Home
Argoclima Jonio Professional
Contents
1. Jonio Professional Air purifier With UV lamp and photocatalytic filter FEATURES INDEX ANION MODE Safety precautions 3 positive ions abound in air they are emitted by several appliances such as radio and television In the mode Air purifier description 4 ANION several negative ions are emitted they abound naturally in places where there are feelings of Control panel and remote control 5 well being such as in the mountains Air becomes fresh such as air in the montains PHOTOCATALYSIS MODE In this mode bad smells released from wall paper Maintenance of the appliance 6 Troubleshooting ceceeeees 8 furniture detergents for cleaning moulds virus and bacteria smoke from cigarettes gases from bad combustion of wood stoves or chimneys such as carbon monoxide dust even fine dust such as PM10 and PM2 5 are reduced Moreover even concentrations of toxic gases in the air such as benzene trichloroethylene formaldehyde ammonia sulphur dioxide are reduced Due to the action of UV lamps the effectiveness of the photocatalytic filter towards gases is hundreds of times higher then the action of the activated carbon filter commonly present in air purifiers and in aspirant hoods It does not need to be sustituted It holds particles with a diameter lower than the dimensions of the particles held by the HEPA filter In mode PHOTOCATALYSIS the function ionization and 2
2. UV lamps are working at the same time STERILIZATION MODE Similar to the mode PHOTOCATALYSIS but in this mode besides ionization also 3 UV lamps are working HEPA filter it holds hair from animals pollens and particles with diameter higher than 0 3 micron SAFETY PRECAUTIONS Read carefully these instructions before using the appliance Before operating the appliance check that the technical data declared on the plate conform to the voltage of the electrical supply network Place the appliance on a flat and stable surface Keep at least 60 cm distance from curtains furniture walls and other surfaces that could be an obstacle to the air flow For a better circulation of the air we suggest to keep the air puirfier at least at 50 cm from the floor Do not use it if the power cord is damaged or if the plug is loose in order to avoid electric shock shirt circuits and fires Do not damage the cable by pulling the appliance by the cord do not run it around sharp edges do not wind it do not put on the cable heavy objects do not put it near hot surfaces In order to remove the plug pull by the plug and not by the cable Before removing the plug switch off the appliance In order to move the appliance use the handle on the rear of the appliance Do not use extension cords Do not modify the appliance If the appliance needs to be repaired or the cable needs to be substituted please contact an argo service centre Before cleaning the
3. same direction of the holes that hold the lamp and remove it by pressing towards the bottom the lower part of the lamp and towards yourself the upper extremity at the same time Insert the new lamp in the holes and turn it into clockwise direction in order to fix Reassembly of the front panel In order to assembly the front panel lean it on the upper hooks or the frame and press the front panel on the frame in order to assembly it Cleaning of the photocatalytic filter Every two weeks place the appliance in mode regeneration for 1 4 hours by pressing the button REVIVAL in order to make the cleaning of the photocatalytic filter and to work with the maximum efficiency of air purification MAINTENANCE INDICATOR When the indicator MAINTENANCE lights do as follows rinse the pre filter with water and neutral detergent and let it dry naturally Do not damage it by scrubbing it or wring it The prefilter needs to be washed every two weeks and changed every month Check the HEPA filter and substitute it before it becomes dark dark filter has not got any efficiency of filtration When the maintenance job is finished and the HEPA filter has been substitued please use a needle in order to press the button RESET and switch off the indicator TROUBLESHOOTING HEPA filter is dirty PROBLEM CAUSE SOLUTION Air purifier does not The plug does not fit correctly into the Fit correctly the plug into the work socket
4. appliance or substituting the filters switch it off and remove the plug Never touch the plug of the air purifier with wet hands The appliance is equipped with antidip protection therefore it should be used only inside houses and far away from rocks wash basins or similar places where there could be presence of humidity Do not immerse it into water or other liquids Do not run it near a heater Do not use it near flammable gases such as natural gas or propane Do not run the appliance without HEPA filter otherwise some UV light could get out of it Keep the appliance far away from children and invalids in order to avoid accidents Do not clean the appliance with solvents or petroline Do not clean UV lamps with water use only dry clothes Do not insert fingers and or other objects into air openings During periods of long inactivity unplug the appliance from the socket Batteries must be removed from the remote control before the appliance is scrapped and must be thrown in proper bins for batteries DESCRIPTION OF THE AIR PURIFIER So io 7 a Control panel UV lamp 3 pieces HEPA filter Prefilter Photocatalytic filter Prefilter cover Control panel air flow entrance Lo momoo D gt Remote control Handle Air flow exit Ca ae Supply cord 1 Pre filter Its main function is to filter the biggest particles and then as a consequence the life of the HEPA filter can be longer 2 HEPA filte
