1. 4 1 SC825 Chassis Manual 4 2 Control Panel Buttons There are two push buttons located on the front of the chassis These are in order from left to right a reset button and a power on off button e Reset The reset button is used to reboot the system e Power The main power switch is used to apply or remove power from the power supply to the server system Turning off system power with this button removes the main power but keeps standby power supplied to the system Therefore you must unplug system before servicing 4 3 Control Panel LEDs The control panel located on the front of the SC825 chassis has five LEDs These LEDs provide you with critical information related to different parts of the system This section explains what each LED indicates when illuminated and any correc tive action you may need to take e Power Failure When this LED flashes it indicates a power failure in the power supply d Overheat Fan Fail When this LED flashes it indicates a fan failure When continuously on not flashing it indicates an overheat condition which may be caused by cables obstructing the airflow in the system or the ambient room temperature being too warm Check the routing of the cables and make sure all fans are present and operating normally You should also check to make 4 2 Chapt
2. Warnung Bei der Installation des Produkts die zur Verf gung gestellten oder benannt Anschlusskabel Stromkabel und Netzteile Verwendung anderer Kabel und Adapter kann zu einer Fehlfunktion oder ein Brand entstehen Elektrische Ger te und Material Safety Law verbietet die Verwendung von UL oder CSA zertifizierte Kabel UL oder CSA auf der Code f r alle anderen elektrischen Ger te als Produkte von Supermicro nur bezeichnet gezeigt haben Advertencia Al instalar el producto utilice los cables de conexi n previstos o designados los cables y adaptadores de CA La utilizaci n de otros cables y adaptadores podr a ocasionar un mal funcionamiento o un incendio Aparatos El ctricos y la Ley de Seguridad del Material proh be el uso de UL o CSA cables certificados que tienen UL o CSA se muestra en el c digo de otros dispositivos el ctricos que los productos designados por Supermicro solamente 2 18 Chapter 2 Warning Statements for AC Systems Attention Lors de l installation du produit utilisez les bables de connection fournis ou d sign L utilisation d autres cables et adaptateurs peut provoquer un dysfonctionnement ou un incendie Appareils lectrom nagers et de loi sur la s curit Mat riel interdit l utilisation de UL ou CSA c bles certifi s qui ont UL ou CSA indiqu sur le code pour tous les autres appareils lectriques que les produits d sign s par Superm
3. LED State Specification D3 on Overheat drive failure LED indicator Red light Flashing Buzzer On if activated C 9 SC825 Chassis Manual C 8 Rear Connectors and LED Indicators Figure C 5 Rear Connectors and LEDs Rear SAS SATA Connectors Rear SAS Drive Rear SAS Drive Connector Number Connector Number SAS 0 J1 SAS SATAHDD 0 SAS 4 J9 SAS SATA HDD 4 SAS 1 J2 SAS SATA HDD 1 SAS 5 J11 SAS SATA HDD 5 SAS 2 J3 SAS SATA HDD 2 SAS 6 J13 SAS SATA HDD 6 SAS 3 J4 SAS SATA HDD 3 SAS 47 J15 SAS SATA HDD 7 Rear LED Indicators Rear LED Hard Drive Activity Failure LED SAS 0 D12 D5 SAS 1 D13 D6 SAS 2 D14 D7 SAS 3 D15 D8 SAS 4 D18 D19 SAS 5 D21 D20 SAS 6 D22 D23 SAS 7 D25 D26 Appendix C BPN SAS 825TQ Backplane Specifications Notes SC825 Chassis Manual Disclaimer cont The products sold by Supermicro are not intended for and will not be used in life sup port systems medical equipment nuclear facilities or systems aircraft aircraft devices aircraft emergency communication devices or other critical systems whose failure to per form be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such products for use in such ultra hazardous applications it does so entirely at its own risk Furthe
4. R700W Redundant PWS 702A IR 100 240V 60 50Hz 10 4Amp SC825 Chassis Manual SC825 Series MFR Part Rated AC Voltage AC Input DC Input Volt age DC Output 5V standby 12V 5V 3 3V 12V 710W DC DC Power Supply PWS 711 1R Voltage Range 36V to 75V 24A 11A Nominal Voltage 48V 4 Amp 59 Amp 30 Amp 20 Amp 0 6 Amp R720W Redundant PWS 721P 1R 100 240 V 50 60 Hz 4 9 Amp 3Amp 5V standby 59 Amp 12V 740W PWS 741P 1R 100 240 V 50 60 Hz 9 3 5 Amp 4 Amp 5V standby 61 7 Amp 12V B 2 Appendix A Chassis Cables Appendix A SC825 Chassis Cables A 1 Overview This appendix lists supported cables for your chassis system lt only includes the most commonly used components and configurations For more compatible cables refer to the manufacturer of the motherboard you are using and our Web site at www supermicro com A 2 Cables Included with SC825TQ Universal 1 0 Chassis SC825TQ R700U Part Type Length Description 8 pin to 8 pin ribbon cable for CBL 0157L Cable 9 SGPIO PB free CBL 0087 Ribbon 20 16 pin to 16 pin ribbon cable for Round control panel CBL 0179L Cable 70 cm SATA cable Cable e Two regional power cords CBL 0180L 01 SATA rois oul oo e ied to minimize airflow interference A 3 Cables Included with SC825TQ Chassis SAS SATA SC825TQ R700RC2 R700
5. 710W single 720W redundant or 740W Redundant In the unlikely event your power supply fails replacement is simple and can be accomplished without tools Air Shroud Air shrouds are shields usually plastic which conduct the airflow directly to where it is needed Always use the air shroud included with your chassis 3 3 Where to get Replacement Components Although not frequently you may need replacement parts for your system To ensure the highest level of professional service and technical support we strongly recommend purchasing exclusively from our Supermicro Authorized Distributors System Integrators Resellers A list of Supermicro Authorized Distributors System Integrators Reseller can be found at http www supermicro com Click the Where to Buy link 3 2 Chapter 4 System Interface Chapter 4 System Interface 4 1 Overview There are LEDs on the control panel and the drive carriers to keep you constantly informed of the over all status of the system as well as the activity and health of specific components Most SC825 models have two buttons on the chassis control panel a reset button and an on off switch This chapter explains the meanings of all LED indicators and the appropriate response you may need to take UUUUUUUUGUUUUUGUUC CE JUCUCU SO0O000000000008 llo E3 eo Daanen
6. Diese Einheit ist zur Installation in Bereichen mit beschranktem Zutritt vorgesehen Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug Schloss und Schl ssel oder einer sonstigen Sicherheitsvorkehrung m glich Advertencia Esta unidad ha sido dise ada para instalaci n en reas de acceso restringido S lo puede obtenerse acceso a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s une zone d acc s r serv n est possible qu en utilisant un outil sp cial un m canisme de verrouillage et une cl ou tout autre moyen de s curit 2 9 xxx Chassis User s Manual Dan HW OY TIN LON nya nii TWA TW 02247 nma WW DRA mem ns ppna v 721 51135 DPE 7292 TNV 75 A dll Ga jl ias ll ola yanadi gi als Bla plaste JAS ya bib 5 Rana is el J pac dl Sa OL 5 zal Aba s sl sl c Uia y J aa ol JAE duel AA FIN SAGES JINEYA STET te x Y 7 He 7g ek Tz E SAA At AS TOO EI Wed Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een beperkte toegang Toegang tot dergelijke gebieden kunnen alleen verkregen worden door gebruik te maken van speciaal gereedschap slot en sleutel of andere veiligheidsmaatregelen Battery Handling A Warning There is the danger of explosion if the battery is replaced incorrectly
7. rona v arpn gx Ta 29901 172 299105 YW pis n130 nip D nn JI nan ONINT 1102 129705 nx yon MRI 55 9399 v mwaiwan moon pIo led Asus j y play ll Jac Alla 3 il Ge jas dlia dy Lal A iriall AS Al Ay caus d Les lll Le gl E all Liu L dla 4S LAN lala G y Aerial AL ll ja alii am Meer SHEA xxx Yen Sebo Hol EU 11 mele st Ss HN BASE ESS SHS NAE 16 ut az Y Hal upep 4230 AE US esr FAL I of Waarschuwing Er is ontploffingsgevaar indien de batterij verkeerd vervangen wordt Vervang de batterij slechts met hetzelfde of een equivalent type die door de fabrikant aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden 2 11 xxx Chassis User s Manual Redundant Power Supplies A Warning This unit might have more than one power supply connection All connections must be removed to de energize the unit REM TODAY MEEBO EIR BEEN TW AUDIE Lzy ORZA DIEUX TN TORE INEEN EEA V kr REES DT m ERUIT Be IE IR RUE TE I je Ee E V tz ARE ARA gt AAA EIA RA EN E de Warnung Dieses Ger t kann mehr als eine Stromzufuhr haben Um sicherzustellen dass der Einheit kein trom zugef hrt wird m ssen alle Verbindungen entfernt werden Advertencia Puede que esta unidad tenga m s de una con
8. standoffs Secure the motherboard to the chassis using the rounded Phillips head screws Do not exceed eight pounds of torque when tightening down the motherboard Secure the CPU s heatsinks and other components to the motherboard as described in the motherboard documentation Connect the cables between the motherboard backplane chassis front pan el and power supply as needed Also the fans may be temporarily removed to allow access to the backplane ports Figure 5 10 Chassis Standoffs 5 10 Chapter 5 Chassis Setup and Maintenance Add on Card Expansion Slot Setup SC825 chassis include I O slots for add on cards and expansion cards The number of cards you can use depends on your chassis model SC825 LP Provides 7 low profile add on card slots SC825U Provides 3 full height full length and 3 low profile card slots through a user defined universal expansion card Add on Expansion Card Slots Figure 5 11 SC825 LP model Add on Card Expansion Slot Setup in LP Low Profile Chassis SC825 chassis include slots for add on cards and expansion cards The number of cards you can use depends on your chassis model and motherboard model Installing Add on and Expansion cards in SC825LP Low Profile Chassis 1 Disconnect the power supply lay the chassis on a flat surface and open the chassis cover 2 Remove the screw holding the cover in place for each low profile add on ex pansion card slot y
