1. Use the following DNS server addresses Preferred DNS server Alternate DNS server Figure 2 Internet Protocol TCP IP Properties Window 1 2 Connecting via a Straight through Cable You can connect the Ethernet port of the Kramer Machine to the Ethernet port on a network hub or network router via a straight through cable with RJ 45 connectors KRAMER SIMPLE CREATIVE TECHNOLOGY Installing and Running the DevicelInstaller M Configuration Software 2 Installing and Running the Devicelnstaller Configuration Software To configure your Kramer Machine via the Ethernet install the Devicelnstaller configuration software and configure your Ethernet Port and then install the COM Port Redirector to control the Kramer Machine To configure the Ethernet Port you must install and run the DevicelInstaller configuration software It is important to consider the following points before logging into and configuring the Ethernet Port e The Kramer Machine IP address must be configured before a network connection is available if you encounter problems see Section 1 1 e Only one person at a time may be logged into the network port This eliminates the possibility of several people simultaneously attempting to configure the Device Server e Network port logins can be disabled The system manager will not be able to access the unit This port can also be password protected 2 1 Instal
2. ooo ooo ooo eio 0 0 0 0 0 0 0 0 ce Figure 16 Hostlist Settings Window Note In order to work in the active mode the remote host IP address and port number have to be added to the Hostlist Settings table 12 KRAMER SIMPLE CREATIVE TECHNOLOGY Installing and Running the DeviceInstaller Configuration Software Figure 17 Shows the Connection Settings window Device Details Web Configuration Telnet Configuration i Network Server Serial Tunnel Hostlist Channel 1 Serial Settings Email Trigger 1 Trigger 2 Trigger 3 Configurable Pins Apply Settings Apply Defaults itEp 172 17 9 200 securejltx conf htm Firmware Version V6 5 0 3 MAC Address 00 20 4A 8C 09 A7 Connection Settings Channel 1 Connect Protocol Protocol Connect Mode Passive Connection Accept incoming Password Required C Yes No Active Connection Active Connect With Any Character v Start Character 90 in Hex Modem Mode None Modem Escape Sequence Pass Through Endpoint Configuration Local Port Remote Port Common Options Telnet Mode Disable v Terminal Name Disconnect Mode On Mdm Ctrl In Drop Yes 9 No Check EOT Ctrl D Yes 9 No C Auto increment for active connect Remote Host 172 16 8 167 ConnectResponse None Sj Use Hostlist Yes No Hard Disconnect Yes ONo Inactivity Timeout o 0 tmin
3. Installation Window 6 Click the Next button The installation begins then a warning message is displayed indicating that CPR has not passed Windows Logo testing 17 Installing and Configuring the Com Port Redirector Software Software Installation AN The software you are installing has not passed Windows Lago testing to verfu its compatibility with Windows P Tell me why this testing is important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the software vendor for software that has passed Windows Logo testing Continue Anyway STOP Installation Figure 22 Security Confirmation Window 7 Click the Continue Anyway button The installation continues and the warning is displayed again 8 Click the Continue Anyway button again The installation continues until the Installation Complete window is displayed i Lantronix CPR Installation Complete Lantronix CPR has been successtully installed Click Close to exit Please use Windows Update to check for any critical updates to the WET Framework Close Figure 23 Installation Complete Window 9 Click the Close button 18 KRAMER SIMPLE CREATIVE TECHNOLOGY Installing and Configuring the Com Port Redirector Software 3 2 Configuring the Com Port Redirecto
