Ever Sinline Pro Rack 2200VA/2000W
Contents
1. EVER POWER SYSTEMS INSTRUCTION MANUAL SINLINE PRO SINLINE PRO RACK 3U EVER Sp zo o ul Grudzi skiego 30 62 020 Swarz dz Poland www ever eu upsQever eu tel 48 61 6500 400 fax 48 61 6510 927 SINLINE Pro series UPS Instruction Manual TABLE OF CONTENTS INTRODUCTION ai RO AR ZA Z ido AO 3 GENERALINFORMA TION eta Gia 3 PURPOSE OF THE POW ER SUP PLAY ahci c a a aa 3 GENERAL FEATURE SOP UPS a da a a a LN 4 ELEMENTS OF THE UPS Tower taaa a 5 Te AINE a a a a a a a a 5 PENER a a aa a ads 7 PLEMENTS OF THE UPS Rack Mode b aaa a a cade 8 PROR TANEEG RK Z O 8 RERRPANEDz NOR ER AK A ak 9 HEALTHAND SAFETY INSTRUCTION 10 PIANOLINOZ A kd R c RAGE 10 FEECTRICSAPET Y OKO POECI OOO RO 10 NSTAEEATION A ach SetlnacOSo oe O 11 UNPACKING eo o R O A O A EEEE Z 11 INSTALLATION OF THE UP e Tower nas en iaeaea Oi r aai 12 INSTALLATION OF THE UPS Rack Mod l AA Oi aea r aai 12 PHE BATTERY MODULE HE O O A 13 COMMECHIN OTe Mod le dk AO a a CE Zr a ec EN 14 Pisconnectins the module zaa ma a a oO 14 e alanine eb cts e e E OC 14 CONANT CTN THE CP Soer NEE E 16 Dpat msala OM cs Deas a a e W EE os ten dY ad 17 OMPULCINSAUALOR cesta att cas Dane cud
2. gt 45 gt 20 5 LEDs indicating the load level The right column of green LEDs indicates the percentage load level of the UPS in both the mains and battery operation mode If the top LED is lit in red and the UPS is emitting a continous sound signal this indicates that the UPS has overloaded However if the red LED is blinking and the UPS is emitting a quick intermittent signal this indicates a shorting at the back up s output lf the UPS malfunctions it switches off automatically The reason for shutdown is indicated by the combinations of LEDs lit see Description of the back up s operation 2012 03 02 www ever eu 6 SINLINE Pro series UPS Instruction Manual REAR PANEL 4 2 1 3 CO EMI 7 A 8 9 10 Fig 2 Rear panel Telecommunications filter LAN filter USB port for communication with a PC RS232 serial port for communication with a PC Stopper for the upgrade card opening internal upgrade card slot Outlet sockets two rows of 4 sockets each row secured with a separate cut out maximum current of a single socket lt 10 Circuit breakers protection of individual rows of outlet sockets After the circuit breaker is triggered the reason for shorting should be removed and the breaker pressed back in to be activated Stopper for the external battery module socket Circuit breakers protection at the mains side Switching the cut outs to
3. 100 80 50 P max min min min min Battery 2x 4x VRLA 12V 9 Ah Additional modules 4x 4x VRLA 12V 9 Ah Maximum charging time of internal batteries 9 lt 10h battery module Dimensions hxw x d UPS weight Battery module weight Outlet sockets Signalling 2 15 circuit breaker protection of outlet sockets 2 x 32A circuit breaker protection at the mains side Telecommunications filter Available LAN filter Available Communication interface RS232 USB SNMP HTTP network management card optional Note The manufacturer reserves the right to change the abovementioned parameters without prior notice Notes For normal operation of the UPS the load connected to its output should not exceed 80 of value indicated in the table Reserve power is essential to ensure continuous operation of connected devices in case of momentary rushes in load current Continued exposure of the UPS to the temperature of the surrounding exceeding 25 C will shorten the life of batteries If the altitude above sea level increases beyond the provided limit the permitted load power of the batter back up decreases The User may modify the switching thresholds Factory setting is provided in parentheses After discharging the UPS with power 80 Pmax charging the battery to 90 capacity 2012 03 02 www ever eu 3 1 SINLINE Pro series UPS Instruction Manual TECHNICAL PARAMETERS Rack Model SINLINE PRO SINLINE PRO SINLINE
4. Instruction Manual Fig 7 Installation of the management card CONNECTING THE UPS The power cord that comes with the UPS has no plug and it needs to be connected to the mains by fixing the tips of individual wires to the connector All wires are marked appropriately L live wire brown N neutral wire blue PE earthing yellow green Wire diameter 2 5 sq mm The arrangement of the installation must enable disconnecting the section where the UPS is connected from the mains e g by turning overcurrent switches WARNING Connecting of the UPS to the mains should be performed only by qualified and authorised personnel WARNING The UPS is disconnected from the mains only when the power cord is removed from its socket 2012 03 02 www ever eu 16 SINLINE Pro series UPS Instruction Manual lt is recommended to use the safety circuits of the building as one of the protection measures Protection parameters of the buildings installations should be adjusted accordingly to the type and size of load connected to the installation Differing characteristics of protections of installations in the building and the UPS may in extreme cases lead to quicker responses of the former Input installation Fig 8 presents the ways of correct connection of the UPS to different types of mains TN S or TN C S that vary with regard to the manner of earthing POWER SUPPLY POWER SUPPLY OUTPUT
5. they must be connected with a cable with RJ45 terminators The existing ETHERNET UTP line should be connected to the other outlet socket of the filter The filter is symmetrical so it does not matter to which of the two sockets the ETHERNET UTP line is connected 2012 03 02 www ever eu 29 SINLINE Pro series UPS Instruction Manual STORAGE MAINTENANCE AND TRANSPORT The UPS should be stored in a cool and dry place in operating position with batteries fully charged e In temperatures between 0 C and 30 C the battery should be charged every 6 months e In temperatures between 30 C and 45 C the battery should be charged every 3 months The UPS should be transported in the original packaging and in conditions conforming to the product s specification see Technical parameters If the packaging is missing or a non original or incomplete packaging is used EVER Sp Z 0 0 Shall not be liable for any mechanical damages that occur in transport DISPOSAL Appropriate disposal of used up electric and electronic equipment helps to avoid consequences resulting from the presence of dangerous materials as well as inappropriate disposal and processing of such equipment which may be hazardous to human life and the environment Act dated 29 July 2005 on used up electric and electronic equipment Article 22 1 items 1 and 2 x O According to the applicable EU regulations a crossed rubbish bin symbol means that when a produc