9. 2 Open the chassis cover 3 With the illustrations facing the outside of the chassis place the shield into the space provided 4 Once installed the motherboard will hold the I O shield in place 5 8 Chapter 5 Chassis Setup and Maintenance Permanent and Optional Standoffs Standoffs prevent short circuits by securing space between the motherboard and the chassis surface The SC825 chassis includes permanent standoffs in locations used by most motherboards These standoffs accept the rounded Phillips head screws included in the SC825 accessories packaging Some motherboards require additional screws for heatsinks general components and or non standard security Optional standoffs are included to these mother boards To use an optional standoff you must place the hexagonal screw through the bottom the chassis and secure the screw with the hexagon nut rounded side up 5 9 SC825 Chassis Manual Installing the Motherboard 1 Review the documentation that came with your motherboard Become familiar with component placement requirements precautions and cable connec tions Open the chassis cover As required by your motherboard install standoffs in any areas that do not have a permanent standoff To do this A Place a hexagonal standoff screw through the bottom the chassis B Secure the screw with the hexagon nut rounded side up Lay the motherboard on the chassis aligning the permanent and optional
10. 7 ACT IN 5 ACT IN 3 ACT IN 2 8 ACT IN 6 9 ACT IN 7 Ground 10 Empty PC Connector Pin Definitions Pin Definition 1 Data 2 Ground 3 Clock 4 No Connection Appendix C BPN SAS 825TQ Backplane Specifications 8 and 9 Sideband Headers Sideband Headers The sideband headers are designated JP51 and JP52 For SES 2 to work properly you Pin Definition Pin Definition 2 SGPIO 1 Controller must connect an 8 pin sideband cable See SDIN ID SB6 the table to the right for pin definitions FC Backplane Addressing 4 SGPIO 3 GND SB2 SDOUT FC Reset 6 GND SB3 5 SGPIO SLOAD lC SDA 8 Backplane 7 SGPIO ID SB7 SCLOCK 1 C SCL 10 No Connec 9 No Connec tion tion 10 MG9072 Chip The MG9072 is an enclosure management chip that supports the SES 2 controller and SES 2 protocols 11 Upgrade Header The upgrade header is designated JP46 and is used for manufacturing purposes only 12 to 19 SAS Ports The SAS ports are used to connect the SAS drive cables The eight ports are designated 0 7 Each port is also compatible with SATA drives C 5 SC825 Chassis Manual C 7 Front Jumper Locations and Pin Definitions m JP36 q IE CO Jp29 SG Hauts JP38 Figure C 3 Front Jumpers Explanatio
11. Front Bezel E 5 21 Chapter 6 Rack Installation 6 1 OVEIVIEW ee 6 1 6 2 Unpacking the System nun 6 1 6 3 Preparing for Setup uir da tios 6 1 vii SC825 Chassis Manual Choosing a Setup Localia aa Rack E e General Server Pr cautions 2 Rack Mounting Considerations oooonnoccccnnnccccccnnoncnccnnonncnncnnannnnnnnono Ambient Operating Temperature sess Reduced AIM pr Mechanical Kosengen ceu petente honte Circuit Overloading ss Reliable Ground 5 3 0 A 6 4 Rack Mounting Instructions nos Separating the Sections of the Rack Rails Installing the Inner Rail Extension nnn ennen ennenensenneeeerennnenn Outer Rack Ra lls u a ot nr de Appendix A SC825 Chassis Cables Appendix B SC825 Power Supply Specifications Appendix C BPN SAS 825TQ Backplane Specifications viii Chapter 1 Introduction Chapter 1 Introduction 1 1 Overview Supermicro s SC825 2U chassis features a unique and highly optimized design The chassis is equipped with high efficiency power supply 1 2 Shipping List Please visit the following link for the latest shipping lists and part numbers for your particular chassis model http www supermicro com products chassis 1U chs 825 SC825 Chassis Model CPU HDD VO Slots Power Supply 740W SC825TQ R740LPB DP UP a Tes Ie Platnum Level SATA Redundant SC825TQ 720LPB DP UP 8x SAS SATA 7xLF 120
12. Part Type Length Description E 8 pin to 8 pin ribbon cable for CBL 0157L Ribbon 9 SGPIO PB free CBL 0087 Ribbon 20 16 pin to 16 pin ribbon cable for Round control panel CBL 0179L Cable 70 cm SATA cable Cable e Regional power cord CBL 0180L SATA E arous ce cee ae cae eee anon yan ied to minimize airflow interference A 4 Cables Included with SC825S2 Chassis SCSI C825S2 R700LP Part Type Length Description CBL 033L U320 Ribbon 9 23 cm ULTRA 320 PB FREE CBL 0179L Cable 70 cm SATA cable Cable 6 Regional power cord CBL 0063L Cable 20 SCSI Cable for SC811S 350 SC825S2 R560LP Part Type Length Description CBL 033L U320 Ribbon 9 23 cm ULTRA 320 PB FREE CBL 0179L Cable 70 cm SATA cable Cable 6 IDE 80 Wire cable for DVD ROM CBL 0063L Cable 20 Regional power cord A 3 SC825 Chassis Manual A 5 Compatible Cables These cables are compatible with the SC825 Chassis Alternate SAS SATA Cables Some compatible motherboards have different connectors If your motherboard has only one SAS connector that the SAS SATA cables must share use one of the following cables These cables must be purchased separately Cable Name SAS Cable Quantity 1 Part CBL 0175L Alt Name Big Four Description This cable has one SFF 8484 32 pin connector on one end and 4 SAS connectors 7 pins each at the other This cable connects from the host motherboar
13. and or its licensors and is supplied only under a license Any use or reproduction of this product is not allowed except as expressly permitted by the terms of said license IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES IN PARTICULAR SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE SOFTWARE OR DATA STORED OR USED WITH THE PRODUCT INCLUDING THE COSTS OF REPAIRING REPLACING INTEGRATING INSTALLING OR RECOVERING SUCH HARDWARE SOFTWARE OR DATA Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California USA The State of California County of Santa Clara shall be the exclusive venue for the resolution of any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product California Best Management Practices Regulations for Perchlorate Materials This Perchlorate warning applies only to products containing CR Manganese Dioxide Lithium coin cells Perchlorate Material special handling may apply See www dtsc ca gov hazardouswaste perchlorate WARNING Handling of lead solder materials used in this product may expose you to lead a chemical known to the State of California to cause birth defects and other reproducti
14. instalaci n antes de conectar el sistema a la red de alimentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation ANA pn NIN mmn 7159 nona nmm nx RP v AGUA une col AUS do gi Ud cas jill cul il MEE Ado Ads Ao 24 UE erred filo Waarschuwing Raadpleeg de installatie instructies voordat u het systeem op de voedingsbron aansluit 2 4 Chapter 2 Warning Statements for AC Systems Circuit Breaker A Warning This product relies on the building s installation for short circuit overcurrent protection Ensure that the protective device is rated not greater than 250 V 20 A poy hI COD LS RARE QI EURO EECH PRETO ERA 250 V 20 ASSEL SECH PEW BE EI CAR E ANGE RAAF 250V 204 wa BEZET IES GER En RE ERE ARTETA MEE tec RA ATE EE AAW 250V 204 Warnung Dieses Produkt ist darauf angewiesen dass im Gebaude ein Kurzschluss bzw berstromschutz installiert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A betr gt jAdvertencia Este equipo utiliza el sistema de protecci n contra cortocircuitos o sobrecorrientes del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protect
15. temperature of the room Therefore consideration should be given to installing the equipment in an environment compatible with the manufacturer s maximum rated ambient tempera ture Tmra Reduced Airflow Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised Mechanical Loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading Circuit Overloading Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern Reliable Ground A reliable ground must be maintained at all times To ensure this the rack itself should be grounded Particular attention should be given to power supply connec tions other than the direct connections to the branch circuit i e the use of power strips etc To prevent bodily injury when mounting or servicing this unit in a rack you must take special precautions to ensure that the system remains stable The following guidelines are provided to ensure your safety e This unit should be mounted at the bottom of the rack if it is the only unit in the rack e When mounting this unit in a partially filled rack load the rack from
16. 37 1491 uber 9 E slo uu Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale elektriciteitsvoorschriften Product Disposal DM Warning Ultimate disposal of this product should be handled according to all national laws and regulations SO BERE TOBE BERL DAA ID BURT SAC OEE DE LES E BEDS DUES Ex A es CT SA ES T gt Ex A S CT EDERT EU HIPH AKARE T e Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen xxx Chassis User s Manual Advertencia Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales Attention La mise au rebut ou le recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupres de l organisme comp tent 55 pro rms msn PINT nma ONNA NPD 3 n AT 231 PU DID P12 0 Agile dl ei gil ul jill are li y due Dele Ar al la ye All yal sie 73 51 e AES spud 3719 xp Wat B rde ue user Br cy Waarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming met alle nationale wetten en reglementen Hot Swap Fan Warning A Warning The fans might still be turning when you remove the fan assembly from the chassis Keep fingers screwdrivers and other objects away from th