4. Listen Mode Normal port closed after disconne TCP Port Add To Firewall TCP Keep live 7200000 KeepAlive Time msec KeepAlive Interval msec F RFC 2217 DTA In TruPort Service Host TCP Port a WARNING If the Host is on the other side of a router or a remote firewall then UDP ports 30718 43282 and 43283 may need to be added to the firewall s exclusion list You may experience trouble opening this com port if these UDP ports are not excluded Also some legacy device servers respond on UDP port 43283 If you are unable to connect to a device server one possible cause is the Firewall on this machine is blocking this port Press the Add Rx Port button to add this port to the Firewall If the button caption reads Remove Rx Port then the port has already been added and can be removed by pressing this button TheFirewallis turned OF F i Device List IP ddress Ports TCP Port Product ID Hw Address Network Interface Device Name Port Name S91 72 17 9 200 1 10001 XPort 03 04 x5 00 20 44 80 09 47 172 17 9 7 Figure 28 Highlighting a Com Port 11 In the Device List pane right click on the device to associate with the com port 22 KRAMER SIMPLE CREATIVE TECHNOLOGY Installing and Configuring the Com Port Redirector Software CPR Manager 4 3 0 0 File ComPort Device Tools Help W Add Remove Refresh 5 Search For Devices amp E
5. Web Configuration Tab The Connect to Window The Web Manager Window Network Settings Window Hostlist Settings Window Connection Settings Window Serial Connection Settings Window Lantronix CPR Welcome Window CPR Welcome window Confirm Installation Window Security Confirmation Window Installation Complete Window Com Port Redirector Main Window Com Ports Window Com Ports Window Showing New Port Devices Found on the Network Highlighting a Com Port Assigning a Device to a Com Port Device Added to Com Port WOo0co 14 0009 N E m m On mn OMmAANANDADNNANA HB WN e Connecting to the Kramer Device via the Ethernet Port 1 Connecting to the Kramer Device via the Ethernet Port You can connect the machine via the Ethernet in the following ways e For direct connection to the PC use a crossover cable see Section 1 1 e For connection via a network hub or network router use a straight through cable see Section 1 2 1 1 Connecting the Ethernet Port Directly to a PC Crossover Cable You can connect the Ethernet port of the Kramer Machine to the Ethernet port on your PC via a crossover cable with RJ 45 connectors This type of connection is recommended for identification of the factory default IP Address of the Kramer Machine during the initial configuration After connecting the Ethernet port configure your PC as follows 1 Right click the My Network Places icon on your desktop 2 Select Pro
6. Web browser 1 Select the Web Configuration tab see Figure 12 Lantronix Deviceinstaller 4 3 0 1 Fla ER Yew Deke Tok Hel j Semud Gp Eschde E AedgnIP Upgrade zi Fig Lantiong Devices 1 develi o nc B nudes Hats 172 17 0 200 80 SP Buren vds 0 3 Please pres the Go bullon 10 mkpag bo He device Dune Deina Web Lonhigursson Telnet Configuration Figure 12 The Web Configuration Tab 2 Select either the internal Web browser GO or the External Browser 3 After clicking GO for the internal browser the Connect to window appears Connect to 172 1 7 9 200 The server 172 17 9 200 at null requires a username and password Warning This server is requesting that your username and password be sent in an insecure manner basic authentication without a secure connection Remember my password Figure 13 The Connect to Window 4 Click OK The Web Manager window is displayed 9 Installing and Running the DevicelInstaller Configuration Software Lantronix Devicelnstaller 4 3 0 1 r 3 z fg Local Area Connection 172 17 87 B ut e ph XPot 03 04 fermare v5 0 3 17217320 MAC Accra 00 20 4A 0C 09 A7 Home Serves Serial Tunne Channel 1 Device Server Configuration Manager Version 1 4 0 4 F mail Conhgurabie Pins Apply Settings Apply Defaults Figure 14 The Web Manager Window 10 KRAMER SIMPLE CREATIVE TECHNOLOGY Inst
7. latest version of which can be downloaded from our Web site at http www kramerelectronics com To configure the Com Port Redirector l From your Windows desktop click Start gt All Programs gt Lantronix gt CPR The Lantronix Com Port Redirector program starts and the main window is displayed 19 Installing and Configuring the Com Port Redirector Software amp OM Manager 4 4 0 0 File ComPet Deio Tod He TeAdiRamevi bej Raf a Sewn hor Devices g occa Com Parti kids Com Pot Let Gerais Tests Com Port IP Acker O Com 1 1 fen Coen 1 lnscceenbtel Een Let IP Address WPuti TCPPut Product D TEP Pot Com Sbn Hw Adest Wehecrk Status Meteo nadace 2X7 iie Dec Mod Device Harte Figure 24 Com Port Redirector Main Window 2 Click Add Remove to add com ports The Com Ports window is displayed Com Ports Ok Select All Select None Com C Comte Com43 C Comt Com45 C Com46 Com4 C Com48 Com43 C Com50 Com51 C Com52 Com53 Comb Com55 C Comb Comb C Com58 Com53 C Comet Figure 25 Com Ports Window Comet Combe Com Com amp 4 Com Com amp B Comb C Com amp 8 Coms C Com Com 1 Com Com 3 Com 4 Com 5 Com Com C Com 8 Com 3 Com amp Check Range Uncheck Range Comiti Comi 02 Comi 3 Com104 Co
