1 192 168 12 55 login 2008 06 24 11 21 54 User user1 192 168 12 55 login 2008 06 24 11 19 Boot 2008 06 24 11 19 System reboot by ITSELF LOCAL HOST 2008 06 24 11 16 Firmware is upgraded by user1 192 168 12 55 2008 06 24 11 16 37 User user1 192 168 12 55 login 2008 06 24 11 15 46 User userl 192 168 12 55 login 2008 06 24 08 55 18 User user1 192 168 12 61 login 2008 06 24 08 55 07 User user1 192 168 12 61 login 2008 06 24 08 54 59 User user1 192 168 12 61 login System Log Date Time displaying date and time of the log Log message all information and event message including login user s IP reboot firmware upgrade load factory default configuration reset and event detected System will keep the newest 256 records Press button to export system log into txt file and select the location where the exported log file will be saved to 12 13 EverFocus EAN900 4 2 User Config Live view configuration is to be set by user Each login user can make his her own settings for the following items F EverFocus User Config Text Setting Cl Machine Name O Date Time O Frame Rate Red 128 Foreground Color Green 128 B
11. 26982380 www everfocus com tw USA Office 1801 Highland Ave Unit A Duarte CA 91010 U S A TEL 1 626 844 8888 FAX 1 626 844 8838 www everfocus com USA N Y Office 415 Oser Avenue Unit S Hauppauge NY 11788 Tel 631 436 5070 Fax 631 436 5027 www everfocus com Your EverFocus product is designed and manufactured with high quality materials and components which can be recycled and reused electronic equipment at their E your local community waste collection recycling centre In the European Union there are separate collection systems for used electrical and electronic product Please help us to conserve the environment we live in Ihr EverFocus Produkt wurde entwickelt und hergestellt mit qualitativ hochwertigen Materialien und Komponenten die recycelt und wieder verwendet werden k nnen Dieses Symbol bedeutet dass elektrische und elektronische Ger te am Ende ihrer Nutzungsdauer vom Hausm ll getrennt entsorgt werden This symbol means that electrical and end of life should be disposed of separately from your household waste Please dispose of this equipment at China Office Room B 05D 1 KESHI PLAZA Shangd Information Industry Base Haidian District Beijing China 100085 TEL 86 10 62973336 37 38 39 FAX 86 10 62971423 www everfocus com cn Europe Office Albert Einstein Strasse 1 D 46446 Emmerich Germany TEL 49 2822 9394 0 FAX 49 2822 939495 www everfocus
12. EAN900 User s Manual 3EverFocus Copyright EverFocus Electronics Corp Release Dec 2009 Rev D 3EverFocus EAN900 Product Name EAN900 EverFocus IP Network Cameras Model Number s EAN900 FCC Notice Declaration of Conformity Information This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential Installation This equipment generates uses and can radiate radio frequency energy and 1f not installed and used in accordance with the instructions may cause harmful interference to radio communications However there 1s no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user 1s encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver 1s connected Consult the dealer or an experienced radio TV technician for help Warning Changes or modifications made to this equipment not expressly approved by EverFocus or parties authorized by EverFocus coul
13. Focus EAN900 the Load button The settings will be restored to the previous configuration Upgrade Firmware Upgrade the EAN900 with the latest firmware Press Browse button to search firmware file Press Upgrade button to upgrade the firmware Note I Do not disconnect power to the unit during the upgrade The unit reboots automatically after the upgrade has completed 1 5 minutes 2 During upgrading process all event recording actions will be stopped It will continue to record after the camera is rebooted 41 3 EverFocus EAN900 5 SPECIFICATIONS CAMERA MN Pickup Device 1 3 Progressive scan CMOS 1 3 Megapixel Pixel Effective 1280 H x 1024 V 0 5 Lux F 1 2 Day amp Night IR cut filter Optional C CS mount manual DD control supported Video Output BNC socket composite 1 V p p 750 VIDEO STREAMING A AA Video Compression H 264 MPEG 4 M JPEG Max Video Resolution 1280x1024 Video Qualit 8 levels adjustable Up to 15fps at 1280x1024 AUDIO A Built in omni directional microphone not available for U S region Audio Input 3 5 mm stereo socket sensitivity 1 Vrms Audio Output 3 5 mm stereo socket sensitivity 1 Vrms at load of 10KOhm and 50pf Compression Method IMA ADPCM Pulse Code Modulation Operation Mode NETWORK AAA Interface 10Base T 100Base TX auto negotiation RJ 45 socket Support MDVMDI X auto crossover function Supported Protocols HTTP TCP IP UDP RTP RTSP FTP SMTP DHCP DNS DDNS NTP B