17. Chassis Manual Table of Contents Chapter 1 Introduction 1 1 OVErVieW csi a A a A AAA 1 1 1 2 1 3 LA E nenne nennen 1 2 Peripheral BI vivos an ea ea 1 2 Other Features 1 2 SCSI Chassis Models rear nee hd 1 2 elle ue Ee Er ue EE 1 3 1 5 Returning Merchandise for Service 1 4 Chapter 2 Standardized Warning Statements for AC Systems 2 1 About Standardized Warning Statements nnen ennneneenenneneerenn 2 1 Warning Definitio Prsa nenne 2 1 Installation Instructions 2 4 A O 2 5 Power Disconnection Warning A 2 6 Equipment Installation oia Een 2 8 Resticted ANC rieron 9 2 9 Battery Handling es erer eei enr is 2 10 Redundant Power Suppli S anar saneren precandi R E seas 2 12 Backplane Voltage Helle aria 2 13 Comply with Local and National Electrical Codes nn 2 14 leet al Eet EE 2 15 Hot Swap Fan Warning uei tet ae 2 16 Power Cable and AC Adapter cc ccccsseeceeceeeeeeeeeeeaeeeeeseaeeeeeeeeaeeeeeeeaee 2 18 Chapter 3 Chassis Components 3 1 3 2 Overview COMPA Scaricare Re ar ce p RA ER 3 1 GIC 3 1 stre do CT 3 1 FANS 3 1 MountingRalls iiio e riot tp proto ain con CREE EUER 3 1 Power Supply vi Preface AIP SIMOUG anr 3 2 3 3 Where to get Replacement Components naan 3 2 Chapter 4 System Interface 4 1 Overview ra dede
18. If you are replacing a drive Locate the locking tab at the rear left hand side when viewed from the front of the DVD ROM drive Push the tab toward the drive and push the drive unit out the front of the chassis Insert the new drive unit in the slot until the tab locks in place Reconnect the data and power cables Replace the chassis cover replace the server in the rack if necessary and power up the system Replacing the DVD ROM and Front Panel SC825 chassis models include a slim DVD ROM and front port panel Use the instructions in this section in the unlikely event that you must replace any of these components DVD ROM Front Port Panel IT UUUUUUUUUUUUUUU 0000000 000000000000000 0000000 0000000 Figure 5 8 Install the DVD ROM and Front Panel 5 7 SC825 Chassis Manual 5 7 Installing the Motherboard UO Shield Figure 5 9 1 0 Shield Placement UO Shield The I O shield holds the motherboard ports in place Install the UO shield before you install the motherboard Installing the UO Shield Installing the 1 0 Shield 1 Review the documentation that came with your motherboard Become familiar with component placement requirements and precautions
19. RATITO gt EE gt EON LAA AAS de Warnung Das Installieren Ersetzen oder Bedienen dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o utilizar este equipo Attention ll est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s 1 TAIN ET May NW NY IR 3135 DN pap ppnnd RWI 3292 now nm Steal a Lans sl Sail auf al y Cale gall cils gall L any Of ay o H EUS da ZUR ate d AA AA MA EE MAS FMS su Chapter 2 Warning Statements for AC Systems Waarschuwing Deze apparatuur mag alleen worden geinstalleerd vervangen of hersteld door geschoold en gekwalificeerd personeel Restricted Area A Warning This unit is intended for installation in restricted access areas A restricted access area can be accessed only through the use of a special tool lock and key or other means of security This warning does not apply to workstations 77 AU BR pb COL METI ARE LC gi dUScbZRUEUCU3 3 TI AB HL RIE BEE GER TOMO LEIT 4D TER UL CO AH HANETT ga a Pr DUE LB E PH FREE ao LE are FRERE PERERA SIAE ERASE A A L E Je TR Be LAI BAA REEN HIE e Warnung
20. RC Part Type Length Description 8 pin to 8 pin ribbon cable for CBL 0157L Cable 9 SGPIO PB free CBL 0191L Cable 50 cm 20 pin to 20 pin cable for control panel CBL 0179L Cable 70 cm SATA cable Cable e Two regional power cords CBL 0180L ET e eos en Redes engine ied to minimize airflow interference A 1 SC825 Chassis Manual SC825TQ R720LP SC825TQ R720U Part Type Length Description e 5 8 pin to 8 pin ribbon cable for CBL 0157L Ribbon 9 SGPIO PB free SATA set of 4 70 59 48 38CM round CBL 0180L 01 SATA various S RA PBF CBL 0044L SATA 61cm SATA cable S S CBL 0082L SATA Y split SATA power adapter CBL 0296L Cord EN Fan extension cord SC825TQ R710LP Part Type Length Description a 8 pin to 8 pin ribbon cable for CBL 0157L Ribbon 9 SGPIO PB free Split CBL 0084 6 16 pin front control split cable cable CBL 0160L Cable Regional power cord CBL 0180L sima vaa 99tor SATA pables Tena var ied to minimize airflow interference SC825TQ R700LP Part Type Length Description d 8 pin to 8 pin ribbon cable for CBL 0157L Ribbon 9 SGPIO PB free CBL 0087 Ribbon 20 16 pin to 16 pin ribbon cable for Round control panel CBL 0979L Cable 70 cm SATA cable Cable e Two regional power cords CBL 0180L 01 ln ee E ied to minimize airflow interference A 2 Appendix A Chassis Cables SC825TQ 560LP
21. Replace the battery only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions iil LO RV Viilise E EUS TTD TUE IS BAO TET SOFT RTM A AMES AU ET ROEDEN PE BOUT BDE COR nic TE DTMAUT FEW Ex FB2U SE HUS S SATTE EI E HRABE oT Pee ile RY Th SA BE H E gt ra EC HATE E ARE gt HEEL A AUREA a n EI THIS BCE EAN EHEN 2 10 Chapter 2 Warning Statements for AC Systems Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers Attention Danger d explosion si la pile n est pas remplac e correctement Ne la remplacer que par une pile de type semblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta Reemplazar la bater a exclusivamente con el mismo tipo o el equivalente recomendado por el fabricante Desechar las bater as gastadas seg n las instrucciones del fabricante TIAN
22. SUPERO SC825 CHASSIS S DOC DICHT UE E e JJUUUU DO IC 000000000008086 o E ee Anand N 5500 TOBA sE 9999 q SIE 3 Se P IT T DOT HE I 2 Dl 2 oo CIOCOQOQGOOCOQOOCOCOCO OOCODOODOOOOOODO0 9 DODODODODCOUCODO 09 9 DODOOOOOOOOOOO0 9 OCOOOOOOOOOOOOOO 9 OOOOOOOOOOOOOOOx0 gt I i X 3 TR 3 2 I SC825TQ R720LPB SC825TQ R740LPB SC825TQ 710LP SC825TQ R720UB SC825TQ R700LP V B SC825TQ R700U V B SC825TQ 600LPB SC825TQ 563UB SC825TQ 563LPB SC825TQ 560L P V B SC825TQ 560U V B USER S MANUAL 2 0 SC825 Chassis Manual The information in this User s Manual has been carefully reviewed and is believed to be accurate The vendor assumes no responsibility for any inaccuracies that may be contained in this document makes no commitment to update or to keep current the information in this manual or to notify any person or organization of the updates Please Note For the most up to date version of this manual please see our web site at www supermicro com Super Micro Computer Inc Supermicro reserves the right to make changes to the product described in this manual at any time and without notice This product including software and documentation is the property of Supermicro
23. W Gold Level 4x FF 3x 720W SC825TQ 720UB DP UP 8x SAS SATA de Gold Level SC825TQ 710LP DP UP 8x SAS SATA 7x LP FL 710W SC825TQ R700UV 4x FF 3x 700W SC825TQ R700UB DEE G SASISATA LP Redundant SC825TQ R700LPV 700W scsz5rQ R700Lpg PP UP 8x SAS SATA 7xLP Redundant SC825TQ 600LPB DP UP 8x SAS SATA 7xLF 600W 7x LF 3x SC825TQ 563LPB Sca25TQ 5e3up PP UP 8x SAS SATA FF 3 LP 560W 1 UIO SC825TQ 560UV 4x FF 3x SC825TQ 560UB DP UP 8x SAS SATA LP 560W SC825TQ 560LPV Besson DP UP 8x SAS SATA 7xLP 560W Legend UP Single processor DP Dual processor FF Full height full length FH Full height half length LF Low profile full length LP Low profile 1 1 SC825 Chassis Manual 1 3 Chassis Features The SC825 2U high performance chassis includes the following features CPU The SC825 chassis supports a dual core Xeon processor Please refer to the moth erboard specifications pages on our web site for updates on supported processors Hard Drives The SC825 chassis features eigh slots for SAS SATA drives These drives are hot swappable Once set up correctly these drives can be removed without power ing down the server In addition these drives support SES2 SAS SATA UO Expansion slots Each SC825 chassis model includes seven low profile UO expansion slots Peripheral Drives Each SC825 chassis supports one slim DVD ROM drive included and one slim flopp
24. age C 1 SC825 Chassis Manual C 3 An Important Note to Users All images and layouts shown in this user s guide are based upon the latest PCB Revision available at the time of publishing The card you have received may or may not look exactly the same as the graphics shown in this manual C 4 Introduction to the BPN SAS 825TQ Backplane The BPN SAS 825TQ backplane has been designed to utilize the most up to date technology available providing your system with reliable high quality performance This manual reflects BPN SAS 825TQ Revision 2 0 the most current release avail able at the time of publication Always refer to the Supermicro web site at www su permicro com for the latest updates compatible parts and supported configurations C 2 Appendix C BPN SAS 825TQ Backplane Specifications C 5 Front Connectors and SAS Ports Figure C 1 Front Connectors Front Connectors SAS Ports 1 4 pin power connector JP13 12 SAS Port 40 2 4 pin power connector JP10 13 SAS Port 1 3 CD ROM floppy connector JP18 14 SAS Port 2 4 CD ROM floppy connector JP17 15 SAS Port 3 5 SAS activity LED header JP26 16 SAS Port 4 6 PC connector 2 JP45 17 SAS Port 5 7 PC connector 1 JP44 18 SAS Port 6 8 Sideband connector 2 JP52 19 SAS Port 7 9 Sideband connector 1 JP51 10 MG9072 chip 11 U