8. Kramer Electronics Ltd Ethernet Configuration Guide Lantronix Revision 3 Contents Contents 1 1 1 1 2 2 2 1 2 2 2 3 2 34 2 4 2 9 3 3 1 92 Connecting to the Kramer Device via the Ethernet Port Connecting the Ethernet Port Directly to a PC Crossover Cable Connecting via a Straight through Cable Installing and Running the DeviceInstaller M Configuration Software Installing the DevicelInstaller M Installer Running the DevicelInstaller M Installer Assigning an IP Address Testing the IP Address Configuring the Ethernet Port Using DeviceInstaller Configuring the Ethernet Port Using the Web Manager Page Installing and Configuring the Com Port Redirector Software Installing the Com Port Redirector Software Configuring the Com Port Redirector Figures Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 Figure 14 Figure 15 Figure 16 Figure 17 Figure 18 Figure 19 Figure 20 Figure 21 Figure 22 Figure 23 Figure 24 Figure 25 Figure 26 Figure 27 Figure 28 Figure 29 Figure 30 Local Area Connection Properties Window Internet Protocol TCP IP Properties Window DevicelInstaller Main Dialog Box Device Details selecting the Assignment Method Fill in IP Settings Address Unreachable Window Assign IP Address IP Address Assignment Process Ping Device Window Ping Device Status The
9. Windows security warning is displayed Click Continue Anyway The Windows security warning is displayed again Click Continue Anyway 9 Click Search For Devices to scan the network for devices After a few seconds any devices that are discovered are displayed in the Device List pane Pe DP UN CAN gt CPR Manager 4 3 0 0 De ConPot ewe joos Mp SRefresh p Search for Devices O Lice rede Lom Pot Let Gere Tests All Com Poets 2 Com Pod IP Adbert TCP Pod Com Statue Netescek Status 227 Bi SefRec Nal v Dom 1 frsaccesobie SPots TCP Pot Product Figure 27 Devices Found on the Network 10 In the Com Ports pane select the required com port The com port properties are displayed in the Settings tab in the right hand pane 21 Installing and Configuring the Com Port Redirector Software CPR Manager 4 3 0 0 File ComPort Device Tools Help lg Add Remove haj so 2 Refresh po Search For Devices o Exclude Com Ports i Settings Com 5 Tests All Com Ports 2 Com 5 24 gt Com 1 5 Window s Port Name Lantronix CPR Port COM5 Cor Inace yl i4 Window s Device Name DevicexCprDevice5 Com Status Closed Window s Service Name CprDrvr Network Status Disconnected Reset to Defaults Cancel Edits Buffer Writes Keep checked for better write performance 7 Connection Timeout in seconds C Server Reconnect Timeout Reconnect 0 Reconnect Limit 0 forever C No Net Close C
10. alling and Running the DevicelInstaller Configuration Software Figure 15 shows the Network Settings window Device Details Web Configuration Telnet Configuration Firmware Version V6 5 0 3 MAC Address 00 20 4A 8C 09 A7 fn Network Settings Server Serial Tunnel IP Configuration Hostlist Obtain IP address automatically Channel 1 Auto Configuration Methods Serial Settings Connection BOOTP Enable _ Disable Email DHCP Enable Disable Trigger 1 g mir i AutolP Enable Disable Trigger 2 Trigger 3 Configurable Pins DHCP Host Name Apply Settings Use the following IP configuration Apply Defaults IP Address 172 17 9 200 Subnet Mask Default Gateway 172 17 9 254 Ethernet Configuration Auto Negotiate Speed 100Mbps X 10 Mbps Duplex Full Half Figure 15 Network Settings Window 11 Installing and Running the DevicelInstaller Configuration Software Figure 16 Shows the Hostlist Settings window Network Server Senal Tunnel Channel 1 Serial Settings Connection Email Trigger 1 Trigger 2 Trigger 3 Configurable Pins Apply Settings Apply Defaults Device Details Web Configuration Telnet Configuration Firmware Version V6 5 0 3 MAC Address 00 20 4A 8C 09 A7 Hostlist Settings Retry Settings Retry Counter Bo J Retry Timeout 250 Host Information No HostAddress 172 16 8 11 ME 0 0 0 0 gt 0 0 0 0
