1. P IS ode For reference also attach your receipt or a copy of your receipt to the manual For Your Records and Warranty Assistance 0 a 3 VI INI NAI J F n Owner s Guide and Installation Manual Where Purchased SINCE 1886 Form 45003 01 20110712 2011 Hunter Fan Co Welcome Your new Hunter ceiling fan is an addition to your home or office that will provide comfort and performance for many years This installation and operation manual gives you complete instructions for installing and operating your fan We are proud of our work We appreciate the opportunity to supply you with the best ceiling fan available anywhere in the world Before installing your fan for your records and warranty assistance record information from the carton and Hunter nameplate label located on the top of the fan motor housing Cautions and Warnings e READ THIS ENTIRE MANUAL CAREFULLY BEFORE BEGINNING INSTALLATION SAVE THESE INSTRUCTIONS Table Of Contents e Use only Hunter replacement parts Preparing the Fan Site e To reduce the risk of personal injury attach the fan directly to the support structure of the building according to these instructions and use only the hardware supplied To avoid possible electrical shock before installing your fan 3 Assembling and Hanging the Fan 8 disconnect the power by turning off the circuit breakers to the 4 Wiring the Fan outlet box and
2. and ANSI NFPA 70 If you are unfamiliar with wiring use a qualified electrician Installer s Choice and Optional Accessories Support Brace Ceiling Standard Outlet Box Mounting gt Style Standard Mounting hangs from the ceiling by a downrod included Mounting Angled Mounting recommended for a vaulted or angled ceiling Understanding Mounting and Installers Choice Hunter s patented mounting system provides you maximum installation flexibility and ease You can install your Hunter fan in one of two ways depending on ceiling height and your preference Standard or Angled mounting The steps in this manual include instructions for both Installer s Choice mounting methods Considering Optional Accessories Consider using Hunter s optional accessories including a wall mounted or remote speed control To install and use the accessories follow the instructions included with each product For quiet and optimum performance of your Hunter fan use only Hunter speed controls For ceilings higher than 8 feet you can purchase Hunter extension downrods All Hunter fans use sturdy 3 4 diameter pipe to assure stability and wobble free performance A CAUTION To reduce the risk of personal injury attach the fan directly to the support structure of the building according to these instructions and use only the hardware supplied 5 45003 01 07 12 2011 Hunte
3. associated wall switch location If you cannot lock the circuit breakers in the off position securely fasten a prominent warning device such as a tag to the service panel All wiring must be in accordance with national and local electrical codes and ANSI NFPA 70 If you are unfamiliar with wiring use a 7 Completing Your Installation With a qualified electrician Bowl Light Fixture 1 Getting Ready 2 Installing the Hanger Bracket 5 Installing the Canopy and Canopy Trim 6 Assembling the Blades To reduce the risk of personal injury do not bend the blade 8 Assembling the Remote Control and attachment system when installing balancing or cleaning the fan Mounting the Cradle Never insert foreign objects between rotating fan blades To reduce the risk of fire electrical shock or motor damage do not use a Solid state speed control with this fan Use only Hunter speed controls which are solid state e This product conforms to UL STD 507 and is certified to STD C22 2 No 113 e Wash your hands after your fan installation is complete 9 e Operating and Cleaning Your Ceiling 10 Troubleshooting 2011 Hunter Fan Company 2 45003 01 07 12 2011 Hunter Fan Company Preparing the Fan Site Step 1 Choose the Fan Site Proper ceiling fan location and attachment to the building structure are essential for safety reliable operation maximum efficiency and energy savings Choose a fan s
4. electrical supply house 4 2 Orient the outlet box so that both the inner and outer holes in the box align with the joist or support brace 4 3 Drill pilot holes no larger than the minor diameter of the wood screws 5 64 through the inner holes of the outlet box 4 4 Attach the outlet box directly to the support brace or joist with two 8 x 1 1 2 wood screws and washers The bottom of the outlet box must be recessed a minimum of 1 16 into the ceiling Step 5 Prepare the Wiring 5 1 Make sure the circuit breakers to the fan supply line leads and associated wall switch location are turned off If you cannot lock the circuit breakers in the off position securely fasten a prominent warning device such as a tag to the service panel 5 2 Thread the fan supply line through the outlet box so that the fan supply line extends at least 6 beyond the box 5 3 Attach the fan supply line to the outlet box with an approved connector available at any hardware store or electrical supply house 5 4 Make certain the wiring meets all national and local standards and ANSI NFPA 70 You have now successfully prepared your ceiling fan site For instructions to install your ceiling fan go to your fan manual and continue with Section 2 Installing the Ceiling Plate 4 45003 01 07 12 2011 Hunter Fan Company A CAUTION All wiring must be in accordance with national and local electrical codes