25. apter describes the most common components included with your chassis Some components listed may not be included or may not be compatible with your particular chassis model For more information see the installation instructions detailed later in this manual 3 2 Components Chassis The SC825 chassis includes eight hard drive bays Most chassis models come with a DVD ROM Hard drives must be purchased separately For the latest shipping lists visit our Web site at http www supermicro com This chassis supports a 2U backplane three fans and one or two power supplies SC825 models come in silver or black Backplane Each SC825 chassis comes with a 2U backplane Depending on our order you backplane will accept SAS SATA or SCSI For more information regarding compat ible backplanes view the appendices found at the end of this manual In addition visit our Web site for the latest information http www supermicro com Fans The SC825 chassis supports three system fans System fans for SC825 chassis are powered from the motherboard These fans are 2U high and are powered by 3 pin connectors Mounting Rails The SC825 can be placed in a rack for secure storage and use To setup your rack follow the step by step instructions included in this manual 3 1 SC825 Chassis Manual Power Supply Each SC825 chassis model includes a high efficiency power supply rated at 560W single 563W single 600W single 700W redundant
26. at surface and open the chassis cover If you are using a universal input output card make sure it is installed before continuing If you installing low profile add on cards remove the chassis air shroud Secure the card to the chassis using the four screws provided with the chas sis packaging 5 12 Chapter 5 Chassis Setup and Maintenance 5 8 Installing the Air Shroud Figure 5 12 Air Shroud for SC825LP Chassis Air shrouds concentrate airflow to maximize fan efficiency The SC825 chassis air shroud does not require screws to set up Installing the Air Shroud 1 Confirm that your air shroud matches your chassis model Each shroud is labeled SC825LP or SC825U 2 Place air shroud in the chassis The air shroud fits behind the two fans clos est to the power supply Note that if a 16 DIMM 13 68 x 13 motherboard is used it is necessary to use the optional MCP 310 82502 ON air shroud For ordering information visit the Supermicro website at www supermicro com and click on the Where to Buy link 5 13 SC825 Chassis Manual Figure 5 13 Air Shroud in Place in the SC825LP Chassis Checking the Server s Air Flow Checking the Air Flow 1 Make sure there are no objects to obstruct airflow in and out of the server In addition if you are using a front bezel make sure the bezel s filter is replaced periodically 2 Do not operate the server without drives or drive trays in the drive bays Use only re
27. closed M Figure 5 6 Installing the Hard Drive Warning Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers 5 5 SC825 Chassis Manual 5 5 Installing an Optional Floppy or Fixed Hard Drive The SC825 chassis models include two open slots for an optional floppy drive and or hard disk drive s To utilize these slots the dummy drive and the slot cover must be removed Removing the Dummy Drive Floppy Drive or Hard Disk Drive 1 Disconnect the chassis from any power source 2 Press the release tab 3 Push against the back of the dummy drive sliding the dummy drive and slot cover forward out through the front of the chassis 4 Insert the drive into rear of the open slot and connect the wiring O Release Tabs Figure 5 7 Removing the Dummy Drive and Slot Cover 5 6 Chapter 5 Chassis Setup and Maintenance 5 6 DVD ROM Replacement or Installation Most SC825 chassis models include a DVD ROM which is usually pre installed Installing or Replacing a DVD ROM Drive 1 Power down the system and if necessary remove the server from the rack Remove the chassis cover Unplug the drives power and data cables from the motherboard and or back plane If you are adding a new DVD ROM drive Remove the mini bezel grate from the drive bay The bezel can be removed by pulling out the hard drive beneath the DVD ROM drive bay then pulling the mini bezel forward
28. commended server parts 3 Make sure no wires or foreign objects obstruct air flow through the chassis Pull all excess cabling out of the airflow path or use shorter cables The control panel LEDs inform you of system status See Chapter 3 System Interface for details on the LEDs and the control panel buttons Installation Complete In most cases the chassis power supply and fans are pre installed If you need to install fans continue to the Systems Fan section of this chapter Ifthe chassis will be installed into a rack continue to the next chapter for rack installation instructions Chapter 5 Chassis Setup and Maintenance 5 9 System Fans Three heavy duty fans provide cooling for the chassis These fans circulate air through the chassis as a means of lowering the chassis internal temperature Release Tab Figure 5 14 System Fan Replacing a System Fan 1 If necessary open the chassis while the power is running to determine which fan has failed Never run the server for an extended period of time with the chassis open Turn off the power to the system and unplug the system from the outlet Remove the failed fan s power cord from the serverboard Press the fan release tab to lift the failed fan from the chassis and pull it completely from the chassis Place the new fan into the vacant space in the housing while making sure the arrows on the top of the fan indicating air direction point in the same d
29. d or other controller to the backplane SAS hard drive port Cable Name SAS Cable Quantity 1 Part CBL 0116 Alt Name iPass or Small Four Description This cable has one ipass SFF 8087 mini sas connector 36 pins at one end and 4 SAS connectors on one end This cable connects from the Host motherboard or other controller to the backplane SAS hard drive port A 4 Appendix A Chassis Cables Extending Power Cables Although Supermicro chassis are designed to be efficient and cost effective some compatible motherboards have power connectors located in different areas To use these motherboards you may have to extend the power cables to the mother boards To do this use the following chart as a guide Power Cable Extenders Number of Pins Cable Part Length 24 pin CBL 0042 7 9 20 CM 20 pin CBL 0059 7 9 20 CM 8 pin CBL 0062 7 9 20 CM 4 pin CBL 0060 7 9 20 CM Front Panel to the Motherboard The SC825 chassis includes a cable to connect the chassis front panel to the motherboard If your motherboard uses a different connector use the following list to find a compatible cable Front Panel to Motherboard Cable Ribbon Cable FE cable Part 16 pin 16 pin CBL 0049 16 pin 20 pin CBL 0048 20 pin 20 pin CBL 0047 16 pin various CBL 0068 20 pin various CBL 0067 Split cables Use these cable if your motherboard requires se
30. d with the date of purchase is required be fore any warranty service will be rendered You can obtain service by calling your vendor for a Returned Merchandise Authorization RMA number When returning to the manufacturer the RMA number should be prominently displayed on the outside of the shipping carton and mailed prepaid or hand carried Shipping and handling charges will be applied for all orders that must be mailed when service is complete For faster service RMA authorizations may be requested online http www supermicro com support rma Whenever possible repack the chassis in the original Supermicro carton using the original packaging material If these are no longer available be sure to pack the chassis securely using packaging material to surround the chassis so that it does not shift within the carton and become damaged during shipping This warranty only covers normal consumer use and does not cover damages in curred in shipping or from failure due to the alteration misuse abuse or improper maintenance of products During the warranty period contact your distributor first for any product problems 1 4 Chapter 2 Warning Statements for AC Systems Chapter 2 Standardized Warning Statements for AC Systems 2 1 About Standardized Warning Statements The following statements are industry standard warnings provided to warn the user of situations which have the potential for bodily injury Should you have que
31. e openings in the fan assembly s housing Ze baak Amy Tor Zar DEN 7 END AUTRE IPAPER ls UTS NY FETED DIE 3 Tr ODD FE FAN HEC EDDEDAIEDNFEUT FEW EI AENA UVA RE gt XU UT RE THE RNCS FE RE AI VK SEXES 2 16 Chapter 2 Warning Statements for AC Systems E de El i s CHER TS KRISE BECK SER ilg gt ATRAE NOAA WE A E Warnung Die L fter drehen sich u U noch wenn die L fterbaugruppe aus dem Chassis genommen wird Halten Sie Finger Schraubendreher und andere Gegenst nde von den ffnungen des L ftergeh uses entfernt Advertencia Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis Mandtenga los dedos los destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Il est possible que les ventilateurs soient toujours en rotation lorsque vous retirerez le bloc ventilateur du ch ssis Prenez garde ce que doigts tournevis et autres objets soient loign s du logement du bloc ventilateur mms 07 077219 7779 DWNT TIN NAA MND Pon NA 0507 UND man TANI Onn ONW may 2991 MIVAENT NN TVI prin pmn li casa SSagl y a y yall AES AN 5 Ae gai DY al of Sall e cl all Sis y TRAY As y pall AES A ls ll ye lazer clad jo la pue y Zal AZARES AAE xus sue AVE PREEK eeu Aan Erpel IMA FA BES dall LAAR Waarschuwing Het is mogelijk dat de ventilator nog draait ti