11. c IP address Figure 5 Selecting the Assignment Method 3 Fill in the IP address Subnet mask and Default gateway to assign to the device and click Next Assign IP Address IP Settings Please fil in the IP address subnet and gateway to assign the device The subnet wil be filed in automaticaly as you type but please verily for accuracy Incorrect values in any of the below Fields can make it impossible for your device to communicate and can cause network disruption IP address 192 169 1 39 Subnet mask 255 255 240 0 Defauk gateway 0 0 0 0 Figure 6 Fill in IP Settings 4 Ifthe Address Unreachable window appears click Yes Installing and Running the DevicelInstaller Configuration Software Assign IP Address IP Settings Please fil in the IP address subnet and gateway to assign the device The subnet wil be filed in automatically as you type but please verify R for accuracy Incorrect values in any of the below fields can make it impossible for your device to communicate and can cause network disruption Unreachable The address you entered is not on the same subnet as this PC This PC has en auto IP PC s IP address 169 254 244 169 PC s subnet 255 255 0 0 Would you like to continue and set the IP Address Ce JC J cear Jf meo cmm o Figure 7 Address Unreachable Window 5 Click Assign to complete the process Assign IP Address Chick the Assign button to complet
12. e the IP address assignment Figure 6 Assign IP Address The assignment progress bar is displayed KRAMER SIMPLE CREATIVE TECHNOLOGY Installing and Running the DevicelInstaller Configuration Software Assignment Ch the Assign button to complete the IP address assignment Progress of task nun Figure 9 IP Address Assignment Process 2 3 1 Testing the IP Address To test the IP Address do the following 1 Select the device from the main window list 2 Click Ping from the Tools menu The Ping Device dialog box shows the IP Address of the selected device Ping Device IP Address 192 168 1 39 Status Figure 10 Ping Device Window 3 Click Ping The results will be displayed in the Status window Click Clear Status to clear the window so you can ping the device again The Ping program lets you verify that the IP address of the selected device exists on the network Installing and Running the DevicelInstaller M Configuration Software aunq IP Address 192 168 1 39 Status Reply from 192 168 1 39 bytes 60 time Oms TTL 64 Reply from 192 168 1 39 bytes 60 time ms TTL 64 Reply from 192 168 1 39 bytes 60 time 0ms TTL 64 Reply from 192 168 1 39 bytes 60 time Oms TTL 64 Figure 11 Ping Device Status 4 Click Close to close the dialog box and return to the main window Note If you do not receive Reply messages make sure the unit i
13. ling the Devicelnstaller Installer To install the DevicelInstaller M Installer do the following 1 Insert the product CD into your CD ROM drive 2 Run the DevicelInstaller M installer setup 3 Respond to the installation wizard prompts 4 Restart your system 2 2 Running the Devicelnstaller Installer Click Start on the Task Bar and select Programs Lantronix Devicelnstaller The DeviceInstaller main dialog box is displayed Figure 3 Lantronix Devicelnstaller 4 3 0 1 File Edit View Device Tools Help yp Search G Exclude amp Assign IP Em Lantronix Devices 0 device s Group IP Address Hardware Address Status aie Local Area Connection 172 17 3 7 Figure 3 Devicelnstaller Main Dialog Box To search for devices click the Search icon or select Search from the Device menu Installing and Running the DevicelInstaller M Configuration Software 2 3 Assigning an IP Address Figure 4 shows a device found on the network with the IP addresses assigned at the factory The Hardware Address is an individual permanent address assigned to a particular device on the network The Hardware Address can be found on the product label inside the unit Note Click on a device to view its attributes see Figure 4 Lantronix Devicelnstaller 4 3 0 1 File Edit View Device Tools Help 4 Search o Exclude e Assign IP e Upgrade B a Lantronix Devices 1 device s Device Details Web Configuration Telnet Config