14. Press Apply to apply the setting changes or Reset to reset without saving the change 36 3EverFocus EAN900 4 8 2 Daylight Saving IJ EverFocus Set Daylight Saving O Enable Daylight Saving Start 1ST v Sunday ln January v Switch from To 00 00 End Sunday vw lin January w Switch from To 00 00 Set Daylight Saving Check Enable Daylight Saving checkbox to enable daylight saving Set the start time to dayl ght saving time Set the start week of daylight saving time 1 2 3 4 Last Set the start date of daylight saving time Sunday Monday Tuesday Wednesday Thursday Friday Saturday Set the start month of daylight saving time January February March April May June July August September October November December Set the starting time change of daylight saving time Choose the From time and End time when daylight saving starts Set the end time of daylight saving time Set the end week of daylight saving time 1 2 3 4 Last Set the end date of daylight saving time Sunday Monday Tuesday Wednesday Thursday Friday Saturday Set the end month of daylight saving time January February March April May June July August September October November December Set the ending time change of daylight saving time Choose the From time and End time when daylight saving ends 37
15. andwidth Control Min 64 kbps adjustable Max Client Limit 32 simultaneous clients ALARM AA Alarm Input 1 x input for dry contacts Normal Open Normal Closed adjustable Alarm Output 1 x dry relay contact Normal Open Normal Closed adjustable 70 VDC 200 mA max SERIAL INTERFACE OO RS 485 RS 485 interface bi direction half duplex functionality reserved EVENT MANAGEMENT Event Triggered By Notification Over Alarm input Manual trigger Motion detection and Schedule recording Trigger alarm output Send mail notification Upload video to FTP Record video to SD card Record video to PC and Network alarm Pre and Post alarm Buffer 48MB RAM reserved for pre alarm record up to 120 sec LOCAL STORAGE SD Card Secure Disk physical layer specification version 2 0 Supports SDHC Host Specification POWER Power Supply 12 VDC amp PoE Power cord with 5 5 mm cable socket 5 5 mm adapter cable 20 cm included in package 42 3EverFocus EAN900 Power Over Ethernet Yes PoE 802 3af 4 5W max 12VDC PHYSICAL OOO 500 g 1 102 LBS Dimensions 68 W x 57 H x 136 D mm 146mm D with BNC socket 2 7 W x 2 2 H x 5 4 D 5 7 D with BNC socket ENVIRONMENTAL Operating Temp 0 C 40 C 32 F 104 F lt 90 not condensing 43 f EverFo cus EAN900 EverFocus Electronics Corp Head Office 12F No 79 Sec 1 Shin Ta Wu Road Hsi Chi Taipei Taiwan TEL 886 2 26982334 FAX 886 2
16. count Description Password Authority Status user Administrator 1 o user2 Normal user 2 USER y ACTIVE M user3 Normal user 3 s GUEST m ACTIVE user4 Normal user 4 GUEST WM DISABLE w user Normal user 5 GUEST WM DISABLE w user6 Normal user 6 GUEST WM DISABLE w user Normal user 7 GUEST WM DISABLE v users Normal user 8 GUEST w DISABLE w userg Normal user 9 GUEST MW DISABLE w user10 Normal user 10 GUEST WM DISABLE w MC MC User Information Maximum 10 users can be set for using the IP camera The user information displays the authorized users and access levels e Supervisor Administrator a supervisor administrator has unrestricted access to the Setting menu and can determine the registration of all other users However administrator 1s not allowed to change supervisor s account and password e User a user can view the Live View page system info network video audio and adjust user config settings The user does not have access to the user event and system pages e Guest the lowest level of access which only allows the user access to the Live View page Note Please select Active in Status section to activate user account Press Apply to apply the setting changes or Reset to reset without saving the change 21 3EverFocus EAN900 4 7 EVENT