5. r It can filter particulate with a diameter higher than 0 3 micron and effectively remove pollens smoke hair from animals moulds and dust 3 Photocatalytic filter Together with the light emitted by UV lamps its power of purification towards gases is 300 hundreds times more effective than activated carbon filter It can effectively decompose toxic gases and viruses without secondary products It has the property of decomposing toxic gases and viruses without secondary products Moreover it has the particular properties of regeneration and self cleaning and at least theorically it does not need to be substituted 4 lonizer It supplies a big quantita of negative ions CONTROL PANEL AND REMOTE CONTROL i tt o La ih H penn ee ELA BEAL AAS H G F E D C B A ON OFF ANION IONIZATION PHOTOCATALYSIS STERILIZATION REVIVAL WIND TIMER UV LAMPS LIGHT FOR FILTER SUBSTITUTION MAINTENANCE h d J RESET Oo 7 PMO TION PO The air purifier can be used both with the control panel and with the remote control Switch on off Press button ON OFF A the indicator will light The appliance begins to work in PHOTOCATALYTIC mode purification at the intermediate speed and two UV lamps will be on Setting the speed Set wind speed HIGH MEDIUM LOW by pressing the button WIND Switch on time selection Press the button TIMER G in order to set the switch on time 1hr 2hr 4hr 8hr When the indicator is off the
6. socket The plug or the socket are loose or Check the plug and the broken socket The front panel is not fixed Check the front panel and substitute it Remote control does The battery is not inserted The battery is Replace the battery not work exhausted The remote control has not been aimed Aim it correctly correctly towards the appliance There is an obstacle between the Remove the objects in the remote control and the appliance path Low efficiency of Pre filter is dirty Clean change the filter filtration The grids for air intake outlet are dirty Remove the obstacles Substitute HEPA filter www argoclima com MADE IN CHINA
7. tch off the air purifier and remove the plug from the socket before disassembling or assembling the appliance The appliance needs substitution of the prefilter HEPA filter and lamps according to the suggested frequency The life of the filters of the HEPA filter and of the lamps change according to the hours of use Do not clean the air purifier with water or other liquids Front panel assembly and disassembly Take the lower part of the front panel and move it towards yourselves and towards high Pay attention to protect the interlock switch that is in the top high angle just below the front panel When the front panel is removed the appliance will switch off automatically If the interlock device is destroyed the unit will not work Substitution of the prefilter suggested every month The prefilter can be washed we suggest to substitute at least every month In the package of the appliance when you buy it 6 prefilters are included In order to substitute it you have to remove the front panel and press towards the bottom the black tongues Substitution of the HEPA filter suggested every 6 months Remove the front panel remove the prefilter and extract the HEPA filter Place a new HEPA filter and then the prefilter Place at its place the front panel Substitution of the UV lamps medium life 5 000 8 000 hours Keep with your hands the lower and upper extremities of the lamp and turn it into anticlockwise direction till it is in the
8. timer is not selected lonization function By pressing the button ANION B some negative ions will be generated Photocatalysis and sterilization function by pressing the button PHOTOCATALYSIS and STERILIZATION the process of photocatalysis and ionization will take place at the same time If the function of sterilization is selected with the timer the appliance will set automatically to PHOTOCATALYSIS mode Revival In the mode revival only two UV lamps will be on without letting the motor work The revival function is needed in order to clean the photocatalytic filter by means of UV lamp without air circulation UV lamps status Three indicator will light in the top left angle of the control panel and show the status of the UV lamps When the appliance work in photocatalysis mode two indicators will light While we are in mode sterilization three indicators will light If no indicator will light you must check the UV lamps they could be broken d UV1 UV2 w3 pHorocaTavsis o o emmen of oTo REVIVAL UN status O The uv lamp is on The uv lamp is off You have to use the remote control towards the main unit and the receiver Make sure that there are no objects in the path of the signal In the moment during which the main unit receives the signal a sound will be emitted Avoid to damage the remote control Do not expose it to the sunlight or near a heater APPLIANCE MAINTENANCE Swi