5. in diameter Note Your fan comes with four pre installed neoprene noise ad i racKe isolators panpin Thread the lead wires from the outlet box down through the hole ai in the middle of the hanger bracket a Align the slotted holes in the hanger bracket with the pilot holes Z you drilled in the wood support structure For proper alignment E use slotted holes directly across from each other If you are installing the fan on an ANGLED ceiling be sure to orient the hanger bracket as shown in Illustration 2 3 left or right view Note The isolators should be flush against the ceiling Place a flat washer on each of the two 3 screws and pass the screws through the slotted holes in the hanger bracket into the pilot holes you drilled Tighten the screws into the 9 64 pilot holes do not use lubricants r on the screws Do not over tighten Flat Washer Steps 2 2 2 4 Ceiling Peak Ceiling Peak Large A Opening Large 3 Screw LEFT ALAALA a Step 2 3 Angled Ceiling Only y 7 45003 01 07 12 2011 Hunter Fan Company 3 1 3 2 3 3 3 4 3 Assembling and Hanging the Fan To assemble fan to hang down from a flat or angled ceiling place the canopy and canopy trim ring around the adapter so that they rest on the fan assembly Feed the wires from the fan through the downrod Note Make sure all the wires are on the same side of
6. of the heater vent and twist it as shown to tighten it against the glass bowl Switch Housing Screws 3 Light Bulbs B10 Candelabra Base 40 Watt Maximum a Threaded Portion of Heater Vent lt Finial Glass Bowl 14 45003 01 07 12 2011 Hunter Fan Company 8 1 8 2 8 Assembling the Remote Control and Mounting the Cradle To install the battery remove the back cover of the remote Insert the included 12 volt alkaline battery Type 23A MN 21 or equivalent inside the remote matching polarity on the battery as indicated by the and symbols in the battery compartment Replace the cover If you are using more than one remote controlled fan in the same area and want to control them separately you must change the DIP switch settings in the remote before you install the battery For instructions on setting the DIP switches read the box on the next page To install the remote cradle on a switch plate remove the two screws holding the switch cover plate Do not remove the cover plate Note If you are installing the remote cradle on a rocker light switch first break off the two tabs by pushing outward Orient the control cradle by lining up the two mounting holes with those on the switch Insert and tighten the screws do not over tighten To install the remote cradle on the wall locate a 2 x 4 wall stud in a convenient location Orient the remote cradle o
7. the metal dowel pin inside the downrod Loosen the square head set screw on the adapter to install the pipe and ball assembly Note When the pipe and ball assembly is fully installed 2 3 threads on the pipe will still be visible this is normal Securely retighten the set screw with a wrench or pliers A CAUTION The adapter has a special coating on the threads Do not remove this coating the coating prevents the downrod from unscrewing Once assembled do not remove the downrod A WARNING Do not carry or lift fan by canopy Raise the fan and place the ball into the hanger bracket 3 5 Align the notch on the ball with the indent in the hanger bracket Rotate the fan until you hear the notch pop into place Go to 4 e Wiring the Fan A WARNING Fan may fall if not assembled as directed in these installation instructions 8 Steps 3 1 3 3 7 m Downrod lt Canopy with Washer Canopy Trim Adapter Ring Steps 3 4 3 5 45003 01 07 12 2011 Hunter Fan Company 4 Wiring the Fan All wiring must be in accordance with national and local electrical codes and ANSI NFPA 70 If you are unfamiliar with wiring use a qualified electrician Wall switches are not included Select an acceptable general use switch in accordance with national and local electrical codes 4 1 4 2 4 3 4 4 4 5 4 6 4 7 Before attempting installation make sure