17. d void the user s authority to operate the equipment This device complies with part 15 of the FCC Rules Operation 1s subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation EverFocus Electronics Corp 12F No 79 Sec 1 Shin Ta Wu Rd His Chi Taipei Hsien Taiwan R O C EAN900 complies with CE and FCC 3EverFocus EAN900 About this document Allthe safety and operating instructions should be read and followed before the unit is operated This manual should be retained for future reference The information in this manual was current when published The manufacturer reserves the right to revise and improve its products All specifications are therefore subject to change without notice Safety Notice These limits are designed to provide reasonable protection This equipment generates uses and can radiated radio frequency energy and 1f not installed and used in accordance with the instructions may cause harmful interference to radio communications However there 1s no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user 1s encouraged to try to correct the interference by one or more of the followi
18. de Japan Office 1809 WBG Mar bu East 18F 2 6 Nakase Mihama ku Chiba city 261 7118 Japan TEL 81 43 212 8188 FAX 81 43 297 0081 www everfocus co jp Bitte entsorgen Sie dieses Gerat bei Ihrer rtlichen kommunalen Sammelstelle oder im Recycling Centre ver OCUS Helfen Sie uns bitte die Umwelt zu erhalten in der wir leben
19. dns com O WWW no Ip com Enable Check the box to enable DDNS setting Service ISP If you choose EverFocus DDNS server you can obtain a free account name from EverFocus www everfocusddns com Enter an IP Cam Account Name everfocusddns com Press LL Register Update button to register or update DDNS account If you wish to get a domain name from other DDNS provider it is necessary to configure Record ID FODN Username and password and register in DDNS server Refer to the web site for further information about the DDNS Press Apply to apply the setting changes or Reset to reset without saving the change 4 3 3 Bandwidth ld EverFocus Bandwidth Setting Max Bandwidth unlimited bps Max Client Limit 8 1 32 subsequent viewers will see a blank image Ll Bandwidth Setting Max Bandwidth Specify Unlimited 64 K 128 K 256K 512 K 1M 2M 4M 8M bps the maximum bandwidth that the camera is allowed to use on the 18 13 EverFocus EAN900 network This 1s a useful function when connecting the camera to busy or heavily loaded networks The default setting is Unlimited Max Client Limit enter a value here to restrict the number of clients accessing the camera This 1s useful f you need to save on bandwidth Up to 32 clients 1s allowed to see live video simultaneously Subsequent viewers will see a blank image Press Apply to apply the setting change
20. eset without saving the change 4 7 4 Time Mask IJ EverFocus Event Motion Alarm Time Mask Time Mask Setting Weekend Mask Name Weekend MI Sun Mon Tue CI Wed C Thu Fri Y Sat Start Time 02 00 EndTime 22 00 FullDay Time Mask Setting Time mask setting allows you to schedule event actions 33 03 EverFocus EAN900 Select Always for event action to be taken continuously Press button to add new time period Mask name Input a mask name for the new time period Check the check box for the day to be scheduled Sun Mon Tue Wed Thu Fri amp Sat Set the Start time and End time for time mask by clicking Up arrow or Down arrow Or simply press for a full day of event action Press button to remove a scheduled time period An example on how to set weekend as time mask 1s as follows Click from time mask setting l 2 Enter Mask name e g Weekend 3 Check Sun amp Sat boxes 4 Select Start time and End time or Full day Press Apply to apply the setting changes or Reset to reset without saving the change 34 3EverFocus 4 8 SYSTEM EAN900 Date Time Daylight Saving SD card and Maintenance settings can be performed on this page The System page has 4 tabs of the Date Time tab the Daylight Saving tab the SD card tab and the Maintenance tab 4 8 1 Date Time IJ EverFocus Date Time Day