6. 18 kg 33 55 kg jui 18 32 kg storage and operation of the device should take place in conditions conforming to gt 55 kg its specification ELECTRIC SAFETY Never work alone in conditions that may be hazardous to health and or life Even a momentary shorting of a strong current may lead to severe burns Prior to connecting the device to the mains inspect the condition of power cords plugs and sockets as well as the condition of the device itself To minimize the risk of electric shock in cases when there is no way of verifying the earthing the device should be disconnected from the mains before installation or connection of other equipment to the back up reconnect the power cord only after all connections are made To avoid the risk of electric shock when connecting and disconnecting signal cables and touching two surfaces with differing electric potential if possible use only one hand The device must be plugged in to a three lead installation two poles and earthing failure to meet this requirement may result in electric shock The installation must enable a complete disconnection of the UPS from the mains e g by switching the S type fuse The device receiving the current must be connected with an appropriate circuit protection manual cut out or circuit breaker The device has an earthing lead that carries away the leakage current from the receivers e g computer equipment the total leakage curren
7. PRO SINLINE PRO model 2200 model 3000 model 4000 model 5000 2000 W 2800 W 3000 W 3250 W Working environment Office or industrial rooms with low level of pollution Operating temperature 10 35 C Storage temperature 0 45 Relative humidity for operation 20 80 without condensation Relative humidity for storage 20 95 without condensation Altitude above sea level up to 1000 m Maximum length of outgoing cables lt 10m MAINS OPERATION MODE Input voltage 150 280 V 7160 265 V 2 Frequency of input voliage 45 55 Hz 1 Hz Range of output voliage 172 280 V 7184 265V 2 Switching thresholds Mains UPS 150 170 V 160 V 255 280 V 265 V 2 9 Shape of output voltage Filtering of output voltage Time to switch to UPS Output voltage effective value Shape of output voltage Switching thresholds UPS mains 155 175 V 165 V 250 275 V 260 V 2 Frequency of output voltage Filtering of output voltage Shorting safeguard Overload protection Time to switch back to mains operation Support time with internal batteries only 4 5 6 5 12 100 80 50 P max min min min min Support time with battery module installed 60 65 130 34 39 88 30 36 80 28 32 75 100 80 50 P max min min min min Battery 2x 4x VRLA 12V 9 Ah Additional modules 4x 4x VRLA 12V 9 Ah Maximum charging time of internal batteries Maximum charging time of internal batteries Dimensions h x w x d UPS weight B
8. and install the appropriate driver In the case of Windows Vista the operating system will not initiate automatic installation of the drivers from the hard drive After connecting the USB cable to the computer you will need to open the control panel from the Start Menu and select system properties On the device tree displayed find the USB bus branch in most cases it will be already expanded and select the ups Update the device s driver from i s Properties window by right clicking it in the list and following the instructions onscreen As the driver s location you should indicate the PowerSoft installation folder usually C Program Files PowerSoft To uninstall PowerSoft select the Uninstall PowerSoft option in Start Menu You can also uninstall PowerSoft from the Add and remove programs menu in the control panel 2012 03 02 www ever eu 24 SINLINE Pro series UPS Instruction Manual Installation on computers with Linux Unix The binary version of the application for Linux Unix systems is provided in the following formats CentOS RedHat Suse Linux Fedora Core For the CentOS RedHat Suse Linux and Fedora Core systems the software is provided in the form of a RPM package The software can be installed by using any package manage available for the system installed If you are using the command line the software is installed by entering the following command rpm ivh PowerSoftpersonal x x Xx 13686 rpm Users working
9. s power cord is connected is appropriate then after approximately 5 seconds the UPS switches to the mains operation mode and lights the green operation mode LED If the mains voltage is incorrect too low or too high voltage or frequency exceeding the operation range the UPS switches to the back up operation mode and lights the red operation mode LED In the mains operation mode the UPS outlet provides mains voltage that was filtered and optionally raised by the AVR system BACK UP BATTERY OPERATION MODE In the back up operation mode the true sine wave voltage output is generated by the battery until the mains voltage returns the battery is discharged or an emergency situation takes place When operating in the back up mode if the batteries are discharged or the appropriate command from the control software is given the UPS may switch to the battery stand by mode STAND BY MODE The UPS switches to STAND BY mode when the batteries are completely discharged or when it receives an appopriate command from the control software The UPS will wait for the mains voltage of correct parameters to come back in order to return to the mains operation mode and charges the batteries if they were discharged EMERGENCY MODE In this mode the UPS cuts the power power from its outlets and signals all malfunctions and their origins Emergency mode is signalled with a sound and by blinking the red LED in the load column as well as appropriate combinati