32. er 4 System Interface sure that the chassis covers are installed Finally verify that the heatsinks are installed properly This LED will remain flashing or on as long as the overheat condition exists es NIC2 Indicates network activity on GLAN2 when flashing NIC1 Indicates network activity on GLAN1 when flashing HDD Indicates IDE channel activity in the SAS SATA drive SCSI drive and or DVD ROM drive activity when flashing EP PY Power Indicates power is being supplied to the system s power supply units This LED should normally be illuminated when the system is operating 4 3 SC825 Chassis Manual 4 4 Drive Carrier LEDs Your chassis uses SAS SATA or SCSI drives but not both SASISATA Drives Each SAS SATA drive carrier has two LEDs e Green Each Serial ATA drive carrier has a green LED When illuminated this green LED on the front of the SATA drive carrier indicates drive activity A connection to the SATA backplane enables this LED to blink on and off when that particular drive is being accessed e Red The red LED indicates a SAS SATA drive failure If one of the SAS SATA drives fail you should be notified by your system management software SCSI Drives For information on SCSI drives contact Supermicro s Technical Support Department at www supermicro com 4 4 Chapter 5 Chassis Setup and Maintenance Chapter 5 Chassis Setup and Maintenance 5 1 Overview This chapter c
33. exi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Attention Cette unit peut avoir plus d une connexion d alimentation Pour supprimer toute tension et tout courant lectrique de l unit toutes les connexions d alimentation doivent tre d branch es SAN GD n DP ax mmu TPN naa Dy aman 99 pg von v ppo YW INN mno nv v mm APT DN 2 12 Chapter 2 Warning Statements for AC Systems AGUA aal las y Y LA ae ea ld y y A el ll ge as al dal ONLY AUS ATI 5 casa 7 51 e HAE RA IA AA FE HAT AAs MS UE ol HA ol AAL AU WIS LE AA HAE AA So quu Waarschuwing Deze eenheid kan meer dan n stroomtoevoeraansluiting bevatten Alle aansluitingen dienen verwijderd te worden om het apparaat stroomloos te maken Backplane Voltage A Warning Hazardous voltage or energy is present on the backplane when the system is operating Use caution when servicing NIFV DEE DAT LORDS EGE EE TALI DN ITU LIC DO TET ART S RIE EL HRAT RARE gt DEPTH FW VG r1 LITA LAER ERE HET SRE e Warnung Wenn das System in Betrieb ist treten auf der R ckwandplatine gef hrliche Spannungen oder Energien auf Vorsicht bei der Wartung iAdvertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga c
34. hat the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them e In single rack installation stabilizers should be attached to the rack e n multiple rack installations the racks should be coupled together Always make sure the rack is stable before extending a component from the rack You should extend only one component at a time extending two or more si multaneously may cause the rack to become unstable General Server Precautions Review the electrical and general safety precautions that came with the com ponents you are adding to your chassis Determine the placement of each component in the rack before you install the rails e Install the heaviest server components on the bottom of the rack first and then work up Use a regulating uninterruptible power supply UPS to protect the server from power surges voltage spikes and to keep your system operating in case of a power failure Allow the hot plug hard drives and power supply modules to cool before touch ing them Always keep the rack s front door and all panels and components on the servers closed when not servicing to maintain proper cooling Chapter 6 Rack Installation Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi unit rack assembly the ambient operating tempera ture of the rack environment may be greater than the ambient
35. hren kann Machen Sie sich vor der Arbeit mit Ger ten mit den Gefahren elektrischer Schaltungen und den blichen Verfahren zur Vorbeugung vor Unf llen vertraut Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen bersetzung in den bersetzten Sicherheitshinweisen die zusammen mit diesem Ger t ausgeliefert wurden BEWAHREN SIE DIESE HINWEISE GUT AUF INSTRUCCIONES IMPORTANTES DE SEGURIDAD Este simbolo de aviso indica peligro Existe riesgo para su integridad fisica Antes de manipular cualquier equipo considere los riesgos de la corriente el ctrica y familiaricese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar el texto traducido en el apartado de traducciones que acompa a a este dispositivo GUARDE ESTAS INSTRUCCIONES IMPORTANTES INFORMATIONS DE S CURIT Ce symbole d avertissement indique un danger Vous vous trouvez dans une situation pouvant entra ner des blessures ou des dommages corporels Avant de travailler sur un quipement soyez conscient des dangers li s aux circuits lectriques et familiarisez vous avec les proc dures couramment utilis es pour viter les accidents Pour prendre connaissance des traductions des avertissements figurant dans les consignes de s curit traduites qui accompagnent cet appareil r f rez vous au num ro de l instruction situ la fin de chaque avertis
36. icro seulement AC RnD o gt awn gums WN AC PARNA D PDD 0 222 VANWA W INA NN D PPNA WR IN pn 01149 DID INN ONNA IN 525 992 vio gt AVD 129107 1791 TION DP mmo pim Yawn 0922 sg PIN D YY san xp bp mp DY FPD 3805 CSA 2 IN UL 2 550157 005252 vinum 3292 PPD vm YY mms NAW INN YAWN II 99 1129 UL CSA Asi 4g SIE SAS ge Jm gill AS ell casa gal Cus yi sie aa Gell Jul CN gas y Gaya A dhe Di gas ve casus 5 Y gaa y A csi ali of uil cela ee UL j CSA SUSI aal ls dada cy gild al za y AG Sll 5 es Y J ya Barcia Supermicro J ya Aia ill j 5 al Ai w 5 sl T UL CSA Aale Jami A 78 11 AES AAE uou SAY AAA ADA IEA AAA ACA HEE ALBA BUCH 2 WE CHE gol HE OIL HES A EE sie ade a VE 112 FA Electrical Appliance and Material Safety Law 2 4013949 JAH ASS AE 1949 HE A7 FAES 8 ULI CSAIA AGA AMECA Ho UL CSA7E EA SA ARES emu ul de Waarschuwing Bij het installeren van het product gebruik de meegeleverde of aangewezen kabels stroomkabels en adapters Het gebruik van andere kabels en adapters kan leiden tot een storing of een brand Elektrisch apparaat en veiligheidsinformatiebladen wet verbiedt het gebruik van UL of CSA gecertificeerde kabels die UL of CSA die op de code voor andere elektrische apparaten dan de producten die door Supermicro alleen 2 19 xxx Chassis User s Manual Notes 2 20 Chapter 3 Chassis Components Chapter 3 Chassis Components 3 1 Overview This ch
37. ion contre les courts circuits surtension ce produit d pend de l installation lectrique du local V rifiez que le courant nominal du dispositif de protection n est pas sup rieur 250 V 20 A 5 xm v UN p NIN 071292 NIN mun Yy TND AT 3372 250 V 20 A 15 IP R NIT YAWN EPT 352 1150 TWIN Leift d Ai B w ll Nl Cu Adan lame le dins all D 2 20A 250V ie S oel EN Ll andi Ci ge ast 2 5 xxx Chassis User s Manual AX oale daa HA A el dad dao de wa ule JES gx BA REEN 250V Gx E 20A Ho S SEA EE ot hu Waarschuwing Dit product is afhankelijk van de kortsluitbeveiliging overspanning van uw electrische installatie Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan 220V 20A Power Disconnection Warning A Warning The system must be disconnected from all sources of power and the power cord removed from the power supply module s before accessing the chassis interior to install or remove system components EMUO RS ZAT ANR ZY POMO NETO ALO RDA Vy Y ICI A FAA ZAT LO BES SN TOY ARDEN el Fi a DID NT BRMBOET me FATE EAS ER DURER SE RTE JETER ARE At ESL ERAS RATA DAR ARTE REMER Warnung Das System muss von allen Quellen der Energie und vom Netzanschlusskabel getrennt sein das von den Spg Versorgungsteilmodulen entfernt wird bevor es auf den Chassisinnenraum zur ckgreift
38. irec tion as the arrows on the other fans Power up the system and check that the fan is working properly before re placing the chassis cover 5 15 SC825 Chassis Manual Figure 5 15 Placing the System Fan 5 16 Chapter 5 Chassis Setup and Maintenance 5 10 Power Supply Depending on your chassis model the SC825 Chassis has a 560 600 700 710 720 or 740 Watt power supply This power supply is auto switching capable This enables it to automatically sense and operate at a 100v to 240v input voltage An amber light will be illuminated on the power supply when the power is off An il luminated green light indicates that the power supply is operating Power Supply Failure SC825 chassis models have either one or two redundant power supplies In the unlikely event that the power supply unit fails if you have a single power supply the system will shut down and you will need to replace the power supply unit SC825 chassis models which include a redundant power supply will allow for the power supply to be replaced without powering down the system Replacement units can be ordered directly from Supermicro see the contact infor mation in the Preface 5 17 SC825 Chassis Manual Release Tab Figure 5 16 Removing the Power Supply Replacing the Power Supply 1 If your chassis includes a redundant power supply at least two power mod ules you can leave the server running and remove only one power