21. field 1s to set the gateway for your network so the IP camera will be recognized within the network When DHCP is selected the DHCP server will assign this value automatically Primary DNS An IP address of DNS server that 1s provided by ISP Secondary DNS If your ISP provides you an IP address secondary DNS please set 1t here Username Enter User name of the account used only for PPPoE Password Enter Password of the account used only for PPPoE 16 3EverFocus EAN900 Press Apply to apply the setting changes or Reset to reset without saving the change Port Setting HTTP Port Port number for HTTP WEB communication Press Apply to apply the setting changes or Reset to reset without saving the change 4 3 2 DDNS IJ EverFocus Network DDNS Bandwidth 1 SMTPIFTP Network Alarm DDNS Setting O Enable Service ISP O www everfocusddns com IP Cam Name everfocusddns com Register Update O www sitelutions com O www dyndns com O www no ip com Record ID 0 FODN Username Password DDNS setting When accessing the camera via the Internet from the network environment of which the global IP address s obtained using DHCP the DDNS function is necessary To use the DDNS function it is necessary to connect to the dedicated DDNS server We offer 4 DDNS server providers as follow o www everfocusddns com 17 13 EverFocus EAN900 O www sitelutions com Oo www dyn
22. h 4 7 3 Alarm ld EverFocus Event Motion Alarm Time Mask Alarm Output Setting Contact Type N O Duration Time 5Sec Pre Post Alarm Setting Pre alarm Buffer 30 Post alarm Buffer 30 Re trigger Filter Setting Re trigger Filter 5 Sec Alarm Output Setting Contact Type Normal Close Normal Open Duration Time Select duration time of alarm output from 5 sec 10 sec 20 sec 30 sec 60 sec 2 min 3 min and 5 min Press Apply to apply the setting changes or Reset to reset without saving the change Pre Post Alarm Setting This function is used to check what happened immediately before and after a trigger e g 5 seconds before or after a motion has been detected 32 13 EverFocus EAN900 Pre Alarm Buffer Image saved internally n the server from the time immediately preceding the trigger Input the desired length of pre trigger buffer time It can be set up to 120 seconds Post Alarm Buffer Image saved internally in the server from the time immediately after the trigger Input the desired length of post trigger buffer time It can be set up to 120 seconds Press Apply to apply the setting changes or Reset to reset without saving the change Re trigger Filter Setting Re trigger Filter Set a re trigger filter time 1f another event 1s triggered during this time this triggered event will be gnored Press Apply to apply the setting changes or Reset to r
23. isplay the setup menu ld EverFocus AR EAN900 1 SJ Video Stream Stream 1 View Size 1280x720 Digital Zoom Ley Ley y li en Y 5 am Y DD lt Manual Control Trigger Event Reset Alarm 10 EAN900 3EverFocus ENG 4 1 System Info System information and system log check of the setup menu can be performed on this page The System Info page has 2 tabs Information tab and the Log tab 4 1 1 Information System Information Firmware version MAC address Video Type Model number unchangeable for reference only ld EverFocus L Information Log System Information Firmware Ver 1 0 42 MAC Address 00 ff 14 ff 00 ff Video Type MEGA PIXEL 1280x1024 User Config Model Name EANSOO Video DIRRRDE IE 3EverFocus EAN900 4 1 2 Log ld EverFocus Information System Log 2008 06 25 14 03 User userl 192 168 12 66 login 2008 06 25 10 42 49 User user1 192 168 12 66 login 2008 06 25 08 14 28 User user1 192 168 12 61 login 2008 06 25 08 05 28 User user1 192 168 12 61 login 2008 06 25 08 00 57 User user1 192 168 12 61 login 2008 06 24 16 26 34 User user1 192 168 12 66 login 2008 06 24 13 35 33 User user3 192 168 12 55 login 2008 06 24 13 33 59 User user2 192 168 12 55 login 2008 06 24 13 32 User user1 192 168 12 55 login 2008 06 24 13 21 User userl 192 168 12 55 login 2008 06