14. mi 5 Comi06 Comi Comi08 Comi 3 Comt1 Comi11 Com112 Comi13 Comii4 Com15 Com115 Com17 Com118 Com113 Com120 C Comi21 C Com122 Comi23 C Com 24 C Comi25 C Com 26 Comi2 C Com128 Com123 C Com 30 L Comi31 C Com132 C Com133 C Com134 Com135 C Com135 Comia C Com138 C Com133 C Comi 4t Cat TORec Epi 20 KRAMER SIMPLE CREATIVE TECHNOLOGY Installing and Configuring the Com Port Redirector Software 3 Using the check boxes select the com port s to install You can select deselect multiple com ports by using the Check Range and Uncheck Range options 4 Click OK The selected com port s are displayed in the Com Port Redirector main window v CPR Manager 4 3 0 0 i pd f e ComPot Omie Tools Help AddiRemove Seve Refresh 1 Search Fer Devices Sa Exclude Com Ports Hide Com Port Lat XXCY O OX Pan 9 BD Al Com Ports 2 Com Pot IP Adde TOP Pet ComStatus Netwok Stunt 2217 Dwr Swfiec No 9 Com 1 5 WH Con 1 Inaccescble v v Cote 5 Mew WY Com 5 New gt Devico Ust Collapse ka IP Address Pot TCPPot Product ID HwAdder Network Interface Device Name Pot Name Complete n mM E Modified Figure 26 Com Ports Window Showing New Port Click Save A confirmation dialog box is displayed Click Yes The
15. perties 3 Right click the relevant Local Area Connection Properties 4 Select Properties The Local Area Connection Properties window appears 5 Select the Internet Protocol TCP IP and click Properties see Figure 1 Local Area Connection Properties General Advanced Connect using B Intel R PRO 100 VE Network Conne This connection uses the following items iv E Client for Microsoft Networks M Ji File and Printer Sharing for Microsoft Networks M fH QoS Packet Scheduler M Y Intemet Protocol TCP IP Description Transmission Control Protocol Internet Protocol The default wide area network protocol that provides communication across diverse interconnected networks Show icon in notification area when connected Notify me when this connection has limited or no connectivity Figure 1 Local Area Connection Properties Window 6 Select Use the following IP address and fill in the details as shown in Figure 2 l Connecting to the Kramer Device via the Ethernet Port 7 Click OK Internet Protocol TCP IP Properties General the appropriate IP settings Obtain an IP address automatically Use the following IP address You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for IP address 132 168 p Subnet mask 255 255 255 0 Default gateway
16. r Note Observe the following general guidelines when preparing the device server for use with Com Port Redirector Do not run the Com Port Redirector with other software that installs a virtual com port Do not run the Com Port Redirector with other Com Port Redirection software on the same PC The device server to which Com Port Redirector will connect must have an IP address The PC running Com Port Redirector must have a good network connection to the device server Do not use com ports 1 2 3 or 4 If redirecting over a Wide Area Network WAN both the PC and the device server must have a correct gateway address configured in their TCP IP settings Serial settings on the Kramer device must match the settings of the serial device Serial settings include Baud rate Parity Stop bits Flow control Interface mode RS 232 or RS 422 485 Consult your device server documentation for information about configuring these serial settings for your device server Connect Disconnect and Access Modes You must configure the way the device server accepts a connection appropriately for the device server to accept a network connection from Com Port Redirector Serial cabling between the managed serial device and the device server must be correct Consult your documentation for the pinouts of your device server For specific instructions refer to your Kramer device user manual see the Controlling via Ethernet section the