8. the power is still off To connect the wires hold the bare metal leads together and place a wire connector over them then twist clockwise until tight For all these connections use the wire connectors provided Connect the bare or green ground wire grounding from the ceiling to the green ground wire grounding from the ceiling plate and the green ground wire from the fan Connect the white wire grounded from the ceiling to the white wire grounded from the fan Connect the remaining wires as follows e The black wire ungrounded from the ceiling to the black ungrounded and the black white wire ungrounded from the fan A CAUTION Be sure no bare wire or wire strands are visible after making connections Turn the wire connectors upward and push them carefully back through the ceiling plate into the outlet box Spread the wires apart with the grounded wires on one side of the outlet box and the ungrounded wires on the other side of the outlet box 9 Wire Connector 45003 01 07 12 2011 Hunter Fan Company 5 1 5 2 5 3 5 4 5 Installing the Canopy and Canopy Trim Ring Partially install two canopy screws about 2 full turns in the hanger bracket Raise the canopy over the hanger bracket Align partially installed screws with key slots in canopy Twist canopy clockwise to secure Install third amp fourth canopy screw in round hole on canopy Securely tighte
9. ite where e No object can come in contact with the rotating fan blades during normal operation e The fan blades are at least 7 feet above the floor and the ceiling is at least 8 feet high The fan blades have no obstructions to airflow such as walls or posts within 30 inches of the fan blade tips e The fan is directly below a joist or support brace that will hold the outlet box and the full weight of the fan Checklist for Existing Fan Site s 30 From Wall or Nearest Obstruction 7 Minimum Blades to Floor If you want to use an existing fan site complete the following checklist to Fan Support determine if the site is acceptable and safe for your new Hunter fan If you cannot check off every item prepare a new fan site as described on this page Fan Support System e Fan attaches directly to building structure e Fan support system will hold full weight of the fan and light kit Ceiling Hole e The outlet box clearance hole is directly below the joist or support brace Outlet Box e The outlet box is an UL approved octagonal 4 x 1 1 2 outlet box or as specified by the support brace manufacturer e The outlet box is secured to the joist or support brace by wood screws and washers through the inner holes of outlet box The outer holes of the outlet box are aligned with joist or support brace e The bottom of the outlet box is recessed a minimum of 1 16 into ceiling Wiring The elec
10. n all four screws Using both hands push the canopy trim ring up to the top of the canopy Twist canopy trim ring clockwise to secure the canopy Should you need to remove the canopy trim ring follow these steps 1 Twist canopy trim ring counter clockwise until it releases from canopy 10 45003 01 07 12 2011 Hunter Fan Company Steps 5 1 5 2 Hanger Bracket gt Canopy Trim PA Ring Step 5 3 6 Assembling the Blades Step 6 1 Detail Hunter fans use several styles of fan blade irons brackets that hold the blade to the fan 6 1 Your fan may include blade grommets If your fan has grommets insert them by hand into the holes on the blades 6 2 Attach each blade to a blade iron using three blade assembly screws If you used grommets the blades may appear slightly loose after screws are tightened This is normal 6 3 Remove the blade mounting screws and rubber shipping bumpers from the motor Note Some blade mounting screws are installed in the motor to secure shipping blocks 6 4 For each blade insert one blade mounting screw through the blade iron and attach lightly to the fan Insert the second blade mounting screw then securely tighten both mounting screws Note The blades on this fan have been treated Steps 6 1 6 2 with Hunter s Dust Armor protection making C the blades less likely to attract dust and di
11. ontrol 1 CFL light bulbs are not usually made for dimming Replace the CFL bulbs with dimmable light bulbs or install the fan in a location without a dimming control If you need parts or service assistance please call 888 830 1326 In Canada call 866 268 1936 or visit us at our website at http www hunterfan com Hunter Fan Company 7130 Goodlett Farms Parkway 400 Memphis Tennessee 38016 18 45003 01 07 12 2011 Hunter Fan Company
12. power off at the circuit breaker for the previously installed fan as you may inadvertently change the DIP switch code settings for it as well Slide the cover off the back of the remote and remove the battery The battery must be removed when changing DIP switch settings Refer to Step 8 1 Change the DIP switch settings so that they are different from the previously installed fan 4 Replace the battery and cover 5 At the circuit breaker or fuse box turn the power back on for the fan whose settings you are changing Within 20 seconds of restoring power push the 3 high 2 medium and 1 low buttons in that order on the remote Note The receiver built into the fan has a memory function that retains the last DIP switch code setting The setting will not change in the event of power failure or if the power to the fan is inadvertently shut off 16 45003 01 07 12 2011 Hunter Fan Company 9 Operating and Cleaning Your Ceiling Fan Fan Operation To start the fan press the speed button on the remote at the level you desire e 3 for high e 2 for medium e 1 for low To turn off the fan press the 0 button on the remote Light Operation The light button is used to turn on dim and turn off the light To Turn the light on e Press the light button 1 time and the light will come on to the previously set level To dim the light e Press and hold the light button until the light has reached