24. light Saving SD Card Maintenance Machine Name User Config Set Time Zone Time Zone Date U NTP Server LINE Set Date Time Manually Machine Name Setting EAN800A 1 0 0 33 GMT v Set Date Time Sync Enable NTP pool ntp org Time Sync Interval 14 47 37 E 1 Hour v Machine Name Setting Machine Name Enter the name of the camera The entered name will be displayed in the status display area Press Apply to apply the setting changes or Reset to reset without saving the change Set Time Zone Time Zone Select a time zone according to the location where the camera is 1n S SC 35 3EverFocus Ai Set Date Time Manually Date Click the calendar and pick the date Press lt lt to go previous year lt to go previous month gt to go next month and gt gt to go next year aa EEE Time Click on Hour Minute Seconds am pm then use up arrow to increase value and down arrow to decrease value Press Apply to apply the setting changes or Reset to reset without saving the change Set Date Time Sync Check Enable NTP checkbox to enable NTP server NTP server Time automatically adjusted by synchronizing with NTP server will be used as the standard time of the camera Sync Internal Select an interval 1 24 hours in 1 hour intervals of synchronization with the NTP server
25. lue AAA ZA En 128 Position Upper Left v Date Time Format Used in Text DUDO ADD Date Format mdiyyyy Time Format 24 Hours O 12 Hours Recording Snapshot Export Setting Cl Enable Event Recording to PC Export Folder ca Ly File Size 1 Min Overwrite OON OFF If the remaining hard disk capacity is less than 50 MB 50 2000 system will stop recording or start overwriting Language Setting Language English y Browse JL upload Upload language file lt Text Setting Check the box for text of Machine name Date Time or Frame Rate to be displayed on the screen Text Color Foreground Color Select the foreground color of text to be displayed by moving the slide bar between Red Green and Blue until your desire color is obtained Position Select the position where the text will be displaying from Upper Left Lower Right Lower Left Press Apply to apply the setting changes or Reset to reset without saving the change Date Time Format Used in Text Select Date Time Format from the following options 13 f EverFocus EAN900 rege T me Format 24 Hours or 12 Hours Press Apply to apply the setting changes or Reset to reset without saving the change Recording Snapshot Export Setting Enable Event Recording to PC Allow event video recorded to users PC 1f any events have been set to record to PC Export folder Select Export folder
26. ng measures Reorient or relocate the receiving antenna Increase these separations between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help The changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment To reduce risk of fire or electric shock do not expose this appliance to rain or moisture Do not attempt to disassemble the appliance To prevent electric shock do not remove screws or covers There are no user serviceable parts inside Contact qualified service personnel for maintenance Handle the appliance with care Do not strike or shake as this may damage the appliance Do not use strong or abrasive detergents when cleaning the appliance body Use a dry cloth to clean the appliance when it is dirty When the dirt is hard to remove use a mild detergent and wipe gently 3EverFocus EAN900 Do not operate the appliance beyond 1ts specified temperature humidity or power source ratings Do not use the appliance in an extreme environment where high temperature or high humidity exists Use the appliance at temperature within 0 C 40 C 32 104 and a humidity below 90 The input power source for this appliance s 12 VDC amp PoE A Use only the recommended power supplies P
27. o the FTP server used to transmit the alarm images can be configured FTP Server Enter the IP address or the host name of the FTP server FTP Port Enter the port number for FTP server Default 1s 21 Recording Path Assign the recording path User Name Set FTP User s name Password Set FTP password PASV mode Check to enable Passive mode normally enable Passive mode When failed to establish the connection uncheck PASV mode Test FTP Server Press button to send a testing file to the assigned FTP server Press Apply to apply the setting changes or Reset to reset without saving the change 20 3EverFocus EAN900 4 3 5 Network Alarm reserved for PowerCon fJ EverFocus Network Y DDNS Bandwidth SMTP FTP Network Alarm Set Network Alarm Protocol UDP E Port No 1600 Unique ID 0000000001 Server 1 192 168 1 1 Server2 192 168 1 1 Server 3 192 168 1 1 Set Network Alarm This function is reserved for PowerCon software for the detail setting please refer to PowerCon network alarm protocol 4 4 Video The settings relating video such as streaming camera OSD can be configured on this page The Video page has 3 tabs the Multi streaming tab Camera tab and the Advanced tab 21 13 EverFocus EAN900 4 4 1 Multi Streaming a m lt O n O A S uv Multi Streaming Camera Advanced Stream Setting Stream 1