17. rt within Windows which for most purposes acts just like the selected serial port on the Kramer device CPR supports Windows XP Windows 2000 and 2003 server and Windows Vista including Terminal Services Com Port Redirector consists of the following modules e CPR Manager enables you to map com ports to device servers configure and test comports e CPR Monitor enables you to identify and troubleshoot problems You will find detailed instructions for using the modules in the Com Port Redirector online Help Overall Procedure The following procedure summarizes the steps for using Com Port Redirector 1 Install Com Port Redirector on each PC that will communicate with the device server 2 Review the general usage guidelines for the device server 3 Configure the device server and Com Port Redirector 4 Verify the connectivity between Com Port Redirector and the device server 3 1 Installing the Com Port Redirector Software To install Com Port Redirector Perform the appropriate step to start the installation f Com Port Redirector is on a CD ROM insert the CD ROM into the computer s CDROM drive and click the Redirector button If you downloaded Com Port Redirector double click the downloaded file The Lantronix CPR Welcome window is displayed 15 Installing and Configuring the Com Port Redirector Software im Lantronix CPR 4 1 0 0 Welcome to the Lantronix CPR 4 1 0 0 Setup Wizard The ins
18. s secs Figure 17 Connection Settings Window ien 13 Installing and Running the DevicelInstaller Configuration Software Figure 18 Shows the Serial Settings window Note The port settings must be set to 9600 8 1 and None fat Network Server Serial Tunnel Hostlist Channel 1 Connection Email Trigger 1 Trigger 2 Trigger 3 Configurable Pins Apply Settings Apply Defaults Firmware Version V6 5 0 3 MAC Address 00 20 4A 8C 09 A7 20 SemaSetings O O O O Channel 1 Disable Serial Port Port Settings Protocot Baud Rate 9600 Data Bits Stop Bits Pariy None v Pack Control C Enable Packing Idle Gap Time 12 msec Match 2 Byte Sequence Yes No Match Bytes Hex Send Frame Only Yes No Send Trailing Bytes None One Two Flush Mode Flush Input Buffer With Active Connect O Yes 9 No With Passive Connect Yes 9 No At Time of Disconnect Yes 9 No Flush Output Buffer With Active Connect Yes 9 No With Passive Connect O Yes 9 No At Time of Disconnect O Yes 9 No Figure 18 Serial Connection Settings Window 14 KRAMER SIMPLE CREATIVE TECHNOLOGY Installing and Configuring the Com Port Redirector Software 3 Installing and Configuring the Com Port Redirector Software The Com Port Redirector allows any PC running Windows to use ports on a Kramer device as if they were connected directly to the PC The Redirector creates a virtual COM po
19. s Ports TCP Port Product ID HW Address Network Interface Device Name Port Name uM 172 17 9 200 XPort 03 04 ER Add To Settings Change the Device nd Port Names Launch Web Interface to Device Figure 29 Assigning a Device to a Com Port 12 In the drop down menu click Add to Settings The device is added in the Host column on the Settings tab RFC2217 DTA in Tie OTR to OCO DSA always active TruPart WARHI firewall added I openini Service Host o 1 pasa EM o 8B UNS SEEN MI TN MEE EUM BEN as EUN ENS MENENENENNK 10001 Algo s are una Firewall button Hemov remove Figure 30 Device Added to Com Port 13 Optional If your PC is behind a firewall click Add Rx Port to open the port on the firewall 14 Click Save 23
20. s properly attached to the network and that the IP address assigned is valid for the particular network segment you are working with If you are not sure check with your Systems Administrator 2 4 Configuring the Ethernet Port Using Devicelnstaller You must configure the Ethernet Port so that it can communicate on a network with your serial device For example you must set the way the unit will respond to serial and network traffic how it will handle serial packets and when to start or close a connection You can configure your unit locally or remotely using the following procedures e Use the Devicelnstaller to configure the unit Some features are only available through the DevicelInstaller M Installer menus e Usea standard Web browser to access the unit s internal Web pages and configure the unit over the network see Section 2 5 This 1s the easiest and preferred method e Make sure that the Java 2 Runtime Environment Standard Edition Version 1 4 1 or higher software is installed on your PC If not download it from http java sun com 8 KRAMER SIMPLE CREATIVE TECHNOLOGY Installing and Running the DevicelInstaller M Configuration Software The unit s configuration is stored in non volatile memory and is retained without power The unit performs a reset after the configuration has been changed and stored 2 5 Configuring the Ethernet Port Using the Web Manager Page To configure the Ethernet Port via a