13. r Fan Company l Getting Ready To install a ceiling fan be sure you can do the following e Locate the ceiling joist or other suitable support in ceiling e Drill holes for and install wood screws e Identify and connect electrical wires e Lift 40 pounds If you need help installing the fan your Hunter fan dealer can direct you to a licensed installer or electrician Gathering the Tools You will need the following tools for installing the fan e Electric drill with 9 64 bit e Standard screwdriver magnetic tip recommended e Phillips head screwdriver magnetic tip recommended e Wrench or pliers e Ladder height dependent upon installation site Checking Your Fan Parts Carefully unpack your fan to avoid damage to the fan parts Refer to the included Parts Guide Check for any shipping damage to the motor or fan blades If any parts are missing or damaged contact your Hunter dealer or call Hunter Technical Support Department at 888 830 1326 In Canada call 1 866 268 1936 6 Installing Multiple Fans If you are installing more than one fan keep the fan blades and blade irons if applicable in sets as they were shipped 45003 01 07 12 2011 Hunter Fan Company 2 2 2 3 2 4 Drill two pilot holes into the wood support structure through the 2 Installing the Hanger Bracket outermost holes in the outlet box The pilot holes should be 9 64 Isolator
14. rt ia Siaa ain Use a dry or slightly damp lint free cloth to e clean the blades Do not use a furniture polish i or any other cleaners that leave any residue as they will damage the protective Dust Armor on the blades Use with grommet Blade Assembly Screws Use without grommet lI 45003 01 07 12 2011 Hunter Fan Company 7 Completing Your Installation With a Bowl Light Fixture Your Hunter fan comes with an integrated light fixture assembly A WARNING Use only the light fixture supplied with this fan model 7 1 To attach the upper switch housing partially install two housing assembly screws into the switch housing mounting plate 7 2 Feed the upper plug connector through the center opening of the housing 7 3 Align the keyhole slots in the housing with the housing assembly screws 7 4 Turn the housing counterclockwise until the housing assembly screws are firmly situated in the narrow end of the keyhole slots Install the remaining screw into the housing Tighten all three Steps 7 1 7 3 screws firmly Housing i er A CAUTION Make sure the upper switch housing is securely n ey yee attached to the switch housing mounting plate Failure to properly Housing attach and tighten all three assembly screws could result in the switch housing and or light fixture falling 12 45003 01 07 12 2011 Hunter Fan Company 7 3 7 6 To at
15. tach the lower switch housing connect the upper plug connector from the motor to the lower plug connector in the lower switch housing assembly Note Both plug connectors are polarized and will only fit together one way Make sure the connectors are properly aligned before connecting them Incorrect connection could cause improper operation and damage to the product Place the lower switch housing assembly over the upper switch Plug Connector housing Align the side screw holes in the upper and lower switch housings Attach the lower switch housing to the upper switch housing with three housing assembly screws Note In compliance with US federal energy regulations this ceiling fan contains a device that restricts its light output Exceeding the wattage limit marked on the MAX wattage sticker affixed to the light socket s may result in fire hazard or improper operation Steps 7 5 7 6 Lower Switch Housing Plug T Connector Detail Housing _ Assembly Screw 13 45003 01 07 12 2011 Hunter Fan Company 7 Completing Your Installation With a Bowl Light Fixture Continued Installing the Glass Bowl 7 7 First install B10 candelabra bulbs 40 Watt Maximum into the sockets 7 8 Place the glass bowl over the heater vent ensuring the threaded portion of the heater vent comes out of the bottom of the glass bowl Place the finial over the threaded portion