39. jdens het verwijderen van het ventilatorsamenstel uit het chassis Houd uw vingers schroevendraaiers en eventuele andere voorwerpen uit de buurt van de openingen in de ventilatorbehuizing 2 17 xxx Chassis User s Manual Power Cable and AC Adapter A Warning When installing the product use the provided or designated connection cables power cables and AC adaptors Using any other cables and adaptors could cause a malfunction or a fire Electrical Appliance and Material Safety Law prohibits the use of UL or CSA certified cables that have UL CSA shown on the code for any other electrical devices than products designated by Supermicro only WPI REACT A7 A BEDELS SAA URETA EA TARRO TV FER REACT 27 A ZIEH P amp O DT 7 6o7y 27 ARENT ALNA KORNER TEDD DES EUH ERA ULE 7 IRAN D7 7 JW UL CSEv 775a FICK oU Supermicro fH FS ADU MEETS STERIEL TOES ZERE aft TS GEH AS Er pe DE SUR EB ERE BA EEN de GEM HT HE de ol BESS EURO gt ERY Supe rmi c roffa EAI de BSH All TEE ELIE TS IE BE FHZRZEULERCSATA ERIBA gt RM ES RUL CSARFS EX A zi H x A E SEAS IL aE d EA EAT vn ERE E 77 SC REO EEE Ek SE gt ER T Supe rmi cropa EN Ein BIA nf TERES ESUESEIEREFHZRAEULSKCSASESGBJARRI gt SUN Leger CAE be DL Hr EF D f y
40. n 4 1 4 2 Control Panel Buttons san cerco rper rate 4 2 4 3 Control Panel LEDS sne iaa a i ri ne tr enti nae 4 2 44 Drive CamerbEDS cto eret eoa riesen 4 4 TO santen seer eea ve edad 4 4 E SI SS ena casa cape a a ae ee cece teense E 4 4 Chapter 5 Chassis Setup and Maintenance 5 1 EE 5 1 5 2 Installation and General Maintnenance nnen 5 1 A ay us ern 5 1 5 3 Removing the Chassis Cover 5 2 5 4 installing Hard Ee enia en eret o ce eet 5 3 5 5 Installing an Optional Floppy or Fixed Hard Drive 5 6 5 6 DVD ROM Replacement or Installation nnen erneer enennnenreneneneenn 5 7 Replacing the DVD ROM and Front Panel ennen eenenenren 5 7 5 7 installing the Motherboard iere nassen 5 8 VO Shield meer 5 8 Installing the VO Shield eo na 5 8 Permanent and Optional Standoffs cnn 5 9 Add on Card Expansion Slot Setup 5 11 Add on Card Expansion Slot Setup in LP Low Profile Chassis 5 11 Add on Card Expansion Slot Setup for SC825U Universal Output 5 12 5 8 Installing the Air Shroud cnn nana ncnnnnne 5 13 Checking thie Server s Alr FIOW ociosas re rete eii ee creta eaa 5 14 Installation Complete 9 Sege een 5 14 e WEE NIE 5 15 5 10 POWE SUPPI srta nostro 5 17 Power Supply Fail 12 irri eee senen even eenen enden 5 17 Replacing the Power Distributor A 5 19 Replacing or Installing the Front Port Panel 5 20 5 11 Optional
41. n of Jumpers om ud Connector To modify the operation of the backplane rue DEE Open jumper off jumpers can be used to choose between L the pins optional settings Jumpers create shorts between two pins to change the function Jumper of the connector Pin 1 is identified with opns EH en a square solder pad on the printed circuit n board Note On two pin jumpers Closed Setting means the jumper is on and Open means ENE the jumper is off the pins Jumper Settings Jumper Jumper Settings Note JP29 Open Jumper off the pins Default MG9072 chip reset Closed Jumper on the pins Reset JP18 Open Jumper off the pins Default Buzzer reset Closed Jumper on the pins Reset The buzzer sound indicates that a condition requiring immediate attention has occurred The buzzer alarm is triggered by the following conditions 1 Hard drive failure 2 System temperature over 45 Celsius C 6 Appendix C BPN SAS 825TQ Backplane Specifications SGPIO and PC Modes and Jumper Settings This backplane can utilize SGPIO or I C which is the default mode and can be used without making changes to your jumpers The following information describes which jumper must be configured to use SGPIO mode SGPIO Settings Jumper JP33 JP34 JP36 JP37 JP38 JP40 JP41 JP42 JP43 JP50 Jumper Setting 1 2 1 2 1 2 1 2 Open Jumper off the pins Closed Jumper on the pi
42. ns Closed Jumper on the pins 1 2 1 2 Open Jumper off the pins C 7 Notes Controller ID 1 Backplane ID 1 1 2 IDZO Controller ID 2 Backplane ID 2 1 2 ID 0 PC Reset 2 PC Reset_SDOUT 1 PC Reset_SDOUT 2 DC Backplane ID_SDIN 1 PC Backplane ID_SDIN 2 PC Reset 1 SC825 Chassis Manual PC Settings Default Jumper JP33 JP34 JP36 JP37 JP38 JP40 JP41 JP42 JP43 JP50 Jumper Setting 2 3 1 2 2 3 2 3 Closed Jumper on the pins Open Jumper off the pins Open Jumper off the pins 2 3 2 3 Closed Jumper on the pins C 8 Notes Controller ID 1 Backplane ID 1 1 2 ID 0 2 3 ID 1 Controller ID 2 Backplane ID 2 1 2 ID 0 2 3 ID 1 PC Reset 2 PC Reset_SDOUT 1 PC Reset_SDOUT 2 PC Backplane ID_SDIN 1 12C Backplane ID_SDIN 2 PC Reset 1 Appendix C BPN SAS 825TQ Backplane Specifications SAS Port Connections in lC and SGPIO Settings Use the following chart when connecting this backplane If the SAS ports are con nected out of order it is not easy to identify drives using the LED function SAS Port Connections in C and SGPIO Settings Port PC SGPIO 0 3 PC 1 Sideband 1 4 7 PC 2 Sideband 2 Front LED Indicators NI OB b g HH Figure C 4 Front LED Front Panel LEDs
43. ou want to use Keep this screw for later use 3 Connect the add on cards and or expansion cards to the mother board 4 Secure each card to the chassis using the card s L bracket and the screw previously removed 5 11 SC825 Chassis Manual Add on Card Expansion Slot Setup for SC825U Universal Output SC825U chassis accepts a slightly smaller L shaped motherboard to allow for a universal expansion card This universal output card allows the systems to accept SAS SCSI IB Ethernet and other types of connections SC825U chassis are setup similar to 825RC chassis with two differences A The SC825U chassis accepts three full length full height add on cards instead of four The fourth slot is used for the UI O card B The SC825U chassis includes a bracket that extends from the fan row to the back of the chassis This bracket provides support for the riser card Installing a Universal Input Output Card in the SC825U chassis 1 Disconnect the power supply lay the chassis on a flat surface and open the chassis cover Connect the universal input output to the motherboard using the slots pro vided on the motherboard and the back panel Secure the card to the chassis using the four screws provided with the chas sis packaging The SC825U chassis accepts 3 full height full length slots and 3 low profile slots Installing Add on Cards in the SC825U Chassis 1 Disconnect the power supply lay the chassis on a fl
44. over in place The chassis cover must be in place to allow proper airflow and prevent overheating 5 2 Chapter 5 Chassis Setup and Maintenance 5 4 Installing Hard Drives Figure 5 2 Removing Hard Drive Removing Hard Drive Trays from the Chassis 1 Press the release button on the drive carrier This extends the drive carrier handle 2 Use the handle to pull the drive out of the chassis SC825 Chassis Manual Drive Carrier Figure 5 3 Chassis Drive Carrier The drives are mounted in drive carriers to simplify their installation and removal from the chassis These carriers also help promote proper airflow for the drive bays Figure 5 4 Removing Dummy Drive from Carrier Installing a Hard Drive to the Hard Drive Carrier 1 Remove the screws securing the dummy drive to the carrier 2 Remove the dummy drive from the carrier Warning Except for short periods of time swapping hard drives do not operate the server with the hard drives removed from the bays 5 4 Chapter 5 Chassis Setup and Maintenance SAS SATA Hard Drive Carrier Figure 5 5 Removing the Hard Drive 3 Install a new drive into the carrier with the printed circuit board side facing down so that the mounting holes align with those in the carrier 4 Secure the hard drive by tightening all six screws 5 Replace the drive carrier into the chassis bay making sure that the drive car rier handle is completely
45. overs the steps required to install components and perform mainte nance on the chassis The only tool you will need to install components and perform maintenance is a Phillips screwdriver Print this page to use as a reference while setting up your chassis 5 2 Installation and General Maintnenance Installation e Removing the Chassis Cover Installing Hard Drives Installing an Optional Floppy Drive or Fixed Hard Drive DVD ROM Replacement or Installation e Installing the Motherboard includes I O Slot Setup e Installing the Air Shroud General Maintenance System Fans Replacing the Power Supply Optional Front Bezel Review the warnings and precautions listed in the manual before setting up or servicing this chassis These include information in Chapter 2 System Safety and the warning precautions listed in the setup instructions 5 1 SC825 Chassis Manual 5 3 Removing the Chassis Cover Remove Screw Release Tab Figure 5 1 Removing the Chassis Cover Removing the Chassis Cover 1 Remove the two screws on each side of the cover which secure the cover to the chassis 2 Press the release tabs to remove the cover from the locked position Press both tabs at the same time 3 Once the top cover is released from the locked position slide the cover toward the rear of the chassis 4 Lift the cover off the chassis Warning Except for short periods of time do NOT operate the server without the c
46. pgrade header JP46 Figure C 2 Front SAS Ports C 3 SC825 Chassis Manual C 6 Front Connector and Pin Definitions 1 and 2 Backplane Main Power Connec tors The 4 pin connectors designated JP10 and JP13 provide power to the backplane See the table on the right for pin definitions 3 and 4 CD ROM Floppy Pin Connectors Pin connectors designated J17 and J18 provide power to the CD ROM and floppy drives See the table on the right for pin definitions 5 Activity LED Headers The activity LED header designated JP26 is used to indicate the activity status of each SAS drive The activity LED header is located on the front panel For the activity lead header to work properly connect to it using a 10 pin LED cable This is only used when the activity LED is not supported by the hard drive 6 and 7 lC Connectors The PC Connectors designated JP44 and JP45 are used to monitor the HDD activity and status See the table on the right for pin definitions C 4 Backplane Main Power 4 Pin Connector Pin Definition 1 12V 2 and 3 Ground 4 5V CD ROM FDD Power 4 Pin Connector Pin Definition 1 5V 2 and 3 Ground 4 12V SAS Activity LED Header Pin Definitions Pin a BB N Definition Pin Definition ACT INFO 6 ACT IN 4 ACT IN 1