28. or with high sensitivity o Built in H 264 MPEG 4 and MJPEG digital signal output at 1280x1024 image size with up to 15fps H 264 MPEG4 MJPEG multi stream output for simultaneous live monitoring and high resolution recording Oo Power over Ethernet PoE IEEE 802 3af Oo True Day Night function with ICR module Oo User friendly Smart Event Wizard for Event Schedule Alarm recording to client PC or SD card o Built in SD memory card slot for local storage and support SD High Capacity Built in digital Motion Detection function O Two way audio 3 ACCESSING THE CAMERA MENU Step 1 Start an Internet Explorer browser Step 2 Enter the IP address or host name of the camera in the Location Address field of your Internet Explorer browser Please refer to EAN900 Installation Guide for how to find the IP address Step 3 Input Username and Password Default Username is user1 and default password s 11111111 Step 4 Click Login button Step 5 You might be required to download Active X which 1s required to view 10 13 EverFocus EAN900 camera video Please click Yes Step 6 Congratulation You should be able to see the live image now 13 IJ EverFocus EAN900 1 0 42 12 24 2008 14 49 Fps 10 15 E E ELE 14 1 Video Stream 4 Stream 1 v View Size 5 1280x720 v Digital Zoom 6 ie Ley 7 Manual Control 11 L Reset Alarm 12 1 Press button to display the
29. ower supplies must comply with the requirement of the latest version of IEC60950 1 Substitutions may damage the unit or cause a fire or shock hazard Electrostatic sensitive device Use proper CMOS MOSFET handing precautions to avoid electrostatic discharge A Installation should be performed by qualified service personnel only in accordance with the National Electrical Code or applicable local codes Terms and Trademark Ethernet Internet Explorer Linux Microsoft Windows WWW are registered trademarks of the respective holders Other product names appearing in this User s Guide may be trademarks or registered trademarks of their respective holders Java and all Java related logos and trademarks are trademarks or registered trademarks of Sun Microsystems Inc in the United States and other countries Support If the unit ever needs repair service the customer should contact the nearest EverFocus Electronics Corp Service Center for return authorization and shipping instruction About AC Adaptor Specifications for AC adaptor Power Supply 12VDC 1 A Power Output 12VDC 1 A Operating Temperature 0 40 32 104 External Dimensions 56 mm x 68 mm x 101 mm 2 24 x 2 72 x 4 04 J EverFocus EAN900 TABLE OF CONTENTS Pe TINT ROO TION orn I ETA 6 2 EA UIE ccecaccsccccnsevuxsseroueveccesanestusuctesssssesseass RD aka aa E NR 6 3 ACCESSING THE CAMERA MENU css iii 6 A RA 10 EL SS STE MINE UNO ee EE 11
30. rameters to the original factory settings Resets all parameter to the original factory settings Save Load Configuration Server Save all configuration to a config file Use a saved config file to return the unit to a previous configuration Upgrade Firmware Upgrade the EAN850A with the latest firmware Note Do not disconnect power to the unit during the upgrade The unit reboots automatically after the upgrade has completed 1 5 minutes 2008 07 03 System Info rn Maintenance Server Reboot The unit s rebooted without changing any of the settings Use this method by pressing Reboot button 1f the unit 1s not behaving as expected Restore The unit is restarted and most current settings are reset to the factory default values by pressing Restore button The only settings saved are e IP setting e DDNS setting Default The Default button should be used with caution Pressing this button will return all of the camera s settings including the IP address to the factory default values The camera will then have to be re installed Save Load Configuration Server To take a backup of all of the configurations press Save to save all configurations to a config file If necessary 1t 1s then possible to return to the previous settings 1f the settings are changed and there s unexpected behavior Press the Browse button to locate the saved config file see above and then click 40 3Ever