10. software e HTTP server enables inspection and modification of the UPS parameters via an Internet browser e Telnet server control a Telnet network terminal More information on the network adapter can be found in its instruction manual CONFIGURING THE UPS PARAMETERS PowerSoft Plus allows the user to change certain parameters of the UPS To enable this the UPS must be connected to the computer with the cable provided by the manufacturer A list of these parameters together with available settings is presented in the tables below Table 2 FACTORY PARAMETER FUNCTION SETTING USER CHOICE DESCRIPTION Acoustic signalling On off Only for the battery operation mode Time between system shutdown and the Delay before standby mode 0 1000 sec UPS switching to standby mode Table 3 THRESHOLD SWITCHING VOLTAGE ooo Default setting BAT MAINS AVR 155 175 165 V MAINS AVR gt BAT 150 170 V 160 V MAINS AVR gt MAINS 200 210 V 205 V MAINS MAINS AVR 195 205 V 200 V MAINS BAT 250 280 V 265 V BAT MAINS 245 275 V 260 V BAT battery operation mode MAINS mains operation mode MAINS AVR mains operation mode with AVR system engaged 2012 03 02 www ever eu 27 SINLINE Pro series UPS Instruction Manual ADDITIONAL REMARKS CAUTION Product for commercial and industrial applications in secondary environment Applying additional preventive measures or lim
11. with the PowerSoft must have root privileges to install the software and use it After installation the application may be found in the usr local PowerSoft directory To uninstall the application enter the following command rpm ev POwWeroOlepersonalax x x Debian For Debian systems the software is provided in the form of a DEB package The software is installed via the following command dpkg install PowerSoftpersonal x x x deb To uninstall the application enter the following command dpkg remove PowerSoft FreeBSD For FreeBSD systems the software is provided in the form of the default package format designed for FreeBSD systems The software is installed via the following command PRO add POWeroOLL per sonal xXx TOZ To uninstall the application enter the following command PKG das POWersore 2012 03 02 www ever eu 25 SINLINE Pro series UPS Instruction Manual WARNING FreeBSD systems do not support communication with the UPS via the USB cable Starting the software When the installation is complete the system service is started automatically while the control panel application can be found at usr local PowerSoft Please note that for the Polish diacritics to be correctly displayed the system locale should be Polish Software Updates Windows systems The software installer for Windows systems has a built in automatic updater PowerSoft can regularly check for new software versions and notif
12. 5 gt 30 gt 60 gt 85 2012 03 02 www ever eu 8 SINLINE Pro series UPS Instruction Manual mains and battery operation mode If the last LED is lit in red and the UPS is emitting a continous sound signal this indicates that the UPS has overloaded However if the red LED is blinking and the UPS is emitting a quick intermittent signal this indicates a shorting at the back up s output lf the UPS malfunctions it switches off automatically The reason for shutdown is indicated by the combinations of LEDs lit see Description of the back up s operation REAR PANEL 1 1801 Fig 4 Rear panel 1 Telecommunications filter 2 LAN filter 3 Outlet sockets two rows of 4 sockets each row secured with a separate cut out maximum current of a single socket lt 10A 4 USB port for communication with a PC 5 RS232 serial port for communication with a PC 6 Circuit breakers protection of individual rows of outlet sockets After the circuit breaker is triggered the reason for shorting should be removed and the breaker pressed back in to be activated Stopper for the external battery module socket Fan 9 Stopper for the upgrade card opening internal upgrade card slot 0 10 Mains power cord 2012 03 02 www ever eu 9 SINLINE Pro series UPS Instruction Manual HEALTH AND SAFETY INSTRUCTIONS HANDLING exercise utmost caution when handling the device do not handle heavy equipment by yourself lt
13. EE E E 32 INFORMATION REGARDING REGULATIONS AND WARRANTY 33 DECLARA TION OPF CONFORMITY wodzowi a Nas 33 WARRANTY RA NO a Oi NS 33 2012 03 02 www ever eu 2 SINLINE Pro series UPS Instruction Manual INTRODUCTION Thank you for purchasing the EVER SINLINE PRO UPS It belongs to the latest series of state of the art power supply devices designed to work with servers computer networks as well as workstations When operating in the battery mode the UPSs of this series generate true sine wave voltage at their output thanks to the Clear Digital Sinus CDS system and offer the feature of remote control of operating parameters via RS232 serial port or USB and optionally via the EVER control network adapter Telnet SNMP HTTP SINLINE PRO series EVER UPS was designed so as to meet all your expectations for protection against power loss The UPS was manufactured in Poland and its structure conforms with requirements of the CE symbol GENERAL INFORMATION PURPOSE OF THE POWER SUPPLY SINLINE PRO series UPS are LINE INTERACTIVE VI class devices designed for work with equipment powered by monophase 230V mains In back up operation mode they generate true sine wave at their output It enables a definite improvement of energy compatibility of the UPS and connected receivers SINLINE PRO UPS do not switch off automatically even when there are no devices connected to the outle
