Home
Zalman RESERATOR XT
Contents
1. and its components may change without prior notice to improve performance
2. components may change without prior notice to improve performance e The specifications of this product and its components may change without prior notice to improve performance 5 3 Reserator XT s Coolant Circulation 1 The purpose of connecting the Jump Cable of the Power Supply s Main Connector 20P 24P is to receive direct current 12V needed for the test run and leakage inspection 2 For smooth initial degassing connect one end of the Degassing Tube to the OUT terminal of the Reserator and repeatedly press the opposite Quick Coupling end with the finger to discharge the internal air Now remove this end of the Degassing Tube from the OUT terminal 3 Connect the other end of the Degassing Tube to the IN terminal and remove the internal air in the method described above and connect the opposite Quick Coupling end to the OUT terminal 4 Remove the Power Supply s Main Connector 20P 24P and the 4 Pin CPU Sub Connector from the motherboard and connect the Green Wire Terminal and Black Wire Terminal of the Main Connector 20P 24P with the provided Jump Cable 5 Connect the DC Cable to the Power Terminal on the Reserator XT s back panel and connect the opposite 4 Pin Connector to the Power Supply s 4 Pin Connector 6 Supplying power to the Power Supply will light up the Red LED on the front panel cause the Flow Indicator s Impeller to rotate and the Blue LED on the side panel to light up For discharging of the gas
3. observed please check if there are any mechanical or pump related problems 2 FND Flexible Numeric Display Display Temperature Display Coolant Temperature upper display Ambient Temperature lower display Coolant Level Sensing If a certain quantity of coolant is unavailable an alarm will sound and the display will flicker If the flickering is observed please refill with coolant Coolant Temperature Sensing If the coolant s temperature reaches 60 C 92 F and above an alarm will sound and the FND Display will flicker If the flickering is observed please check if there are any problems 3 Coolant Flow Rate Gage Displays the coolant flow rate If there is a problem the display will flicker If the flickering is observed please check if there are any mechanical or pump related problems 5 10 Front Panel Display HYBRID LIQUID COOLING SYSTEM RESERATOR XT O TEMP M AUTO MANUAL LED RESET Control Knob amp Buttons Control Knob Controls the Fan Speed rpm and Coolant Flow Rate C F Button Sets the temperature display to Celsius C or Fahrenheit F AUTO MANUAL Button AUTO Mode Automatically adjusts fan speed and coolant flow rate MANUAL Mode Allows the user to manually adjust fan speed and coolant flow rate LED RESET Button LED On Off Short pressing of the button turns the displays LEDs On amp Off RESET Pressing the button for at least 5 seconds will
4. purchase 7 Separate the Reserator from the PC case when moving the system 8 Do not block the Air Ducts on either side of the product with any object It could lead to fan failure increased noise or a decrease in product performance 9 Make sure that the Water Pump is functioning properly Visit our website www zalman co kr and watch the Reserator XT installation video for an installation overview Disclaimer Zalman Tech Co Ltd is not responsible for any damages due to external causes including but not limited to improper use problems with electrical power accident x Please read this manual thoroughly before installation neglect alteration repair improper installation or improper testing x The specifications of this product and its components may change without prior notice to improve performance cations of this product and its components may change without prior notice to improve performance The specifications of this product and its components may change without prior notice to improve Table of Contents Installation and Operational Notes See ee E E ee ee 3 D SOG iICALIONIS mul ken 5 gt installation CWA Tg seer ts face cise a ens nee dee eee eco niceee soe 6 4 Olli Mee ee ea en ee 1 E ihetalaion Gude ee ee 8 6 OplicnalProdueie ee sung een 17 High Performance Ultra Quiet Water Cooling System e Active Passive Hybrid Cooling Design Active Cooling 140mm Fan Forced Convection Cooling Pas