31. s 1 15s or 1 30s for night mode Press Apply to apply the setting changes or Reset to reset without saving the change Video Out Setting Video Out Format Select the video output format of NTSC or PAL for analog TV output usage Press Apply to apply the setting changes or Reset to reset without saving the change 23 13 EverFocus EAN900 4 5 Audio The EAN900 camera can transmit audio to other clients using a built in microphone or connecting to external microphone to play audio received from other clients via connected speakers This section describes how to configure the basic audio settings fJ EverFocus Audio Audio O Enable Audio Audio Input External Audio Input L Audio Input Volume 3 MC MC Audio Check Enable Audio box to enable audio function Audio Input Audio from an internal microphone or a line source can be connected to the Audio connector of EAN900 The audio source can be selected from Internal Microphone External Audio Input L and External Audio Input R ote icrophone is not available for U S region Audio Input volume Adjust the Audio Input Volume for the audio input devices connected to the camera 1f there are problems with the sound input being too low or high Press Apply to apply the setting changes or Reset to reset without saving the change 26 13 EverFocus EAN900 4 6 USER IJ EverFocus User User Information Ac
32. s or Reset to reset without saving the change 4 3 4 SMTP FTP 53 EverFocus Network DDNS Bandwidth SMTP FTP Network Alarm Set SMTP SMTP Server SMTP Port 25 O Authentication User Name Password Receiver Address Sender Address Send Test Email use to separate addresses Set FTP FTP Server FTP Port Recording Path User Name Password O PASV Mode Test FTP Server oo System Info MC A Set SMTP The settings relating to the mail server used to send the e mail notification from the camera to predefined addresses via SMTP can be configured SMTP Server Enter the IP address or the host name of the SMTP server used to send e mails SMTP Port Enter the port number for SMTP Default 1s 25 19 03 EverFocus EAN900 Authentication Check the box f the SMTP server requires Authentication user password User name Input the login user ID 1f the SMTP server requires Authentication Password Input the password 1f the SMTP server requires authentication Receiver Address Input the e mail address for receiving e mail message when the EVENT is enabled and triggered Please use 5 to separate address Sender Address Input sender s e mail address so that receiver can recognize the sender when an event message 1s sent out Send Test Mail Press button to send a testing mail to the assigned address Set FTP The settings relating t
33. t 7 Select Always for time mask For detail about Time Mask please refer to 4 7 4 Time Mask 8 Click to save this event in event list 4 7 2 Motion fJ EverFocus Live Event Motion Alarm Time Mask Motion Detection Left button click Draw line Left button double click i Connect to first point Ne Right button click A Clear all polygon Update image Kind AreaName fm Mm ms is o Enable O O O O O Sensitivity 5 y 5 y 5 y 5 y 5 y Motion Detection User can define the motion area to be detected by left clicking the mouse to draw lines Every click is an end point of the line When the detection area is formed double click the mouse to have all the lines connected To remove the selection simply right click the mouse the selected polygon will be deleted Press Update Image to update the current image Press to have the entire screen selected for motion detection Press to clear all selections Press and click on the polygon to erase that polygon 31 13 EverFocus EAN900 There are 5 motion trigger areas which can be distinguished by 5 different colors Check Enable checkbox to enable event act on For each of them you can set the event action to be activated Event action can be set n Event section Moreover you can set the Sensitivity level for motion tr ggered by selecting from 1 low 2 3 4 5 6 7 8 9 to 10 hig