14. Fig 8 Input installation of the UPS Output installation Even though the input side allows both types of terminals the output installation arranged inconsistently with this instruction may damage the UPS The diagram of correctly arranged output connections is presented in Fig 9 WARNING The output side of the back up only allows the TN S mains configuration 2012 03 02 www ever eu 17 SINLINE Pro series UPS Instruction Manual POWER SUPPLY ZL Z aia gt gt gt A o o N A HM N e Z 2 PaA i a a INCORRECT Fig 9 Output installation of the UPS The arrangement of terminals of output sockets of the UPS is presented on Fig 10 Fig 10 Arrangement of terminals of output sockets After unpacking the device should be placed in the chosen location power supply to the connection should be cut off and the UPS connected to the mains After the back up is correctly connected to the mains the power supply may be switched back on Make sure the S type circuit breakers located on the UPS are switched to the ON position 2012 03 02 www ever eu 1 8 SINLINE Pro series UPS Instruction Manual FIRST START At the first start the UPS may require to be left connected to the mains in order to allow the internal batteries to charge The power switch on the front panel should be turned to the ON position Charging time of batteries is presented i
15. STALLATION AND CONFIGURATION OF THE POWERSOFT PERSONAL SOFTWARE Installation on computers with Windows Prior to beginning the installation of PowerSott e Uninstall the current version of PowerSoft or any other control software in situations where the user is changing the UPS protecting the computer e lf the installed UPS communicates with the PC via a USB cable this cable should be disconnected from the computer The software installer will prompt the user to connect the communication cable at the appropriate time To install PowerSoft on a computer with Windows the list of operating systems compatible with the application is available at www ever eu just run the software installer and follow the instructions onscreen During the installation you will be asked to select the model of the UPS connected to the computer on which the software is being installed This setting may also be changed when the application is running In the case of a UPS connected to the computer via a USB cable when the software installation is complete the PowerSoft installer will ask the user to connect the USB cable to the computer The system will announce that a new device has been found and will propose to install the drivers Select the option to install the drivers from a chosen location and on the next screen indicate the installation folder of the PowerSoft software usually C Program Files PowerSoft to be searched Next the operating system will locate
16. are LINE INTERACTIVE VI class devices synchronising with the mains voltage By design the UPS tolerates mains voltage variations in the range of 160 264V basic range or 150 280V enhanced range as well as frequency variations of 5Hz with relation to the nominal frequency of 50Hz When connected to a power generator the frequency variations change over time and are strictly dependent on changes in load levels If the frequency variations of a power generator s voltage exceed the allowed tolerance range the UPS will consider such frequency to be incorect and switch to battery operation mode USING THE TELECOMMUNICATIONS FILTER In order to protect the telephone line and connected devices such as modems or telephones the SINLINE PRO UPSs are equipped with an anti overvoltage filter which safeguards the devices connected against overvoltages in the telephone line lf the filter is to safeguard the devices correctly they must be connected with a cable with RJ11 or RJ12 terminators The existing telephone line should be connected to the other outlet socket of the filter The filter is symmetrical so it does not matter to which of the two sockets the telephone line is connected USING THE LAN FILTER In order to protect the ETHERNET UTP line and connected devices the SINLINE PRO UPSs are equipped with an anti overvoltage filter which safeguards the devices connected against overvoltages If the filter is to safeguard the devices correctly
17. attery module weight Outlet sockets Signalling Cut out 2 x 15A circuit breaker protection of outlet sockets 2 x 32A circuit breaker protection at the mains side Telecommunications filter Available LAN filter Available Communication interface RS232 USB SNMP HTTP network management card optional Note The manufacturer reserves the right to change the abovementioned parameters without prior notice Notes For normal operation of the UPS the load connected to its output should not exceed 80 of value indicated the table Reserve power is essential to ensure continuous operation of connected devices in case of momentary rushes in load current Continued exposure of the UPS to the temperature of the surrounding exceeding 25 C will shorten the life of batteries wo If the altitude above sea level increases beyond the provided limit the permitted load power of the batter back up decreases The User may modify the switching thresholds ol Factory setting is provided in parentheses R After discharging the UPS with power 80 charging the battery to 90 capacity 2012 03 02 www ever eu 3 2 SINLINE Pro series UPS Instruction Manual INFORMATION REGARDING REGULATIONS AND WARRANTY DECLARATION OF CONFORMITY The UPS was manufactured in Poland and its structure conforms to appropriate subject matter standards WARRANTY A separate document attached to the product con
