1. OST Omnitron Systems Technology Inc iConverter 1 Module Power Chassis User Manual 140 Technology Dr Irvine CA 92618 USA Phone 949 250 6510 Fax 949 250 6514 Warning The operating description in this Instruction Manual is for use by qualified personnel only To avoid electrical shock do not perform any servicing of this module other than that contained in the operating instructions unless you are qualified and certified to do so by Omnitron Systems Technology Inc Caution All user required operations can be performed without opening the chassis Never attempt to open or remove the cover or tamper with the chassis There are no user replaceable or serviceable parts in this unit Equipment is not intended to be installed and used in a place home school or public area accessible to the general population Warranty This product is warranted to the original purchaser against defects in material and workmanship for a period of TWO YEARS from the date of shipment A LIFETIME warranty may be obtained by the original purchaser by REGISTERING this product with Omnitron within 90 days from the date of shipment TO REGISTER COMPLETE AND MAIL OR FAX THE ENCLOSED REGISTRATION FORM Or you may register your product on the Internet at http Awww omnitron systems com During the warranty period Omnitron will at its option repair or replace a product which is proven to be defective For warranty service the product mu
2. the module by fastening the front panel thumbscrew push in and turn clockwise to tighten to the chassis front 2 2 AC Powered Chassis To power the unit using the AC DC adapter connect the AC DC adapter to the AC outlet Then connect the barrel plug at the end of the wire on the AC DC adapter to the DC barrel connector center positive on the unit Route the power cable through the provided strain relief for additional support Confirm that the unit has powered up properly by checking the Power LED located on the front of the installed module Use only the supplied AC DC power adapter to power the chassis NOTE The 8242 x and 8243 x models use a different AD DC power adapter than the 8240 x and 8241 x models The DC barrel connector on the 8242 x and 8243 x is a 2 1mm center connector and supplies a nominal 48VDC The DC barrel connector on the 8240 x and 8241 x is a 2 5mm center connector and supplies a nominal 9VDC If installing with the NEBS Mounting Kit for 8242 x and 8243 x models secure the grounding wire to the ground lug See Figure 2 for the location of the grounding lug NEBS Grounding Strain Relief Barrel Connector Fig 2 Rear of 1 Module Power Chassis Models 8242 x and 8243 x with AC Power Connector Page 4 2 3 DC Powered Chassis Site Preparation Power source should be available within 5 ft of the chassis The over current protection for connection with centralized DC shall be provided in the building insta
3. 4 140 Technology Dr 500 Irvine CA 92618 USA Email URL www omnitron systems com Omnitron Systems Technology Inc support omnitron systems com Page 7 040 08240 0011 09 12
4. Models 8242 9 and 8243 9 with DC Power Connector DC Connector WARNING NEVER ATTEMPT TO OPEN THE CHASSIS OR SERVICE THE POWER SUPPLY OPENING THE CHASSIS MAY CAUSE SERIOUS INJURY OR DEATH THERE ARE NO USER REPLACEABLE OR SERVICEABLE PARTS IN THIS UNIT Page 6 3 0 SPECIFICATIONS Model Number 8240 1 8240 2 8242 1 8242 2 I 8242 9 8241 1 8241 2 8243 1 8243 2 8243 9 Module Capacity 1 Power Supply Type Wall Power Tabletop Tabletop Power Tabletop User Supplied Supply Power Supply Supply Power Supply Power Supply US Plug IEC 320 US Power Cord IEC 320 3 Position Connector Socket Socket Terminal Power Requirements 120VAC 60Hz 100 to 240VAC 120VAC 60Hz 100 to 240VAC 20 to 60VDC 50 60Hz 50 60Hz 0 2A 1 0A Q 0 6A Max 120VAC 0 2A 120VAC 1 0A Q 120VAC 120VAC Dimensions W 38 xP 55X Els 10 W 3 8 x D 6 0 x H 1 0 Weight 1 5 Ibs Compliance UL CE FCC Class A NEBS Level 3 Temperature Standard Operating 0 to 50 C Wide Operating 40 to 60 C Humidity 5 to 95 non condensing Altitude 100m to 4 000m MTBF hrs 250 000 100 000 260 000 260 000 2 700 000 Effective range is 18 to 60VDC when using a module without dying gasp support 4 0 CUSTOMER SUPPORT INFORMATION If you encounter problems while installing this product contact Omnitron Technical Support Phone Fax Address 949 250 6510 949 250 651