16. ter will be at the previous settings 45003 01 07 12 2011 Hunter Fan Company 10 Troubleshooting Problem Nothing happens fan does not move 1 Turn power on replace fuse or reset breaker 2 Loosen canopy check all connections according to the wiring the fan section 3 Check the plug connection in the switch housing 4 Push motor reversing switch firmly left or right to ensure that the switch is engaged 5 Pull the pull chain to ensure it is on 6 Remove the shipping bumpers Problem Noisy operation 1 Tighten the blade assembly screws and blade iron armature screws until snug 2 Check to see if the blade is cracked If so replace all the blades Problem Excessive wobbling 1 Make sure the blades are securely attached to the blade irons according to the blade assembly instructions provided 2 After thoroughly verifying the blades are securely attached to the blade irons follow the instructions in the enclosed balancing kit to balance the fan 3 Turn power off support fan very carefully and check that the hanger ball is properly seated Problem Lights shut off suddenly but fan is still operating 1 Check to make sure the wattage and type of the light bulbs that are installed meet the specifications on the light socket 2 Turn the power to the fan off at the wall switch Wait 5 minutes then resume power to the fan Problem CFL bulbs flicker when controlled by a dimming remote or wall c
17. the desired level As you hold the button the light level will move throughout its entire range within 16 seconds Release the button at the desired level To Turn the light off e Press the light button 1 time for gradual off and the light will dim automatically for approximately 20 seconds until all the way off to allow for safe exit from the room e Press the light button 2 times or 1 time while the light is dimming for instant off Heater Operation The heater button is used to turn on and off the heater e Press the heater button 1 time to turn the heater on e Press the heater button again to turn the heater off Note To assure the maximum benefit of the heater function Regardless of the speed setting on the fan when the ceiling fan is operating and the heater function is turned ON the ceiling fan automatically switches to low speed updraft only and will not accept any commands from the remote until the heater is turned off 17 Light my Heater Fan Medium Fan Low Fan High Fan Off Reversing Switch Steps 9 1 9 2 Normal Operation The heater must be turned off Heater Function make sure the ceiling fan is turned off AUTO RESUME FEATURE This fan contains a receiver with an auto resume feature The receiver remembers the intensity of the light speed and direction of the fan and whether the heater is on or off When power is restored to the receiver the fan light and hea
18. trical cable is secured to outlet box by an approved connector e Six inches of lead wires extend from outlet box Fan Support Outlet Box System Suitable Existing Fan Site If your existing fan site is suitable skip ahead to Section 2 Installing the Ceiling Plate 3 45003 01 07 12 2011 Hunter Fan Company 8 Minimum Ceiling Height Preparing the Fan Site continued Step 2 Cut the Ceiling Hole 2 1 Locate the site for the ceiling hole directly below the joist or support brace that will hold the outlet box and fan 2 2 Cut a 4 diameter hole through the drywall or plaster of the ceiling You will use the hole to install the support brace and outlet box Step 3 Install a Support Brace If Necessary Determine if there is a ceiling joist directly above the ceiling hole If the joist is there determine if it is positioned to allow you to recess the outlet box a minimum of 1 16 into the ceiling If NOT install a support brace as follows 3 1 Attach a 2 x 4 support brace between two joists Position it to allow you to recess the bottom of the outlet box a minimum of 1 16 into the ceiling 3 2 Check the support brace to ensure it will support the full weight of the fan and light kit Step 4 Install the Outlet Box 4 1 Obtain a UL approved octagonal 4 x 1 1 2 outlet box plus two 8 x 1 1 2 wood screws and washers available from any hardware store or
19. ver the 2 x 4 stud Use 1 wood screws in either the inner or outer mounting holes Wall anchors and 6 32 x 1 screws may be used in situations where mounting to a stud is not possible Use the inner mounting holes A CAUTION The remote control device complies with part 15 of the FCC rules Changes or modifications not expressly approved by Hunter Fan Company could void your authority to operate this equipment Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation Note Use with a fan that incorporates an air gap switch normal on off wall switch A WARNING Maximum fan load is 100 Watts maximum lamp is 120 Watts Do not use any speed control with this product 15 Step 8 2 Removed Tabs Step 8 2 Rocker Light Switch 45003 01 07 12 2011 Hunter Fan Company 8 Assembling the Remote Control and Mounting the Cradle Continued Setting the DIP switches You will only have to change the DIP switch settings in the remote if you are using more than one remote controlled fan in the same area and want to control them separately You may want to label your remotes to ensure you do not mix them up 1 At the circuit breaker or fuse box turn the power off for the fan you want to change Do not turn the