18. e used in rooms whose dustiness temperature and moisture levels conform with the device s specification To ensure correct operation of the back up appropriate cooling conditions for the device must be provided For this reason the ventilation Openings on the back up s case must be uncovered and the distance between the back up and other objects should be at least 10 cm The back up is designed for installation in a cabinet rack In order to facilitate installation in cabinets racks of various depth the device is equipped with adjustable rails which enable installation in racks of varying depth 2012 03 02 www ever eu 1 2 SINLINE Pro series UPS Instruction Manual To install the UPS take the following steps 1 Install the moving handles in the back section of the cabinet 2 Supporting the back ups base with your hand slide UPS onto the previously installed handles 3 Screw the front fixed handles of the UPS to the rack s frame Fixed handle Moving handle Moving handle Fixed handle Fig 5 SINLINE PRO 19 RACK 3U Top View WARNING The device must not be installed in the proximity of flammable materials THE BATTERY MODULE SINLINE PRO UPS have the option of connecting an additional battery module For this the special connector located on the rear panel is used Connecting a battery module extends the time of battery operation mode The battery module is protected by an additional cut out located ins
19. e document must meet all formal requirements e g date of sale dealer stamp 2012 03 02 www ever eu 3 3
20. ga cea cise R cod ian tad RO ER EJ OE ad 17 IRS Ona dE N nen err en Tn tree era hye en 4 Sener ner nena 6 19 DESCRIPTION OF IL BEBACNUPSOPERATIONA Acha w 19 GENERALINFORMA LION a 19 MAINSOPFERATION MODE e dd E hw 21 BACK UP BATTERY OPERATION MODE ada atb 21 STANDBY MODE sersan dioda 21 EMERGENCY aaa a GRE 21 SAEEGUARDOR i 22 COMMUNIC ATION VIA RS2 32 OR US Ea 23 INSTALLATION AND CONFIGURATION OF THE POWERSOFT PERSONAL SOFTWARE 24 Installation on Computers with WiIndOWS iones neinn R EO OBO 24 Installation on computers woda aid Ao ok 23 ane Updates dob AERO b GA o tao OBO 26 EVER SNMP HTTP NETWORK MANAGEMENT CARD 27 CONFIGERINGTHEUPSPARAMETERO zadko NOA hi 27 ADDIIONALEREMAREN CG SARZE zoo ad 28 UPS AND POWER GENEICA TOR 0 a Ad 29 USING THE TELECOMMUNICATIONS BIL TER Ac 29 USING TRELANEILTER acc O AEO Oc 29 STORAGE MAINTENANCE AND 30 DISPOSA Dorin AO air adi Wad Ea 30 TECHNICAL PARAMETERS Tower Model ee eeeoooeoooooo ooo EEO A 31 TECHNICAL PARAMETERS Rack Model aereoa aa E E A E
21. ide the module Replacement of cut outs should be conducted only by a qualified representative of the technical support WARNING The given model of UPS may only be enhanced with battery modules recommended by the manufacturer see Technical parameters 2012 03 02 www ever eu 1 3 SINLINE Pro series UPS Instruction Manual Connecting the module 1 Turn the UPS off with the power switch on the front panel and switch the circuit breakers to the OFF position Remove the stopper covering the connector rear panel Connect the battery module to the UPS switch the circuit breakers to the ON position and then turn the UPS on with the power switch on the front panel 5 Configure the number of battery modules in the PowerSoft software for SINLINE PRO UPSs the maximum number is 1 6 After the batteries are charged the UPS is ready for operation WARNING During the first charging of batteries the UPS must not be turned off with the power switch located on the front panel This may lead to errors in the UPS calibration Disconnecting the module 1 Turn the UPS off with the power switch on the front panel and switch the circuit breakers to the OFF position Disconnect the battery module from the UPS Secure the connector by replacing the protective stopper Switch the circuit breakers to the ON position and then turn the UPS on with the power switch on the front panel 5 Configure the number of battery mod
22. iters in the installation may be required in order to prevent the emission of disruptions WARNING No service elements located inside the UPS are to be modified by the end user e Damaging the warranty seal shall void the warranty for the given device e Any repairs should be conducted only by qualified technical support staff e The UPS may not perform as expected if the powered equipment draws high impulse power In practice this means that even though mean power of the protected equipment does not exceed the power range accepted by the UPS the equipment will cause the UPS to shut down This happens because the protected equipment temporarily draws power that significantly exceeds the nominal power of the UPS which causes an overload detection and consequently a shutdown This situation may occur in the case of u Television sets and monitors as they are switched on the picture tube is degaussed which temporarily requires a lot of power u Laser printers drum warming cycle x Other products with similar operating features Therefore if a UPS is to be used with equipment other than computers its compatibility with equipment used must be verified In order to do this all devices should be connected to the UPS and its operation should be observed in all modes i e start up shutdown stand by etc 2012 03 02 WWW ever eu 28 SINLINE Pro series UPS Instruction Manual UPS AND POWER GENERATORS SINLINE PRO UPSs
23. kaging The packaging should be retained e g for later transport to a service centre 2012 03 02 www ever eu 1 1 SINLINE Pro series UPS Instruction Manual Check the contents of the packaging The packaging should contain e the UPS e a CD ROM with the PowerSoft software and complete instruction manual e communication cable to connect the back up to a computer via RS232 e communication cable to connect the back up to a computer via USB e 4 outlet power cords e warranty card e 2 moving handles for cabinet installation Rack Model INSTALLATION OF THE UPS Tower Model When choosing the installation location you must take the device s weight into account The back up should only be used in rooms whose dustiness temperature and moisture levels conform with the device s specification To ensure correct operation of the back up appropriate cooling conditions for the device must be provided For this reason the ventilation openings on the back up s case must be uncovered and the distance between the back up and other objects should be at least 10 cm WARNING The device must not be installed in the proximity of flammable materials INSTALLATION OF THE UPS Rack Model When choosing the installation location you must take the device s weight into account The strength of the supporting cabinet rack is the most essential Therefore it is recommended to install the UPS as low as possible The back up should only b