5. age 7 for wide temperature ranges Installation of the equipment should be such that the air flow in the front back and top vents of the chassis are not compromised or restricted Never use this equipment to carry any weight except its own Never use it as a shelf to support weight of other equipment 2 4 DC Powered Chassis Mounting Locate the DC circuit breaker of the external power source and switch the circuit breaker to the OFF position Prepare a power cable using a three conductor insulated wire not supplied with a 14 AWG gauge minimum Cut the power cable to the length required Strip approximately 3 8 of an inch of insulation from the power cable wires Connect the power cables to the iConverter Chassis by fastening the stripped ends to the DC power connector Route the power cables through the provided strain relief for additional support Page 5 WARNING Note the wire colors used in making the positive negative and ground connections Use the same color assignment for the connection at the circuit breaker Connect the power wires to the circuit breaker and switch the circuit breaker ON If any modules are installed their Power LED should indicate the presence of power If installing with the NEBS Mounting Kit for 8242 9 and 8243 9 models secure the grounding wire to the ground lug See Figure 3 for the location of the grounding lug NEBS Grounding Strain Relief Fig 3 Rear of 1 Module Power Chassis
6. l 8240 x and 8241 x Model 8242 x and 8243 x Fig 1 1 Module Power Chassis Shown without modules installed This User Manual describes the following models 1 Module 1 Module 1 Module 1 Module 1 Module Chassis Tvpe Chassis Chassis Chassis Chassis Chassis yP US AC Universal AC US AC Universal AC e Adapter Adapter Adapter Adapter A Module Chassis 8240 1 8240 2 8242 1 8242 2 8242 9 3 3 Watts 3 3 Watts 8 3 Watts 8 3 Watts 8 3 Watts Jeg 8241 1 8241 2 8243 1 8243 2 8243 9 Support 5 Watts 5 Watts 8 3 Watts 8 3 Watts 8 3 Watts Wall Mount Hardware Kit EN DIN Rail Mounting Kit ooo NEBS Grounding Kit N A 9123 0 For wide temperature 40 to 60 C add a W to the end of the model number Consult factory for extended temperature 40 to 75 C models 1 1 Dying Gasp Trap The 8241 1 8241 2 8243 1 8243 2 and 8243 9 chassis feature Dying Gasp Trap which reports loss of power input or chassis power supply failure This feature requires an iConverter management module be installed in the chassis When power failure occurs the chassis reserves enough power to keep the installed module running in order to send a final SNMP alert to the management software Page 3 2 0 INSTALLATION 2 1 Installing Module Carefully slide the module into the open slot in the chassis Align the module with the installation guides and ensure that the module is firmly seated against the backplane Secure
7. llation and shall be a UL listed circuit breaker rated 20 Amps and installed per the National Electrical Code ANSI NFPA 70 This equipment requires 20 60VDC 0 6Amp rated power Appropriate overloading protection should be provided on the DC power source outlets utilized WARNING Only a DC power source that complies with safety extra low voltage SELV requirements can be connected to the DC input power supply WARNING REGARDING EARTHING GROUND o This equipment shall be connected to the DC supply system earthing electrode conductor or to a bonding jumper from an earthing terminal bar or bus to which the DC supply system earthing electrode is connected This equipment shall be located in the same immediate area such as adjacent cabinets as any other equipment that has a connection between the earthed conductor of the same DC supply circuit and the earthing conductor and also the point of earthing of the DC system The DC system shall not be earthed elsewhere The DC supply source is to be located within the same premises as this equipment There shall be no switching or disconnecting devices in the earthed circuit conductor between the DC source and the earthing electrode conductor The standard operating temperature of this equipment is 0 to 50 degrees C If installed in a closed or multi module rack assembly the operating ambient temperature of the rack must not exceed the maximum rated 50 degrees C See specifications on p
8. st be sent to an Omnitron designated facility at Buyer s expense Omnitron will pay the shipping charge to return the product to Buyer s designated US address using Omnitron s standard shipping method Limitation of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate use and or maintenance of the equipment by Buyer Buyer supplied equipment Buyer supplied interfacing unauthorized modifications or tampering with equipment including removal of equipment cover by personnel not specifically authorized and certified by Omnitron or misuse or operating outside the environmental specification of the product including but not limited to voltage ambient temperature radiation unusual dust etc or improper site preparation or maintenance No other warranty is expressed or implied Omnitron specifically disclaims the implied warranties of merchantability and fitness for any particular purpose Exclusive Remedies The remedies provided herein are the Buyer s sole and exclusive remedies Omnitron shall not be liable for any direct indirect special incidental or consequential damages whether based on contract tort or any legal theory Page 2 iConverter 1 Module Power Chassis User Manual 1 0 GENERAL DESCRIPTION The 1 Module iConverter Power Chassis supports a single iConverter module and is powered by an external AC power adapter or an external DC power source 20 to 60VDC Mode