5. reset the Reserator XT The specifications of this product and its components may change without prior notice to improve performance 6 6 The specifications of this product and its components may change without prior notice to improve performance Zalman Noise Prevention System Stable performance and noiseless liquid cooling system can both be achieved with the use of Zalman s Noiselee Power Supply VGA Water Block Northbridge Water Block VGA RAM Water Block Noiseless VGA Water block Northbridge VGA RAM Water Block Power Supply Water Block Heatpipe Cooled Modular Power Supply i i ZM500 HP ZM600 HP Reduction in the PFC circuitry s switching FET heat generation by use of 3 Parallel switching FETs normally 1 or 2 used Heatpipe cooling system on the main rectifier output diodes for maximum stability and minimum fan speed for ultra quiet operation Modular design for convenient and tidy cable installation Blue LEDs for cool aethetics Gaming PC Enclosures High end Gaming Enclosure built sturdy all aluminum aanels Three tool free hinged magnetic panel 2 Left 1 Right for easy installation and access to com ponents Tool free installation of disk drives Fan Controllers Audio interfaces etc Accommodates up to 6 Hard Drives Luxurious and cool aesthetics Color option Black Red LED Fans Titanium Blue LED Panel For more information please visit our website
6. within the Reserator and good coolant circulation turn the Power Supply ON OFF approximately 3 7 times in 10 second intervals 7 Circulate the coolant for approximately 10 minutes for leakage inspection and for checking its operation then turn OFF the Power Supply Disconnect the Degassing Tube and disassemble the Quick Coupling Inserts from the Degassing Tube Note 1 Make sure that the coolant of the Reservoir does not overflow when tilting the unit Note 2 Check the degassing status by looking at the tubes Once degassing is complete turn the PC OFF and install the Water Blocks Note 3 If the Flow Indicator detects a problem with coolant circulation an alarm will sound and the red LED will begin to flicker Press the Light Reset button for 5 seconds to restart the sysiem The specifications of this product and its components may change without prior notice to improve performance 4 Pin Connector Main AI Connector Hy oo M Board Jump Cable DC Cable Flow indicator The specifications of this product and its components may change without prior notice to improve performance w 5 4 CPU Water Block Installation ZM WB5 1 Refer to the manual provided with the ZM WB5 for installation 2 If interference occurs while installing the Water Block then stop the installation 5 5 CPU Water Block and Reserator s Base IN Connection 1 Connect one end of the PVC Tube to the Fit
7. Computer Enclosure RESERATOR XT User s Manual English Version COOL INNOVATIONS Installation and Operational Notes Installation Notes 1 Do not place the unit in dusty or humid conditions under direct sunlight or near a heat source such as a room heater 2 Do not drop or subject the unit to excessive force 3 Check the CPU socket compatibility before installation 4 Do not mix any contaminants with the coolant when filling It may cause product failure or corrosion 5 Place the unit on top ofthe PC or a location with good ventilation Check for leaks on the Water Blocks and Tubes before installation n g l IS h Ve rs 0 n 7 Preparing the necessary tools Needle Nose Pliers Scissors will ease the installation process Operational Notes O 1 Check to see if the DC cables are properly connected before use 2 If the coolant is not circulating properly or if the pump s flow rate becomes too low for other reasons then the red LED will begin to flicker with an alarm sound Immediately turn the PC OFF and contact the place of purchase 3 Do not place any objects on the product 4 Install the unit on a leveled surface free of vibration and do not tilt or lay the unit on its side while using 5 Must use the provided coolant Regularly check the amount of coolant and replenish as needed must be with new coolant every year 6 If a leak is found turn off the system immediately and contact the place of
8. PVC Tube 4m Ense placement The Reserator s placement 2 should be determined in relation I 1 to the position of the PC Place it O O upright next to or slightly above 7 VO Bracket 1EA the PC Note that if the Reserator is placed lower than the PC the PVC Tube s internal air pressure may prevent proper initial operation 5 2 Adding Coolant 1 Remove the Reserator XT s Reservoir Cap by turning it counter clockwise 2 Mix the provided coolant with one liter of distilled water in a bowl 9 Tube Clamp 2EA 3 The entry hole is small Therefore use the provided coolant container to fill the Reserator with mixed coolant four separate pours for a sum of 1000m 4 Jump Cable 1EA Note 1 Fill by four separate pours to prevent overflowing of coolant Once air has been completely 10 User s Manual 1EA released and the coolant begins to circulate then refill the remaining coolant 250m Note 2 The provided coolant is a concentrated liquid Therefore it must be diluted with distilled water in a 1 4 ratio Note 3 Read the warning label on the coolant before use Note 4 Keep this product and its associated system away from children 5 Coolant ZM G300 1EA w The specifications of this product and its