24. n the technical parameters table Afterwards the user may continue with the installation procedure Take the following steps e Turn the UPS off with the power switch on the front panel only if it was turned on e connect the devices that require buffer power supply e g computer and monitor to the outlet sockets on the UPS e connect the UPS to the computer use one of the two available connections RS232 or USB e turn onthe UPS with the switch on the front panel e turn on the devices connected to the UPS e install the monitoring software on the control computer see chapter Installation of the PowerSoft software With all of the above actions complete the UPS is ready for operation WARNING The UPS reach their full capacity after approximately a month of mains operating mode DESCRIPTION OF THE BACK UP S OPERATION GENERAL INFORMATION The SINLINE PRO UPS is a state of the art electronic device constituting an autonomous source of true sine wave voltage of 230V This device belongs to the group of LINE INTERACTIVE VI class UPSs which includes UPS that synchronise with the mains The UPS is equipped with the CLEAR DIGITAL SINUS CDS system which generates a precisely stabilised output voltage in the shape of sinusoid which enables supplying power to a wide range of equipment that do not tolerate quasi sine wave voltages This system increases the reliability of the device and guarantees stable operation of
25. ng of the mains voltage e elecommunication and LAN filter e 5232 serial ports and a USB port for communication with a e Upgrade card slot e g management e Option of connecting an additional battery module e Archiving and storage of data pertaining to the back up s operation e Calculation of currently available time of battery operation mode e PowerSoft software to monitor the operating parameters of the back up and shut down the system automatically 2012 03 02 www ever eu 4 SINLINE Pro series UPS Instruction Manual ELEMENTS OF THE UPS Tower Model FRONT PANEL Fig 1 Front panel 1 Power switch 2 Two colour LED indicating the operating mode a Mains Operation Mode constant green light blinking green LED indicates the need for a technical periodic review by EVER s Technical Service signaling doesn t mean that fault occurs the UPS will continue to work properly b Battery operation mode constant red light blinking red LED indicates that a flat battery must be changed 3 LED indicating whether the AVR Automatic Voltage Regulation system is activated 4 LEDs indicating the available battery capacity 2012 03 02 www ever eu SINLINE Pro series UPS Instruction Manual Available battery capacity maximum battery capacity obtainable at the current UPS load The left column of green LEDs indicates the charge gt 95 level of batteries gt 80
26. ons of lit LEDs in the battery charge column see Table 1 2012 03 02 www ever eu 2 1 SINLINE Pro series UPS Instruction Manual The UPS remains in emergency mode until switched off by the user or until the batteries are completely discharged Table 1 ERROR TABLE Type of error UPS connected incorrectly Internal errors a combination of lit LEDs indicates various errors SAFEGUARDS Aqainst overloads An overload is signalled by constant shining of the last LED red in the load indication column and a continuous sound signal lf the UPS is operating in back up mode and the overload lasts longer than 10 seconds the UPS will switch to emergency operation mode Outlet sockets are disconnected from the power supply Against shorting In the mains operation mode the safeguard against shorting is provided by the cut outs located in the rear section of the UPS In the battery operation mode the electronic shorting safeguard reduces the short circuit current to a safe level by lowering the output voltage When the shorting occurs in the back up operation mode it is signalled by the UPS with a quick blinking of the last LED red in the load indication column and a quick intermittent sound signal If the shorting lasts longer than 1 second the UPS will switch to the emergency operation mode 2012 03 02 www ever eu 22 SINLINE Pro series UPS Instruction Manual Against overvoltage The UPS is eq
27. s modes of communication between the UPS and the computer via a communication port or a special slot for The EVER management card HTTP telnet SNMP The UPS conducts precise measurements of its basic parameters such as battery voltage mains input voltage output voltage of the UPS power of the load connected temperature and advanced parameters measurement of available battery capacity remaining time of battery operation mode with the current load This UPS utilises an innovative charging method reserved only for the most advanced UPS CBC COOL BATTERY CHARGING which utilises the elements of an internal inverter During the mains operation mode it charges the batteries and in the back up operation mode it converts the internal energy of the battery into the alternating current to power the protected devices 2012 03 02 www ever eu 20 SINLINE Pro series UPS Instruction Manual MAINS OPERATION MODE Connecting the UPS to the mains does not cause current to appear at the back up s output UPS batteries are not charged either The UPS is turned upon pressing the power switch on the front panel Switching on is accompanied by the operation mode LED lighting in red and then after approximately 3 seconds a sound signal Subsequently all LEDs on the front panel light up so their correct operation can be verified autotest Next the UPS will attempt synchronisation with the mains If the mains voltage of the socket where the back up