47. rmore buyer agrees to fully indemnify defend and hold Supermicro harmless for and against any and all claims demands actions litigation and proceedings of any kind arising out of or related to such ultra hazardous use or sale
48. sement CONSERVEZ CES INFORMATIONS mmus nns mpn moan 155 wanwan NN vum nio YY WYND 320 D by nma IF DINAN nmn n nn Dap oy Wp mx v 9093 79922 012207 IN NRW v TTPA NWR MPD pasan DN IIT IN PPNT PRVI 7252 22015 DNI 192010 DW n 190 Tip i530 TINA 0222299 nan IN NIPAT 2199 181522 NOOI NN NP v 2 2 Warning Statements for AC Systems ha Aal am Ol E Alla el Ya ja ll Dal is Sil gall ge Anal Ll le de Silao gl le Jess gf Ja A sll leien Ayala JS Ailes ya paill ll exsul AE FA i ro p fijo BELANGRIJKE VEILIGHEIDSINSTRUCTIES Dit waarschuwings symbool betekent gevaar U verkeert in een situatie die lichamelijk letsel kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan het eind van elke waarschuwing om deze te herleiden naar de desbetreffende locatie BEWAAR DEZE INSTRUCTIES 2 3 xxx Chassis User s Manual Installation Instructions A Warning Read the installation instructions before connecting the system to the power source eue TS VAT LATIN CAS SiC an T E ma FEN PHAR ERE AIA ce gt Hi A ES CT ht CEA EE ERAT GTC 2 Warnung Vor dem Anschlie en des Systems an die Stromquelle die Installationsanweisungen lesen jAdvertencia Lea las instrucciones de
49. sing the screws provided Press the button where the two outer rails are joined to retract the smaller outer rail Hang the hooks of the rails onto the rack holes and if desired use screws to secure the front of the outer rail onto the rack Repeat steps 1 3 for the remaining outer rail 6 6 Chapter 6 Rack Installation Figure 6 4 Installing the Chassis into the Rack Note figures are for illustrative purposes only Always install servers into racks from the bottom up Installing the Chassis into a Rack 1 Extend the outer rails as illustrated above 2 Align the inner rails of the chassis with the outer rails on the rack 3 Slide the inner rails into the outer rails keeping the pressure even on both sides When the chassis has been pushed completely into the rack it should click into the locked position 4 Optional screws may be used to secure the to hold the front of the chassis to the rack 6 7 SC825 Chassis Manual Notes 6 8 Appendix B Power Supply Specifications Appendix B SC825 Power Supply Specifications This appendix lists power supply specifications for your chassis system SC825 Series MFR Part Rated AC Voltage AC Input DC Input Voltage DC Output 5V standby 12V 5V 3 3V 12V 560W PWS 561 1H20 100 240V 50 60Hz 8 5 4 Amp 600W PWS 605P 1H 7 5 Amp max 3 Amp 49 Amp 18 Amp 15 Amp 0 5 B 1 100 240 V 50 60 Hz
50. stions or experience difficulty contact Supermicro s Technical Support department for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis These warnings may also be found on our web site at http www supermicro com about policies safety_information cfm Warning Definition A Warning This warning symbol means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents BEDEK BEA AER LES NEELIE RIED BO 370 C d TUO MER C GB LS AIC SACA EEE C BREN EDS RIOT FEU TS Ce EEM FREZEN ER D EE EREN B LE Z BE DAT SUUS E AER DELIFER ARE RIT EE FANS EREE Ue HEE ELA e HEEE gt AE RE SAE TT AE IR LIFE gt TERA Ea ZA ER FRAY abe gt PATS ADT AEE AE gt AR ESR HERE AGA HAA ZS gt I en xxx Chassis User s Manual Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr Sie befinden sich in einer Situation die zu Verletzungen f
51. supply If your server has only one power supply you must power down the server and unplug the power cord before replacing the power supply 2 Push the release tab on the back of the power supply as illustrated 3 Pull the power supply out using the handle provided 4 Replace the failed power module with the same model 5 Push the new power supply module into the power bay until you hear a click 6 Plug the AC power cord back into the module and power up the server Chapter 5 Chassis Setup and Maintenance N EN d d Pe WS Ney UY SS AN Figure 5 17 Replacing the Power Distributor Replacing the Power Distributor Redundant server chassis that are 2U or greater require a power distributor The power distributor provides failover and power supply redundancy In the unlikely event you must replace the power distributor do following 1 Power down the server and remove the plug from the wall socket or power strip 2 Remove all cable connections to the power supply from the motherboard backplane and other components Also remove both power supplies 3 Locate the power distributor between the power supply and the fan row 4 Remove the three screws securing the power supply 5 Gently pull the power distributor from the chassis Gently guide all the cables through the power distributor housing 6 Slide the new power distributor module into the power distributor housing Make
52. that you slide the cables through the bottom of the housing 7 Reconnect all the power cables replace the power supply and insert the plug into the wall 5 19 SC825 Chassis Manual Replacing or Installing the Front Port Panel Replace or Install the Front Port Panel 1 Power down and unplug the system 2 Remove the chassis cover 3 Disconnect the power and data cables from the front port panel to other chassis components including the motherboard and backplane 4 Remove the old port panel by depressing the release tab then pulling the unit out of the chassis 5 Insert the new front port panel unit in the slot until the tab locks into place 6 Connect the data and power cables to the backplane and motherboard For more information see the manual for your backplane in the appendix 5 20 Chapter 5 Chassis Setup and Maintenance 5 11 Optional Front Bezel The SC825 chassis supports an optional full face locking front bezel for added se curity The front bezel is not included with the SC825 chassis but can be ordered seperately by visiting the Supermicro Web site at www supermicro com clicking on the Where to Buy link and referencing part number MCP 210 82503 0B 5 21 SC825 Chassis Manual Notes 5 22 Chapter 6 Rack Installation Chapter 6 Rack Installation 6 1 Overview This chapter provides a quick setup checklist to get your chassis up and running Following these steps in the order gi
53. the bottom to the top with the heaviest component at the bottom of the rack e f the rack is provided with stabilizing devices install the stabilizers before mounting or servicing the unit in the rack 6 3 SC825 Chassis Manual 6 4 Rack Mounting Instructions This section provides information on installing the SC825 chassis into a rack unit with the quick release rails provided There are a variety of rack units on the market which may mean the assembly procedure will differ slightly You should also refer to the installation instructions that came with the rack unit you are using NOTE This rail will fit a rack between 26 and 33 5 deep Separating the Sections of the Rack Rails The chassis package includes two rail assemblies in the rack mounting kit Each assembly consists of two sections an inner fixed chassis rail that secures directly to the server chassis and an outer fixed rack rail that secures directly to the rack itself D Rail Assembly Separating the Inner and Outer Rails 1 Locate the rail assembly in the chassis packaging Extending the Rails 2 Extend the rail assembly by pulling it outward 3 Press the quick release tab Quick 4 Separate the inner rail extension from Release Tab the outer rail assembly 4 Separating the Inner Rail Extension Figure 6 1 Separating the Rack Rails Warning do not pick up the server by the front handles They are designed to pull the system from a rack onl
54. uidado cuando lo revise Attention Lorsque le systeme est en fonctionnement des tensions lectriques circulent sur le fond de panier Prendre des pr cautions lors de la maintenance 2 13 xxx Chassis User s Manual nen 5353 nnn rms Jona Ann v n y5n 91990 para AND 2192 nn n150 nip max da UI cle Basa sell ABUSE si je LA Gye jha lua Ja la da Ae yaa CS Jan alaill y 9 aie 73 1 NARO 52 el d FER Backplane A AAF AH dl lt way Bd AMA 4 A FSA Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het Systeem in gebruik is Voorzichtigheid is geboden tijdens het onderhoud Comply with Local and National Electrical Codes Warning Installation of the equipment must comply with local and national electrical codes HIT KID ABU PERO EU CE DHS UMD EEN ab EL B ZED EAS A FRI TH e BEL A EL UREA O AAA RA gt Warnung Die Installation der Ger te muss den Sicherheitsstandards entsprechen Advertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales Chapter 2 Warning Statements for AC Systems Attention L quipement doit tre install conform ment aux normes lectriques nationales et locales zin YAWN pin DNN gums JOP SINT Dapp YAWN pn noxii ng nan TPE npn daleiall Ail gll y ll al all Jar Of cas Aio w ll Glaeall Gus Y sb je Sls 7 51 23449 2 sre