9. ck wire terminal of the Power Supply s Main Connector are connected with the Jump Cable 2 Check the amount of coolant inside the Reserator s Reservoir and fill it by approximately 80 3 Connect the Power Supply s 4 Pin Connector to the Reserator s DC Cable Connector and provide power for the Power Supply 4 Once power is supplied check to see if the Flow Indicator s impeller placed inside the Reserator s side panel is rotating if the blue LED is lit and if the coolant is being circulated to each Water Block 5 Check for leakage at each connector Leakage can lead to short circuits and damage the motherboard or other components If leakage is found turn OFF the power completely remove the water and reassemble the leaking section 6 If there is no leakage remove the Power Jump Cable from the Power Supply s Main Connector Now connect the Power Supply s Main Connector to the motherboard s Power Connector and run the PC Reserator XT body e l Note 1 Power must be supplied to the Reserator s DC Cable at all times for the Reserator and the PC to run simultaneously The user must check periodically to see if the DC Cable is connected properly The specifications of this product and its components may change without prior notice to improve performance o amp Front Panel Display 1 Fan Speed Gage Displays the Fan Speed rpm If there is a problem the display will flicker If the flickering is
10. ector Slowly connect with both hands d Cord Bushing Ar Bolt NE Connector DC Cable Connector lt Installation of Optional Products gt VGA Water Block Installation PVC Tube Connect the CPU Water Block and the VGA Water Block with the PVC Tube and fasten them with Tube Clamps as shown in the diagram Note 1 Using Needle Nose Pliers for fixing the Tube Clamps in place will make the installation easier VGA Water Block and Reserator s Base IN Connection Water Block 1 Connect one end of the PVC Tube to the Fitting of the VGA Water Block and fasten with a Tube Clamp as shown in the diagram 2 Pull out the PVC Tube through the I O Bracket hole on the computer case 3 Connect the Quick Coupling Insert that has been disconnected from the Degassing Tube to the other end of the PVC Tube and fasten it with a Tube Clamp 4 Plug the Quick Coupling Insert into the Quick Coupling Socket of the Base IN fitting Base IN Quick Coupling Body The specifications of this product and its components may change without prior notice to improve performance 2 CPU Water Block and Reserator s Base OUT Connection 1 Connect one end of the PVC Tube to the Fitting of the CPU Water Block and fasten with a Tube Clamp as shown in the diagram 2 Pull out the PVC Tube through the I O Bracket hole on the computer case 3 Connect the Quick Coupling Inse
11. ft 1 8m Dt Nut Dt SA 2 2 CPU Water Block ZM WB5 1 Weight 160g 2 Materials Base Cover Pure Aluminum Base Pure Copper 3 Dimensions 63 W x 63 L x 40 H mm 2 3 Anti Corrosion Coolant ZM G300 1 Materials Propylene Glycol amp Anti Corrosion Agent 2 Volume 250m 3 Freezing Point 9 C 4 Exchange Cycle 1Year Dt Dt tt SA lt Optional Components gt 2 m EY 2 4 VGA Water Block ZM GWB3 GWB8800 Ultra amp GTX GTS GT 1 Weight 100g 420g Z 2 Materials Anodized Pure Aluminum an 0 3 Dimensions 60 4 L x 60 4 W x 30 H mm 183 w x 95 L x 30 H mm 4 Compatible VGA Cards All VGA cards with installation holes m m u 2 5 Northbridge Water Block ZM NWB1 1 Weight 48g 2 Materials Anodized Pure Aluminum 3 Dimensions 43 W x 43 L x 30 H mm IN Terminal J OUT Terminal 2 6 VGA RAM Water Block ZM RWB1 1 Weight 120g 2 Materials Anodized Pure Aluminum 3 Dimensions 19 W x 122 L x 12 H mm decifications of this product and its components may change without prior notice to improve performance e The specifications of this product and its components may change without prior notice to improve per 4 Components r 5 Installation Guide r i e0e 1 Reserator XT 1 Unit 6
12. num plastic and other metals that prevents corrosion for long term operation 3 FND Flexible Numeric Display Displays the internal temperature water temperature water level and mode The black background and wine color details intensify the aesthetics 4 Analog Gauge Displays the fan speed and pump s flow rate The wine colored lighting adds a touch of elegance and tuning effect 5 Automatic Control The internal coolant temperature sensor automatically regulates the fan speed and coolant flow rate for optimal cooling and ultra quiet operation 6 Flow Indicator This component is connected with the circulation tube for checking the circulation of the coolant When the coolant is circulating properly its impeller rotates to visually indicate the status of coolant flow 7 Quick Coupling The Fittings incorporate valves that prevent leaks when disassembling the Reserator allowing quick and convenient separation and reassembly of the Reserator for transport and coolant replacement The specifications of this product and its components may change without prior notice to improve performance 2 Specifications 3 Installation Overview 2 1 Reserator XT Reservoir Radiator Water pump 1 Weight 7kg 2 Materials Anodized Pure Aluminum 3 Dimensions 350 L x 210 W x 180 H mm I 4 4 Maximum Coolant Capacity Max 1 25 N CPU WATER BLOCK 5 Integrated Water Pump 6W DC 12V 300L Hr U 6 Maximum Li