28. stitutes the warranty The document must meet all formal requirements e g the following fields must be populated serial number model type date of sale and dealer stamp The manufacturer made all efforts to ensure that products offered are free of material and workmanship defects throughout the term specified in the warranty document The company s liability under the warranty shall be limited to repairs or replacement of products with such defects The manufacturer shall make the decision as to how the defect is removed The warranty shall not cover devices with mechanical damages that occurred as a result of negligence of incorrect use nor devices subjected to any modifications made by the user Apart from the arrangements included in the warranty card EVER Sp z o o shall not grant any guarantee or warranty including warranty of merchantability or fitness for particular purpose Apart from the arrangements included in the warranty card EVER Sp z o o shall not be liable for direct indirect specific incidental or consequential losses incurred in the course of using the UPS even in cases when the buyer was warned about such losses being a possibility The company shall not be liable for any costs such as loss of profit or revenue cost of equipment costs of equipment use costs of software data replacement products claims of third parties or other costs A separate document attached to the product constitutes the warranty Th
29. t sockets so they may even power devices with extremely low power consumption Load power of this UPS is limited only at the upper extreme and the overload status is Communicated visually accoustically and via the PC software monitoring the device Unlike quasi sine wave UPS the SINLINE PRO series may power devices with induction motors WARNING SINLINE PRO UPS were not designed to work with life and or health support medical equipment 2012 03 02 www ever eu 3 SINLINE Pro series UPS Instruction Manual GENERAL FEATURES OF THE UPS e True sine output wave generated in battery operating mode e DPC Digital Power Control digital control of operating parameters of the back up such as shape of the output voltage frequency of the output voltage battery charge level battery voltage and current measurement of battery charge displayed on the front panel battery life temperature of essential parts of the UPS e Digital monitoring of external parameters such as value of the mains voltage value of the mains current frequency of the mains voltage value of active power and apparent power drawn from the mains mains power factor value of the active power and apparent power connected to the back up s output output power factor presence of the battery module connected to the UPS e AVR Automatic Voltage Regulation automatic mains voltage regulation system e Filteri
30. t is no longer used it should be disposed of at a special waste pickup site This concerns the device itself as well as other accessories marked with this symbol Do not dispose of those products together with unsorted household waste Method of safe removal of the batteries from the appliance The batteries should be removed from the appliance by an authorised service outlet or by a duly authorised electrician 2012 03 02 www ever eu 30 SINLINE Pro series UPS Instruction Manual TECHNICAL PARAMETERS Tower Model PARAMETERS SINLINE PRO SINLINE PRO SINLINE PRO SINLINE PRO 2000 W 2800 W 3000 W 3250 W Office or industrial rooms with low level of pollution 20 95 without condensation Maximum length of outgoing cables Input voltage Frequency of input voltage Range of output voltage Switching thresholds Mains UPS 150 170 V 160 V 255 280 V 265 V 2 Shape of output voltage Filtering of output voltage Time to switch to UPS Output voltage effective value Shape of output voltage Switching thresholds UPS mains 155 175 V 165 V 250 275 V 260 V 2 Frequency of output voltage Filtering of output voltage Shorting safeguard Overload protection Time to switch back to mains operation Support time with internal batteries only 4 5 6 5 12 100 80 50 P max min min min min Support time with battery module installed 60 65 130 34 39 88 30 36 80 28 32 75
31. t must not exceed 3 5MA 2012 03 02 www ever eu 10 SINLINE Pro series UPS Instruction Manual Users are forbidden to carry out any maintenance activities as they may lead to injury or death Any repairs and replacement of batteries should be conducted only by qualified technical support staff WARNING The UPS is disconnected from the mains only when the power cord is removed from its socket WARNING Since the device is equipped with internal power source batteries the output may provide hazardous voltage even though the device itself is not connected to the mains WARNING SINLINE PRO UPS were not designed to work with life and or health support medical equipment INSTALLATION WARNING Prior to the installation of the UPS it is crucial to familiarise yourself with the health amp safety measures provided in the previous chapter UNPACKING Please inspect the UPS upon receipt Although the product is packed very carefully it could have sustained damage from shock during transport Should you find any damages please inform the carrier or dealer immediately prepare a damage protocol and photograph the damaged parts WARNING device is delivered with its battery connected The UPS is placed inside a wooden box which enables safe transport also by forklift To unpack the UPS you must remove the screws in the walls of the box This will enable the disassembly of individual elements of the pac
32. the OFF position disconnects the UPS from the mains 10 Mains power cord 2012 03 02 www ever eu SINLINE Pro series UPS Instruction Manual ELEMENTS OF THE UPS Rack Model FRONT PANEL Fig 3 Front panel 1 Circuit breakers protection at the mains side Switching the cut outs to the OFF position disconnects the UPS from the mains 2 Power switch 3 Two colour LED indicating the operating mode a Mains operation mode constant green light blinking green LED indicates the need for a technical periodic review by EVER s Technical Service signaling doesn t mean that fault occurs the UPS will continue to work properly b Battery operation mode constant red light blinking red LED indicates that a flat battery must be changed 4 LED indicating whether the AVR Automatic Voltage Regulation system is active 5 LEDs indicating the available battery capacity Available battery capacity maximum battery capacity obtainable at the current UPS load The upper line of green LEDs indicates the gt 20 gt 45 gt 80 gt 95 charge level of batteries 6 LEDs indicating the load level O O O The lower line of green LEDs indicates the percentage load level of the UPS in both the gt