55. um Systemsbestandteile anzubringen oder zu entfernen 2 6 Chapter 2 Warning Statements for AC Systems Advertencia El sistema debe ser disconnected de todas las fuentes de energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le systeme doit tre d branch de toutes les sources de puissance ainsi que de son cordon d alimentation secteur avant d acc der l int rieur du chassis pour installer ou enlever des composants de syst me wad paona san 525 nx Pon Uu Dawn nmpn 927 0997 NN pI v 022231 0305 AN Pop TNE msn dw man pon nu 10 Yael bas y yo oly w ll Al AN 5 y ABN jalo aa pe pill ued Gas J AULII les ca Sa AN gf cuil JS Gia Lil U ssa d AAW PSs Wap sp see use dcs en A 5 WEA AA DIAZ AAA FE AAW EE Bellot Waarschuwing Voordat u toegang neemt tot het binnenwerk van de behuizing voor het installeren of verwijderen van systeem onderdelen dient u alle spanningsbronnen en alle stroomkabels aangesloten op de voeding en van de behuizing te verwijderen 2 7 xxx Chassis User s Manual Equipment Installation A Warning Only trained and qualified personnel should be allowed to install replace or service this equipment PO ix irt PLATERO BEEN TENEU NT ORO Hit SER Fiel EA ANTUOKT AREA ERFAHREN DT
56. ve harm Manual Revision 2 0 Release Date June 13 2013 Unless you request and receive written permission from Super Micro Computer Inc you may not copy any part of this document Information in this document is subject to change without notice Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders Copyright O 2013 by Super Micro Computer Inc All rights reserved Printed in the United States of America Preface Preface About This Manual This manual is written for professional system integrators and PC technicians It provides information for the installation and use of the SC825 2U chassis Installa tion and maintenance should be performed by experienced technicians only Supermicro s SC825 2U chassis features a unique and highly optimized design The chassis is equipped with a 560W single 563W single 600W single 700W redundant 710W single 720W redundant or 740W redundant high efficiency power supply for superb power savings High performance fans provide ample optimized cooling for the chassis This document lists compatible parts and configurations available when this docu ment was published Always refer to the our Web site for updates on supported parts and configurations SC825 Chassis Manual Manual Organization Chapter 1 Introduction The first chapter provides a checklist of the main components included
57. ven should enable you to have the system operational within a minimum amount of time 6 2 Unpacking the System You should inspect the box the chassis was shipped in and note if it was damaged in any way If the chassis itself shows damage you should file a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold your chassis lt should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated You will also need it placed near a grounded power outlet Be sure to read the Rack and Server Pre cautions in the next section 6 3 Preparing for Setup The box your chassis was shipped in should include two sets of rail assemblies two rail mounting brackets and the mounting screws you will need to install the system into the rack Please read this section in its entirety before you begin the installation procedure outlined in the sections that follow Choosing a Setup Location e Leave enough clearance in front of the rack to enable you to open the front door completely 25 inches e Leave approximately 30 inches of clearance in the back of the rack to allow for sufficient airflow and ease in servicing e This product is for installation only in a Restricted Access Location dedicated equipment rooms service closets and the like 6 1 SC825 Chassis Manual Rack Precautions e Ensure t
58. veral different con nections from the front panel A 5 SC825 Chassis Manual Notes A 6 Appendix C BPN SAS 825TQ Backplane Specifications Appendix C BPN SAS 825TQ Backplane Specifications To avoid personal injury and property damage carefully follow all the safety steps listed below when accessing your system or handling the components C 1 ESD Safety Guidelines Electrostatic Discharge ESD can damage electronic components To prevent dam age to your system it is important to handle it very carefully The following measures are generally sufficient to protect your equipment from ESD Use a grounded wrist strap designed to prevent static discharge Touch a grounded metal object before removing a component from the antistatic bag Handle the backplane by its edges only do not touch its components peripheral chips memory modules or gold contacts When handling chips or modules avoid touching their pins Put the card and peripherals back into their antistatic bags when not in use General Safety Guidelines Always disconnect power cables before installing or removing any components from the computer including the BPN SAS 825TQ backplane Disconnect the power cable before installing or removing any cables from the BPN SAS 825TQ backplane Make sure that the BPN SAS 825TQ backplane is securely and properly in stalled on the motherboard to prevent damage to the system due to power short
59. with this chassis and describes the main features of the SC825 chassis This chapter also includes contact information Chapter 2 System Safety This chapter lists warnings precautions and system safety You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed before installing and servicing this chassis Chapter 3 Chassis Components Refer here for details on this chassis model including the fans bays airflow shields and other components Chapter 4 System Interface Refer to this chapter for details on the system interface which includes the functions and information provided by the control panel on the chassis as well as other LEDs located throughout the system Chapter 5 Chassis Setup and Maintenance Refer to this chapter for detailed information on this chassis You should follow the procedures given in this chapter when installing removing or reconfiguring your chassis Chapter 6 Rack Installation Refer to this chapter for detailed information on chassis rack installation You should follow the procedures given in this chapter when installing removing or reconfiguring your chassis into a rack environment Preface Appendices This section lists compatible cables power supply specifications and compatible backplanes Not all compatible backplanes may be listed Refer to our Web site for the latest compatible backplane information SC825
60. y 6 4 Chapter 6 Rack Installation e Figure 6 2 Installing the Inner Rail Extensions Installing the Inner Rail Extension The SC825 chassis includes a set of inner rails in two sections inner rails and inner rail extensions The inner rails are pre attached to the chassis and do not interfere with normal use of the chassis if you decide not to use a server rack The inner rail extension is attached to the inner rail to mount the chassis in the rack Installing the Inner Rails 1 Place the inner rail extensions on the side of the chassis aligning the hooks of the chassis with the rail extension holes Make sure the extension faces outward just like the pre attached inner rail 2 Slide the extension toward the front of the chassis 3 Optional Secure the chassis with 2 screws as illustrated Repeat steps for the other inner rail extension Stability hazard The rack stabilizing mechanism must be in place or the rack must be bolted to the floor before you slide the unit out for servicing Failure to stabilize the rack can cause the rack to tip over 6 5 SC825 Chassis Manual A K eS N Figure 6 3 Assembling the Outer Rails Outer Rack Rails Outer rails attach to the rack and hold the chassis in place The outer rails for the SC825 chassis extend between 30 inches and 33 inches Installing the Outer Rails to the Rack 1 Secure the back end of the outer rail to the rack u
61. y drive optional These drives allow you to quickly install or save data Other Features Other onboard features are included to promote system health These include various three cooling fans a convenient power switch reset button and five LED indicators SCSI Chassis Models For information on SCSI chassis models contact Supermicro s Technical Support department at www supermicro com 1 2 Chapter 1 Introduction Contacting Supermicro Headquarters Address Tel Fax Email Web Site Europe Address Tel Fax Email Asia Pacific Address Tel Fax Web Site Super Micro Computer Inc 980 Rock Ave San Jose CA 95131 U S A 1 408 503 8000 1 408 503 8008 marketing supermicro com General Information support supermicro com Technical Support www supermicro com Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands 31 0 73 6400390 31 0 73 6416525 sales supermicro nl General Information support supermicro nl Technical Support rma gsupermicro nl Customer Support Super Micro Computer Inc 4F No 232 1 Liancheng Rd Chung Ho 235 Taipei County Taiwan R O C 886 2 8226 5990 886 2 8226 3991 www supermicro com tw Technical Support Email Tel support supermicro com tw 886 2 8226 5990 1 3 SC825 Chassis Manual 1 5 Returning Merchandise for Service A receipt or copy of your invoice marke

Download Pdf Manuals

image

Related Search

Related Contents

Manual de usuario convertidor MDB a Pulsos V1.0  Manual de instrucciones y de montaje Intercomunicador    Samsung Багатофункціональний пристрій SCX-5330N Керівництво користувача  en user instructions and safety - N  Quick Start Guide  Software reference guide  Polaroid PhotoMax MP3 Digital Camera  PDFファイル  