13. rt that has been disconnected from the Degassing Tube to the other end of the PVC Tube and fasten it with a Tube Clamp 4 Plug the Quick Coupling Insert into the Quick Coupling Socket of the Base OUT fitting Ss SAIS Tas Quick Coupling Insert Northbridge Water Block Installation 1 When using the Northbridge Water Block please install as illustrated below 2 The Tube Clamps must be installed on the PVC Tubes CPU Water Block Tube Clamp Northbridge Water Block VGA Water Block VGA RAM Water Block Installing z CPU Water Block 1 When using the VGA RAM Water LE VGA RAM Block please install as illustrated in Water Block the diagram 2 The Tube Clamps must be installed on the PVC Tubes 3 VGA Water Block B e The specifications of this product and its components may change without prior notice to improve performance 5 8 Confirmation of Proper Installation 1 Check if the product is placed properly 2 Check if the coolant s circulation path conforms to the path shown below 3 Slightly tug on the PVC Tubes connected to each Fitting to check for loose connections Reserator OUT gt CPU Water Block 4 mei N B Water Block lt OPTION gt 4 Radiate Absorb gt Heat nea VGA Water Block lt OPTION gt Bd 4 RAM Water Block dm Reserator IN lt lt OPTION gt 5 9 Leakage Inspection and Test Run 1 Check to see if the green wire terminal and the bla
14. sive Cooling Anodized Aluminum Heatsink Chassis Natural Convection Cooling e Automatic Manual Control Modes Automatic Mode Coolant Temperature is monitored for Automatic Control of Fan Speed and Coolant Flow Rate Manual Mode Front Panel Control Knob allows the user to manually optimize performance and minimize noise e Warning amp Alarm System Coolant Flow Monitoring Warns the user when coolant flow is problematic Coolant Level Monitoring Warns the user when the coolant level is low e Comprehensive Visual Monitoring Display Coolant Temperature viewable in C or F Ambient Temperature viewable in or F Coolant Level Warning Icon Lights Up When Coolant Level Is Low e Coolant Flow Rate Coolant Flow Indicator Light Switch e Automatic Power ON OFF In Sync with the Computer e Quick Couplings for Fast Convenient and Leak Free Installation amp Maintenance The specifications of this product and its components may change without prior notice to improve performance 1 CPU Water Block ZM WB5 The CPU Water Block incorporates a pure copper base for excellent heat transfer The Water Block Cover has been anodized to prevent corrosion It supports Intel s Socket 775 CPUs and AMD s Socket 754 939 940 AM2 CPUs and is designed to be light weight and easy to install 2 Anti Corrosion Coolant ZM G300 This coolant contains a high quality anti corrosion agent for various materials including copper alumi
15. ting of the CPU Water Block and fasten with a Tube Clamp as shown in the diagram 2 Pull out the PVC Tube through the I O Bracket hole on the computer case 3 Connect the Quick Coupling Insert that has been disconnected from the Degassing Tube to the other end of the PVC Tube and fasten it with Tube Clamp 4 Plug the Quick Coupling Insert into the Quick Coupling Socket of the Base IN fitting Base IN Quick Coupling Body 5 6 CPU Water Block and Reserator s Base OUT Connection 1 Connect one end of the PVC Tube to the CPU Water Block Fitting and fasten with a Tube Clamp as shown in the diagram 2 Pull out the PVC Tube through the tube hole of the I O Bracket 3 Connect the Quick Coupling Insert to the other end of the PVC Tube and fasten with a Tube Clamp 4 Plug the Quick Coupling Insert into the Quick Coupling Socket of the Base OUT fitting F CE dl Base OUT Quick Coupling Body on e The specifications of this product and its components may change without prior notice to improve performance 5 7 DC Power Cable Connection 1 Fit the DC Cable s Cord Bushing into the groove of the I O Bracket and fasten the I O Bracket with a Bolt 2 Connect the DC Cable Connector to the 4 Pin Connector of the Power Supply Note 1 Do not exert excessive force when connecting the conn
Download Pdf Manuals
Related Search
Related Contents
FT=2400Η 取扱説明書 コンビ ニンナナンナ マジカルコンパクトファースト SK SimNow User Manual RAS Plus Benjamin - PublicationsList.org 2004 Minute Service Manual VocALign Project 3 AU Manual inattention lors de l`installation du passager. Copyright © All rights reserved.
Failed to retrieve file