33. the UPS 2012 03 02 www ever eu 1 9 SINLINE Pro series UPS Instruction Manual With the help of the Automatic Voltage Regulation AVR system the UPS instantly corrects slight drops in mains voltage to provide the receivers with appropriate power supply conditions without tapping into the energy reserves stored in the batteries The back up also uses the system of advanced DIGITAL POWER CONTROL DPC which precisely shapes the oscillation of the output voltage to obtain a clear sinus In the mains operating mode the system filters the mains voltage to remove the noise and distortions that may be dangerous for the receivers The dedicated DPC system monitors the operation of the UPS it has a precise and very quick reacting system of detecting overloads and outlet shorting in the backup operation mode In mains operation mode the shorting safeguard is provided by cut outs and overloads are signalled both visually and acoustically When the UPS is started in the back up operation mode a special soft start mode is used in order to launch with high loads that draw high starting current e g laser printers Moreover the DPC system enables long operation in battery mode by allowing connection of an additional battery module and control of internal temperature by means of an active cooling system which is activated as necessary This manner of switching on the cooling reduces the amount of noise generated by the UPS The DPC system offers variou
34. uipped with anti overvoltage safeguard at the input which protects the circuits of receivers and the internal circuits of the UPS against high energy current rushes caused by atmospheric phenomena and power grid disruptions Against incorrect connection Incorrect connection of the UPS causes it to switch to emergency operation mode the moment it is switched on This is signalled by slow blinking of the last LED red in the load indication column and an intermittent sound signal mirroring the rate of blinking In addition the layout of lit LEDs in the battery charge level column indicates the type of error see the Error Codes table COMMUNICATION BETWEEN THE UPS AND A COMPUTER COMMUNICATION VIA RS232 OR USB SINLINE PRO series UPS come with enhanced control features The UPS is delivered with a built in RS232 and USB communication port and the PowerSoft software package To ensure correct cooperation the UPS must be connected to the computer with the provided cable WARNING The communication connection between the UPS and the computer should be made only if the user intends to use the control software If the software is not installed while the connection is made then the RS232 or USB port may receive random conditions PNP or others which may lead to incorrect operation of the UPS A WARNING Only one type of connection may be used at any given time 2012 03 02 www ever eu 23 SINLINE Pro series UPS Instruction Manual IN
35. ules in the PowerSoft software in the case of no modules set the parameter to 0 6 After the batteries are charged the UPS is ready for operation EVER Management CARD The EVER management card is an optional component that may be installed by the user Installing the card renders the communication via RS232 and USB impossible 2012 03 02 www ever eu 14 SINLINE Pro series UPS Instruction Manual Installing the management card Tower Model 1 Turn the UPS off with the power switch on the front panel and disconnect it from the mains by removing the power cord plug from the mains socket 2 Remove the screws holding the cover of the card slot and remove the cover Fig 6a 3 Connect the cable located in the opening to the card Fig 6b 4 Slide the card into the slot Fig 6c 5 Replace the screws fixing the card to the rear panel Fig 6d d Fig 6 Installation of the management card Installing the management card Rack Model 1 Turn the UPS off with the power switch on the front panel and disconnect it from the mains by removing the power cord plug from the mains socket 2 Remove the screws holding the cover of the card slot and remove the cover Fig 7a 3 Connect the cable located in the opening to the card Fig 7b 4 Slide the card into the slot Fig 7 5 Replace the screws fixing the card to the rear panel Fig 7d 2012 03 02 www ever eu 15 SINLINE Pro series UPS
36. y the user when updates are available By default the software checks for updates after the user logs in This setting can be changed under the Update configuration tab in the system s programme menu Linux Unix systems In the case of Linux Unix systems PowerSoft can be updated by downloading the new package from www ever eu In the case of CentOS RedHat Suse Linux and Fedora Core PowerSoft can be updated by entering the following command tpm POWELSOLELI CCX sx aX In the case of Debian and FreeBSD systems we recommend uninstalling the old version and then installing the new version of the software Commands which enable these operations are described in the instruction manual available at www ever eu 2012 03 02 www ever eu 26 SINLINE Pro series UPS Instruction Manual EVER SNMP HTTP NETWORK MANAGEMENT CARD Optionally the UPS can be upgraded with the EVER SNMP HTTP network management card It is a device that integrates the UPS with an Ethernet network The network adapter is located in a special slot located on the rear panel of the UPS With the network adapter installed the user can control the UPS from any computer connected to the network This solution is most frequently used in cases of central power supply or when the power supply system needs to be controlled remotely The network adapter has the following services implemented e SNMP agent enables control of the power supply system via a SNMP manager