21. taller vall guide you through the steps required to install Lantron CPR 4 1 0 0 on pour computer WARNING This computer program ix protected by copyright law and international treaties Unauthorized duplication or distribution of this program or any portion of iE may result in severe civil ar criminal penalties and will be prosecuted to the maximum extent possible under the law L ancel Figure 19 Lantronix CPR Welcome Window 2 Click the Next button The Select Installation Folder window 1s displayed i Lantronix CPR 4 1 0 0 Select Installation Folder The installer will install Lantronis CPA 4 1 0 0 to the following Folder To install in this folder click Next To install to a different folder enter it below or click Browse Folder C Program FilesL antronisCPR SN Browse Disk Cost Cancel Back Figure 20 CPR Welcome window 16 KRAMER SIMPLE CREATIVE TECHNOLOGY Installing and Configuring the Com Port Redirector Software 3 Browse to the folder where you want to install the CPR We recommend you select the default 4 To view available disk space on your drives click the Disk Cost button 5 Click the Next button The Confirm Installation window is displayed i Lantronix CPR 4 1 0 0 Contirm Installation The installer is ready to install Lantranis CPA 4 1 0 0 on your computer Click Nest to start the installation Cancel Back Figure 21 Confirm
22. uration 8 Local Area Connection 172 17 3 7 3 E XPot re Reload Details Ei gt lt Port 03 04 firmware v5 5 0 3 Property E S Name c e DHCP Device Name Group Comments Device Family Type ID Hardware Address Firmware Version Extended Firmware Version Online Status IP Address IP Address was Obtained Subnet Mask Gateway Number of COB partitions supported Number of Ports TCP Keepalive Telnet Enabled Telnet Port Web Enabled Web Port Maximum Baud Rate Supported Firmware Upgradable Supports Configurable Pins Supports Email Triggers Supports AES Data Stream Supports 485 Supports 920K Baud Rate Supports HTTP Server Supports HTTP Setup Supports 230K Baud Rate Supports GPIO Figure 4 Device Details Value FC 3ETH Part XPort 03 04 X5 00 20 44 8C 09 47 6 5 6 5 0 3 Unreachable 172 17 8 10 Statically 255 255 0 0 0 0 0 0 6 1 0 Note The Web Configuration option 1s recommended To change the IP address 1 Select the device from the list see Figure 4 then click the Assign IP button or select Assign IP Address from the Device menu 2 Select the assignment method and click Next 4 KRAMER SIMPLE CREATIVE TECHNOLOGY Installing and Running the DevicelInstaller Configuration Software Accion IP Address Would you lke bo specily the IP eddrets or should the unit get ibs settings From a server ouk on Ehe network Obtain an IP address automatically 9 Assign a specfi
23. xclude Settings Com 5 Tests C3 All Com Ports 2 Com 5 24 gt Com 1 5 2 m 1 inat Window s Port Name Lantronix CPR Port COM5 Com 5 Window s Device Name Device CprDevice5 Com Status Closed Window s Service Name CprDrvr Network Status Disconnected Reset to Defaults Cancel Edits Buffer Writes Keep checked for better write performance Connection Timeout in seconds C Server Reconnect Timeout Reconnect 0 Reconnect Limit 0 forever C No Net Close C Listen Mode Normal port closed after discc TCP Port Add To Firewall TCP KeepAlive 7200000 Keepdlive Time msec 1000 KeepAlive Interval msec RFC2217 DTA In TruPort WARNING If the Host is on the other side of a router or a remote 1 firewall then UDP ports 30718 43282 and 43283 may need to be added to the firewall s exclusion list You may experience trouble opening this com port if these UDP ports are not excluded Also some legacy device servers respond on UDP port 43283 If you are unable to connect to a device server one possible cause is the Firewall on this machine is blocking this port Press the Add Rx Port button to add this port to the Firewall If the button caption reads Remove Hx Port then the port has already been added and can be removed by pressing this button The Firewall is turned OFF IP Addres