34. te event actions when the event occurs in the specified time zone Event List Enable Name Event Type Actions Time Zone new event Motion Detection MD1 Tr gger Alarm Always i motion Motion Detection MD1 Record to PC Always 29 3EverFocus EAN900 To change the priority of events click on the event and it will be highlighted Press or button to move between events The event that has highest priority w ll be act vated f rst Press Apply to apply the setting changes or Reset to reset without saving the change This example describes how to set the camera to upload images to FTP when someone press Manual trigger button Enter Event Name Event 1 Add Event Type Actions Alarm Input Trigger Alarm Manual Trigger send Mail Notification Motion Detection Upload to FTP schedule Recording Record to SD Card Record to PC Network Alarm Enable Pre alarm Buffer Enable Re trigger Enable This Event Event Rule When Manual Trigger happens Camera Upload to FTP Time Mask Always 1 Click button in Event page 2 Enter an event name for the event e g Event 1 3 Select Manual Trigger as event type 4 Select Upload to FTP as action type 30 E 3EverFocus TANID 5 Check Enable Pre alarm Buffer and Enable Post alarm Buffer For pre and post alarm buffer setting please refer to 4 7 3 Alarm 6 Check Enable This Even
35. the illumination is under 15 Lux Color Always fix images n color mode BW Always fix images n Black White mode 4 4 3 Advanced a m O J Q A E u Multi Streaming Camera Advanced Advanced Setting LENS Setting LENS DC v IRIS Level L CZI H q LER ae ane White Balance Setting White Bal Auto v i ta _ e Apply Reset Video Out Setting Video Out Format NTSC v _ Apply Reset HEIZEN User Config MC 24 3EverFocus EAN900 Advanced Setting Lens Setting LENS Select DC or Fixed of the lens type used for camera DC DC driven Lens Fixed Manual Lens IRIS Level to manually adjust IRIS level of Lens when selecting DC driven Lens It 1s adjustable from 0 100 White Balance Setting White Bal Select the white balance modes of Auto or Custom to apply the light sources When selecting Custom mode please press Calibration to automatically adjust the white balance value to apply the specified environment Press Apply to apply the setting changes or Reset to reset without saving the change Exposure Setting Adjustable for Manual Lens only Auto Exposure Enable or disable to automatically adjust the exposure Max exposure time for Day mode Select the exposure time value from 1 5s 1 6s 2 15s 1 10s 1 15s or 1 30s for day mode Max exposure time for Night mode Select the exposure time value from 1 5s 1 6s 2 15s 1 10
36. urrently being displayed The location where the snapshot data is saved can be specified in Setting gt User s Config Please refer to 4 2 User Config for further information 9 Play Audio Transmit Audio Ci Click the Play Audio and Transmit Audio buttons to switch the sound off and on for the speaker and microphone respectively 10 Manual Control Reset Alarm Reset Alarm Press Reset Alarm button to reset alarm output remotely 03 EverFocus EAN900 11 Manual Control Trigger Event Trigger Event Press Trigger Event button to trigger an event directly from live view page and event actions will be effective if they have been set in Event menu Please refer to 4 7 1 Event 12 Manual Control Reset Alarm Press Reset Alarm button to reset alarm output remotely 13 Status Display The name of the camera whose settings currently being configured current date time and current frame rate will be displayed 14 Event signals ai RR Alarm Motion When an alarm or motion event s triggered a signal icon will flash to alert user The first con 1s for alarm event and rest of the 5 icons are for motion event The motion event icons which differed by colors correspond to the motion trigger areas you have set in Motion menu Please refer to 4 7 2 Motion for detailed information about Motion setup 3EverFocus 4 SETTING Click this button to d

Download Pdf Manuals

image

Related Search

Related Contents

Cliquez là - Laetitia bloud  USER'S MANUAL - TC Electronic  Untitled - Ige-XAO  Rinnai R50LSI User's Manual  Lorex LIVE Ping  BTS – CONCEPTION et INDUSTRIALISATION en  

Copyright © All rights reserved.
Failed to retrieve file